Monitoring Osteoporosis Therapy F

35
Monitoring Monitoring Osteoporosis Therapy Osteoporosis Therapy Dr Omar Hussein Professor of Radiology Ain Shams University

Transcript of Monitoring Osteoporosis Therapy F

Page 1: Monitoring Osteoporosis Therapy F

Monitoring Monitoring Osteoporosis TherapyOsteoporosis Therapy

Dr Omar HusseinProfessor of Radiology

Ain Shams University

Page 2: Monitoring Osteoporosis Therapy F

Clinical QuestionsClinical Questions

Why monitor osteoporosis therapy?

Will the results of the repeat DXA scan change your management?

If a repeat DXA scan is ordered, how do you know if the change is real?

Page 3: Monitoring Osteoporosis Therapy F

Rationale Rationale

Many factors that are not clinically apparent could lead to a suboptimal response to therapy :

Long-term compliance and persistence with therapy is poor; only about 50 percent of patients who begin an osteoporosis drug continue therapy for at least one year.

Some patients do not maintain a sufficient intake of calcium or vitamin D to achieve the full benefit of therapy.

 

Page 4: Monitoring Osteoporosis Therapy F

Rationale Rationale Malabsorption caused by a variety of GIT

disorders, including asymptomatic celiac disease, may impair treatment effect.

Other conditions with adverse skeletal effects, such as multiple myeloma or increased thyroid hormone levels, may be present but undetected before therapy, or may develop during therapy.

Page 5: Monitoring Osteoporosis Therapy F

RationaleRationale

Various circumstances may affect decisions about continuing or modifying treatments◦Prognosis◦Responsiveness to treatment◦Possibility for changing to a lower-risk

intervention◦Resident satisfaction with the benefits of—or

concern about complications related to—treatment

5

Page 6: Monitoring Osteoporosis Therapy F

BMD measurement:BMD measurement:

Raisz L. N Engl J Med 2005;353:164-171

1. Dual-Energy X-Ray Absorptiometry:

Results expressed as• T-SCORE is the number of SD the

measurement is above or below the YOUNG-NORMAL MEAN BMD.

• Z-SCORE is the number of SD the measurement is above or below the AGE-MATCHED MEAN BMD.

Sites used for measurement per WHO criteria:

• Total proximal femur• Femoral neck• Lumbar spine• 33percent(1/3rd) radius

Peripheral skeletal sites predict global # risk, however not used in WHO/FRAX criteria therefore limited value. Changes to therapy at these sites are slow.

Page 7: Monitoring Osteoporosis Therapy F

SQ Mild SQ Severe

1

1

3

3

Page 8: Monitoring Osteoporosis Therapy F

Lateral Vertebral Lateral Vertebral Assessment (using DXA):Assessment (using DXA):

Qualitative and quantitative

Page 9: Monitoring Osteoporosis Therapy F

Semi-quantitative grading (Genant et al 1993)

Normal

Anterior Middle Mild fracture

Middle Moderate fracture

MiddleSevere fracture

Anterior

Anterior

Posterior

Posterior

Posterior

(Source: Genant HK et al, JBMR 1993; 8:1137-1148)

Grade

0

1 (~20-25%)

2 (~25-40%)

3 (~40%)

Page 10: Monitoring Osteoporosis Therapy F

Using BMD to Monitor Therapy in Using BMD to Monitor Therapy in Treating Osteoporosis: Treating Osteoporosis:

Page 11: Monitoring Osteoporosis Therapy F

Lewiecki  EM, Watts  NB.  Assessing response to osteoporosis therapy.  Osteoporos Int.   2008;19(10):1363–1368.

Page 12: Monitoring Osteoporosis Therapy F
Page 13: Monitoring Osteoporosis Therapy F
Page 14: Monitoring Osteoporosis Therapy F
Page 15: Monitoring Osteoporosis Therapy F

What Is Precision Error?What Is Precision Error?PE reflects the reproducibility of a

measurement when performed under identical circumstances in the setting of no real biologic change.

