![Page 1: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/1.jpg)
MULTITESTER
SYSTEMS PLUS COMPUTER COLLEGE
“Commitment to Excellence”
![Page 2: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/2.jpg)
ANALOG MULTITESTER
2 KINDS OF MULTITESTER
SYSTEMS PLUS COMPUTER COLLEGE
“Commitment to Excellence”
![Page 3: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/3.jpg)
DIGITAL MULTITESTER
2 KINDS OF MULTIESTER
SYSTEMS PLUS COMPUTER COLLEGE
“Commitment to Excellence”
![Page 4: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/4.jpg)
MULTIMETERIs an indispensable for a technician as firearms for aSoldier. The interpretation of readings gives technicianClues to trouble-shooting.
SYSTEMS PLUS COMPUTER COLLEGE
“Commitment to Excellence”
![Page 5: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/5.jpg)
Zero ohms adjustments:
Use to set the pointer exactlyOn zero position at the right side of meter panel
![Page 6: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/6.jpg)
Zero corrector:
Use to set the meter pointer toZero position at the left side ofThe meter panel
![Page 7: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/7.jpg)
Range selector:
It is used to adjust the proper Function range for specific measurement
![Page 8: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/8.jpg)
Dial pointer
![Page 9: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/9.jpg)
Dial scale:
![Page 10: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/10.jpg)
DC voltagerange
Voltmeter: is an instrument is usedMeasuring voltage or potential difference
Observed polarity in measuringDC voltage and current.
Always set at higher range of meter
SYSTEMS PLUS COMPUTER COLLEGE
![Page 11: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/11.jpg)
AC voltage range
1. Before taking a measurement,the pointer position should beconfirmed to zero on the top ohm scale.
2. With the + and – COM terminalsshorted together, the meter isadjusted by turning the zeroohm adj. to the right or left inorder to place on zero at right.
3. Always set the meter pointer onthe highest range of therefunction, if measuring an unknownvoltage or current.
SYSTEMS PLUS COMPUTER COLLEGE
![Page 12: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/12.jpg)
Resistance
Ohmmeter : is an instrumentUsed for measuring resistance.
Always remember the:
1. Zero ohms adjustment2. Zero corrector
![Page 13: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/13.jpg)
Test probe+ & -
SYSTEMS PLUS COMPUTER COLLEGE
![Page 14: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/14.jpg)
Dial scale
Zero corrector
AC voltage range
Dial selector
resistanceTest prove/socket
DC voltage
Zero ohmsadjustment
Dial pointer
Front panel
PARTS OF MULTITESTER
![Page 15: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/15.jpg)
Voltmeter:
Is used when it is necessary to determine thepresence or absence of an electrical pressure or voltage on a unit under test.
Tester has two voltmeter functions:
1. AC or alternating current
2. DC or Direct current
SYSTEMS PLUS COMPUTER COLLEGE
“Commitment to Excellence”
![Page 16: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/16.jpg)
DC VOLTMETER:
1. When operating on .1 volt range, we utilize the 10 volts scale and Shift the decimal two places to the left. (.01 as multiplier )
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
![Page 17: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/17.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DC VOLTMETER:
2. If the instrument is operated on 0.5 v range, we utilize the 50 vscale and move the decimal point two places to the left.(.01 as multiplier )
![Page 18: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/18.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DCV/2.5DCV/2.5 0-2500-250 110110 .01.01 1.101.10
DC VOLTMETER:
3. When VOM is set to 2.5 v range, we use the 250 v scale and shiftthe decimal point two laces to d left ( .01 as multiplier )
![Page 19: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/19.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DCV/2.5DCV/2.5 0-2500-250 110110 .01.01 1.101.10
DCV/10DCV/10 0-100-10 4.44.4 11 4.44.4
DC VOLTMETER:
4. VOM is operated on 10 v range, we utilize the 10 v scale and read directly or set 1 as multiplier
![Page 20: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/20.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DCV/2.5DCV/2.5 0-2500-250 110110 .01.01 1.101.10
DCV/10DCV/10 0-100-10 4.44.4 11 4.44.4
DCV/50DCV/50 0-500-50 2222 11 2222
DC VOLTMETER:
5. VOM is operated on 50 v range, we utilize the 50 v scale and read directly or set 1 as multiplier
