Model 8720 - Hawsco

26
HAWS ® P/N 0580001082 Rev.1 9/20 Model 8720 Page 1 of 26 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: [email protected] Website: www.hawsco.com No. 0580001082(1) Model 8720 Outdoor Overhead Tank Shower and Eyewash System Area Classification - Ordinary INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Transcript of Model 8720 - Hawsco

Page 1: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 1 of 26

1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: [email protected] Website: www.hawsco.com

No. 0580001082(1)

Model 8720

Outdoor Overhead Tank Shower and Eyewash System

Area Classification - Ordinary

INSTALLATION, OPERATION &

MAINTENANCE INSTRUCTIONS

Page 2: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 2 of 26

DISCLAIMER

IMPORTANT Read this installation manual completely to ensure proper installation, then file it with the owner or

maintenance department. Compliance and conformity to drain requirements and other local codes and

ordinances is the responsibility of the installer.

Separate parts from packaging and make sure all parts are accounted for before discarding any

packaging material. If any parts are missing, do not begin installation until you obtain the missing parts.

Flush the water supply lines before beginning installation and after installation is complete. Test the unit

for leaks and adequate water flow. Please refer to the enclosed instructions for flushing the unit prior to

use.

The ANSI Z358.1 standard requires an uninterrupted supply of flushing fluid. Flushing fluid should be

tepid per ANSI Z358.1.

The inspection and testing results of this equipment should be recorded weekly to verify proper

operation. This equipment should be inspected annually to ensure compliance with ANSI Z358.1.

Installation and maintenance of this system must be completed by a qualified plumber and electrician in

accordance to the information contained in this installation manual and in compliance with all national

and local codes. When making electrical connections be sure to follow all lockout-tag out safety

procedures.

It is recommended that all water supply and electrical connections be made at temperatures above

freezing (32ºF (0ºC)). Failure to do so may result in major product and or property damage.

For technical support, contact: Haws Services | (800) 766-5612 | www.hawsco.com/services

Page 3: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 3 of 26

TABLE OF CONTENTS DISCLAIMER ................................................................................................................................................ 2

DESCRIPTION OF PRODUCT ..................................................................................................................... 4

SHIPPING, HANDLING AND STORAGE .................................................................................................... 5

INSTALLATION PROCEDURE .................................................................................................................... 6

Checklist for start-up .............................................................................................................................. 9

LOGIC DIAGRAM AND NARRATIVE ........................................................................................................ 10

Tank Control .......................................................................................................................................... 11

Alarm Modes .......................................................................................................................................... 11

Messages................................................................................................................................................ 12

Real Time Clock (RTC) .......................................................................................................................... 12

Fault History ........................................................................................................................................... 12

In Use Alarms ......................................................................................................................................... 13

Fault Condition Notification ................................................................................................................. 13

Maintenance Required Notification ..................................................................................................... 13

Space Heater .......................................................................................................................................... 14

Tank Monitor .......................................................................................................................................... 14

Tank History ........................................................................................................................................... 14

Setting Current Time and Date on the Controller .............................................................................. 14

PREVENTIVE MAINTENANCE .................................................................................................................. 15

Weekly .................................................................................................................................................... 15

Monthly ................................................................................................................................................... 15

Quarterly ................................................................................................................................................. 15

Annually.................................................................................................................................................. 16

MAINTENANCE, TESTING, REPAIR ........................................................................................................ 17

Booth ................................................................................................................................................... 17

Double Swinging Doors .................................................................................................................... 17

Combination Shower/Eyewash ........................................................................................................ 17

Freeze and Scald Valve ..................................................................................................................... 17

TROUBLESHOOTING ................................................................................................................................ 18

SPARE PARTS ........................................................................................................................................... 19

DRAWINGS ................................................................................................................................................ 20

General Arrangement Drawing (0580001082.D-GA) ........................................................................... 20

Electrical Schematic (0580001082.D-EL)............................................................................................. 22

Piping and Instrumentation Diagram (0580001082.D-PID) ................................................................ 24

LIMITED WARRANTY ................................................................................................................................ 26

Page 4: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 4 of 26

DESCRIPTION OF PRODUCT

Haws Corporation Model 8720 overhead tank shower is a foam-insulated, aluminum skinned structure with

high visibility green chemical and UV resistant polyester-based powder coating. Large graphics identify the

building as an emergency shower/eyewash station and assist in guiding the user to the double swing doors.

The interior is illuminated green during standby and changes to white light when someone enters the doors,

or the shower or eyewash is activated. Optional space heating is available for user safety and comfort and

equipment protection.

Tepid water, generated via an immersion heater, is stored in the water tank. The tank temperature is

maintained at 85ºF ± 2ºF (29ºC ± 1ºC). The system is designed to flow a maximum of 30gpm for 15 minutes.

Flow is maintained at a minimum flowrate of 20gpm for the shower and 3gpm for the eye/face wash through

a specially designed redundant siphon system.

The 8720 booth includes a Haws® combination shower and eyewash that is protected with a scald valve.

Optional alarms are activated by proximity switches when the shower and/or eyewash are in use. Dry

contacts can be provided for remote alarm notification and/or both visual and audible alarms with a silencing

circuit that auto resets can be provided.

