  • 1/X.XX

    ABBREVIATIONS

    PR O

    JE C

    T N

    O .:

    20 06

    1 IS

    SU E

    D AT

    E: 0

    6/ 17

    /2 02

    0

    DRAFTING CONVENTIONS CONCRETE MASONRY (PLAN)

    CONCRETE MASONRY (SECTION)

    BRICK

    CONCRETE

    PRECAST CONCRETE

    STONE

    STEEL

    GYPSUM BOARD

    PLYWOOD OR COMPOSITE WOOD

    RIGID BOARD INSULATION

    BATT OR LOOSE INSULATION

    FINISH WOOD

    SOUND INSULATED PARTITION

    1 HOUR RATED PARTITION

    2 HOUR RATED PARTITION

    CENTERLINE / COLUMN LINE

    SMOKE RESISTANT WALLSSS SS

    GRAPHICS SYMBOLS 101 DOOR NO. DESIGNATION

    XX

    W1

    1 1

    1 1

    1 1

    1 1

    REVISION MARKER

    WINDOW DESIGNATION

    DETAIL OR SECTION NO. SHEET DRAWN ON

    INTERIOR ELEVATION NO.

    SHEET DRAWN ON SECTION NO.

    SHEET DRAWN ON EXTERIOR ELEVATION

    ENLARGED AREA

    INTERIOR PARTITION TYPE

    GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL ON-SITE DIMENSIONS.

    2. DIMENSIONS ARE REFERENCED TO FACE OF NEW INTERIOR STUD WALLS, COLUMN CENTERLINES & TO THE FACE OF EXTERIOR WALLS UNLESS OTHERWISE INDICATED.

    3. PROVIDE PRESSURE TREATED WOOD FOR CONCEALED MEMBERS IN CONTACTED WITH MASONRY OR CONCRETE.

    4. PROVIDE WOOD BLOCKING IN WALLS FOR THE SUPPORT OF EQUIPMENT, RAILINGS, ACCESSORIES, DRAPERY TRACKS, RECESSED ITEMS, ETC. AS REQD. HANDRAILS, GRAB BARS AND WALL MOUNTED TOILET FIXTURES ARE TO BE INSTALLED TO WITHSTAND A MIN. VERT. OR HORIZ. FORCE OF 250 LBS.

    5. MAINTAIN THE INTEGRITY OF RATED WALLS AT ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS & ALL RECESSED EQUIPMENT.

    6. CONTRACTOR SHALL VERIFY AND COORDINATE ROUTING, PLACEMENT, SPACE & CLEARANCE REQUIREMENTS FOR MECHANICAL, ELECTRICAL, & OTHER TRADES, REFERENCE PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS.

    7. UNLESS THIS PROJECT IS BEING BID, THE INTENT OF THESE DRAWINGS IS TO BE PART OF A "DESIGN BUILD" PROJECT. ALTHOUGH THE ARCHITECT HAS ATTEMPTED TO SHOW ALL CONSTRUCTION, THE ARCHITECT AND CONTRACTOR ARE TO COORDINATE ANY AREAS NOT NOTED ON THESE DRAWINGS. ANY ADDITIONAL INFORMATION REQUIRED WILL BE PROVIDED DURING CONSTRUCTION.

    8. TENANT GC IS REQUIRED TO HAVE A PRE CONSTRUCTION MEETING WITH LANDLORD REPRESENTATIVE PRIOR TO THE START OF CONSTRUCTION. ALL PAPERWORK MUST BE PROVIDED AT THE TIME OF THE PRE CONSTRUCTION MEETING, WITH THE EXCEPTION OF THE COI WHICH MUST BE PRESENTED PRIOR TO THE MEETING.

    PLANS REVIEW DATA MIDLOTHIAN, VA GOVERNING CODES & GUIDELINES

    STATEMENT OF INTENT GEORGE ARMOUR EWART, ARCHITECT HAS, TO THE BEST OF ITS PROFESSIONAL EFFORTS, DESIGNED AND PRODUCED THESE DRAWINGS TO COMPLY WITH ALL LOCAL, STATE, AND FEDERAL CODES APPLICABLE TO THIS PROJECT ON THE DAY OF ISSUANCE, WITHOUT BEING SUBJECT TO JUDICIAL INTERPRETATION AND TO BEST OF OUR KNOWLEDGE, THESE DRAWINGS ARE ALSO IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT OF 2010 (ADA).

