AUTHORIZED STOCK LIST S-22 MOTOR LEAD WIRE Type SRML Silicone Rubber/Glass Braid • 600 Volts DESCRIPTION: Flexible stranded tinned copper, silicone rubber insulation, lacquered glass braid covering. RATINGS: Type SRML, 600 volts, 180°C continuous, 200°C intermittent. Size 18 -14 AWG are UL listed Type SFF-2 and sizes 12 & 10 AWG are UL listed AWM. Sizes 18-10 AWG are CSA listed SEWF-2. PART NUMBER 20652 20653 13528 13529 20659 20660 20661 20664 20665 20666 20668 20669 SIZE 18 18 16 16 14 14 14 12 12 12 10 10 TIN COPPER STRANDING 16/.0100 16/.0100 26/.0100 26/.0100 41/.0100 41/.0100 41/.0100 65/.0100 65/.0100 65/.0100 104/.0100 1 047. 01 00 APPROXIMATE DIMENSIONS INSUL .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .045 .045 O.D. .124 .124 .136 .136 .155 .155 .155 .179 .179 .179 .236 .236 STOCK COLORS Black White Black White Black White Red Black White Red Black White APPROX. WT. LBS./M FT. 12 12 16 16 22 22 22 32 32 32 52 52 STANDARD PUT-UP 500S 500S 500S 500S 500S 500S 500S 500S 500S 500S 500S 500S Notes: ULandCSA150°C rated only. 150°C rated as UL and CSA types. PORTABLE CORD AND CABLE UL/CSA American Mustang® Type SOOW 105°C to -50°C MSHA Weather, Water & Oil Resistant • 600 Volt DESCRIPTION: Stranded bare copper, oil and water resistant EPR insulation non-wicking fillers, cotton serve*, oil and moisture resistant, thermoset jacket. COLOR CODE: 2/C: Black, White 3/C: Black, White, Green 4/C: Black, White, Red, Green RATINGS: 600V, ULType SOOW, 105°C to -50°C, weather, water and oil resistant, suitable for extra hard usage indoor/ outdoor; CSA Type SOOW 105°C, weather, water and oil resis- tant, MSHA listed and OSHA acceptable. NOTES: The products having a green grounding conductor can be used for special applications as outlined in NFPA 70 (NEC) paragraph 501-4(b) Class 1 Div. 2 locations and paragraph 501-11 Class 1 Div. 1 and 2. Also suitable for the Canadian CEC Part 1 C22.1 latest edition paragraph 18-176 includ- ing sub-paragraphs (a) (b) and (c) Class 1 Zone 2. *18/2, 18/3 and 16/2 have paper separators. PART NUMBER 22187 22189 24270 22192 22194 24659 22197 22199 22202 22204 22207 22209 SIZE/ NO OF CONDS. 18/3 18/4 16/2 16/3 16/4 14/2 14/3 14/4 12/3 12/4 10/3 10/4 BARE COPPER STRANDING 41/.0063 41/.0063 65/.0063 65/.0063 65/.0063 41/.0100 41/.0100 41/.0100 65/.0100 65/.0100 104/.0100 104/.0100 APPROXIMATE DIMENSIONS INSUL. .030 .030 .030 .030 .030 .045 .045 .045 .045 .045 .045 .045 JKT. .060 .060 .060 .060 .060 .080 .080 .080 .095 .095 .095 .095 O.D. .360 .385 .365 .390 .420 .500 .524 .567 .600 .650 .655 .710 STOCK COLOR Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow APPROX. WT. LBS./M FT. 70 83 68 87 102 129 154 184 209 257 270 331 STANDARD PUT-UP 250S 250S 250S 250S/1000R 250S/1000R 250C 250C/1000R 250C/1000R 250C/1000R 250C/1000R 250C/1000R 250C/1000R 20 The data listed above is approximate and subject to normal manufacturing tolerances. These constructions are subject to change without notice.

Transcript of MOTOR LEAD WIRE - WESCO International LEAD WIRE Type SRML ... MSHA listed and OSHA acceptable....

AUTHORIZED STOCK LIST S-22

MOTOR LEAD WIRE

Type SRML • Silicone Rubber/Glass Braid • 600 VoltsDESCRIPTION: Flexible stranded tinned copper, silicone rubber insulation, lacquered glass braid covering.RATINGS: Type SRML, 600 volts, 180°C continuous, 200°C intermittent. Size 18 -14 AWG are UL listed TypeSFF-2 and sizes 12 & 10 AWG are UL listed AWM. Sizes 1 8 - 1 0 AWG are CSA listed SEWF-2.

