TT T T EE E E SS S S TT T T RR R R EE E E PP P P OO O O RR R R TT T T OMEGA POINT LABORATORIES, INC. 16015 Shady Falls Road Elmendorf, TX 78112 (v) 210-635-8100 (f) 210-635-8101 800-966-5253 www.opl.com MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No. 16723-113972 April 22, 2003 Prepared for: John W. Mallette Sr.. 311 Flannan Rd Ste A-100 Pensacola, Fl 32507-3160

Transcript of MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE...

Page 1: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

TTTTEEEE

SSSSTTTT

RRRREEEE

PPPPOOOO

RRRRTTTT

OMEGA POINTLABORATORIES, INC.16015 Shady Falls Road

Elmendorf, TX 78112(v) 210-635-8100(f) 210-635-8101

800-966-5253www.opl.com

MMMMOOOODDDDIIIIFFFFIIIIEEEEDDDD AAAASSSSTTTTMMMM EEEE 1111333355554444CCCCOOOONNNNEEEE CCCCAAAALLLLOOOORRRRIIIIMMMMEEEETTTTEEEERRRR

TTTTHHHHEEEERRRRMMMMAAAALLLL RRRREEEESSSSPPPPOOOONNNNSSSSEEEE TTTTEEEESSSSTTTT((((FFFFiiiinnnnaaaallll RRRReeeeppppoooorrrrtttt))))

Reflectec Thermal Fabric&

Reflectec Fiberboard

Project No. 16723-113972

April 22, 2003

Prepared for:

John W. Mallette Sr..311 Flannan Rd Ste A-100Pensacola, Fl 32507-3160

Page 2: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

MMMMOOOODDDDIIIIFFFFIIIIEEEEDDDD AAAASSSSTTTTMMMM EEEE 1111333355554444CCCCOOOONNNNEEEE CCCCAAAALLLLOOOORRRRIIIIMMMMEEEETTTTEEEERRRR

TTTTHHHHEEEERRRRMMMMAAAALLLL RRRREEEESSSSPPPPOOOONNNNSSSSEEEE TTTTEEEESSSSTTTT((((FFFFiiiinnnnaaaallll RRRReeeeppppoooorrrrtttt))))

Reflectec Thermal Fabric&

Reflectec Fiberboard

Project No. 16723-113972

April 22, 2003

Prepared for:

John W. Mallette Sr..311 Flannan Rd Ste A-100Pensacola, Fl 32507-3160

Page 3: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

OM

EGA POIN

T

LAB

ORATORI

ES

®

Omega Point Laboratories, Inc.16015 Shady Falls Road

Elmendorf, Texas 78112-9784210-635-8100 / FAX: 210-635-8101 / 800-966-5253

www.opl.com / e-mail: [email protected]

AbstractThermal Response testing using the Cone Calorimeter (ASTM E 1354) was performed onspecimens submitted by John W. Mallette Sr. The Reflectec Thermal Fabric specimens wereapproximately 4.5 inches square, 1/4 inch thick and the Reflectec Fiberboard wasapoproximately 6 inch square and 1/8 inch thick. The testing procedure was according to anagreement with John W. Mallette Co. and Omega Point Laboratories in which the ConeCalorimeter was used to expose the top side of the specimens to radiative heat flux whilemeasuring the temperatures of the top surface, the bottom surface, and 1/2 inch below thespecimen. The results are in terms of bottom side temperatures as a function of top sidesurface temperatures.

This report and the information contained herein is for the exclusive use of the client namedherein. Omega Point Laboratories, Inc. authorizes the client to reproduce this report only i freproduced in its entirety. The description of the test procedure, as well as the observations andresults obtained, contained herein are true and accurate within the limits of sound engineeringpractice. These results apply only for the specimens tested, in the manner tested, and may notrepresent the performance of other specimens from the same or other production lots nor of theperformance when used in combination with other materials. The test specimen identification isas provided by the client and Omega Point Laboratories, Inc. accepts no responsibility for anyinaccuracies therein. Omega Point did not select the specimen and has not verified thecomposition, manufacturing techniques or quality assurance procedures. This report does notimply certification of the product by Omega Point Laboratories, Inc. Any use of the Omega PointLaboratories name, any abbreviation thereof or any logo, mark, or symbol therefor, for ad-vertising material must be approved in writing in advance by Omega Point Laboratories, Inc. Theclient must have entered into and be actively participating in a Listing & Follow-up Serviceprogram. Products must bear labels with the Omega Point Laboratories Certification Mark todemonstrate acceptance by Omega Point Laboratories, Inc. into the Listing program.

