Mt. Pleasant Library
-
Upload
jacksondcpl -
Category
Documents
-
view
708 -
download
4
description
Transcript of Mt. Pleasant Library
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant Library
Washington, DC 20010
3160 16th Street, NW
901 G Street, NW
Washington, DC 20001
N
0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Demolition
Terrace Floor Plan
- Plumbing
DP0.01
MEETING ROOM
BASEMENTLOBBY
STORAGE
BOILER ROOM
STORAGE
MEN'STOILET
WOMEN'STOILET
ELEVATORSHAFT
STORAGE
PROJECTIONROOM
ELEVATOR
LOBBY
MACHINE
ROOM
TO ACCESSIBLERAMP
STORAGE
STORAGE &
GROUNDSKEEPING
SECURITY
MECHANICAL
STORAGESHELVING
PLUMBINGJAN.
CLOS.
CLOS.
STORAGE
Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line
(E)
G
(E)
(E)
M
M
G
G
G
DRAWING NOTES:
1. REMOVE ALL EXISTING PLUMBING FIXTURES, FAUCETS, SUPPORTS AND APPURTENANCES IN THIS EXISTING TOILET ROOM.2. REMOVE EXISTING DOMESTIC WATER SERVICE MAINS AS INDICATED.3. REMOVE EXISTING SANITARY COMPLETELY BACK TO BUILDING SANITARY MAIN AT LOCATION
INDICATED. 4. REMOVE ALL EXISTING VENT PIPING TO PENETRATION THROUGH ROOF.5. REMOVE ALL EXISTING GAS SERVICE PIPING BACK TO METER AS INDICATED. THE CONTRACTOR SHALL
COORDINATE DEMOLITION OF EXISTING GAS SERVICE WITH GAS COMPANY. 6. REMOVE DISCONNECT AND REMOVE THE EXISTING GAS FIRED WATER HEATER AND ASSOCIATED WATER
AND GAS SERVICE PIPING AND VALVES. 7. EXISTING STORM DOWNSPOUT TO BE REMOVED.8. EXISTING STORM RISER TO REMAIN.
1
1
1
2
2
2
2
2
2
3
3
5
(E)
(E)
(E)
(E)
(E)
(E) (E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
6
(E) (E)
8
#
(E)
(E)
(E)
(E)
(E)
7
78
8
8
8
DEMOLITION TERRACE FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
1
DP0.01
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant Library
Washington, DC 20010
3160 16th Street, NW
901 G Street, NW
Washington, DC 20001
N
0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Demolition
First Floor Plan
- Plumbing
DP0.02
OPEN TO BELOW
OPEN TO BELOW
SPANISHROOM
REFERENCE
STORAGESHELVING
ADULTREADING AREA
FIRST FLOORLOBBY
STAFFROOM
ELECCLOSET
OFFICE
TOILET
COMPUTERSREADING AREA
STACKSAREA
UP
DN
UP
UP
MEZZANINE LEVEL
Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line
DRAWING NOTES:
1. REMOVE ALL EXISTING PLUMBING FIXTURES, FAUCETS, SUPPORTS, PIPING
AND APPURTENANCES IN THIS EXISTING TOILET ROOM.
2. EXISTING STORM DOWNSPOUT TO BE REMOVED.
3. EXISTING STORM RISER TO REMAIN.
1
#
3
2
23
3
3
3
DEMOLITION FIRST FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
1
DP0.02
DEMOLITION MEZZANINE FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
2
DP0.02
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WEREPREPARED OR APPROVED BY ME, AND THAT I AM ADULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant LibraryWashington, DC 200103160 16th Street, NW
901 G Street, NWWashington, DC 20001
N0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
DemolitionSecond Floor Plan- Plumbing
DP0.03
1-13-10 BID SET
ALCOVE 2
ALCOVE 1
CHILDREN'S READINGEXHIBITS AREA
LOBBY
MULTI-PURPOSEAREA
TEENAGER'SAREA/ COMPUTERS
ELEVATORLOBBY
LIBRARIAN
WORK ROOMCHILDREN'S
STACK ROOM
STAFFLOUNGE
STAFFTOILET
CHILDREN'STOILET
FIRST-AIDROOM
Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line
DRAWING NOTES:1. DEMO ALL EXISTING PLUMBING FIXTURES, FAUCETS, SUPPORTS, PIPING AND
APPURTENANCES IN THIS EXISTING TOILET ROOM.2. NOT USED.3. EXISTING STORM RISER TO REMAIN.
1
#
3
3
3
3
3
DEMOLITION SECOND FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
1
DP0.03
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WEREPREPARED OR APPROVED BY ME, AND THAT I AM ADULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant LibraryWashington, DC 200103160 16th Street, NW
901 G Street, NWWashington, DC 20001
N0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
DemolitionRoof - Plumbing
DP0.04
1-13-10 BID SET
Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line Property Line
1
1
1
1
1
DRAWING NOTES:1. APPROXIMATE LOCATION OF EXISTING STORM DOWNSPOUTS.
#
1
DEMOLITION ROOF PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
1
DP0.04
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant Library
Washington, DC 20010
3160 16th Street, NW
901 G Street, NW
Washington, DC 20001
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Plumbing
Data Sheet
P0.01
PLUMBING LEGENDABRV. DESCRIPTIONSYMBOL
SANITARY PIPINGSAN.,W.
STORM WATER PIPINGST ST
VENT PIPINGV
COLD WATER PIPINGCW
HOT WATER PIPINGHW
FIRE PIPING PROTECTION F F
SPRINKLER PIPINGSP SP
PUMP DISCHARGEPD PD
S#
SANITARY RISER DESIGNATION
RISER DESIGNATIONS
F#
FIRE RISER DESIGNATION
W#
DOMESTIC WATER RISER DESIGNATION
AFF ABOVE FINISHED FLOOR
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
ADA AMERICANS W/ DISABLITIES ACT COMPLIANCE
AHJ AUTHORITY HAVING JURISDICTION
ABV ABOVE
BLDG BUILDING
BLW BELOW
BTUH BTU PER HOUR
BTU BRITISH THERMAL UNIT
CLG CEILING
CONC CONCRETE
COL COLUMN
CI CAST IRON
DN DOWN
DWG DRAWING
DEG DEGREE
DIA DIAMETER
ELEC ELECTRICAL
EL ELEVATION
ELEV ELEVATOR
F; ºF DEGREES FARENHEIT
PLUMBING ABBREVIATIONS
DFU DRAINAGE FIXTURE UNIT
CWFU COLD WATER FIXTURE UNIT
CFH CUBIC FEET/HOUR
FFE FINISH FLOOR ELEVATION
FLR FLOOR
FT FOOT OR FEET
GPM GALLONS PER MINUTE
GAL GALLON
HD HEAD
HTR HEATER
(E) EXISTING
HORIZ HORIZONTAL
HP HORSEPOWER
IN. INCHES
LBS POUNDS
KW KILOWATT
MAX MAXIMUM
MIN MINIMUM
MTD MOUNTED
MANUF. MANUFACTURER
N/A NOT APPLICABLE
NO.; # NUMBER
N.O. NORMALLY OPEN
N.C. NORMALLY CLOSED
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
QTY QUANTITY
PVC POLYVINYL CHLORIDE
PRESS PRESSURE
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSI(G) POUNDS PER SQUARE INCH (GAGE)
PLBG PLUMBING
RECIRC RECIRCULATION
REQ'D REQUIRED
I.E. INVERT ELEVATION
SQ. FT. SQUARE FOOT/FEET
TYP TYPICAL
HWFU HOT WATER FIXTURE UNIT
V VOLTAGE
RPM REVOLUTION PER MINUTE
FDC FIRE DEPARTMENT SIAMESE CONNECTION
FIN FINISH
PIPE UP
PIPE DOWN
PIPE TEE DOWN
CLEAN OUT, FLOORFCO
CLEAN OUT, EXPOSEDCO
CAPPED PIPE
PIPE UNION
THERMOMETER
PRESSURE GAUGEPG
BACK FLOW PREVENTERBFP
BALL VALVE OR SHUTOFF VALVE
PRESSURE AND/OR TEMPERATURE RELIEF VALVEP&TRV
MIXING VALVE
PRV PRESSURE REDUCING VALVE
CHECK VALVECV
CHECK VALVE WITH AUTO DRIP VALVE
OS&Y VALVEOS&Y
OS&Y VALVE WITH TAMPER SWITCHT.S.
FIRE DEPARTMENT SIAMESE CONNECTION(FREE STANDING)
OPEN SITE DRAINOSD
FLOOR DRAINFD
SHOCK ABSORBERSA
WALL HYDRANT- FREEZE PROOF
FIRE DEPARTMENT HOSE VALVEFDHV
BACK WATER VALVEBWV
VENT THRU ROOFVTR
ROOF DRAINRD
WH
AREA DRAIN/GARAGE DRAIN/TERRACE DRAINAD/GD/TD
EXISTING PIPING TO BE REMOVEDDEMO
NON POTABLE WATERNPNP
NP NON POTABLE
FIRE PROTECTION NOTES
1. PROVIDE A COMPLETE FULLY AUTOMATIC SPRINKLER/STANDPIPE SYSTEM, HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA AND ALL LOCAL CODES AND REGULATIONS OF THE AUTHORITY HAVING JURISDICTION. SPRINKLER PIPING LAYOUT AND SPRINKLER LOCATIONS SHOWN ON DRAWING FOR INFORMATIONAL PURPOSES ONLY.
