Metal Seal/Rubber Seal Base Mounted SeriesVQ · SeriesVQ Base Mounted The photo does not show an...
Transcript of Metal Seal/Rubber Seal Base Mounted SeriesVQ · SeriesVQ Base Mounted The photo does not show an...
Series VQBase Mounted
The photo does not show an actual use example.
DIN rail
A variety of options
VQ1000(VV5Q11)
VQ2000(VV5Q21)
VQ0000(VV5Q05)
Push-locking lever style
Push-lockingslotted style
Regulator unit
Elbow fitting ass'y(top entry connector)
Elbow fitting ass'y(bottom entry connector) Individual EXH spacer
Individual SUP spacer
Port plug2 stations matching fittings
Ejector unitBuilt-in silencer·Direct exhaust
Blank plateass'y
All pilot valves are compactly mounted onone side. The space saving design of mounting all fittings on one side permitsmounting in three directions.
The non-bis, one-clamp structure permitseasy valve replacement. (Plug-in Unit)
Small space and small volume
Innovative mounting methods
Built-in One-touch fittingsfor easy piping
Mounting space………
Mounting volume……45% DOWN
50% DOWN
VQ0000
VQ1000
VQ2000
10ms
10ms
20ms
200 million cycles
Dispersion accuracy ±2ms
A variety of commom wiringmethods are standardized.
ModelManifold
pitch(mm)
Cv
Metalseal
Rubberseal
Cylinderspeed
VQ0000
VQ1000
VQ2000
11
10.5
16
0.15
0.20
0.80
0.2
0.30
0.90
up to ø40
up to ø50
up to ø80
Unprecedented high speedresponse and long service life (Metal seal, single, with indicator light and surge voltage suppressor)
Thin compact design withlarge flow capacity
Kit(D-sub connector)Number of pins: 15, 25
Kit(Flat cable withterminal block)Number of pins: 20
Kit(Terminal box)
Kit(Lead wire)
Kit(Serial transmission unit)
Kit(Flat cable connector)Number of pins: 10, 16, 20, 26
Top entry Top entrySide entry Side entry
F P
G T L S
Metal Seal/Rubber Seal
1.10-111
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
1.10-112
Bas
e M
ou
nte
dP
lug
lead
Plu
g-i
n
Sin
gle
Do
ub
le
3 p
osi
tio
n
Sin
gle
Do
ub
le
Clo
sed
cen
ter
Exh
aust
cen
ter
Pre
ssu
re c
ente
r
Plu
g-i
n
Gro
mm
et
M p
lug
co
nn
ecto
r
L p
lug
co
nn
ecto
r
No
n-l
ock
ing
pu
sh s
tyle
Pus
h-lo
ckin
g sl
otte
d st
yle
Pus
h-lo
ckin
g le
ver
styl
e
P.1.10-122
P.1.10-168
Effectiveareamm2
(Cv factor)
Configuration Voltage Electrical entry Manual override
VQ100
Met
al s
eal
Ru
bb
er s
eal
Met
al s
eal
Ru
bb
er s
eal
Met
al s
eal
Ru
bb
er s
eal
Met
al s
eal
Ru
bb
er s
eal
VQ101
VQ200
VQ201
VQ050
VQ051
VQ110
VQ111
12V24VDC
100V110VAC
200V220VAC50/60
Hz50/60
Hz
VQ1000Series
VQ2000Series
VQ0000Series
VQ1000Series
P.1.10-120
P.1.10-118
P.1.10-164
P.1.10-166
3.6(0.2)
3.6(0.2)
5.4(0.3)
5.4(0.3)
14.4(0.8)
12.6(0.7)
16.2(0.9)
14.4(0.8)
2.7(0.15)
2.0(0.11)
3.6(0.2)
2.7(0.15)
5.4(0.3)
5.4(0.3)
3.6(0.2)
3.6(0.2)
Valve Specifications
P.1.10-168
P.1.10-122
1.10-113P
.1.10-197
Man
ifold
Op
tion
sO
ptio
ns
P.1.10-159
P.1.10-148
P.1.10-159
P.1.10-197
P.1.10-192
P.1.10-154
P.1.10-190
Except for L kit
Standard
Contact SMC for S kit
Except for L kit
Contact SMC for S kit
Except for L kit
Contact SMC for S/G kit
Except for L kit
Contact SMC for S/G kit
External pilot
D-sub connector 15 pin
Flat cable 10 pin, 16 pin, 20 pin
Negative COM specifications
One-touch fitting/Inch size
For special wiring spec.
Blank plate
Individual SUP/EXH
SUP/EXH passage spacer
Name plate
DIN rail mounting
Built-in silencer
Silencer for EXH port
Elbow fitting for cylinder port
Plug for cylinder port
Ragulator unit
Ejector unit mounted
Double check block
Check valve for prevention ofback pressure
Two stations matching fittings fordouble flow rate
SY
SY
J
SX
VK
VZ
VF
VF
R
VP
7
VP
4
VQ
4
VQ
Z
VQ
D
VZ
S
VF
S
VS
VS
7
VQ
1.10-114
SeriesVQ/Base Mounted: VariationsSeriesVQ/Base Mounted: Variations
Manifold Variations
F
P.1.10-124 P.1.10-128 P.1.10-132
P.1.10-124 P.1.10-128 P.1.10-132
P.1.10-170 P.1.10-174
P.1.10-170 P.1.10-174 P.742
D-sub connectorConforming to MILD-sub connector
Flat cable connectorConforming to MILflat cable connector
Flat cable with powersupply terminal block
Conforming to MIL flat cableconnector.Applicable to OMRON'sserial transmission unit.
Kit
PKit
GKit
VQ1000Series
VQ2000Series
VQ0000Series
VQ1000Series
Plu
g-i
nP
lug
lead
1.10-115
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Manifold Variations
L
L
C
C
P.1.10-136 P.1.10-140 P.1.10-144
P.1.10-136 P.1.10-140 P.1.10-144
P.1.10-178 P.1.10-182 P.1.10-186
P.1.10-178 P.1.10-182 P.1.10-186
Lead wireDirect electrical entry style
Serial transmission unitEnables single-wire solenoid valve-PLC operation
kit
kit
kit
kit
Port size
SUPEXH port
Cylinder port
P, R A, B
C3 (ø3.2)C4 (ø4)C6 (ø6)M5 (M5 thread)
N1 (ø1/8”)N3 (ø5/32”)N7 (ø1/4”)
C3 (ø3.2)C4 (ø4)M5 (M5 thread)
N1 (ø1/8”)N3 (ø5/32”)
C8 (ø8)
N9 (ø5/16”)
C4 (ø4)C6 (ø6)C8 (ø8)
N3 (ø5/32”)N7 (ø1/4”)N9 (ø5/16”)
C10 (ø10)
N11 (ø3/8”)
C3 (ø3.2)C4 (ø4)C6 (ø6)M5 (M5 thread)
N1 (ø1/8”)N3 (ø5/32”)N7 (ø1/4”)
C8 (ø8)
N9 (ø5/16”)
<Option>Built-in silencer
<Option>Built-in silencer
<Option>Built-in silencer
<Option>Built-in silencer
C6 (ø6)
N7 (ø1/4”)
Terminal box (Terminal block)
Terminal blocks are compactly arranged on one side.
Tkit kit kit
L C S
Terminal box
Enclosure IP65available
Enclosure IP65available
Enclosure IP65available
Terminal block
Terminal block
1.10-116
Series VQ0000
Model
VQ0000
(Metal seal)
ø42.7
(0.15)
ø43.6
(0.2)
ø10ø6 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100150300450600750150300450600750
VQ0001
(Rubber seal)
Fitting(One-touch fitting)
Effective area(mm2) (Cv factor)
Cylinderspeed(mm/s)
Cylinder bore size (mm)
Series CJ2Pressure 0.5MPaLoad factor 25%Piping length 2mSpeed controller: AS2000F-06 (S=4.5mm2)Cylinder stroke 50mm
Series CM2Pressure 0.5MPaLoad factor 50%Piping length 5mSpeed controller: AS2000F-06 (S=4.5mm2)Cylinder stroke 100mm
Series CA1Pressure 0.5MPaLoad factor 50%Piping length 5mSpeed controller: AS2000F-06 (S=4.5mm2)Cylinder stroke 300mm
Series VQ1000
150300450600750150300450600750
Series CJ2Pressure 0.5MPaLoad factor 25%Piping length 2mSpeed controller: AS3000F-06 (S=6.5mm2)Cylinder stroke 50mm
Series CM2Pressure 0.5MPaLoad factor 50%Piping length 5mSpeed controller: AS3000F-06 (S=6.5mm2)Cylinder stroke 100mm
Series CA1Pressure 0.5MPaLoad factor 50%Piping length 5mSpeed controller: AS3000F-06 (S=6.5mm2)Cylinder stroke 300mm
Series VQ2000
150300450600750150300450600750
Cylinder Speed Chart
Model
VQ1000
(Metal seal)
ø63.6
(0.2)
ø65.4
(0.3)
VQ1001
(Rubber seal)
Fitting(One-touch fitting)
Effective area(mm2) (Cv factor)
Cylinderspeed(mm/s)
Model
VQ2000
(Metal seal)
ø814.4
(0.80)
ø816.2
(0.90)
VQ2001
(Rubber seal)
Fittings(One-touch fitting)
Effective area(mm2) (Cv factor)
Cylinderspeed(mm/s)
Cylinder bore size (mm)
ø10ø6 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
Cylinder bore size (mm)
ø10ø6 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
Series CJ2Pressure 0.5MPaLoad factor 25%Piping length 2mSpeed controller: AS3000F-08 (S=10mm2)Cylinder stroke 50mm
Series CM2Pressure 0.5MPaLoad factor 50%Piping length 5mSpeed controller: AS3000F-08 (S=10mm2)Cylinder stroke 100mm
Series CA1Pressure 0.5MPaLoad factor 50%Piping length 5mSpeed controller: AS3000F-08 (S=10mm2)Cylinder stroke 300mm
1.10-118
VQ1000Base Mounted
Plug-in UnitHow to Order Manifold
Option
Kit
Option
None Check valve for prevention of back pressure
DIN rail mounting1 set of regulator unit
2 sets of regulator unit 3 sets of regulator unit
With vacuum ejector unit Special wiring specification (Not double wiring)
With name plateExternal pilot
Built-in silencer (Direct exhaust)
(2)
(3)
(3)
(3)
(4)
(5)
(6)
BD
G1G2G3 JKNRS
U0U1U2U3
FFS0S1S2S3
ManifoldPlug-in unit
VV5Q 1 U1F1 08 C6
1 station
… …
01
1
VQ10001
Stations
With cable (1.5m)With cable (3m)With cable (5m)
P.1.10-124 P.1.10-128
P.1.10-140
P.1.10-136
P.1.10-132
P.1.10-144
Without cable
Connector locationTop (vertical) Side (honzontal)
One-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6
M5 threadMixed size/with port plug (1)
Elbow One-touch fitting ø3.2 for top pipingElbow One-touch fitting ø4 for top piping
Symbol Port size Symbol
Symbol
Port sizeC3C4C6M5CML3L4
L6L5B3B4B6B5LM
Cylinder ports
Series
The min. and max.number of stationsdiffers from kit to kit.(Refer to the tablebelow)
Kit/Electrical entry/Cable length
Kit(D-sub connector)
Note 1) Besides the above, F and P kits with different number of pins are available. Refer to p1.10-159 for details.Note 2) Refer to p.1.10-160 for details.
Kit Kit
F
Kit(Terminal box)
T Kit O Terminal box 2 to 24 stations (2)
T
U0U1U2U3
S0S1S2S3
Kit(Lead wire cable)
LKit
012
With cable (0.6m)With cable (1.5m)With cable (3m)
1 to 8stations
L Kit(Serial transmission unit)S
U0U1U2U3
PPS0S1S2S3
Kit(Flat cable connector)P
0123
G2 to 16 stations
Kit(Flat cable connector with power supply terminal block)G
Elbow One-touch fitting ø6 for top pipingElbow M5 thread for top pipingElbow One-touch fitting ø3.2 for bottom pipingElbow One-touch fitting ø4 for bottom pipingElbow One-touch fitting ø6 for bottom pipingElbow M5 thread for bottom piping
Mixed size for elbow piping
Compatible only with24VDC valves.
SKit
OABCDEF1GHJ1J2KQR1R2V
Without SI unitWith general type, Series EX300
SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)
SI unit for MEWNET-F System (Matsushita Electric Works Ltd.) SI unit for 16 point Uni-wire System (NKE)
SI unit for Remote I/O (RIO) System (Allen-Bradley Co.)SI unit for 16 point Uni-wire H System (NKE)
SI unit for 16 point S-LINK System (Sunx)SI unit for 8 point S-LINK System (Sunx)
SI unit for T-LINK Mini System (Fuji Electric)SI unit for Device Net and Compo Bus/D (OMRON)
SI unit for 16 point Compo Bus/S (OMRON)SI unit for 8 point Compo Bus/S (OMRON)SI unit for CC-LINK (Mitsubishi Electric)
Max.16 stations
Max.16 stations
Max. 8
Max. 8Max. 16
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Options” on p.1.10-161 for One-touch fittings in inch sizes. Note 3) M5 fittings for M5 thread are attached without being incorporated.
Note 1) If specifying more than one option, please list alphabetically. Example) -BRS
Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. If not all stations need this check valve, specify the stations where check valves are installed by using a manifold specification form.
Note 3) Specify the mounting position by means of the manifold specification form.
Note 4) Refer to p.1.10-152 for the details of ejector mounted styles. A combination of “J” and “N” is unavailable.
Note 5) Specify the wiring by means of the manifoldspecification form. (Except for L kit)
Note 6) Indicate “R” for the valve with external pilot.
2 to 24stations
With cable (1.5m)With cable (3m)With cable (5m)
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
Without cable
Kit Kit Kit
2 to 24stations
Connector locationTop (vertical) Side (honzontal)
The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24V DC. The dust proof SI unit is also available. Refer to p.1.10-144 for details.
(2) (2) (2)
(2)
1.10-119
Note) Refer to “Options” on p.1.10-160 and 1.10-161 for external pilot and negative COM specifications.
How to Order Valve How to Order Manifold Ass'y (Example)
Manifold Options
Configuration2 position single
VQ 1 51 0 0 Y
1
2 position double
2
3 position closed center
3
3 position exhaust center
4
3 position pressure center
5
VQ10001
MetalRubber
Seal
Series
Note 1) Refer to p.1.10-122 for AC.
Refer to p.1.10-157 for cylinder port fittings.Refer to p.1.10-209 for replacement parts.
Note 1) Unapplicable to the S kit.
