Mortals Electric Rider 6 · 2018. 5. 19. · MORTALS ELECTRIC - TECHNICAL RIDER TELCOSYSTEMS PO BOX...
Transcript of Mortals Electric Rider 6 · 2018. 5. 19. · MORTALS ELECTRIC - TECHNICAL RIDER TELCOSYSTEMS PO BOX...
MORTALS ELECTRIC - TECHNICAL RIDER
TELCOSYSTEMS PO BOX 174
3000AD ROTTERDAM
THE NETHERLANDS
+31 (0)6 166 14 770
WWW.TELCOSYSTEMS.NET
12-2008 1/7
TECHNICAL RIDER - TELCOSYSTEMS LIVE 2008 : MORTALS ELECTRIC - 5.1
MORTALS ELECTRIC is a 30 minute audiovisual performance, made to be experienced at high
velocity full impact, challenging the limits of human sensory perception. It is to be presented in
a cinematic environment; completely darkened, spatial accoustics optimized for surround
experience. Audience preferably seated.
1) Please contact TELCOSYSTEMS with audio and video specifications for approval at least two
weeks before show !
The PA should be of sufficient power for the venue with FOH EQ, extra sub bass and should be
properly calibrated for surround sound. All other FOH processors should be deactivated.
a) TELCOSYSTEMS will require two standard stage risers, joined in a row at their short sides
(2x1x0.8/1m WxDxH). The front area between the floor and the riser surface should be fully
covered with black molton cloth once the equipment has been set up. Due to the practical
impossibility of a proper surround monitoring system, the risers from which the artists will
perform should be placed within the 5.1 setup near the back of the PA / Speakers.
b) TELCOSYSTEMS will require one large 16:9 widescreen projection screen with a minimum
width of 6 mtrs. The projection surface should be of sufficient size for the venue.
c) TELCOSYSTEMS use a PC Laptop system for their video. The computer will provide a 720p
DVI-D signal (at a 1280 x 720 resolution). TELCOSYSTEMS will require one Christie DW4Kc or
equivalent (native 720p 3 Chip DLP) video projector (subject to approval), of sufficient ANSI
Lumens for the venue (at least 4000 ANSI Lumens).
d) TELCOSYSTEMS mix their video themselves. TELCOSYSTEMS require one 19"
widescreen TFT screen capable of displaying a 1280 x 720 resolution, plus the required
extended DVI-D fiber cable for connecting the screen to the video PC.
e) TELCOSYSTEMS mix their audio themselves. They will require one Allen & Heath WZ3
14:4:2 or equivalent audiomixer (subject to approval), equipped with at least 4 audio subgroup
outputs, plus the required cables for connecting the 6 6 !” TRS Jacks to the FOH. Provided
surround channels order will be : L (1) / R (2) / Ls (3) / Rs (4) / C (5) / LFE (6)
f) TELCOSYSTEMS will require one Behringer DI800 8 channel DI-Box or equivalent (subject
to approval), plus the required cables for connecting 6 !” TRS Jacks to the A& H WZ3 14:4:2
mixing desk.
g) Four power strips (at least 24 sockets total) for 220 volts European standard. ! beware of
grounding issues concerning the mixed use of audio and video equipment, best is to supply
separated power groups for the audio and video power supplies !
h) There should be a capable video-engineer present to oversee the set up, to assist in
adjusting the videoprojector and/or projection screen(s) during soundcheck and to oversee the
show. The engineer should not alter the projection settings once the artists start to play.
There should be a capable sound-engineer present to oversee the set up, to assist in adjusting
FOH sound during soundcheck and to oversee the show BUT all mixing will be done from the
stage. The engineer should not alter the mix or levels once the artists start to play.
i) Once the artist start to play ALL lighting, including emergency exits, should be dimmed, with
the exception of minimal stage light for the artists.
j) All provided equipment and cables should function properly.
