Module Three Chapters 7, 8, & 9
description
Transcript of Module Three Chapters 7, 8, & 9
![Page 1: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/1.jpg)
Module ThreeChapters 7, 8, & 9
![Page 2: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/2.jpg)
Chapter 7
Site Assessment and Weather
![Page 3: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/3.jpg)
PREPARING FOR SOIL FUMIGATION
• The first step in such preparation is site assessment – evaluate the suitability of the site.
• Site assessment will help to:– protect people and the environment.– choose soil management methods, fumigants,
and application techniques..– maximize fumigant efficacy.
![Page 4: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/4.jpg)
SITE ASSESSMENT• Determine if the proposed application site
is near areas where people gather (e.g., residences, businesses, public meeting sites, hospitals, or schools).
• Nearness to occupied structures does not necessarily preclude fumigation (except for some occupied difficult-to-evacuate sites). However, it does require additional planning.
![Page 5: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/5.jpg)
SITE ASSESSMENT• Evaluate the site’s topography (surface features).
Under stable air conditions, if fumigant vapors travel offsite, they can collect and concentrate down slope.
• When making a soil fumigant application, consider the potential offsite movement to surrounding areas due to changes in topography.
• Take additional precautions if these areas contain structures occupied by humans or animals, or if you will need to enter them during or shortly after the fumigation. Such precautions include wearing appropriate PPE and monitoring for fumigant air concentrations.
• Identify and locate field obstacles that may pose risk to the applicator or application equipment.
![Page 6: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/6.jpg)
SOIL CHARACTERISTICS• Environmental and field conditions affect
both the success and the safety of the fumigation.
• Be aware that fumigant labels carry specific directions for mandatory GAPs to prepare soil before fumigation.
• Soil GAPs refer to soil preparation, condition, moisture, and temperature.
![Page 7: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/7.jpg)
PREPARING FOR SOIL FUMIGATION
![Page 8: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/8.jpg)
PREPARING FOR SOIL FUMIGATION
![Page 9: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/9.jpg)
WEATHER FORECAST• Present and immediate postapplicaton weather conditions
affect fumigant vapors that escape from the soil. These vapors can move offsite and expose nearby people, animals, and plants.
• This includes both weather conditions at the start of the application and immediately after the application.
• The certified applicator supervising the application must check the National Weather Service (NWS) forecast before a soil fumigation.
• This check will help determine if unfavorable weather conditions may occur when a fumigation is planned— and whether the application should proceed.
![Page 10: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/10.jpg)
WEATHER FORECASTCheck the weather forecast:• On the day of and preceding the start of
the application.
• Each day during the application if the time elapsed from the start of the application until the application is complete is greater than 24 hours.
![Page 11: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/11.jpg)
ONCE AGAIN
![Page 12: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/12.jpg)
WEATHER FORECAST• You may obtain detailed NWS forecasts for
local weather conditions, wind speed, and air stagnation advisories online at: - http://www.nws.noaa.gov,- on National Oceanic and Atmospheric Administration (NOAA) weather radio,- or by contacting your local NWS forecasting office.
![Page 13: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/13.jpg)
TEMPERATURE INVERSIONS• Temperature inversions are often to blame for human
exposure to fumigants.• In an inversion, warmer (lighter) air rises above cooler
(heavier) air, which settles near the ground. Under inversion conditions, normal air mixing does not take place; fumigant vapors settle and concentrate near the ground.
• When an inversion happens, fumigant vapors often move offsite with low-level air movement or settle in low-lying areas.
• Low-level winds (less than 2 mph) are highly unpredictable in the direction they move.
![Page 14: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/14.jpg)
TEMPERATURE INVERSIONSClues that inversion conditions exist include:• Road dust that hangs in the air and has
little upward or lateral movement.• Ground fog or smog that remains
concentrated with little upward movement.• Smoke from the ground that rises little,
flattens out, and moves as a concentrated cloud.
![Page 15: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/15.jpg)
TEMPERATURE INVERSIONS
![Page 16: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/16.jpg)
TEMPERATURE INVERSIONS• Temperature inversion conditions typically start an
hour before sunset and continue past sunrise. • They may persist as late as noontime. However,
inversions can persist all day long. • Inversion conditions are common on nights with
limited cloud cover and little to no wind. • Look for ground fog, smog, or smoke that flattens out
below a ceiling layer and moves sideways in a concentrated cloud. (Note that coastal fog generated by inland movement of sea air masses does not necessarily indicate temperature inversions.)
