MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL...

18
MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME RATED POWER 200kVA STANDBY RATED POWER 220kVA POWER FACTOR 0.80 PF FUEL USAGE @ 75% 31.0 L/hr Powered by:

Transcript of MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL...

Page 1: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

MODEL : PP 200 SP

GENERATING SET PERFORMANCE 50Hz 60Hz

VOLTAGE V400

PHASES Three

PRIME RATED POWER 200kVA

STANDBY RATED POWER 220kVA

POWER FACTOR 0.80 PF

FUEL USAGE @ 75% 31.0 L/hr

Powered by:

Page 2: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

ENGINE PERKINS 1106A-E70TAG

PERFORMANCE 50Hz 60Hz

BASELOAD RATED POWER TBA

PRIME RATED POWER 173.9KWm

STANDBY RATED POWER 191.3KWm

FUEL CONSUMPTION 206g/KWh @ 100%212g/KWh @ 75%211g/KWh @ 50%

TYPE Diesel 4 stroke

ASPIRATION

INJECTION TYPE Direct injection

ENGINE GOVERNOR Electronic governor

CYLINDERS AND ARRANGEMENT Six in line

BORE AND STROKE 105mm x 135mm

COMPRESSION RATIO 16.1 : 1

ELECTRICAL SYSTEM VOLTAGE 24 volt

BATTERY TYPE Lead acid, 24V

DERATING FOR TEMPERATURE 40 deg C

DERATING FOR ALTITUDE 1000m

DERATING FOR HUMIDITY 90%

Turbocharged aftercooled

Murphy EL150K water levelsensor to constantly monitorthe radiator water level. It willput the generator into shutdown in event of loss ofcoolant regardless of if the unitis running or not.

Powered by a world renownedPerkins Engine backed by aworld wide OEM warranty.

Water jacket heater to keep theengine at optimum temperaturewhilst in standby. Configured tosense water temperature whilststationary and provide an alarmin event of a failure of the heat-er.

ENGINE

Page 3: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

ALTERNATOR STAMFORD

PERFORMANCE 50Hz 60Hz

MODEL UCI274H

BASELOAD RATED POWER 40 deg C 182kVA

PRIME RATED POWER 40 deg C 200kVA

STANDBY RATED POWER 40 deg C 212kVA

STANDBY RATED POWER 27 deg C 220kVA

EFFICIENCY 93%

STANDARD WING CONNECTIONS Star Delta

EXCITER

POLES 4 poles

PHASES Three phases

WIRES 12 leads

VOLTAGE REGULATION +/- 1.0%

INSULATION CLASS Class H

ENCLOSURE IP23

MAXIMUM OVERSPEED 150%

STANDARD AVR MODEL MX341

OPTIONAL AVR MODEL MX321

DERATING FOR TEMPERATURE 40 deg C

DERATING FOR ALTITUDE 1000mm

Separately excited by P.M.G.

Electrical power is generated usingthe well recognised Stamford New-age alternator.

Anti condensation heater to keepthe alternator windings at optimumtemperature whilst the generator isin standby.

Permanent Magnet Generator sep-arate excitation system to offeroptimum load response anddurability to unbalanced or highlyharmonic load types.

ALTERNATOR

Page 4: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

GENERATOR EQUIPMENT

DIMENSIONS AND CAPACITY

STANDARD MODELS

INTEGATED FUEL TANKCAPACITY

WEIGHT

STANDARD OPTIONAL KG LENGTH WIDTH HEIGHT

SUPER SILENT CANOPY TYPE(75dB(A)@ 1 metre)

750 TBA 3250kg 3500mm 1130mm 2010mm

DIMENSIONS

Central lifting hook and forkliftpockets for versatility.

Rust resistant canopiesconstructed from zinc galvanisedsteel sheet, prior to polyesterpowder coating (up to 500kVA).

Ground mounted skid enablesuse in harsh environments. Thegenerator can be dragged overrough ground via the two eyes.

High servicing level with wideopening doors.

Residential exhaust silencinginternal to the canopy. Suitablefor use near residential areaswhere noise could be aproblem.

Super silent noise rating for75dB(A) @ 1 metre or 65dB(A)@ 7 metres from the canopy.Achieved by special attenuatorsinside the canopy and thickerthan usual acoustic lining.

