Microwave Planing Training Guide

111
HUAWEI TECHNOLOGIES CO., LTD . Huawei Confidential Security Level: Internal www.huawei.com Microwave planning (Using Pathlossv4) Training guide

Transcript of Microwave Planing Training Guide

Page 1: Microwave Planing Training Guide

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Security Level: Internal

Slide title :40-47pt

Slide subtitle :26-30pt

Color::white

Corporate Font :

FrutigerNext LT Medium

Font to be used by customers and

partners :

Arial

www.huawei.com

Microwave planning(Using Pathlossv4)

Training guide

Page 2: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

pathloss preparations_map

What is the SRTM?

SRTM (Shuttle Radar Topography Mission) is a type of digital map. SRTM obtained elevation data on a near-global scale to generate the most complete high-resolution digital topographic database of Earth.

How to get it?

There are 2 methods: ftp://e0srp01u.ecs.nasa.gov/srtm

Use the download manager to help you in download

you can get it from that link: http://www.freedownloadmanager.org/

The best way to select the region you want to download files for it:

We can use that site http://cartographic.com/.to select the area we need to download

Page 3: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

pathloss preparations_map

To upload the SRTM files for pathloss:

Choose Configure----Terrain database you will find the shown screen

From primary menu choose SRTM-ASTER

Page 4: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

pathloss preparations_map

After that click on the button setup primary you will find the shown page

From file menu choose BIL-SRTM HGT,ASTER TIF

You will find your pc browse your pc for the SRTM files and upload them to the pathloss

Page 5: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

pathloss preparations_coordinates

Coordinate appears in two common formats: 1-Decimal Format like 12.345678 N 2-Degree minutes second Format like 13 05 20.80 N How to convert from the second type to decimal format ? To convert the above second type to decimal we do the following: 13+(05/60)+(20.80/3600) which equal 13.089111111 in Decimal

Page 6: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Microwave planning stages

Microwave planning consists of three main stages:

1-Entering link coordinates and generating the link profile and then determine antenna heights.

2-Creating the worksheet for the link according to the customer KPI or Huawei KPI

3-Making Frequency interference calculations

Page 7: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

How to enter coordinates to pathloss

1-we can entering coordinates for sites needs to be planned from the excel sheet for it as follows:-

first open the coordinates excel sheet and save it as CSV(comma delimited) file as the shown

Open the pathloss and press Ctrl+N

Or you can choose module----Network

In network page choose site data----site list ,you can find the site list screen

Page 8: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First stage_ Sites input

Press import and then site text file you will find that table

Put the colum number of the sites name in the excel sheet beside site name in the pathloss table(column no 1 in our example

Repeat that for latitude and longitude column no(col2 for long and 3 for latitude

Then press import button from pathloss table

and attach your saved comma delimited file for coordinates

then press ok you will have the pathloss screen for sites names and coordinates

Page 9: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First Stage_Network

Close the previous menu you will findthe map for all the sites in the excel sheet as you can see here you can connect the sites together by clicking the NE and drag

to the other site

Connect all sites together according to the plan

Page 10: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First stage_Terrain data

we will start configure link by link

Left click by mouse on the first link and choose(Terrain Data) the shown screen will appear

Choose operation-----Generate profile

The pathloss will draw the link terrain data between the two sites

Page 11: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First stage_Terrain data

You can add any obstacle you got from the survey by double clicking on the structure column you will find the shown

You can choose single structure or range of structures according to your obstacle

For example if you have range of structures after you click range you will get the shown menu

So you can modify the height for your obstacle , the start and end of the obstacle range in KM

Page 12: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First stage_Antenna height

After that you can choose Module-----Antenna height

Before you calculate the minimum height for LOS you have to calculate minimum K as follows:

From antenna height page choose operation---minimum k you will find the shown page so you can find the minimum K included in it

Page 13: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First stage_Antenna height

After that choose operation-----clearance criteria you will find the shown page put the frequency you use in the bottom of the table

Add the minimum K you got from previous slide to second K criteria in the table

Adjust all other values as shown Press ok after that you can

calculate the minimum height for the antenna

In general links less than 20 km the minimum K can be taken as 0.67 without calculations

so you can click on the calculator symbol to get the minimum height needs for line of sight and you click to change the heights of the antenna

Page 14: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First stage_Print profile

After that you can choose module-----print profile to confirm that the lowest fresnel zone is above the highest obstacle as the shown profile

As we can see in the figure there are three layers for the earth the top one is for minimum k and when we go down layer by layer the K factor becomes larger till we reach infinity at the earth surface

Page 15: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First Stage_K factor values

For the Regular(K factor):

If K=4/3 the fresnel zone f1 should be more than 100%(for main antenna)

If Kmin=2/3, f1 should be more than 60% (for main antenna)

If K=4/3 the fresnel zone f1 should be more than 60%(for SD antenna)

If Kmin=2/3, f1 should be more than 30% (for SD antenna)

Page 16: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First Stage_Diffraction

Diffraction calculations From Module menu Choose Diffraction You will find the shown page From configure menu choose Edit

K list from the shown menu add the Value for Minimum K you got before

Page 17: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First Stage_Diffraction