Page 16: Monitoring Osteoporosis Therapy F

Factors that affect precision for Factors that affect precision for DXA ScansDXA Scans

Equipment Number of MeasurementsOperator Dependent Variables

Page 17: Monitoring Osteoporosis Therapy F

How To Calculate Precision?How To Calculate Precision?Scan

◦15 individuals 3 times

◦30 individuals 2 times

Use patients representative of your typical patient population

Reposition between each scanFrom these measurements radiologist is

able to calculate precision for specific center

Bonnick SL, et al. J Clin Densit 2001; 4:105

Page 18: Monitoring Osteoporosis Therapy F

Precision is Important because it Precision is Important because it allows Least Significant Change allows Least Significant Change

(LSC) to be calculated(LSC) to be calculated

Page 19: Monitoring Osteoporosis Therapy F

What is Least Significant What is Least Significant Change (LSC)?Change (LSC)?

Precision error at your center

Desired confidence level (95%)

LSC = 2.8 x precision error

Only changes exceeding 2.8 times the precision error can be considered clinically significant within the 95% confidence interval.

Page 20: Monitoring Osteoporosis Therapy F

Spine BMD with antiresorptive agents Dotted line indicates LSC at 1 and 2 years

Deal, Current Rheumatology Reports, 2002 - adapted from McClung

Page 21: Monitoring Osteoporosis Therapy F

Hip BMD with antiresorptive agents- Dotted line indicates LSC at 3 years

Deal, Current Rheumatology Reports, 2002 - adapted from McClung

Page 22: Monitoring Osteoporosis Therapy F

Confounding Variables that affect Confounding Variables that affect

DXA ScanningDXA Scanning

Aortic calcifications OsteophytesCompression fracturesSkeletal diseases ie. Pagets disease

Page 23: Monitoring Osteoporosis Therapy F

Current Current recommendations for recommendations for

monitoring osteoporosis monitoring osteoporosis therapytherapy

Page 24: Monitoring Osteoporosis Therapy F
Page 25: Monitoring Osteoporosis Therapy F
Page 26: Monitoring Osteoporosis Therapy F
Page 27: Monitoring Osteoporosis Therapy F

Bone MarkersBone Markers

Page 28: Monitoring Osteoporosis Therapy F
Page 29: Monitoring Osteoporosis Therapy F

Bone markersBone markers

Diagnosis of osteoporosis is not based on evaluation of bone markers, and bone mineral density (BMD) assessment is still the criterion standard for evaluation and diagnosis. 

Page 30: Monitoring Osteoporosis Therapy F

A study done by Kumar et al, 2008 showed that osteocalcin showed a significant correlation with BMD and other bone markers did not correlate with the underlying BMD. Even though changes in bone metabolism cannot be identified by the determination of a single bone marker, improved biochemical measurement may provide early information about osteoporosis. Because of the variability of bone turnover markers, BMD determination still remains the best modality currently available for evaluation of osteoporosis

Bone Markers and Bone Density, Endocr Pract  2008;14(No. 9)

Page 31: Monitoring Osteoporosis Therapy F

Several studies confirmed that short-term reductions in bone turnover were associated with a reduction in vertebral and/or non-vertebral fracture risk in women.

Clin Biochem Rev. 2006 August; 27(3): 123–138.Biochemical Markers of Bone Turnover Part II: Clinical Applications in the Management of Osteoporosis

Page 32: Monitoring Osteoporosis Therapy F

There are data suggesting that biochemical markers of bone turnover are useful tools to evaluate therapeutic effects after a relatively short period of time, and that serial measurements of bone markers may help to decide whether or not a patient responds to a specific antiresorptive treatment. 

As bone turnover markers, in particular indices of bone resorption, decrease rapidly after initiation of treatment within three to six months, they might represent useful surrogate markers for monitoring patient compliance. Only few data, however, are available to support this theoretical approach. 

Clin Biochem Rev. 2006 August; 27(3): 123–138.Biochemical Markers of Bone

Turnover Part II: Clinical Applications in the Management of Osteoporosis

Page 33: Monitoring Osteoporosis Therapy F

To concludeTo conclude

Precision and LSC must be considered to obtain reliable results from repeat DXA scans.

Changes in BMD are more precisely measured at sites of trabecular bone, ie. the spine

Increase in BMD is only part of the fracture risk reduction story.

Page 34: Monitoring Osteoporosis Therapy F

To ConcludeTo Conclude

A statistically significant BMD loss may lead to further evaluation and possibly a change in treatment.

The strategy of monitoring therapy with BMD testing is supported by the medical evidence, consistent with clinical practice guidelines, and makes good clinical sense.

Page 35: Monitoring Osteoporosis Therapy F