2. ALL FIRE PROTECTION EQUIPMENT, I.E. PIPING, VALVES, FITTINGS, ACCESSORIES, ETC., SHALL BE RATED FOR A MAXIMUM WORKING PRESSURE OF 175 PSI.
3. ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT ALL PORTIONS CAN BE DRAINED BACK THROUGH A DRAIN VALVE.
4. ALL FIRE EQUIPMENT SHALL CONFORM TO LOCAL STANDARDS.
5. SPRINKLER SYSTEM ZONES SHALL BE COORDINATED WITH FIRE ALARM ZONES.
6. ALL CONTROL VALVES AND FLOW ALARM SWITCHES LOCATED ABOVE FINISHED CEILING SHALL BE ACCESSIBLE AND HAVE NOTIFICATION MARKING TAG FOR THE INSPECTOR.
7. ALL ELECTRICAL EQUIPMENT AND TELEPHONE ROOMS SHALL BE SPRINKLERED.
8. ELEVATOR MACHINE ROOM AND SHAFT: SPRINKLER CONTRACTOR SHALL PROVIDE HIGH TEMPERATURE HEADS IN CONJUNCTION WITH HEAT/SMOKE DETECTION SYSTEM. CONTRACTOR SHALL COORDINATE REQUIREMENTS WITH NFPA AND AUTHORITIES HAVING JURISDICTION, SUBJECT TO APPROVAL AND ACCEPTANCE.
9. ALL FIRE EQUIPMENT THREADS SHALL CONFORM TO LOCAL STANDARDS.
10. TAMPER SWITCHES SHALL BE PROVIDED ON ALL FIRE PROTECTION SYSTEM CONTROL VALVES. ANNUNCIATE TAMPER SWITCHES IN ACCORDANCE WITH LOCAL CODES AND REGULATIONS.
11. FLOW ALARM SWITCHES SHALL BE PROVIDED WHERE INDICATED ON PLANS AND/OR REQUIRED BY LOCAL CODES. ANNUNCIATE FLOW SWITCHES IN ACCORDANCE WITH LOCAL CODES AND REGULATIONS.
DEMOLITION NOTES:
1. FIELD VERIFY THE EXACT SIZES AND LOCATIONS OF ALL EXISTING PIPING PRIOR TO DEMOLITION OF ANY EXISTING WORK. THE DEMOLITION WORK SHALL BE COORDINATED WITH THE NEW WORK OF ALL DIVISIONS TO ASSURE PROPER LIMITS OF DEMOLITION.
2. REMOVE ALL EXISTING EQUIPMENT AND ASSOCIATED PIPING, WHETHER SPECIFICALLY INDICATED OR NOT, THAT IS NO LONGER REQUIRED.
3. REMOVE AND CAP EXISTING BRANCH PIPING, NO LONGER REQUIRED TO REMAIN AS PART OF AN ACTIVE SYSTEM, AT THE APPROPRIATE MAIN.
4. ANY PIPING AND DUCTWORK WHICH MUST REMAIN AS PART OF AN ACTIVE SYSTEM AND IS IN CONFLICT WITH THE NEW LAYOUT SHALL BE RELOCATED AT NO ADDITIONAL COST OVER THE CONTRACT AMOUNT.
5. EXISTING FIXTURES, EQUIPMENT AND PIPING REMOVED DURING CONSTRUCTION SHALL REMAIN THE PROPERTY OF THE OWNER AND SHALL BE STORED, REMOVED FROM THE JOB SITE, OR DISPOSED OF AS DIRECTED BY THE OWNER'S REPRESENTATIVE.
6. OPENINGS REMAINING IN WALLS/FLOORS AS A RESULT OF DEMOLITION SHALL BE SEALED WITH AN AIRTIGHT SHEET METAL CAP, UNLESS OTHERWISE NOTED ON THE DRAWINGS.
7. WHERE EXISTING EQUIPMENT IS TO BE RELOCATED, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE REMOVAL AND REINSTALLATION. WHERE DAMAGE OCCURS,THE EQUIPMENT SHALL BE REPLACED OR REPAIRED TO THE SATISFACTION OF THE ARCHITECT, AND OWNERS REPRESENTATIVE AT NO ADDITIONAL COST OVER THE CONTRACT AMOUNT.
8. CONTRACTOR SHALL PROVIDE ADD-ALTERNATIVE PRICE TO REMOVE AND REPLACE EXISTING INTERIOR STORM RISER WITH NEW CAST IRON NO-HUB RISERS. REFER TO DRAWINGS FOR EXTENT OF ADD-ALTERNATIVE DEMOLITION WORK.
X
X-X
DETAIL #
SHEET REFERENCE PLAN DETAIL(IF TYPICAL FLOOR)
X
X-X
SECTION #
SHEET REFERENCE
SECTION CUT
X
X-X
ELEVATION #
SHEET REFERENCE
ELEVATION SYMBOL
X-X
2
134
1 REVISION DELTA
REVISION CLOUD
# DRAWING NOTES
X
X
SHEET REFERENCE
PLAN DETAIL(DIFFERENT FLOOR)
DETAIL #
X
SHEET ORIGIN
DRAWING SYMBOLS
INVERT ELEVATIONI.E.I.E.
FIRE PUMP TEST HEADER
GAS COCK
CONNECT TO EXISTING
EXTENT OF DEMOLITION
P0.01 PLUMBING DATA SHEET
P0.02 PLUMBING SCHEDULES
DP0.01 DEMOLITION TERRACE FLOOR PLAN- PLUMBING
DP0.02 DEMOLITION FIRST FLOOR PLAN- PLUMBING
DP0.03 DEMOLITION SECOND FLOOR PLAN- PLUMBING
DP0.04 DEMOLITION ROOF PLAN- PLUMBING
P1.01 TERRACE FLOOR PLAN- PLUMBING
P1.02 FIRST FLOOR PLAN- PLUMBING
P1.03 SECOND FLOOR PLAN- PLUMBING
P1.04 ROOF PLAN- PLUMBING
P2.01 PLUMBING RISER DIAGRAMS
P3.01 PLUMBING DETAILS
SP1.01 TERRACE FLOOR PLAN- PROPOSED SPRINKLER LAYOUT
SP1.02 FIRST FLOOR PLAN- PROPOSED SPRINKLER LAYOUT
SP1.03 SECOND FLOOR PLAN- PROPOSED SPRINKLER LAYOUT
PLUMBING SHEET INDEX
DRAWING # SHEET TITLE
05/
29/0
9 -
SC
HEM
ATIC
DES
IGN
07/
20/0
9 -
DES
IGN
DEV
ELO
PMEN
T
12/0
4/0
9 -
ISS
UED
FO
R PE
RMIT
GENERAL NOTES
1. ALL SPECIFICATIONS AND DRAWINGS, I.E. ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL, ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION.
2. ANY INFORMATION CONFLICTS WITHIN THE SPECIFICATIONS AND/OR DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK UNTIL ALL CONFLICTS ARE RESOLVED AND THE CLARIFYING INFORMATION IS ISSUED.
3. ALL SANITARY AND STORM SEWER PIPING LESS THAN 3" SHALL BE INSTALLED WITH A 1/4" PER FT. GRADE AND NOT LESS THAN 1/8" PER FT. GRADE FOR PIPING 3" AND LARGER UNLESS NOTED OR INDICATED OTHERWISE. PROVIDE CLEANOUTS ON ALL SEWER PIPING (HORIZONTAL AND VERTICAL) WHERE INDICATED AND/OR REQUIRED BY CODE.
4. COORDINATE ALL PIPING TO BE INSTALLED WITH ALL OTHER TRADES, I.E. MECHANICAL, FIRE PROTECTION, AND ELECTRICAL TO ENSURE THAT ALL PIPING SYSTEMS ARE INSTALLED ABOVE FINISHED CEILING OR IN A CONCEALED SPACE. ALL CEILING HEIGHTS INDICATED ON ARCHITECTURAL AND/OR INTERIOR DESIGN DRAWINGS AS WELL AS MINIMUM CLEARANCES REQUIRED BY LOCAL CODES SHALL BE MAINTAINED THROUGHOUT THE BUILDING.
5. ALL CUTTING, DRILLING, AND PATCHING OF WALLS, FLOORS, AND/OR STRUCTURAL MEMBERS FOR THE INSTALLATION OF PLUMBING SYSTEMS SHALL BE PROVIDED. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED, OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEER'S REVIEW AND PRIOR APPROVAL.
6. PIPING OR EQUIPMENT SHALL NOT BE SUPPORTED FROM STRUCTURAL MEMBER WITHOUT PRIOR REVIEW AND APPROVAL FROM THE STRUCTURAL ENGINEER.
7. ALL BACKFLOW PREVENTER ASSEMBLIES SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. PIPE RELIEF OUTLET, IF APPLICABLE, SHALL DISCHARGE TO NEAREST FLOOR DRAIN. DO NOT INSTALL ABOVE FINISHED CEILING UNLESS NOTED OR INDICATED OTHERWISE.
8. PROVIDE FLOAT TYPE BACKWATER VALVE (SIZED FOR ANTICIPATED FLOW RATE) IN ALL OPEN SITE DRAINS AND FLOOR RECEPTORS RECEIVING A/C CONDENSATE, AND/OR CLEAR WATER WASTE SUCH AS SPRINKLER FLOW TESTING.