From the bottom tool bar double click on TR-TR you will find the shown menu

You have three choices in that menu to calculate:

1-Diffraction for the main antenna

2-Diffraction for the two SD antennas in both sites of the link

Page 18: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First Stage_Diffraction

Choose the first choice and click ok

After that click on the Calculator symbol to calculate the value of the Diffraction for the main antenna you can find the shown menu

IF the value of the diffraction Loss is Zero so it is ok no Diffraction

If there is value so you have to raise the antenna to decrease that value to zero

Repeat the above for the two SD antenna and Raise the SD antennas if needed to make the Diffraction loss equal Zero

Page 19: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

First Stage_Reflection

Adjusting Reflection loss We have to decrease the Reflection loss

to be less than 10ns Choose Module ------- Reflection then

choose Define Plane you will find the shown page

Make right click then left click and right click again on the start of the profile in the previous page then do that again at the end of the profile to calculate the reflection for all the path you will find the shown page

The delay should be less than 10 ns If it is more than 10ns we have to

change antenna height till we adjust it Also we if the previous way did not

adjust the reflection we have to add SD antenna to adjust the reflection

Page 20: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Worksheet

Creating the work sheet: 1-Choose Module----Work sheet You will find the worksheet page as

you can see below:

A-First left click on the rain icon and choose rain area according to maps of rain using ITU 7/8 also choose the link polarization vertical or horizontal

Page 21: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage(Rain Map)

Page 22: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_dn/dh calculations(Reliability Method ITU-R P.530-7/8)

B-(in case of ReliabilityITU-R P.530-7/8 )Then choose the Geoclim factor dn/dh by checking the four maps one by one to take the worst month value from the four maps and write it in the page seen below.

Also from print profile you can know the height for the terrain for the link(elevation) to choose the suitable option from the menu as that affect the availability

Put the field margin to 1db it is a margin for installation team

Page 23: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Example for one of the four maps for Gradient factor(dn/dh)February map

Page 24: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_How to Check the dn/dh maps

We search in that map by the coordinate for the link As the horizontal axe indicates east and west The vertical axe indicates north and south So for example if we check the coordinate 13 05 20.80 N and 029 27 33.73 E means we will take 27 in the right hand of the

middle zero on the horizontal axe and intersect it with 13 above the middle zero on the vertical axe so we can find the point for our dn/dh from that map which is a number

We should repeat that for the other three maps(May-August-November) and choose the worst value(the biggest one)

We do the same way to choose the Rain area from the rain map using link coordinate but here there is only one map

The value here is a letter means : Rain area C (like Egypt) or Area E(like Sudan)

Page 25: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Equipment selection

Choose the equipment as you can see here

-From code index you can get the equipment folder from your PC.

3-Huawei has five IDUs for RTN900: IF1 for TDM traffic IFU2 for hybrid traffic(IP and TDM) IFX2 for hybrid and support XPIC ISU2 for package traffic ISX2 for package traffic and

support XPIC

Page 26: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_ODU selection

After you choose the IDU type you will find each IDU support three types of ODU:

1-HP

2-SP

3-SPA

4-XMC1

5-XMC2

Page 27: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Antenna selection

You can choose the antenna by left click on it and choose antenna folder from your pc

We change the antenna diameter according to customer KPI(to achieve the KPI)

.

Page 28: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_KPI WITH ITU-R P530-7/8

Customer KPI( in case we use reliability method ITU-R P.530-7/8) are:

Example for KPI in this case: 1-Availability(most of time it needs

to be 99.999 for rain and multipath and the total one

2-Fadmargin should be more than or equal to 30db for PDH and more than or equal to 35db in SDH

3-May be customer ask for specific received signal

Page 29: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_ KPI FOR KQ S(1.3)

In case we use Reliability method KQ S (1.3) the worksheet result will be as shown.

Example for KPI in this case: 1-the WORST MONTH SESR

should be less than 10^-6 and so the seconds/month should less than 20 seconds

The Fade Margin should be more than 30db in PDH and more than 35 db in SDH

The Minutes /Year should less than 3 minutes in PDH and less than 0.5 minute in SDH

Page 30: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Roughness factor calculations

In that case when we use Reliability method KQ.S(1.3) we do not need the dn/dh here we need to define the Roughness Factor as follows:

From the worksheet double click on the path between the two sites you will have the shown menu

Page 31: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Roughness factor calculations

Choose Rough from the previous menu you will have the shown page

(from laptop)Click home button+f1 then click end button+f1 you will find that the program counted the Roughness factor for that link which indicates the terrain height for the link

That Factor affect the SESR for the link as for links have high Roughness it has good SESR

Page 32: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_KQ factor calculations

After calculating the Roughness factor from the previous page we should Calculate the KQ factor to complete filling for the same menu of the Roughness factor

To calculate the KQ factor use the shown table and by choosing the suitable choice from the shown four according to your area

We only take the value beside the Character S which indicates the KQ value and we put it in the pathloss

For example for the first choice the KQ factor is 4.1E-5 we enter it only like that to pathloss and the same for the other three choices