Date: April 22, 2003 Javier O. TrevinoManager, Special Projects

Reviewed and approved:

William E. Fitch, P.E. No. 55296 Date: April 22, 2003 Executive Vice President

Page 4: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John Mallette Sr. Page iii

LA

BORATOR

IES

OM

EGA POIN

T

TABLE OF CONTENTS

ITEM PAGE

Introduction 1

Test Procedure 1

Test Specimen Description 2

Test Results and Observations 2

Appendices

Appendix A: Thermocouple Data 5

Appendix B: Photographs 9

Last Page of Report 11

Page 5: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John Mallette Sr. Pg 1

INTRODUCTION

The tests described herein were conducted in accordance with a modified versionof ASTM E1354 Standard Test Method. The test method for this series of tests isbased on the observation that radiant heat applied to a surface will provide atemperature increase on that surface.

The testing procedure was according to an agreement with John W. Mallette Sr.,and Omega Point Laboratories in which the Cone Calorimeter was used to exposethe top side of the specimens to radiative heat flux while measuring thetemperatures of the top surface, the bottom surface, and 1/2 inch below thespecimen. The results are in terms of bottom side temperatures as a function oftop side surface temperatures.

TEST PROCEDURE

To assist the reader in understanding the test apparatus and procedures, Figure1, at the end of the text of this report, contains a schematic drawing of the conecalorimeter apparatus.

In this test method, an electrically heated radiant energy source in the shape of atruncated cone is positioned 75 mm (3 in.) from the surface of the specimen andproduces an irradiance level over surface area of the specimen. The specimen ispositioned horizontally. The specimen is mounted using a customized specimenholder that allowed air to move freely above and below the specimen. The framereduces the effective exposed surface area of the specimen to approximately 16square inches (4” x 4”).

The temperatures of the top side (hot side)and bottom side (cold side) of thespecimen are measured with 24 ga. type K thermocouples. Generally,thermocouple #1 (TC #1) was placed in contact with the top surface, TC #2 wasplaced 1/2” below the specimen surface (at the request of the client) and TC #3 wasplaced in contact with the surface of the bottom side of the specimen. Thetemperatures were recorded using a computerized data acquisition system as afunction of time.

Page 6: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John Mallette Sr. Pg 2

DESCRIPTION AND PREPARATION OF TEST SPECIMENS

The test specimens arrived with the client the morning of April 8, 2003.

Specimens submitted by: John Mallette Sr.

Date received: April 8, 2003

Date(s) tested: April 8, 2003

Type of material: Reflectec Thermal Fabric and Reflectec Fiberboard

Identification number(s): N/A

Description and size: Test #1 and #2: Reflectec Thermal Fabric: Multi-layeredfabric w/ Nomex outer layer on both sides. Approx 1/4” thick. Test #3:Reflectec Fiberboard: Fiberboard w/ aluminum foil facer on both sides.Approx. 1/8” thick.

Specimen preparation and mounting method: Test #1: Reflectec Thermal Fabric(Dry) mounted such that 4” x 4” was exposed to the radiant flux of heat. Test#2: Reflectec Thermal Fabric (Moist on Cold Side) mounted such that 4” x 4”was exposed to the radiant flux of heat. Test #3: Reflectec Fiberboard (Dry)mounted such that 4” x 4” was exposed to the radiant flux of heat.

TEST RESULTS

Results from these tests are presented in the following formats:

Individual Test Data Plots (Appendix A)

Summary Tables (Next Page)

Photographs (Appendix B).

Page 7: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John Mallette Sr. Pg 3

TABLE 1: Reflectec Thermal Fabric Results:Topside Surface Temperature Approx 200 deg C

SpecimenName

Temp TopsideSurface (deg C)

Temp 1/2” Below(deg C)

Temp UndersideSurface (deg C)

Reflectec ThermalFabric(Dry)

97.8 23.9 N/A

Reflectec ThermalFabric(moist underside)

98.7 24.7 43.7

N/A = During this test, the temperature of the underside surface was not measured.

TABLE 2: Reflectec Thermal Fabric Results:Topside Surface Temperature at end of Test

SpecimenName

Temp TopsideSurface (deg C)

Temp 1/2” Below(deg C)

Temp UndersideSurface (deg C)

Reflectec ThermalFabric(Dry)

236.5 29.2 N/A

Reflectec ThermalFabric(moist underside)

222.9 31.3 76.3

N/A = During this test, the temperature of the underside surface was not measured.