9. ALL PIPING SYSTEMS, VALVES, AND EQUIPMENT SHALL BE PROPERLY IDENTIFIED.
10. ALL PLUMBING SHALL CONFORM TO ALL REQUIREMENTS OF THE LOCAL ENERGY CONSERVATION AND PLUMBING CODES OF THE AUTHORITY HAVING JURISDICTION.
11. HOT, COLD, AND RECIRCULATION WATER SUPPLY MAINS AND BRANCHES SHALL BE INSULATED IN ACCORDANCE WITH THE LOCAL ENERGY CODE.
12. ALL PIPING, VALVES, AND ACCESSORIES SERVING EQUIPMENT SHALL BE INSTALLED TO ALLOW SERVICING AND/OR REMOVAL WITHOUT DISCONNECTING ALL PIPING AND ACCESSORIES.
13. ALL VALVES SHALL HAVE THEIR NORMAL (IN OPERATION) POSITION IDENTIFIED, SUCH AS "NORMALLY OPEN" OR "NORMALLY CLOSED."
14. EXPANSION LOOPS AND ANCHORS SHALL BE PROVIDED ON ALL PIPING SYSTEMS WHICH CROSS BUILDING EXPANSION JOINTS AND ALL HORIZONTAL PIPING LENGTHS EXCEEDING 100 FT. OR EACH PORTION THEREOF.
15. ALL NECESSARY EQUIPMENT SHALL BE PROVIDED ON ALL PIPING, UNIONS, VALVES, VACUUM BREAKERS, STRAINERS, ETC. AS REQUIRED TO CONNECT EQUIPMENT AT LOCATION SHOWN, AND TO MAKE FULLY OPERABLE IN ACCORDANCE WITH ALL LOCAL CODES AND REGULATIONS.
16. DRAINS AND CLEANOUTS SHALL BE INSTALLED AS SPECIFIED AND IN LOCATIONS SHOWN ON DRAWINGS. REFER TO THE DRAIN SCHEDULE, IF APPLICABLE.
17. THESE DRAWINGS ARE SCHEMATIC AND ARE INTENDED TO CONVEY A FUNCTIONAL PLUMBING SYSTEM AND TO DEPICT THE GENERAL LOCATION OF THE PLUMBING COMPONENTS.
18. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF PLUMBING WORK WITH THE WORK OF OTHER TRADES. MINOR DEVIATIONS FROM THE PLANS MAY BE MADE TO AVOID MINOR CONFLICTS. WHEN MAJOR CONFLICTS ARE APPARENT, THE CONTRACT OFFICER SHALL BE ADVISED IMMEDIATELY AND AFFECTED WORK SHALL NOT BE CONSIDERED UNTIL THE CONFLICT HAS BEEN RESOLVED.
19. THE CONTRACTOR SHALL VERIFY ALL VOLTAGE AND POWER REQUIREMENTS FOR ALL EQUIPMENT AND COORDINATE WITH THE CONTRACT DRAWINGS PRIOR TO ISSUANCE OF SHOP DRAWINGS AND PURCHASE OF EQUIPMENT.
20. ALL SYSTEMS SHALL BE CLEAN OF FOREIGN MATERIAL AND ROUGH SPOTS PRIOR TO BEING PLACED IN SERVICE AND BEFORE OPERATIONAL TESTS ARE PERFORMED.x
21. INSTALLATION OF ALL EQUIPMENT AND THEIR ACCESSORIES SHALL BE PER MANUFACTURER'S PUBLISHED RECOMMENDATIONS.
22. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL THE PLUMBING SYSTEM SO AS TO ENSURE QUIET OPERATION. NO VIBRATION OF SOUND SHALL BE TRANSMITTED TO THE BUILDING STRUCTURE. THE DECISION OF THE CONTRACT OFFICER AS TO QUIETNESS OF THE SYSTEM AND EQUIPMENT SHALL BE FINAL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CORRECT OR REPLACE ANY NOISY SYSTEMS OR EQUIPMENT AS REQUIRED.
23. PROVIDE ACCESS DOORS AND/OR PANELS NECESSARY TO SERVICE ALL EQUIPMENT AND ACCESSORIES THAT REQUIRE SERVICE AND/OR MAINTENANCE AND ARE LOCATED ABOVE INACCESSIBLE CEILINGS OR WALLS. ACCESS DOOR SIZES SHALL PERMIT FULL ACCESSIBILITY TO EQUIPMENT AND/OR ACCESSORIES, BUT NOT LESS 18" X 18". ACCESS DOORS SHALL MATCH THE WALL OR CEILING RATING AT THE LOCATION WHERE THEY ARE PLACED.
24. ALL PIPING SHALL BE INSTALLED TIGHT TO UNDERSIDE OF STRUCTURAL CONSTRUCTION UNLESS OTHERWISE NOTED.
25. THE CONTRACTOR IS RESPONSIBLE FOR ALL ROUGH-IN, FINAL CONNECTIONS, AND PROPER INSTALLATION OF FIXTURES INCLUDING ASSOCIATED PIPING. MOUNT FAUCETS, SUPPLY ANY TRAPS, VALVES, FITTINGS, VACUUM BREAKERS, PRESSURE GAUGES, OR PRESSURE REGULATORS FOR A COMPLETE INSTALLATION WHICH MEETS THE APPLICABLE CODES.
26. ALL WORK ON THIS PROJECT SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES, REGULATIONS, AND THE AUTHORITY HAVING JURISDICTION.
27. PROVIDE TRAP PRIMER VALVES FOR ALL DRAINS WHICH REQUIRE A SOURCE OF WATER SUPPLY TO MAINTAIN TRAP SEAL. PRIMER VALVES SHALL BE CONNECTED TO THE NEAREST COLD WATER LINE SERVING A FIXTURE.
28. ALL PRODUCTS LOCATED WITHIN PLENUM AREAS, INCLUDING BUT NOT LIMITED TO INSULATION AND ADHESIVE SYSTEMS, SHALL HAVE A COMPOSITE FIRE HAZARD RATING NOT TO EXCEED 25 FLAME SPREAD AND 50 SMOKE DEVELOPED AS DETERMINED BY THE APPLICABLE UL OR ASTM STANDARD.
CONT CONTINUATION
EXISTING PIPING (E) (E)
FLOW SWITCH
HARDWIRE POWER CONVERTER FOR FLUSH VALVEST1
HARDWIRE POWER CONVERTER FOR FAUCETST2
BATTERY BACKUP MODULE FOR FLUSH VALVESB
DUPLEX SUMP PUMP DISCHARGEST/PD ST/PD
REDUCED PRESSURE ZONE ASSEMBLYBACK FLOW PREVENTER
RPZ
WSFU WATER SUPPLY FIXTURE UNIT
PLUMBING FIXTURE SCHEDULEDESIGNATION FIXTURE TYPE C.W. H.W. WASTE MANUFACTURER MODEL NO. FAUCET / FLUSH VALVE ACCESSORIES REMARKS
WC-1 WATER CLOSET- FLUSH VALVE 1" - 4" TOTO CT708 SLOAN- DUAL FLUSH TOLIET SEAT- TOTO SC534 1, 2, 3, 4
WALL MOUNTED BARRIER-FREE ECOS-8111-SF ( 1.6 GPF /1.1 GPF )
WC-2 WATER CLOSET- FLUSH VALVE 1" - 4" TOTO CT708 SLOAN- DUAL FLUSH TOLIET SEAT- TOTO SC534 1, 2, 3, 4
WALL MOUNTED- CHILDREN'S ECOS-8111-SF ( 1.6 GPF /1.1 GPF )
L-1 LAVATORY- 1/2" 1/2" 1 1/2" KOHLER SOHO SLOAN- OPTIMA SLOAN EAF-12 1, 2, 3, 5
WALL MOUNTED BARRIER-FREE K-2084-L EAF-200-P-ISM ( 0.5 GPM ) PROVIDE PLUG-IN TRANSFORMER (T2)
L-2 LAVATORY- 1/2" 1/2" 1 1/2" TOTO VERNICA SLOAN- OPTIMA SLOAN EAF-12 1, 2, 3, 5
UNDERCOUNTER BARRIER-FREE LT156 EAF-200-P-ISM ( 0.5 GPM ) PROVIDE PLUG-IN TRANSFORMER (T2)
SK-1 SINGLE COMPARTMENT SINK- 1/2" 1/2" 1 1/2" ELKAY DAYTON DELTA- TECK VANDAL RESISTANT FLOW CONTROL 1, 2, 3, 5
SELF RIMMING BARRIER-FREE GE12521L 29C2801 AERATOR ( 1.5 GPM )
U-1 URINAL- 3/4" - 2" SLOAN WEUS-1000.1301 SLOAN- OPTIMA TRANSFORMER (T1) SLOAN EL-154 1, 2, 4
ULTRA LOW FLOW -0.13 ES-S 186-0.13 ES-S (0.13 GPF)
U-2 URINAL- 3/4" - 2" SLOAN WEUS-1000.1301 SLOAN- OPTIMA TRANSFORMER (T1) SLOAN EL-154 1, 2, 3, 4
ULTRA LOW FLOW -0.13 ES-S 186-0.13 ES-S (0.13 GPF)
MS-1 MOP SINK 3/4" 3/4" 3" ACORN TERRAZZO-WARE DELTA- TECK - 1, 2
TSH-24-KF24 29C2801 ( 2.2 GPM )
DF-1 DRINKING FOUNTAIN- 1/2" - 1 1/2" ELKAY EDFP217RAC 1, 2, 3
BARRIER-FREE
REMARKS:
1. PROVIDE ALL REQUIRED COMPONENTS FOR COMPLETE FIXTURE ROUGH-IN, I.E., SUPPLIES, STOPS, TRAPS, CARRIERS, GRID DRAINS, TAILPIECES, ETC. NOT ALL REQUIRED COMPONENTS ARE SPECIFIED ABOVE.