01
Specification
Standard
Highpressure
Lowwattage
Pilot valve
Manual override
Symbol
–
H(1)
Y(1)
DC AC
100V AC (50/60Hz)200V AC (50/60Hz)110V AC (50/60Hz)220V AC (50/60Hz)
24V DC12V DC
Coil voltage
Ordering example
12(1)
34(1)
56
YesNo
– E (1)
– B Push-lockingslotted style
Non-lockingpush style
Push-lockinglever style
C
Specify valve and option nos. below the manifold base No.When arrangement is complicated, specify the nos. byusing a manifold specification form.
1 set (F kit 9 station manifold base No.)4 sets (Single solenoid No.)4 sets (Double solenoid No.)1 sets (Blank plate No.)
P.1.10-148
VVQ1000-10A-1Blank plate assembly
VVQ1000-16ASUP block plate
VVQ1000-FPG-Double check block
VVQ1000-52A-C82 stations matching fitting assembly
KQP- -X19Blank plug
VVQ1000-P-1-C6Indivdual SUP spacer
VVQ1000-19A- -
23040608
EXH block plate assemblyVVQ1000-F-LElbow fittings assembly
AN200-KM8Silencer (EXH port)
VVQ1000-1C-Blank plate with connector
VVQ1000-R-1-C6Individual EXH spacer
VVQ1000-18A
Check valve for prevention of backpressure assembly [-B]
VVQ1000-57ADIN rail mounting bracket [-D]
VVQ1000-AR-1Regulator unit
[-J]Vacuum ejector unit
VVQ1000-N-Station (1 to Max. stations)Name plate [N] Built-in silencer, direct exhaust [-S]
VVQ0000-58APort plug
VV5Q11-09C6FU2∗VQ1100-5∗VQ1200-5∗VV1000-10A-1
…………………
…
(1.0W)
(1)
(1.5W)
(0.5W)
Indicator light andsurge voltagesuppressor
The ∗ mark is an assembing mark. Prefix with “∗” to mark parts for ass'y nos. ofsolenoid valves, etc.
Note 1) 200/220V AC models are applicable to F and L kits.
C3C4C6M5
FPL
C3C4C6M5
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 1000/2000 Plug-in UnitBase Mounted
1644
L
8
14 25
1 13
47.04
55 2-M2.6 X 0.45
Socket side
Terminal No.
≅ø10
Multicore vinyl cable0.3mm2 X 25C
1.10-124
Terminal No.123456789
10111213141516171819202122232425
–––––––
WhiteBlackBlackRedRedRed
BlackBlackWhite
––
BlackWhiteWhiteRedRed
White–
BlackBrownRed
OrangeYellowPinkBlueVioletGrayWhiteWhiteYellowOrangeYellowPinkBlueVioletGray
OrangeRed
BrownPinkGrayBlackWhite
Lead wire color Dot markingThe D-sub connector cable assembly can be orderedindividually or included in a specific manifold model No.Refer to "How to Order Manifold".
Note) Types with 15 pin are also available. See p.1.10-159 for details.
D-sub connector cable ass'y (Option) Electric characteristicsltem
noteAss'y No.
AXT100-DS25-015AXT100-DS25-030AXT100-DS25-050
1.5m3m5m
Cablelength (L)
Cable 25 coreX 24AWG
Conductorresistance
Ω/km, 20˚CVoltage limitV, 1min, AC
Insulationresistance
MΩ/km, 20˚C
Characteristic
65 or less
1000
5 or more∗ For other commercial connectors, use a 25-pin female connector made in conformity with MIL-C-24308.
Note) The min. bending radius of D-sub cableassembly is 20mm.
Cable Assembly
AXT100–DS25– Wire color table by terminal number of D-sub connector cable assembly:
How to Order Manifold
2 stations
24 stations
02
24
ManifoldPlug-in unit1
VQ1000VQ2000
12
Without cable
With cable (1.5m)
With cable (3m)
With cable (5m)
0123
Top(vertical)
Side(horizontal)US
Option
Connector location
Port size
One-touch fitting for ø3.2
One-touch fitting for ø4
One-touch fitting for ø6
One-touch fitting for ø8
M5 thread
Mixed size/with port plug
VQ1000
VQ2000
Symbol
C3C4C6C8M5CM
Cylinder ports
Cable (length)
Series
Stations
VV5Q 1 08 C6 U 11 NF
Note) Refer to p.1.10-160 for details.
Symbol
—
B
D
G1
G2
G3
J
K
N
R
S
Option
NoneCheck valve for
prevention of back pressure
DIN rail mounting
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With vacuum ejector unit
Special wiring specification
(Not double wiring)
With name plate
External pilot
Built-in silencer (Direct exhaust)
(2)
(3)
(4)
(5)
(6)
VQ1000
VQ2000
(3)
… …
The D-sub connector reduces installation labor for electrical connection.The D-sub connector (25 pin std., 15 pin option) conforms with MIL permitting use of commercial connectors with wide interchangeability.Top or side receptacle position can be selected in accordnce with the available mounting space.Max. 24 stations.
D-sub connector (25 pin)
VQ1000/2000Kit (D-sub Connector)F
Manifold Specifications
ApplicablestationsPort sizePort
location
Side
Side
Porting specifications
Max. 24
Max. 24
C3, C4, C6, M5
C4, C6, C8
VV5Q11 VV5Q21
C8
C10
A, BP, R
Series
VQ1000
VQ2000
015030050
Note 1) Insert “L” (top piping) or “B” (bottom piping) for elbow type. Example) B6 (Elbow One- touch fitting for ø6, bottom piping.)Note 2) Indicate "LM" for models with elbow fittings and mixed cylinder port sizes.Note 3) Specify “Mixed size/with port plug” by means of manifold specification form. Note 4) Refer to “Options” on p.1.10-161 for One-touch fittings in inch sizes.
Note 1) If specifying more than one option, please list alph- abetically. Example) -BRSNote 2) Models with a suffix “-B” have check valves for pre- vention of back pressure at all manifold stations. If not all stations need this check valve, specify the st- ations where check valves are installed by manifold specification form. Note 3) Specify the mounting position by means of the ma- nifold specification form.Note 4) Refer to p.1.10-152 for the details of ejector mounted styles. A combination of “J” and “N” is unavailable.Note 5) Specify the wiring by means of the manifold specif- ication form. Note 6) Indicate “R” for the valve with external pilot.
Remarks
1.10-125
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
How to Order Valve
Metal
Rubber
01
Configuration2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
12345
VQ1000VQ2000
12
Series
Seal
VQ 0 51 01 Y
Electrical Wiring Specifications
Irrespective of the valves oroptions, the internal wiring ismade double (connected toSOL. A and SOL. B) forrespective stations of the manifold. The optional specification permits mixture of single and double wiring.See p.1.10-160 for details.
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.A
SOL.ASOL.B
SOL.B
COM.
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( – )
Black
Yellow
Brown
Pink
Red
Blue
Orange
Violet
Yellow
Gray
Pink
Orange
Blue
Red
Violet
Brown
Gray
Pink
White
Gray
White
Black
Yellow
White
Orange
–
Black
–
Black
–
White
–
–
–
–
–
Black
–
White
White
White
Black
Red
Black
Red
Red
White
Red
–
Red
PolarityTerminal No. Lead wire color
D-sub cable ass'y
wire color table
Dot marking
1 station
2 station
3 station
4 station
5 station
6 station
7 station
8 station
9 station
10 station
11 station
Positive COM Negative COM
Note)
Non-locking push stylePush-locking slotted stylePush-locking lever style
Manual override–BC
100V AC (50/60Hz)200V AC (50/60Hz)110V AC (50/60Hz)220V AC (50/60Hz)
24V DC12V DC
Coil voltage123456
Indicator light and surge voltage suppressor
YesNo
–E
VV5Q11-09C6FU2···1 set-Manifold base No.∗ VQ1100-5·············2 sets-Valve No. (Stations 1 to 2)∗ VQ1200-5·············4 sets-Valve No. (Stations 3 to 6)∗ VQ1300-5·············2 sets-Valve No. (Stations 7 to 8)∗ VVQ1000-10A-1···1 set-Blank plate No. (Station 9)
How to Order Manifold Ass'y
(Example)
Write sequentially from the 1st station on the D side.When part nos. written col-lectively are complicated,specify by using a manifoldspecification form.
Specify valve and option nos. below the manifold base no.
Add prefix “∗” to parts nos. of the solenoid valves, etc.
D-sub connector kit with 3m cable
The total number of stations is tabulated starting from station one on the D side.
Pilot valve
–
H
Y
Note) Use negative COM valves for negative COM specification manifolds. (See p.1.10-160)
12 station
(1.0W)
(1.5W)
(0.5W)
Standard
High pressure
Low wattage
Note) Refer to “Options” on p.1.10- 160 and 1.10-161 for external pilot and negative COM specifications.
Note) Refer to p.1.10-122 for AC.
Symbol Specification DC AC(1)
–
–
AXT100–DS25–015030050
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-126
VQ1000/2000Kit (D-sub Connector)F
Dimensions (mm)
L1L2
(L3)(L4)
< >: AC type and TÜV approved type
265.583.5112.5123
37694125
135.5
486.5104.5125
135.5
597115
137.5148
6107.5125.5150
160.5
7118136
162.5173
8128.5146.5175
185.5
9139157
187.5198
10149.5167.5187.5198
11160178200
210.5
12170.5188.5212.5223
13181199225
235.5
14191.5209.5237.5248
15202220250
260.5
16212.5230.5250
260.5
17223241
262.5273
18233.5251.5275
285.5
19244262
287.5298
20254.5272.5300
310.5
21265283
312.5323
22275.5293.5325
335.5
23286304325
335.5
24296.5314.5337.5348
L nEquation L1=10.5n+44.5, L2=10.5n+62.5 n: Station (Max. 24)
Vacuum ejector unit style: Equation
VQ1000
Manifold F kit (Top entry connector)····SV5Q11M, #1 F kit (Side entry connector)···SV5Q11M, #2 Valve 2 position single······SV5Q11V, #9 2 position double····SV5Q11V, #10 3 position················SV5Q11V, #10
The broken lines indicate DIN rail mounting style [-D] and side entry connector [-FS].
L1=10.5n+28.7+(number of ejector units X 26.7)L2=10.5n+46.3+(number of ejector units X 26.7)L4 is L2 plus about 30.
1.10-127
Dimensions (mm)
L1L2
(L3)(L4)
285105
137.5148
3101121150
160.5
4117137
162.5173
5133153
187.5198
6149169200
210.5
7165185
212.5223
8181201225
235.5
9197217250
260.5
10213233
262.5273
11229249275
285.5
12245265300
310.5
13261281
312.5323
14277297325
335.5
15293313
337.5348
16309329350
360.5
17325345375
385.5
18341361
387.5398
19357377400
410.5
20373393
412.5423
21389409
437.5448
22405425450
460.5
23421441
462.5473
24437457
487.5498
L nEquation L1=16n+53, L2=16n+73 n: Station (Max. 24)
VQ2000 The broken lines indicate DIN rail mounting style[-D] and side entry connector [-FS].
< >: AC type and TÜV approved type
Manifold F kit (Top entry connector)····SV5Q21M, #1 F kit (Side entry connector)···SV5Q21M, #2
Valve 2 position single······SV5Q21V, #7 2 position double····SV5Q21V, #8 3 position ···············SV5Q21V, #8
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-128
MIL flat cable connector reduces installation labor for electrical connection.The connector (26 pin; 10, 16, and 20 pin option) conforms with MIL spec. permitting use of widely interchangeable commercial connectors.Top or side receptacle position can be selected in accordance with the available mounting space.Max. 24 stations.
Flat cable (26 pin)
AXT100-FC26-1 to 3
Flat cable connector assembly can be ordered individually or included in a specific manifold model no. Refer to “How toOrder Manifold”.
Flat cable connector assembly (Option)
NoteAss'y No.Cable length (L)
AXT100-FC26-1AXT100-FC26-2AXT100-FC26-3
1.5m3m5m
Cable 26 coreX 28AWG
∗ For other commercial connectors, use 26-pin type with strain relief made in conformity with MIL-C-83503.
Note) Types with 10, 16, or 20 pin are also available. See p.1.10-159 for details.
How to Order Manifold
2 stations
24 stations
02
24
ManifoldPlug-in unit1
VQ1000VQ2000
12
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
0123
Top (vertical)Side (horizontal)
US
Connector locationCable (length)
Series
Stations
Cable Assembly
VV5Q 1 08 C6 U 11 NP
Note) Refer to p.1.10- 160 for details.
VQ1000/2000Kit (Flat Cable Connector)P
Manifold Specifications
Applicablestations
Port sizePortlocation
Side
Side
Porting specifications
Max. 24
Max. 24
C3, C4, C6, M5
C4, C6, C8
C8
C10
A, BP, R
Series
VQ1000
VQ2000
VV5Q11 VV5Q21
OptionSymbol Option VQ1000 VQ2000
–
B
D
G1
G2
G3
J
N
R
S
None
Check valve forprevention of back press.
DIN rail mounting
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With vacuum ejector unit
Special wiring specification (Not double wiring)
With name plate
External pilot
Built-in silencer (Direct exhaust)
K
(2)
(3)
(4)
(5)
(6)
Note 1) If specifying more than one option, please list alph- abetically. Example) -BRSNote 2) Models with a suffix “-B” have check valves for pre- vention of back pressure at all manifold stations. If not all stations need this check valve, specify the st- ations where check valves are installed by manifold specification form. Note 3) Specify the mounting position by means of the ma- nifold specification form.Note 4) Refer to p.1.10-152 for the details of ejector mounted styles. A combination of “J” and “N” is unavailable.Note 5) Specify the wiring by means of the manifold specif- ication form.
VQ1000
VQ2000
SymbolC3C4C6C8M5CM
Cylinder portsPort size
One-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6One-touch fitting for ø8
M5 threadMixed size/with port plug (3)
Note 1) Insert “L” (top piping) or “B” (bottom piping) for elbow type.
Example) B6 (Elbow One–touch fittings for ø6, bottom piping.)Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Specify “Mixed size/with port plug” by means of manifold specification form. Note 4) Refer to “Options” on p.1.10-161 for One-touch fittings in inch sizes.
VV5Q11
VV5Q21
The total number of stations is tabulated
starting from station one on the D side.
… …
Remarks
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
How to Order Valve
Metal
Rubber
01
Configuration2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
12345
VQ1000VQ2000
12
Series
Seal
VQ 0 51 01 Y
Electrical Wiring Specifications
Irrespective of the valves or options, the internal wiring is made double (connected to SOL.A and SOL.B) for respective stations of the manifold. The optional specification permits mixture of single and double wiring. See p.1.10-160 for details.