Lockable door hardwareconstructed from rust resistantmaterials.

Large fuel tank for (up to250kVA) 24 hours run time atfull load. The fuel tank isconstructed and pressuretested in accordance withAS1692 and the latest HSNOregulations

DIMENSIONS

Page 5: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

AUTOMATIC MODELS – EQUIPMENT

4 poles ABB circuit breaker, electronic control unit ComAp AMF25-NT control panel box key,emergency stop button, water jacket heater, battery charger, anti condensation heater.

AUTOMATIC MODELS – PROTECTORS

Low oil pressure, low fuel level, overload, over/ under frequency, low voltage, over/ under batteryvoltage, belt breakage.

AUTOMATIC MODELS – INSTRUMENTATION

Voltmeter, ammeter (3 phases), frequency meter, hour meter, battery voltage, fuel level.

Dedicated battery charger withboost and flat modes. Batterycharger is configured to provide analarm in event of a fault with thecharging system.

Wiring and protection inaccordance with AS3000 andAS3010. Robust, clear labellingsystem with comprehensiveschematic drawings.

Option of a high spec controllercapable of synchronising withother generators or the mainssupply. Standard controller canbe used in key start or standardAMF mode.

Battery isolator to enable thebattery to be switched off in theevent of the generator being putinto storage for extendedperiods.

Range of standard NewZealand series 56 single phaseand three phase sockets onunits up to 150kVA. Additionalsockets available on request.

CONTROLLER

Four pole MCCB in accordancewith AS3010. The motorisedMCCB is fitted with a stunt trip toprotect the generator in event ofa sudden shutdown.

Page 6: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME
Page 7: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME
Page 8: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

UCI274H - Technical Data Sheet

Page 9: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

UCI274HSPECIFICATIONS & OPTIONS

STANDARDSNewage Stamford industrial generators meet therequirements of BS EN 60034 and the relevant sectionof other international standards such as BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.

VOLTAGE REGULATORS

SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator(AVR) to the exciter stator. The high efficiencysemiconductors of the AVR ensure positive build-upfrom initial low levels of residual voltage.The exciter rotor output is fed to the main rotor througha three phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.

SX440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor througha three-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The SX440 will support a range of electronicaccessories, including a 'droop' Current Transformer(CT) to permit parallel operation with other acgenerators.If 3-phase sensing is required with the self-excitedsystem, the SX421 AVR must be used.

SX421AVRThis AVR also operates in a self-excited system. Itcombines all the features of the SX440 with,additionally, three-phase rms sensing for improvedregulation and performance. Over voltage protection isprovided via a separate circuit breaker. An engine reliefload acceptance feature is built in as standard.

MX341 AVRThis sophisticated AVR is incorporated into theStamford Permanent Magnet Generator (PMG) controlsystem.The PMG provides power via the AVR to the mainexciter, giving a source of constant excitation powerindependent of generator output. The main exciteroutput is then fed to the main rotor, through a full wavebridge, protected by a surge suppressor. The AVR hasin-built protection against sustained over-excitation,caused by internal or external faults. This de-excites themachine after a minimum of 5 seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.If three-phase sensing is required with the PMG systemthe MX321 AVR must be used.We recommend three-phase sensing for applicationswith greatly unbalanced or highly non-linear loads.

MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phaserms sensing, for improved regulation and performance.Over voltage protection is built-in and short circuitcurrent level adjustments is an optional facility.

WINDINGS & ELECTRICAL PERFORMANCEAll generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimumdesign for trouble-free supply of non-linear loads. The2/3 pitch design avoids excessive neutral currentssometimes seen with higher winding pitches, when inparallel with the mains. A fully connected damperwinding reduces oscillations during paralleling. Thiswinding, with the 2/3 pitch and carefully selected poleand tooth designs, ensures very low waveformdistortion.

TERMINALS & TERMINAL BOXStandard generators are 3-phase reconnectable with 12ends brought out to the terminals, which are mountedon a cover at the non-drive end of the generator. Asheet steel terminal box contains the AVR and providesample space for the customers' wiring and glandarrangements. It has removable panels for easyaccess.

SHAFT & KEYSAll generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with ahalf key.

