MICROSOL 15 MM - ricardo.ro · MICROSOL 15 MM Microsol 15 mm 2/2 & 3/2 - way valves DIMENSIONS 1...
Transcript of MICROSOL 15 MM - ricardo.ro · MICROSOL 15 MM Microsol 15 mm 2/2 & 3/2 - way valves DIMENSIONS 1...
2
1 3
MICROSOL 15 MMMicrosol & Microsol Interface 15 mm 2/2 & 3/2 - way valves
Very compact design
High flow rate
For lubricated and unlubricatedcompressed air, neutral liquidsor gases
High cycle rate of up to 2000cycles per minute
Long life - in excess of 100million cycles*
* Hit & Hold valves:10 million cycles
Flange mounted
TECHNICAL DATASolenoid valve for air, andneutral liquids or gases
Operation:
Microsol: Poppet valve, directlyactuated with spring return
Microsol interface: pilot operatedpoppet valve, servo assisted
Switching function:
Normally closed and normally open
Response time:
8 - 10 ms
Operating pressure:
0 - 10 bar
Fluid temperature:
-10°C ... +30°C
Ambient temperature:
-10°C ... +50°C
Mounting position:
As required
MATERIALSBody: for 2/2 valves PPS, for 3/2valves PPS, PA, Stainless steel
Seat seal: NBR
Internal parts: Stainless steel, PA 6/6
NC Flange 1,1 27 0 - 10 Push only No 24V DC 2,0 4 01-311P1011H0+61111+AYZ
NO Flange 1,1 27 0 - 6 No No 24V DC 2,0 4 01-321P1011H0+631A1+AYZ
Actuation Function Port Hit & Hold* Voltage Power(W)
MODELS
2/2 Direct acting valves
NC Flange 1,1 48 0 - 10 No No 24V DC 2,0 1 01-211P202-H0+63111+AYZ
NO Flange 1,1 48 0 - 10 No No 24V DC 2,0 2 01-221P202-H0+631A1+AYZ
2
1 3
3/2 Direct acting valves
2
12
1
www.norgren.com/info/en3-166
For further information
3-166
* PWM energy saving option
Standard conformity: IINERIS 00ATEX0031 X
Orificemm
Flowl/min
Operatingpressurebar
Manualoverride
Drawingno.
Voltage tolerance -10 % / +15 %
Rating 100% E.D.
Electrical insulation 1500V AC
Insulation class F (155°C)
ELECTRICAL DETAILS
3-167
ACCESSORIES
Single connector M/P43082
Single connector LED+VDR 24V M/P43086
Single connector LED+VDR 110V M/P43148
Single connector LED+VDR 220V M/P43087
Single connector and 1 m flying lead M/P43066
Electrical connector
Symbol Function Port Orificemm
Flowl/min
Hit & hold* Voltage Power(W)
Drawingno.
MODELS
* PWM energy saving option. ***Standard conformity: IINERIS 00ATEX0031 X
NC Flange 3,0 194 1,5 - 10 Push only No 24V DC 1,0 6 01-312E-06-HP+A1171+AYV
NO Flange 3,0 194 1,5 - 10 No No 24V DC 2,0 6 01-322E-06-HP+C31G1+AYZ
NC Flange 3,6 194 0 - 6 No Yes 24V DC 12 / 0,5 3 01-211P-036H0+63111+AZN
NC Flange 0,5 8 0 - 7 Push only No 12V AC/DC 0,55 5 01-311P-00-H0+F01003+BCC
NC Flange 0,5 8 0 - 7 Push only No 24V AC/DC 0,7 5 01-311P-00-H0+F01003+BDH
NC Flange 0,5 8 4 - 7 Push only No 12V DC 0,1 5 01-311P-00-H0+H01014+AWD
NC Flange 0,5 8 4 - 7 Push only No 24V DC 0,1 5 01-311P-00-H0+H01016+AYG
NC Flange 0,8 18 0 - 10 Push only No 12V DC 1,5 4 01-311P101-H0+61511i+AWM
NC Flange 0,8 18 0 - 10 Push only No 24V DC 1,5 4 01-311P101-H0+61511i+AYS
NC Flange 0,8 18 0 - 10 Push only No 24V AC 1 4 01-311P101-H0+11511i+AXX
NC Flange 0,8 18 0 - 10 Push only No 48V AC 1 4 01-311P101-H0+11511i+BAU
NC Flange 0,8 18 0 - 10 Push only No 110V AC 1 4 01-311P101-H0+11511i+BBJ
NC Flange 0,8 18 0 - 10 Push only No 220V AC 1 4 01-311P101-H0+11511i+BCK
3/2 Interface valves / high flow models2
1 32
1 3
3/2 Direct acting valves / intrinsically safe (IS) models***
2/2 Direct acting valves / high flow models
2
1
2
1 3
3/2 Direct acting valves / other options as used on M54 range**
2
1 3
Operatingpressurebar
Manualoverride
MICROSOL 15 MMMicrosol 15 mm 2/2 & 3/2 - way valves
DIMENSIONS
1 Wire (red) / pin +
2 Wire (black) / pin –
3 Manual override
4 For NC models
5 For NO models
6 Mounting pattern
7 The recommended mounting
screw tightening torque is 0,6 Nm.
Index
All solenoids are supplied with mounting screws and gasket.
Warning for Hit and Hold valves: damage could be caused to the valve if wired incorrectly.
41
AM
P 2
,8x0
,5
9,4
M 3
x3
9,7
8,2
3
15,2
20,7 7,4
14,2
3,8 17,2
M 3
1
3
7
2
3
A
2
1
1,9
3,8
3,8
A
6
48
AM
P 2
,8 x
0,5
9,4
M 3
x 3
9,7
6,9
2,2
4 6
3,3
3,3
14,2
17,2
M 3
3,8
15,2
20,7 2
1
7,4
1 2
A
A
7
6
3-168
41
AM
P 2
,8 x
0,5
14,2
17,2
15,2
20,7
9,7
8,2
7,4
A
A
9,4
M 3
M 3
x 3
2,2 3,
83
2
1
1 2
7
6
3,8
46,2
AM
P 2
,8 x
0,5
14,2
17,2
15,2
20,7
9,7
8,2
7,4
A
A
9,4
M 3
M 3
x 3
2,2 3,
83
2
1
1 2
3,87
6
1 2
4 3
Description
46,2
AM
P 2
,8 x
0,5
9,4M
3 x
3
9,7
8,211
3
15,2
20,7 7,4
14,2
3,8 17,2
M 3
1
3
2
3
A
2
1
1,9
3,8
3,8
A
647
41,5
22 6,5
54M3
x 25
AMP 2,8x0,5
32,5
15,2
9,7
18
3,1(3x)
55
9,7
1,4
ø 3,1+ 0,1
M3
-
7,41
23
3
6
4
5
7
M3
9,4
21
15 M3
3,5
24,5
1 23,5
25
Pg7 ø14
3 35
4,7
15,5
+0,
1
15,5 +0,1
3
9,4+0,1 -
Electrical connector*
3-169
5 6