2. SEE PLANS & RISERS FOR VENT SIZES AND CONNECTIONS
3. FIXTURES SHALL BE ADA COMPLIANT. PROVIDED WITH ADA COMPLIANT ACCESSORIES. MOUNT ADA COMPLIANT. SEE ARCHITECTURAL PLAN FOR ELEVATIONS.
4. COORDINATE VALVE INSTALLATION WITH ADA GRAB BAR. VALVE SHALL BE LOCATED SO THAT GRAB BAR DOES NOT INTERFERE WITH USE OF VALVE. PROVIDE EXTENSION AS REQUIRED.
5. PROVIDE SKAL + GUARD INSULATING DEVICES ON EXPOSED UNDERCOUNTER PLUMBING.
DRAIN SCHEDULE
DESIGNATION FIXTURE TYPE MANUFACTURER MODEL NO. ACCESSORIES REMARKS
FD-1 FLOOR DRAIN- GENERAL MIFAB F1100 ~ 1
FD-2 FLOOR DRAIN- MECH. RMS. MIFAB F1100-X ~ 1
OSD OPEN SITE DRAIN MIFAB F1100-DD - 1
AD AREA WAY DRAIN MIFAB R1100 - 1
TD TRENCH DRAIN MIFAB T1320-FL ~ 1
PD PROMENADE DRAIN MIFAB R1100-PJ ~ 1
RD-1 ROOF DRAIN- VEGETATED ROOF AREAS MIFAB F1830-P ~ 1
RD-2 ROOF DRAIN- GENERAL MIFAB R1200 ~ 1
OFD-1 OVERFLOW DRAIN- VEGETATED ROOF AREAS MIFAB F1840 ~ 1
OFD-2 OVERFLOW DRAIN- GENERAL MIFAB R1200-W ~ 1
SD SCUPPER DRAIN MIFAB R1320 ~ 1
REMARKS:
1. SEE PLANS & RISERS FOR VENT SIZES AND CONNECTIONS.
2. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS.
3. REFER TO PLUMBING PLANS FOR SIZES.
PUMP SCHEDULE
SYMBOL DESCRIPTION LOCATION BASIS OF DESIGN GPM FT OF HD HP RPM REMARKS
SP-1 ELEVATOR ELEVATOR PIT STANCOR 50 28 1 3600 1, 2
SUMP PUMPS ROOM 009 SE100A
SP-2 DUPLEX MECH 1, 2
SUMP PUMPS ROOM 007
DOMESTIC WATER DUPLEX MINI DOMESTIC FIRE PUMP BELL & GOSSET 40 GPM EA 40 2HP 3500 1, 2, 3
BOOSTER SYSTEM WATER BOOSTER PACKAGE ROOM EA20 EA
FIRE IN-LINE FIRE PUMP FIRE PUMP PEERLESS 500 54 25 1450 1, 2
PUMP ROOM 5PVF7
JOCKEY REGENERATIVE FIRE PUMP MTH 5 60 1/2 3450 1, 2
PUMP JOCKEY PUMP ROOM
REMARKS:
1. REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS.
2. FOR ADDITIONAL INFORMATION REFER TO PLUMBING DETAIL SHEET.
3. SET PRESSURE REDUCING VALVE AT PUMP DISCHARGE TO MAXIMUM 75 PSI.
WATER HEATER SCHEDULE
SYMBOL DESCRIPTION LOCATION MAKE/MODEL SIZE KW TEMPERATURE RISE REMARKS
EWH-1 SINGLE POINT ELECTRIC TANKLESS MOUNT UNDER EEMAX - 4.1 56°F @ 0.5 GPM 1
WATER HEATER LAVATORY MODEL SP4208
EWH-2 THERMOSTATIC ELECTRIC TANKLESS MOUNT UNDER EEMAX - 8.3 57°F @ 1.0 GPM 1
WATER HEATER LAVATORY MODEL EX8208T-ML
EWH-3 ELECTRIC TANK TYPE ABV. MOP AO. SMITH 20 GAL 4.5 18 GPH RECOVERY 1, 2
WATER HEATER SINK MODEL DEL-20 NON-SIMULTANEAUS @ 100ºF RISE
REMARKS:
1. REFER TO DETAIL SHEET FOR MORE INFORMATION.
2. PROVIDE EXPANSION TANK (ET-1) AMTROL MODEL ST-5.
EQUIPMENT SCHEDULESYMBOL DESCRIPTION LOCATION MAKE/MODEL SIZE ELECTRICAL ACCESSORIES REMARKS
BFP-1 BACKFLOW PREVENTER- ROOM 023 WILKINS 3" - - 1
DOUBLE CHECK VALVE ASSEMBLY TERRACE LEVEL 350A
BFP-2 BACKFLOW PREVENTER- ROOM 023 WILKINS 4" - - 2
DOUBLE CHECK DETECTOR ASSEMBLY TERRACE LEVEL 350DA
BFP-3 BACKFLOW PREVENTER- REFER TO PLANS WATTS 1" - - -
REDUCED PRESSURE ZONE ASSEMBLY (AT MECH EQUIP) SERIES 009
BFP-4 BACKFLOW PREVENTER- AT ICEMAKER WATTS 1/2" - - -
IN-LINE DUAL CHECK CONNECTION SERIES 7
WH-1 NON-FREEZE VARIOUS ZURN 3/4" - COVER, VACUUM BREAKER -
WALL HYDRANT REFER TO PLANS Z1300 BRONZE FINISH
GPB-1 NATURAL GAS PRESSURE MECH SPENCER TURBINE - 1 HP - 3
BOOSTER SYSTEM ROOM 007 GL-050-3/4-R
GPR-1 GAS PRESSURE REGULATOR MECH RM 007 MAXITROL 210E 2 x 2 - 1/2" VENT TO EXTERIOR -
REMARKS:
1. MEETS REQUIREMENTS OF ASSE 1015.
2. MEETS REQUIREMENTS OF ASSE 1048.
3. REFER TO DETAIL 8 ON THIS DRAWING FOR MORE INFORMATION. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL REQUIREMENTS.
COMMERCIAL - MINIMUM PIPE INSULATION THICKNESS (PER IPC & IECC) [1]
TEMPERATURESHEATING SERVICE WATER PIPE SIZES
NONCIRCULATING PIPING [2] CIRCULATING MAINS AND RUNOUTS
ALL SIZES - 1ST 8 FEET UP TO 1 1/4" 1 1/2" TO 2" OVER 2"
170-180 ºF 1/2" 1" 1" 1"
140-169 ºF 1/2" 1" 1" 1"
100-139 ºF 1/2" 1" 1" 1"
NOTES:
1. CONDUCTIVITY OF INSULATION k = 0.27 BTU PER INCH/HxSQ.FTxºF - TABLE ADAPTED FROM IECC 2003 SECTION 804.5.
2. NONCIRCULATING PIPING SERVED BY EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS.
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant Library
Washington, DC 20010
3160 16th Street, NW
901 G Street, NW
Washington, DC 20001
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Plumbing Schedules
P0.02
MopSink
Study023
PumpRoom019
Comp./Conf.020
Study018
Stacks017
Adult Non-Fiction015
Elev.009
Elec.008
Women's011
Men's010
Study024
Study022
Study021
Trash006
Young Adult001
Stair003
Conf.012
Storage014
Garden and Entry
Info016
Hallway005
Lobby013
Mech.002
Stair004
Mech.007
eA
eB
eC
eD
eE
eF
e1 e2 e3 e4
e5.2e5.3
e5.7e5.8
e6
e5
eA
eC
eD
eE
eF
e10
e9
e8
e7
eA.5
eC.1
eE.5
eB
1 2 3 4 5 6
A
B
C
D
E
F
G
A.7
C.5
3.9 5.72.3
CO
1 1/2"
CO
CO
11
P3.01
CO
13(E) 4" ST
6" INCOMING FIRE SERVICEREFER TO CIVIL FOR CONT.SET CENTERLINE OF INCOMINGFIRE SERVICE PIPE AT 195.96'
2" INCOMING DOMESTIC WATER SERVICE, REFER TO CIVIL FOR CONT. SET CENTERLINE OF INCOMING PIPE AT 195.90'
F
GENERAL NOTES:A. REFER TO DATA SHEET FOR PLUMBING SYMBOLS AND ABBREVIATIONS.B. REFER TO RISER DIAGRAMS FOR ADDITIONAL SIZES OF UTILITIES AND PIPING.C. FOR PLUMBING FIXTURES AND EQUIPMENT REFER TO SCHEDULES ON DATA SHEET.