Page 33: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_KQ factor calculations

From the previous table you should take the values for B and C which exist at the top of the table and put it at pathloss

We put that two values at the Reliability menu in the shown marked two boxes the KQ Frequency exponent take the b value and the KQ Distance exponent take the c value

Page 34: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second Stage_losses calculations

All types of losses should be included in the work sheet:

Connector loss should be 0.5 db for each site as shown

we add the waveguide loss in Txline loss above the connector loss as the shown here

Page 35: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second Stage_losses calculations

Waveguide loss we add that loss when the ODU not directed connected to the antenna so we

add it when we use single polarization separate or dual polarization antenna and it is different according to frequency band we use as shown

You can find the tables of Waveguide losses for different Vendors as follows:

single polarization separate is used when the frequency is 6G or the antenna diameter is bigger than 1.8m

Andrew losses RFS losses

Page 36: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

Coupler loss

When we use HSB protection for( 1+1 )system one of the coupler side has 1.7 db loss and the other side is 6.7 db loss so we add 1.7 for each site as we consider the working ODU

Page 37: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

IF we use NEC 5000S Long haul system the branching losses should be as shown for 64 QAM,the losses shown for each case for both sites of the link so we divide it for each site

We use that table in case of ACAP(Adjacent channel Alter polarization) which means we use different polarization for adjacent channels if channel 1 is vertical so channels2 should be horizontal

Also please note that when we have system 1+3 for example so we consider it as one sys (1+1) and another sys 2+0 so we take the losses for 2+0 from the shown table and we do that for all cases take the high protection to choose the losses value

Also for 1+3 Freq Channels here can be for example ch1,ch2,ch3,ch4 or ch1,ch3,ch4,ch5

ITEM4GHZ5GHZU6GHZ8GHZ11GHZGURANTEED

BR CKT Loss *2, *3

(Circulator type)

1+0 (dB)4.75.35.46.58+1db

1+1 (dB)5.15.75.878.3+1db

1+2 (dB)5.56.16.27.58.6+1db

1+3 (dB)5.86.56.688.9+1db

1+4 (dB)9.19.2+1db

1+5 (dB)9.5+1db

Page 38: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

NEC 5000S branching circuit losses for 128 QAM

Also all cases here are the same as the above page ITEM4GHZ5GHZL6GHZU6GHZ7GHZ8GHZ

GURANTEED

BR CKT Loss *2, *3

(Circulator type)

1+0 (dB)5.25.95.46.46.46.8+1db

1+1 (dB)5.66.35.8777.3+1db

1+2 (dB)66.76.37.57.57.8+1db

1+3 (dB)6.37.16.6888.3+1db

1+4 (dB)6.88.29.19.19.4+1db

Page 39: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

That case when we use continuous channels(1,2,3,4) or uncontinuous channels ,also polarization here should be the same for all channels

The above table for 64 QAM

The lower one for 128 QAM

when the system configuration is less than 3+1, the loss for 5000s takes the loss of 3+1. When the system configuration is 4+1 to 6+1, the loss for 5000s takes the loss of 7+1.

ITEM4GHZ5GHZU6GHZ8GHZ11GHZGURANTEED

BR CKT Loss *2, *3

(Circulator type)

1+3 (dB)6+1db

1+7 (dB)7.3+1db

ITEM4GHZ5GHZL6GHZ7GHZ8GHZGURANTEED

BR CKT Loss *2, *3

(Circulator type)

1+3 (dB)6+1db

1+7 (dB)7.3+1db

Page 40: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

For Adjacent channel co polarization(same polarization for the adjacent channels like ch1 and ch2) channels here must be continuous(1,2,3,4) only

For 64 QAM we have only one case we can use it which is (1+3) with 4GHZ Frequency Band and the losses here is 8.2

And for 128 QAM there are two cases with the protection (1+3) one of them with 7GHZ has losses 9.1 and the other case with 8GHZ with losses 9.5 as shown in below table

ITEM4GHZ5GHZL6GHZU6GHZ7GHZ8GHZGURANTEED

BR CKT Loss *2, *3(Circulator type)

1+3 (dB)9.19.5+1db

ITEM4GHZ5GHZU6GHZ8GHZ11GHZGURANTEEDBR CKT Loss *2, *3(Circulator type)

1+3 (dB)8.2+1db

Page 41: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

For 5000s using XPIC we use CCDP(co channel duplex polarization) which means we use two polarization for the same channel

So in the XPIC case if we have 2(2+1) for example that means we will take the losses for (2+1) system

when the ACCP system configuration is less than 3+1 in the table, for example 2+1, the loss for 5000s is the same as the one of 3+1.

