Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network....

15
American Electric Power 4.5 Advanced Metering Infrastructure Document ID: Use case # 5.11 Title: Meter Remote Connect / Disconnect Use Case Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons Copyright © 2011 American Electric Power Company Meter Remote Connect / Disconnect Version History Rev. Date Author Change description A 03/07/2011 David McClendon Initial Release B 03/14/2001 David McClendon Include AMI-Head initial reply C 08/08/2011 AEP Workshop Various updates D 08/18/2011 Tim Simmons Implement various requested updates E 10/03/2011 Brian D. Green Add Narrative, Interface Diagram, Notes section and update the Actors and steps F 10/31/2011 Ron Cunningham Final team review "Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-OE0000193." Disclaimer: "This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof."

Transcript of Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network....

Page 1: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Copyright © 2011 American Electric Power Company

Meter Remote Connect / Disconnect

Version History Rev. Date Author Change description

A 03/07/2011 David McClendon Initial Release B 03/14/2001 David McClendon Include AMI-Head initial reply C 08/08/2011 AEP Workshop Various updates D 08/18/2011 Tim Simmons Implement various requested updates

E 10/03/2011 Brian D. Green Add Narrative, Interface Diagram, Notes section and update the Actors and steps

F 10/31/2011 Ron Cunningham Final team review

"Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-OE0000193."

Disclaimer: "This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information,

apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or

service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily

state or reflect those of the United States Government or any agency thereof."

Page 2: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 2 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Summary:

This use case addresses the messages exchanged between CIS and Smart Meter through the AMI Head-End and AMI Network when a meter connect/disconnect request is issued by CIS.

Narrative: Traditionally, utilities send a metering service person to connect or disconnect the meter. With an AMI system, the connect/disconnect can be performed remotely by switching the internall meter switch in the Smart Meter for any of the following possible reasons:

Remote Connect for Move-In Remote Connect for Reinstatement on Payment Remote Disconnect for Move-Out Remote Disconnect for Non-Payment Remote Disconnect for Emergency Load Control Unsolicited Connect / Disconnect Event

A remote disconnect is issued in the Customer Information System (CIS) by the Customer Service Representative (CSR) for a legitimate reason. The message is sent to the AMI Head-End and routed to the appropriate Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted and sent on to the Meter Metrology Board (part of the Smart Meter) where the board causes the Internal Meter Switch (part of the Smart Meter) to connect or disconnect (depending on the command) and sends a confirmation back to the Meter Metrology Board to the NIC to the AMI Head-End via the AMI Network. The AMI Head-End sends the confirmation to CIS and to the Operational Data Store (ODS) where it is logged as a meter event.

Page 3: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 3 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Interface Diagram:

AMI Head-End

Smart Meter

Operations

Customer

AMI Network

3

CIS ODS

30 29

2

Note(s):

The NIC, Meter Metrology Board and the Internal Meter Switch are all parts of the Smart Meter.

Page 4: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 4 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Actor(s):

The list of the actors and the roles that are participating in this use case described in the table below.

Name Role description

AMI Head-End The AMI Head-End is the back office system that controls the Advanced Metering Infrastructure

AMI Network The AMI network provides the communications between the AMI Head-End and the meters

CIS Customer Information System is the system in place for customer data and billing

Customer Service Representative

(CSR), Initiates the Connect/Disconnect request via the CIS.

Internal Meter Switch The switch within the Smart Meter that can be remotely operated to connect or disconnect power to the premise.

Meter Metrology Board Internal board in Smart Meter trips or closes Service Switch

NIC AMI network interface component with Meter Metrology Board within the Smart Meter

ODS Operational Data Store subscribes to Connect and Disconnect messages.

Participating Business Functions:

The participating business function, its acronym and what they provide in this use case are detailed in the table below.

Acronym Business Function/Abstract Component Services or Information Provided

CIS Customer Information System Supplies initial Connect/Disconnect request.

AMI Advanced Metering Infrastructure for energy monitoring and recording, load control capability, tariff/rate data collection.

Energy monitoring and control, configuration of advanced meters, offers new rate programs, distribution automation, Meter Readings, Meter Events and Alarms.