INSULATION/IMPREGNATIONThe insulation system is class 'H'.All wound components are impregnated with materialsand processes designed specifically to provide the highbuild required for static windings and the highmechanical strength required for rotating components.

QUALITY ASSURANCEGenerators are manufactured using productionprocedures having a quality assurance level to BS ENISO 9001.

The stated voltage regulation may not be maintained inthe presence of certain radio transmitted signals. Anychange in performance will fall within the limits ofCriteria 'B' of EN 61000-6-2:2001. At no time will thesteady-state voltage regulation exceed 2%.

NB Continuous development of our products entitles usto change specification details without notice, thereforethey must not be regarded as binding.

Front cover drawing typical of product range.

2

Page 10: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.

A.V.R. MX321 MX341

VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT

CONTROL SYSTEM SELF EXCITED

A.V.R. SX460 SX440 SX421

VOLTAGE REGULATION ± 1.5 % ± 1.0 % ± 0.5 % With 4% ENGINE GOVERNING

SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT

INSULATION SYSTEM CLASS H

PROTECTION

RATED POWER FACTOR

STATOR WINDING

WINDING PITCH

WINDING LEADS

STATOR WDG. RESISTANCE

ROTOR WDG. RESISTANCE

R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED

BEARING DRIVE END

BEARING NON-DRIVE END

WEIGHT COMP. GENERATORWEIGHT WOUND STATORWEIGHT WOUND ROTORWR² INERTIASHIPPING WEIGHTS in a cratePACKING CRATE SIZE

TELEPHONE INTERFERENCECOOLING AIRVOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138kVA BASE RATING FOR REACTANCE VALUES 200 200 200 n/a 237.5 245 245 255

Xd DIR. AXIS SYNCHRONOUS 2.11 1.91 1.77 - 2.50 2.31 2.11 2.02X'd DIR. AXIS TRANSIENT 0.18 0.16 0.15 - 0.21 0.19 0.18 0.17X''d DIR. AXIS SUBTRANSIENT 0.12 0.11 0.10 - 0.14 0.13 0.12 0.11Xq QUAD. AXIS REACTANCE 1.28 1.15 1.07 - 1.53 1.41 1.29 1.23X''q QUAD. AXIS SUBTRANSIENT 0.17 0.15 0.14 - 0.20 0.18 0.17 0.16XL LEAKAGE REACTANCE 0.08 0.08 0.07 - 0.10 0.09 0.08 0.08X2 NEGATIVE SEQUENCE 0.13 0.12 0.11 - 0.16 0.15 0.13 0.13X0 ZERO SEQUENCE 0.08 0.08 0.07 - 0.10 0.09 0.08 0.08

REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST.T''d SUB-TRANSTIME CONST.T'do O.C. FIELD TIME CONST.Ta ARMATURE TIME CONST.SHORT CIRCUIT RATIO

REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)

BALL. 6310-2RS (ISO)

1/Xd

0.042 s0.012 s1.1 s

0.012 s

1.82 Ohms at 22°C

0.0155 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED

BALL. 6315-2RS (ISO)

227.53 kg1.9349 kgm2

IP23

0.8

DOUBLE LAYER CONCENTRIC

TWO THIRDS

12

641 kg626 kg253 kg

UCI274H

0.514 m³/sec 1090 cfm 0.617 m³/sec 1308 cfm

50 HzTHF<2%

60 HzTIF<50

216.57 kg1.8843 kgm2

WINDING 311

1 BEARING 2 BEARING

2250 Rev/Min

253 kg

673 kg 123 x 67 x 103 (cm)

659 kg 123 x 67 x 103 (cm)

3

Page 11: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

Winding 311UCI274H

THREE PHASE EFFICIENCY CURVES

50Hz

4

Page 12: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

UCI274HWinding 311

Locked Rotor Motor Starting Curve

MX SX

50Hz

60Hz

MX SX

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700 800LOCKED ROTOR kVA

PER

CENT

TRAN

SIENT

VOLT

AGE D

IP

346V 380V 400V 415V 440V

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700LOCKED ROTOR kVA

PER

CENT

TRAN

SIENT

VOLT

AGE D

IP

346V 380V 400V 415V 440V

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700 800 900 1000LOCKED ROTOR kVA