Page 42: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_5000s frequency

For the 5000S the frequency should be as the attached file

if 5000s is used, the frequency assignment must follow the table

5000s frequency tables

Page 43: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

We add that losses to pathloss as shown here 7 GHZ(1+2) system

Also we add the same branching losses for the SD Antenna

Page 44: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

Feeder Loss When we use NEC 5000s we need

to add the loss of the feeder which changes according to:

Feeder length we add 15 meter to the height of the antenna when we calculate feeder length(or according to the distance between the tower and the 5000s equipment we can add the suitable length margin to the feeder)

Also the feeder losses changes with the type of the feeder and the frequency band

As you can see we add the feeder type and its total length also we add its loss/100m and so the pathloss gives you the total losses for that feeder

Page 45: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_losses

For the loss of Elliptical Waveguide which used for 5000s is as the attached:

From the above attached word file we can know how to use the other attached file for calculating the Eliptical Waveguide loss for 5000s

Andrew_ewg.txl

Guide.doc

Page 46: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_XPIC

If we use XPIC ,IFX or ISX should be used.

We got the shown menu from operation menu we choose co-channel XPD interference

For the shown Menu we have to check that the values for the following three fields are automatically applied

If not applied we have to apply them For the XPIF value:

the XPIF value for RTN 900 according to that table

For RTN600 only 128 QAM with 28M so all XPIF IS 17.

For 5000S all XPIF is 19 For the Antenna, we check the

XPD value for the antenna which is 30 to 40 db according to the antenna type

Page 47: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_XPIC

We also open operation then reliability methods and then we check the checkbox co-channel operation as shown

Page 48: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage

How to add SD antenna From the worksheet choose

Configure-----antenna configuration You will find the shown menu Choose the second option TRDR-

TRDR Press ok button you will find there

is SD antenna added to the worksheet

You can go to the antenna height page and configure the SD Antenna height

Also from the worksheet you can choose the type of the SD Antenna

Page 49: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_SD Antenna

When we need to use SD Antenna and at what Height we can put it? We use SD antenna to improve the SESR and the availability for the multipath

and so to improve the link performance SD does not affect the Fade margin SD antenna should receive max signal at the minimum signal for the main

Antenna and vice versa

Page 50: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_SD Antenna

How to determine the height of the SD Antenna? The height of the SD Antenna should be choosed to improve the SESR or the

Availability of the link Also we have to choose the height of the SD to achieve Max signal at the Main

Antenna minimum signal and vice versa(for that we adjust the auto correlation from pathloss)

Also we have to check the Diffraction for the SD height to ensure no Diffraction

The optimum Separation between the Main and SD antenna for ideal auto correlation is 8meter

But when every time we increase the separation between Main and SD the performance ,The SESR value and the availability improve

So we have to match all the above items to determine SD Antenna Height

Page 51: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_SD Antenna

Adjusting Auto correlation between Main And SD Antennas:

First Define the reflection as we saw before from Define plane menu

After that we adjust the Roughness from module menu we choose Reflection

From Reflection page choose modify and from that menu choose Roughness you will got the above shown Page calculate Roughness as we saw before

Also from Reflection page from Variable menu choose Earth Radius factor as shown in the below picture

Page 52: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_SD Antenna

You will find the shown menu Adjust the start earth radius

factor(k) to 1.33 The End Earth radius factor to 3 Click on microwave antenna

combination Button you will find the three option menu shown

Choose the first(TR-TR) option and click ok

You will find that site 1 antenna height and site2 antenna height adjusted automatically to the values in the antenna height sheet

Page 53: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_SD Antenna

Click ok in the shown menu the pathloss will give you the curve for the received signal for the main antenna

Repeat the above for the other two options(TR-DR) and(DR-TR) in the three option menu

You will find the another two curves for the two SD Antennas for the link

Page 54: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_SD Antenna

Change the SD or the main antenna heights in both sites till you reach the max for the two SD curves at the minimum for the main Antenna curve and vice versa as shown

When you change the antenna heights you have also to check the link performance and the Diffraction cause all that factors should be ok at the same time

Page 55: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Worksheet Report

You can output the report by left click on Report--------Full Report and make print for it

Page 56: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_System Configurations

System configuration cases: 1-(1+1) HSB 2- 2(1+1) HSB 3- 2(1+1) HSB with XPIC 4- (1+1) SD 5- 2(1+1) SD 6- 2(1+1) SD with XPIC 7- (1+1) FD 8- (2+1) FD 9- (3+1) FD 10- (4+0) FD

We have to check the below configuration before we make the worksheet to determine exactly what is our losses and how we can put our frequency channels.

Page 57: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 1+1 HSB Protection for the IFH2 of the IDU 620

The IDU 620 supports one to two 1+1 HSB protection groups. One 1+1 HSB protection group uses

one channel and consists of the following items:

Two ODUs that are of the same type

One hybrid coupler: The hybrid coupler can be balanced or unbalanced. Generally, the unbalanced

hybrid coupler is used.

