MODBUS SENSOR LINE - LAMBRECHT · 2019. 3. 18. · LAMBRECHT meteo GmbH Tel +49 (0) 551-4958-0 ·...
Transcript of MODBUS SENSOR LINE - LAMBRECHT · 2019. 3. 18. · LAMBRECHT meteo GmbH Tel +49 (0) 551-4958-0 ·...
-
LAMBRECHT meteo GmbH Tel +49 (0) 551-4958-0 · [email protected] · www.lambrecht.net
PRODUCT-VIEW
Meteorological performance is brought to industrial standard by Lambrecht’s approved sensors combined with Modbus Meteorological performance is brought to industrial standard by Lambrecht’s approved sensors combined with Modbus RTU. This common Modbus standard simplifies the integration of the sensors into networks and allows the construction RTU. This common Modbus standard simplifies the integration of the sensors into networks and allows the construction of long communication distances. All the Lambrecht meteo Modbus sensors have a 24 VDC power supply and the same of long communication distances. All the Lambrecht meteo Modbus sensors have a 24 VDC power supply and the same connections (12 plug, 4-pin) as well.connections (12 plug, 4-pin) as well.ll
The high quality of our sensors in combination with the interference-proof communication ensures a high integrity of The high quality of our sensors in combination with the interference-proof communication ensures a high integrity of your data. Your connection to the industrial world with professionally approved Lambrecht meteo sensors.your data. Your connection to the industrial world with professionally approved Lambrecht meteo sensors.
Meteorological performance is brought to industrial standard by Lambrecht’s approved sensors combined with Modbus RTU. This common Modbus standard simplifies the integration of the sensors into networks and allows the construction of long communication distances. All the Lambrecht meteo Modbus sensors have a 24 VDC power supply and the same connections (12 plug, 4-pin) as well.
The high quality of our sensors in combination with the interference-proof communication ensures a high integrity of your data. Your connection to the industrial world with professionally approved Lambrecht meteo sensors.
SENSOR LINESENSOR LINESENSOR LINEMODBUS
PRO-MODBUSWind direction and wind speed
Weighing precipi-tation sensor
rain[e] Modbus
LAMBRECHT meteo GmbH Tel +49 (0) 551-4958-0 · [email protected] · www.lambrecht.net
PYRANOMETER “16131 Modbus”
Global Radiation Id-No. 00.16130.501030
Id-No. 00.16131.501030Global Radiation
Global Radiation
sun[e] Modbus Pyranometer Class A (IEC 61724-1:2017)
Id-No. 00.16103.501060PYRANOMETER “16103 Modbus”
Temperature · Humi-dity · Pressure
THP[pro] ModbusDigital "Class A" pyranometer
sun[e] Modbus
We know the weather!
Measuring range -400...4000 W/m² • global radiation within a range of 285...3000 nm
Accuracy Secondary standard • Class A2 % (WMO daily totals)
Resolution 0.05 W/m2Range of application -40...+80 °CPower supply 24 VDC (8...30 VDC)
Measuring range 0...3000 W/m2 • global radiation within a range of 285...3000 nm
Accuracy First class Class B • 5 % (WMO daily totals)
Resolution 0.01 W/m²Range of application -40...+80 °CPower supply 24 VDC (8...30 VDC)
Measuring range 0...2000 W/m2 • global radiatition within a range of 285...3000 nm
Accuracy Second class • Class C10 % (WMO daily totals)
Resolution 0.2 W/m²Range of application -40...+80 °CPower supply 24 VDC (5...30 VDC)
-
u[sonic] Modbus
Measuring range wind direction 0...360° Measuring range wind speed 0.3...75 m/s Accuracy wind direction ± 1° Accuracy wind speed 0.5 m/s at 0.3...5 m/s • 0.1 m/s
2 % FS at 5.1...50 m/sResolution wind direction 1° Resolution wind speed < 0.1 m/sRange of application -40...+70 °C • 0...100 % r. h. • max. gust 80 m/sPower supply 24 VDC (20...28 VDC) • 18 W heating
Measuring range wind direction 0...360° Measuring range wind speed 0...75 m/s Accuracy wind direction < 2° (> 1 m/s ) RMSE Accuracy wind speed 0.2 m/s RMSE (v < 10 m/s);
2 % RMSE (10 m/s < v < 65 m/s)Resolution wind direction 0.1° Resolution wind speed 0.1 m/sRange of application -40...+70 °C • 0...100 % r. h. • max. gust 100 m/sPower supply 24 VDC (19... 29 VDC) 6O W heating •
ARCO-Modbus
Wind direction and wind speed Id-No. 00.16470.000130
Id-No. 00.14581.030430Wind direction and wind speed
PRO-Modbus
Measuring range wind direction 0...360° Measuring range wind speed 0.7...50 m/s Accuracy wind direction 2° Accuracy wind speed 0.5 m/s at 0.7...5 m/s and
2 % FS at 5.02...50 m/sResolution wind direction 2°Resolution wind speed < 0.02 m/sRange of application -30...+70 °C • 0...100 % r. h. • max. gust 60 m/sPower supply 24 VDC (20...32 VDC) • 18 W heating