Page 5: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 5 of 26

SHIPPING, HANDLING AND STORAGE

Performance Series Model

Description Dimensions

W x L x H Weight

Dimensions W x L x H (Crated)

Weight (Crated)

8720 Tank 60” x 60” x 78 1/2” 1360 lbs. 66” x 65” x 85” 1560 lbs.

Shower Enclosure 66” x 79 ½” x 100 ½” 1240 lbs. 72” x 85” x 106” 1440 lbs.

Recommended Equipment, Materials and Supplies to be provided by Installer:

• Existing slab on grade. The installer shall verify that the following minimum requirements of the

existing slab-on-grade are satisfied.

o Allowable Soil Bearing Pressure: 1500 psf

o Slab-on-grade minimum thickness: 6 inches

o Compressive Strength of slab, f’c: 3000 psi

o Adequate footprint area (minimum 6’ x 6’ recommended)

o Adequate vertical space (minimum 20 ft. recommended, 15 ft. required)

• Recommended anchors (Not Included, customer to determine anchor suitability):

High strength adhesive anchors (ICC-ES Report ESR-3187): Hilti HIT-HY 200 Safe Set epoxy

adhesive anchorage system with Hilti hollow drill bit system with Hilti HIT-Z Rod and ASTM A563

Grade A nuts. Frame Feet mounting holes are 17/32” diameter. Each Frame Foot has four (4)

17/32” diameter clearance holes (16 total anchors).

• A forklift capable of lifting 2,000 lbs. should be utilized to transport the unit from truck to site and to

lift tank into position.

Tools and Supplies

• Impact drill/driver with 5/16” nut driver (For Optional Eye/Face Wash Option).

• Steel Strap Shears

• Torque wrench with 7/8” and 9/16” sockets.

• 7/8” and 9/16” box end wrenches.

• Plumbing supply materials including potable water-safe thread sealant for PVC.

(Automatic refill water connection is 1-1/4” NPT male pipe fitting.)

• Appropriate personal protective equipment including safety glasses and work gloves.

Storage

The unit should be stored in a clean, dry place until ready for installation unless otherwise specified.

Page 6: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 6 of 26

INSTALLATION PROCEDURE

a. Remove unit from crate.

b. The unit should be secured on a level site, using the supplied brackets and suitable anchoring

devices.

c. If the booth is to be placed over a drain, the drain should be able to handle a flow of 35 GPM;

otherwise, the slab should be made to allow the water to drain out the sides and away from the

booth (see Figure 1). The unit discharges hundreds of gallons of water, which can cause significant

property damage if not drained properly.

WARNING: Drainage means shall not create an obstruction or tripping hazard.

Figure 1. Example of Slab with Drain Trough

WARNING: Failure to allow water to drain may result in premature failure of booth and void of

product warranty.

d. Attach tank to booth using the supplied hardware. Connect the electrical connections between the

booth and the tank.

e. The connection provided for the water supply is a 1-1/2” NPT union. The system includes a 30gpm

flow control in the water supply line to prevent the unit from being filled too quickly. The water fill

Page 7: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 7 of 26

line should run for a few minutes to eliminate any debris before it enters the equipment. Stop filling

system when low water indicator light turns off or water begins to drain out of tank overflow.

f. Connect electrical supply to the Power Distribution Block. It is recommended that a Disconnect

Switch (see Figure 2) is used to safely interrupt the supply for routine maintenance work.

Disconnect switches are available as an option from Haws.

NOTICE: All Power Connections must be made according to local codes and standards using

components which are compliant with the area the unit is being installed in.

Figure 2. Disconnect Switch Junction Box

CAUTION: Do not apply power to the unit until all water connections are made and the tank and

piping are full of water. Applying power prematurely will damage the equipment.

g. Once all water and power connections are made, open an emergency shower or eyewash valve

(Figure 3) to eliminate any air that may be in the lines, and allow water in the system to flow.

Inspect plumbing for leaks and repair as necessary. During transit, some plumbing may have

become loose, allowing water to leak from the threads. Once the plumbing has been checked, the

shower should run for several minutes to evacuate any debris that might have entered the system.

Turn shower off once water is clear of debris.

Page 8: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 8 of 26

Figure 3. Eyewash

h. Replace any water lost during the previous step and disconnect fill line.

i. At this point the power can be turned on. Heating can take up to 14 hours, depending on supply

water temperature and ambient conditions.

CAUTION: Before turning on the power, close all electrical boxes.

j. The internal space heater has an adjustable thermostat, which is factory set at 70°F (21°C).

WARNING: System is not freeze protected without an energized electrical connection. It is

recommended that installation be completed when ambient temperature is above freezing.

Page 9: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 9 of 26

Checklist for start-up

CHECK LIST FOR START-UP Complete

OK Inspector

Initials

Pre-connection Check

Check all components for any connections or connectors that may have loosened

during shipping.

System Flush (All Electrical Power off for System Flush)

Drain is attached and able to handle a flow of 35 GPM.

System water supply is connected, and all water supply valves opened.

Water is clear and free of any contamination, particles or discoloration.

Connections

System is filled with water.

