Micro DCIM - ZHUHAI PILOT TECHNOLOGY CO.,LTDen.pmac.com.cn/images/download/20160607udvuky.pdf ·...

4
Data Centre Infrastructure Management Micro DCIM • Built-in WEB server to achieve HTTP access • B/S structure, Graph dashboard with multi function • Support various equipment connect & monitoring; • Powerful remote alarm function (SMS, E-mail) • Comprehensive environment monitoring; • Utility energy analysis and report function; • History events and data storage • Multiple users authority management; • Standard connection terminal (RJ45,RJ11,DB9); • Support on-line upgrade; • Build-in backup battery for 6 hours off-power. • UPS and Battery Bank (By UPS card & PBAT) • Precision Air Condition (By PAC smart card) • Power Distribution Panel (By Power meter) • Intelligent PDU/RPP (By BCPM meter) • Generator Monitoring (By Genset controller) • Environment Monitor by Sensors: - Temperature & Humility, - Water Leakage ( Located or Unlocated) - Smoke, Door Status, Infrared Sensor • Linkable to Network Access Control System • Linkable to CCTV System Pilot ® Micro DCIM is a comprehensive monitoring, alarm and management system for equipment status, environmental condition and power & space usage in telecom room and small data centre. As a convenient visible and reliable tool, it helps IT-room maintenance team to see infrastructure condition and get alarm in time. Enterprise Server Room Building Data Centre Module Data Centre Container Data Centre Suit for Medium and Small-size Data Centre Web View Remote Alarm Local Monitoring http://en.pmac.com.cn General Feature Applicable for Easy Cabling What We Can Monitoring:

Transcript of Micro DCIM - ZHUHAI PILOT TECHNOLOGY CO.,LTDen.pmac.com.cn/images/download/20160607udvuky.pdf ·...

Data Centre Infrastructure ManagementMicro DCIM

• Built-in WEB server to achieve HTTP access• B/S structure, Graph dashboard with multi function• Support various equipment connect & monitoring;• Powerful remote alarm function (SMS, E-mail)• Comprehensive environment monitoring;• Utility energy analysis and report function;• History events and data storage• Multiple users authority management;• Standard connection terminal (RJ45,RJ11,DB9);• Support on-line upgrade;• Build-in backup battery for 6 hours off-power.

• UPS and Battery Bank (By UPS card & PBAT)• Precision Air Condition (By PAC smart card)• Power Distribution Panel (By Power meter)• Intelligent PDU/RPP (By BCPM meter)• Generator Monitoring (By Genset controller)• Environment Monitor by Sensors: - Temperature & Humility, - Water Leakage ( Located or Unlocated) - Smoke, Door Status, Infrared Sensor• Linkable to Network Access Control System• Linkable to CCTV System

Pilot® Micro DCIM is a comprehensive monitoring, alarm and management system for equipment status, environmental condition and power & space usage in telecom room and small data centre. As a convenient visible and reliable tool, it helps IT-room maintenance team to see infrastructure condition and get alarm in time.

• Enterprise Server Room• Building Data Centre • Module Data Centre • Container Data Centre※ Suit for Medium and Small-size Data Centre

• Web View• Remote Alarm• Local Monitoring

http://en.pmac.com.cn

General

Feature

Applicable for

Easy Cabling

What We Can Monitoring:

Func

tion

& C

onne

ctio

n

E-m

ail

Net

wor

k R

oute

rN

etw

ork

Li-io

n B

atte

ryM

ax 6

hour

bac

kup

tim

e,

repl

acea

ble

Sour

ce A

Sour

ce B

LCD(

Fron

t)