![Page 17: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/17.jpg)
TEMPERATURE INVERSIONSAir Stagnation Advisory• Most labels (except 1,3-D only formulations)
prohibit an application to proceed if an air stagnation advisory issued by the NWS is in effect for the area anytime from the start of application until 48 hours after the application is scheduled to be complete.
• If an air stagnation warning occurs during the application, the application must stop.
![Page 18: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/18.jpg)
ONCE AGAIN
![Page 19: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/19.jpg)
LIGHT WINDS• Most labels (except 1,3-D only
formulations) prohibit an application to proceed if light wind conditions (less than 2 mph) are expected to persist for more than 18 consecutive hours from the time the application starts until 48 hours after the application is scheduled to be complete.
![Page 20: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/20.jpg)
Review Questions
![Page 21: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/21.jpg)
Which of the following items must you consider during a site assessment?
1 2 3
0% 0%0%
1. Topography.2. Geneology.3. Geology
![Page 22: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/22.jpg)
A fumigant handler is planning to apply a fumigant to a sloping field. The loam soil contains some
surface crop residue and 60 % available soil moisture. Which site or soil characteristic should be
the handler’s biggest concern?
1 2 3
0% 0%0%
1. The steepness of the slope.
2. The amount of crop residue.
3. The available moisture.
![Page 23: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/23.jpg)
Which of the following predicted weather conditions will prohibit a fumigant
application?
1 2 3
0% 0%0%
1. If wind speed of 3 mph or less persists for 18 consecutive hours from the start of the application until 48 hours after the application is scheduled to end.
2. If an air stagnation advisory will occur any time from the start of the application until 48 hours after the application is scheduled to end.
3. If wind speed between 5 and 10 mph occurs during a solid stream chemigation application.
![Page 24: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/24.jpg)
Which two statements about temperature inversions are correct?
1 2 3
0% 0%0%
1. (1) They typically start an hour before sunset; (2) they are common on nights with limited cloud cover
2. (1) Cooler air is above warmer air; (2) normal air mixing does not take place.
3. (1) Warmer air rises above cooler air; (2) wind speed exceeds 7 mph.
![Page 25: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/25.jpg)
![Page 26: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/26.jpg)
Fumigant Management Plan (FMP)
• A Fumigant Management Plan (FMP) is a site-specific plan prepared before any fumigation begins.
• An FMP is intended to ensure that all aspects of a safe and effective fumigation have been planned ahead of the actual work.
• It captures how a certified applicator is planning to comply with label requirements and serves as a record of compliance.
![Page 27: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/27.jpg)
Fumigant Management Plan (FMP)
![Page 28: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/28.jpg)
• Anyone may develop the FMP. However,the certified applicator-in-charge ofthe application must, before beginningthe fumigation: review, sign, and datethe plan to verify that it is accurate, up to date, and complies with the label.
Fumigant Management Plan (FMP)
![Page 29: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/29.jpg)
You must record all of the following elements ina soil fumigation FMP:• Certified applicator and owner information.• General site information.• General application information.• Tarp plan (if tarp is used).• Soil conditions.• Buffer zones.
Fumigant Management Plan (FMP)
![Page 30: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/30.jpg)
You must also record all of the following elements ina soil fumigation FMP:
• Emergency response plan.• Posting of fumigant treated area and buffer zone
signs.• Emergency preparedness and response measures
(if applicable).• State and/or tribal lead agency advance notification.• Communication plan.
Fumigant Management Plan (FMP)
![Page 31: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/31.jpg)
You must also record all of the following elements in a soil fumigation FMP:
• Fumigant handler information, training, and PPE.• Air-monitoring plan.• Chemigation and drip application monitoring
information (if applicable).• Good agricultural practices.• Pesticide product labels and Material Safety Data
Sheets (MSDSs).
Fumigant Management Plan (FMP)
![Page 32: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/32.jpg)
![Page 33: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/33.jpg)
![Page 34: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/34.jpg)
![Page 35: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/35.jpg)
![Page 36: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/36.jpg)
![Page 37: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/37.jpg)
![Page 38: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/38.jpg)
![Page 39: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/39.jpg)
![Page 40: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/40.jpg)
Fumigant Management Plan (FMP)
![Page 41: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/41.jpg)
FMP DOCUMENTATION AND RECORDKEEPING
• A certified applicator or other worker must prepare and review an FMP before a soil fumigation begins.