Note) Use negative COM valves for negative COM specification manifolds. (See p.1.10-160)
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.A
SOL.ASOL.B
SOL.B
COM.
1234567891011121314151617181920212223242526
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( – )
( – )
Terminal No. PolarityFlat cable connector
1 station
PositiveCOM
Electrical Wiring Specifications NegativeCOM
(1)
100V AC (50/60Hz)110V AC (50/60Hz)
24V DC12V DC
Coil voltage1356
Note) Refer to “Options” on p.1.10-160 and 1.10-161for external pilot and negative CO-M specifications.
Indicator light and surge voltage suppressor
YesNo
–E
COM.
How to Order Manifold Ass'y
Specity valve and option nos. below the manifoldbase no.
(Example)
Write sequentially from the 1st station on the D side.When part Nos. written col-lectively are complicated,specify by using a manifoldspecification form.
Flat cable kit with 3m cable
2 station
3 station
4 station
5 station
6 station
7 station
8 station
9 station
10 station
11 station
12 station
Non-locking push stylePush-locking slotted stylePush-locking lever style
Manual override–BC
Add prefix “∗” to parts nos. of thesolenoid valves, etc.
Pilot valve
Note 1) Refer to p.1.10-122 for AC.
–
H
Y
(1.0W)
(1.5W)
(0.5W)
Standard
Symbol Specification DC AC(1)
–
–
VV5Q11-09C6PU2··1 set –Manifold base No.∗ VQ1100-5··············2 sets–Valve No. (Stations 1 to 2)∗ VQ1200-5··············4 sets–Valve No. (Stations 3 to 6)∗ VQ1300-5··············2 sets–Valve No. (Stations 7 to 8)∗ VVQ1000-10A–1···1 set –Blank plate No. (Station 9)
High pressure
Low pressure
1.10-129
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-130
VQ1000/2000Kit (Flat Cable Connector)P
Dimensions (mm)
L1
L2
(L3)
(L4)
265.578.5112.5123
37689125
135.5
486.599.5125
135.5
597110
137.5148
6107.5120.5150
160.5
7118131
162.5173
8128.5141.5175
185.5
9139152
187.5198
10149.5162.5187.5198
11160173200
210.5
12170.5183.5212.5223
13181194225
235.5
14191.5204.5225
235.5
15202215
237.5248
16212.5225.5250
260.5
17223236
262.5273
18233.5246.5275
285.5
19244257
287.5298
20254.5267.5287.5298
21265278300
310.5
22275.5288.5312.5323
23286299325
335.5
24296.5309.5337.5348
L n
VQ1000 The broken lines indicate DIN rail mounting style[-D] and side entry connector [-PS].
Equation L1=10.5n+44.5, L2=10.5n+62.5 n: Station (Max. 24)
Vacuum ejector unit style: Equation L1=10.5n+28.7+(number of ejector units X 26.7)L2=10.5n+41.3+(number of ejector units X 26.7)L4 is L2 plus about 30.
< >: AC type and TÜV approved type
Manifold P kit (Top entry connector)····SV5Q11M, #3 P kit (Side entry connector)···SV5Q11M, #4
Valve 2 position single ····SV5Q11V, #9 2 position double····SV5Q11V, #10 3 position················SV5Q11V, #10
1.10-131
285100125
135.5
3101116150
160.5
4117132
162.5173
5133148175
185.5
6149164
187.5198
7165180
212.5223
8181196225
235.5
9197212
237.5248
10213228
262.5273
11229244275
285.5
12245260
287.5298
13261276300
310.5
14277292
312.5323
15293308
337.5348
16309324350
360.5
17325340
362.5373
18341356
387.5398
19357372400
410.5
20373388
412.5423
21389404425
435.5
22405420450
460.5
23421436
462.5473
24437452475
485.5
L n
VQ2000 The broken lines indicate DIN rail mounting style [-D] and side entry connector [-PS].
Equation L1=16n+53, L2=16n+68 n: Station (Max. 24)
< >: AC type and TÜV approved type
Manifold P kit (Top entry connector)····SV5Q21M, #3 P kit (Side entry connector)···SV5Q21M, #4 Valve 2 position single ····················SV5Q21V, #7 2 position double···················SV5Q21V, #8 3 position·······························SV5Q21V, #8
Dimensions (mm)
L1
L2
(L3)
(L4)
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-132
Terminal block for power supply equipped with a 20 pin flat cableconnection for rationalized connection of valves.Solenoid valves and power supply can be connected by the samecable to a specific output unit that requires power supply from theoutput section to the internal circuit. (Sl unit)Max. 16 stations
Flat cable(20 pin)
AXT100-FC20-1 to 3
Flat cable connector assembly can be ordered individually or includedin a specific manifold model no. Refer to “How to Order Manifold”.
NoteAss'y NoCable length (L)
1.5m3m5m
Cable 20 coreX 28AWG
∗ For other commercial connectors, use 20 pin type with strain relief made in conformity with MIL-C-83503.
How to Order Manifold
2 stations
16 stations
02
16(1)
ManifoldPlug-in unit1
VQ1000VQ2000
12
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
0123
VQ1000VQ2000
–U
Connector location(Top entry)
Cable (length)Series
Stations
Cable Assembly
VV5Q 1 08 C61 NG
… …
VQ1000/2000Kit (Flat Cable Connector with Terminal Block)G
Manifold Specifications
Applicablestations
Port sizePortlocation
Side
Side
Porting specifications
Max.16
Max.16
C3, C4, C6, M5
C4, C6, C8
C8
C10
A, BP, R
Series
VQ1000
VQ2000
VV5Q11 VV5Q21
The total number of stations is tabulated starting from station one on the D side.
Flat cable connector assembly (Option)
AXT100-FC20-1AXT100-FC20-2AXT100-FC20-3
Refer to p.1.10-160 for details.
Note 1)
OptionSymbol Option RemainsVQ1000 VQ2000
–
B
D
G1
G2
G3
J
N
R
S
None
Check valve forprevention of back press.
DIN rail mounting
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With vacuum ejector unit
Special wiring specification(Not double wiring)
With nameplate
External pilot
Built-in silencer (Direct-exhaust)
K
(2)
(3)
(4)
(6)
(5)
VQ1000
VQ2000
Symbol
C3C4C6C8M5CM
Cylinder portsPort size
One-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6One-touch fitting for ø8
M5 threadMixed size/with port plug
(3)
Note 1) Insert “L” (top piping) or “B” (bottom piping) for elbow type. Example) B6 (Elbow One-touch fittings for ø6, bottom piping.)Note 2) Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Note 3) Specify “Mixed size/with port plug” by means of manifold specification form. Note 4) Refer to “Options” on p.1.10-161 for One-touch fittings in inch sizes.
Note 1) If specifying more than one option, please list alph- abetically. Example) -BRSNote 2) Models with a suffix “-B” have check valves for pre- vention of back pressure at all manifold stations. If not all stations need this check valve, specify the st- ations where check valves are installed by manifold specification form. Note 3) Specify the mounting position by means of the ma- nifold specification form.Note 4) Refer to p.1.10-152 for the details of ejector mounted styles. A combination of “J” and “N” is unavailable.Note 5) Specify the wiring by means of the manifold specif- ication form. Note 6) Indicate “R” for the valve with external pilot.
1.10-133
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
How to Order Valve
01
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center
12345
VQ1000VQ2000
12
VQ 0 51 01 Y
Connector Ass'y
Irrespective of the valves oroptions, the internal wiringis made double (connectedto SOL. A and SOL. B) forrespective stations of themanifold.The optional specificationpermits mixture of singleand double wiring. See p.1.10-160 for details.
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.B
201816141210861917151311975
3.4
1.2
-+
Electrical circuit diagram (Shown as standard for all double solenoid connection.)
DC24V
Non-locking push stylePush-locking slotted stylePush-locking lever style
Manual override–BC
DC24V5
Note) Refer to “Options” on p.1.10-161 for external pilot specifications.
YesNo
–E
1 set –Manifold base No.4 sets–Valve No. (Stations 1 to 4)1 set –Valve No. (Stations 5)3 sets–Valve No. (Stations 6 to 8)
How to Order Manifold Ass'y
Specify valve and option nos. below the manifoldbase no.
(Example)
Write sequentially from the1st station on the D side. When part nos. written col-lectively are complicated,
specify by using a manifold speci-fication form.
Add prefix “∗” to partsnos. of the solenoidvalves, etc.
Flat cable with power supply terminal block and 3m cableVV5Q11-08C6G2···∗ VQ1100-5············∗ VQ1200-5············∗ VQ1300-5············
Standard
Highpressure
Lowwattage
Pilot valve
–
H
Y
DC
(1.0W)
(1.5W)
(0.5W)
Terminal No.
1 station
2 stations
3 stations
4 stations
5 stations
6 stations
7 stations
8 stations
Configuration
Series
MetalRubber
Seal Symbol Specification
Coil voltage
Indicator light and surge voltage suppressor
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-134
Kit (Flat Cable Connector with Terminal Block)VQ1000/2000G
Dimensions (mm)
L1L2
(L3)(L4)
266.584
112.5123
377
94.5125
135.5
487.5105125
135.5
598
115.5137.5148
6108.5126150
160.5
7119
136.5162.5173
8129.5147175
185.5
9140
157.5187.5198
10150.5168
187.5198
11161
178.5200
210.5
12171.5189
212.5223
13182
199.5225
235.5
14192.5210
237.5248
15203
220.5250
260.5
16213.5231
262.5273
L n
VQ1000 The broken lines and dimensions in parenthsesindicate DIN rail mounting style [-D].
Equation L1=10.5n+45.5, L2=10.5n+63 n: Station (Max. 16)
Vacuum ejector unit style: Equation L1=10.5n+29.7+(number of ejector units X 26.7)L2=10.5n+46.8+(number of ejector units X 26.7)L4 is L2 plus about 30.
ManifoldG kit(Top entry connector)…SV5Q11M, #5
Valve2 position single ……SV5Q11V, #92 position double……SV5Q11V, #103 position ……………SV5Q11V, #10
1.10-135
Dimensions (mm)
L1L2
(L3)(L4)
285
119150
160.5
3101135
162.5173
4117151175
185.5
5133167
187.5198
6149183
212.5223
7165199225
235.5
8181215
237.5248
9197231
262.5273
10213247275
285.5
11229263
287.5298
12245279300
310.5
13261295325
335.5
14277311
337.5348
15293327350
360.5
16309343
362.5373
L n
VQ2000 The broken lines indicate DIN rail mounting style [-D].
Equation L1=16n+53, L2=16n+87 n: Station (Max. 16 stations)
Vacuum ejector unit style: Equation L1=10. 5n+29.7+(number of ejector units X 26.7)L2=10. 5n+46.8+(number of ejector units X 26.7)L4 is L2 plus about 30.
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-136
This kit has a small terminal box inside a junction box. The electrical entry port VQ1000: G(PF)1/2, VQ2000: G(PF)3/4 permits connection of conduit fittings. Max. 24 stations.Enclosure: dust-resistant/jet–proof type (IP65) available. (Series VQ2000)
Open the terminal block cover for wire connection.
How to Order Manifold
ManifoldPlug-in unit1
VQ1000VQ2000
12
Series
Stations
Terminal Block Connection
Electrical Wiring Specifications/VQ1000
Sequence 1. How to remove terminal block coverLoosen the screws on the terminal block cover and open it in the direction shown by the arrow. The cover can then be removed from the terminal block.
Sequence 3. How to replace terminal block cover
Hook groove “b” on shaft “a” and close the
cover. Then tighten the screws.
Sequence 2. Wire connectionThe diagram on the left shows the terminal block wiring schematic.All stations are provided with double solenoid wiring.Insert each lead wire into the terminal opening and tighten the screw directly above.
VV5Q 1 008 C61 NT
VQ1000/2000Kit (Terminal Box)T
Manifold Specifications
ApplicablestationsPort sizePort
location
SideSide
Porting specifications
Max. 24 Max. 20
C3, C4, C6, M5C4, C6, C8
C8C10
A, BP, RSeries
VQ1000VQ2000
2 stations
24 stations
02
24
… …
Note) VQ2000: Max. 20 stations.
Note)
Note) Refer to “Options” on p.1.10-160 for negative COM specifications.
Irrespective of the valves oroptions, the internal wiring is made double (connected to SOL. A and SOL. B) for res-pective stations of the mani-fold. The optional specifica-tion permits mixture of single and double wiring. See p.1.10-160 for details.Note) Use negative COM valves for negative COM specification manifolds. See p.1.10-160 for details.
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
SOL.A
SOL.A
SOL.B
SOL.B
COM.
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
11A
11B
12A
12B
COM
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(–)
COM (+) (–)
Terminal No. Polarity
1 station
2 stations
3 stations
4 stations
5 stations
6 stations
7 stations
8 stations
9 stations
10 stations
11 stations
12 stations
PositiveCOM
(1)
NegativeCOM
The quantity of terminal blocks used depends on the number of manifold stations:
Qty.of terminal blocks
2 rows
3 rows
Manifold
2 to 8 stations
9 to 12 stations
VV5Q11VV5Q21
The total number of stations is tabulated starting from station one on the D side.
COM.
OptionSymbol Option RemarksVQ1000 VQ2000
–
B
D
G1
G2
G3
J
N
R
S
W
None
Check valve forprevention of back press.
DIN rail mounting
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With vacuum ejector unit
Special wiring specification (Not double wiring)
With name plate
External pilot
Built-in silencer (Direct exhaust)
K
(2)
(3)
(4)
(6)
(5)
Note 1) Note 2)
Note 3) Note 4)
Note 5) Note 6)
If specifying more than one option, please list alphabetically. Example) -BRSModels with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. If not all stations need this check valve, specify thestations where check valves are installed by a manifold specification form. Specify the mounting position by means of the manifold specification form.Refer to p.1.10-152 for the details of ejector mounted styles.A combination of “J” and “N” is unavailable.Specify the wiring by means of the manifold specification form. Indicate “R” for the valve with external pilot.
VQ1000
VQ2000
SymbolC3C4C6C8M5CM
Cylinder portsPort size
One-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6One-touch fitting for ø8
M5 threadMixed size/with port plug
Note 1)
Note 2)
Note 3)
Note 4)
(3)
IP65 available
Insert “L” (top piping) or “B” (bottom piping) for elbow type.Example) B6 (Elbow One-touch fittings for ø6, bottom piping.)Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Specify “Mixed size/with port plug” by means of manifold specification form. Refer to “Options” on p.1.10-161 for One-touch fittings in inch sizes.