Connect remote monitoring via plant control system (if applicable).

Applying Power to the System

Verify that the proper voltage is present.

Verify that equipment ground is properly connected.

Apply power to the system.

Verify that the space heater thermostat is set to 70º F (21ºC). Increase the thermostat

set point and verify that the heater is producing. Return the thermostat to 70ºF.

The tank heater set point is preset in the program. It may take 4 to 6 hours for the tank

to reach the operating temperature. Once the tank has reached operating temperature

for a minimum of 1 hour, press the “↑” arrow and record these values in the chart

provided in the Tank Monitor section of the program narrative included in this manual.

Verify that interior and exterior lights are illuminated (if equipped). The exterior light

may flash off for 1 second at 5 second intervals until the tank has reached operating

temperature. See Logic Narrative for more information.

HAWS® Shower and Eye/Facewash

Flow water through an eyewash or shower.

Verify that the exterior light flashes at 1 second intervals and that the audible alarm

sounds.

Press the alarm silence button and verify that the exterior light is flashing, and the

audible alarm is silent.

Deactivate the shower or eyewash that is active, verify that the exterior light is not

flashing at 1 second intervals, and that the audible alarm is silent.

Programmable Logic Controller Display

Set the current time and date in the controller (see instructions below).

Page 10: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 10 of 26

LOGIC DIAGRAM AND NARRATIVE

The program allows for monitoring and controlling tank temperatures. When no faults are present, the tank

temperature, tank heater status, and flow status are displayed (see Figure 5). There are alarm points that

are continuously monitored. These alarms are shown on the display if the fault is active. Alarm conditions

may also be monitored by connecting to a Distributed Control System (DCS) via interposing relays and

terminals provided when provided. See electrical schematic for details. A fault history is also provided to

assist in monitoring the system performance. Additionally, the tank heater performance can be monitored

to assist in determining when maintenance is required.

Figure 4. PLC Display

Accessing the different functions is accomplished by depressing the appropriate key(s) on the display. The

table below lists the key functions:

Key Function

← Display Fault History

↑ Display Tank Heater Monitor

→ Display Current Time

↓ Display Current Date

0 Reset High Tank Temp Alarm

0 & 2 Local Alarm Light Function (Off)

1 & 3 Local Alarm Light Function (On)

Shift + 5 View Time to Preventative Maintenance Shift + 9 Toggle Preventative Maintenance Feature On/Off

Page 11: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 11 of 26

The following table lists the inputs and outputs available with the system. System may not contain all

components.

Input Function Output Function

I-00 Tank Temperature Switch Q-00 Tank Heater Contactor

I-01 Horn Silence Button Q-01 Space Heater Contactor

I-02 Flow Switch or Proximity Switch Q-02 Area/ Alarm Light

I-03 Proximity Switch Q-03 Alarm Horn

I-04 Level Switch Q-04 (DO Q-00) Customer Contact (Common)

I-05 Booth Thermostat Q-05 (DO Q-01) Customer Contact (In Use)

I-06 Door Proximity Switch Q-06 (DO Q-02) Interior Light (Green/White)

AI-01 Tank Temperature Transmitter

NOTE: For model specific program, please contact Haws Services at 1-800-766-5612.

The program consists of a series of charts (sub-routines) that are grouped according to function. Each

chart will be discussed in the following sections.

Tank Control When the tank temperature is below 83°F (28°C), the tank heater contactor will close and the heater

elements will be energized. When the temperature rises above 86°F (30°C), the contactor will open and

the element will become de-energized.

A low-level condition or an over temperature condition (that has not been addressed) will prohibit the

contactor from closing even if the temperature is below the set point. If the tank temperature transmitter

reading falls below 4mA a potential transmitter failure is present and the tank heater contactor will not close.

The customer trouble alarm contacts are monitored in this section of the program. The following conditions

will de-energize output Q-04 (customer contact trouble) when a potential fault is present:

Alarm Modes Low Tank Temperature under 75°F (29°C)

High Tank Temperature over 90°F (32°C)

High Tank Temperature over 95°F (35°C) REQUIRES MANUAL RESET

Low Tank Level

NOTE: Each alarm mode will display an alarm message on the PLC display and only the external light will

flash once every 5 seconds. The Tank high temperature alarm is designed to give a warning by displaying

an alarm message, changing the state of the customer contacts, and flashing the exterior light once every

5 second- intervals, 5 degrees before the temperature rises to a point that requires a manual reset of the

heating equipment. Should the alarm not be addressed before reaching the high set point, then the system

will require additional attention and a manual reset.

Page 12: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 12 of 26

Messages The display messages are controlled by the program. When no alarm modes are present, the display will

present the following conditions:

Tank Heater On (when active)

In Use (when active)

Tank Temperature

When a single alarm mode, also called fault condition, is present, the display will indicate which alarm mode

is present. If more than one alarm exists, the display will cycle through each alarm at 4 second intervals.

Each message will automatically clear when the condition is no longer active or when the corrective action

has been taken. This program also records a message to the “Fault History” chart, which will assign the

time and date when the alarm occurred using the Real Time Clock (RTC) module. Timer counter (TC-05

in conjunction with TC-06) will keep track of the 4 second timing intervals and advance the message display

to the next active alarm (if present).