ODS Operational Data Store Store Connect/Disconnect events.

Page 5: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 5 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Assumptions / Design Considerations:

• Standard International Electrotechnical Commission (IEC) 61968 Message Definition format will be followed to provide the Header, Request, Reply, and payload used when defining the messages for the design specifications. For the purpose of the use cases identified in this document these have been omitted as they are to be provided in the design specification for the Meter Remote Connect/Disconnect use case.

Normal Sequence:

The sequences of events, showing the order in which they ocurr during the typical progression of this use case are provided in the table below. The Sequence Diagram that graphically depicts the events is presented immediately following the table.

S1: A Customer Service Representative initiates a Remote Meter Connect request via CIS.

Use Case Step

Triggering Event

Description Of Process Information To Be Exchanged

Producer Receiver Message Type

1 Remote Connect initiated by CSR

A CSR creates a Remote Meter Connect request and sends it to CIS

Internal

2 CIS creates a Remote Meter Connect Message

Remote Meter Connect Message

CIS Internal Create /EndDeviceControls

3 CIS sends the Remote Meter Connect Message to the AMI Head-End

Remote Meter Connect Message

CIS AMI Head-End

Create /EndDeviceControls

4 AMI Head-End issues a Reply to the Remote Meter Connect Message to CIS

Acknowledgement

AMI Head-End

CIS Reply /EndDeviceControls

5 AMI Head-End sends Remote Meter Connect Message to the NIC via the AMI Network

Remote Meter Connect Message

AMI Head-End

AMI Network

Proprietary

Page 6: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 6 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Use Case Step

Triggering Event

Description Of Process Information To Be Exchanged

Producer Receiver Message Type

6 AMI Network routes Remote Meter Connect Message to the NIC

Remote Meter Connect Message

AMI Network

NIC Proprietary

7 NIC sends Remote Meter Connect Message to Meter Metrology Board

Remote Meter Connect (ANSI C12.19 Table Data) Message

NIC Meter Metrology Board

Write ANSI C12.19 Table Data

8 Remote Connect (close meter switch) request processed

Meter Metrology Board sends Closed Internal Meter Switch Verification to NIC

Closed Internal Meter Switch Verification (ANSI C12.19 Table Data) Message

Meter Metrology Board

NIC Send ANSI C12.19 Table Data

9 NIC sends Closed Internal Meter Switch Verification to AMI Head-End via the AMI Network

Closed Internal Meter Switch Verification

NIC AMI Network

Proprietary

10 AMI Network routes Closed Internal Meter Switch Verification to AMI Head-End

Closed Internal Meter Switch Verification

AMI Network

AMI Head-End

Proprietary

11 AMI Head-End passes Closed Internal Meter Switch Verification to CIS

Closed Internal Meter Switch Verification

AMI Head-End

CIS Created /EndDeviceEvents

12 AMI Head-End passes Closed Internal Meter Switch Verification to ODS

Closed Internal Meter Switch Verification

AMI Head-End

ODS Created /EndDeviceEvents

Page 7: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 7 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Page 8: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 8 of 15 Copyright © 2011 American Electric Power Company Rev. 7

S2: A Customer Service Representative initiates a Remote Meter Disconnect request via CIS.

