Structural Analysis And Design of Multi-storeyed Building
Project members:
Rajesh Dhakal (066/BCE/57)
Sandeep Shrestha (066/BCE/70)
Santanu Shrestha (066/BCE/73)
Shyam Kumar Sinkemana (066/BCE/80)
Supervisor:Asst. Prof. Prachand Man Pradhan
![Page 2: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/2.jpg)
Objectives
• Learn the concept of lateral and vertical loading on the building.
• Identification of structural arrangement of the plan.
• Modeling of the building for the structural analysis.
• Detail structural analysis using SAP 2000.• Sectional design of structural components.• Structural detailing of members and the system.
![Page 3: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/3.jpg)
Major Scope
• Seismic coefficient method is used• Code of practices: IS456:2000, IS875:1987(Part
1,2), IS1893:2000, IS13920:1993, SP16,SP34• The bearing capacity of foundation is assumed
to be 140 kN/m2.• The project does not take into account the soil
pressure in elements at the basement as well as the possible impact loads due to vehicles
![Page 4: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/4.jpg)
Salient Features
• Name: Bharbhacho Complex• Location: Dhudhpati, Bhaktapur• Building Type: Commercial• System: RCC framed Structure• No. of storeys: 7• Floor ht: 3.3m• Foundation type: Raft foundation
![Page 5: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/5.jpg)
Preliminary Design
• Design of Slab :
as per deflection control
Slab Depth Effective depth (d) Total depth (D)
Without secondary beam
190 mm 220 mm
With secondary beam
120 mm 150 mm
![Page 6: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/6.jpg)
Design of beam:as per deflection control
Beam type Width (b) Total depth (D)
Primary Beam 400 mm 550 mm
Secondary beam 250 mm 300 mm
![Page 7: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/7.jpg)
• Design of column– Loaded from slab, wall, beam and self weight of
column considered– Factored load calculated– 20% EQ load considered– Equating total load with Puz=0.45fckAc+0.75fyAst
– Assuming Pt=3%
– Ag calculated and size of column adoptedColumn Type Dimension (B×D) mm2
Type I 400×400Type II 400×400Type III 500×500
![Page 8: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/8.jpg)
Manual calculation
• Dead Load– Slab– Beam– Wall– column
• Live load• Centre of mass• Centre of rigidity• Eccentricity
![Page 9: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/9.jpg)
SAP Analysis
![Page 10: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/10.jpg)
Design of Structural members
• Design of Slab
Xm Ym Xs Ys
Ast required
112.25 98.04 141.51 132.27
Ast provided
452.36 376.967 376.967 376.967
![Page 11: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/11.jpg)
Slab Detailing
![Page 12: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/12.jpg)
Torsional Detail in Slab
![Page 13: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/13.jpg)
Design of Staircase
StaircaseMain reinforcement Distribution bar Development length
Required Provided Required Provided Required Provided
Doglegged 12Φ 559c/c 12Φ 200 c/c 8 Φ@279c/c 8 Φ@270c/c 810 mm 820 mm
Openwell1st flight
12Φ391.65c/c
12Φ300 c/c 8 Φ@279c/c 8 Φ@270c/c 483 mm 485 mm
2nd flight 12Φ398.26 c/c
12Φ195c/c 8 Φ@279c/c 8 Φ@270c/c 600 mm 700 mm
![Page 14: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/14.jpg)
Staircase Detailing
![Page 15: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/15.jpg)
![Page 16: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/16.jpg)
![Page 17: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/17.jpg)
Design of Beam Beam Type
Support reinforcement Mid reinforcement
Top bar Bottom bar Top bar Bottom bar
Primary beam (400x550) 5-25 Φ 4-20 Φ 2-20 Φ 2-25 Φ
Stair beam (400x 550) 2-20 Φ 2-20 Φ 2-20 Φ 4-20 Φ
Secondary beam (250x300) 3-16 Φ 2-16 Φ 2-16 Φ 3-16 Φ
![Page 18: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/18.jpg)
Beam Detailing
![Page 19: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/19.jpg)
Contd.
![Page 20: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/20.jpg)
Design of ColumnColumn Types Reinforcement percent
Small (400x400) 8-28 Φ 2.43 %
Big (600x600) 12-25 Φ 1.64 %
Ramp (500x600) 12-28 Φ 2.46 %
![Page 21: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/21.jpg)
Column Detailing
![Page 22: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/22.jpg)
![Page 23: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/23.jpg)
Design of Basement wall
Reinforcement pattern Face ReinforcementVertical Both 16 mm Φ @ 190 mm
HorizontalFront 8 mm Φ @160 mmInner 8 mm Φ @320mm
![Page 24: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/24.jpg)
Detailing of Basement wall
![Page 25: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/25.jpg)
Design of Lift
Lift TypesVertical Reinforcement Horizontal Reinforcement
Required Provided Required Provided
Capsule 14 Φ @ 109.36 14 Φ @ 100 12 Φ @ 253.85 12 Φ @ 250
Middle capsule 14 Φ @ 331.14 14 Φ @ 320 12 Φ @ 253.85 12 Φ @ 250
Service 14 Φ @ 367.67 14 Φ @ 350 12 Φ @ 253.85 12 Φ @ 250
![Page 26: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/26.jpg)
Lift Detailing
![Page 27: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/27.jpg)
Design of FoundationShorter span reinforcement Longer span reinforcement
20 mmφ @ 175 mm c/c 20 mmφ @ 200 mm c/c
![Page 28: multistorey building design by sap and autocad](https://reader033.fdocuments.net/reader033/viewer/2022061116/54658e77af795939528b7971/html5/thumbnails/28.jpg)
Raft Footing Detailing