IP65
1.10-137
VV5Q21Dust resistant/Jet proof type
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
How to Order Valve
Metal
Rubber
01
Configuration2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
12345
VQ1000
VQ2000
12
Series
Seal
VQ 0 51 01 Y
Special Wiring Specifications/VQ2000
Note) Use negative COM valves for negative COM specification manifolds.See p1.10-160 for details.
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.B
COM.
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(–)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+) (–)
PolarityTerminal No.
1 station
PositiveCOM
Note)
Non-locking push style Push-locking slotted stylePush-locking lever style
Manual override–BC
100V AC (50/60Hz)110V AC (50/60Hz)
24V DC12V DC
Coil voltage1356
Note) Refer to “Options” on p.1.10-160 and 1.10-161 for external pilot and negative COM specifications.
Indicator light and surge voltage suppressorYesNo
–E
……………………………………………………
1 set—Manofold base No.2 sets—Valve No. (Stations 1 to 2)4 sets—Valve No. (Stations 3 to 6)1 set—Valve No. (Station 7)1 set—Blank plate No. (Station 8)
How to Order Manifold Ass’y
Specify valve and option nos. below the mani-fold base no.
(Example)
Write sequentially from the 1st station on the D side. When part nos. written collectively
are complicated, specify by using a manifold spec-ification form.
Add prefix “∗” toparts nos. of thesolenoid valves, etc.
Terminal box kitVV5Q11-08C6T0 ∗ VQ1100-5 ∗ VQ1200-5 ∗ VQ1300-5 ∗ VVQ1000-10A–1
The total number of stations is tabulated starting from station one on the D side.
Note 1) Refer to p.1.10-122 for AC.
Note) VQ2000 only.
Note)
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC AC
(1.0W)
(1.5W)
(0.5W)
–
–
(1)
Enclosure–W
2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations
10 stations
NegativeCOM
Dust proof Dust tight/Jet proof (IP65)
Irrespective of the valves or opti-ons, the internal wiring is made double (connected to SOL. A and SOL. B) for respective stations of the manifold. The optional specifi-cations permits mixture of single and double wiring. See p.1.10-160 for details.
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-138
VQ1000/2000Kit (Termnal Box)T
Dimensions (mm)2
66.5126150
160.5
377
136.5162.5173
487.5147175
185.5
598
157.5187.5198
6108.5168
187.5198
7119
178.5200
210.5
8129.5189
212.5223
9140
199.5225
235.5
10150.5210
237.5248
11161
220.5250
260.5
12171.5231
262.5273
13182
241.5262.5273
14192.5252275
285.5
15203
262.5287.5298
16213.5273300
310.5
17224
283.5312.5323
18234.5294325
335.5
19245
304.5325
335.5
20255.5315
337.5348
21266
325.5350
360.5
22276.5336
362.5373
23287
346.5375
385.5
24297.5357
387.5398
L n
VQ1000 The broken lines and dimensions in parentheses indicate DIN rail mounting style [-D].
L1L2
(L3)(L4)
Vacuum ejector unit style: Equation
Equation L1=10.5n+45.5, L2=10.5n+105 n: Station (Max. 24)
< >: AC type and TÜV approved type
Manifold T kit…SV5Q11M, #6Valve 2 position single …SV5Q11V, #9 2 position double…SV5Q11V, #10 3 position …………SV5Q11V, #10
L1=10.5n+29.7+(number of ejector units X 26.7)L2=10.5n+88.8+(number of ejector units X 26.7)L4 is L2 plus about 30.
1.10-139
2150.5163
187.5198
3166.5179200
210.5
4182.5195225
235.5
5198.5211
237.5248
6214.5227250
260.5
7230.5243
262.5273
8246.5259
287.5298
9262.5275300
310.5
10278.5291
312.5323
11294.5307
337.5348
12310.5323350
360.5
13326.5339
362.5373
14342.5355375
385.5
15358.5371400
410.5
16374.5387
412.5423
17390.5403425
435.5
18406.5419450
460.5
19422.5435
462.5473
20438.5451475
485.5
L n
VQ2000 The broken lines and dimensions in parentheses indicate DIN rail mounting style [-D].
Dimensions (mm)
L1L2
(L3)(L4)
Equation L1=16n+118.5 L2=16n+131 n: Station (Max. 20)
< >: AC type and TÜV approved type
Vacuum ejector unit style: Equation L1=10.5n+29.7+(number of ejector unit X 26.7)L2=10.5n+88.8+(number of ejector unit X 26.7)L4 is L2 plus about 30.
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-140
Direct electrical entry. Models with one or more stations are available.P (SUP) and R (EXH) ports are provided on one side for further space savings.Max. 8 stations.Enclosure: dust resistant/Jet proof style (IP65) available. (Series VQ2000)
Irrespective of the valve mounted, three lead wires are attachedto each station. The red wire is for COM connection.
Use any of the following cable lead wire ass'ys to change the lead wire length:
Part No.Lead wire length (L)VVQ1000-84A-6-∗VVQ1000-84A-15-∗VVQ1000-84A-30-∗
0.6m1.5m3m
∗ No.of stations 1 to 8
How to Order Manifold
01
08
1
VQ1000VQ2000
12
012
Option
Cable (length)
Wiring Specifications/Positive COM
VV5Q 1 06 C61 1 NL
Note) Refer to “Options” on p.1. 10-160 for negative COM specifications.
VQ1000/2000Kit (Lead Wire Cable)L
VQ1000
VQ2000
Symbol
–
B
D
G1
G2
G3
JN
R
S
W
None
Check valve forprevention of back press.
DIN rail mounting
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With vacuum ejector unit
With name plate
External pilot capable
Built-in silencer (Direct exhaust)
VQ2000
With cable (0.6m)With cable (1.5m)With cable (3m)
Single solenoid Double solenoid
COM (+)
SOL.A
SOL.B
COM (+)
(–)
(–)
(–)
(–)
SOL.A
SOL.B
Black
Lead wire color Lead wire color
Red
White
Black
Red
White
The total number of stations is tabulated starting from station one on the D side.
Note 1)
Note 2)
Note 3)
Note 4)
Note 5)
Cable lead wire assembly with connector
IP65 available
Manifold Specifications
ApplicablestationsPort sizePort
location
Side
Side
Porting specifications
Max. 8
Max. 8
C3, C4, C6, M5
C6, C8
C8
C10
A, BP, R
Series
ManifoldPlug-in unit
Series
Stations1 stations
8 stations
……
VQ1000
VQ2000
Symbol
C3C4C6C8M5CM
Cylinder portsPort size
One-touch fitting for ø3.2
One-touch fitting for ø4
One-touch fitting for ø6
One-touch fitting for ø8
M5 thread
Mixed size/with port plug (3)
Note 1)
Note 2)
Note 3)
Note 4)
Insert “L” (top piping) or “B” (bottom piping) for elbow type. (VQ1000 only)Example) B6 (Elbow One-touch fittings for ø6, bottom piping.)Indicate “LM” for models with elbow fittings and mixed cylinder port sizes.Specify “Mixed size/with port plug” by means of manifold specification form. Refer to “Options” on p.1.10-161 for One-touchfittings in inch sizes.
Option Remarks
(2)
(3)
(3)
(3)
(4)
(5)
VQ1000
If specifying more than one option, please list alpha-betically. Example) -BRSModels with a suffix “-B” have check valves for pre-vention of back pressure at all manifold stations. If not all stations need this check valve, specify the stations where check valves are installed by a ma-nifold specification form. Specify the mounting position by means of the ma-nifold specification form.Refer to p.1.10-152 for the details of ejector mounted styles. A combination of “J” and “N” is unavailable.Indicate “R” for the valve with external pilot.
IP65
1.10-141
VV5Q21Dust tight/Jet proof style
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
……………………………………………………
How to Order Valve
Metal
Rubber
01
Configuration2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
12345
VQ1000
VQ2000
12
Series
Seal
VQ 0 51 01 Y
Non-locking push stylePush-locking slotted stylePush-locking lever style
Manual override–BC
100V AC(50/60Hz)200V AC (50/60Hz)110V AC (50/60Hz)220V AC (50/60Hz)
24V DC12V DC
123456
Note) Refer to “Options” on p.1.10-160 and 1.10-161 for external pilot and negative COM specifications.
Note) Use negative COM type valves for negative COM specification manifolds. See p.1.10-160 for further details.
YesNo
–E
Irrespective of the valve mounted, three lead wires are attached to each station. The black wire is for COM connection.
Cable lead wire assembly with connectorPart No.
0.6m1.5m3m
∗ No. of stations 1 to 8
Wiring Specifications/Negative COM (Options)
Lead wire length (L)VVQ1000-84AN-6-∗VVQ1000-84AN-15-∗VVQ1000-84AN-30-∗
Single solenoid Double solenoid
COM
SOL.A
SOL.B
COM (–)
(+)
(+)
SOL.A
SOL.B
Red
Lead wire color
Black
White
(–)
(+)
(+)
Red
Lead wire color
Black
White
1 set–Manifold base No.2 sets–Valve No. (Stations 1 to 2)2 sets–Valve No. (Stations 3 to 4)1 set–Valve No. (Station 5)1 set–Blank plate No. (Station 6)
How to Order Manifold Ass'y
Specify valve and option nos. below the mani-fold base no.
(Example)
Write sequentially from the 1st station on the D side.When part nos. written collectively
are complicated, specify by using manifold specifi-cation form.
Add prefix “∗ ” to parts nos.of the solenoidvalves, etc.
With lead wire kit/cable (3m)VV5Q11-06C6L2 ∗ VQ1100-5 ∗ VQ1200-5 ∗ VQ1300-5 ∗ VVQ1000-10A-1
Note) Refer to p.1.10-122 for AC type.
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC AC
(1.0W)
–
–
(1.5W)
(0.5W)
Note) VQ2000 only.
EnclosureDust-proof
IP65–W
Coil voltage
Indicator light and surge voltage suppressor
(1)
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-142
VQ1000/2000Kit (Lead Wire Cable)L
139
48.575
85.5
249.559
87.598
360
69.587.598
470.580100
110.5
581
90.5112.5123
691.5101125
135.5
7102
111.5137.5148
8112.5122150
160.5
L n
VQ1000 The broken lines indicate DIN rail mounting style [-D].
Dimensions (mm) Equation L1=10.5n+28.5, L2=10.5n+38 n: Station (Max. 8 stations)
Vacuum ejector unit style: Equation
L1L2
(L3)(L4)
ManifoldL kit………SV5Q11M, #7
Valve2 position single ………SV5Q11V, #92 position double………SV5Q11V, #103 position ………………SV5Q11V, #10
< >: AC type and TÜV approved type
L1=10.5n+28.5+(number of ejector units X 26.7)L2=10.5n+38+(number of ejector units X 26.7)L4 is L2 plus about 30.
1.10-143
26779100
110.5
15163
87.598
38395125
135.5
499111
137.5148
5115127150
160.5
6131143
162.5173
7147159
184.5198
8163175200
210.5
L n
VQ2000 The broken lines indicate DIN rail mounting style [–D].
Dimensions (mm)
L1L2
(L3)(L4)
Manifold L kit…………SV5Q21, #5Valve 2 position single…SV5Q21, #7 2 position double…SV5Q21, #8 3 position …………SV5Q21, #8
< >: AC type and TÜV approved type
Equation L1=16n+35, L2=16n+47 n: Station (Max. 8 stations)
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 1000/2000 Plug-in UnitBase Mounted
Stations are sequentially numbered from the D side.
Irrespective of the valves or options, the internal wiring is made double
(connected to SOL. A and SOL. B) for respective staions of the manifold. The optional specification permits mixture of single and double wiring. See p.1.10-160 for details.
How to Order Manifold
2 stations
16 stations
02
16
ManifoldPlug-in unit1
VQ1000VQ2000
12
Option
VQ1000
VQ2000
Symbol
C3C4C6C8M5CM
Cylinder ports
Dust proof style(–XP)
Style
Series
Stations
VV5Q 1 08 C61 A XPNS
……
Note 1) Refer to p.1.10- 160 for details.
VQ1000/2000Kit (Serial Transmission Unit)S
Manifold Specifications
ApplicablestationsPort sizePort
location
Side
Side
Porting specifications
Max.16
Max.16
C3, C4, C6, M5
C4, C6, C8
C8
C10
A, BP, R
Series
VQ1000
VQ2000
Symbol Option VQ1000 VQ2000
–
B
D
G1
G2
G3
J
N
R
S
W
None
Check valve for prevention of back pressure
DIN rail mounting
1set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With vacuum ejector unit
Special wiring specification
(Not double wiring)
With name plate
External pilot
Built-in silencer (Direct-exhaust)
K
(2)
(3)
(4)
(6)
(5)
Port sizeOne-touch fitting for ø3.2
One-touch fitting for ø4
One-touch fitting for ø6
One-touch fitting for ø8
M5 thread
Mixed size/with port plug
Suffix “-XP” for the dust proof SI units.
VV5Q11 VV5Q21
Note 1)
Note 2)
Note 3)
Note 4)
Note 5)Note 6)Note 7)
If specifying more than one option, please list alphabetically. Example) –BRSModels with a suffix “–B” have check valves for prevention of back pressure at all manifold sta-tions. If not all stations need this check valve, specify the stations where check valves are in-stalled by manifold specification form. Specify the mounting position by means of the manifold specification form.Refer to p.1.10-152 for the details of ejector mounted styles. A combination of “J” and “N” is unavailable.Specify wiring by the manifold specification form.Indicate “R” for the valve with external pilot.A combination of “W” and “XP” is unavailable.
(3)
Note 1)
Note 2)
Note 3)
Note 4)
Note 1) The general type requires a transmission unit on CPU side.Note 2) SBB kit is usable only for VQ2000 dust tight/ jet proof style (IP65).
OAB
CDEF1GHJ1J2KQR1R2V
Without SI unitWith general type, Series EX300
SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)
SI unit for MELSECNET/MINI-S3 Data Link System(2 power supply lines) (Mitsubishi Electric)
SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)
SI unit for MEWNET-F System (Matsushita Electric Works Ltd.)SI unit for 16 point Uni-wire System (NKE)
SI unit for Remote I/O (RIO) System (Allen-Bradley Co.)SI unit for 16 point Uni-wire H System (NKE)SI unit for 16 point S-LINK System (Sunx)SI unit for 8 point S-LINK System (Sunx)SI unit for T-LINK Mini System (Fuji Electric)SI unit for Device Net and Compo Bus/D (OMRON)
SI unit for 16 point Compo Bus/S (OMRON)SI unit for 8 point Compo Bus/S (OMRON)SI unit for CC-LINK (Mitsubishi Electric)
Max. 16 stations
Max. 16 stations
Max. 8Max. 16
Item
External power supply
Specifications
24VDC+10%, –5%
Current consumption(Internal unit)
SA, SB, SBB, SD, SE, SF, SM, SG, SJ,SK, SQ, SR, SV: 0.1A SC: 0.3A
SA applicable to Series EX300
SB applicable to MELSECNET/MINI-S3 Data Link
(Mitsubishi Electric)
T unit Can be connected with PLC I/O card for serial transmission.