Use Case Step

Triggering Event

Description Of Process Information To Be Exchanged

Producer Receiver Message Type

1 A remote disconnect is initiated by a CSR

A CSR creates a Remote Meter Disconnect Request to CIS

Internal

2 CIS creates a Remote Meter Disconnect Message

Remote Meter Disconnect Message

CIS Internal Create /EndDeviceControls

3 CIS sends Remote Meter Disconnect Message to AMI Head-End

Remote Meter Disconnect Message

CIS AMI Head-End

Create /EndDeviceControls

4 AMI Head-End issues a reply to the Remote Meter Disconnect Message to CIS

Acknowledgement

AMI Head-End

CIS Reply /EndDeviceControls

5 AMI Head-End passes Remote Meter Disconnect Message to NIC Via AMI Network

Remote Meter Disconnect Message

AMI Head-End

AMI Network

Proprietary

6 AMI Network routes Remote Meter Disconnect Message to NIC

Remote Meter Disconnect Message

AMI Network

NIC Proprietary

7 NIC sends Remote Meter Disconnect Message to Meter Metrology Board

Remote Meter Disconnect (ANSI C12.19 Table Data) Message

NIC Meter Metrology Board

write ANSI C12.19 Table Data

8 Remote Disconnect (open meter switch) request processed

Meter Metrology Board sends Internal Meter Switch Opened Verification to NIC

Open Internal Meter Switch Verification(ANSI C12.19 Table Data) Message

Meter Metrology Board

NIC ANSI C12.19 Table Data

Page 9: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 9 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Use Case Step

Triggering Event

Description Of Process Information To Be Exchanged

Producer Receiver Message Type

9 NIC sends Open Internal Meter Switch Verification to AMI Head-Enid via the AMI Network

Open Internal Meter Switch Verification

NIC AMI Network

Proprietary

10 AMI Network routes Open Internal Meter Switch Verification to AMI Head-Enid

Open Internal Meter Switch Verification

AMI Network

AMI Head-End

Proprietary

11 AMI Head-End passes Open Internal Meter Switch Verification to CIS

Open Internal Meter Switch Verification

AMI Head-End

CIS Created /EndDeviceEvents

12 AMI Head-End passes Open Internal Meter Switch Verification to ODS

Open Internal Meter Switch Verification

AMI Head-End

ODS Created /EndDeviceEvents

Page 10: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 10 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Page 11: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 11 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Integration Scenarios

Adapters will use the Common Information Model (CIM) in Extensible Markup Language (XML) to send and receive messages and events.

The following are the points of integration that must be tested for this use case. Other non-CIM message interfaces may be testable in this use case.

Actor Interface Points

CIS • AMI Head-End

AMI Head-End • AMI Network • ODS

Pre-conditions:

The following conditions that MUST be met before this use case can occur.

• CIS must have a list of valid Meter IDs

• Meter to be connected/disconnected must be installed and registered with the AMI head-end system

Post-conditions:

The following events or actions that may happen after or be caused by the completion of the normal use case events, as well as the exceptions or alternative sequences are:

• If the Meter does not respond after the Remote Connect/Disconnect comand, further actions will be required from the CSR.

Page 12: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 12 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Exceptions / Alternate Sequences:

There are no exceptions, unusual events or alternate sequences defined for this use case.

Use Case Step

Triggering Event

Description Of Process Information To Be Exchanged

Producer Receiver Message Type

Page 13: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 13 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Message Type(s) Diagram:

The following XML Schema Definition (XSD) diagram shows the normative and informative parts of the message. Not all of the International Electrotechnical Commission’s (IEC) – CIM message optional elements must or will be used in the use of IEC – CIM for this specific use case.

Page 14: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 14 of 15 Copyright © 2011 American Electric Power Company Rev. 7

Page 15: Meter Remote Connect / Disconnect Remote Connect Disconnect... · Smart Meter via the AMI Network. When the message is received at the NIC (part of the Smart Meter), it is converted

American Electric Power 4.5 Advanced Metering Infrastructure

Document ID: Use case #

5.11

Title: Meter Remote Connect / Disconnect Use Case

Subject Matter Expert: Author: Reviewed by: Margaret Goodrich David McClendon Tim Simmons

Page 15 of 15 Copyright © 2011 American Electric Power Company Rev. 7

References:

Use Cases or other documentation referenced by this use case include:.

• 20100625 AEP Ohio Interoperability Plan V1.docx: Section 4.5.11 (Remote Connect/Disconnect from CIS)

• 20100625 Use Cases EPRI Report_V2.4.docx: Section 5.10 (Remote Connect/Disconnect)

• 61968_9_MeterReadingAndControl_FDIS090428-final.docx: Section 5.5.2.4 (Meter disconnect and reconnect); Annex H (XML Schemas for message payloads) Section H.4 (EndDeviceControls)

Issues: None

ID Description Status

Miscellaneous Notes: None