Real Time Clock (RTC) The RTC module is used to record the date and time for the Fault History (alarm modes) and auto-return

to Winter Mode.

NOTE: If “NO RTC” is shown on PLC display (see Figure 5), remove RTC module by disconnecting from

PLC, re-attach, and cycle the power. If “NO RTC” is still shown, please contact Haws Services at 1-800-

766-5612 as you may need a replacement part.

Figure 5. No RTC - Real Time Clock Display

Fault History The fault history chart keeps track of the time and date of the last occurrence of each fault. When the “left

arrow key” is depressed, the time and date of each fault will be listed on the display. There will be a 4

second delay before the first fault is displayed. Each fault will be listed for 4 seconds as long as the “left

arrow” key is depressed. The time and date of each fault are stored in registers R-004 through R-021. Once

the “left arrow” key is released the display will return to the normal condition display if no faults are present.

Page 13: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 13 of 26

If there are faults in the system, the display will return to the fault display when the “left arrow” key is

released.

In Use Alarms Shower/eyewash activations are monitored via proximity switches connected to I-02 and I-03. When the

shower or eyewash is activated, output Q-05 (in use alarm) will de-energize and engage the customer

contacts. The alarm horn will also energize via Q-03. The exterior light is also controlled in this chart. The

exterior light remains on during normal operation. When the shower or eyewash is activated, the exterior

light will flash on and off at 1 second intervals.

Fault Condition Notification If a fault is active and there is no shower or eyewash activations, the light will flash once every 5 seconds.

This function gives the user an indication of a fault condition if the unit is not connected to plant Distributed

Control System (DCS) via dry contacts provided on the electrical panel layout. To properly connect DCS

to dry contacts, please refer to the model-specific electrical schematic. It is possible to override this function

by simultaneously depressing the “0” and “2” key. Flag F-026 controls this function. It is set as retentive

to maintain the selection after a power outage. These intervals are controlled by TC-00 through TC-04.

NOTE: If a model-specific electrical schematic is not present or additional information is required to connect

DCS to unit, please contact Haws Services at 1-800-766-5612.

Maintenance Required Notification On units containing the “Preventative Maintenance Required” notification feature, the area light will flash

once every 10 seconds when preventative maintenance is required. The notification is factory set to activate

after one year of operation and reactivates each following year.

The operating procedure is as follows:

• To view remaining time until Preventative Maintenance is required, press Shift + 5

• To toggle Preventative Maintenance Required feature on/off, press Shift + 9

o To reset the timer, turn the Preventative Maintenance Required feature off then back on.

The timer will start from 0.

o On/off toggle can also be triggered by the following push button sequence using the alarm

horn silence button.

▪ Press 3 times within 2 seconds, wait 2-5 seconds, and press 3 times within 2

seconds

o Activation of the Preventative Maintenance Required Feature is indicated by 3 short flashes

of the area light accompanied by 3 blips of the alarm horn.

Page 14: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 14 of 26

o Deactivation of the Preventative Maintenance Required Feature is indicated by 4 short

flashes of the area light accompanied by 4 blips of the alarm horn.

Space Heater This space heater control program controls the function of the space heater booth thermostat is connected

to I-05, which will engage the space heater contactor (Q-01). An excessive booth temperature may cause

the scald valve to relieve if the booth temperature approaches 95°F (35°C).

Tank Monitor The tank monitor chart provides a means of monitoring the tank heater performance. This chart records

the actual amount of time that the tank heater contactor is on via registers R-050 through R-052. Counter

TC-14 cycles the chart through the last 3 on/off cycles of the tank heater contactor. TC-13 records the

actual on time of the contactor. When the unit is initially placed in service and has reached operating

temperature for several hours, the on/off cycles should be recorded in the table below. Pressing the “up

arrow” key will display the last three cycles. Each cycle will be displayed for 4 seconds as long as the key

is depressed.

CYCLE ON/OFF TIME

1

2

3

These values can be checked on a routine basis. If the amount of time that the tank heater is on has

increased, it may be an indication that the tank heater needs service or repair.

Tank History This tank history chart controls the display messages recorded by the tank monitor chart. TC-15 sets the

time that each message is displayed. TC-16 is used to increment from “Heater on time 1” through “Heater

on time 3”.

Setting Current Time and Date on the Controller 1. Press the “SHIFT” and “OK” buttons to enter the menu.

2. Press “4” to enter setup.

3. Press “1” to set date or “2” to set time.

4. After date or time is set, press the “SHIFT” and “↑” key to return to setup menu.

The Time and Date can be verified by pressing the “→” or “↓” keys while in the normal operating screen.

NOTE: The exterior light may still be flashing for 1 second every 5 seconds if there is a fault in the system.

Page 15: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 15 of 26

PREVENTIVE MAINTENANCE

Note: These are general instructions applicable to all Haws Model 8720 Overhead Tank Shower

Booths. Additional maintenance activities may apply to particular configurations/options

supplied.

Weekly

• Verify the tank temperature readout on the display reads. 85ºF ± 2ºF (29ºC ± 1ºC).