EX300-TMB1…For models of Mitsubishi Electric Corp.EX300-TTA1…For models of OMRON Corp.EX300-TFU1…For models of Fuji Electric Company Ltd.EX300-TOO1…For general models
∗ Up to 32 points per unit.16 outputs.
Master station: PLC made by Mitsubishi Electric Corp. Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 ∗ Max. 64 stations, connected to remote I/O stations (Max. 512 points).16 outputs, 2 stations occupied.
LED namePOWER
RUN
RD
SD
ERR.
DetailsLighting when power is turned ON
Lighting during data receptionLighting during data transmission
LED name
RUN/ERROR
TRD
Details
Lighting during data reception
Nam
e o
f te
rmin
al b
lock (
LE
D)
No
te
SDA SDB SG RDA RDB FG24V 0V
POWER RUN SD RD ERR
STATION NO.
ù10 ù1
24V 0V S1 S2 SG R1 R2 FG
RUNERR
TRD
ADDRESS NO.
IP65 available
BB
Max. 8
The serial transmission system minimizes wire mass and wire connection labor and promotes space savings.The system comes in SA (general for small scale system) for equipment with a small number of I/O points, or 32 points max., SB (applicable to Mitsubishi Electric models) for controlling 512 I/O points max., SC (applicable to OMRON models), SD (applicable to Sharp models: 504 points max.), SF (applicable to NKE models: 128 points max.), SJ (applicable to Sunx models), SK (applicable to Fuji Electric models), SQ (applicable to OMRON’s Compo Bus/D), and SR (applicable to OMRON’s Compo Bus/S).Max. 16 stations. (Specify a model with 9 to 16 stations by using a manifold specification form.)Enclosure: dust-resistant/jet-proof style (IP65) available (Series VQ2000)
Insert “L” (top piping) or “B” (bottom piping) for elbow type. (VQ1000 only) Example) B6 (Elbow One-touch fittings forø6, bottom piping.)Specify as “LM” for models with elbow fittings and mixed cylinder port sizes.Specify “Mixed size/with port plug” by means of manifold specification form. Refer to “Options” on p.1.10-161 for One-touch fittings in inch sizes.
Lighting when reception data error occurs.Light turns off when the error is corrected.
Enclosure: IP65(Except for SE and SG)
Blinking when received data is normal; Lighting when data is abnormal
Lighting when data transmission with the master station is normal
(2)
(1)
(3)
1.10-144
1.10-145
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
How to Order Valve
MetalRubber
01
Configuration12345
VQ1000VQ2000
12
Series
Seal
VQ 0 51 01 Y
Sl unit output and coil numbering
<Wiring example 1>
Double wiring (Standard)
Sl unit output No.
<Wiring example2>
Non-locking push stylePush-locking slotted stylePush-locking lever style
Manual override–BC
24V DC/With indicator light and surge voltage suppressor
Coil voltage
5
Note) Refer to “Options” on p.1.10-160 and 1.10-161 for external pilot and negative COM specifications.
Sl u
nit
Sl u
nit
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Dou
ble
Stations Stations1 2 3 4 5
A B A B A Void A Void A B
0 1 3 4 52 6 7 8 9
Single/Double mixed wiring (Option)
Sl unit output No.
Mixed wiring is optional. Use the manifold specification form to specify.
1 2 3 4 5
A B A B A A A B
1 2 3 6 70 4 5
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center
……………………………………………………
1 set–Manifold base No.2 sets–Valve No. (Stations 1 to 2)4 sets–Valve No. (Stations 3 to 6)1 set–Valve No. (Station 7)1 set–Blanking plate No. (Station 8)
How to Order Manifold Ass'y
Specify valve and option nos. below the mani-fold base no.
(Example)
Write sequentially from the 1ststation on the D side. When part nos. written collectively
are complicated,specify by using amanifold specifica-tion form.
Add prefix “∗” to parts nos. of the solenoid valves, etc.
Serial transmission unit kitVV5Q11–08C6SA ∗ VQ1100–5 ∗ VQ1200–5 ∗ VQ1300–5 ∗ VVQ1000–10A–1
Specification
Standard
High pressure
Lowwattage
Pilot valveSymbol
–
DC
(1.0W)
(1.5W)
(0.5W)
H
Y
SC applicable toSYSBUS Wire System
(OMRON)
SD applicable to Satellite I/O Link System
(Sharp)
Master station unit: OMRON's PLC SYSMAC Series C (CV) C500-RM201, C200H-RM201 ∗ Max. 32 units, transmission terminal connected (Max. 512 points)16 outputs
Master station unit: Sharp's PLC New Satellite Series W ZW-31LM New Satellite Series JW JW-23LM, JW-31LM ∗ Max. 31 units, I/O slave stations connected (Max. 504 points)16 outputs
LED namePOWER
RUN
DetailsIt lights when power is turned ON.
It lights when power is turned ON slave stations are in normal operation.
LED name
RUN
Details
Nam
e o
f te
rmin
al b
lock
(LE
D)
No
te
T/RERR
It blinks when transmission is normal.It lights when transmission is abnormal. ERROR It lights when slave station switch setting is abnormal, communication is
abnormal, master station's PLC is at rest, and slave station unit is out of order.
R.SETHOLD
It lights when control input is made for the master station.
L1 L2 SG L1 L2 SG24V 0V
POWER RUN SD RD ERR
STATION NO.
ù10 ù1
24V 0V + – + – FG
RUNERR
TRD
ADDRESS NO.
Note) VQ2000 only.
EnclosureDust-proof
Dust resistant/Jet proof (IP65) (1)
–W
It lights when transmission is normal and PLC is in the operation mode.
VV5Q21Dust-resistant/ jet-proof style (–W)
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-146
VQ1000/2000Kit (Serial Transmission Unit)S
265.593.5125
135.5
376
104125
135.5
486.5
114.5137.5148
597
125150
160.5
6107.5135.5162.5173
7118146175
185.5
8128.5156.5187.5198
9139167
187.5198
10149.5177.5200
210.5
11160188
212.5223
12170.5198.5225
235.5
13181209
237.5248
14191.5219.5250
260.5
15202230250
260.5
16212.5240.5262.5273
L nEquation L1=10.5n+44.5, L2=10.5n+72.5 n: Station (Max.16)
Dustproof SI unit: L5=10.5n+97 L6=L3+25, L7=L4+25
Note) Manifolds with SI unit for Matsushita’s MEWNET FP and Allen Bradley Co.’s model are the same with L5, L6 and L7 dimensions of dust-proof SI unit.
VQ1000 The broken lines indicate DIN rail mounting style [–D].
Dimensions (mm)
L1L2
(L3)(L4)
Vacuum ejector unit style: Equation
ManifoldS kit………SV5Q11M, #8
Valve2 position single …SV5Q11V, #92 position double…SV5Q11V, #103 position …………SV5Q11V, #10
L1=10.5n+28.7+(number of ejector units X 26.7)L2=10.5n+56.3+(number of ejector units X 26.7)L4 is L2 plus about 30.
L1L2
(L3)(L4)
2 3 4 5 6 7 8 9 10 11 12 13 14 15 1685
115137.5148
101131
162.5173
117147175
185.5
133163
187.5198
149179200
210.5
165195225
235.5
181211
237.5248
197227250
260.5
213243
262.5273
229259
287.5298
245275300
310.5
261291
312.5323
277307
337.5348
293323350
360.5
309339
362.5373
L n
VQ2000
L10=L3+50, L11=L4+50
Dustproof SI unit: L5=16+108, L6=L3+25, L7=L4+25
Equation L1=16+53, L2=16+83 n: Station (Max. 16)
Dust tight/jet proof SI unit: L8=16n+118.5, L9=16n+131
Dimensions (mm)
Note) Manifolds with SI unit for Matsushita's MEWNET FP and Allen Bradley Co.'s model are the same with L5, L6 and L7 dimensions of dust-proof SI unit.
The broken lines indicate DIN rail mounting style [–D].
ManifoldS kit………SV5Q21, #6
Valve2 position single …SV5Q21, #72 position double…SV5Q21, #83 position …………SV5Q21, #8
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
1.10-147
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-148
Manifold Options/For VQ1000
Blank plate assemblyVVQ1000-10A-1
It is mounted on a specific position of a manifold block from which a valve is removed for mainte-nance or in which a spare valve is planned to be mounted.
Individual SUP spacerVVQ1000-P-1-C6
When the same manifold is to be used for different pressures, individual SUP spacers are used as SUP ports for different pressures. (One station space isoccupied. )Block both sides of the station, for which the supply pressure from the individual SUP spacer is used, with SUP block plates. (See the application ex.)∗ Specify the spacer mounting position and SUP block plate position by means of the manifold specification form. The block plate are used in two places for one set. (Two SUP block plates for blocking SUP station are attached to the individual SUP spacer. )∗ Electric wiring is connected to the position of the mani- fold station where the individual SUP spacer is mounted.
Individual EXH spacerVVQ1000-R-1-C6
When valve exhaust affects other stations due to the circuit configuration, this spacer is used for individualvalve exhaust. (One station space is occupied. ) Block both sides of the individual valve EXH station. (See the application ex. ) ∗ Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the using manifold specification form. The block plate are used in two places for one set.∗ An EXH block base ass'y is used in the blocking posi- tion when ordering an EXH spacer incorporated with a manifold No. However, do not order an EXH block base ass'y because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base ass'y because it is not attached to the spacer.∗ Electric wiring is connected to the position of the mani- fold station where the individual EXH spacer is mounted.
SUP block plateVVQ1000-16A
When high and low pressures are simultaneously supp-lied to one manifold, a block plate is inserted between stations under different pressures.∗ Specify the number of stations by using a manifold specification form.
Blank plate with connector
<Blocking indication label>
VVQ1000–1C –
When using block plates for SUP passage, indication label for confirmation of the blocking position from out-side is attached. (one label of each)∗ When ordering a block plate incorporated with the manifold No., a block indication label is attached to the manifold.
Manifold
Connector
Lead wire length (mm)
1 VV5Q11
– Without connector
With connector/2 wire
With connector/4 wire
12
— 300600
10001500
61015
200025003000
202530
Connector assembly No.
SUP passage block
AXT661– A–Lead wire length
4 wire2 wire
4344
— 300mm600mm
1000mm2000mm3000mm
6102030
Blank plate with a connector for individually outputing electricity to drive a single valve or equipment that are not on the manifold base.∗ When “N” is suffixed to the nameplate, the plate will be different from a standard shape.Note) Electric current should be 1A or less. (Including the mounted valves. )
643
Val
veO
ptio
n
Name/Type Stations 1 2 3 4 5 6 7
Single
Individual EXH spacerVVQ1000-R-1-C6
EXH cut-off location: Specify 2 places.
Individual EXH spacer +
EXH block base ass'y
Valve+
EXH block base ass'y
Manifold options…………SV5Q11OP, #1 to #3
SUP/EXH passage block
VQ 1000/2000 Plug-in UnitBase Mounted
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Blank plug (For One-touch fittings)
KQP- -X19 X19
It is inserted into an unused cylinder port and SUP/EXH ports.The minimum order quantity is 10 pcs.
It is used for piping that extends upward or downward from the manifold.When installing it in part of the manifold stations,specify the ass'y no. and the mounting position and number of stations by means of the manifold specifica-tion form.
Name plate [-N]VVQ1000-N-Station (1 to Max. stations)
Elbow fitting assemblyVVQ1000-F-L(C3, C4, C6, M5)
It is a transparent resin plate for placing a label that indicates solenoid valve function, etc.Insert it into the groove on the side of the end plate and bend it as shown in the figure.
Port plug
The plug is used to block the cylinder port when usinga 4 port valve as a 3 port valve.
VVQ0000-58A
23040608 Color: White
3.2468
KQP-23-X19KQP-04-X19KQP-06-X19KQP-08-X19
161618
20.5
31.5323539
3.26810
A L DModelFittingssize ød
Dimensions (mm)
EXH block base assemblyVVQ1000-19A- -(C3, C4, C6, M5)
For F kit (2 to 12 stations)/Double wiring
For F kit (13 to 24 stations)/Double wiring
For F kit (2 to 24 stations)/Single wiring
For P, G, T, S kit (2 to 12 stations)/Double wiring
For P, G, T, S kit (13 to 24 stations)/Double wiring
For P, G, T, S kit (2 to 24 stations)/Single wiring
L0 kit
L1 kit ∗1 to 8 stations
L2 kit
F1F2F3P1P2P3L0∗
L1∗
L2∗
FPL
Manifold block ass'y Electrical entry
The manifold block ass'y is used between stations for which exhaust is desired to be divided when valve exhaust affects other stations due to the circuit configuration. The EXH passage on the D-side is blocked in the EXH block base ass'y. It is also used in combination with an indi-vidual EXH spacer for individual exhaust.
∗ When ordering by using the manifold specification form, specify the EXH block base ass'y no. by adding suffix “∗” be- low the manifold no.∗ Specify the number of stations by using the manifold specification form.
<Blocking indication label>When blocking the EXH passage with an EXH block base ass'y, indication label for confirmation of the block-ing position from outside is attached. (one label for each)
∗ When ordering a EXH block base incorporated with the manifold No., a block indication label is attached to the manifold.
EXH passage block SUP/EXH passage block
Check valve for prevention of back pressure assembly [–B]VVQ1000-18A
It prevents cylinder malfunction caused by other valve exhaust. Insert it into R (EXH) port on the manifold side of a valve which is affected. It is effective when a single action cylinder is used or an exhaust center type sole-noid valve is used.Note) When a check valves for back pressure preven- tion is desired to be installed only in desired manifold stations, write clearly the part No. and specify the number of stations by using a manifold specification form.
∗ When ordering assemblies incorporated with a manifold, add suffix “–B” to the manifold No. (When installed in all manifold
stations.)
∗ When ordering assemblies incorporated with a manifold, add suffix “-N” to the manifold No.
∗ When ordering a plug incorporated with a manifold, indicate “CM” for the port size in the manifold no., as well as, the mounting position and number of stations and cylinder portmounting positions, A and B, by means of the manifold specification form.
∗ Lightly screw an M3 screw in the port plug hole and pull it for removal.
∗ When ordering an assemblies incorporated with a manifo indicate “L” or “B” for the manifold port size. (When installed in all stations.)