• The FMP must be kept on site during all handler activities.
• It must also be made immediately available to handlers; local, state, federal, and tribal enforcement personnel; and emergency responders.
• Both the certified applicator and the property owner/lessee must keep a copy of the FMP on file for two years from the date of the application.
![Page 42: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/42.jpg)
GROWERS MAY CHOOSE TO DEVELOP A FARM-WIDE FMP
A farm-wide FMP allows growers to:• keep the information common to all application blocks on the
farm in one document and in one place (for example, in the first section of a binder).
• include information about the certified applicator, owner, fumigant handlers, and emergency response plans.
• include details on the product, tarps, and/or application method.
• Information unique to each separate application block is recorded in different sections. This might include the location and size of each application block, buffer sizes, application dates, weather, and soil conditions.
![Page 43: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/43.jpg)
GROWERS MAY CHOOSE TO DEVELOP A FARM-WIDE FMP
![Page 44: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/44.jpg)
Fumigant Management Plan (FMP)
![Page 45: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/45.jpg)
Fumigant Management Plan (FMP)Postapplication Summary (PAS)
![Page 46: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/46.jpg)
Fumigant Management Plan (FMP)Postapplication Summary (PAS)
![Page 47: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/47.jpg)
FMP/PASSoil fumigant labels require that:• both the certified applicator and the
owner/operator retain the FMP and PAS for two years.
Note: Federal RUP application record retention requirements are also two years.
![Page 48: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/48.jpg)
Additional Information:• Several templates and web-based systems
exist for preparing FMPs and PASs.• These are available from EPA, pesticide
registrants, and commercial entities.• Some of the commercially-available
programs may contain enough information to meet the application record, FMP, and PAS reporting requirements.
![Page 49: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/49.jpg)
Review Questions
![Page 50: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/50.jpg)
The certified applicator-in-charge of the fumigation is the only person who may
prepare a fumigant management plan (FMP).
1 2
0%0%
1. True2. False
![Page 51: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/51.jpg)
During a soil fumigation, how long must the FMP be kept on site?
1 2 3
0% 0%0%
1. Only while fumigant is being applied.
2. Only at the start of the application.
3. During all handler activities.
![Page 52: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/52.jpg)
Select the two statements that describe how the postapplication summary (PAS) differs from the fumigant management plan
(FMP)?
1 2 3
0% 0%0%
1. (1) PAS contains agreements made with neighbors; (2) PAS documents if tarps were damaged
2. (1) PAS may be prepared by anyone; (2) PAS includes the weather forecast during and after the application.
3. (1) PAS records any deviations from the FMP; (2) PAS reports any incidents or complaints.
![Page 53: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/53.jpg)
Both the certified applicator and the property owner/lessee must keep a copy of the FMP on file for two years from the
date of the application.
1 2
0%0%
1. True2. False
![Page 54: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/54.jpg)
Chapter 9Buffer Zones and
Posting Requirements
![Page 55: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/55.jpg)
Buffer Zones• Buffer zones are required for most fumigations. • A buffer zone is a restricted-access area surrounding
the application block. • It must remain in place
– From the start of the application until– 48-hours after for most products.
• To protect bystanders from fumigant exposure.• Only trained fumigant handlers wearing appropriate
PPE may be in the buffer zone, with the exception of vehicular or bicycle traffic on roadways.
![Page 56: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/56.jpg)
Application Block• The area being treated during the fumigation • An application block can be a
– field, – contiguous fields, – a greenhouse, or – a series of beds or planting strips undergoing fumigation.
• The perimeter of the application block is the border that connects the outermost edges of the total area treated with the fumigant.
• The size of the application block is the area within the perimeter of the field where the fumigant is applied.
• Buffer zones are established around the application block and extend outward from the perimeter of the treated area equally in all directions.
![Page 57: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/57.jpg)
![Page 58: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/58.jpg)
Buffer Zone Period• The buffer zone period extends from
– the time that the fumigant application begins– until 48 hours after the application ends
• One exception to the 48-hour period is for products formulated with 1,3-D as the only active ingredient, which have a seven day buffer zone period.
• Methyl bromide labels require a longer buffer zone period or a second buffer zone for certain tarps.