One antenna

One Freq channel with one polarization

Page 57

f1

f1

H

Page 58: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 2 (1+1) HSB Protection for the IFH2 of the IDU 620

Using Four ODUs of the same type

Two coupler(balanced or unbalanced) of the same type

But we prefer to use unbalance coupler cause it is lower losses

two freq channel with two different polarization

One antenna Dual polarization

f1

f1

f2

f2

H

V

Page 59: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 2 (1+1) HSB Protection using XPIC for the IFH2 of the IDU 620

Using Four ODUs of the same type

Two coupler(balanced or unbalanced) of the same type

But we prefer to use balance coupler cause it is lower losses

one freq channel with two different polarization

One antenna Dual polarization with high XPD

H

V

f1

f1

f1

f1

Page 60: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 1+1 SD Protection for the IFH2 of the IDU 620

The IDU 620 supports one to two 1+1 SD protection groups. One 1+1 SD protection group uses one

channel and consists of the following items:

Two ODUs that are of the same type

Two antennas

Same Freq channel and same polarization

Page 60

f1

f1

H

H

Page 61: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 2(1+1) SD Protection for the IFH2 of the IDU 620

Four ODU of the same type

Two antenna

Two frequency channels with different polarization

H

H

V

V

f1

f1

f2

f2

Page 62: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 2(1+1) SD Protection using XPIC for the IFH2 of the IDU 620

Four ODU of the same type

Two dual polarization antenna with high XPD

One frequency channel with two polarization

f1

f1

f1

f1

H

H

V

V

Page 63: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 1+1 FD Protection for the IFH2 of the IDU 620

The IDU 620 supports one to two 1+1 FD protection groups. One 1+1 FD protection group uses two

channels and consists of the following items:

Two ODUs: The two ODUs should work on different frequency channel .The other information about

the two ODUs, however, must be consistent.

One single polarization antenna (with one balanced hybrid coupler), as shown in the figure in the

upper left corner with two freq channels(not adjacent channels)

Or One dual polarization antenna with two different freq channel (can be adjacent)

Page 63

f1

f3

H

f1

f2

H

V

Page 64: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 2+1 FD Protection for the IFH2 of the IDU 620

three ODU of the same type cause we use the same Frequency band

One balanced coupler(no unbalance)

One dual polarization antenna as the above figure

Or two single polarization antenna as the below figure(not recommended for hardware and tower space)

three frequency channels the adjacent channels can not be the same polarization (distributed as shown)

f1

f3

f2

f1

f3

f2

H

H

V

V

Page 65: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 3+1 FD Protection for the IFH2 of the IDU 620

Four ODU of the same type cause we use the same Frequency band

Two balanced coupler(no unbalance)

One dual polarization antenna as the above figure

Or two single polarization antenna as the below figure(not recommended for hardware and tower space)

Four frequency channels(not adjacent for the same polarization) distributed as shown

f1

f3

f2

f4

f4

f2

f1

f3

H

H

V

V

Page 66: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Hardware Configuration of the 4+0 FD for the IFH2 of the IDU 620

Four ODU of the same type cause we use the same Frequency band

Two balanced coupler(no unbalance)

One dual polarization antenna as the above figure

Or two single polarization antenna as the below figure(not recommended for hardware and tower space)

Four frequency channels(not adjacent for the same polarization) distributed as shown

H

H

V

V

f1

f3

f2

f4

f1

f3

f2

f4

Page 67: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

Repeaters: We use repeaters when there is a problem in line of sight or the link distance is

very big so we can not achieve our KPI so we need intermediate site to connect our target two sites(target link)

We have two kinds of repeaters: 1-Active repeaters 2-passive repeaters

Page 68: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

Active repeaters:

We use that kind of repeaters when the distance between the two sites of the link which has a problem in LOS is big distance so we prefer to use that kind of repeaters cause we use complete site (use all antennas and equipment as normal site)so we achieve good performance

That type is not preferred for the cost cause we build complete site In that case we get the coordinate for the Repeater site from the Google Earth

program then make normal links as shown in the above pages

Page 69: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

Passive Repeaters:

There are three types of passive repeaters but we use only one type which is(Back To Back Antenna)

In this type we don’t need to make any indoors or equipment for the repeaters just the Antennas and make Back to Back connecton between both directions of the Repeater

That type is preferred to make cost reduction But for long distance we will need more repeaters(Max no of repeaters is

3(three) So in the links have big distance we do not use that type

Page 70: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

How to make passive repeater using Pathloss:

First you have to add the coordinate of end sites and the repeater sites. We should make the path profile for all links(links between the repeaters sites

and the end sites) Make all diffraction and reflection calculations using minimum K Add the equipment as we did before for the end sites and may be also for the

repeaters For the repeater site you should use the same detail for that site for all its

directions

Page 71: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

Creating the back to back passive repeater:

Open the worksheet for one of the links related to the repeater

Choose operation then create passive repeater

Page 72: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

You will find the shown menu which contains passive repeaters types

Choose back to back antenna You will find your PC browse your

PC for the PL4 file for the second passive link

Repeat that if you have more than one repeater

Page 73: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

Click on the passive icon on the work sheet(P)

You will find the shown passive data menu

The passive gain of back to back antenna calculated as the sum of antenna gains minus the transmission line and connector loss

Page 74: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

The vertical angle is shown for reference only

If the antenna data is added when the individual link profile are created the data will be transferred to the previous page data entry menu

Page 75: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

How to make Repeaters using Google Earth program: First we have to enter the sites needs Repeater to Google earth using Huawei

tool which manage us to upload large no of sites in fast and easy way to Google Earth program

You have to change all coordinates to Decimal Format to upload it to that Form

Page 76: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

Open the Excel sheet for that tool and enter the project Name in the most left side of the sheet