Dis

play

IP &

GSM

32G

SD

Card

For

2~4

year

s re

cord

s st

orag

e

Dua

l Pow

er S

uppl

y +

Dua

l Eth

erne

t Por

t A

vaila

ble

to c

onne

ct w

ith tw

o di

ffere

nt p

ower

sup

ply,

red

uce

risk

of

pow

er-o

ff al

arm

dis

able

. Tw

o E

ther

net p

ort,

redu

ndan

cy c

onfig

urat

ion,

rea

lize

phys

ical

laye

r of

in

tern

al a

nd e

xter

nal n

etw

ork,

enh

ance

link

relia

bilit

y

8 R

J45

data

ext

end

port

for

Smar

t dev

ice

with

RS4

85 c

omm

unic

atio

nE

xten

dabl

e M

ax. 2

4 te

mpe

ratu

re &

hum

idity

det

ecto

r, 2

loca

tion

wat

er le

akag

e de

tect

ors,

8

dist

ribut

ion

switc

h de

tect

ors

(eac

h ca

n co

nnec

t 8 s

witc

h de

tect

ors,

tota

l 64

switc

h de

tect

ors)

, 4 a

ir-co

nditi

onin

g co

ntro

llers

, 2 g

ener

ator

s, 4

gen

eral

pow

er d

istri

butio

ns (o

r 2 g

ener

al p

ower

met

er a

nd 2

IP

DU

’s B

CP

M)

Gen

eral

air-

cond

ition

ing

mon

itor

Dis

trib

utio

n sw

itch

dete

ctor

Loca

tion

wat

er

leak

age

dete

ctor

Tem

pera

ture

&

hum

idit y

det

ecto

r

BC

PM

PD

U /

RPP

Po

wer

Met

erG

ener

ator

Stan

dard

ized

inte

rface

for c

orre

spon

ding

dev

ice

2 x

DB

9 an

d 2x

RJ4

5 po

rt fo

r RS

485

com

mun

icat

ion

for

prec

isio

n ai

r-con

ditio

ning

& U

PS

Prec

isio

n U

PSai

r-co

nditi

onin

g

4 Al

arm

Rel

ay O

utpu

t Ter

min

al

Cho

ose

suita

ble

alar

m m

etho

d,

relia

ble

and

easy

to re

aliz

e un

atte

nded

. So

und-

light

Al

arm

Tele

phon

e Vo

ice

USB

con

nect

Bui

ld-in

GSM

Mod

em fo

r al

arm

mes

sage

-PB

AT

Bat

tery

Mon

itor

Syst

em

•Li

nk e

xter

nal m

onito

r sy

stem

by

Ethe

rnet

Non

-loca

tion

wat

er le

akag

ede

tect

or

Switc

hde

tect

orSP

Dsw

itch

dete

ctor

Smok

ese

nsor

Doo

rse

nsor

Infr

ared

mod

ule

-Net

wor

k Ac

cess

con

trol

sys

tem

-CC

TV M

onito

r sys

tem

8 R

J11

port

for

dry

cont

act c

onne

ctio

n8

dry

cont

acts

, ava

ilabl

e fo

r non

-loca

tion

wat

er le

akag

e,

SP

D s

witc

h de

tect

or, L

imite

d cu

rrent

sw

itch

dete

ctor

, in

frare

d in

trusi

on d

etec

tors

, doo

r sen

sor,

smok

e se

nsor

et

c. d

ry c

onta

ct d

evic

e, p

rote

ct y

our

serv

er ro

om s

afet

y

1U d

esig

nfo

r 19

’ rac

k

US

BP

ower

242m

m

480m

m

45.5

mm

Mic

ro D

CIM

http://en.pmac.com.cn

Micro DCIM-Data Centre Infrastructure Management

Interface and Dashboard

Technical information

Home Page Environment Sensor Air Condition Monitoring

UPS Monitoring Power Distribution Monitoring Map Mode Display

Power Usage Analysis Historical Record Capacity Management

CPU 32-bit ARM high-speed centre processor Flash RAM 1G byte NAND Flash

Build-in GSM Quad-band GSM, 1 x SIM card slot Data storage: 32G, 1 x SD card slot

Ethernet Port: Dual – Ethernet Port, High-speed, self-adaptive. Default IP address: IP1 ( 192.168.0.100 ) , IP2 ( 192.168.1.100 )