PER

CENT

TRAN

SIENT

VOLT

AGE D

IP

380V 416V 440V 460V 480V

0

5

10

15

20

25

30

0 100 200 300 400 500 600 700 800LOCKED ROTOR kVA

PER

CENT

TRAN

SIENT

VOLT

AGE D

IP

380V 416V 440V 460V 480V

6

Page 13: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

3-phase 2-phase L-L 1-phase L-NVoltage Factor Voltage Factor x 1.00 x 0.87 x 1.30

380v X 1.00 416v X 1.00 x 1.00 x 1.80 x 3.20400v X 1.07 440v X 1.06 x 1.00 x 1.50 x 2.50415v X 1.12 460v X 1.12 10 sec. 5 sec. 2 sec.440v X 1.18 480v X 1.17

The sustained current value is constant irrespectiveof voltage level

Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated SpeedBased on star (wye) connection.

Max. sustained durationAll other times are unchanged

Instantaneous

SustainedMinimum

UCI274H

50Hz 60Hz

Sustained Short Circuit = 1,000 Amps

Sustained Short Circuit = 1,400 AmpsNote 1The following multiplication factors should beused to adjust the values from curve betweentime 0.001 seconds and the minimum currentpoint in respect of nominal operating voltage :

Note 2The following multiplication factor should be used to convert thevalues calculated in accordance with NOTE 1 to those applicableto the various types of short circuit :

Note 3Curves are drawn for Star (Wye) connected machines. For otherconnection the following multipliers should be applied to currentvalues as shown : Parallel Star = Curve current value X 2Series Delta = Curve current value X 1.732

50Hz

60Hz

10

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CUR

RENT

(Am

ps)

SYMMETRICAL

ASYMMETRICAL

10

100

1000

10000

0.001 0.01 0.1 1 10TIME (secs)

CUR

RENT

(Am

ps)

SYMMETRICAL

ASYMMETRICAL

7

Page 14: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

Class - Temp Rise

Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440

Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220

Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254

kVA 182.0 182.0 182.0 n/a 200.0 200.0 200.0 n/a 212.0 212.0 212.0 n/a 220.0 220.0 220.0 n/a

kW 145.6 145.6 145.6 n/a 160.0 160.0 160.0 n/a 169.6 169.6 169.6 n/a 176.0 176.0 176.0 n/a

Efficiency (%) 93.3 93.5 93.6 n/a 93.0 93.3 93.4 n/a 92.8 93.1 93.3 n/a 92.7 93.0 93.2 n/a

kW Input 156.1 155.7 155.6 n/a 172.0 171.5 171.3 n/a 182.8 182.2 181.8 n/a 189.9 189.2 188.8 n/a

Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480

Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240

Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277

kVA 218.8 225.0 225.0 235.0 237.5 245.0 245.0 255.0 250.0 258.8 258.8 275.0 256.3 265.0 265.0 280.0

kW 175.0 180.0 180.0 188.0 190.0 196.0 196.0 204.0 200.0 207.0 207.0 220.0 205.0 212.0 212.0 224.0

Efficiency (%) 93.2 93.4 93.6 93.7 93.0 93.2 93.5 93.6 92.8 93.1 93.3 93.4 92.7 93.0 93.3 93.3

kW Input 187.8 192.7 192.3 200.6 204.3 210.3 209.6 217.9 215.5 222.4 221.9 235.5 221.2 228.0 227.2 240.1

UCI274HWinding 311 / 0.8 Power Factor

RATINGS

TD_UCI274H.GB_11.02_02_GB

Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C

DIMENSIONS

�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

����������������������������������������������������������������������������������������������������������

��������������������������������������������������������������������������������������������������������������

��������������������������������������������������������������������������������������������������������������

������������������������������������������������������������������������������������������������������������

�������������������������������������������������������

��������������������������������������������������������������������������������������������������������������

PO Box 17 • Barnack Road • Stamford • Lincolnshire • PE9 2NBTel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100Website: www.newage-avkseg.com

© 2002 Newage International Limited.Reprinted with permission of N.I. only.Printed in England.

50Hz

60Hz

Page 15: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

New InteliLiteNT

SINGLE SET GEN-SET CONTROLLER

CREATIVE ENGINEERING

ComAp is a member of AMPS(The Association of Manufacturers of Power generating Systems).