MORTALS ELECTRIC - TECHNICAL RIDER
TELCOSYSTEMS PO BOX 174
3000AD ROTTERDAM
THE NETHERLANDS
+31 (0)6 166 14 770
WWW.TELCOSYSTEMS.NET
12-2008 2/7
2) TELCOSYSTEMS shall receive a minimum of sixty minutes free of all disturbances onstage for the
purpose of a sound and video check before the doors open.
3) TELCOSYSTEMS and their personnel shall maintain 100% control of the production and presentation
of the performance, which includes the following provisions:
a) Absolutely no audio recording, video recording, nor radio broadcasting will be allowed
during the performance unless prior written permission has been granted by TELCOSYSTEMS
or their representative. The PURCHASER agrees to confiscate all unauthorized recording
equipment, and to hold said equipment until the completion of the performance.
b) The volume of the performance as well as the lighting during the performance, both onstage
and through the house system shall be determined exclusively by TELCOSYSTEMS (within the
limits of equipment capacity).
4) TELCOSYSTEMS require the following equipment :
Video
- 1 x Christie DW4Kc video projector
- 1 x Widescreen projection screen (at least 6 meters wide)
- 1 x Widescreen TFT flatscreen (1280 x 720 native resolution)
- All necessary cables and specials (items marked red in hardware layout)
Audio
- 1 x Allen & Heath WZ3 14:4:2
- 1 x Behringer DI-800 UltraDI-PRO 8-channel rack
- A very powerfull P.A. system with 6 full frequency Stacks and extra SUB
- All necessary cables and specials (items marked red in hardware layout)
Stage
- 2 x stage riser (4 m. total) placed in centre of 5.1 PA setup
- 4 x 6-socket power strips
Please refer all technical questions to :
Telcosystems Gideon Kiers
Email [email protected]
Web www.telcosystems.net
Phone +31 6 16614770
Video PC Powerbook G4Macbook Pro
Fireface 400 Fireface 400Multiface
BCF 2000
Pocket ControlPocket Control
DI800
MIDIFIREWIRE FIREWIRE
USB
FIREWIRE MIDI
ADAT TOSLINK
[ 6 ] 1/4" TRS JACK
MULTICABLE
DVI-D 1280 x 720 p
5.1 SURROUND & FOH
1280 x 720 TFT DVI
D
V
I
CHRISTIE DW4Kc
HARDWARE SCHEMATICS
MORTALS ELECTRIC
TECHNICAL RIDER
TELCOSYSTEMSP.O. BOX 174
3000 AD ROTTERDAM
THE NETHERLANDS
+31 (0) 6 166 144 770
WWW.TELCOSYSTEMS.NET
A&H WZ3 14:4:2
[ 6 ] 1/4" TRS JACK
[ 6 ] 1/4"
TRS JACK
AUDIO ROUTING
MORTALS ELECTRIC
TECHNICAL RIDER
TELCOSYSTEMSP.O. BOX 174
3000 AD ROTTERDAM
THE NETHERLANDS
+31 (0) 6 166 144 770
WWW.TELCOSYSTEMS.NET
SPATIAL SETUP 01
MORTALS ELECTRIC
TECHNICAL RIDER
TELCOSYSTEMSP.O. BOX 174
3000 AD ROTTERDAM
THE NETHERLANDS
+31 (0) 6 166 144 770
WWW.TELCOSYSTEMS.NET
SPATIAL SETUP 02
MORTALS ELECTRIC
TECHNICAL RIDER
TELCOSYSTEMSP.O. BOX 174
3000 AD ROTTERDAM
THE NETHERLANDS
+31 (0) 6 166 144 770
WWW.TELCOSYSTEMS.NET
SPATIAL SETUP 03
MORTALS ELECTRIC
TECHNICAL RIDER
TELCOSYSTEMSP.O. BOX 174
3000 AD ROTTERDAM
THE NETHERLANDS
+31 (0) 6 166 144 770
WWW.TELCOSYSTEMS.NET