• Verify area lights located inside and outside the booth are operational.

• Verify space heater is functioning by raising space heater thermostat to a set point above the

ambient temperature. After several minutes the space heater should begin to emit heat. Return

space heater thermostat to 70ºF (21ºC).

Figure 6. Wall Thermostat

• Self-contained combination units shall be visually checked weekly to determine if flushing fluid

needs to be changed or supplemented. Such inspection shall be conducted in accordance with

manufacturer’s instructions.

Monthly

• Check for evidence of leakage on freeze and scald valves.

Quarterly

• Flush Y – strainers (if installed)

• Verify eyewash flows. Alarm light and horn should activate when water is flowing. Verify that

remote alarms connected to plant controls are functioning.

• Verify shower flow. Alarm light and horn should activate when water is flowing. Verify that remote

alarms connected to plant controls are functioning.

Page 16: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 16 of 26

• Drain and refill tank with fresh potable water. Add suitable amount and anti-microbial solution to

tank.

• Take proper precautions to help prevent the growth of potentially harmful bacteria in flushing fluid

tanks. We recommend either of the following procedures:

o Procedure 1: Use suitable Sterile Antimicrobial Preservative Model 9082 to help prevent

the growth of bacteria in flushing fluid tank. The flushing fluid tank should be drained,

flushed and refilled with clean potable water and Sterile Antimicrobial Preservative Model

9082 as directed by the preservative’s manufacturer.

NOTE: Disconnect Model from power source before performing maintenance.

o Procedure 2: Use suitable immersible cleansing stick Model 9084 to help prevent the

growth of bacteria in flushing fluid tank. Model 9084 last up to 3 years and requires

inspection every 6 months.

o Procedure 3: Drain, flush and refill portable units with clean potable water at least once

every week. Thoroughly cleanse tank at least once every month.

• After activating the units for whatever reason, ensure the following steps are implemented:

o Refill tank with potable water to the full level.

o If water is discharged for any reason – follow Procedure 1 or 3 above to ensure that water

quality is maintained.

Annually

• Check tank heater and tank for deposit buildup. Drain tank and clean/replace heater if necessary.

• All valves should be periodically tested; at least once a year, more often if water is dirty.

• Drain tank and verify level switch operation.

• All emergency showers and eye/face washes shall be inspected annually to assure conformance

of ANSI Z358.1. This includes, but not limited to, proper installation, accessible locations, proper

flow rate and temperature of flushing fluid. Please refer to the most current standards document

for more information.

Page 17: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 17 of 26

MAINTENANCE, TESTING, REPAIR

Booth The booth is made of aluminum skins laminated to an insulating foam core then powder coated.

Should cleaning be necessary, a mixture of water with household glass cleaner or rubbing alcohol

can be used. For repairs to small holes in the booth, Sikaflex 1A Construction Sealant, silicone, or

a similar sealant can be used to seal openings in the booth’s surface.

Double Swinging Doors CAUTION: KEEP FINGERS AWAY FROM PINCH POINTS!

The doors have been adjusted at the factory with proper tension to allow for closure of doors.

Should doors need to be adjusted, tension can be changed by adjusting the screws at the top and

bottom of the hinges.

Combination Shower/Eyewash Verify shower and eyewash flow per ANSI requirements.

NOTE: If shower and/or eyewash does not flow per ANSI requirements or at all, consult Haws Services.

Freeze and Scald Valve Scald valve is designed to open before internal water temperature exceeds 100°F (37.8°C).

Freeze is designed to open before internal water temperature drops below 35°F (1.7°C).

NOTE: If valve does not fully open/close, check valve seat for debris or scale build. If no debris or scale

present, consult Haws Corporation.

CAUTION: Extreme hot/cold temperatures in booth may cause valves to open.

For technical support, contact: Haws Services | (800) 766-5612 | www.hawsco.com/services

Page 18: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 18 of 26

TROUBLESHOOTING

TROUBLE REPAIR CHECKLIST

Tank temperature too cold (set point 85F (29ºC)): a) Used recently? Full recovery for each tank and

heater size below:

• 530 gallon/4kW, 14 hours

b) Check controller setting (85ºF). Check for heater

on display if below 85ºF.

c) Check controller for alarms.

d) Check heater circuit fuses F1.

e) Check control voltage and power supply fuses

PFU & CFU.

Tank temperature too hot: a) Check controller setting.

b) Check alarms on controller.

Space heater not on when temperature is below 70°F

(21°C):

a) Check thermostat setting.

b) Check controller display.

c) Check heater fuses F2.

Uneven water flow to eyewash: a) Eyewash must be level.

b) Clogged eyewash head. Clean or replace

eyewash head.

Insufficient water flow to eyewash or shower: a) Check ball valves. Must be open and unclogged.

b) Clogged or malfunctioning siphon

Clear exterior light off: a) Check LED.

b) Check fuses PFU & CFU

Exterior light does not flash and alarm does not sound

when shower or eyewash is activated:

a) Check proximity switch actuation.

b) Check proximity switch wiring connections.

c) Confirm that Q2 and Q3 are powered.

Exterior alarm does not flash but alarm is sounding

when shower or eyewash is activated:

a) Check LED.

b) Check wiring to light.

