Micro Control Solutions Stability System II rev. 6.4 Click for next slide Move to the next slide...
-
Upload
bobby-provins -
Category
Documents
-
view
219 -
download
0
Transcript of Micro Control Solutions Stability System II rev. 6.4 Click for next slide Move to the next slide...
Micro Control SolutionsStability System II rev. 6.4
““Click” for next slideClick” for next slidewww.microcontrolsolutions.com
Move to the next slide when the request appears
Interactive Modular Design
““Click” for next slideClick” for next slide
• displayed alert for sample pull• displayed alert for testing initiation• displayed alert for testing completion
• click on an alert to see the samples in the category
www.microcontrolsolutions.com
• use the “Quick Call” function for instant study access
• scan a bar code or enter the study ID # to initiate the function
www.microcontrolsolutions.com
Admin. Level Application Settings
21CFR Part 11• application lockout timing
• separate setting for data• application logoff timing• password confirmation request for edits• define access attempts• define login display• define password aging cycle• define inventory pull alert and email• define test initiation alert and email• define test completion alert and email• define data approval levels
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
• individually assign a user’s application access or...• assign them to one of 5 custom designed user groups
Admin. Level User Access Settings
21CFR Part 11
““Click” for next slideClick” for next slide
• define applications and default locations for documents that can be “attached” to individual studies for instant recall.
www.microcontrolsolutions.com
Admin. Level Application Settings
Multi-level audit logs• application event logs
• application access logs
• study and specification library edit logs
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Library and Dictionary Templates
• product templates• tests• limits• precision• # of entries• laboratory preference• alert & variance limits• test library selection option
““Click” for next slideClick” for next slide
• define multiple testing matrixesdefine multiple testing matrixes
• define default inventory requests define default inventory requests by intervalby interval
www.microcontrolsolutions.com
System Dictionaries“point and click entry”
• packaging components• fills • containers• closures• liners• seals• resins• manufacturers• more...
• study conditions
• reason for study
• storage location
• mfg. and packaging sites
as typical examples...
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Initiate a Study“point and click entry”
• select your product template
• enter study information using “point and click” dictionary options or type in required information
• company unique information can be added using “user defined” database fields
• track the manufacturer and lot # for the API or any other ingredients
• enter study environment information using dictionary options or type in required information• standard or user defined interval options, both auto-calculated
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Initiate a StudyInventory and labels
• set inventory by selecting default option or manually enter
• make controlled label requests per interval• max equal to requested inventory• all labels numbered x of y by interval• label field content is user defined• bar code enabled
• select the label size• define up to 4 default label formats• label color option available
““Click” for next slideClick” for next slide
• use the label manager to generate all use the label manager to generate all requested labels labels
www.microcontrolsolutions.com
Initiate a StudyDocument Attachment
• attach external documents to the study• study protocol• methods• OOS or OOT documentation• investigation reports• chromatography reports• PDF, Word®, or Excel® documents among others
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Schedule Samples
• schedule samples• “quick month” option• entered time frame
• schedule options• print/preview• print forms• filter by criteria• add to laboratory pending list
• pending list options• print/preview• filter by criteria
• un-pulled samples• testing cycle• products• advanced query
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Bar Code Inventory Functions• update inventory
• scanner can be detached and taken to the chamber• scan sample labels or entry on “inventory bar code” report
• open inventory options• options for bar code or manual reduction• update by date• take “extra”• restore inventory
• bar code step 1• date of the pull• pulled by
• bar code step 2• reattach the scanner and all scanned samples will be downloaded and automatically updated• or you can scan each bar code individually while attached to the computer
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Bar Code Testing Cycle Functions
• update testing initiation/completion• scanner can be detached and taken to the laboratory• scan sample labels or reporting forms
• open testing cycle options• select initiation or completion• options for bar code or manual entry
• test initiation/completion• reattach the scanner and all scanned samples will be downloaded and automatically updated• you can scan each bar code individually while attached to the computer• or manually update
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Bar Code Integration• bar codes contain the study ID and test interval
• based on the function requested the requisite section of the bar code is activated• use the “Quick Call” function to activate a study from the main menu
• scan the bar code on a bottle or reporting form to enter results for a study at the designated test interval listed in the bar code
• scan the bar code on a bottle, reporting form, or other report to:
• generate a summary report• recall a study to edit• generate charts and evaluations• initiate any function that requests the entry of the study ID
• scan the bar code on a summary report to:• recall the study in edit mode• generate charts and evaluations• generate a C of A for a test interval• initiate any function that requests the entry of the study ID
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Data Handling and Review
• scan the bar code on a bottle or reporting form to enter results
• enter results for each required test• out of spec results highlighted in red• out of alert results highlighted in blue• compare to previously approved results• add interval comments
• multi-level configurable approval process• view interval summary• data approval locks all editing functions• compare the current results to previously approved results
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Reporting Functions• multiple reporting optionsmultiple reporting options
• summary reportssummary reports• define the report contentdefine the report content• “ “data only” for each testdata only” for each test• “ “data/dates” for each testdata/dates” for each test• “ “data/dates/references” for data/dates/references” for each testeach test• define the report layoutdefine the report layout• list tests for “individual results”list tests for “individual results”• define print orderdefine print order• add/remove tests from the add/remove tests from the reportreport• use the bar code to activate use the bar code to activate any functionality for the studyany functionality for the study• highlight out of spec data if highlight out of spec data if desireddesired• print:print:• formsforms• tablestables• logslogs• labelslabels
• graphics reportsgraphics reports• single study single study • sample to samplesample to sample• expiration single studyexpiration single study• expiration multiple studiesexpiration multiple studies• data export functiondata export function
““Click” for next slideClick” for next slide
www.microcontrolsolutions.com
Micro Control SolutionsStability System II rev. 6.4
• Our stability software is a Part 11 compliant package
• Capable of monitoring a full scale stability operation
• Validation services available • On site training
• Visit us at: www.microcontrolsolutions.com
• Contact us at: [email protected]
Thank you for viewing our Thank you for viewing our presentationpresentation
““Click” to closeClick” to close