TABLE 3: Reflectec Fiberboard ResultsResults at approx 200 deg C & at end of tesr

SpecimenName

Temp TopsideSurface (deg C)

Temp 1/2” Below(deg C)

Temp UndersideSurface (deg C)

ReflectecFiberboard(Dry)

97.5 25.4 54.1

ReflectecFiberboard(Dry)

296 37.6 139

Page 8: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John Mallette Sr. Pg 4

Cone Heater

Test Specimen

Load Cell

Spark Igniter

Gas Sampling Ring

Orifice Plate

Exhaust Duct

Exhaust Blower

Cold Trap

Dessicant

CO2 Removal

To O2 Analyzer

To CO, CO2 Analyzers

Particulate Filter

Laser Smoke Meter

Exhaust Hood

Figure 1. Schematic Drawing of the Cone Calorimeter (ASTM E1354)

Page 9: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John Mallette Sr. Pg 5

Appendix A

Thermocouple Data Plots

Page 10: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Test #1 Reflectec Thermal Fabric (Dry)TC #1 Hot Side Touching Fabric

TC #2 Cold Side 1/2" Below Fabric

01 02 03 04 05 06 07 08 09 0

100110120130140150160170180190200210220230240250

0

2.6

5.2

7.8

10

.4 13

15

.6

18

.2

20

.8

23

.4 26

28

.6

31

.2

33

.8

36

.4 39

41

.6

44

.2

46

.8

49

.4 52

54

.6

57

.2

59

.8

62

.4 65

67

.6

70

.2

72

.8

75

.4 78

80

.6

83

.2

Time (min)

Tem

p (

deg

C)

TC #1

TC #2

Page 11: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Test #2 Reflectec Thermal Fabric (Moist on Cold Side)TC #1 Hot Side Touching Fabric

TC #2 Cold Side 1/2" Below FabricTC #3 Cold Side Touching Fabric

01 02 03 04 05 06 07 08 09 0

100110120130140150160170180190200210220230240

0

2.3

6

4.7

2

7.0

8

9.4

3

11

.8

14

.2

16

.5

18

.9

21

.2

23

.6

25

.9

28

.3

30

.7 33

35

.4

37

.7

40

.1

42

.5

44

.8

47

.2

49

.5

51

.9

54

.2

56

.6 59

61

.3

63

.7 66

68

.4

70

.8

73

.1

75

.5

Time (min)

Tem

p (

deg

C)

TC #1

TC #2

TC #3

Page 12: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Test #3 Reflectec FiberboardTC #1 Hot Side Touching Foil Facer

TC #2 Cold Side 1/2" From Foil FacerTC #3 Cold Side Touching Foil Facer

01 02 03 04 05 06 07 08 09 0

100110120130140150160170180190200210220230240250260270280290300310320

0

1.4

3

2.8

5

4.2

8

5.7

7.1

3

8.5

5

9.9

8

11

.4

12

.8

14

.3

15

.7

17

.1

18

.5 20

21

.4

22

.8

24

.2

25

.7

27

.1

28

.5

29

.9

31

.4

32

.8

34

.2

35

.6

37

.1

38

.5

39

.9

41

.3

42

.8

44

.2

45

.6

Time (min)

Tem

p (

deg

C)

TC #1

TC #2

TC #3

Page 13: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John W. Mallette, Sr. APPENDIX B Pg 9

LA

BORATOR

IES

OM

EGA POIN

T

Appendix B

Photographs

Page 14: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John W. Mallette, Sr. APPENDIX B Pg 10

LA

BORATOR

IES

OM

EGA POIN

T

The Cone Calorimeter w/ Specimen in Place w/ Thermocouples

The Cone Calorimeter Radiant Cone Energized

Page 15: MODIFIED ASTM E 1354 CONE CALORIMETER … · MODIFIED ASTM E 1354 CONE CALORIMETER THERMAL RESPONSE TEST (Final Report) Reflectec Thermal Fabric & Reflectec Fiberboard Project No.

Project No. 16723-113972 April 22, 2003John W. Mallette, Sr. APPENDIX B Pg 11

LA

BORATOR

IES

OM

EGA POIN

T

Test Specimens #1 (Left) and #2 (Right) after test.Left degraded at 236.5 deg C: Right degraded at 222.9 degC

Test Specimen #3 After TestSpecimen Temperature at end of test was 296 deg C