MLM 226 Faceplates Installation Guide -...

8
1 MLM 226 Faceplates • Installation Guide MLM 226 Faceplates Installation Guide MLM 226 Faceplates This guide provides instructions for installing the following Extron MediaLink Mounting Options faceplates, which are designed for use with the MLC 226 IP MediaLink Controller. The MLM 226 L, MLM 226 3GWP, or MLM 226 5GWP faceplate is shipped with the MLC 226 IP controller, depending on the controller configuration that is ordered. The rest of the mounting options described below may be ordered separately as replacements, or for use with an MLC 226 IP that is ordered without a faceplate. MLM 226 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W) lectern/ furniture-mounting faceplate. This faceplate is required when you are mounting an MLC 226 IP using an optional UCM RAAP or UCM 10X8P mounting kit. Part numbers: 70-342-02 (black), 70-342-03 (white), 70-342-05 (RAL9010 white) MLM 226 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W) lectern/furniture-mounting faceplate with an opening that accommodates four single-space AAPs Part numbers: 70-343-02 (black), 70-343-03 (white), 70-343-05 (RAL9010 white) MLM 226 3GWP — A three-gang (4.50" H x 6.40" W [11.43 cm H x 16.26 cm W]) faceplate that can be mounted to a mud ring (mounting bracket), an Extron Surface Mount Box, an Extron External Wall Box, or a standard electrical box Part numbers: 70-376-02 (black), 70-376-03 (white), 70-376-05 (RAL9010 white) 68-919-01, Rev. D 08 07

Transcript of MLM 226 Faceplates Installation Guide -...

Page 1: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

1MLM 226 Faceplates • Installation Guide

MLM 226 Faceplates Installation Guide

MLM 226 FaceplatesThis guide provides instructions for installing the following Extron MediaLink™

Mounting Options faceplates, which are designed for use with the MLC 226 IPMediaLink Controller.

The MLM 226 L, MLM 226 3GWP, or MLM 226 5GWP faceplate is shippedwith the MLC 226 IP controller, depending on the controller configuration that isordered. The rest of the mounting options described below may be orderedseparately as replacements, or for use with an MLC 226 IP that is ordered withouta faceplate.

• MLM 226 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W) lectern/furniture-mounting faceplate. This faceplate is required when you are mountingan MLC 226 IP using an optional UCM RAAP or UCM 10X8P mounting kit.Part numbers: 70-342-02 (black), 70-342-03 (white), 70-342-05 (RAL9010 white)

• MLM 226 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W)lectern/furniture-mounting faceplate with an opening that accommodates foursingle-space AAPsPart numbers: 70-343-02 (black), 70-343-03 (white), 70-343-05 (RAL9010 white)

• MLM 226 3GWP — A three-gang (4.50" H x 6.40" W [11.43 cm H x 16.26 cm W])faceplate that can be mounted to a mud ring (mounting bracket), an ExtronSurface Mount Box, an Extron External Wall Box, or a standard electrical boxPart numbers: 70-376-02 (black), 70-376-03 (white), 70-376-05 (RAL9010 white)

68-919-01, Rev. D08 07

Page 2: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

MLM 226 Faceplates Installation Guide, cont’d

MLM 226 Faceplates • Installation Guide2

• MLM 226 5GWP — A five-gang (4.50" H x 10.04" W [11.43 cm H x 25.50 cmW]) faceplate with an opening that accommodates four single-space AAPs. Itcan be mounted to a mud ring, an Extron Surface Mount Box, an ExtronExternal Wall Box, or a standard electrical box.Part numbers: 70-377-02 (black), 70-377-03 (white), 70-377-05 (RAL9010white)

• MLM 226 7GWP — A seven-gang (4.50" H x 13.665" W [11.43 cm H x34.71 cm W]) faceplate with two openings that accommodate four single-space AAPs each (eight AAPs total). It can be mounted to a mud ring, anExtron Surface Mount Box, an Extron External Wall Box, or a standardelectrical box.Part numbers: 70-340-02 (black), 70-340-03 (white), 70-340-05 (RAL9010white)

Replacing an MLC 226 IP Faceplate with an MLMFaceplate

1. If your MLC controller is already installed in a wall or furniture, remove thefour screws that attach it to its mounting surface (marked a in the diagramon the next page), and lift it out.

2. After the MLC has been removed from the wall or furniture, use a smallPhillips screwdriver to remove the four faceplate attachment screws (b in thediagram on the next page), and save them for later use.

CAUTION Do not remove the four faceplate screws while the MLC is installed in awall or furniture, or the controller may fall down into the wall orfurniture.

Page 3: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

3MLM 226 Faceplates • Installation Guide

Extron MLC 226 IP

DISPLAY

1 2 3 4 5 6

VOLUME

CONFIG IR

ON OFF PICMUTE

VCR DVD

PC AUTOIMAGE

LAPTOPDOCCAM

1 1

11

2

2 2

2

3. Lift the faceplate off the MLC 226 IP, as shown below.

OFF

ON

PC VCR

DVD

DOC

CAM

PIC

MUTE

AUTO

IMAGE

LAPTOP

Extron

DISPLAY1

2

3

4

5

6

VOLUME CONFIG

IR

MLC 226 IP

4. Align the openings in the new MLM faceplate with the controller’s buttons,knob, and LEDs, then place the new faceplate on the MLC 226 IP.

