MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the...

16
MISSION CRITICAL FACILITIES

Transcript of MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the...

Page 1: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES

Page 2: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 2

CONSTRUCTION FIRM

Roebbelen Contracting, Inc.1241 Hawks Flight CourtEl Dorado Hills, CA 95762(916) 939-4000 | (916) 939-4028 [email protected]

Contact: Robert Kjome, Executive Vice President

BUSINESS/LICENSE

Date Firm Established: 1997Type of Business: CorporationContractor License: 734124License Classification: A, B, C-8, and C-13 License Certifications: HAZ and ASB

OWNERS

Kenneth Wenham, PresidentRobert Kjome, Executive Vice PresidentRobert McLean, Executive Vice PresidentFrank Lindsay, Vice President

SUMMARY

Roebbelen was founded by Hans Roebbelen in 1959 in Sacramento, California. Reorganized and incorporated in 1997, Roebbelen is an award-winning construction corporation dedicated to satisfying the needs and requirements of every client. Roebbelen specializes in the construction of institutional, commercial and industrial projects. Roebbelen is headquartered in El Dorado Hills, California.

PERSONNEL/STAFF EXPERIENCE

Roebbelen currently employes 313 employees. Five of our employees are officers, ten are key employees, and 298 are permanent employees. There are approximately 45 employees with professional background in construction management, architecture, civil engineering, structural engineering, mechanical engineering, electrical engineering and certified public accounting. Thirty-six percent of Roebbelen’s employees have been with the company for over ten years.

SERVICES OFFERED

Roebbelen specializes in mission critical, public works and healthcare projects. We provides lease-leaseback, construction management, design-build, general contracting, and value analysis services to our clients. We are dedicated to delivering the very best construction development services in value and service on every project we build.

COMPANY EXPERIENCE

Roebbelen brings over 50 years of experience to this specialized type of construction. We work diligently drawing on our experiences to raise the quality, speed and value of each project we undertake. Annually we complete between $85 and $130 million dollars of work for one of the nations leading telecommunications companies. This work includes minor tenant improvements to ground-up mission critical facilities.

Roebbelen is uniquely positioned to provide you with superior construction management services for all of your planning, design and construction services.Roebbelen Headquarters

El Dorado Hills, CA

ABOUT ROEBBELEN

Page 3: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 3

MAJOR TELECOMMUNICATION COMPANY | CALIFORNIA, OREGON, AND WASHINGTON

Features:

• Blanket Contract • Contract Held Since 1998• $85 Million to $130 Million Annually• Over 1,100 Properties in Northern

California• Call Center• Mission Critical Facilities• Data Centers• Clean Rooms• Renovations/Tenant Improvements• Seismic Retrofits• Various Other Project Types

Owner:

John CarrilloDirector of Corporate Real Estate(925) 867-8985

Architect:

Various

Contract Information:

Delivery Method: CMARConstruction Type: VariousConstruction Value: VariousCompletion Date: Various

“The best example of their effectiveness I can provide would probably be that of a crew of 25 senior employees who use the building on a daily basis, not one has come to me with complaints on Roebbelen’s attitude, professionalism or work activities! Roebbelen employees go out of their way to make the building occupants feel comfortable with the procedures they undertake. I have talked to some of my peers that have had building renovations going on, and they can not make the same claims!”

~ Clay Berg, Project Manager, Major Telecommunication Company

Page 4: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 4

DATA CENTER | FAIRFIELD, CA

Features:

• 200,000 SF• Equipment Upgrades of the data

center which houses hundreds of server and data storage modules for mission critical operations as well as 411-information and customer information

• N+1 Redundancy Standby Power• Four 500 KVA UPS Modules• One 5,000 KVA Transformer• 1,500 kW Diesel Generator• 20,000 Gallon Above Ground Fuel

Tank• 700-ton chiller• 800 ton cooling tower

Owner:

Private Telecommunications Company2600 Camino RamonSan Ramon, CA

Contact: Brandon Harris, Area Manager(916) 972-4678

Project Site

North Watney WayFairfield, CA

Architect:

Lionakis1919 19th StreetSacramento, CA 95811

Contact: Chuck Hack(916) 558-1900

Contract Information:

Delivery Method: Design-BuildConstruction Type: UpgradeConstruction Value: $16,167,255Completion Date: February 2010

Page 5: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 5

PROJECT TRIGGER

The Fairfield Data Center houses hundreds of servers and data storage modules including customer account information, 911-emergency, 411-information and the company’s website. This building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring down the website or even interrupt 911 data and communications.