    EASYVET OWNER TOM SCHOENFELDER CONTACT: 865-816-4131

    PROJECT ADDRESS

    MIDLOTHIAN, VIRGINIA 23114 13909 MIDLOTHIAN TURNPIKE

    IBC: GROUP B, BUSINESS OCCUPANCY CLASSIFICATION

    ROOF CONSTRUCTION

    FLOOR AREA

    BUILDING CLASSIFICATION TYPE II-B, UNPROTECTED, SPRINKLERED, ONE-STORY

    0

    NUMBER OF STORIES: 1 MAX AREA ALLOWED: 23,000 S.F. PER FLR. TENANT AREA: 1,482 S.F.

    STRUCTURAL FRAME 0

    BEARING WALLS EXTERIOR: 0 INTERIOR: 0

    NON-BEARING WALLS & PARTITIONS EXTERIOR: 0 INTERIOR: 0

    FLOOR CONSTRUCTION 0

    INDEX TO DRAWINGS COVER SHEET

    SE T

    #:

    DRAWING LOG

    LOCATION MAP

    SHEET DRAWN ON

    SHEET DRAWN ON

    PROJECT NO.: 20061

    ISSUE DATE: 06/17/2020

    P1.1 WASTE, WATER & GASPLUMBING

    M1.1 FLOOR PLAN - HVACMECHANICAL

    E1.1 FLOOR PLAN - ELECTRICAL

    E1.2 LEGENDS AND SCHEDULES

    E1.3 DETAILS

    ELECTRICAL

    SITE

    1

    NEW TENANT FITOUT FOR

    MIDLOTHIAN, VIRGINIA

    GENERAL NOTES & PLANS REVIEW DATA

    OCCUPANT LOAD = 1482sqft/ 150 = 10 OCCUPANTS MAX

    ACOUSTICAL TILE ABOVE FINISH FLOOR ALTERNATE ALUMINUM BLOCKING BUILDING CABINET CERAMIC TILE CENTER TO CENTER CUBICLE CURTAIN TRACK CENTER LINE CORNER GUARD CLEAR CORRUGATED METAL PIPE CONCRETE BLOCK MASONRY UNIT COLUMN CONCRETE CARPET DOUBLE DRINKING FOUNTAIN DOOR FRAME GUARD DOWNSPOUT DRAPERY TRACK EXISTING CORNER GUARD ELEVATION ELECTRICAL PANEL ELECTRIC WATER COOLER EXPANSION JOINT EXISTING FINISH FLOOR FAN COIL UNIT FINISH FACE OF BRICK FACE OF MASONRY FACE OF STUD FACE TO FACE FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET GALVANIZED GRAB BAR GENERAL CONTRACTOR GROUND FAULT INTERRUPT GUARD POST GYPSUM BOARD HANDICAP HIGH PRESSURE DECORATIVE LAMINATE INSULATION INVERT (ELEVATION) JOINT MARBLE METAL NOT APPLICABLE NONE COMBUSTIBLE NOT IN CONTRACT NOMINAL ON CENTER OWNER FURNISHED, CONTRACTOR INSTALLED OPPOSITE HAND OUTSIDE TO OUTSIDE PLASTIC LAMINATE PARTIAL PLASTER PAINT PAPER TOWEL DISPENSER PATCH TO MATCH EXISTING PARTITION REFRIGERATOR REVISION SOAP DISPENSER SQUARE FEET SQUARE INCHES SHEET VINYL TONGUE AND GROOVE TOP OF STEEL TO MATCH EXISTING TOWEL BAR TACK BOARD TOILET PAPER HOLDER UNLESS NOTED OTHERWISE VINYL VINYL COMPOSITION TILE VERIFY IN FIELD WALL COVERING OR WATER CLOSET WOOD WALL GUARD

