Mounting - Honeywell
Transcript of Mounting - Honeywell
![Page 1: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/1.jpg)
Device Switch
HS 30
Mounting
![Page 2: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/2.jpg)
![Page 3: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/3.jpg)
Contents
1
Contents
Contents 1
Overview 3Application 3
Mounting 4Laying cables 4Connecting loads and pushbuttons 5
Teach-in 8Activating the Teach-in mode at the switch module 8Assignment to Hometronic Manager HCM 200 9Assigning device switch HS 30 to Hometronic Manager as a
device 10Installing device switch HS 30 at Hometronic Manager as a
collection relay of thermostat control 11Installing device switch HS 30 at Hometronic Manager for
boiler request (HK 10) 14Successful Teach-in 15
Final mounting 16
Operating 17Device switch HS 30 as a collection relay of thermostat
control 18Device switch HS 30 as collection relay of boiler feedback
set HK 10 18
![Page 4: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/4.jpg)
Contents
2
Appendix 19Glossary 19Technical data 20Help with problems 21Information for the fitter 21
![Page 5: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/5.jpg)
Overview
3
Overview
For your information
Technical terms are explained in the glossary (Page 19). They areidentified in the text by an *.
ApplicationThe switch module HS 30 is a component of the Honeywell homeautomation system. It switches electrical loads* such as lamps, radios,humidifiers, etc.
For information on how the device switch can be used for thethermostat control, read from Page 18.For information on how the device switch can be used for theboiler request, read from Page 14.
The switch module is designed for surface mounting on a distributionbox of the device circuit.
The connected loads* can be operated by the following means:
• with the integrated pushbutton
• with an installed pushbutton/switch on site
• with the Hometronic Manager
• with the Hometronic Remote control
The switching state (ON/OFF) is indicated by an LED behind thetransparent button.
![Page 6: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/6.jpg)
Mounting
4
Mounting
Danger!
Danger to life through electric shock!
Live electrical contacts lie open while the module isbeing cabled. Touching a live contact causes criticalinjuries.
► All work may only be carried out by authorizedtechnical personnel.
► De-energize the corresponding fuse during all work onthe module*.
Caution!
The switch module has a radio receiver whose functioncan be impaired by metallic objects and radio devices.
► When selecting the operation site ensure that there issufficient distance to metallic objects such as metalcabinets and doors, concrete ceilings with iron latticesand radio devices such as radio headphones, etc.
Laying cables
► Lengthen the cables so that they protrude at least 10 cm out of thedistribution box.
![Page 7: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/7.jpg)
Mounting
5
► Remove the housing coverfrom the module.
► Lever the contact covers outwith a screwdriver.
► Insert all the cables throughthe openings in the housingbottom.
Connecting loads and pushbuttons
Both pushbuttons and switches can be connected to theswitch module. Pushbuttons should preferably be used fornew installations.
Caution!
Malfunctions due to contact erosion
► Replace old pushbuttons/switches by newpushbuttons.
► Only use pushbuttons which are designed for 230 Vand conform to the VDE guidelines.
![Page 8: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/8.jpg)
Mounting
6
The following figure shows the circuiting for connecting pushbuttons/switches and loads. The designations of the connections are alsoused in the further description of the mounting.
Ta: Pushbutton connection L: Phase
C: Common (relay grouping) N: Neutral conductor
NO: Normally Open PE: Protected earth conductor
NC: Normally Closed
The relay contacts (C, NC, NO) are floating contacts.
No terminal is planned for the protective earth conductor.
![Page 9: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/9.jpg)
Mounting
7
► Connect the pushbutton(switch) and the supplyvoltage to the right-handterminal block in accordancewith the schematic.
�� � ��
► Loop the PE conductor through the flush-mounted box to the motor.
► Connect the load to the left-hand terminal block inaccordance with theschematic.
�� ����
► First fasten the housing bottom temporarily at the intended mountingsite so that corrections can be carried out later if required.
► Switch on the switch module.
The LED at the switch module lights up green.
![Page 10: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/10.jpg)
Teach-in
8
Teach-inThe new Hometronic components first have to be assigned to theHometronic Manager before they can be taken into operation. Thisprocess is called the "Teach-in". The Hometronic Manager and thenew components exchange data during the procedure.
Activating the Teach-in mode at the switch module
► Keep the button at the switch module pressed for 10 seconds.
The LED flashes red regularly. The Teach-in mode at the switch
module is activated.
The Teach-in mode can be aborted by pressing the button atthe switching module briefly.
LED display at the switch module during the Teach-in
Display Meaning
LED flashes red Teach-in not carried out
LED blinks red Teach-in mode (duration 4 minutes)
LED off Teach-in successful
LED lights up red withshort breaks Teach-in failed
![Page 11: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/11.jpg)
Teach-in
9
Assignment to Hometronic Manager HCM 200
Switching to "Settings" submenu of Hometronic Manager
The Hometronic Manager is in automatic mode.