5. Replace the four screws removed in step 2, and hand tighten them.

6. Install the MLC 226 IP controller with the MLM 226 faceplate in a wall orfurniture as appropriate.

Page 4: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

MLM 226 Faceplates Installation Guide, cont’d

MLM 226 Faceplates • Installation Guide4

TemplatesUse one of the following templates as a guide to measure and mark the hole forinstalling the MLM 226 faceplate with an attached MLC 226 IP. (Refer to yourMLC 226 IP user’s manual for instructions on preparing the mounting site.)

CAUTION These templates are not to scale. Use the dimensions shown in thetemplates as reference guidelines for measuring and drawing the rectanglethat will be cut out.

The MLC controller requires a depth of at least 2.0" (5.1 cm) inside the wall orfurniture.

MLM 226 L and MLC 226 IP L template

6.5" (16.5 cm)

Cut-Out Template for Extron's MLM 226 L and MLC 226 IP L

TEMPLATE IS NOT FULL SIZE.

To install MLC 226 IPand MLM 226 Ldirectly into furniture,cut along this line.

Top Panel

2.9" (7.4 cm)

5.4" (13.7 cm)

SURFACE CUT-OUT AREA FOR FURNITURE MOUNT

3.15" (8.0 cm)

Location of MLC 226 IP

.295" (0.75 cm)

(4 places)

.250" (0.64 cm)

(4 places)

Page 5: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

5MLM 226 Faceplates • Installation Guide

MLM 226 LAAP template

.250" (0.64 cm)

2.9" (7.4 cm)

8.9" (22.6 cm)

SURFACE CUT-OUT AREA FOR

FURNITURE MOUNT

10" (25.4 cm)

Cut-Out Template for Extron's MLM 226 LAAP

TEMPLATE IS NOT FULL SIZE.

To install MLC 226 IPand MLM 226 LAAP directly into furniture,cut along this line.

Top Panel

Location of MLC 226 IP

3.15" (8.0 cm)

.295" (0.75 cm)

Page 6: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

MLM 226 Faceplates Installation Guide, cont’d

MLM 226 Faceplates • Installation Guide6

MLM 226 3GWP and MLC 226 IP template

6.4"(16.26 cm)

Cut-Out Template for Extron's MLM 226 3GWP and MLC 226 IP

TEMPLATE IS NOT FULL SIZE.

To install MLC 226 IPand MLM 226 3GWPdirectly into furniture,cut along this line.

Top Panel

2.9"(7.4 cm)

5.4"(13.7 cm)

SURFACE CUT-OUT AREAFOR FURNITURE MOUNT

4.5"(11.4 cm)

Location of MLC 226 IP

Page 7: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

7MLM 226 Faceplates • Installation Guide

MLM 226 5GWP and MLC 226 IP AAP template

2.9" (7.4 cm)

8.9" (22.6 cm)

SURFACE CUT-OUT AREA FOR

FURNITURE MOUNT

10.04"(25.5 cm)

Cut-Out Template for Extron's MLM 226 5GWP and MLC 226 IP AAP

TEMPLATE IS NOT FULL SIZE.

To install MLC 226 IP and MLM 226 5GWP directly into furniture, cut along this line.

Top Panel

Location of MLC 226 IP

4.5" (11.4 cm)

Page 8: MLM 226 Faceplates Installation Guide - media.extron.commedia.extron.com/download/files/userman/MLM226... · MLM 226 Faceplates • Installation Guide 1 MLM 226 Faceplates Installation

MLM 226 Faceplates Installation Guide, cont’d

MLM 226 Faceplates • Installation Guide8 © 2007 Extron Electronics. All rights reserved.

Extron Electronics, USA1230 South Lewis StreetAnaheim, CA 92805800.633.9876 714.491.1500 FAX 714.491.1517

Extron Electronics, EuropeBeeldschermweg 6C3821 AH Amersfoort, The Netherlands+800.3987.6673 +31.33.453.4040FAX +31.33.453.4050

Extron Electronics, Asia135 Joo Seng Rd. #04-01PM Industrial Bldg., Singapore 368363+800.7339.8766 +65.6383.4400 FAX +65.6383.4664

Extron Electronics, JapanKyodo Building, 16 IchibanchoChiyoda-ku, Tokyo 102-0082Japan+81.3.3511.7655 FAX +81.3.3511.7656www.extron.com

MLM 226 7GWP template

2.9" (7.4 cm)

12.7"(32.3 cm)

SURFACE CUT-OUT AREA FOR

FURNITURE MOUNT

13.665"(34.71 cm)

Cut-Out Template for Extron's MLM 226 7GWP

TEMPLATE IS NOT FULL SIZE.

To install MLC 226 IP and MLM 226 7GWP directly into furniture, cut along this line.

Top Panel

Location of MLC 226 IP

4.5" (11.4 cm)