Metered PDU - IEC Socket

2
Power Solutions Metered Power Distribution Units Indian & Multi Pin Socket Metered PDU - IEC Socket 1Ph, 230V, 32A, 1U Metered standard rack mount Metered power distribution unit with 12 X C13, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black 1Ph, 230V, 32A, 1U Metered standard rack mount Metered power distribution unit with 8 X C19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black MPDU-H-1-IEC-F12-X4-Y2-Z0 1 2 MPDU-H-1-IEC-G8-X4-Y2-Z0 1Ph, 230V, 32A, 1U standard rack mount Metered power distribution unit with 4 X C13 & 4 XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black 3 MPDU-H-1-IEC-F4-G4-X4-Y2-Z0 1Ph, 230V, 32A, 2U standard rack mount power Metered distribution unit with 20X C13 & 4 XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black MPDU-H-1-IEC-F20-G4-X4-Y2-Z0 4 1Ph, 230V, 32A, 1U Metered standard rack mount Metered power distribution unit with 12 X C13, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black MPDU-H-1-IEC-F12-X4-Y2-Z0-UL 5 Note : Other Socket configuration available on request Rack Power & Electronics IEC Socket Version - 2016 - 001

Transcript of Metered PDU - IEC Socket

Page 1: Metered PDU - IEC Socket

Power Solutions Metered Power Distribution Units Indian & Multi Pin SocketMetered PDU - IEC Socket

1Ph, 230V, 32A, 1U Metered standard rack mount Metered power distribution unit with 12 X C13, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

1Ph, 230V, 32A, 1U Metered standard rack mount Metered power distribution unit with 8 X C19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

MPDU-H-1-IEC-F12-X4-Y2-Z01

2 MPDU-H-1-IEC-G8-X4-Y2-Z0

1Ph, 230V, 32A, 1U standard rack mount Metered power distribution unit with 4 X C13 & 4 XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

3 MPDU-H-1-IEC-F4-G4-X4-Y2-Z0

1Ph, 230V, 32A, 2U standard rack mount power Metered distribution unit with 20X C13 & 4 XC19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

MPDU-H-1-IEC-F20-G4-X4-Y2-Z04

1Ph, 230V, 32A, 1U Metered standard rack mount Metered power distribution unit with 12 X C13, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

MPDU-H-1-IEC-F12-X4-Y2-Z0-UL5

Note : Other Socket configuration available on request

Rac

k Po

wer

& E

lect

roni

cs

IEC Socket

Version - 2016 - 001

Page 2: Metered PDU - IEC Socket

Metered PDU - IEC Socket

Rac

k Po

wer

& E

lect

roni

cs

Note : Other Socket configuration available on request

1Ph, 230V, 32A, Zero U standard rack mount Metered power distribution unit with 12 X C13, Inlet Plug (Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

1 MPDU-V-1-IEC-F12-X4-Y4-Z0

1Ph, 230V, 32A, Zero U standard rack mount Metered power distribution unit with 12X C13 & 4 X C19, Inlet Plug (Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

2 MPDU-V-1-IEC-F12-G4-X4-Y4-Z0

1Ph, 230V, 32A, Zero U standard rack mount Metered power distribution unit with 20 X C13 & 4 X C19, Inlet Plug (Inlet Plug Not Installed, Recommended IEC30932A 2P+E), 16A MCB X 2 Circuits - PDU Rating 7.3KVA/Bottom feed-3Mt/ Black

3 MPDU-V-1-IEC-F20-G4-X4-Y4-Z0

IEC Socket

Version - 2016 - 001