Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase...

28
Multi Phase Meter Arvand Azin Aryan

Transcript of Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase...

Page 1: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Multi Phase Meter

Arvand Azin Aryan

Page 2: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Agenda• What is multiphase meter• Operating principle• Multiphase advantages• Fluid operation range• What companies using multiphase? • Operation example• Accessories List • Application data sheet• Third generation

Arvand Azin Aryan

Page 3: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

What is Multiphase meter?

The Multiphase meter Technology is the combination of the robust concept ofVenturi and well known and unique measurement of Multi-Energy

Gamma Ray to replace conventional well testing

Arvand Azin Aryan

Page 4: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Measures•fraction and velocity of oil•fraction and velocity of water•fraction and velocity of gas

Outputs•Oil rate•Water rate•Gas rate

Arvand Azin Aryan

Page 5: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Multiphase meter - Topside Arvand Azin Aryan

Page 6: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Multiphase meter - Topside

Arvand Azin Aryan

Page 7: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Gamma-rays detector

Ba133source

Venturi

Flow

ΔP

Venturi Total mass flow rate (Bernoulli)

Source and detector 3 phases fractions (nuclear attenuatio)

PVT model Convert from line to standard conditions

Output -> Oil, Gas, Water flowrates at standard conditions

Arvand Azin Aryan

Page 8: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

O

X

NNLn

d1

Qtotal mass = qtotal vol. * mixture = v * A * Mass Flow rate = (Volumetric Flow rate) (Mixture Density) = (Mixture Velocity ) (Venturi Throat Area) (Mixture) Density

liquid

waterwlrWLR

Arvand Azin Aryan

Page 9: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Principle of calculation

Arvand Azin Aryan

Page 10: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Page 11: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Venturi&

Delta PFluids

dynamics model

Total mass rate

Source & Detector Nuclea

r model

PhasesHold-ups

% Water% Oil

Gas Oil

Water

Single-phase rates

Fluids properties

model

Multiphase* Technology – Calculations overview

Arvand Azin Aryan

Page 12: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Technology Overview and advantages

• No phase separation,• No moving parts• No tuning factor, No flow calibration• WLR is not phase distribution dependent• Different sizes: 29, 52, 65, 88 (150 – 150,000

bpd)• No Sensor in direct contact with the fluid• Actual measurement at production conditions• Low Differential Pressure Design• No stabilization required• Compact Solution

Arvand Azin Aryan

Sep. 2015

Page 13: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Features and BenefitsOperation efficiency and safety

Compact, lightweight & small footprint Limited pressure test lines Simple equipment

mobilization

Reduced crew

Short operation duration, saving rig time and reducing flaring fast rig-up and rig down clean-up optimization no stabilization time

required

On line, continuous production monitoring

No moving part (low failure probability)

Data quality & Metrological performance

Improved accuracy vs. conventional testing

High repeatability

Independent of flow regimes

Exceptional dynamic response

Flow rate measurements during all clean-up

Early water detection

Not affected by slugs, foam and emulsion

Unique hardware for heavy oil, black oil, volatile oil, gas condensate, wet gas and dry gas well testing

Reduce the Operation cost

Arvand Azin Aryan

Page 14: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Fluid Range Operated up to nowArvand Azin Aryan

CP@ line conditions27000 1

Page 15: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Page 16: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Multiphase Connecting points from production line to test line

Inlet Manifolds of Wells

Arvand Azin Aryan

Page 17: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Deference in GVF and WLRH18 H8+H18

Arvand Azin Aryan

Page 18: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

H18

H18+H8

Arvand Azin Aryan

Page 19: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Well head parameters during the test

Arvand Azin Aryan

Page 20: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Deference in flow rates

H18 H8+H18

Arvand Azin Aryan

Page 21: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Results

We can subtract H8 oil Q=1761.9-1580=181.9 STB/d, gas Q=163.54-142.03=21.51 MScf/d, water Q=590.86-382.01=208.85 STB/d.

BSW=590.86/(590.86+163.54)=78%

Arvand Azin Aryan

Page 22: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Ratios

Arvand Azin Aryan

Page 23: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Well production

Operating point

Arvand Azin Aryan

Page 24: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Multiphase meter

Bypass manifold

Chock manifold

ESD panel

Gas manifold

Lab cabin

SSV

Data header

Pipes and elbows

Accessories List

Page 25: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Application data sheet

Page 26: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Third generation

Page 27: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Page 28: Multi Phase Meter Arvand Azin Aryan. Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using.

Arvand Azin Aryan

Address: Unit No. 11, No.17, Behruz St., Madar Sq., Mirdamad Ave., Tehran, IranTel: 021-22269805-6Fax: 021-22908234

Website: www.arvandazin.comEmail: [email protected]