After that paste all the coordinates to that sheet

Mark all that column Choose Macro and Then choose

Run For that Macro You will find the KML file for all

that sites saved automatically at the C partition for your PC

Open the Google earth program and upload that KML file

coordinates upload

Page 77: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

To add new site(Repeater site to Google Earth)

Choose the yellow icon from the top tool bar which indicates(Add Place mark)

Page 78: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Second stage_Repeaters

After choosing the previous icon you will find the shown Menu opened

Also you will find new icon for the new site appear

Drag that new icon and drop it to the place you want to put it on

Try to put the new Repeater at the minimum distance from the two sites needs to be connected cause that is better for links performance

From the shown menu you can put the name for that new Repeater

Also take the coordinate for that Repeater and add it to the Pathloss

After that start to make design for the repeater with the existing sites using Pathloss

Page 79: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Principles of selecting proper frequency bands: 1. Select proper frequency bands according to the frequency resources

(licenses) owned by the carriers and the stipulations of local radio management committees.

2. Select proper frequency bands according to the characteristics of the designed networks and routes. For example, high-frequency bands are generally used for mobile networks.

3. Select proper frequency bands according to their characteristics.

• Low-frequency bands (L6G/U6G/7G/8G/11G) are suitable for long-distance links and high-frequency bands (13G/15G/18G/23G/26G/38G) are suitable for short-distance links.

Page 80: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

• Due to the limited number of channels existing at low-frequency bands, interference tends to arise in the long-distance transmission.

• High-frequency bands are suitable for high-speed data transmission and interference sustainable because there are many channels with broad bandwidth.

• High-frequency antennas feature high gains. Compared with low-frequency bands, high-frequency bands require small clearance. Towers with these antennas properly used can be lower than others

Page 81: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Division of microwave frequency bands:

FrequencyShift Frequencies (MHz) (T-R Spacing) Use

4-7 GHz161, 154, 245 Long-distance network

backbones

8 GHz126, 161, 154. 199, 266, 311Long-distance network

backbones

11-13 GHz266Short and medium distance

15 GHz308, 420, 490, 315. 720, 728Short and medium distance

18 GHz340, 1092.5, 1008, 1010, 1560Short and medium distance

23 GHz600, 1050, 1232, 1008, 1200, Short distance in urban areas

26 GHz855, 1008Short distance in urban areas

28 GHz1008Short distance in urban areas

32 GHz812Short distance in urban areas

38 GHz700, 1260Short distance in urban areas

Page 82: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Principles of selecting proper microwave channels:

1. Try not to select the special frequency resources (licensed) used by other carriers even if these frequency bands are not used in some areas (in case they may be used in the future).

2. If the planned microwave link features the same routing or parallel routing as another microwave link, it is recommended that the frequency band/channels different from those of the existing link are used. A different polarization mode should be configured even if the same channel is adopted as a result of the little interference and big margin proved by the calculation and analysis.

Page 83: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Principles of selecting proper microwave channels:

3. If the angle between two interleaving routes is comparatively small (for example, smaller than 30 degrees), a different channel should be selected. If the angle is quite large (for example, larger than 60 degrees), the same channel can be used provided a different polarization mode is configured. The same channel with the same polarization mode can be used only when the angle is larger than 90 degrees. This is a generally adopted principle for microwave frequency planning. For different equipment, antenna configuration, or capacity, analysis should be made on the link accordingly.

4. In the design, the microwave link should be as far from the scatter communication station and the satellite communications earth station as possible. When the antenna of the microwave station is directed to the satellite orbit with a tolerance of ±2 degrees, the frequency band of the communication satellite cannot be used.

Page 84: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Example for the microwave frequency planning:

In frequency planning, reusing of frequency resources should be taken into account, the internal and external interference should be avoided,

and the link quality should be enhanced .Polarization should alternate every other hop for the decrease of overreach interference. The polarization configured alternate every hop is

conducive to the decrease of front-back interference upon the antenna .

1H 1H1V

1V

2H

1H

Overreach interference

Front-b

ack inte

rfere

nce

Third stage(interference calculations)

Page 85: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Two-frequency system and quadruple-frequency

system used in microwave frequency planning:

For the 1+1 system or 2+0 system of the frequency diversity, the use of the two-frequency system can save the frequency resources, while the use of the quadruple-frequency system can decrease the internal and external interference and enhance the link quality. Whether to select the two-frequency system or the quadruple-frequency system depends on the interference within the planned microwave network system and the mutual interference between the microwave links to be established and the links

existing in the system .

Case 1: When the link to be established interleaves with an existing one, the two-frequency system can be used for the former provided the same system is used for the existing link, and a different channel should be selected in this case.

Existing link

Link to be established

1,3

1,32,4

2,4

Page 86: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Two-frequency system and quadruple-frequency system used

in microwave frequency planning:

Case 2: When the link to be established interleaves with an

existing one, the quadruple-frequency system can be used for

the former provided the same system is used for the existing link.

In this case, the neighboring links(with small angles) should

have different channels .