DRAWING NOTES:1. PIPING BELOW SLAB.2. PIPING ABOVE CEILING OR TIGHT TO UNDER SIDE OF STRUCTURE.3. PIPING ABOVE FLOOR SLAB IN PIPE CHASE OR WALL.4. FOR CONTINUATION REFER TO CIVIL DRAWINGS.5. RPZ- BACKFLOW PREVENTER BFP-3 FOR MECHANICAL EQUIPMENT. EXTEND FULL SIZE
DISCHARGE TO 4" OPEN SITE DRAIN.6. 4" FOUNDATION DRAINAGE CONNECTION BELOW SLAB. REFER TO STRUCTURAL
DRAWINGS FOR CONTINUATION. INVERT AT 3' BELOW FINISHED FLOOR.7. 1" NON-POTABLE WATER SERVICE FOR MECHANICAL EQUIPMENT.8. PROVIDE ACCESS PANEL IN WALL OR PROVIDE ACCESS BELOW CABINET.9. 1/2" GAS PRESSURE REGULATOR VENT THROUGH EXTERIOR WALL TO OUTSIDE.10. NON-FREEZE WALL HYDRANT.11. OVERFLOW DRAIN THROUGH EXTERIOR WALL AND SPILL TO GRADE.12. GAS METER BY LOCAL GAS COMPANY.13. CONTRACTOR SHALL PROVIDE ADD-ALTERNATIVE PRICE TO REPLACE EXISTING STORM
RISER WITH NEW CAST IRON NO-HUB RISER FROM THE ROOM DOWN TO THE POINT OF TERMINATION. 14. 1" RPZ DISCHARGE AND 2" SUMP PUMP DISCHARGE TO 4" OPEN SITE DRAIN. PROVIDE
TAILPIECE AND TERMINATE PIPE AT 45° SAW CUT ANGLE.15. SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.16. EXTEND TO AUTOMATIC HYDRAULICALLY CALCULATED FULLY SPRINKLERED SYSTEM.
#
U-2
4
1
P1.01
1
4
(E) 4" SANITARY
(E) 4"
G
G
2
P1.01
4" FD-2
2" (1,000 CFH)
EX 4" ST
(E) 4" ST
EX 4" ST
(E) WH TO BE REMOVED &REPLACEDWITH NEW H-1
4
ST/P
D
SP-2
6" F- UP TO FIRE DEPARTMENT SIAMESE CONNECTION
I.E. 185.6'
FIRE PUMP ROOM
8" F- UP TO FIRE PUMP TEST HEADER
CO
TO BE FIELD VERIFIEDBY CIVIL ENGINEER
13
13
13
9
U-1
WC-2WC-2L-2
L-2
L-2
L-2WC-1
F
SP-1
2
1
4"
4"
F
DF-1
2
WC-1
F
M
TP
1/2"
12
MECH BOILERS
1 6
PD
GPB-1
MAINTAIN MINIMUM 18" CLEARANCE
GPR-1
4" OSDMS-1
1 1/2" G(500 CFH) (TYP)
14
EWH-3
11
P3.01
1"
7
PD
5 BFP-3
7
3/4"4"3"
1
1
SP
F1
4" F- UP
16 15
BELOW GRADE
F
2
2
2
2"
1" CW- UP
4" SAN- UP
1
3" V- UP
23"
6" ST- UP & DN(4,315 SQ. FT.)
ST
4
4
CO
6" ST
ST
1
2
2"
2"
ST/PD
2" CW
1 1/4" CW- UP1 1/4"
3/4"
3/4"
3/4"
1"2"4"
2"
2"1"1/2"
4"
4" SAN- UP
1
3/4"CW- UP
2"4"
10
W21" NP WATER- UPTO COOLING TOWER
W2
(E)CO
3" V- UP
2"
4"
F
W1
1
e10
e9
e8
e7
Study023
PumpRoom019
Comp./Conf.020
Study024
0224" FIRE TO FREE STANDINGFIRE DEPT SIAMESE CONNECTION,ROUTE PIPING THROUGHCHASE IN STUDY ROOM
TP
F F
F
F
F
F
6" INCOMING FIRE SERVICE
2" INCOMING DOMESTICWATER SERVICE
PLUMBING CHASEWITH FULL SIZEACCESS DOOR
6" BFP-2
FIRE PUMP & JOCK PUMP CONTROLLERS
IN-LINE ELECTRIC FIRE PUMP FP-1 JOCKEY PUMP JP-1 OS&Y WITH TAMPER SWITCH (TYP)
DOMESTIC WATERBOOSTER PACKAGE BP-1
RAISED THRESHOLD TO PREVENTPOSSIBLE WATER DAMAGE
4"
4"
4"
3" FD-2
4"OSD
4"
4"
2"
2" BFP-1
3" FD-2
TP
F
TP
3" FD-2
F
6" FIRE TO FIRE PUMPTEST HEADER, ROUTEPIPING THROUGH CHASEIN STUDY ROOM
2"4"
3" V- UP
e5.2e5.3
e5
eA.5
TERRACE FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
3
P1.01
PART PLAN- PUMP ROOMSCALE: 1/4" = 1'-0"
1
P1.01
PART PLAN- TOILET ROOMSSCALE: 1/4" = 1'-0"
2
P1.01
3
D
C.5
Elev.
Women's011
Men's010
CO
EWH-2
L-2
L-2
L-2
WC-2
U-1
U-2
EWH-2
2"
4"
4"
CO
WC-1
WC-1
WC-2L-2
2"
2"
4"
TP
TP
1
2
2" CW- DN
4"
2"
3" FD-1
3" FD-1
3" FD-1
4"
2"
TP
3/4"
1 1/4"
2"
3"3"
3"3"3"3"4"3/4"
3"
3
3
2
2
1
3"
3
3
1
1 1/4"
T1
T2
POWER CONVERTERFOR (2) FAUCETS
2"
8 POWER CONVERTERFOR (2) URINAL FV'S
T2
8 POWER CONVERTERFOR (2) FAUCETS 8
4" 4"1
2
1 1/2"
3"1 1/4"
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WEREPREPARED OR APPROVED BY ME, AND THAT I AM ADULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant LibraryWashington, DC 200103160 16th Street, NW
901 G Street, NWWashington, DC 20001
N0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Terrace Floor Plan- Plumbing
P1.018'0
GRAPHIC SCALE 1/4" = 1'-0"
1' 2' 4' 6'
1-13-10 BID SET
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WEREPREPARED OR APPROVED BY ME, AND THAT I AM ADULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant LibraryWashington, DC 200103160 16th Street, NW
901 G Street, NWWashington, DC 20001
N0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
First Floor Plan- Plumbing
P1.02
1-13-10 BID SET
Open above
Open above
Stacks115
Elev.109
Storage107
Vestibule108
UP
DOWN
UP DOWN
DOWN
DOWN
PORCH
UP DOWN
ExitVestibule
101
Stair103
Display116
Stair111
Circulation114
Stacks102
Workroom113
EntryVestibule
117
EntryHall110
Pantry105
ITCloset
112
Stair104
MeetingRoom
106
eA
eB
eC
eD
eE
eF
e1 e2 e3 e4
eA
eB
eC
eD
eE
eF
e10
e9
e8
e7
eA.5
eC.1
eE.5
e5.2e5.3
e5.7e5.8
e6
e5
2 3 4 5 6
A
B
C
D
E
F
G
1
A.7
C.5
3.9 5.72.3
CO
GENERAL NOTES:A. REFER TO DATA SHEET FOR PLUMBING SYMBOLS AND ABBREVIATIONS.B. REFER TO RISER DIAGRAMS FOR ADDITIONAL SIZES OF UTILITIES AND PIPING.C. FOR PLUMBING FIXTURES AND EQUIPMENT REFER TO SCHEDULES ON DATA SHEET.
DRAWING NOTES:1. PIPING BELOW SLAB.2. PIPING ABOVE CEILING OR TIGHT TO UNDERSIDE OF STRUCTURE.3. PIPING ABOVE FLOOR SLAB IN PIPE CHASE OR WALL.4. SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.5. EXTEND TO AUTOMATIC HYDRAULICALLY CALCULATED FULLY SPRINKLERED SYSTEM.6. INSTANTANEOUS WATER HEATER LOCATED ABOVE FLOOR IN MILLWORK OR CABINET.
RUN 1/2" COLD WATER TO WATER HEATER IN CABINET.
#
F1
4" F- UP & DN
FREE STANDING FIRE DEPARTMENT SIAMESE CONNECTION 6" X 2 1/2" X 2 1/2" W/ CAPS & CHAINS (CHROME)
FREE STANDING FIRE PUMP TEST HEADER 8" X 2 1/2" X 2 1/2" W/ F.D. VALVES, CAPS & CHAINS (CHROME)
3" V- UP
4" OFD- DN(1,140 SQ.FT.)
3" OFD- DN(925 SQ.FT.)
2
4
5
W1
1" CW-UP & DN
4" SAN- UP
4"2
4" SAN- DN
3" OVERFLOW PIPING THROUGHEXTERIOR WALL & SPILL TOSPLASH BLOCK 18" ABOVE GRADE
4" OVERFLOW PIPING THROUGHEXTERIOR WALL & SPILL TOSPLASH BLOCK 18" ABOVE GRADE
6" ST- UP & DN(4,315 SQ. FT.)