• Read labels carefully to make sure you understand buffer zone.• During the buffer zone period, all nonhandlers, field workers,
nearby residents, pedestrians, and other bystanders must stay out of the buffer zone with one exception: people in transit (vehicular and bicycle) on roadways may move through the buffer zone.
![Page 59: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/59.jpg)
Buffer Zone Size• Labels include tables showing
required buffer zone sizes. • The minimum buffer distance
noted on most labels is 25 feet. • Buffer zone size is based on
several factors:– Fumigant being used.– Application rate.– Application block size.– Application method.
• Use these tables to determine the size.
• Labels include separate tables for different application methods.
• Application is prohibited for rates or block sizes that exceed those presented in the buffer zone table.
• Roundup to the nearest rate or block size.
Buffer Zone Distances in Feet
Shank Injection Application
60 acres
80 acres
100 acres
120 acres
160 acres
80 lbs a.i./acre
200 275 350 400 533
120 lbs a.i./acre
500 600 700 800 1067
160 lbs a.i./acre
750 925 1050 1250 1667
200 lbs a.i./acre
938 1156 1313 1563 2083
240 lbs a.i./acre
1125 1388 1575 1875 2500
![Page 60: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/60.jpg)
Buffer Zone Credits• Buffer zone credits on fumigant labels
allow reductions in buffer zone distance.• Here are several factors that may earn
buffer zone credits:– Use of specific high-barrier tarps– Soil conditions (e.g., soil organic matter
and soil temperature).– Use of certain application equipment.
![Page 61: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/61.jpg)
Buffer Zone Credits• There is a maximum buffer zone reduction that can
be earned using these credits, for example:– 80% maximum credit for methyl bromide,
chloropicrin, metam sodium, and metam potassium.– 40% maximum credit for dazomet.
• The certified applicator must record certain information on buffer zones in the FMP: – the buffer zone distance, – any credits (if earned), and – any measurements taken to determine the size of the
buffer zone.
![Page 62: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/62.jpg)
Remember these two important factors about buffer zones:
• If, after applying all applicable buffer zone credits, the buffer zone is greater than a half mile (2,640 ft), then the application is prohibited.
• In all cases where buffer zones are required, the minimum buffer zone allowed is 25 feet.
![Page 63: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/63.jpg)
Overlapping Buffer Zones• Fumigant labels specify that
– buffer zones of multiple application blocks may overlap only if at least 12 hours pass between • the completion of the first
application and • the start of the second.
![Page 64: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/64.jpg)
![Page 65: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/65.jpg)
Other Buffer Zone Restrictions
• Residential and Business Areas:– Buffer zones may not include residential areas
unless the occupants sign a written agreement to voluntarily vacate the buffer zone during the buffer zone period.
• Other Structures:– Buffer zones must not include buildings used for storage
(such as sheds, barns, and garages), unless both of the following are true:
• The storage buildings are not occupied during the buffer zone period.
• The storage buildings do not share a common wall with an occupied structure.
![Page 66: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/66.jpg)
Roadways, Rights-of-Way, and Transit through Buffer Zones
• A buffer zone may include roadways and/or rights-of-way only if all three of the following are true:– The area is unoccupied during the buffer zone period.– Entry by nonfumigant handlers is prohibited.– Certified applicators comply with all local laws and regulations.
• Only vehicular and bicycle traffic are allowed to travel through buffer zones during the buffer zone period.
• Bus stops or other areas where people wait for public transportation must not be included in a buffer zone.
![Page 67: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/67.jpg)
Publically Owned or Operated Areas
• A buffer zone may include publically owned or operated areas (such as a public park) if all of the following are true:– The area is unoccupied during the buffer zone period.– Nonfumigant handlers are prohibited from entering.– Certified applicators comply with all local laws and
regulations.– The state or local authorities responsible for the
management and operation of the area provide written permission.
![Page 68: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/68.jpg)
Other Agricultural Areas• A buffer zone may include an agricultural
area owned by another person if both of the following are true:– Buffer zones for different fumigations do not
overlap.– The owner or operator provides written
agreement that no one will enter the buffer zone during the buffer zone period.
![Page 69: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/69.jpg)
Signage and Posting Requirements• Most soil fumigant labels require two types of postings:
– Treated Area Posting, and – Buffer Zone Posting.
• All require treated area posting according to WPS requirements. Most require buffer zone posting (except 1,3-D only products).