(Precautions)The check valves for prevention of back
pressure ass'y is assembly parts with a
check valve structure. However, as slight
air leakage is allowed for the back pressure,
take care the exhaust air will not be throttled
at the exhaust port.
When a check valves for prevention of back
pressure is mounted, the effective area of
the valve will decrease, by about 20%.
1.
2.
Blank plug……SV5Q11OP, #6 to #9Elbow fitting ass’y……SV5Q11OP, #10
1.10-149
VQ 1000/2000 Plug-in UnitBase Mounted
Manifold Options/For VQ1000
DIN rail mounting bracketVVQ1000-57A
It is used for mounting a manifold on a DIN rail. The DIN rail mounting bracket is fixed to the manifold end plate. (The specification is the same as that forthe option “–D”. )
2 stations matching fitting assemblyVVQ1000-52A-C8
For driving a cylinder with a large bore, valves for two stations are operated to double the flow rate. This ass'y for the cylinder port is used in that case. The ass'y is equipped with one-touch fittings for a ø8 bore.
Regulator unitVVQ1000-AR-1The regulator controls the SUP air pressure in a manifold.
Silencer (EXH port)
This silencer is to be inserted into the EXH port (One–touch fittings) of the common exhaust.
Built-in silencer, Direct exhaust [-S]
This is an exhaust port on a top the manifold end plate. The built–in silencer exhibits an excellent noise suppression effect. (Silencing effect: 30dB)
SpecificationsMax. operating pressure
Setting pressure range
Ambient and fluid temperature
Fluid
Cracking pressure
Structure
0.8MPa
0.05 to 0.7MPa
5 to 50˚
Air
0.02MPa
Relieving style
∗ The bore for the manifold no. is “CM.” Clearly indicate the 2–station matching fittings ass'y no., and specify the number of stations and positions by means of the manifold specifications.
Note) A large quantity of drainage generated in the air source results in exhaust of air together with drainage.See p.1.10-158 for maintenance.
1 set of DIN rail mounting bracket is used for 1 set of manifold
(2 DIN rail mounting brackets).
How to OrderIndicate an option symbol “-G∗” for the manifold no. and be sure to specify the mounting position and number of stations by means of the manifold specification form. Oneunit is counted as one station and occupies a space forthree stations, therefore, pay attention to the manifold size.The regulator valve unit, to which no wire is connected, valves can be mounted up to the standard max. number of stations of each kit.
How to Order ManifoldVV5Q11–14C6FUO–DG2
Number of manifold stationsNumber of mounted valves (12)
+ Number of regulator units (2)
List option symbols in alphabetical order
With regulator unit
Number of regulator units (2) (Max. 3 units)
Pressure settingCheck the supply pressure and then turn the pressure control screw to set the secondary pressure. Turning thescrew clockwise will increase the secondary pressurewhile turning it counterclockwise decrease the pressure. (Set the pressure by turning the screw in the increase direction.)
InstallationSince some level of the actuator's operational frequency may lead to a sharp pressure change, pay attention to thepressure gauge durability.
VQ1000
Serise Model A L D
8 AN200-KM8 59.3 77.8 22 30
Eflective area (mm2)(Cv)
Silencingeffect dB
Fittingssize ød
Dimensions (mm)
20(1.1)
∗ When ordering assemblies incorporated with a manifold, add suffix “-D” to the manifold No.
∗ When ordering assemblies incorporated with a manifold, add suffix “S” to the manifold No.
Caution
1.10-150
VQ 1000/2000 Plug-in UnitBase Mounted
1.10-164
Base Mounted
How to Order Manifold
05 08 C4 F DU1VV5Q
Stations01 1 station
……
The max. number of sta-tions differs from kit to kit.(Refer to the table below)
Kit/Electrical entry/Cable length
05 VQ0000
Series
OptionNone
DIN rail mountingSpecial wiring specification (Not double wiring)
With name plateBuilt-in silencer (Direct exhaust)
Note 1) When specifying more than one option, please list alphabetically.Example)-DNSNote 2) F, P, S, and T kits for VQ0000 are all equipped with a DIN rail, so include suffix “-D.”Note 3) Specify the wiring specifications by means of the manifold specification form. (Except for C kit.)
–DKNS
OptionKit
(3)
Symbol
Port sizeOne-touch fitting for ø3.2One-touch fitting for ø4
M5 threadMixed size/with port plugNote 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Options” on p1.10-198 for One-touch fittings in inch sizes. Note 3) M5 fittings for M5 thread are attached without being incor- porated.
C3C4M5CM
Cylinder ports
(1)
(2)
Symbol
F Kit(D-sub connector) P Kit
(Flat cable connector)
T Kit(Terminal box) C Kit
(Connector) S Kit(Serial transmission unit)
Connector locationTop (vertical) Side (horizontal)
Connector locationTop (vertical) Side (horizontal)
U0U1U2U3
S0S1S2S3
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
Max. 16 stations
(2)
P.1.10-170U0U1U2U3
S0S1S2S3
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
Max. 16 stations
(2)
P.1.10-174
OABCDF1H
Without SI unitWith general type, Series EX300
SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)SI unit for 16-point Uni-wire System (NKE)
SI unit for 16-point Uni-wire H System (NKE)
Max.16stations
(2)(3)
The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24VDC. The dust-proof SI unit is also available. Contact SMC for details.
P.1.10-186
C Connector12
Applicable stations: 1 to 8Applicable stations: 5 to 16
Number of terminals:8, 1 row
Number of terminals:16, 2 rows Max. 16 stations
P.1.10-178T
Kit
Note 1) Besides the above, F and P kits with different number of pins are available. Refer to p.1.10-197 for details.Note 2) Refer to p.1.10-198 for details.Note 3) Consult SMC for the following transmission kits; Matsushita Electric Works Ltd., Allen-Bradley Co., Sunx, Fuji Electric Company Ltd., OMRON Corp.
P.1.10-182
F F P P
Kit KitKitKit
Kit
S
VQ0000
Plug Lead Unit
1.10-165
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
P.1.10-196Manifold Options
Refer to p.1.10-195 for cylinder port fittings.Refer to p1.10-213 for replacement parts.
Individual SUP spacer
VVQ0000-P-5-C4
Double check block
Individual EXH spacer
VVQ0000-R-5-C4
VVQ0000-N5-Station (1 to Max. stations)Silencer AN103-X233
VQ1000-FPG-
Manual override– Non-locking
push styleB Push-locking
slotted style
How to Order Valve
5 LOVQ 1 0 Y 5
1
2
3
4
With lead wire
L: L plugconnectorC Kit only
Except for AC.
G: Grommet
Without connector
MO: M plugconnector
With lead wire
M: M plugconnector
∗ ∗
∗ ∗Without connector
LO: L plugconnector
0
Electrical entry
Note 1) LO or MO type valve is used for F, P, T, and S kits.The plug coneector and
lead wire are attached to the manifold.Note 2) In cases of L and M type the connect-
or direction is based on the pilot valve. ∗ With indicator light and surge voltage supressor.
Note) The C kit is applicable to 200/220V AC. Contact SMC for other kits.
01
5 VQ0000
Note 1) Refer to “Options” on p.1.10-198 for negative COM specifications.Note 2) F, P, T and S kits requires connector ass'y when in- creasing valve stations. Refer to “Options” on p1.10-198 for parts nos.
Ordering example
The “∗” mark is an assembling mark. Prefix with “∗” to parts nos. of solenoid valves, etc.
Specify valve and option nos. below the manifold base no. When arrangement is complicated, specify the nos. by using amanifold specification form.
1 set (F kit 7 station manifold base No.)3 set (Single solenoid No.)2 set (Double solenoid No.)2 set (3 position solenoid No.)
VV5Q05-07C4FS2-D∗ VQ0150-5MO∗ VQ0250-5MO∗ VQ0350-5MO
How to Order Manifold Ass'y (Example)
Blank plugKQP- -X19
Name plate [-N∗]VVQ0000-57A-5DIN rail mounting bracket [-D]Blank plate assembly
VVQ0000-10A-5
SUP/EXH block plate VVQ0000-16A-5-
PR
PR
Built-in silencer, Direct exhaust [-S]
23040608
VQ00000
…………
Note 1) Refer to p1.10-168 for AC.
H
Y
DC AC
Configuration
Series
2 position single
2 position double
3 position closed center
3 position exhaust center
MetalRubber
Seal
Body
Specification
Standard
Highpressure
Lowwattage
Symbol
– (1.0W)
(1)
(1.5W)
(0.5W)
Pilot valve100V AC (50/60Hz)200V AC (50/60Hz)110V AC (50/60Hz)220V AC (50/60Hz)
24V DC12V DC
Coil voltage123456
1.10-166
VQ1000Base Mounted
Plug Lead UnitHow to Order Manifold
12 08 C6 F DU1VV5Q
Stations01 1 station
……
The max. number of sta-tions differs from kit to kit.(Refer to the table below)
Kit/Electrical entry/Cable length
12 VQ1000Series
Option
NoneCheck valve for prevention of back pressure
DIN rail mountingSpecial wiring specification (Not double wiring)
With name plateBuilt-in silencer (Direct exhaust)
Note 1) If specifying more than one option, please list alphabetically. Example) -BNSNote 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. If not all stations need this check valve, specify the stations where check valves are installed by mani- fold specification form. Note 3) Manifolds are all equipped with a DIN rail, so indicate suffix “D”.Note 4) Specify the wiring by means of the mani- fold specification form. (Except for C kit)
BDKNS
Option Kit
(4)
Symbol
–Port size One-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6
M5 threadMixed size/with port plug
Elbow One-touch fitting ø3.2 for top pipingElbow One-touch fitting ø4 for top pipingElbow One-touch fitting ø6 for top piping
Elbow M5 thread for top pipingElbow One-touch fitting ø3.2 for bottom pipingElbow One-touch fitting ø4 for bottom pipingElbow One-touch fitting ø6 for bottom pipingElbow M5 thread for bottom piping
Mixed size for elbow piping
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Options” on p.1.10-198 for One-touch fittings in inch sizes. Note 3) M5 fittings for M5 thread are attached without being incorporated.
C3C4C6M5CML3L4L6L5B3B4B6B5LM
Cylinder portsSymbol
F Kit(D-sub connector) P Kit
(Flat cable connector)
T Kit(Terminal block) C Kit
(Connector) S Kit(Serial transmission unit)
Connector locationTop (vertical) Side (horizontal)
U0U1U2U3
S0S1S2S3
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
Max. 16 stations
(2)
Max. 16 stations
(2)
P.1.10-170U0U1U2U3
S0S1S2S3
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
P.1.10-174
The valve is equipped with an indicator light and surge voltage su-ppressor, and the voltage is 24VDC. The dust-proof type SI unit is also available. Refer to p.1.10-186 for details.
P.1.10-186
C Connector12
Applicable stations: 1 to 4
Applicable stations: 5 to 8
Number of terminals: 8, 1row
Number of terminals: 16, 2rows Max. 16 stations
P.1.10-178T
Kit
Note 1) Besides the above, F and P kits with different number of pins are available. Refer to p.1.1-197 for details.Note 2) Refer to p.1.10-196 for details.
P.1.10-182
F F
Connector locationTop (vertical) Side (horizontal)
PP
Kit KitKitKit
(2)
SKit
OABCDEF1GHJ1J2KQR1R2V
Without SI unitWith general style, Series EX300
SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)
SI unit for MEWNET/F System (Matsushita Electric Works Ltd.)SI unit for 16 point Uni-wire System (NKE)
SI unit for Remote I/O (RIO) System (Allen-Bradley Co.)SI unit for 16 point Uni-wire H System (NKE.)SI unit for 16 point S-LINK System (Sunx)SI unit for 8 point S-LINK System (Sunx)
SI unit for T-LINK Mini System (Fuji Electric)SI unit for Device Net and Compo Bus/D (OMRON)
SI unit for 16 point Compo Bus/S (OMRON)SI unit for 8 point Compo Bus/S (OMRON)SI unit for CC-LINK (Mitsubishi Electric)
(2)
Max. 16 stations
Max. 16 stations
Max. 8
Max. 8 Max. 16
(3)
1.10-167
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
P.1.10-192Manifold Options
Refer to p.1.10-195 for cylinder port fittings.Refer to p.1.10-215 for replaceable parts.
Individual SUP spacerVVQ1000-P-1-C6
Double check block
Individual EXH spacerVVQ1000-R-1-C6 VVQ1000-N2-Station (1 to Max. stations)
Silencer AN200-KM8
VVQ1000-FPG-
Elbow fitting assemblyVVQ1000-F-L
Check valve for prevention of back pressure assembly [-B]VVQ1000-18A
Manual override– B Push-locking
slotted style
C Push-locking lever style
How to Order Valve
1 LOVQ 1 0 Y 5Series
1
1 VQ1000
2
3
4
5
Configuration2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
with lead wire
L: L plugconnector
With indicator light and voltage suppressor
With indicator light and voltage suppressor
without connector
LO: L plugconnector
1
Electrical entry
Note) LO type valve is used for F, P, T, and S kits. The plug connector and lead wire are attached to the manifold.
Coil voltage56
24V DC12V DC
Seal
Body
MetalRubber
01
1 VQ1000
Note 1) Refer to “Options” on p.1.10-198 for negative COM specifications.Note 2) F, P, T and S kits requires connector ass'y when increasing valve stations. Refer to “Options” on p.1.10-198 for parts nos.
Specify valve and option nos. below the manifold base no. When arrangement is complicated, specify the nos. by using a manifold specification form.
How to Order Valve Manifold Ass'y (Example)
Blank plugKQP- -X19
23040608
Name plate [-N∗]
Blank plate assemblyVVQ1000-10A-1
SUP/EXH block plateVVQ1000-16A-2
Built-in silencer,Direct exhaust [-S]
Port plug VVQ0000-58A
C3C4C6M5
2 stations matching fitting assemblyVVQ1000-52A-C8
The “∗” mark is an assembling mark.Prefix “∗” to parts nos. of solenoid valves, etc.
1 set (F kit 8 station manifold base No.)4 sets (Single solenoid No.)4 sets (Double solenoid No.)
………………
VV5Q12-08C6FU2-D∗VQ1110-5LO∗VQ1210-5LO
Note) Refer to p.1.10-168 for AC type.