In the event of a commercial power failure, this building is supported by an N+1 redundancy standby power infrastructure. A recent building load study showed that the building load had exceeded their existing N+1 backup system capability. The continued increase in server quantity and building power needs, required an upgrade to the complete backup power system. In addition, as a result of the increased servers being placed on the data floors, more power circuits and cooling was needed to the data floor to support the growth.

TEMPORARY UPS PHASE

As an emergency temporary patch, Roebbelen installed two 550KVA UPS modules with fully enclosed batteries. These were tied into the appropriate switchgear and substations using temporary DLO cable. The DLO cable was run along solid cable racks installed over critical equipment, through fire-rated walls, through various rooms and corridors. All installed safely and quickly.

To cool the temporary UPS units, four 14,000 CFM Computer Room Air Conditioner (CRAC) Units were installed, with chilled water piping installed throughout the building to provide the proper cooling capacity for the UPS units.

The temporary UPS modules would be left in place to support the building before the permanent UPS upgrades were completed. Complete temporary UPS phase took two weeks working nights and weekends, to meet the deadline of having the systems operational.

Page 6: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 6

STANDBY SYSTEM UPGRADE

Two de-commissioned UPS units were shipped in from the Owner’s Florida Data Center. These units were fully refurbished and installed as permanent UPS modules in place of the temporary units. Two sets of 250 full wet cell batteries and racks were installed to accompany the refurbished UPS units. After testing and verification of load support and stability, the temporary UPS units and CRACs were taken offline.

New 1500kW diesel generator set, along with a new 20,000 gallon above ground fuel storage tank were installed to maintain the N+1 redundancy structure with the addition of the UPS modules and batteries. Existing fuel piping and fuel pumps were reconfigured for more efficient fuel delivery. New day-tank controls panels, transformer and all associated exhaust and ventilation for the new generator set were also provided.

In addition, four new 550 KVA UPS modules and 480 total wet cell batteries and racks were installed to assist the other UPS sets in load support. New full substation and static output switchgear lineups were installed for this new UPS string.

All electrical equipment was installed using detailed Method of Procedure steps, during off hours so as not to disrupt critical electrical systems. Coordination with on-site client building engineers was important in scheduling cutovers and tie-ins. Data Center rules dictated cutovers could only occur on certain weekends and times. This

Page 7: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 7

required constant updating of schedule to make the best and most efficient use of time.

To support this increase in heat load from all the new electrical equipment, new cooling system was implemented. It included a 700 ton chiller, 800 ton cooling tower (with Lakos filtration), and all associated chilled water lines and controls panels. In addition, three new air handlers, including new 40,000 CFM fan wall technology, were installed. Each AHU feeding air to an individual room.

DATA FLOOR GROWTH

Continued server additions and expansions required more power and cooling on 1st and 2nd floor raised-floor data floors. Power Distribution Units (PDUs) and Remote Power Panels (RPPs) were bolted throughout the data floors using earthquake bracing, and are ready for new servers and equipment to be connected. Twelve new CRAC cooling units and Variable Frequency Drives (VFDs) were also installed throughout the data floor in the warmest areas to prevent over-heating of this electrical equipment and provide efficient cooling.

The chilled water piping for the CRAC units and electrical feeds for PDUs, RPPs and CRACs were all installed underneath the raised floor of the data floors. Communication lines and other power feeders reside underneath the floor in a maze of cabling and supports. Any damage to the lines underneath the floors will cause critical loses in information and losses of millions of dollars to the clients and owners. Specific procedures were followed and tight coordination with on-site staff to ensure safe and efficient installation with no power or data interruptions.