ComAp products meet the highest standards, with every stage of production undertaken in accordance with the ISO certification obtained in 1998.

Description

InteliLiteNT models are the new integrated controllers for gen-sets operating in single standby mode. Based on the field proven InteliLite architecture, the new controllers fulfill every requirement needed for AMF and MRS applications – including modem and Internet control, user configuration and complete gen-set monitoring and protection.

InteliLiteNT controllers are easy to use and feature an intuitive user interface with graphic display. The built-in event and performance log with backed-up real time clock makes troubleshooting even simpler.

The new design brings seamless integration with the latest breed of EFI diesel engines from all major manufacturers. This offers a higher level of functionality with users able to display a full range of values from the EFI engine on standard analog gauges and true RMS measurement of electric values.

Benefits

Less wiring and componentsLess engineering and programmingHistory log – easy troubleshooting and warranty claim handlingRemote monitoring reduced call-out costs of service engineersAnalog gauge (VDO, Datcon, …) outputs – operator friendlyPerfect price/performance ratio

Page 16: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

Features

3 phase AMF function* Over/Under frequencyOver/Under voltageVoltage asymmetry

3 phase generator protectionsOver/Under frequencyOver/Under voltageCurrent/Voltage asymmetryOvercurrent/Overload

True RMS Voltage measurement3 phase generator and mains* voltagesVoltage range 277 V p-n, 480 V p-p Maximal measured voltage 300 V p-nPT ratio range 0.1–500

True RMS current measurements3 generator phase currentsCurrent range 5 AMaximal measured current 10 ACT ratio range 1–5000

Power measurementsAct / React Power and Power Factor per phaseActive and Reactive Energy counter

•••

••••

••••

••••

InteliLiteNT

Event and performance log + RTCEvent based history with 119 events* Reason, Data and Time + all important values are storedBattery backed-up RTCTest Run scheduler

User interfaceGraphic 128 × 64 pixels displayMultiple language capabilitySetpoints adjustable via keyboard or PCButtons with mechanical feedback

Inputs and outputs3 configurable analog inputs6 or 7* Binary inputs6 or 7* Binary outputsMagnetic pick-up inputD+ preexcitation terminal Optional 8 analog gauge drive outputs, compatible with VDO, Datcon gauges

EFI engine supportCummins MODBUSEngine specific J1939 for all major manufacturersDiagnostic messages in plain text

Communication interfaces

••

••••

••••••

••

Optional USB and RS232 plug-in modulesMODBUS RTU (requires RS232 module)Internet

Mechanical and operation parametersUnit dimension 120 × 180 mmSealed front face rated for IP65Hard plexiglass LCD coverOperation temperature -20°C – +70°C standard version -40°C – +70°C low temperature versionPower supply voltage 8–36 VVoltage drops shorter than 50 ms do not affect operation

Extension modules

IL-NT RS232 RS232 plug-in interfaceIL-NT USB USB plug-in interfaceIL-NT AOUT8 gauge plug-in interfaceIL-NT RD remote display IG-IB Internet moduleIGS-PTM** extension I/O moduleIGS-IOM** extension I/O moduleIGL-RA15** 15 LED remote annunciator

* Only for Models AMF 20 and AMF 25

** Only for Models MRS 15, MRS 16 and AMF 25

•••

••••

••

IG-IB

PC MODEM

+24V

IL-NT RDor

or

STOP

ALARM

or

GENERATOR

DIESEL/GAS ENGINE

1

ENGINE ANALOG

INPUTS

IL-NT

POWER SUPPLY

8 to 36 VDC+ -

BINARY INPUTS

6x MRS xx

7x AMF xx

BINARY OUTPUTS

(OPEN COLLECTOR)

4x MRS xx

5x AMF xx

RS 232INTERFACE

PLUG IN MODULE

BINARYOUTPUTS

(OPENCOLLECTOR)