Measuring range wind direction 0...360° Measuring range wind speed 0.5...75 m/s Accuracy wind direction 2° Accuracy wind speed 0.3 m/s ≤ 10 m/s
0.5 m/s < 60 m/sResolution wind direction < 1° Resolution wind speed < 0.1 m/sRange of application -40...+70 °C • 0...100 % r. h. • max. gust 100 m/sPower supply 24 VDC (20...32 VDC) 8 W heating • 1
INDUSTRY-Modbus
Wind direction and wind speedWind direction Id-No. 00.14523.131030 Wind speed Id-No. 00.14524.101030
Wind direction and wind speedWind direction Id-No. 00.14567.110030Wind speed Id-No. 00.14577.110030
rain[e]-Modbus
THP[pro] Modbus
Weighing precipitatition sensor Id-No. 00.15184.400100
Id-No. 00.08095.100030Temperature · Humidity · Pressure
Measuring range -40 ... +80 °C Temperature influence ±100 ppm/K of full scale Resolution 16 bit Range of application -40...+80 °C Power supply 24 VDC (18...30 VDC)
Pt100 Modbus Converter
MODULE TEMPERATURE SENSOR Id-No. 00.08290.000030
Id-No. 00.08790.000000
Measuring range temperature -40...+70 °C Measuring range humidity 0...100 % r. h.Measuring range bar. pressure 500...1100 hPa
1)Accuracy temperature ± 0.1 K (0…60 °C) • ± 0.2 K (-40…0 °C) 1)Accuracy humidity typ. ± 1.5 % (0...80 %) r. h. • ± 2 % (> 80 %) r. h.
Accuracy humidity bar. pressure ± 2 hPa (-30...+70 °C) • ± 1 hPa (-10...+60 °C)Resolution temperature 0.1 °C Resolution humidity 0.1 % r. h.Resolution bar. pressure 0.1 hPaRange of application -40...+70 °C • 0...100 % r.h. • 500...1100 hPaPower supply 24 VDC (4.8...33 VDC)
1) ventilated sensor shelter recommended
Measuring range (amount) without limitatition (0.005…∞ mm)Measuring range (intensity) 0....20 mm/minAccuracy 0,1 mm < 6 mm/min and 2 % at ≤ 6 mm/min Resolution (intensity) 0.001 mm/min resp. 0.001 mm/hResolution (amount) 0.001 mmRange of application -40...+70 °C • 0...20 mm/minPower supply 24 VDC (9.8...32 VDC) 140 W heating •
Measuring range -40...+105 °C Accuracy (0.3 + 0,005 · |T|) Resolution depends on data aquisition unitRange of application -40...+105 °C • 0...100 % r.h.Power supply non passiv Pt100 •
-
u[sonic] Modbus
Measuring range wind direction 0...360° Measuring range wind speed 0.3...75 m/s Accuracy wind direction ± 1° Accuracy wind speed 0.5 m/s at 0.3...5 m/s • 0.1 m/s
2 % FS at 5.1...50 m/sResolution wind direction 1° Resolution wind speed < 0.1 m/sRange of application -40...+70 °C • 0...100 % r. h. • max. gust 80 m/sPower supply 24 VDC (20...28 VDC) • 18 W heating
Measuring range wind direction 0...360° Measuring range wind speed 0...75 m/s Accuracy wind direction < 2° (> 1 m/s ) RMSE Accuracy wind speed 0.2 m/s RMSE (v < 10 m/s);
2 % RMSE (10 m/s < v < 65 m/s)Resolution wind direction 0.1° Resolution wind speed 0.1 m/sRange of application -40...+70 °C • 0...100 % r. h. • max. gust 100 m/sPower supply 24 VDC (19... 29 VDC) 6O W heating •
ARCO-Modbus
Wind direction and wind speed Id-No. 00.16470.000130
Id-No. 00.14581.030430Wind direction and wind speed
PRO-Modbus
Measuring range wind direction 0...360° Measuring range wind speed 0.7...50 m/s Accuracy wind direction 2° Accuracy wind speed 0.5 m/s at 0.7...5 m/s and
2 % FS at 5.02...50 m/sResolution wind direction 2°Resolution wind speed < 0.02 m/sRange of application -30...+70 °C • 0...100 % r. h. • max. gust 60 m/sPower supply 24 VDC (20...32 VDC) • 18 W heating
Measuring range wind direction 0...360° Measuring range wind speed 0.5...75 m/s Accuracy wind direction 2° Accuracy wind speed 0.3 m/s ≤ 10 m/s
0.5 m/s < 60 m/sResolution wind direction < 1° Resolution wind speed < 0.1 m/sRange of application -40...+70 °C • 0...100 % r. h. • max. gust 100 m/sPower supply 24 VDC (20...32 VDC) 8 W heating • 1
INDUSTRY-Modbus
Wind direction and wind speedWind direction Id-No. 00.14523.131030 Wind speed Id-No. 00.14524.101030
Wind direction and wind speedWind direction Id-No. 00.14567.110030Wind speed Id-No. 00.14577.110030
rain[e]-Modbus
THP[pro] Modbus
Weighing precipitatition sensor Id-No. 00.15184.400100
Id-No. 00.08095.100030Temperature · Humidity · Pressure
Measuring range -40 ... +80 °CTemperature influence ±100 ppm/K of full scale Resolution 16 bit Range of application -40...+80 °CPower supply 24 VDC (18...30 VDC)
Pt100 Modbus Converter
MODULE TEMPERATURE SENSOR Id-No. 00.08290.000030
Id-No. 00.08790.000000
Measuring range temperature -40...+70 °C Measuring range humidity 0...100 % r. h.Measuring range bar. pressure 500...1100 hPa
1)Accuracy temperature ± 0.1 K (0…60 °C) • ± 0.2 K (-40…0 °C) 1)Accuracy humidity typ. ± 1.5 % (0...80 %) r. h. • ± 2 % (> 80 %) r. h.