Existing link

Link to be established1,3

2,42,4

1,3

Case 3: When the link to be established has a branch, the quadruple-frequency system should also be used for this

branch .

1,3

2,4

1,3

Page 87: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Two-frequency system and quadruple-frequency

system used in microwave frequency planning:

Case 4: When the link to be established forms a loop-line with quite small angles, the quadruple-

frequency system should be selected. 1,3

2,42,4

Case 5: When the routing deflection angles are too great, but the angles of

La and Lb are quite small, for example, smaller than 15 degrees,

comparatively great overreach interference may occur if the two-

frequency system is selected for Site A and Site D. Therefore, the

quadruple-frequency system should also be used in this case.

1,3

1,3 1,3AB

C

D

2,4La

Lb

Page 88: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Add the frequency for each channel and its polarization and channel ID and mention which site high and which low from the worksheet as you can see below

Repeat that link by link for all links of the project

When you choose frequency channels do not use the same channel for two links have separation angle less than or equal to 90 degree

If you need to repeat the freq channel do that for angles more than 90 degree

Page 89: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

from module choose network you can find the map for all the links

Choose configure------directories----microwave radio you can find your pc menu choose the location where you save the code file for the radio equipment you use for that project

Repeat that to choose the place of antenna folder you use for the project

Page 90: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Choose interference-----calculate interference you will find the below menu

you can use the configuration for that menu as you can see here

Then click calculate to start calculate interference

Page 91: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

In the previous menu: 1-choosing coordination distance=200 km that means the program will

calculate all interference comes from all distances till 200 km distance. so if we need to calculate interference from the same channel and same

bandwidth we should put the Maximum freq separation=0 but if the bandwidth is different we take the biggest bandwidth as a separation so if we have 7MHZ,14MHZ,28MHZ we can put it 28 MHZ or any no more than 28

Interference comes from the adjacent channel can be neglected as we always take adjacent channels with different polarization

3-Default minimum interference level =-115 means we will count all interference values not less than that level

4-Thereshold Degradation=1 Means all cases have T.D more than one will be displayed in the interference report

Page 92: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Choose interference-----reports-----hi lo violation as you can see below

you will find the report for all links high and low violation status

at any site all site should be high or should be low if one site contains some directions high and some low(has violation) you should check that report and fix all links violation after that recalculate interference again and check the violation to confirm it is ok.

Page 93: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Also check the error log it should have no errors

Page 94: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Choose interference-----reports-----cross reference

Page 95: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

You can find the report for interference contains the cases of interference exist

Compare each case T.D(threshold degradation) with the thereshold degradation for customer KPI

All interference cases should have T.D less than or equal to the customer KPI T.D

Page 96: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

If the exist interference case T.D is bigger than the customer KPI T.D

Try to change polarization between the same channels for the two links have interference or try to change between channels for the same band between the two infected links

Sometimes you need change the whole frequency band for the two infected links

Also when we open ATPC interference decreases

Page 97: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Sometimes we found that there are some interference cases that have T.D more than the required KPI and when we try to change polarization we can not fix it and may be we have no more frequency channels to change

For that cases we can open the interference report for that case from pathloss and we check that two links which have problems together

To check which site from the two links affect on which site After that we can try to make direct link between that two sites and check the

Line Of Site May be we find that to achieve LOS between that two sites needs very high

towers(may 200 meter in each site) means to achieve loss we need height more than the maximum tower heights for our project

So that case not actual case cause the signal can not be transmitted Between the two sites cause there is no LOS between them

Page 98: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

If you add one new link and you want to calculate interference only for that link with all other links in the network do the following:

From the network page left click on that link and open the worksheet for that link

After that return to the network page again

Choose interference then activate the checkbox which mention:

Analyze(link name) only Then press calculate

Page 99: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

After every change you have to recalculate interference again

And check the cross reference report

Or from the same menu you can choose case detail to give all details about interference case by case

Page 100: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage(interference calculations)

Make interference Report from cross reference page

Choose file----Save as RTF File

Page 101: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage_Frequency division

How to Assign Frequency channels:

The frequency channel we assigned to the link should have the same bandwidth with our microwave equipment

If we use Freq channel has 28MHZ bandwidth we should use equipment 28MHZ bandwidth

Also if the frequency channel has 28MHZ bandwidth ,we can use equipment 14MHZ but that not preferred as we waste the frequency resources so if the customer gives channels have big bandwidth we can divide it to smaller bandwidth channels

But we can not use equipment has 28MHZ bandwidth with frequency channel has 14MHZ bandwidth

Page 102: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage_Frequency division

How to divide frequency channels: EXAMPLE If we have the following four channels with bandwidth 55 MHZ and we need to

divide them to 27.5MHZ channels

18GHz

Ch.NoupperlowerBand WidthShifter

11

1931518305551010

121937018360551010

131942518415551010

141948018470551010

Page 103: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage_Frequency division

We will take the first channel lower frequency which

is18305 and the last channel lower frequency which is 18470 For 18305 is the center freq so the range for that center is from 18305 –(55/2) to

18305+(55/2) Also for the last channel the Range is from 18470-(55/2) to 18470+(55/2) So our range for the new 27.5 MHZ divided channels will be from 18305-