    ACT AFF ALT ALUM BLKG BLDG. CAB CT C/C CCT C/L or CL CG CLR CMP CMU COL. CONC. CPT DBL. DF DFG DS DT ECG ELEV. EP EWC EXP. JT. or EJ EXIST or EX FF. FCU FIN FOB FOM FOS F/F FD FE FEC FHC GALV. GB GC or GEN. CON GFI GP. GYP. BD. HC HPDL INSUL. INV. JT. MBL MTL. N/A NC NIC NOM OC OFCI OH or OPP HD OS/OS P. LAM or PL PART PLAST PT PTD PTME PTN REF. REV SD SF or SQ. FT SQ. IN SHV T&G TOS TME TWL TKBD TPH UNO V VCT VIF WC WD WG

    ARCHITECTURAL AS ARCHITECTURAL SPECIFICATIONS

    AD ACCESSIBLE DESIGN

    A1.1 FLOOR PLAN, CEILING PLAN, AND ENLARGED DETAILS

    A3.1 SCHEDULES AND DETAILS

    A3.2 INTERIOR SIGNAGE DETAILS

    A8.1 INTERIOR ELEVATIONS

    CONSULTANTS PLUMBING, MECHANICAL & FIRE PROTECTION ENGINEERS

    ELECTRICAL ENGINEER

    3107 SUTHERLAND AVE.

    865-637-4451 KNOXVILLE, TN 37919

    VREELAND ENGINEERS

    500 CLYDE STREET ALBERT BEDINGER CONSULTING ENGINEERS

    865-637-8339 KNOXVILLE, TN 37921

    2009 ACCESSIBLE BUILDINGS AND FACILITIES CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL FUEL GAS CODE 2010 FIRE SPRINKLER CODE 2011 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2012 VIRGINIA UNIFORM STATEWIDE BUILDING CODE

    LANDLORD CONTACT CHARTER (E&A), LLC

    1272 5TH STREET NE SCOTT SPENCER

    202-902-2679 WASHINGTON, DC 20002 SUITE 22

    06/17/2020

  • PROJECT MGR.:

    DATE: PROJECT NO.:

    AS

    N EW

    T EN

    AN T

    FI TO

    U T

    FO R

    M ID

    LO TH

    IA N

    , V A

    A R

    C H

    IT EC

    TU R

    A L

    SP EC

    IF IC

    AT IO

    NS

    20061 GAE

    06/17/2020

    06/17/2020

    WOOD CABINETS- LAMINATED FACE 1. AWI Quality Standard: Comply with applicable requirements of Architectural Woodwork Quality Standards and details as shown on drawings.

    BATT INSULATION FOR SOUND AND TEMPERATURE 1. See drawings for location, extent, dimensions and related data for sound and temperature batt insulation.

    FIRESTOPPING 1. Furnish and install firestopping materials and systems at openings and voids in, or at periphery of fire-rated construction as indicated on the drawing. All firestopping used on the project shall be from one manufacturer. Provide details and UL designs for all applications before commencing work.

    SEALANTS AND CAULKING A. Provide sealing and caulking of joints as shown on the drawings, including backing fillers where required. 1. Use caulking compound only on interior joints. 2. Use sealant compound for all joints exposed to the weather. 3. Submit manufacturer's material descriptions and instructions for each compound and filler along with standard color chart for approval.

    STEEL DOORS AND FRAMES Provide doors and frames complying with the Steel Door Institute. 1. Fire-rated assemblies a. Whenever a fire-resistance classification is shown or scheduled for steel doors and frames, provide fire-rated investigated and tested as fire door assembly, complete with type of hardware to be used. Identify each fire door and frame with recognized testing lab labels, indicating fire rating. b. Shop applied primer suitable as a base for finished painting. c. Fabricate exterior doors and frames from galvanized steel. d. Prepare hollow metal units to receive finish hardware in accordance with final finish hardware schedule. e. Flush metal doors shall be of seamless construction, with face sheets formed of 1 sheet of steel. Doors shall be 1 3/4" thick unless noted otherwise. Provide counter-sunk flat Phillips head for exposed screws or bolts. f. Interior doors- minimum 18 gage faces. g. Exterior doors- extra heavy duty, minimum 16 gauge faces with insulated core. Fabricated doors from galvanized steel, close top and bottom edges with a minimum 16 gage inverted steel channels. 2. Steel Frames a. Provide metal frames of the type and styles, indicated on the drawings. Where metal frames are indicated for wood doors, provide frame gauge as specified for steel doors. 16 gauge. b. Provide metal frames for doors, transoms, side lights, borrowed lights, and other openings as shown on drawings, concea