D+

Oil Pressure

RPM

J1939

1

1 ECU

Start/Stop - Speed Request

Values + Fault Codes

Aux Alternator

Preexcitation

Fuel Solenoid

Starter

2

GENERATOR

CURRENTVO

LTAGE

MEASUREM

ENT

3

8 GAUGE DRIVERS

PLUG IN MODULE

IGL-RA15

IGS-PTM

IG-IOM

or

CAN - J1939

I/O EXTENSION

1

°C

LOAD

3ph

3phG

ENERATOR C.B. CO

NTROL

MAINS C.B. CO

NTROL

3ph

MAINS

MAINS

VOLTAG

EM

EASUREMENT

2

3

2

1 only on Models MRS15, MRS 16 and AMF 25

only on Models AMF 20 and AMF 25

not on Models MRS 10 and MRS 15

Page 17: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

MRS 10MANUAL AND REMOTE START CONTROLLER

3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs6 binary outputs

Available models

MRS 16MANUAL AND REMOTE START CONTROLLER WITH SUPPORT FOR EFI ENGINES

3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs6 binary outputsGCB controlCAN with J1939 supportextension modules capabilityevent and performance log

AMF 20AUTOMATIC MAINS FAILURE START CONTROLLER

3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 7 binary inputs7 binary outputsGCB and MCB control

AMF 25AUTOMATIC MAINS FAILURE START CONTROLLER WITH SUPPORT FOR EFI ENGINE

3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 7 binary inputs7 binary outputsGCB and MCB controlCAN with J1939 supportextension modules capabilityevent and performance log

MRS 15MANUAL AND REMOTE START CONTROLLER WITH SUPPORT FOR EFI ENGINES

3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs6 binary outputsCAN with J1939 supportextension modules capabilityevent and performance log

MRS 11MANUAL AND REMOTE START CONTROLLER

3 configurable analog inputs magnetic pickup input D+ preexcitation terminal 6 binary inputs6 binary outputsGCB control

Page 18: MODEL : PP 200 SP - PowerGenpowergen.co.nz/site/assets/files/1026/pp200sp-_spec_sheet.pdf · MODEL : PP 200 SP GENERATING SET PERFORMANCE 50Hz 60Hz VOLTAGE V400 PHASES Three PRIME

Features and specification are subject to change without prior notice 2007-09

ComAp, spol. s r. o.Czech RepublicPhone: + 420 246 012 111 Fax: + 420 266 316 647E-mail: [email protected]: www.comap.cz

MANUFACTURER: LOCAL DISTRIBUTOR / PARTNER:

www.comap.czFor more information about our products and solutions visit our web-page

FUNCTIONS/CONTROLLERS IL-NT MRS 10 IL-NT MRS 15 IL-NT MRS 11 IL-NT MRS 16 IL-NT AMF 20 IL-NT AMF 25

Binary inputs/outputs 6 / 6 6 / 6 6 / 6 6 / 6 7 / 7 7 / 7

Analog inputs 3 3 3 3 3 3

Magnetic pick-up l l l l l l

AMF function – – – – l l

Input configuration l l l l l l

Output configuration l l l l l l

Voltage measurement Gen. / Mains 3 ph / – 3 ph / – 3 ph / – 3 ph / – 3 ph / 3 ph 3 ph / 3 ph

Current measurement 3 ph3 ph,

IDMT overcurrent3 ph

3 ph, IDMT overcurrent

3 ph3 ph,

IDMT overcurrent

kW/kWh measurement l / – l / l l / – l / l l / – l / l

History file – l – l – l

RTC with battery l l l l l l

GCB/MCB control with feedback –1)/ – –1)/ – l2)/ – l2)/ – l / l l / l

Battery charging alternator circuit l l l l l l

J1939 interface – l – l – l

Internet support with IG-IB with IG-IB with IG-IB with IG-IB with IG-IB with IG-IB

Extension modules –IGL-RA15, IG-IOM,

IGS-PTM–

IGL-RA15, IG-IOM, IGS-PTM

–IGL-RA15, IG-IOM,

IGS-PTM

8 analog gauge drivers O O O O O O

RS232 interface O O O O O O

Modem interface O O O O O O

MODBUS interface O O O O O O

Remote display O O O O O O

Cummins MODBUS O O O O O O

Key: l included – excluded O optional – plug-in module required 1) Automatic GCB control without feedback 2) Manual/Automatic GCB control, but without feedback

Legend: IG-IOM/IGS-PTM: I/O extension modules IGL-RA15: Remote annunciator GCB: Generator circuit breaker MCB: Mains circuit breaker

The Chart of Functions of InteliLiteNT Controllers