1 1/4" CW-UP & DN
4" SAN- UP
CO4"
4" SAN- DN SK-1
2
31
1 1/2"
4"1 1/2"
3/4" CWFROM BELOW
1/2"
EWH-26
W2
1" NP WATER- UPTO COOLING TOWER
W3
3" V- UP & DN
SP
2 F
FIRST FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
1
P1.02
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WEREPREPARED OR APPROVED BY ME, AND THAT I AM ADULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant LibraryWashington, DC 200103160 16th Street, NW
901 G Street, NWWashington, DC 20001
N0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Second Floor Plan- Plumbing
P1.038'0
GRAPHIC SCALE 1/4" = 1'-0"
1' 2' 4' 6'
1-13-10 BID SET
Open below
Open below
EDGE OF CANOPYBELOW
Ship's Ladder
to Attic
Elev.209
Friends of the Library
211
Info216
Staff Lounge210
Workroom214
Bridge212
Alcove221
Storage220
UP
UP
RAMPUP
DOWN
UP
DOWN
DOWN
Reading218
YoungChildren
219
ElevatorControl Closet
206
StaffBathroom
208
Elec.213
RoofAccess
205
Children'sStacks
201
Stair202
BranchManager
204
Strollers203
Workroom207
Children's Program
217
Alcove220
Bathroom215
eA
eB
eC
eD
eE
eF
e1 e2 e3 e4
eA
eB
eC
eD
eE
eF
e10
e9
e8
e7
eA.5
eC.1
eE.5
e5.2e5.3
e5.7e5.8
e6
e5
UP
2 3 4 5 6
A
B
C
D
E
F
G
1
A.7
C.5
3.9 5.72.3
4" FD-2
CO
GENERAL NOTES:A. REFER TO DATA SHEET FOR PLUMBING SYMBOLS AND ABBREVIATIONS.B. REFER TO RISER DIAGRAMS FOR ADDITIONAL SIZES OF UTILITIES AND PIPING.C. FOR PLUMBING FIXTURES AND EQUIPMENT REFER TO SCHEDULES ON DATA SHEET.
DRAWING NOTES:1. PIPING BELOW SLAB.2. PIPING ABOVE CEILING.3. PIPING ABOVE FLOOR SLAB IN PIPE CHASE OR WALL.4. VICTAULIC FIRE-PAC DRY VALVE SPRINKLER CABINET. SIZE AIR COMPRESSOR
BASED ON MANUFACTURER'S RECOMMENDATIONS.5. SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.6. EXTEND TO AUTOMATIC HYDRAULICALLY CALCULATED FULLY SPRINKLERED SYSTEM.7. PROVIDE ICE MAKER OUTLET BOX BY OATEY OR APPROVED EQUAL.8. PIPING, VALVE OR EQUIPMENT LOCATED ABOVE FLOOR IN MILLWORK OR CABINET.
#
F F
4"
4" SP (DRY)- UPTO ATTIC
1
P1.03
SK-1L-1WC-1
3" UP TO 3" OFD-1(225 SQ. FT.)
3" ST UP TO 3" RD-1(400 SQ. FT.)
3" UP TO 3" OFD-1(400 SQ. FT.)
3" ST UP TO 3" RD-1(225 SQ. FT.)
3" ST UP TO 3" RD-1(570 SQ. FT.)
3" UP TO 3" OFD-1(570 SQ. FT.)
3" ST UP TO 3" RD-1(570 SQ. FT.)
3" UP TO 3" OFD-1(570 SQ. FT.)
3" ST UP TO 3" RD-1(300 SQ. FT.)
3" UP TO 3" OFD-1(300 SQ. FT.)
OFD CO
3"
3"
4"
4" OFD- DN(1,140 SQ.FT.)
OFD
OFD
OFD
OFD
CO
3" OFD- DN(925 SQ.FT.)
2
2
2
4
SP DRY
SP
F1
2 65
W1
1" CW-UP & DN
1"
4" SAN- DN
3" V- UPTO 3" VTR
ST
3"
ST
CO
2
ST
4" (2,245 SQ. FT.)
3"
ST
6" (2,815 SQ. FT.)
6" ST- DN(4,315 SQ. FT.)
ST
1 1/4"CW- DN
4" SAN- DN
W2
1" NP WATER- UPTO COOLING TOWER
W3
1"
(NP)
(NP)
3" V- UPTO 3" VTR
3" V- DN
4" ST- UP TO4" GUTTER(750 SQ. FT.)
4" ST- UP TO4" GUTTER(750 SQ. FT.)
4" ST- UP TO4" GUTTER(750 SQ. FT.)
ST 4"
4"
4"
ST 4" (750 SQ.FT.)
ST
4"(750 SQ.FT.) 2
4" F- UP& DN
1"
TP
SECOND FLOOR PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
3
P1.03RESTROOM & KITCHEN PART PLAN- PLUMBINGSCALE: 1/4" = 1'-0"
1
P1.03
Staff Lounge210
WC-2
L-1
SK-1
4" SAN- DN3 3
1 1/4"
EWH-1
T2
BFP-4
7
8
1/2" CW- TOICEMAKER
1
2
3" V- UP TO 3"VTR & 3" V- DN
4" 2"1"
EWH-23/4"
1/2" H & CWTO SK-1
8REF
CO
43.9
G
SECOND FLOOR PART PLAN- PLUMBINGSCALE: 1/4" = 1'-0"
2
P1.03
Storage220
WC-2
L-1
4" SAN- DN
3
3" V- UPTO 3" VTR
1 1/2"
4"
1"
3"
EWH-1
T2
POWER CONVERTERFOR FAUCETS
e9eE
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant Library
Washington, DC 20010
3160 16th Street, NW
901 G Street, NW
Washington, DC 20001
N
0
GRAPHIC SCALE 1/8" = 1'-0"
1' 4' 8' 12' 16'
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Roof Plan
- Plumbing
P1.04
Skylight
eA
eB
eC
eD
eE
eF
eA
eB
eC
eD
eE
eF
e10
e9
e8
e7
eC.1
eE.5
A
B
C
1 2 3 4 5
D
E
F
G
6
A.7
C.5
3.9 5.72.3
GENERAL NOTES:
A. REFER TO DATA SHEET FOR PLUMBING SYMBOLS AND ABBREVIATIONS.B. REFER TO RISER DIAGRAMS FOR ADDITIONAL SIZES OF UTILITIES AND PIPING.C. FOR PLUMBING FIXTURES AND EQUIPMENT REFER TO SCHEDULES ON DATA SHEET.
DRAWING NOTES:
1. ENTIRE ATTIC SHALL BE FULLY SPRINKLERED BY A DRY PIPE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA AND LOCAL CODES.2. 4" STORM WATER PIPING CONNECTED AT BOTTOM OF ARCHITECTURAL ROOF GUTTER,
REFER TO DETAIL 3 ON ARCHITECTURAL DRAWING A8.31 FOR DETAIL.3. 1" NON POTABLE WATER TO MECHANICAL COOLING TOWER. REFER TO MECHANICAL
DRAWINGS FOR CONTINUATION. COMPLETELY HEAT TRACE NON POTABLE WATER LINE ON ROOF UP TO 2' BELOW ROOF STRUCTURE, REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL REQUIREMENTS.
EXISTING DOWNSPOUTSEE NOTE 13 DWG P1.01
EXISTING DOWNSPOUTSEE NOTE 13 DWG P1.01
EXISTING DOWNSPOUTSEE NOTE 13 DWG P1.01
1
3" RD-1(225 SQ. FT.)
3" OFD-1(225 SQ. FT.)
3" OFD-1(300 SQ. FT.)
3" RD-1(570 SQ. FT.)
3" OFD-1(570 SQ. FT.)
ARCHITECTURAL ROOF GUTTERREFER TO ARCHITECTURAL DWGSFOR MORE DETAIL
EXISTING DOWNSPOUTSEE NOTE 13 DWG P1.01
3" RD-1(400 SQ. FT.)
3" OFD-1(400 SQ. FT.)
3" RD-1(570 SQ. FT.)
3" OFD-1(570 SQ. FT.)
EXISTING DOWNSPOUTSEE NOTE 13 DWG P1.01
3" RD-1(300 SQ. FT.)
2
2
2
#
3" VTR
3" VTR
3
1" (NP)WATER- DN
EXISTING DOWNSPOUTSEE NOTE 13 DWG P1.01
3" VTR
ROOF PLAN- PLUMBINGSCALE: 1/8" = 1'-0"
1
P1.04
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A
DULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant Library
Washington, DC 20010
3160 16th Street, NW
901 G Street, NW
Washington, DC 20001
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Plumbing
Riser Diagrams
P2.01
CO
F
SANITARY RISER DIAGRAMNO SCALE
5
P2.01
TERRACE FLOOR
FIRST FLOOR
SECOND FLOOR
ROOF
TERRACE FLOOR
FIRST FLOOR
SECOND FLOOR
ROOF
TERRACE FLOOR
FIRST FLOOR
SECOND FLOOR
ROOF
TERRACE FLOOR
FIRST FLOOR
SECOND FLOOR
ROOF
TERRACE FLOOR
FIRST FLOOR
SECOND FLOOR
ROOF
TERRACE FLOOR
FIRST FLOOR
SECOND FLOOR
ROOF
(E) CO
(E)
(E) 4"(68.5 DFU)
EXISTING 4" SANITARYSEWER LATERAL. REFER TO CIVIL DWG FOR CONT.
I.E. 185.6'
FIELD VERIFY PRIOR TO STARTOF ANY INSIDE SANITARYPIPING. REPORT TO ARCH/ENGINEER IF INV. EL. INSTALLEDLOWER THAN ANTICIPATED.
DS
DS
EXISTING DOWNSPOUT TO REMAIN REFER NOTE #13 DWG P1.01.