(55/2 )to 18470+(55/2) means

From 18277.5 to18497.5

Page 104: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Third stage_Frequency division

We can take the above Frequency range and search at the frequency channels table using the frequency band which is 18GHZ and the shifter which 1010 and the bandwidth which is 27.5 MHZ and choose all Freq channels located inside our freq range which is:

From 18277.5 to18497.5 we will find the following channels:

Ch.NoupperlowerBand WidthShifter

22193151830527.51010

2319342.518332.527.51010

24193701836027.51010

2519397.518387.527.51010

26194251841527.51010

2719452.518442.527.51010

28194801847027.51010

Page 105: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

How to assign the ODUsubband FOR EACH FREQUENCY CHANNEL

For example we can take the first channel in the table which is: 18305 lower and 19315 upper with bandwidth 27.5 MHZ and shifter 1010 We take the lower freq 18305 which is the center freq for that channel which is

from 18305-(27.5/2) to 18305+(27.5/2) means from 18291.25 to 18318.75 and we check from the ODU SUBBAND TABLE

Page 106: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

How to assign the ODUsubband FOR EACH FREQUENCY CHANNEL

We insert the frequency band which is 18GHZ and the shifter which is 1010 and click on the button on the ODU subband sheet it will give us all channels for that band and shifter as shown:

And so we can find our channel in Subband C

Also we can find that for our channel the ODU can be one of the following :

1-HP(high power)

2-SP(standard power)

3-SPA or LP or LPA

18 GHzALo1768517985HP 、 SP、 SPA 、LPA 、 LP

18GHzAHi1869518995HP 、 SP、 SPA 、LPA 、 LP

18GHzBLo1793018230HP 、 SP、 SPA 、LPA 、 LP

18GHzBHi1894019240HP 、 SP、 SPA 、LPA 、 LP

18GHzCLo1818018480HP 、 SP、 SPA 、LPA 、 LP

18GHzCHi1919019490HP 、 SP、 SPA 、LPA 、 LP

18GHzDLo1840018700HP 、 SP、 SPA 、LPA 、 LP

18GHzDHi1941019710HP 、 SP、 SPA 、LPA 、 LP

odu subband

Page 107: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

How to make the final Report for all links of the Network

From Network page choose Site data then site list you will get the shown screen

From the previous screen choose Report then CSV link list-Microwave, you will get the shown screen

From the left side of the shown menu you can choose the factors you want to appear in the links report and add that factors by arrows to the right side of that menu to appear at your report

Then press OK you will get the report page

From the report page choose file then save the report to your PC

Page 108: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

How to make the final Report for all links of the Network

The below fields should be included for the final report:

Operator code

Site 1

Name

Site 2

Name

Site 1

Call Sign

Site 2

Call Sign

Site 1

Latitude

Site 2

Latitude

Site 1

Longitude

Site 2

Longitude

Path length

Site 1

Azimuth

Site 2

Azimuth

Site 1

Antenna (Main)

Site 1

Antenna (SD)

Site 2

Antenna (Main)

Site 2

Antenna (SD)

Site 1 TX power

(dBm)

Site 2

TX power

(dBm)

Site 1

Radio

Code

Index

Site 2

Radio

Code

Index

Site 1

RX signal

(dBm)

Site 2

RX signal

(dBm)

Site 1

SES (wm

-sec)

Site 2

SES (wm

-sec)

Site 1

UN (min/yea

r)

Site 2

UN (min/yea

r)

Site 1

Fade

margin

(dB)

Site 2

Fade

margin

(dB)

Site 1 Ch ID

Site 2 Ch ID

Site 1 TX Freq (MHz)

Site 2 TX Freq (MHz)

Site 1

Polarization

Site 2

Polarization

Page 109: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

How to make the bill of quantity(BOQ) for the project

The BOQ should be as below and we output it for RTN product during the biding project as the attached sheet:

Also the BOQ for 5000S as the below attached file:

RTN BOQ

5000S BOQ

Page 110: Microwave Planing Training Guide

Slide title :32-35pt Color: R153 G0 B0

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

Slide text :20-22ptBullets level 2-5:

18pt Color:Black

Corporate Font: FrutigerNext LT Medium

Font to be used by customers and

partners : Arial

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Needed tools for planning work

Pathloss version4 Odu subband tool which indicates the odu subband for each frequency

channel Google earth program to find the place and coordinates for repeaters and also

to check the places of sites Frequency band tables which gives the channels for all frequency bands and

shifts Maps for Rain and the gradient four maps Equipment folder and antennas folder needed for making worksheet

Losses table for waveguide(included in this slide) XPIF table(included in this slide) 5000s losses table (included in this slide) The power point slides for both RTN600 and RTN900 to indicate which

equipment we can use as it indicates bandwidth for all equipments

Page 111: Microwave Planing Training Guide

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Security Level: Internal

Slide title :40-47pt

Slide subtitle :26-30pt

Color::white

Corporate Font :

FrutigerNext LT Medium

Font to be used by customers and

partners :

Arial

www.huawei.com

Thank you