Signal input Port:Series Port

2 x RS232 ( DB9 port )• Max 4 UPS or Precision Air-conditioning

2 x RJ45 port ( RS232 / RS485 multiplex port )

8 x RJ45 port ( RS485 )• Max 16 ~ 24 units remote temperature• Power meter, Location Water leakage

detector and other smart device

Status input 8 x RJ11 ports: (dry contact status input) 0 ~ 5V TTL

Alarm output Port: Relay output 4 Channel, Wiring Terminal 12VDC / 1A

Other Port: USB 2 @ Front

Support Protocols: TCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP, ICMP, HTTPS, IPV6, PPP, etc.Modbus_RTU, Modbus_TCP

Other configuration: Real time system clock;Remote configuration and update Power Switch: ON / OFF Switch

LED Indicator: Power, Status, Ready, LAN10/100M Link / Active Front Display LCD

Power Supply Dual Power Supply: 110V-240V(60HZ/50HZ), IEC connector Backup battery: 2 ~ 6 hours

Environment: Working Temperature: 0℃~55℃ Humidity: 10~80%

Dimension: 1U, 480 x 242 x 45.5mm ( L x W x H ) Safety Certificate: CE

Add: No. 15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong, China Post Code: 519085 Tel: +86 756 3626166/3639029Fax: +86 756 3629600/ 3629700 Email: [email protected] http://en.pmac.com.cn

Micro DCIM-Data Centre Infrastructure Management

Your representative

PILOT reserves the right to modify features without prior notice in view of continued improvemen

Order Information

Optional Monitor Kits

Optional Alarm Kits

ZHUHAI PILOT TECHNOLOGY CO., LTD.PILOT (HENGQIN)CO.,LTD

Main Module Name Edition Functional difference

- V1

( Basic Edition)• Temperature & Humidity : Max 16 Units

- V2

( Advanced )

• Temperature & Humidity : Max 24 Units• Support Diesel Generator Monitor• Support Branch Circuit Power Meter• Support PBAT Battery Monitor• Support Location Water Leakage Detector

Item Monitor Kits Part Num. Function Connection

1 UPS Monitor Card / Modbus monitor card for UPSAccording to UPS type and brand RS232

1Three Phase Power Meter PMAC770

SPM33Power & Energy Monitor for Power Panel

Three phase, with THD, PFRJ45

(Modbus_RTU)

Single Phase Energy Meter SPM91 Power & Energy Monitor for Power PanelSingle phase, Max 63Amp

RJ45 (Modbus_RTU)

2 Temperature & Humidity Sensor PM77007OLCD display

Monitor temperature and humidity of server room(Every 20 M² need to install 1 sensor)

RJ45 (Modbus_RTU)

3 Smoke Sensor PM77143 Detect the data centre smoke status(Every 20 M²-30M²need to install 1pc of sensor)

RJ11 (Dry Connect)

4 Infrared Detector PM77145 Detect intrusion area by infrared RJ11(Dry Connect)

5 Door Contact Sensor PM77431Monitor the on-off status of door/window,

take up 1 switch quantity portRJ11

(Dry Connect)

6Non-location Water Leakage Detector

PM77109 Non-location water leakage cableWork with detector cable, Max 500m cable

RJ11(Dry Connect)

7 Branch Circuit Power Meter (Advanced) PMAC202 Power & Energy Monitor for Power Panel Max 42 branch circuit

RJ45 (Modbus_RTU)

8Location Water Leakage Detector (Advanced)

PM77800 Location Water leakage detectorWork with detector cable

RJ45 (Modbus_RTU)

9 PBAT Battery Monitor (Advanced) PBAT Series Monitor backup battery bank of UPS RJ45

(Ethernet)

Item Alarm Kits Part Num. Function Connection

1 Sound Light Alarm Module PM77410 For Sound light alarm, take up 1relay output DO (Relay terminal)

2 Voice Dialing Alarm PM77422 Telephone voice alarm, USB access & Power supply USB

MicroDCIM

USB Power

242mm

480mm

45.5mm

Micro DCIM