Metso Cooking 3400 Metso Cooking Liquor Measurement 3400 Digester control Continuous monitoring of alkali charging and all cooking phases Updated EA/AA concentration every second Reducing the Kappa variations by up to 50% Reducing the overall chemical consumption Low maintenance Automatic scaling compensation Continuous Lo-Solids Batch RDH

Transcript of Metso Cooking Liquor Measurement - Autekautek.no/datasheets/KEMOTRON-METSO/3400_001.pdf · 3400...

  • Me

    tso C

    oo

    kin

    g

    34

    00

    Metso Cooking Liquor Measurement3400

    Digester control

    Continuous monitoring of alkali

    charging and all cooking phases

    Updated EA/AA concentration

    every second

    Reducing the Kappa variations

    by up to 50%

    Reducing the overall chemical

    consumption

    Low maintenance

    Automatic scaling compensation

    Continuous Lo-Solids

    Batch RDH

  • Inline Cooking Measurement

    Continuous measurement is essential for

    performing e cient digester control.

    The sensor of the Cooking Measurement

    is constructed for direct installation into

    the liquor circulation. Based on the signals

    from the sensor, the Measurement provides

    continuous EA/AA measurement.

    Deposits on an in-line sensor can be sub-

    stantial, but the sensor design of the Metso

    Alkali Measurement limits the building-up

    of deposits as well as the e ects hereof.

    The sensor will measure conductivity from

    all available ions.

    When substantial changes in the composi-

    tion occur, it may be necessary to perform a

    1- or 2-point calibration.

    However changes in the S% by 5 will result

    in the EA being o by just 1%, without

    corrections.

    Terms of alkalinity, etc.

    • Active Alkali, AA = NaOH + Na2S

    as NaOH or Na2O (g/l)

    • E ective Alkali, EA = NaOH + 1/2 Na2S

    as NaOH or Na2O (g/l)

    • Sulphidity, S% = x 100(%)

    • Degree of causticizing,

    C% = x 100(%)

    Na2S

    NaOH + Na2S

    NaOH

    NaOH + Na2CO

    3

    The sensorsThe rugged 4-electrode sensor is made of stainless

    steel with the electrodes mounted on the outside

    of an isolator (PTFE). Within a measuring diameter

    of 200 mm (8”) diameter around the sensor elec-

    trode, a current is measured between one pair of

    electrodes and the potential di erence between

    another pair of electrodes.

    This picture illustrates how heavy the scaling can

    become while still having a functional sensor due to

    automatic balancing of the measuring eld. In addi-

    tion the Measurement provides scaling indication.

    The resultsSpeci! ed accuracy: 1–2 g/l EA Na

    2O compared to

    laboratory ABC tests (avg. of min. 3 samples from

    each test point).

    Results from a Scandinavian mill with a Metso

    Cooking measurement installed in the white liquor

    loading show deviations of only 0.5 g/l. Moreover

    the Metso sensors require less than 8 hours service

    per year.

    Circulation Measuring Standard range deviation

    g/l NaOH (STD)

    Transfer 14–29 g/l 1.4 g/l

    Trim 14–37 g/l 0.9 g/l

    Upper

    extraction liquor 9–13 g/l 0.5 g/l

    Lower

    extraction liquor 6–13 g/l 0.4 g/l

    Extraction 4–13 g/l 1.0 g/l

    Results from installation in various cooking

    circulations.

  • Batch process

    A mill installed a Metso Measurement in the cook-

    ing circulation of each batch digester.

    Metso Cooking Measurement installed in the circula-

    tion pump of a SuperBatch digester.

    In this way the mill was able to monitor the alkali

    level and thus the consumption of alkali. When a

    deviation from the standard cooking cycle oc-

    curred, the mill was able to adjust the after-feed of

    white liquor to the digester and thus compensate

    for the variations before the cook was ! nished. This

    improved the mill’s ability to reduce variations in

    the Kappa number.

    Continuous process

    A mill installed a Metso Cooking Measurement in

    the C6 trim circulation to be able to detect varia-

    tions in the alkali concentration caused by plugging

    in the boiler or by variations in the alkali of the

    white liquor or in the pulp quality.

    Metso Cooking Measurement installed in the C6 trim

    circulation in a continuous digester.

    With the continuous measurements and the

    counteraction against variations in the alkali

    concentration, the mill reported a decrease in the

    Kappa-variations from ±6 to ±3.

    Lo-Solids process

    The Lo-Solids digester contains a number of

    recirculation loops in order to remove the dissolved

    wood solids from the system as well as to control

    the alkali concentration by addition of white liquor.