The display* at the Hometronic Managershows the standard display (example):
HOMETRONICWE 29.10.1999 11:15No Lifestyle activeLIVING 20.0 C
► Press the Dial button.
The cursor* flashes in the lowest line.
HOMETRONICWE 29.10.1999 11:15No Lifestyle activeLIVING 20.0 C
► Turn the Dial button to the right until"Menu" is selected.
► Press the Dial button.
The following text is displayed:
LIFESTYLETIME PROGRAMSDISPLAYSETTINGS
► Turn the Dial button to the left until"Settings" is selected.
► Press the Dial button.
The following text is displayed:
INSTALLATIONDE-INSTALLATIONFUNCTION EXTENSIONSENSOR FUNCTION
The Hometronic Manager is in the "Settings" submenu.
![Page 12: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/12.jpg)
Teach-in
10
Assigning device switch HS 30 to Hometronic Manager asa deviceIn the following example a humidifier is assigned to the switch module.
► Change to the "Settings" submenu as described on Page 9.
► Turn the Dial button until "Installation"is selected.
► Press the Dial button.
The following text is displayed:
HEATING/COOLINGSHUTTERSDEVICES/LIGHTSENSOR
► Turn the Dial button to the left untilthe "Devices/Light" submenu isselected:
HEATING/COOLINGSHUTTERSDEVICES/LIGHTSENSOR
► Press the Dial button.
The module names are displayed.
MODULE-1MODULE-2HUMIDIFIERCEILING LIGHT
► Turn the Dial button to the left untilthe corresponding module isselected, e.g.: "Humidifier".
MODULE-1MODULE-2HUMIDIFIERCEILING LIGHT
![Page 13: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/13.jpg)
Teach-in
11
► Press the Dial button.
An * appears after the "Humidifier"module.
MODULE-1MODULE-2HUMIDIFIER *CEILING LIGHT
► Activate Teach-in mode at the socket switching module within fourminutes (see Chapter "Activating the Teach-in mode at the switchmodule" on Page 8).
If "�" is displayed after a module name, this module hasalready been assigned to the Hometronic Manager. The pro-cess of assigning or changing module names is described inthe operating instructions of the Hometronic Manager.
Installing device switch HS 30 at Hometronic Manager asa collection relay of thermostat control
Installation of the collection relay (HS 20 or HS 30) has noeffect on the maximum number of devices at the HometronicManager HCM 200.
Example: Installing device switch HS 30 as a collection relay.
► Activate Teach-in mode at the HS 30 as described on Page 8.
► Change to the "Settings" submenu as described on Page 9.
![Page 14: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/14.jpg)
Teach-in
12
► Turn the Dial button until"Installation" is selected.
► Press the Dial button.
The following text is displayed:
HEATING/COOLINGSHUTTERSDEVICES/LIGHTSENSOR
► Turn the Dial button to the left until"Boiler request" is selected.
SENSORSETPOINT ADJUSTERROOM CONTROLBOILER REQUEST
► Press the Dial button.
The following text is displayed:
SWITCHING MODULEANTI-FREEZE SENSORTHERMOSTAT
► Turn the Dial button to the left until"Thermostat" is selected.
SWITCHING MODULEANTI-FREEZE SENSORTHERMOSTAT
► Press the Dial button.
An "*" appears after the"Thermostat" entry. The deviceswitch is assigned.
SWITCHING MODULEANTI-FREEZE SENSORTHERMOSTAT *
The socket switching module HS 30 is installed as a collection relay.
![Page 15: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/15.jpg)
Teach-in
13
Uninstalling collection relay
► Change to the "Settings" submenu (refer to Page 9).
► Turn the Dial button until "De-Installation" is selected.
► Press the Dial button.
The following text is displayed:
HEATING/COOLINGSHUTTERSDEVICES/LIGHTSENSOR
► Turn the Dial button to the left until"Boiler request" is selected.
SENSORSETPOINT ADJUSTERROOM CONTROLBOILER REQUEST
► Press the Dial button.
The following text is displayed:
SWITCHING MODULE *ANTI-FREEZE SENSORTHERMOSTAT *
► Turn the Dial button to the left until"Thermostat" is selected.
SWITCHING MODULE *ANTI-FREEZE SENSORTHERMOSTAT *
► Press the Dial button.
The "*" after the "Thermostat" entrydisappears.
SWITCHING MODULEANTI-FREEZE SENSORTHERMOSTAT
The collection relay is uninstalled.
![Page 16: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/16.jpg)
Teach-in
14
Installing device switch HS 30 at Hometronic Manager forboiler request (HK 10)
Installation of the collection relay (HS 20 or HS 30) has noeffect on the maximum number of devices at the HometronicManager HCM 200.
► Connect the switch module to the cable of the boiler control (refer toPage 5).
► Activate the Teach-in at the switch module (refer to Page 8).
► Change to the "Installation" submenu at the Hometronic Manager(refer to Page 8).