![Page 21: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/21.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DCV/2.5DCV/2.5 0-2500-250 110110 .01.01 1.101.10
DCV/10DCV/10 0-100-10 4.44.4 11 4.44.4
DCV/50DCV/50 0-500-50 2222 11 2222
DCV/250DCV/250 0-2500-250 110110 11 110110
DC VOLTMETER:
6. VOM is operated on 250 v range, we utilize the 250 v scale and read directly or set 1 as multiplier
![Page 22: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/22.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DCV/2.5DCV/2.5 0-2500-250 110110 .01.01 1.101.10
DCV/10DCV/10 0-100-10 4.44.4 11 4.44.4
DCV/50DCV/50 0-500-50 2222 11 2222DCV/250DCV/250 0-2500-250 110110 11 110110DCV/1000DCV/1000 0-100-10 4.44.4 100100 440440
DC VOLTMETER: 7. VOM is operated on 1000 v
range, we utilize the 25 v scale andshift decimal point two places to d right ( 100 as multiplier )
![Page 23: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/23.jpg)
Range usedRange used Scale usedScale used Scale readingScale reading multipliermultiplier Actual readingActual reading
DCV/0.1DCV/0.1 0-100-10 4.44.4 .01.01 0.440.44
DCV/.5DCV/.5 0-500-50 2222 .01.01 0.220.22
DCV/2.5DCV/2.5 0-2500-250 110110 .01.01 1.101.10
DCV/10DCV/10 0-100-10 4.44.4 11 4.44.4
DCV/50DCV/50 0-500-50 2222 11 2222
DCV/250DCV/250 0-2500-250 110110 11 110110DCV/1000DCV/1000 0-100-10 4.44.4 100100 440440
DC VOLTMETER
![Page 24: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/24.jpg)
AC VOLTMETER READING
![Page 25: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/25.jpg)
Range Range usedused
Scale Scale usedused
Scale Scale readingreading
multipliermultiplier Actual Actual readingreading
ACV/10ACV/10 0-100-10 2.42.4 11 2.42.4
ACV/50ACV/50 0-500-50 1212 11 1212
ACV/250ACV/250 0-2500-250 6060 11 6060
ACV/1000ACV/1000 0-100-10 2.42.4 100100 240240
AC VOLTMETER READING CHART
![Page 26: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/26.jpg)
DC CURRENT METER
![Page 27: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/27.jpg)
RANGE RANGE USEDUSED
SCALE SCALE USEDUSED
SCALE SCALE READINGREADING
MULTIPLIERMULTIPLIER ACTUAL ACTUAL READINGREADING
DCA/50 UADCA/50 UA 0-500-50 3232 11 32UA32UADCA/2.5MADCA/2.5MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/25 MADCA/25 MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/.25ADCA/.25A 0-2500-250 160160 .001.001 .16A.16A
1. 50 Micro ampere range, we utilize the 50 v scale and read directly
![Page 28: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/28.jpg)
RANGE RANGE USEDUSED
SCALE SCALE USEDUSED
SCALE SCALE READINGREADING
MULTIPLIERMULTIPLIER ACTUAL ACTUAL READINGREADING
DCA/50 UADCA/50 UA 0-500-50 3232 11 32UA32UA
DCA/2.5MADCA/2.5MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/25 MADCA/25 MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/.25ADCA/.25A 0-2500-250 160160 .001.001 .16A.16A
2. To read current in the 2.5ma range, read the 0-250and move decimal point to places to d left
![Page 29: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/29.jpg)
RANGE RANGE USEDUSED
SCALE SCALE USEDUSED
SCALE SCALE READINGREADING
MULTIPLIERMULTIPLIER ACTUAL ACTUAL READINGREADING
DCA/50 UADCA/50 UA 0-500-50 3232 11 32UA32UA
DCA/2.5MADCA/2.5MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/25 MADCA/25 MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/.25ADCA/.25A 0-2500-250 160160 .001.001 .16A.16A
3. Move decimal point just once to the left
![Page 30: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/30.jpg)
RANGE RANGE USEDUSED
SCALE SCALE USEDUSED
SCALE SCALE READINGREADING
MULTIPLIERMULTIPLIER ACTUAL ACTUAL READINGREADING
DCA/50 UADCA/50 UA 0-500-50 3232 11 32UA32UA
DCA/2.5MADCA/2.5MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/25 MADCA/25 MA 0-2500-250 160160 .01.01 1.6MA1.6MA
DCA/.25ADCA/.25A 0-2500-250 160160 .001.001 .16A.16A
4. Move decimal point 3 places to d left
![Page 31: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/31.jpg)
SYSTEMS PLUS COMPUTER COLLEGE
“Commitment to Excellence”
Testing voltage:
From battery whichIs a DC voltage
![Page 32: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/32.jpg)
![Page 33: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/33.jpg)
PARTS OF MULTITESTER
1
2
34
5
6
7
8
910
![Page 34: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/34.jpg)
![Page 35: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/35.jpg)
![Page 36: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/36.jpg)
![Page 37: Multi Tester Parts & Uses](https://reader034.fdocuments.net/reader034/viewer/2022042518/553db8b0550346903b8b4760/html5/thumbnails/37.jpg)