PARTNUMBER

206522065313528135292065920660206612066420665206662066820669

SIZE

18181616141414

121 21 2

1010

TIN COPPERSTRANDING

16/.010016/.010026/.010026/.010041/.010041/.010041/.010065/.010065/.010065/.0100104/.01001 047. 01 00

APPROXIMATE DIMENSIONS

INSUL

.030

.030

.030

.030

.030

.030

.030

.030

.030

.030

.045

.045

O.D.

.124

.124

.136

.136

.155

.155

.155

.179

.179

.179

.236

.236

STOCKCOLORS

BlackWhiteBlackWhiteBlackWhiteRed

BlackWhiteRed

BlackWhite

APPROX. WT.LBS./M FT.

1 21216162222223232325252

STANDARDPUT-UP

500S500S500S500S500S500S500S500S500S500S500S500S

Notes:ULandCSA150°Crated only. 150°C ratedas UL and CSA types.

PORTABLE CORD AND CABLE

UL/CSA American Mustang® Type SOOW 105°C to -50°C • MSHAWeather, Water & Oil Resistant • 600 Volt

DESCRIPTION: Stranded bare copper, oil and water resistantEPR insulation non-wicking fillers, cotton serve*, oil and moistureresistant, thermoset jacket.COLOR CODE: 2/C: Black, White

3/C: Black, White, Green4/C: Black, White, Red, Green

RATINGS: 600V, ULType SOOW, 105°C to -50°C, weather,water and oil resistant, suitable for extra hard usage indoor/outdoor; CSA Type SOOW 105°C, weather, water and oil resis-tant, MSHA listed and OSHA acceptable.

NOTES: The products having a greengrounding conductor can be used for specialapplications as outlined in NFPA 70 (NEC)paragraph 501-4(b) Class 1 Div. 2 locationsand paragraph 501-11 Class 1 Div. 1 and 2.Also suitable for the Canadian CEC Part 1C22.1 latest edition paragraph 18-176 includ-ing sub-paragraphs (a) (b) and (c) Class 1Zone 2.*18/2, 18/3 and 16/2 have paper separators.

PARTNUMBER

221872218924270221922219424659221972219922202222042220722209

SIZE/NO OF

CONDS.

18/3

18/416/216/316/414/214/314/4

12/312/410/310/4

BARE COPPERSTRANDING

41/.006341/.006365/.006365/.006365/.006341/.010041/.010041/.010065/.010065/.0100104/.0100104/.0100

APPROXIMATE DIMENSIONS

INSUL.

.030

.030

.030

.030

.030

.045

.045

.045

.045

.045

.045

.045

JKT.

.060

.060

.060

.060

.060

.080

.080

.080

.095

.095

.095

.095

O.D.

.360

.385

.365

.390

.420

.500

.524

.567

.600

.650

.655

.710

STOCKCOLOR

YellowYellowYellowYellowYellowYellowYellowYellowYellowYellowYellowYellow

APPROX. WT.LBS./M FT.

70836887102129154184209257270331

STANDARDPUT-UP

250S250S250S

250S/1000R250S/1000R

250C250C/1000R250C/1000R250C/1000R250C/1000R250C/1000R250C/1000R

20 The data listed above is approximate and subject to normal manufacturing tolerances. These constructions are subject to change without notice.

AMERICAN MUSTANG®TYPES SOOW & SJOOWEPDM Insulation/CPE Jacket • Weather, Water and Oil Resistant •SOOW (600V) • SJOOW (300V) • 105°C to - 50°C

Indoor/OutdoorMSHA Listed

OSHA Acceptable

FEATURESFlexible, Bunch StrandedBare Copper Conductors

Non-WtckingElastomer Fillers*

• UL listed (file no. E7362)• CSA certified (file no. LL8825)• OSHA acceptable• Flame retardant (passes MSHA

Flame Test)• Black or high-visibility yellow jacket• Exceptional durability• Excellent resistance to oils, acids, chemi-

cals, water, ozone, extreme temperatures,cuts, tears and abrasion

• Sunlight resistant• SOOW can also be used for special

applications as outlined in NFPA 70(N.E.C.) paragraph 501.4(b) CL.1 Div. Zlocations and paragraph 501.11 CL.1 Div. 1and 2.