► Turn the Dial button to the left untilthe "Boiler demand" menu item isselected.
The following text is displayed:
SHUTTERSDEVICES/LIGHTSENSORBOILER DEMAND
► Press the Dial button.
The following text is displayed:
SWITCHING MODULE *ANTI-FREEZING SENSOR
After the Teach-in has been completed, the switch module is used forthe boiler demand.
![Page 17: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/17.jpg)
Teach-in
15
Successful Teach-inIf Teach-in was successful, the LED at the switch moduleextinguishes.
Failed Teach-in
If the LED at the switch module lights green with short breaks,the Teach-in has failed.
► Improve the transfer, avoid disturbances or shieldings, forexample, by:
– Wireless headphones, garage door opener, remotecontrols, metal parts
– If possible, change the position of the switchmodule.
► Repeat the Teach-in (starting from Page 8).
![Page 18: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/18.jpg)
Final mounting
16
Final mounting► Remove the housing cover again.
► Clamp the contact covers inthe housing bottom.
► Screw the housing bottomonto the flush-mounted boxor to the wall in accordancewith the drilling scheme.
![Page 19: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/19.jpg)
Operating
17
► Slide the housing cover ontothe housing bottom.
► Ensure that the housing coverlatches in.
Mounting has been completed.
OperatingThe switch position of the relay output of the HS 30 is operated bymeans of the built-in buttons or additional connected switches.
• LED green: contact C-NO (make contact).
• LED off: contact C-NC (break contact).
• LED red: communication error between Hometronic Manager and the switch module.
![Page 20: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/20.jpg)
Operating
18
Device switch HS 30 as a collection relay of thermostatcontrolA device switch HS 30 can be used (as a collection relay) forfeedback of the heat generation with thermostat control. The collectionrelay switches the boiler on as soon as a relay in a zone underthermostat control is activated.
Device switch HS 30 as collection relay of boiler feedbackset HK 10The Hometronic Manager sends a request signal to the collectionrelay HS 30 at a set boiler setpoint. The selectable boiler setpoint(18 °C is preset) is specified in the parameter list of the HCM 200.
The boiler setpoint is constantly compared with the room setpointtemperatures of the installed zones. The collection relay HS 30 isswitched on as soon as the room setpoint temperature of a zoneexceeds the boiler setpoint. The collection relay is switched off again ifall of the room setpoint temperatures are below the boiler setpoint.
For information on installing and setting the thermostatcontrol, refer to the operating instructions of the HometronicManager HCM 200.
![Page 21: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/21.jpg)
Appendix
19
Appendix
Glossary
Automatic modeStandard operating mode of theHometronic Manager. All theassigned areas are controlledby means of time programs.
Boiler demandSignal that the HometronicManager sends to the heatingboiler when the setpoint dropsbelow the minimum value.
Connected loadIntake power of the plugged-indevice.
LoadDevice which is connected tothe Hometronic component(e.g. coffee machine, lamp,radiator) and which consumespower.
LifestyleA certain combination of set-points.
Presence simulationThe operation course of the last7 days is repeated.
Time programA sequence of setpoints andcorresponding switching points.You specify a time program forevery module or every room.
Teach-inThe process of assigning amodel to the HometronicManager.
![Page 22: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/22.jpg)
Appendix
20
Technical data
Operating voltage 230 V AC, 50 Hz
Intake power 3 VA
Operating temperature 0...50 °C
Degree of protection IP 30
Storage temperature –20 °C...+70 °C
Maximum humidity 95 %, non-condensing
Limiting data of the connected load
Min. load 0.01 A / 5V DC/AC
Max. load: DC 8 A / 25 V
AC (cos Phi = 1) 10 A / 250 V
AC (cos Phi = 0.6) 4 A / 250 V
![Page 23: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/23.jpg)
Appendix
21
Help with problems
Problem/Display Cause Remedy
LED lights up redwith short breaks
Teach-in failed See "Improving thedata transfer" (P. 8).
Repeat the Teach-in.
No control byHometronicManager
Radio connection isdisturbed
See "Improving thedata transfer" (P. 8).
Connected switchmodules on or offautomatically
Time program*, Life-style* or presencesimulation* is activated
De-activate the timeprogram, Lifestyle orpresence simulation inthe HometronicManager
Information for the fitterAfter the radiator controller has been mounted, you should inform yourcustomer on the Hometronic System.
► Familiarize your customer with the operation of the Hometronic.
► Explain the manual operation of the components.
► Point out particular features and extension possibilities of therespective customer installation.
![Page 24: Mounting - Honeywell](https://reader031.fdocuments.net/reader031/viewer/2022020623/61f17968a9553f64e256112d/html5/thumbnails/24.jpg)
Honeywell AG
Böblinger Straße 17
D – 71101 Schönaich
Telephone (+49) 7031 637-300
This company is certificated to
The right is reserved to make modifications. This document is definitive for theenclosed product and replaces all previous publications.
No. 7157541 EN1H-0136 GE51R0802