MyFAST 4.0

download MyFAST 4.0

of 6

Transcript of MyFAST 4.0

  • 8/2/2019 MyFAST 4.0

    1/6

    BIO-MICROBICS 2010 3/27/2009

    WEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED

    CTC

    MyFAST 4.0

    REVISED 5/25/2010PF

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    S IZE DRAWING NUMBER

    ANAME DATE SHEET1 OF 6

    lbWEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED PF

    LayoutINI-02-M

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    NAME DATE

    5/25/2010 REV.

    lb

    MyFAST 4.0(4) 1618 SaniTEE ScreensBlowers and BlowerHousingsCentral Control PanelBiosolids collection piping(4) MyFAST Segments

    OPTIONAL MyFAST 4.0 BMS(Biosolids Management System)

    Sludge PumpDecant PumpLIXOR 2.0Jib Crane

    NOTES:

    The air supply line into the1.FAST unit must be securedso as to prevent damagefrom pipe vibration.The units are supplied with2.3" semi-flexible airlineconnections with stainlesssteel MPT fittings.Each blower will require 4"3.steel pipe to connect to thedistributed airlift system.Influent pipe shall be4.positioned to maximizesettling. A prescreeningdevice may be utilizedbased on the individual siteconditions andcharacteristics of theinfluent.

    Biosolids Pump Pit

    BiosolidsCollection

    FASTBlower

    LIXOR 2.0 Biosolids release toDewatering Stationprovided by others

    6" PVCOutlet

    Airlines

    InfluentSee note 4

    6" PVCOutlet

    EffluentCollection Pipe

    SettlingZone

    TreatmentZone

    Biosolids Storage Zone

    Lateral Braceby others

    1618 SaniTEEScreens

    36

    91.44

    Overflow fromBiosolids storage

    Decant pump

    97 MIN246 MIN

    11.7 PVC Lengthbased on MIN Outlet height

    29.7

  • 8/2/2019 MyFAST 4.0

    2/6

    90 MAXBioSolids Water Level

    229 MAX

    BIO-MICROBICS 2010 3/27/2009

    WEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED

    CTC

    MyFAST 4.0

    REVISED 5/25/2010PF

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    S IZE DRAWING NUMBER

    ANAME DATE SHEET2 OF 6

    lbWEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED PF

    Tank DetailsINI-01-Q

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    NAME DATE

    5/25/2010 REV.

    lb

    36 MIN

    91 MIN

    820

    104264

    97.0 MIN246 MIN

    8 PVC Pipe

    23 MIN Freeboard58 MIN

    104 MIN264 MIN

    97 MIN246 MIN

    3179

    74188

    117

    297160406

    1230 8

    20.3

    6 PVC Pipeopening

    76.75

    Emergency overflow

    from Biosolids Storage Zone

    Biosolids release toDewatering Station

    Biosolids PumpPit

    Influent

    16" SaniTEEScreen placement

    Biosolids Storage Zone8400 Gallon MIN[32 m3 MIN]

    Settling Zone20,000 Gallon MIN[76 m3 MIN]

    Treatment Zone40,000 Gallon MIN[151 m3 MIN]

    40010

    101525

    36 MIN

    91 MIN

    30 MIN76 MIN

    234559413

    453.6010.00115225

    48 MIN122 MIN

    186.0 MIN

    472.44 MIN

    31 MIN78.74 MIN

  • 8/2/2019 MyFAST 4.0

    3/6

    BIO-MICROBICS 2010 3/27/2009

    WEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED

    CTC

    MyFAST 4.0

    REVISED 5/25/2010PF

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    S IZE DRAWING NUMBER

    ANAME DATE SHEET3 OF 6

    lbWEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED PF

    Biosolid CollectionINI-01-I

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    NAME DATE

    5/25/2010 REV.

    lb

    Notes:Biosolids Collection Supplied by Bio-Microbics1.Secure Biosolids Collection grid every 36" [90cm]2.

    378959

    6 PVC Elbow

    8 PVC TEE

    6 PVC TEE

    8" PVC piping byothers connectssludge pump pitto collectionpiping

    6 PVC Pipe

    8 PVC Pipe

    63.51601

    61.51551

    63.5

    1601

  • 8/2/2019 MyFAST 4.0

    4/6

    Notes:Secure leg extension to the FAST unit by placing two1.screws on each side of the leg extension (4 screws per footare included).To obtain the desired height of leg cut 4" [10] schd. 40 PVC2.pipe (not included). Minimum pipe length of 11 1/8" [28.26];For heights greater then 18" [45.7] use schd. 80 PVC pipe(not included). Consult factory for extending leg beyond

    36"[91].Anchor the leg extensions to the tank with non-corrosive3.hardware (not included) at the provided mounting points.Tank, anchors, piping conduit, blower, housing pad and4.vents are provided by others.LIXORs must be spaced in Biosolids Storage Zone for5.maximum mixing and aeration. Consult Bio-Microbics.Sludge pump discharge piping must create at least 22'6.[6.7m] of TDH at 60 Hz and 8' [2.4m] of TDH at 50 Hz.Decant pump discharge piping must create at least 22'7.[6.7m] of TDH at 60 Hz and 8' [2.4m] of TDH at 50 Hz.

    BIO-MICROBICS 2010 3/27/2009

    WEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED

    CTC

    MyFAST 4.0

    REVISED 5/25/2010PF

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    S IZE DRAWING NUMBER

    ANAME DATE SHEET4 OF 6

    lbWEIGHT

    DO NOT SCALE

    UNLESS NOTEDDIMENSIONSARE IN INCHES[CENTIMETERS]TOLERANCES 0.02 IN/IN[ 0.05 CM/CM]

    DRAWN

    CHECKED PF

    DetailsINI-05-K

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTS ARE RESERVED. IN THEINTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

    NAME DATE

    5/25/2010 REV.

    lb

    Minimum legextension assembly

    See Note 2 & 3

    2 screws per side includedSee Note 1

    12 MIN29.72 MIN

    Decanting PumpSee note 7

    Jib crane

    Return toTreatmentZone

    BiosolidsPumpOutlet

    OPTIONAL DIGEST ZONE

    LIXOR2.0

    BiosolidsPumpSee note 6

    See Note 5

    3" MIN air supply lineutilizing galvanized orstainless steel pipingfrom the blower housing

    to the treatment tankprovided by others.

    Concrete base

    provided byothers

    Electrical conduitto Bio-Microbicscontrol panel

    provided by others

    35

    36

    57

  • 8/2/2019 MyFAST 4.0

    5/6

  • 8/2/2019 MyFAST 4.0

    6/6