If “NO RTC” is present on PLC display: a) Reset by removing and reattaching module. If

“NO RTC” is still present, a replacement part is

required.

For technical support, contact:

Haws Services | (800) 766-5612 | www.hawsco.com/services

Page 19: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 19 of 26

SPARE PARTS

Please call Haws Services to order spare parts: 1-800-766-5612

Page 20: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 20 of 26

DRAWINGS

General Arrangement Drawing (0580001082.D-GA)

Page 21: Model 8720 - Hawsco

THE

ATTA

CH

ED D

ESIG

NS

ARE

CO

NSI

DER

ED T

RAD

E SE

CR

ETS

AND

PO

TEN

TIAL

LY P

ATEN

TABL

E. I

N A

CC

OR

DAN

CE

WIT

H C

ON

FID

ENTI

ALIT

Y AN

D

NO

N-D

ISC

LOSU

RE

AGR

EEM

ENT,

TH

ESE

DES

IGN

S IN

AC

TUAL

OR

C

ON

CEP

TUAL

FO

RM

S C

ANN

OT

BE D

ISC

LOSE

D, R

EPR

OD

UC

ED O

R U

SED

W

ITH

OU

T H

AWS'

EXP

RES

S W

RIT

TEN

CO

NSE

NT.

0"

100

1/2

"

179

"

111

"

DO

UBL

E SW

ING

D

OO

RS

ALAR

M H

OR

N(O

PTIO

NAL

)

ALAR

M L

IGH

TFL

ASH

ES W

HEN

SHO

WER

/EYE

WAS

HIS

IN U

SE(O

PTIO

NAL

)

DR

AIN

3" IP

S SL

IP F

IT

TAN

K O

VER

FLO

W

CU

STO

MER

CO

NN

ECTI

ON

TAN

K FI

LL /

WAT

ER S

UPP

LY1-

1/2"

NPT

UN

ION

DIS

CO

NN

ECT

AFTE

R F

ILL

2.5K

WSP

ACE

HEA

TER

(OPT

ION

AL)

79

1/2"

INTE

RIO

R L

IGH

T:G

REE

N-S

TAN

DBY

WH

ITE-

IN U

SE

CO

NTR

OL

PAN

ELSE

E 05

8000

1082

.D-E

L FO

R W

IRIN

G A

ND

EL

ECTR

ICAL

SER

VIC

E D

ETAI

LS

LEVE

L SW

ITC

H

TEM

PER

ATU

RE

TRAN

SMIT

TER

TEM

PER

ATU

RE

SWIT

CH

AIR

INLE

T4K

W T

ANK

HEA

TER

FOR

KLIF

T SL

OTS

0"

53"

83"

44"

SHO

WER

EYE/

FAC

E W

ASH

ALAR

M S

ILEN

CE

PUSH

BU

TTO

N(O

PTIO

NAL

)

0"

11"

55"

0"

11"

"

1 1/2"

64 1/2"

52

1/2"

1 1

/2"

57

1/2"

NO

TES:

DIM

ENSI

ON

S IN

US

INC

HES

1.AL

L TO

LER

ANC

ES:

1/2"

2.ES

TIM

ATED

WEI

GH

T:3.

DR

Y: 2

500

LBS

WET

: 690

0 LB

SAR

EA C

LASS

IFIC

ATIO

N: O

RD

INAR

Y4.

AVAI

LABL

E AM

BIEN

T TE

MPE

RAT

UR

E R

ANG

E: -5

0F

- 120

F5.

RAT

ING

S: C

ON

FIG

UR

ABLE

WIT

H T

YPE

4/4X

JU

NC

TIO

N B

OX

FOR

IND

OO

R O

R6.

OU

TDO

OR

LO

CAT

ION

NO

T AL

L FE

ATU

RES

AR

E ST

AND

ARD

7.

REV

ISIO

NS

REV

DES

CR

IPTI

ON

ECN

DAT

EBY

1IN

ITIA

L R

ELEA

SE55

899/

18/2

020

IR

D C B AABCD

12

34

56

788

76

54

32

1

EF

EF

© 2

020

Haw

s C

orpo

ratio

n - A

ll R

ight

s R

eser

ved.

HAW

S® a

nd o

ther

trad

emar

ks u

sed

in th

ese

mat

eria

ls a

re th

e ex

clus

ive

prop

erty

of H

aws

Cor

pora

tion.

JOB

NU

MBE

R:

CU

STO

MER

INFO

/TAG

#:

APPR

OVA

L D

ATE:

CH

ECKE

D D

ATE:

DR

AWN

DAT

E:

OU

TDO

OR

OVE

RH

EAD

TAN

K C

OM

BIN

ATIO

N S

HO

WER

DB

109

/23/

20

09/2

3/20

1455

KLE

PPE

LAN

ESP

ARKS

, NEV

ADA

8943

1U

SA

NOTI

CE O

F PR

OPR

IETA

RY IN

FORM

ATIO

N

INFO

RM

ATIO

N C

ON

TAIN

ED H

EREI

N IS

TH

E SO

LE

PRO

PER

TY O

F H

AWS

CO

RPO

RAT

ION

AN

D T

HIS

D

OC

UM

ENT

AND

TH

E D

ATA

DIS

CLO

SED

HER

EIN

OR

H

EREW

ITH

IS N

OT

TO B

E R

EPR

OD

UC

ED, U

SED

, OR

D

ISC

LOSE

D IN

WH

OLE

OR

IN P

ART

TO A

NYO

NE

WIT

HO

UT

THE

PER

MIS

SIO

N O

F H

AWS

CO

RPO

RAT

ION

.