• UL and CSA listed for continuoussubmersion in water

APPLICATIONSType SOOWDesigned for extra hard usage on industrialequipment, heavy tools, motor and weldingleads, power extensions, portable machinery,sound equipment, portable stage lights, marinedockside power and mining applications.

Type SJOOWDesigned for hard usage with portableequipment, tools, small motors and powerextensions.

CONSTRUCTIONConductorsBare, annealed copper per ASTM B-3Flexible, bunch-stranded per UL-62

InsulationColor coded synthetic oil, ozone and waterresistant rubber (EPDM) UL-62

CablingConductors are assembled round (16/3 andlarger SOOW only) with non-wicking fillers asneeded and a cotton serve. Wax paper fillersutilized on 16/2, all 18 gauge and all SJOOWcords.

JacketOil resistant thermoset, CPE (black or yellow)UL-62

Temperature RangeUL 105°C (221 °F) to -50°C (-67°F)

Color Coding2/C: Black, White3/C: Black, White, Green*4/C: Black, White, Red, Green*'Green conductor is used for grounding purposes only.

,— Full Cotton Serve

Separator OptionalUnder Insulation • Oil, Ozone, and Water Resistant

EPDM InsulationOil and Sunlight ResistantThermoset, CPE Jacket

PART NUMBERSYELLOW BLACK-

CONDUCTORNO. AWG STRAND

DIMENSIONS (INCHES)INSUL. JACKET O.D. AMPS'

STANDARD"LENGTHSPUT-UP

SHIP WT.LBS7M FT

AMERICAN MUSTANG® • UL/CSA TYPE SOOW • 600V • 105°C-

2218722189242702219222194246592219722199281722220222204281662220722209

221852218622188221902219122193221952219622198222002220122203222052220622208

2 18 41x343 18 41x344 18 41x342 16 65x343 16 65x344 1 6 65x342 14 41x303 14 41x304 14 41x302 1 2 65x303 12 65x304 12 65x302 10 104x303 10 104x304 10 104x30

.030 .060 .340

.030 .060 .360

.030 .060 .385

.030 .060 .365

.030 .060 .390

.030 .060 .420

.045 .080 .500

.045 .080 .524

.045 .080 .567

.045 .095 .574

.045 .095 .600

.045 .095 .650

.045 .095 .623

.045 .095 .655

.045 .095 .710

10107

131310181815252520303025

1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.1 x 250' coil/ctn.

6978917694

1 1 0139164198189223270226283344

AMERICAN MUSTANG® • UL/CSA TYPE SJOOW • 300V • 105°C.

2347027917306372398427918341642398327919

3025126504232003371822263

--

2389625824

2 18 41X343 18 41x344 18 41x342 16 65x343 16 65x344 16 65x342 14 41x303 14 41x304 14 41x30

.030 .030 .280

.030 .030 .300

.030 .030 .325

.030 .030 .305

.030 .030 .325

.030 .030 .350

.030 .030 .335

.030 .030 .360

.030 .030 .390

10107

131310181815

1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.1 x 250' spool/ctn.

455971

6573877694

1 1 5

'Ampacities (Amps per conductor) are based on 30°C ambient temperature in air per the 1996 NEC, Table 400-5(A). Ampacities for3/C and 4/C cords assume 1 conductor is used as a ground or neutral and does not carry current.'Black jacketed cables not standard stock inventory."Long length reels available upon request. Consult local sales office.

Cable IdentificationType SOOW:Sizes 18 and 16 AWG—Ink print on JacketSizes 14 thru 10 AWG— Indent print on jacket

"American Mustang (size)/(no.)C -50°C SOOW105°C 600V water resistant (UL) P-136-40-MSHA - A.I.W. Corp. - CSA FT1"

Type SJOOW:Ink print on jacket

"American Mustang (size) AWG (no.)/C-50°C SJOOW 105°C 300V water

resistant (UL) P-136-49-MSHA -A.I.WCorp.-CSA FT1"

Notes:Wire passes cold bend testing at -55°C. American Mustang™ also meets or exceeds all ULrequirements for Types SO, SOO, SJO, and SJOO.

AMERICAN INSULATED WIRE CORP., P.O. Box 880, Pawtucket, Rl 02862-0880 • 401-726-0700 • FAX 401-723-1420