Method Expert: Guided, Automated Method Development for the HORIBA LA-950

19
© 2010 HORIBA, Ltd. All rights reserved. The Revolutionary Method Expert Guided, Automated Method Development for the LA- 950 Ian Treviranus [email protected] www.horiba.com/us/particle

description

Ian Treviranus, Product Line Manager for HORIBA Particle, presents the Method Expert software for the LA-950. The Method Expert provides guidance and a high degree of automation to the classic challenge of method development. This presentation is archived with the original webinar video in the Download Center at www.horiba.com/us/particle.

Transcript of Method Expert: Guided, Automated Method Development for the HORIBA LA-950

Page 1: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

The Revolutionary Method ExpertGuided, Automated Method Development for the LA-950

Ian [email protected]/us/particle

Page 2: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

One Important Question

Q: How can we help users solve particle size problems “offline”?

Page 3: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

One Important Question

A: Provide expert guidance which is a mouse-click away

Page 4: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

A Revolutionary Idea

The goal is to create an invisible foundation of support

Page 5: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

A Revolutionary Idea

The LA-950 is the perfect match for the Method Expert concept

Page 6: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

A Revolutionary Idea

Method development is the most complex, most important, and most misunderstood facet of using a particle size analyzer

Page 7: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

A Revolutionary Idea

Simplify this process by automating tests and providing clear explanations at every step

Page 8: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

A Revolutionary Idea

A great method is…

robust

accurate

reproducible

Page 9: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

A Revolutionary Idea

A great method is…

robust

accurate

reproducible

Great methods optimize the hardware and the software conditions to achieve the best data

Page 10: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Collecting and Calculating

The LA-950 hardware collects scattered light data

The LA-950 software calculates the particle size distribution using that scattered light data

Both must be optimized to

maximize data quality

Page 11: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Measurement Optimization

There are four important tests…

Circulation

Concentration

Dispersion

Duration

Page 12: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Calculation Optimization

There are two important tests…

Real RI

Imaginary RI

Page 13: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Basic Test Design

Why is the test important?

What does the test do?

How will the results be displayed?

What is the best value?

User selects up to 5 values for testing

Page 14: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Basic Test Design

Method Expert guides user to prepare the LA-950 for each test

Results displayed in multiple formats:

PSD, D50, R-parameter

Page 15: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Automation Wizard

Wouldn’t it be great if you could take all these test results and build some kind of program that does everything with only one mouse-click?

Page 16: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Automation Wizard

Yeah, it is pretty great.

Page 17: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Automation Wizard

Page 18: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

Automation Wizard

Page 19: Method Expert: Guided, Automated Method Development for the HORIBA LA-950

© 2010 HORIBA, Ltd. All rights reserved.

For More Details

Visit www.horiba.com/us/particle

Contact us directly at [email protected]

Download the Method Expert white paper