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC
(1.0W)
(1.5W)
(0.5W)
Non-lockingpush style
Ordering example
1.10-168
Series Configuration Model
VQ0000
VQ1000
2 p
osi
tio
n3
po
siti
on
2 p
osi
tio
n3
po
siti
on
Single
Single
Double
Double
Closedcenter
Closedcenter
Exhaustcenter
Exhaustcenter
Pressurecenter
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
VQ0150
VQ0151
VQ0250
VQ0251
VQ0350
VQ0351
VQ0450
VQ0451
VQ1110
VQ1111
VQ1210
VQ1211
VQ1310
VQ1311
VQ1410
VQ1411
VQ1510
VQ1511
2.7 (0.15)
3.6 (0.2)
2.7 (0.15)
3.6 (0.2)
2.0 (0.11)
2.7 (0.15)
2.0 (0.11)
2.7 (0.15)
3.6 (0.2)
5.4 (0.3)
3.6 (0.2)
5.4 (0.3)
3.6 (0.2)
5.4 (0.3)
3.6 (0.2)
5.4 (0.3)
3.6 (0.2)
5.4 (0.3)
Response time (ms)
12 or less
15 or less
10 or less
15 or less
20 or less
25 or less
20 or less
25 or less
12 or less
15 or less
10 or less
15 or less
20 or less
25 or less
20 or less
25 or less
20 or less
25 or less
15 or less
20 or less
13 or less
20 or less
26 or less
33 or less
26 or less
33 or less
15 or less
20 or less
13 or less
20 or less
26 or less
33 or less
26 or less
33 or less
26 or less
33 or less
36
50
78
64
Weight (g)Low wattage
ACStandard: 1W
H: 1.5W
(2)(1)
(3)Effective area (mm2) (Cv)
Note 1) Cylinder port size C4: (VQ0000), C6: (VQ1000) without check valve option for prevention of back pressure.Note 2) As per JISB8375-1981(supply pressure; 0.5 MPa; with indicator light and surge voltage suppressor; clean air) The response time is subject to the pressure and quality of the air. The values at the time of ON are given for double styles.Note 3) AC type is only for VQ0000.
Standard Specifications
Model
Ambient and fluid temperature
Lubrication
Manual override
Impact/Vibration resistance
Protection structure
Coil rated voltage
Allowable voltage
Coil insulation
Single
Double
3 position
Min. operating
pressure
Seal
Fluid
Max.operating pressure
Metal seal
Air/lnert gas
0.1MPa
0.1MPa
0.1MPa
–10 to +50˚CNot required
Non-locking push style/Push-locking slotted or lever style (Option)
150/30m/s2
Dust proof
12, 24V DC, 100, 110, 200, 220V AC (50/60Hz)
±10% of rated voltage
Class B or equivalent
1W DC (42mA), 1.5W DC (63mA), 0.5W DC (21mA),
1W DC (83mA), 1.5W DC (125mA), 0.5W DC (42mA),
Inrush 0.5VA (5mA), Holding 0.5VA (5mA)
Inrush 0.55VA (5mA), Holding 0.55VA (5mA)
Inrush 1.0VA (5mA), Holding 1.0VA (5mA)
Inrush 1.1VA (5mA), Holding 1.1VA (5mA)
Rubber seal
Air/lnert gas
0.15MPa
0.1MPa
0.2MPa
Power
consumption
(Current value)
24V DC
12V DC
100V AC
110V AC
200V AC
220V AC
Valve
Solenold
(3) (4)
(3) (4)
(1)
(5)
(5)
(5)
(5)
(2)
Note 1) Use dry air to prevent dew condensation when operating at low temperature.Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the main valve and arm-ature, for both energized and de-energized states.
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2,000 Hz. Test was performed at both energize and de-energized states to the axis and right ang-
le directions of the main valve and armature. (Value in the initial stage.)Note 3) Value for high pressure type (1.5W)Note 4) Value for low pressure type (0.5W)Note 5) AC type is available only on VQ0000.
0.7MPa(High pressure type: 0.8MPa)
Base MountedVQ0000/1000Plug Lead Unit
1.10-169
Manifold Specifications
Series Base model Electrical connection Applicablestations
Applicablesolenoid
valve
Porting specifications
Port sizePortlocation P, R A, B
(1)(2) 5 station
weight(g)
VQ0000
VQ1000
Side
Side
330(Single)
400(Double, 3-
position)
818(Single)
885(Double, 3-
position)
F kit: D-sub connectorP kit: Flat cable connectorT kit: Terminal blockC kit: Individual connectorS kit: Serial transmission unit
F kit: D-sub connectorP kit: Flat cable connectorT kit: Terminal blockC kit: Individual connectorS kit: Serial transmission unit
VV5Q05- VQ050VQ051
VQ110VQ111VV5Q12-
C3 (ø3.2)
C4 (ø4)
M5(M5 thread)
C3 (ø3.2)
C4 (ø4)
C6 (ø6)
M5 (M5 therad)
1 to 16 stations
1 to 16 stations
C6 (ø6)
Option:built-insilencer
(Direct exhaust)
Option:built-insilencer
(Direct exhaust)
C8 (ø8)
Note 1) One-touch fittings in inch sizes are also available. Refer to p.1.10-198 for details.Note 2) Refer to p1.10-198 for details.
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-170
VQ0000/1000Kit(D-sub Connector)F
The D-sub connector reduces installation labor for electrical connection.The D-sub connector (25 pin std., 15 pin option)conforms with MIL permitting use of commercial connectors with wide interchangeability.Top or side connector receptacle position can be selected in accordace with the available mounting space.Max.16 stations.
D-sub connector (25 pin)
AXT100-DS25-
The D-sub connector cable ass'y can ordered individually or included in a specific manifold model No.Refer to “How to Order Manifold”.
Wire color table by terminal number of D-sub connector cable ass'y:
Note) Types with 15 pin are also available. See p.1.10-197 for details.
Terminal No. Wire color Dot marking12345678910111213141516171819202122232425
BlackBrownRed
OrangeYellowPinkBlueVioletGrayWhiteWhiteYellow
OrangeYellowPinkBlueVioletGray
OrangeRed
BrownPinkGrayBlackWhite
–––––––
WhiteBlackBlackRed RedRed
BlackBlackWhite
––
BlackWhiteWhiteRedRed
White–
How to Order Manifold
D1U12 08 C6VV5Q F
0512
VQ0000VQ1000
Series/Manifold
Stations
Connector location
Cylinder ports
01 1 station
08 8 stations
……
Cable (length)0123
Without cableWith cable (1.5m)With cable (3m)With cable (5m)
Note 1) As option, the maximum num- ber of stations can be increased by special wiring spe- cifications. Refer to p.1.10-198 for details.
(1)
US
Top (vertical)Side (horizontal)
OptionCheck valve for
prevention of back perss.DIN rail mounting
Option
Note 1) If specifying more than one option, please list alphabetically. Example) -BNSNote 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. If not all stations need this check valve, specify the stations where check valves are installed by using a manifold specification form. Note 3) F kit of VQ0000 and all of VQ1000 are equipped with a DIN rail, so in- dicate suffix “D”.Note 4) Specify the wiring by means of the manifold specification form.
B
D
N
S
Series
VQ0000VQ1000
Porting specifications
Portlocation
SideSide
Port size
P, RC6C8
A, BC3, C4, M5
C3, C4, C6, M5
Applicablestations
Max.16Max.16
Manifold Specifications
Plug lead unit
K
Symbol
Special wiring specification (Not double wiring)
With name plateBuilt-in silencer(Direct exhaust)
VQ0000 VQ1000(2)
(3)
(4)
C3C4C6M5CM
Symbol VQ0000 VQ1000Port sizeOne-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6
M5 threadMixed size/with port plug
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Options” on p.1.10-198 for One-touch fittings in inch sizes.
ltem CharacteristicConductorresistance
Ω/km, 20˚C
65or less
Insulationresistance
MΩ/km, 20˚C
Voltage limit V,1min, AC
1000
5or more
Note) The min. bending radius of D-sub cable assembly is 20mm.
Electric characteristics
Cablelength (L)
Ass'y No
1.5m
3m
5m
AXT100-DS25-015
AXT100-DS25-030
AXT100-DS25-050
Note
Cable 25 core X 24AWG
∗ For other commercial connectors, use a 25-pin female connector made in conformity with MIL-C-24308.
D-sub connector cable assembly (Option)
Cable Assembly
015030050
1644
L
8
14 25
1 13
47.04
55 2-M2.6 X 0.45
Socket side
Terminal No.
≅ø10
Multicore vinyl cable0.3mm2 X 25C
1.10-171
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Electrical Wiring Specifications
Irrespective of the valves or options, the internal wiring is madedouble(connected to SOL. A and SOL. B)for respective stations of the manifold. The optional specification permits mixture of single and double wiring.See p.1.10-198 for details.
How to Order Valve
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BCOM.
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
13
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( – )
Black
Yellow
Brown
Pink
Red
Blue
Orange
Purple
Yellow
Gray
Pink
Orange
Blue
Red
Purple
Brown
Orange
–
Black
–
Black
–
White
–
–
–
–
–
Black
–
White
White
White
Red
Terminal No. Polarity Lead wire color
D-sub cable ass'y015
(AXT100-DS25-030)050
wire color tableDot marking
Positive COM
Negative COM
Note 1) Use negative COM valves for negative COM specification manifolds. (See p.1.10-198)
(1)
VQ0000
VQ1000
Metal
Rubber
Plug lead unit
51
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center (VQ1000 only)
12345
01
Series
01
Seal
Configuration
Non-locking push style
Push-locking slotted style
Push-locking lever style (1)
–BC
Manual override
100V AC(50/60Hz)
110V AC(50/60Hz)
24V DC
12V DC
1
3
56
Coil voltageBody
VQ 1 1 1 0 Y 5 LO
VQ0000
VQ1000
L plug connector without connector
M plug connector without connector
VQ0000 VQ1000
LOMO
Electrical entry
The total number of stations is tabulated starting from stationone on the D side.
…………………………………………………………………
1 set–Manifold base No.4 sets–Valve No. (Stations 1 to 4)4 sets–Valve No. (Stations 5 to 8)2 sets–Valve No. (Stations 7 to 8)1 set–Blank plate No.(Station 9)
How to Order Manifold Ass'y
Specify valve and option Nos. below the manifold base no.
(Example)
Write sequentially from the 1st station on the D side.When part nos. written col-lectively are complicated,specify by using a manifoldspecification form.
Add prefix “∗” to parts nos.of the solenoid valves, etc.
D-sub connector kit with 3m cableVV5Q12-08C6FU2-D ∗ VQ1110-5LO ∗ VQ1210-5LO ∗ VQ1310-5LO ∗ VVQ1000-10A-1
Note) Plug connector and lead wire are attached to the manifold.
Note 1) VQ1000 only.
Note 1) Refer to “Options” on p.1.10-198 for negative COM specifications.Note 2) F kit requires connector ass'y when increasing valve stations. Refer to “Options” on p.1.10-198 for part No.
VQ0000 VQ1000
Note 1) Refer to p.1.10-168 for AC.
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC AC
(1.0W)
(1.5W)
(1)
1 station
2stations
3stations
4stations
5stations
6stations
7stations
8stations
(0.5W)
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-172
L1L2L3L4
146.555.7
112.5123
257.466.4125
135.5
368.177.1
137.5148
478.887.8150
160.5
589.598.5
162.5173
6100.2109.2175
185.5
7110.9119.9175
185.5
8121.6130.6187.5198
9132.3141.3200
210.5
12164.4173.4237.5248
13175.1184.1250
260.5
14185.8194.8
250260.5
15196.5205.5262.5273
16207.2216.2275
285.5
10143152
212.5223
11153.7162.7225
235.5
Dimensions/Top entry connector[-FU](mm)
VQ0000/1000Kit (D-sub Connector)F
Dimensions/Side entry connector[-FS](mm)L n
L n
1137.5148
2150
160.5
3150
160.5
4162.5173
5175
185.5
6187.5198
7200
210.5
8212.5223
9225
235.5
12250
260.5
13262.5273
14275
285.5
15287.5298
16300
310.5
10225
235.5
11237.5248
VQ0000
Equation L1=10.7n+36, L2=10.7n+45 n: Station (Max. 16)
Side entry connection[–FS]
L3L4
Manifold F kit (Top entry connector)
…………SV5Q05M, #1 F kit (Side entry connector)
…………SV5Q05M, #2Valve 2 position single …SV5Q12V, #7 2 position double…SV5Q12V, #8 3 position …………SV5Q12V, #8
< >: AC
1.10-173
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
L1L2L3
Dimensions/Top entry connector [-FU] (mm)
L2L3
Dimensions/Side entry connector [-FS] (mm)L n
L n 182.5137.5148
293
150160.5
3103.5162.5173
4114175
185.5
5124.5187.5198
6135200
210.5
7145.5200
210.5
8156
212.5223
9166.5225
235.5
12198
262.5273
13208.5262.5273
14219275
285.5
15229.5287.5298
16240300
310.5
10177
237.5248
11187.5250
260.5
1162.5173
2175185.5
3187.5198
4187.5198
5200
210.5
6212.5223
7225235.5
8237.5248
9250
260.5
12275
285.5
13287.5298
14300
310.5
15312.5
323
16312.5323
10250
260.5
11262.5273
VQ1000
Equation L1=10.5n+72 n: Station (Standrad max. 16)
Side entry connection [-FS]
Manifold F kit (Top entry connector) …SV5Q12M, #1 F kit (Side entry connector)…SV5Q12M, #2Valve 2 position single …SV5Q12V, #7 2 position double…SV5Q12V, #8 3 position …………SV5Q12V, #8
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-174
Series
VQ0000
VQ1000
Applicablestations
Max.8
Max.8
Port sizePortlocation
Side
Side
Porting specifications
A, B
C3, C4, M5
C3, C4, C6, M5
P, R
C6
C8
MIL flat cable connector reduces installation labor for electrical connection.The connector (26 pin; 10, 16, and 20 pin option) conforms with MIL spec. permitting use of widely interchangeable comme- rcial connectors.Top or side receptacle position can be selected in accordance with the available mounting space.Max.16 stations.
Flat cable (26 pin)
Manifold Specifications
AXT100–FC26–1 to 3Flat cable connector ass'y can be ordered individually or included in a specific manifold model no. Refer to “How to Order Manifold”.
Flat cable connector assembly (Option)NoteAss'y No.
AXT100-FC26-1AXT100-FC26-2AXT100-FC26-3
Cable length (L)
1.5m3m5m
Cable 26 coreX 28AWG
∗ For other commercial connectors, use a 26 pin type with strain relief made in conformity with MIL-C-83503.
Note) Types with 10, 16, or 20 pin are also available. See p.1.10-197 for details.
How to Order Manifold
1 station
16 stations (1)
01
16
Plug leadunit
Port size VQ0000 VQ1000
VQ0000 VQ1000
SymbolOne-touch fittings for ø3.2
One-touch fittings for ø4
One-touch fittings for ø6
M5 thread
Mixed size/with port plug
C3C4C6M5CM
Top (vertical)
Side (horizontal)US
OptionSymbol Option
B
D
N
S
K
Check valve forprevention of back press.