• Some of the information on these signs is the same:– contact information for the certified applicator and – details of the product to be used.
• However, they are two different sets of signs with two different posting requirements.
![Page 70: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/70.jpg)
Treated Area Posting• Fumigant treated area signs are
posted at the perimeter of the application block.
• The information on the signage is different from regular WPS signs.– Skull and crossbones symbol.– DANGER/PELIGRO.– Area under fumigation, DO NOT
ENTER/NO ENTRE.– [Name or names of the fumigant
active ingredient] fumigant in use.
– [Name of the product].– Date and time of fumigation (start
and finish).– Date and time entry-restricted
period is over.– Name, address, and telephone
number of the certified applicator-in-charge of the fumigation
![Page 71: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/71.jpg)
Treated Area Posting• For soil fumigations, the fumigant treated
area sign replaces the WPS no-entry sign. • Fumigant treated area signs must be:
– Posted at all entrances to the application block.– Posted no sooner than 24 hours before
application.– In place for at least the duration of the entry-
restricted period.– Removed within three days after the end of the
entry-restricted period.
![Page 72: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/72.jpg)
Buffer Zone Posting• Buffer zone signs warn workers and bystanders about
– the location of the buffer zone, – entry prohibition, and – other important information.
• Buffer zone signs are available at fumigant points of sale.
• You can also download templates from the EPA’s soil fumigant website:
http:// www.epa.gov/fumiganttraining/.
![Page 73: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/73.jpg)
Buffer Zone Signs• Buffer zone signs must include all of the following:
– “Do Not Walk” symbol.– DO NOT ENTER/NO ENTRE.– [Name of fumigant active ingredient]; [name of product]; fumigant buffer
zone.– Contact information for the certified applicator-in-charge of the fumigation.
• Buffer zone signs must be:– Posted at all points of entry into the buffer zone and along likely travel
routes (roads, sidewalks, walking paths, and bike trails), facing in the direction that people approach the area.
– Legible.– A minimum of 14 by 16 inches, with letters a minimum of 1 inch.– Posted no sooner than 24 hours before application.– In place until end of buffer zone period.– Removed within three days after the end of buffer zone period.
![Page 74: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/74.jpg)
![Page 75: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/75.jpg)
Buffer Zone sign
![Page 76: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/76.jpg)
![Page 77: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/77.jpg)
Difficult-to-Evacuate Sites• Some sites are difficult to evacuate in cases of an
accident or emergency. Product labels prohibit fumigant applications near occupied difficult-to-evacuate sites, which include the following:– Schools (pre-kindergarten through grade 12).– State-licensed daycare centers.– Nursing homes.– Assisted-living facilities. – Hospitals.– In-patient clinics.– Prisons.
![Page 78: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/78.jpg)
![Page 79: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/79.jpg)
![Page 80: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/80.jpg)
Review Questions
![Page 81: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/81.jpg)
Select two practices that may earn buffer zone credits to reduce buffer zone distances:
1 2 3
0% 0%0%
1. (1) Applying at lower soil temperatures; (2) using certain application equipment.
2. (1) Selecting certain soil fumigants; (2) applying to highly organic soils.
3. (1) Applying at certain times of the day; (2) using a water seal over tarps.
![Page 82: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/82.jpg)
What is the maximum buffer zone credit for metam sodium and metam
potassium?
1 2 3
0% 0%0%
1. 20%2. 40%3. 80%
![Page 83: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/83.jpg)
Besides fumigant handlers, who else may enter the buffer zone?
1 2 3
0% 0%0%
1. Vehicular and bicycle traffic on roadways.
2. No one; only fumigant handlers may enter.
3. People passing through on a sidewalk or walking path
![Page 84: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/84.jpg)
In what way is posting of fumigant treated areas (the application block) different from the Worker Protection Standard (WPS) no-
entry posting of nonfumigated treated areas?
1 2 3
0% 0%0%
1. The location of the warning sign.
2. The information on the warning sign.
3. The length of time the warning sign remains posted.
![Page 85: Module Three Chapters 7, 8, & 9](https://reader035.fdocuments.net/reader035/viewer/2022081507/56816410550346895dd5ba75/html5/thumbnails/85.jpg)
Two buffer zones can overlap if at least twelve hours have passed between the completion of
the first and the start of the second.
1 2
0%0%
1. True2. False