Model#: ASC - 36 NG ASC - 36 NG - IPI ASC - 36 LP ASC - 36 ... Model#: ASC - 36 NG ASC - 36 NG

download Model#: ASC - 36 NG ASC - 36 NG - IPI ASC - 36 LP ASC - 36 ... Model#: ASC - 36 NG ASC - 36 NG

of 31

  • date post

    11-Apr-2019
  • Category

    Documents

  • view

    244
  • download

    2

Embed Size (px)

Transcript of Model#: ASC - 36 NG ASC - 36 NG - IPI ASC - 36 LP ASC - 36 ... Model#: ASC - 36 NG ASC - 36 NG

Model#: ASC - 36 NG ASC - 36 NG - IPI ASC - 36 LP ASC - 36 LP - IPI Direct Vent Gas/Heat Recirculating Fireplace

Installer: Leave this manual with the appliance.

Consumer: Retain this manual for future reference.

INSTALLATION AND OPERATING INSTRUCTIONS

Alpine Fireplaces

782 West State Street

Lehi, Utah 84043

(801)768-8411

3/2014

Tested by:

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not

prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other

gases, unless a certified kit is used.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electr ical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be per formed by a qualified installer , service agency or the gas supplier .

Warning: If the information in these instructions is not followed exactly, a fire or explosion may result causing property dam-

age, personal injury or loss of life.

www.alpinefireplaces.com

2 Alpine Supply Company 36 Direct Vent Gas Fireplace

TABLE OF CONTENTS

OPERATING INSTRUCTIONS

Millivolt Instruction Plate................. 22

IPI Instruction Plate...23

Lighting Instructions Millivolt ......... 24

Lighting Instructions IPI................... 24

Shutdown Procedure ......................... 24

FIREPLACE MAINTENANCE

Maintenance Instructions ............... 25

Cleaning Brass Trims ....................... 25

Cleaning the Glass ............................ 26

Cleaning the Logs ............................. 26

SERVICE

Log Replacement .............................. 26

Inspecting the Pilot ........................... 26

Replacement Parts List ..................... 27

TROUBLESHOOTING GUIDE

Millivolt Control .............................. 28

IPI Control.29

Warranty Information30

SAFETY INFORMATION

Safety Label IPI...3

Safety Label Millivolt..4

Before Starting .................................... 5

General Safety Information ................ 5

System Specifications ......................... 6

Derating the Appliance ....................... 6

INSTALLATION REQUIREMENTS

Locating the Fireplace ........................ 6

Gas Line Installation ........................... 7

Clearances ........................................... 7

Mantel Clearances .............................. 7

Hearth Materials ................................. 7

Framing and Finishing ........................ 8

VENTING

Venting Planning ................................ 9

Venting Components List ................... 9

Vent Termination Locations ............. 10

Flex Venting Horizontal ................... 11

Horizontal / Vertical Terminations12

Horizontal Venting Installation ........ 13

Vertical Venting Installation ............. 14

ELECTRICAL SYSTEM

Electrical System Installation ........... 15

Millivolt System Schematic..16

IPI System Schematic...16

INSTALLATION INSTRUCTIONS

Securing the Fireplace ...................... 16

Installing the Venting ....................... 16

Primary Air Adjustment ................... 19

Log Installation ................................. 20

Glass Removal / Installation ............. 21

Remote Control (Optional) ............... 21

Wall Thermostat (Optional) .............. 21

3 Alpine Supply Company 36 Direct Vent Gas Fireplace

Lis

ted

:

DIR

EC

T V

EN

T G

AS

FIR

EP

LA

CE

HE

AT

ER

Tes

ted

to

:

AN

SI

Z2

1.8

8a

.20

12

./C

SA

2.3

3a

-20

12

V

EN

TE

D G

AS

FIR

EP

LA

CE

HE

AT

ER

.

Rep

ort

No

. 3

03

154

9 2

/02

DO

NO

T R

EM

OV

E T

HIS

LA

-

Ser

ial

Nu

mb

er:

AS

C 3

6-I

PI PR

OP

AN

E :

Ser

ies

AS

C3

6-L

P-I

PI

Min

imu

m s

upp

ly p

ress

ure

1

1

W

C

Man

ifold

pre

ssu

re h

igh

10.0

W

C

Man

ifold

pre

ssu

re l

ow

6

.4

WC

O

rifi

ce S

ize

#

55

DM

S

Min

imu

m i

nput

1

7,0

00

BT

U/

h

Max

imu

m i

npu

t

21,0

00

BT

U/

h

Alt

itud

e

2

500

6

500

Ft

NA

TU

RA

L G

AS

: S

erie

s A

SC

36

-NG

-

IPI

Min

imu

m s

upp

ly p

ress

ure

5

WC

Man

ifold

pre

ssu

re h

igh

3

.5

W

C

Man

ifold

pre

ssu

re l

ow

1

.6

WC

Ori

fice

Siz

e

# 4

6

DM

S

Min

imu

m i

nput

1

1,6

00

BT

U/h

M

axim

um

in

pu

t

21,9

00

BT

U/h

Alt

itud

e

2

500

6

500

Ft

Model ASC36-LP-IPI

Model ASC36-NG-IPI

Use

On

ly M

& G

Dir

ectV

ent

Pro

Syst

em .

Use

on

ly D

irec

tVen

t P

ro 4

6D

VA

-VC

H c

ap o

n v

erti

cal

app

lica

tion

s.

This

ap

pli

ance

must

b

e

inst

all

ed in

ac

cord

ance

wit

h t

he

man

ufa

ctu

rer

s i

nst

alla

tion i

nst

ruct

ion

s an

d w

ith

loca

l co

des

, if

an

y;

if n

ot,

foll

ow

th

e cu

rren

t A

NS

I Z

22

3.1

in

the

US

A.

Th

is v

ente

d g

as f

irep

lace

hea

ter

is n

ot

for

use

wit

h a

ir f

ilte

rs.

# 4

32

-917

Fan

Kit

may

be

use

d. E

lect

rica

l su

pp

ly 1

20

VA

C,

.62

Am

ps,

60

Hz.

VE

NT

ED

GA

S F

IRE

PL

AC

E H

EA

TE

R N

OT

FO

R U

SE

WIT

H S

OL

ID F

UE

L.

Alp

ine

Gas

Fir

ep

lace

s

Leh

i, U

tah

M

ade

in U

SA

Fie

ld C

on

ver

ted

Put

Lab

el

Her

e

Th

is

ap

pli

an

ce

mu

st

be

inst

all

ed

in

acc

ord

an

ce w

ith

th

e fo

llow

ing m

inim

um

clea

ran

ces:

1 1

/2

to c

om

bu

stib

les

T

op

1/2

to

co

mb

ust

ible

s S

ides

1/2

to

co

mb

ust

ible

s B

ack

0

to c

om

bu

stib

les

B

ott

om

18

T

op