(E) 4"
(E) 4"
NATURAL GAS CALCULATIONS BASED ON INTERNATIONAL FUEL GAS CODE:SCHEDULE 40 METALLIC PIPINGINLET PRESSURE = LESS THAN 2.0 PSI PRESSURE DROP = 0.3" W.C.EQUIVALENT LENGTH = 40' SPECIFIC GRAVITY= 0.60TOTAL LOAD = 1,000 CFH
G
GAS METER, MAIN SHUT-OFFAND PRESSURE REGULATORBY LOCAL GAS COMPANY
M
INCOMING LOW PRESSURE GASSERVICE BY LOCAL GAS COMPANY REFERTO CIVIL DRAWINGS FOR CONTINUATION
G
2" (1,000 CFH)
1 1/2" (500 CFH)
TO B-1MECH BOILER(500 CFH)
G
TO B-1MECH BOILER(500 CFH)
G
G G
G
G
P3.01
8
PROVIDE GAS BOOSTER SYSTEMTO BOOST TO 14" W.C.MAINTAIN 18" CLEARANCE
FLANGED EXPANSION JOINT ON INLET ANDDISCHARGE PIPING IN ACCORDANCE WITHSPECIFICATION. MANUAL BY-PASS PACKAGEDAS PART OF GAS BOOSTER SYSTEM
1/2" GAS PRESSURE REDUCINGVALVE VENT TO EXTERIOR
GPR-1
SP-2, DUPLEX SUMP PUMP PACKAGE
ST/
PD
6" TO FOUNDATION DRAIN (BY OTHERS)
2"
BACK WATER VALVE
DOMESTIC WATER RISER DIAGRAMNO SCALE
4
P2.01
AIR CHAMBER
W1
2 1/2"
3"
DF-1SA
WC-2 U-1 WC-1
U-2
1"
SK-1
1/2"
3/4"WH-1
3/4"
GAS COCK1 1/2" (500 CFH)
1/2"
3" INCOMING DOMESTICWATER SERVICE, REFERTO CIVIL DRAWINGS FORCONTINUATION
FIRE PROTECTION RISER DIAGRAMNO SCALE
3
P2.01
F
F
IN-LINE FIRE PUMP FP-1
JOCKEY PUMP JP-1
CONCENTRIC REDUCER
ECCENTRIC REDUCER
FREE STANDING FIRE PUMP TEST HEADER
RISER CONTROL VALVEAT THE BASE OF STAIR 003
SP
SP
SP
EXTEND TO HYDRAULIC CALCULATED FULLY SPRINKLERED WET PIPE SYSTEM
FREE STANDING FIRE DEPARTMENT SIAMESE CONNECTION
3/4" AUTO BALL DRIPGUARDIAN MODEL 6432
FF
F
SPF1
EXTEND TO HYDRAULIC DESIGNED SPRINKLER DRY- PIPE SYSTEM IN ATTIC
A
DRY- PIPE VALVE AND COMPLETE SYSTEM IN FACTORY MADE CABINETBY VICTAULIC OR APPROVED EQUAL
4" INCOMING FIRESERVICE, REFER TOCIVIL DRAWINGS FORCONTINUATION
4"4"
4" 4"
3" BFP-1
4" BFP-2
4"
3"
P3.01
2
F
3" FD-2
F
3" FD-2
F
(DRY)
EXTEND TO HYDRAULICCALCULATED FULLY SPRINKLERED WET PIPE SYSTEM
EXTEND TO HYDRAULICCALCULATED FULLY SPRINKLERED WET PIPE SYSTEM
NATURAL GAS BOOSTERSYSTEM (GBP-1), REFER TODETAIL FOR MORE INFORMATION
STORM WATER RISER DIAGRAMNO SCALE
2
P2.01
GAS RISER DIAGRAMNO SCALE
1
P2.01
3"
P3.01
2
3" FD-2
3"
3"
DOMESTIC WATERBOOSTER PACKAGE
3/4"
EWH-2
EWH-3
ET-1
3/4" (3 WSFU)
MS-1
VACUUM RELIEF VALVECOMPLY WITH ANZI Z21.22
P3.01
11
BFP-3
1" 1"
NP
1" NON POTABLE WATER TO MECH BOILERS, REFER TO MECH DWGS FOR CONT.
1" NON POTABLE WATER TO MECH CHILLER, REFER TO MECH DWGS FOR CONT.
NP
FULL SIZE DISCHARGE TO4" OPEN SITE DRAIN
2" ST/ PUMP DISCHARGETO 4" OPEN SITE DRAIN
2" (64 WSFU)3/4" (2 WSFU)
1/2" (0.25 WSFU)2" (64 WSFU)
L-2
1/2"
EWH-2
1 1/4" (20 WSFU)
3/4"(4 WSFU)
1/2"
1 1/4" (16 WSFU)
L-2
1/2"
EWH-23/4"(4 WSFU)
1/2"
3/4" (4 WSFU)
WC-2WC-1
1 1/4"
2" (54 WSFU)2" (50 WSFU)
1 1/2" 2"
2" (50 WSFU)
AIR CHAMBER
W2
L-1 EWH-1
1/2"1" 1"
1" (12 WSFU)
1" (12 WSFU)
1 1/4" (16 WSFU)
2" (69.25 WSFU)
TO ICEMAKER
BFP-4
L-1
1/2"
EWH-2L-1
1/2"
EWH-1WC-2
1/2"
3/4" (2 WSFU) 1" (12 WSFU)
1"
NP
1" NON POTABLE WATER TO MECH COOLING TOWER,REFER TO MECH DWGS.PROVIDE HEAT TRACING ONNON POTABLE WATER LINEON ROOF AND 2' FEET BELOW ROOF
1"
1"
1"
W3
1" NON POTABLE WATER TO MECH COOLING TOWER
(E) DOWNSPOUT CONNECTION TOREMAIN, REFER TO CIVIL DRAWINGSFOR CONTINUATION
2" (81.25 WSFU)
WC-2
L-2 L-2
1 1/4" (16 WSFU) 1" (12 WSFU)
(E) CO
4" 4"
4"
CO
4"
4" (7 DFU)
4" FD-2
TP
4" (2 DFU)
WC-22"
3"
3" VTR
L-11 1/2"
1 1/2"4"
3"
2"
CO
4"
DF-1
2"
1 1/2" (0.5 DFU)
1 1/2"
4" (9 DFU)
CO
4"
4"
CO4" (7 DFU)
SK-1
1 1/2"
1 1/2"
2" (2 DFU)
4"
4"
WC-2
3"L-1
1 1/2"
1 1/2"
4"
3" VTR
4"
1 1/2"
SK-11 1/2"
2"
4"
3"
3"
CO
WC-2
4"
WC-2WC-1
3"3"
WC-1
3"U-1U-2
4"2"2"4" (16 DFU)
2" (4 DFU)
4" (20 DFU)
1 1/2"
3" FD-1
TP
3" (2 DFU)
2"L-1
1 1/2"2"
2" (2 DFU)
4" (14 DFU)
4" (34 DFU)
L-1
1 1/2"
3"
1 1/2"
3"
1 1/2"
PD
2" ELEVATOR PD FROM SP-1TO 4" OPEN SITE DRAIN
CO4" OSD
PD
TP
MS-24" FD-2
2"
3"
4" (6 DFU) 4" (2 DFU)
4" (2 DFU)
4" (10 DFU)
3"
TP
3" FD-1
2"
2"
2" VENT TO3" VENT RISER
2" VENTFROM SP-2
3"2"
4" OSD
TP
3" FD-2
3" VTR
3"
TP
3" FD-2
3"
TP
3" FD-2
2"3"
L-1
1 1/2"2" (2 DFU)
L-1
1 1/2"
2"
3" (2 DFU)4" (34 DFU)4" (9 DFU)
CO
3"
TP
3" FD-1
3" (6 DFU)
4" (40 DFU)4" (49 DFU)4" (49.5 DFU) 4" (9 DFU)
4" (56.5 DFU)
4" (12 DFU)
T 202.466.6116F 202.466.6235
T 301.881.2545F 301.881.0814
AMT12750 Twinbrook ParkwayRockville, MD 20852
T 410.381.7100F 410.381.7110
7061 Deepage DriveColumbia, MD 21045
T 202.452.1103F 202.452.1133
ReStl Designers, Inc.1001 Connecticut Ave, NW, Suite 320Washington, DC 20036
Civil Engineer
MEP Engineer
Structural Engineer
08002.10Project No.
I CERTIFY THAT THESE DOCUMENTS WEREPREPARED OR APPROVED BY ME, AND THAT I AM ADULY LICENSED ARCHITECT UNDER THE LAWS OF
DISTRICT OF COLUMBIA
© core group, pc 2008
1010 wisconsin avenue, nwsuite 405washington, dc 20007
11/11/08Printed:
REV DT ISSUED
Architect
T 202.588.5454F 202.588.5449
2410 17th Street, NW, Suite 201Washington, DC 20009
Landscape Architect
T 212.696.0414
3 East 28th Street, 6th FloorNew York, NY 10016
Mt. Pleasant LibraryWashington, DC 200103160 16th Street, NW
901 G Street, NWWashington, DC 20001
5-29-09 SCHEMATIC DESIGN
ASE JOB# 0811_179
7-17-09 DESIGN DEVELOPMENT
12-4-09 ISSUED FOR PERMIT
Plumbing Details
P3.01
1-13-10 BID SET
DETECTOR CHECK METER DETAILNO SCALE
12
P3.01
FOUNDATION DRAINAGE DETAILNO SCALE
1
P3.01
4" PVC FOUNTAIN DRAIN WITHPERFORATIONS AT BOTTOM OFPIPE ONLY. PIPING SHALL BEINSTALLED LEVEL.