Accuracy bar. pressure ± 2 hPa (-30...+70 °C) • ± 1 hPa (-10...+60 °C)Resolution temperature 0.1 °C Resolution humidity 0.1 % r. h.Resolution bar. pressure 0.1 hPaRange of application -40...+70 °C • 0...100 % r.h. • 500...1100 hPaPower supply 24 VDC (4.8...33 VDC)
1) ventilated sensor shelter recommended
Measuring range (amount) without limitatition (0.005…∞ mm) Measuring range (intensity) 0....20 mm/minAccuracy 0,1 mm < 6 mm/min and 2 % at ≤ 6 mm/min Resolution (intensity) 0.001 mm/min resp. 0.001 mm/h Resolution (amount) 0.001 mmRange of application -40...+70 °C • 0...20 mm/minPower supply 24 VDC (9.8...32 VDC) 140 W heating •
Measuring range -40...+105 °CAccuracy (0.3 + 0,005 · |T|) Resolution depends on data aquisition unitRange of application -40...+105 °C • 0...100 % r.h.Power supply non passiv Pt100 •
-
LAMBRECHT meteo GmbH Tel +49 (0) 551-4958-0 · [email protected] · www.lambrecht.net
PRODUCT-VIEW
Meteorological performance is brought to industrial standard by Lambrecht’s approved sensors combined with Modbus Meteorological performance is brought to industrial standard by Lambrecht’s approved sensors combined with Modbus RTU. This common Modbus standard simplifies the integration of the sensors into networks and allows the construction RTU. This common Modbus standard simplifies the integration of the sensors into networks and allows the construction of long communication distances. All the Lambrecht meteo Modbus sensors have a 24 VDC power supply and the same of long communication distances. All the Lambrecht meteo Modbus sensors have a 24 VDC power supply and the same connections (12 plug, 4-pin) as well.connections (12 plug, 4-pin) as well.ll
The high quality of our sensors in combination with the interference-proof communication ensures a high integrity of The high quality of our sensors in combination with the interference-proof communication ensures a high integrity of your data. Your connection to the industrial world with professionally approved Lambrecht meteo sensors.your data. Your connection to the industrial world with professionally approved Lambrecht meteo sensors.
Meteorological performance is brought to industrial standard by Lambrecht’s approved sensors combined with Modbus RTU. This common Modbus standard simplifies the integration of the sensors into networks and allows the construction of long communication distances. All the Lambrecht meteo Modbus sensors have a 24 VDC power supply and the same connections (12 plug, 4-pin) as well.
The high quality of our sensors in combination with the interference-proof communication ensures a high integrity of your data. Your connection to the industrial world with professionally approved Lambrecht meteo sensors.
SENSOR LINESENSOR LINESENSOR LINEMODBUS
PRO-MODBUSWind direction and wind speed
Weighing precipi-tation sensor
rain[e] Modbus
LAMBRECHT meteo GmbH Tel +49 (0) 551-4958-0 · [email protected] · www.lambrecht.net
PYRANOMETER “16131 Modbus”
Global Radiation Id-No. 00.16130.501030
Id-No. 00.16131.501030Global Radiation
Global Radiation
sun[e] Modbus Pyranometer Class A (IEC 61724-1:2017)
Id-No. 00.16103.501060PYRANOMETER “16103 Modbus”
Temperature · Humi-dity · Pressure
THP[pro] ModbusDigital "Class A" pyranometer
sun[e] Modbus
We know the weather!
Measuring range -400...4000 W/m² • global radiationwithin a range of 285...3000 nm
Accuracy Secondary standard • Class A2 % (WMO daily totals)
Resolution 0.05 W/m2Range of application -40...+80 °CPower supply 24 VDC (8...30 VDC)
Measuring range 0...3000 W/m2 • global radiation within a range of 285...3000 nm
Accuracy First class Class B • 5 % (WMO daily totals)
Resolution 0.01 W/m²Range of application -40...+80 °C Power supply 24 VDC (8...30 VDC)
Measuring range 0...2000 W/m2 • global radiatition within a range of 285...3000 nm
Accuracy Second class • Class C10 % (WMO daily totals)
Resolution 0.2 W/m²Range of application -40...+80 °C Power supply 24 VDC (5...30 VDC)