THIR

D A

NG

LE P

RO

JEC

TIO

N

GA

APPR

OVE

D B

Y:

DB

TITL

E

0580

0010

82.D

-GA

CH

ECKE

D B

Y:

DR

AWN

BY:

REV

.

SH 1

OF

1

CPA

RT

NO

.SI

ZESC

ALE

1:3

2

Page

21

of 2

6

Page 22: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 22 of 26

Electrical Schematic (0580001082.D-EL)

Page 23: Model 8720 - Hawsco

NO

TE

S:

1.

AR

EA

CL

AS

SIF

ICA

TIO

N: O

RD

INA

RY

2.

AV

AIL

AB

LE

AM

BIE

NT

TE

MP

ER

AT

UR

E R

AN

GE

: -5

0°F

- 1

20

°F

3.

RA

TIN

GS

: C

ON

FIG

UR

AB

LE

WIT

H T

YP

E 4

/4X

JU

NC

TIO

N B

OX

FO

R I

ND

OO

R O

R O

UT

DO

OR

LO

CA

TIO

N

CD

43

CS

CA

LE

SIZ

EP

AR

T N

UM

BE

RR

EV

TH

IRD

AN

GLE

PR

OJE

CT

ION

NO

TIC

E O

F P

RO

PR

IET

AR

Y IN

FO

RM

AT

ION

INF

OR

MA

TIO

N C

ON

TA

INE

D H

ER

EIN

IS

TH

E S

OL

E P

RO

PE

RT

Y O

F

HA

WS

CO

RP

OR

AT

ION

AN

D T

HIS

DO

CU

ME

NT

AN

D T

HE

DA

TA

DIS

CL

OS

ED

HE

RE

IN O

R H

ER

EW

ITH

IS

NO

T T

O B

E R

EP

RO

DU

CE

D,

US

ED

, O

R D

ISC

LO

SE

D IN

WH

OL

E O

R I

N P

AR

T T

O A

NY

ON

E W

ITH

OU

T

TH

E P

ER

MIS

SIO

N O

F H

AW

S C

OR

PO

RA

TIO

N.

OF

SH

CU

ST

OM

ER

IN

FO

/TA

G #

:

DA

TE

TIT

LE

:

DR

AW

N

AP

PR

OV

ED

CH

EC

KE

D

AP

PR

OV

AL

S

AB

21

B AD C

23

4

1455 K

LE

PP

E L

AN

E

SP

AR

KS

, N

EV

AD

A

89431

US

A

H

aw

s C

orp

ora

tio

n -

All

Rig

hts

Re

serv

ed

.C

HA

WS

® a

nd

oth

er

trad

em

ark

s u

sed

in

the

se

ma

teri

als

are

the

exclu

siv

e p

rope

rty o

f H

aw

s C

orp

ora

tio

n.

TH

E A

TT

AC

HE

D D

ES

IGN

S A

RE

CO

NS

IDE

RE

D T

RA

DE

SE

CR

ET

S

AN

D P

OT

EN

TIA

LL

Y P

AT

EN

TA

BLE

. I

N A

CC

OR

DA

NC

E W

ITH

CO

NF

IDE

NT

IALIT

Y A

ND

NO

N-D

ISC

LO

SU

RE

AG

RE

EM

EN

T,

TH

ES

E D

ES

IGN

S IN

AC

TU

AL

OR

CO

NC

EP

TU

AL F

OR

MS

CA

NN

OT

BE

DIS

CL

OS

ED

, R

EP

RO

DU

CE

D O

R U

SE

D W

ITH

OU

T

HA

WS

' E

XP

RE

SS

WR

ITT

EN

CO

NS

EN

T.

RE

V

RE

VIS

ION

S

BY

DA

TE

DE

SC

RIP

TIO

NE

CN

JO

B N

UM

BE

R

105

800

010

82.D

-EL

1

CO

MB

INA

TIO

N S

HO

WE

R09

/22

/20

DB

09

/22

/20

DB

.