I.E. 185.6'
4" PVC WEEP GROUT WITHWATER TIGHT SEALANT 4'-0" O.C.COORDINATE WITH STRUCTURALBEAM.
4" PVC (NO PERFORATIONS)
REFER TO STRUCTURAL DETAIL
NOTE:ALL FOUNDATION DRAINAGE PIPING SHOWN ON PLUMBINGDRAWINGS IS FOR INFORMATIONAL PURPOSE ONLY.
FREESTANDING FIRE DEPARTMENT CONNECTION DETAILNO SCALE
2
P3.01
4" FIRE PIPING TOFREESTANDING FDC
GRADE ORPAVING
4" FIRE PIPINGFROM BUILDING
4" x 2-1/2" x 2-1/2"FREESTANDINGFIRE DEPARTMENTCONNECTION
4" FIRE PIPING TOFREESTANDING FDC
1
P1.01
3/4" AUTO BALL DRIPFOR SYSTEM DRAINGUARDIAN MODEL6432
4" FIRE PIPING TOFREESTANDING FDCMINIMUM 4' COVER
@ LAVATORY @ FLUSH VALVE
WATER CLOSETFLUSH VALVE
ESCUTCHEON
DISCHARGE TOFIXTURE
ESCUTCHEON
EXTEND TO TRAPWITH 1/4" TUBING
ESCUTCHEON
COLD WATER SERVICESTOP UNDER LAVATORY COLD WATER
TO LAVATORY
6" X 1/2" CHROMENIPPLE AND ELL
1/4" FERRULE X 1/2"M.I.P. ADAPTOR
1/4" FERRULE X 1/2"M.I.P. ADAPTOR
EXTEND & CONNECTTO DRAIN PRIMERTAPPING WITH 1/4"SOFT COPPER TUBING
ESCUTCHEON
TRAP PRIMER PIPING DETAIL 1NO SCALE
5
P3.01
PUMP
ANTI-VIBRATION PAD (TYP)
SUCTION
FLOW SWITCH (TYP)
CONTRACTOR TO CONNECTAT THIS POINT
SHUT-OFF VALVE (TYP)COMBINATION PRESSURE REGULATING VALVE (PRV)& CHECK VALVE BY PUMP MANUFACTURER (TYP)
PRESSURE GAUGE (TYP)
4" HOUSE KEEPING PAD
SKID BASE
CONTROL PANEL
CHECK VALVE (TYP)
HYDRO-PNEUMATIC TANKWITH PRESSURE GAUGE
PUMP
NOTE: ALL SENDING AND CONTROL TUBING SHALL BE COPPER OR STAINLESS STEEL ONLY.
DOMESTIC WATER BOOSTER PUMP PACKAGE DETAILNO SCALE
7
P3.01
FIRE SERVICE FROM DOUBLE CHECK DETECTOR ASSEMBLY
CONCRETE PAD(TYPICAL)
JOCKEY PUMP
CHECK VALVE(TYPICAL)
GATE VALVE (TYPICAL)
STRAINER
ECCENTRIC REDUCER
DISCHARGE GAUGE
CASE RELIEF VALVE
SUCTION GAUGE
JOCKEY PUMP CONTROLLER
CONCENTRIC REDUCER
CHECK VALVE (TYPICAL)
FLOOR
FULL SIZE BY-PASS
O S&Y VALVE W/ TAMPER SWITCH (TYP)
TO BUILDING SPRINKLER SYSTEM. SEE RISER AND PLANS FOR SIAMESE CONNECTION
TO FIRE PUMP TEST HEADERS, PROVIDE AUTO BALL DRIP
GAUGE
UNION (TYPICAL)
12" HOUSEKEEPING PAD
FIRE PUMPCONTROLLER
ELECTRIC FIRE PUMP DETAILNO SCALE
4
P3.01
UNION
DRAIN VALVE
INSPECTOR'S TEST VALVE
PRESSURE GAUGE (0 TO 250 PSI)
O.S.&Y VALVE W/TAMPER SWITCH
CHECK VALVEFLOW SWITCH TO FLOOR
SPRINKLER SYSTEM
DRAIN RISER SIGHT GLASS
SPRINKLER FLOOR CONTROL VALVE ASSEMBLY DETAILNO SCALE
3
P3.01
TRAP PRIMER DETAIL 2NO SCALE
6
P3.01
AVOID DIRECT INSTALLATION TO PREVENT FOREIGN MATERIAL FROM ENTERING THE PRIMER VALVE
TRAP PRIMER VALVE MINIMUM 12" ABOVE FINISHED FLOOR.
COMPRESSION FITTING
1/2" SUPPLY TO FLOOR DRAINS
COLD WATER SUPPLY LINE
TRAP PRIMER
10
8
NOTES:
1. HERMETIC NATURAL GAS BOOSTER PUMP.2. PRESSURE GAUGE (DISCHARGE).3. PLUG VALVE.4. NATURAL GAS DISCHARGE.5. FLEXIBLE GAS CONNECTION.6. BRASS BALL VALVE.7. PRESSURE GAUGE (INLET).8. 6mm BALL VALVE.9. NEMA-12 CONTROL PANEL.10. NEMA-4 JUNCTION BOX.
DISCHARGEINLET
9
72
4
3
1
6
5
NATURAL GAS BOOSTER SYSTEM DETAILNO SCALE
8
P3.01
OIL MINDERCONTROL
36
ELECTRICALROOM
OIL-MINDER POWERCABLE, PROBE CABLE,AND HIGH LIQUIDALARM CABLE,LENGTHS ASREQUIRED, IN CONDUIT
FLOOR
ELECTRICALOUTLET NIPC
POWER SUPPLY
9
4
5
4" SCHED 40PVC CONDUITWITH LONG RADIUS BENDS
OPEN GRATING WITH CUT-OUT FOR DISCHARGE &ELECTRICAL CONDUIT
PUMP ON-OFFFLOATOIL-MINDER
PROBE
ANGLE IRONSUPPORT
7
2
1
1) STANCOR MODEL SE-100 SUBMERSIBLE EFFLUENT PUMP 1HP. 115 VOLT, 3600 RPM, 2" DISCHARGE CONNECTION2) STANCOR CHECK VALVE3) STANCOR OIL MINDER 115V, 1 PHASE CONTROL SYSTEM WITH OPTIONAL BUILT-IN AUDIBLE AND VISUAL ALARM WHEN
PUMP DOES NOT RUN DUE TO OIL IN PIT OR HIGH LIQUID CONDITION. PROVIDE SIILENCING BUTTON FOR AUDIBLE ALARM BUILT INTO PANEL. PANEL SHALL HAVE ADDITIONAL CONTACT FOR A REMOTE ALARM LOCATION.4) WATERTIGHT SLEEVE5) PROVIDE BYPASS SHUTOFF VALVE AND HOSE BIB, TO TEMPORARILY PUMP LIQUIDS. HOSE BIB TO BE NORMALLY CLOSED,
AND VALVE TO BE NORMALLY OPEN.6) OIL MINDER POWER CABLE, PROBE, AND HIGH LIQUID ALARM CABLE7) HIGH LIQUID ALARM FLOAT WITH CLAMP DEVICE TO MOUNT TO PUMP DISCHARGE PIPING8) PROVIDE A MINIMUM OF 5 FT. EXTRA OF EACH CABLE (SLACK) ROLLED AND CLAMPED TO THE DISCHARGE PIPE TO
ALLOW FOR THE REMOVAL OF THE PUMP FROM THE PIT.9) SEE PLANS FOR CONTINUATION OF DISCHARGE PIPING
ELEVATOR SUMP AND PUMP DETAIL (SP-1)NO SCALE
9
P3.01
RELIEF VALVE (TEMP./PRESS.)
ROUTE TO DRAIN
TANK DRAIN
WALL MOUNTED STEEL ANGLE TANK SUPPORT
SAFE PANEWH-3
THERMOMETER
WALL
SERVICE SINK
TERMINATE WITH 2-INCH AIR GAP
ROUTE IN WALL
CW
HW
WATER HEATER DETAIL (EWH-3)NO SCALE
11
P3.01
MS-1
VACUUM BREAKER
ET-1
FOR CONTINUATION SEE FLOOR PLAN
7'-0"
CHECK VALVE
MERCURY FLOAT SWITCH
STEEL PIT COVER
4'-0"
GATE VALVE
PUMP (TYP. OF 2)
GUIDE RAILS
PUMP DISCHARGE (TYP OF 2) FOR CONTINUATION REFER TO FLOOR PLAN
SUMP VENT (FOR CONTINUATION REFER TO FLOOR PLAN)
PRE-CAST FIBERGLAS SUMP BASIN
I.E. -3.0'
BOTTOM OF BASIN (-7.0')
FINISHED FLOOR= 0.00'
1st PUMP SHUT-OFF (-5.5')
2nd PUMP -ON (-3.5')
HIGH WATER ALARM (-4.0')
DUPLEX SUMP AND PUMP DETAIL (SP-2)NO SCALE
10
P3.01
1st PUMP- ON (-4.5')