    To compensate for variations in the cooking liquor a

    mill installed a number of Metso Cooking Measure-

    ment to be able to adjust the white liquor feed on

    an on-line basis.

    Kraft pulp mill applications

    Continuous Clari! ed white liquor

    process Transfer circulation

    Trim circulation

    MCC circulation

    ITC circulation

    Lower counter current loop

    Recirculation

    Extraction

    Lo-Solids Clari! ed white liquor

    Recirculation

    Upper extraction liquor

    Lower extraction liquor

    Modi! ed cooking circulation

    Wash circulation

    Extraction

    Batch process Clari! ed white liquor

    Hot black liquor

    Warm black liquor 2

    Hot white liquor

    Cooking liquor

    RDH process Clari! ed white liquor

    Warm ! ll liquor

    Hot ! ll liquor 1, 2, and 3

    Circulation liquor

    Cooking liquor

    M&D sawdust Clari! ed white liquor

    Pulp to the second

    postdigester

  • For more information, contact your local automation expert at Metso.

    www.metso.com/conductivity

    The information provided in this brochure contains descriptions or characteristics of performance

    which in case of actual use do not always apply as described or which may change as a result of

    further development of the products.

    An obligation to provide the respective characteristics shall only exist if expressly agreed in the

    terms of contract. Availability and technical speci cations are subject to change without notice.© M

    ets

    o A

    uto

    ma

    tio

    n In

    c. 1

    2/2

    01

    0 B

    18

    3 0

    00

    .0-E

    N

    Installation of the Metso Cooking Measurement

    Metso Cooking Measurement sensor installed in a measuring pipe. It is placed in a bypass loop, thus providing

    safe withdrawal of the sensor during the digester operation in case of the need for removal of any substantial

    deposits.

    A rack of Cooking Measurement monitors and sensors. Sensor mounted in-line.

    Cooking liquor

    Cooler

    Sample

    Measurement

    Measuringpipe

    Mounting across a pump

  • For more information, contact your local automation expert at Metso.

    www.metso.com/conductivity

    The information provided in this brochure contains descriptions or characteristics of performance

    which in case of actual use do not always apply as described or which may change as a result of

    further development of the products.

    An obligation to provide the respective characteristics shall only exist if expressly agreed in the

    terms of contract. Availability and technical speci cations are subject to change without notice.© M

    ets

    o A

    uto

    ma

    tio

    n In

    c. 1

    2/2

    01

    0 B

    18

    3 0

    00

    .0-E

    N

    Metso CookingLiquor Measurements3400Speci! cations Concentration ranges: 27 preprogrammed recipes for circulating loops of batch and continuous digesters

    Output: Two current outputs 4 - 20 mA for concentration, conductivity or temperature

    Temperature measurement: –40 to +250°C

    Display: LCD Sensor connection: Series 4000 sensors with 11-pole strip connector and MF20 cable adaptor

    Local or remote measuring range selection: Four cooking set-up modes.

    Control voltage: 12 – 30 V DC

    HART® communication is available EnclosureMaterial: Cast aluminium, PE coated

    Protection: IP67

    Dimensions: 144 x 144 x 107 mm

    Mounting: Panel, wall or pipe Ambient temp.: -10 to + 60°C

    Storage temp.: -20 to + 70 °C

    Weight: 2.3 kg

    Wall Panel

    Pipe

    Mounting options

    Pipe mounting kits

    Type For pipeNo. dimension

    4902 a 25-38 mm b 35-52 mm c 50-73 mm d 72-94 mm e 82-114 mm

    Dimensions

    Wall mounting Type 3407 Type 3417

    Panel mounting Type 3408 Type 3418

    Power supply Loop powered Line powered

    16 – 30 V DC 85 – 265 V AC,

    on mA1 6 VA

    Alarm No alarm Two relays

    250 V AC, 8 A

    Display Non-Illuminated illuminated

  • For more information, contact your local automation expert at Metso.

    www.metso.com/conductivity

    The information provided in this brochure contains descriptions or characteristics of performance

    which in case of actual use do not always apply as described or which may change as a result of

    further development of the products.

    An obligation to provide the respective characteristics shall only exist if expressly agreed in the

    terms of contract. Availability and technical speci cations are subject to change without notice.© M

    ets

    o A

    uto

    ma

    tio

    n In

    c. 1

    2/2

    01

    0 B

    18

    3 0

    00

    .0-E

    N

    World wide support for Metso Concentration Measurements

    Go to www.metso.com/conductivity to nd your local expert