11E

LE

CT

RIC

AL

87

20 -

OU

TD

OO

R O

VE

RH

EA

D T

AN

K

09

/18

/20

IR

202

0

IR09

/16

/20

55

89

INIT

IAL R

ELE

AS

E1

Page

23

of 2

6

Page 24: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720 Page 24 of 26

Piping and Instrumentation Diagram (0580001082.D-PID)

Page 25: Model 8720 - Hawsco

WA

TE

R S

TO

RA

GE

TA

NK

530

GA

L

85°F

WA

TE

R O

VE

RF

LO

W

TO

AT

M

AIR

IN

LE

T

(DO

N N

OT

BLO

CK

)

FL

OW

CO

NT

RO

L

CU

ST

OM

ER

CO

NN

EC

TIO

N

TA

NK

FIL

L /

WA

TE

R S

UP

PLY

1-1

/2"

NP

T U

NIO

N

RE

MO

VE

SU

PP

LY

LIN

E A

FT

ER

FIL

LIN

G

SH

OW

ER

PU

LL H

AN

DLE

W/ P

RO

X S

WIT

CH

SH

OW

ER

HE

AD

1"

NP

T

PU

SH

FLA

G

W/ P

RO

X S

WIT

CH

AN

TI S

CA

LD

VA

LV

EA

NT

I F

RE

EZ

E V

ALV

E

EX

PA

NS

ION

PLU

G

TA

NK

HE

AT

ER

4K

W

CD

43

CS

CA

LE

SIZ

EP

AR

T N

UM

BE

RR

EV

TH

IRD

AN

GLE

PR

OJE

CT

ION

NO

TIC

E O

F P

RO

PR

IET

AR

Y IN

FO

RM

AT

ION

INF

OR

MA

TIO

N C

ON

TA

INE

D H

ER

EIN

IS

TH

E S

OL

E P

RO

PE

RT

Y O

F

HA

WS

CO

RP

OR

AT

ION

AN

D T

HIS

DO

CU

ME

NT

AN

D T

HE

DA

TA

DIS

CL

OS

ED

HE

RE

IN O

R H

ER

EW

ITH

IS

NO

T T

O B

E R

EP

RO

DU

CE

D,

US

ED

, O

R D

ISC

LO

SE

D IN

WH

OL

E O

R I

N P

AR

T T

O A

NY

ON

E W

ITH

OU

T

TH

E P

ER

MIS

SIO

N O

F H

AW

S C

OR

PO

RA

TIO

N.

OF

SH

CU

ST

OM

ER

IN

FO

/TA

G #

:

DA

TE

TIT

LE

:

DR

AW

N

AP

PR

OV

ED

CH

EC

KE

D

AP

PR

OV

AL

S

AB

21

B AD C

23

4

1455 K

LE

PP

E L

AN

E

SP

AR

KS

, N

EV

AD

A

89431

US

A

H

aw

s C

orp

ora

tio

n -

All

Rig

hts

Re

serv

ed

.C

HA

WS

® a

nd

oth

er

trad

em

ark

s u

sed

in

the

se

ma

teri

als

are

the

exclu

siv

e p

rope

rty o

f H

aw

s C

orp

ora

tio

n.

TH

E A

TT

AC

HE

D D

ES

IGN

S A

RE

CO

NS

IDE

RE

D T

RA

DE

SE

CR

ET

S

AN

D P

OT

EN

TIA

LL

Y P

AT

EN

TA

BLE

. I

N A

CC

OR

DA

NC

E W

ITH

CO

NF

IDE

NT

IALIT

Y A

ND

NO

N-D

ISC

LO

SU

RE

AG

RE

EM

EN

T,

TH

ES

E D

ES

IGN

S IN

AC

TU

AL

OR

CO

NC

EP

TU

AL F

OR

MS

CA

NN

OT

BE

DIS

CL

OS

ED

, R

EP

RO

DU

CE

D O

R U

SE

D W

ITH

OU

T

HA

WS

' E

XP

RE

SS

WR

ITT

EN

CO

NS

EN

T.

RE

V

RE

VIS

ION

S

BY

DA

TE

DE

SC

RIP

TIO

NE

CN

JO

B N

UM

BE

R

N/A

05

800

010

82.D

-PID

1

CO

MB

INA

TIO

N S

HO

WE

R09

/22

/20

DB

09

/22

/20

DB

11P

&ID

8720

- O

UT

DO

OR

OV

ER

HE

AD

TA

NK

09

/18

/20

IR

202

0

NO

TE

S:

1.

AR

EA

CL

AS

SIF

ICA

TIO

N:

OR

DIN

AR

Y

2.

AV

AIL

AB

LE

AM

BIE

NT

TE

MP

ER

AT

UR

E R

AN

GE

: -5

0°F

- 1

20°F

3.

RA

TIN

GS

: C

ON

FIG

UR

AB

LE

WIT

H T

YP

E 4

/4X

JU

NC

TIO

N B

OX

FO

R IN

DO

OR

OR

OU

TD

OO

R L

OC

AT

ION

LE

VE

L

SW

ITC

H

TE

MP

ER

AT

UR

E

TR

AN

SM

ITT

ER

TE

MP

ER

AT

UR

E

SW

ITC

H

TE

MP

ER

AT

UR

E

GU

AG

E

IR09

/16

/20

55

89

INIT

IAL R

ELE

AS

E1

Page

25

of 2

6

Page 26: Model 8720 - Hawsco

HAWS® P/N 0580001082 Rev.1 9/20 Model 8720

LIMITED WARRANTY

HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations, or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale.

The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries.

NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL:

HAWS SERVICES: 1-800-766-5612

FOR CUSTOMER SERVICE: 1-888-640-4297

For more information on Haws products, see our website: www.hawsco.com

© 2020 Haws® Corporation – All Rights Reserved