Page 8: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 8

UPGRADING EXISTING SITE EqUIPMENT

• Parallel to the electrical and mechanical upgrades, the security card-reader access system was also upgraded to proximity sensor card readers. No security breaches occurred because of our vendor’s strong ability to communicate with the on-site staff of the installation phasing.

• Various existing outdated breakers, relays and panels were replaced. Various existing feeders, panels,

piping and motors were re-configured and re-labeled to better assist the on-site client staff in identifying sources of problems.

MISCELLANEOUS

Weekly project construction meetings were held by Roebbelen with all subcontractors, vendors and Owner’s personnel. The meetings were held every week for over two years. Minutes and action item lists were developed by the Roebbelen team.

Equipment list purchased and installed by Roebbelen and associated subcontractors:

• 700 Ton Chiller• 800 Ton Cooling Tower (with Lakos)• 1500 KW Diesel Generator Set• 12 PDUs (Power Distribution Units)• 32 RPPs (Redundant Power Panels)• 12 CRAC (Computer Room Air Conditioner) Units (12 VFDs)• 3 Air Handlers• (1) 5000 KVA Transformer• (4) 500 KVA UPS Modules (Uninterruptable Power Supply)• 980 Wet Battery Cells• (1) UPS Substation• (1) UPS Static Output Switchgear• (1) Motor Control Center (MCC-8)• (2) 1200 A Distribution Panels• (2) 400 A Switchboards• (3) ATS, 200A• (1) 20,000 Gallon AST

Page 9: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 9

VARIOUS PROJECTS | HAYWARD, CA

Features:

• Various infrastructure projects to maintain critical east bay data center

• Generator Replacements• Data Cable Mining• Redundant Cooling Systems• Raised Floor Installations• Power Upgrades

Owner:

Private Telecommunications Company2600 Camino RamonSan Ramon, CA

Contact: Syed Alim(925) 901-7104

Project Site

Winton AvenueHayward, CA

Architect:

Salas O’Brien305 South 11th StreetSan Jose, CA 95112

Contact: Carl Salas, Partner(408) 282-1500

Contract Information:

Delivery Method: Design-BuildConstruction Type: UpgradesConstruction Value: VariesCompletion Date: Continuous

Page 10: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 10

BLACKHAWK SWITCHING FACILITY | DANVILLE, CA

Features:

• 20,000 SF Building Addition• New and existing facility was pinned

down with caissons• Facility was protect by a 20 foot high

retaining wall featuring 150 caissons to stop soil movement

• New Generator System• Infrastructure Modifications• Fuel Storage• HVAC Upgrades• Construction completed while the

office stayed online throughout the project

Owner:

Private Telecommunications Company2600 Camino RamonSan Ramon, CA

Contact: Syed Alim(925) 901-7104

Project Site

Blackhawk Plaza CircleDanville, CA

Architect:

Lionakis1919 19th StreetSacramento, CA 95811

Contact: Chuck Hack(916) 558-1900

Contract Information:

Delivery Method: Design-BuildConstruction Type: UpgradesConstruction Value: $7,000,000Completion Date: July 2005

Page 11: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 11

ASI CALL CENTER AND DATA CENTER| DUBLIN, CA

Features:

• Three-Story Tenant Improvement Build-Out

• 150,000 SF• Raised Floor Through Out• 30,000 SF Data Center• 120,000 SF of Office Space• Two 1.5 mg Generators• UPS System• Fast Track Build Out - First 50,000 SF

Delivered Six Months from Design Inception

Owner:

Private Telecommunications Company2600 Camino RamonSan Ramon, CA

Contact: Farshad Arfaa(925) 823-8374

Project Site

Hacienda DriveDublin, CA

Architect:

Lionakis1919 19th StreetSacramento, CA 95811

Contact: Chuck Hack(916) 558-1900

Contract Information:

Delivery Method: Design-BuildConstruction Type: Tenant Improvements/

New ConstructionConstruction Value: $14,000,000Completion Date: June 2003

Page 12: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 12

DATA CENTER RETROFIT | PLEASANTON, CA

Features:

• 10,000 Total SF• 5,000 SF of Tenant Improvement• Multi-Phase Project• Mechanical System Upgrade• Electrical System Upgrade• Grow Equipment Space• Retrofit• Built on Raised Floor

Owner:

Private Telecommunications Company2600 Camino RamonSan Ramon, CA

Contact: Syed Alim(925) 901-7104

Project Site

Owens DrivePleasanton, CA

Architect:

Carter Burgess, Inc.300 Frank H. Ogawa Plaza, Suite 10Oakland, CA 94612

Contact: Gregory Mantz, Associate Principal(510) 457-0027

Contract Information:

Delivery Method: Design-BuildConstruction Type: UpgradesConstruction Value: $5,415,862Completion Date: January 2007

Page 13: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 13

WILLOWS TECHNICAL CENTER | REDMOND, WA

Features:

• 40,000 SF• Redundant Mechanical System• Redundant Electrical System• Grow Equipment Space• Seismic Retrofit• Built on a Raised Floor

Owner:

Private Telecommunications Company2600 Camino RamonSan Ramon, CA

Contact: Dale Tetzloff(925) 823-7844

Project Site

Redmond, WA

Architect:

KDW Architects & Engineers10202 5th Avenue NE, Suite 102Seattle, WA 98125

Contact: Arnold Kraakmo(206) 547-1940

Contract Information:

Delivery Method: Design-BuildConstruction Type: UpgradeConstruction Value: VariesCompletion Date: Continuous

Page 14: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 14

UNIVERSITY OF CALIFORNIA SAN FRANCISCO | SAN FRANCISCO, CA

Features:

• Consolidation of Multiple IT and Server Closets

• Initial Size is 7,900 SF with Space to Allow Growth to 11,000 SF

• 400kVA UPS System• 750kW Engine Generator• Redundancy of N + 1• Date Center and Tape Library are

Protected by a FM-200 Suppression System

• Certified LEED-CI

Owner:

The Regents of the University of CaliforniaSan Francisco, CA 94103

Contact: Craig Peterson, Associate Director(415) 353-3874

Architect:

Lionakis101 New Montgomery StreetSan Francisco, CA 94105

Contact: Scott Brady, Senior Architect(415) 777-4811

Contract Information:

Delivery Method: Design-BuildConstruction Type: ImprovementsConstruction Value: $4,563,590Completion Date: March 2009

“Over the weekend the University shut down their campus data systems to allow for the transition from the Parnassus Campus to the Data Center that you built. It went off without a hitch and we are currently up and running! This wasn’t the easiest project, but you all were a consistently professional team that I’m proud to have worked with. Success only comes from a team. Thank you all for a job well done!”

~ Craig Peterson, AIA, Associate Director, UCSF Capital Programs

Page 15: MISSION CRITICAL FACILITIESThis building is mission critical, with high ranking officials of the highest security levels overseeing operations. Power or cooling failures would bring

MISSION CRITICAL FACILITIES - PAGE 15

FACILITY BUILDING ADDITION | WALNUT CREEK, CA

Features:

• 52,033 SF• New Telecommunications Switching

Facility• Mission Critical Facility• Redundant Power Systems• Dry and Wet Fire Suppression System• Advanced Mechanical, Data and

Electrical Components

Owner:

Private Telecommunications Company645 East Plumb Lane, Room A114Reno, NV 89502

Contact: Vicki Howard, Senior Project Manager(775) 333-4382

Project Site

1755 Locust StreetWalnut Creek, CA 94598

Architect:

Lionakis1919 19th StreetSacramento, CA 95811

Contact: Chuck Hack(916) 558-1900

Contract Information:

Delivery Method: Design-BuildConstruction Type: Building AdditionConstruction Value: $13,155,837Completion Date: July 2007