DIN rail mounting
Special wiring specification(Not double wiring)
With name plate
Built-in silencer(direct exhaust)
Connector location
Cylinder ports
VQ0000
VQ1000
0512
Series/Manifold
Stations
Cable Assembly
VV5Q 08 C612 U 1 DP
Note 1) As option, the maximum number of stations can be increased by special wiring specifications. Refer to p.1.10-198 for details.
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Options” on p.1.10-198 for One- touch fittings in inch sizes.
VQ0000/1000Kit (Flat Cable Connector)P
Without cable
With cable(1.5m)
With cable(3m)
With cable(5m)
0123
Cable(length)
Note 1) If specifying more than one option, please list alphabetically. Example) -BNSNote 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. If not all stations need this check valve, specify the stations where check valves are installed by using a manifold specification form. Note 3) P kit of VQ0000 and all of VQ1000 are equipp- ed with a DIN rail, so indicate suffix “D”.Note 4) Specify the wiring by means of the manifold specification form.
The total number of stations is tabulated
starting from one on the D side.
… …
(2)
(3)
(4)
1.10-175
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Electrical Wiring Specifications
Irrespective of the valves or options, the internal wiring is made double(connected to SOL.A and SOL.B)for respective stations of the manifold.The optional specification permits mixture of single and double wiring.See p.1.10-198 for details.
How to Order Valve
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BCOM.COM.
VQ0000
VQ1000
Metal
Rubber
Plug leadunit
51
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center (VQ1000 only)
12345
01
Series
01
Seal
Configuration
Non-locking push style
Push-locking slotted style
Push-locking lever style (1)
–BC
Manual override
Body
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
25
26
Terminal No.
Electrical wiring specifications
Polarity
1 station
PositiveCOM
NegativeCOM
Note 1) Use negative COM valves for negative COM specification manifolds. (See p1.10-198 )
Note) Plug connector and lead wire are attached to the manifold.
Note 1) Refer to “Options” on p.1.10-198 for negative COM specifications.Note 2) P kit requires connector ass'y when increasing valve stations. Refer to “Options” on p.1.10-198 for parts No.
VQ 1 1 1 0 Y 5 LO
VQ0000
VQ1000
(1)
L plug connector without connector
M plug connector without connector
VQ0000 VQ1000
LOMO
Electrical entry
Note 1) VQ1000 only.
Flat cable connector
1 set–Manifold base No.4 sets–Valve No. (Stations 1 to 4)4 sets–Valve No. (Stations 5 to 8)
How to Order Manifold Ass'y
Specify valve and option nos. below the manifold base no.
(Example)Flat cable kit with 3m cable
Write sequentially from the 1st station on the D side.When part Nos. written collecti- vely are compli- cated, specify by using a manifold specification form.
Add prefix “∗” to parts nos. of the solenoid valves, etc.
VV5Q12-08C6PU1-D …∗ VQ1110-5LO……..…∗ VQ1210-5LO……..…
100V AC(50/60Hz)
110V AC(50/60Hz)
24V DC
12V DC
1
3
56
Coil voltage VQ0000 VQ1000
Note 1) Refer to p.1.10-168 for AC.
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC AC
(1.0W)
(1.5W)
(0.5W)
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( + )
( – )
( – )
2 stations
3 stations
4 stations
5 stations
6 stations
7 stations
8 stations
(1)
–
–
–
–
–
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-176
L1L2L3L4
146.755.7
112.5123
257.466.4125
135.5
368.177.1125
135.5
478.887.8
137.5148
589.598.5150
160.5
6100.2109.2162.5173
7110.9119.9175
185.5
8121.6130.6187.5198
9132.3141.3200
210.5
12164.4173.4225
235.5
13175.1184.1237.5248
14185.8194.8250
260.5
15196.5205.5262.5273
16207.2216.2275
285.5
10143152200
210.5
11153.7162.7212.5223
Dimensions/Top entry connector [-PU] (mm)
VQ0000/1000 Kit(Flat Cable Connector)P
L3L4
Dimensions/Side entry connector [-PS] (mm)L n
L n
1137.5148
2150
160.5
3150
160.5
4162.5173
5175
185.5
6187.5198
7200
210.5
8212.5223
9225
235.5
12250
260.5
13262.5273
14275285.5
15287.5298
16300
310.5
10225
235.5
11237.5248
VQ0000
Equation L1=10.7n+36, L2=10.7n+45 n: Station (Max. 16)
Side entry connection [-PS]
ManifoldP kit (Top entry connector)
…………SV5Q05M, #3P kit (Side entry connector)
…………SV5Q05M, #4Valve
2 position single ……SV5Q05V, #72 position double……SV5Q05V, #83 position……………SV5Q05V, #9
< >: AC
1.10-177
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
L1L2L3
Dimensions/Top entry connector [-PU] (mm)
L2L3
Dimensions/Side entry connector [-PS] (mm)L n
L n 182.5137.5148
293150
160.5
3103.5150160.5
4114
162.5173
5124.5175
185.5
6135
187.5198
7145.5200
210.5
8156
212.5223
9166.5225
235.5
12198250
260.5
13208.5262.5273
14219275
285.5
15229.5287.5298
16240
287.5298
10177225
235.5
11187.5237.5248
1162.5173
2175185.5
3187.5198
4187.5198
5200
210.5
6212.5223
7225
235.5
8237.5248
9250
260.5
12275
285.5
13287.5298
14300
310.5
15312.5323
16312.5
323
10250
260.5
11262.5273
VQ1000
Equation L1=10.5n+72 n: Station (Max. 16)
Side entry connection [-PS]
ManifoldP kit (Top entry connector)……SV5Q12M, #3P kit (Side entry connector)……SV5Q12M, #4
Valve2 position single ……SV5Q12V, #72 position double……SV5Q12V, #83 position ……………SV5Q12V, #8
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-178
Series
VQ0000
VQ1000
Port
location
Side
Side
It is a standard terminal block style.Two quantities of teminals can be selected in accordance with the
number of stations. (8 terminals/16 terminals)Standard max. 8 stations. (Optional 16 stations possible.)
Electrical Wiring Specifications
Manifold Specifications
How to Order Manifold
1 station
16 stations (1)
01
16
Plug leadunit
VQ0000 VQ1000
OptionSymbol Option
B
D
K
N
S
Check valve for prevention of back press.
DIN rail mounting
Special wiring spec. (Not double wiring)
With name plate
Built-in silencer (Direct exhaust)
Cylinder ports
VQ0000
VQ1000
0512
Manifold
1 to 4 stations
5 to 8 stations
Terminal blocks
1 row
2 rows
Series/Manifold
Stations
VV5Q 08 C612 2 DT
VQ0000/1000Kit (Terminal Block)T
8 terminals in 1 row
16 terminals in 2 rows
1 to 4 stations (Double wiring), 8 stations (Single wiring) applicable
5 to 8 stations (Double wiring), 16 stations (Single wiring) applicable
12
Number of terminals
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.B
COM.
1
2
3
4
5
6
7
8
COM
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( + )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( – )
( + )
Terminal No. Terminal No.
1 stationSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.B
COM.
1
2
3
4
5
6
7
8
COM
In case of double wiring (standard apec.) T1 (Terminal block of 1 row): 1-4 stations T2 (Terminal block of 2 rows): 5-8 stationsT1 and T2 can be optionally chosen by adopting the combinations of single and double wiring(option spec.)etc.
The quantity of terminal blocks used depends on the number of manifold stations:
Irrespective of the valves or op-tions, the internal wiring is made double(connected to SOL.A and SOL.B)for respective stations of the manifold.The optional specification permitsmixture of single and double wiring.See p.1.10-198 for details.Note) Wiring other than those above
is possible. See p.1.10-198 for details.
Note) The number of terminal blocks can be chosen regardless of station qty. Suffix the option symbol, “ K,” when the wiring specification is special.
Open the terminal block cover to connect the wires to the terminal block. (With M3 thread)
Note1) Refer to p.1.10-198 for details.
Port sizeSymbolOne-touch fitting for ø3.2
One-touch fitting for ø4
One-touch fitting for ø6
M5 thread
Mixed size/with port plug (1)
C3C4C6M5CM
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Options” on p.1.10-198 for One-touch fittings in inch sizes.
Note 1) If specifying more than one option, please list alphabeti- cally. Example) -BNSNote 2) Models with a suffix “-B” have check valves for prevention
of back pressure at all manifold stations. If not all stationsneed this check valve, specify the stations where check
valves are installed by using a manifold specification form. Note 3) T kit of VQ0000 and all of VQ1000 are equipped with a DIN rail, so indicate suffix “D”.Note 4) Specify the wiring by means of the manifold specification form.
Applicablestations
Max. 8Max. 8
Port size
Porting specifications
A, B
C3, C4, M5
C3, C4, C6, M5
P, R
C6
C8
2 stations
3 stations
4 stations
5 station
6 stations
7 stations
8 stations
… …
(2)
(3)
(4)
1.10-179
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
How to Order Valve
VQ0000
VQ1000
Metal
Rubber
Plug leadunit
51
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center (VQ1000 only)
12345
01
Series
01
Seal
Configuration
Non-locking push style
Push-locking slotted style
Push-locking lever style (1)
–BC
Manual override
Body
VQ 1 1 1 0 Y 5
VQ0000
VQ1000
L plug connector without connector
M plug connector without connector
VQ0000 VQ1000
LOMO
Electrical entry
Note 1) VQ1000 only.
Note) Plug connector and lead wire are attached to the manifold.
Note 1) Refer to “Options” on p.1.10-198 for negative COM specifications.Note 2) T kit requires connector ass'y when increasing valve stations. Refer to “options” on p.1.10-198 for parts No.
1 set–Manifold base No.4 sets–Valve No. (Stations 1 to 4)3 sets–Valve No. (Stations 5 to 8)
How to Order Manifold Ass'y
Specify valve and option nos. below the manifold base no.
(Example)
Write sequentially from the1st station on the D side.When part nos. written coll- ectively are complica- ted, specify by using a manifold specification form.
Add prefix “ ∗ ” to parts nos. of the solenoid valves,etc.
Flat cable kit with 3m cableVV5Q12-07C6T2-D∗ VQ1110-5LO∗ VQ1210-5LO
100V AC(50/60Hz)
110V AC(50/60Hz)
24V DC
12V DC
1
3
56
Coil voltage
Note 1) Refer to p.1.10-168 for AC.
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC AC
(1.0W)
(1.5W)
(0.5W)
–
–
–
·····················
–
–
VQ0000 VQ1000
(1)
1.10-179
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
How to Order Valve
VQ0000
VQ1000
Metal
Rubber
Plug leadunit
51
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center (VQ1000 only)
12345
01
Series
01
Seal
Configuration
Non-locking push style
Push-locking slotted style
Push-locking lever style (1)
–BC
Manual override
Body
VQ 1 1 1 0 Y 5
VQ0000
VQ1000
L plug connector without connector
M plug connector without connector
VQ0000 VQ1000
LOMO
Electrical entry
Note 1) VQ1000 only.
Note) Plug connector and lead wire are attached to the manifold.
Note 1) Refer to “Options” on p.1.10-198 for negative COM specifications.Note 2) T kit requires connector ass'y when increasing valve stations. Refer to “options” on p.1.10-198 for parts No.
1 set–Manifold base No.4 sets–Valve No. (Stations 1 to 4)3 sets–Valve No. (Stations 5 to 8)
How to Order Manifold Ass'y
Specify valve and option nos. below the manifold base no.
(Example)
Write sequentially from the1st station on the D side.When part nos. written coll- ectively are complica- ted, specify by using a manifold specification form.
Add prefix “ ∗ ” to parts nos. of the solenoid valves,etc.
Flat cable kit with 3m cableVV5Q12-07C6T2-D∗ VQ1110-5LO∗ VQ1210-5LO
100V AC(50/60Hz)
110V AC(50/60Hz)
24V DC
12V DC
1
3
56
Coil voltage
Note 1) Refer to p.1.10-168 for AC.
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
H
Y
DC AC
(1.0W)
(1.5W)
(0.5W)
–
–
–
·····················
–
–
VQ0000 VQ1000
(1)
1.10-180
L1L2L3L4
146.755.7125
135.5
257.466.4
137.5148
368.177.1150
160.5
478.887.8150
160.5
589.598.5162.5173
6100.2109.2175
185.5
7110.9119.9187.5198
8121.6130.6200
210.5
9132.3141.3212.5223
12164.4173.4237.5
248
13175.1184.1250
260.5
14185.8194.8262.5273
15196.5205.5275
285.5
16207.2216.2287.5298
10143152225
235.5
11153.7162.7225
235.5
VQ0000/1000Kit (Terminal Block)T
L n
VQ0000
Dimensions (mm) Equation L1=10.7n+36, L2=10.7n+45 n: Station (Max.16)
This DWG shows the case of VV5Q05–T2–D
< >: AC
1.10-181
L1L2L3
182.5150
160.5
293
162.5173
3103.5175
185.5
4114187.5198
5124.5187.5198
6135200
210.5
7145.5212.5223
8156225235.5
9166.5237.5
248
12198
262.5273
13208.5275
285.5
14219
287.5298
15229.5300
310.5
16240
312.5323
10177250
260.5
11187.5250
260.5
Dimensions (mm)L n
VQ1000
Equation L1=10.5n+72 n: Station (Max.16)
This DWG shows the case of VV5Q12–T2–D
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-182
Series
VQ0000
VQ1000
Applicablestations
Max. 16Max. 16
Port sizePort
location
Side
Side
Porting specifications
A, B
C3, C4, M5
C3, C4, C6, M5
P, R
C6
C8
Standard with lead wires plug-connected to each valve individually.Max. 16 stations.
Wiring Specifications/Positive COM
Connector assembly (DC)
Manifold Specifications
How to Order Manifold
1 station
16 stations
01
16
Plug leadunit One-touch fitting for ø3.2
One-touch fitting for ø4
One-touch fitting for ø6
M5 thread
Mixed size/with port plug
VQ1000VQ0000
C3C4C6M5CM
Port sizeSymbol
Option
Cylinder portsVQ0000
VQ1000
0512
Socket(3 pcs.)300mm600mm
1000mm2000mm3000mm
Lead wire length
AXT661-14AAXT661-14A-6AXT661-14A-10AXT661-14A-20AXT661-14A-30
AXT661-13AAXT661-13A-6AXT661-13A-10AXT661-13A-20AXT661-13A-30
No. for single &VQ0000 double
No. for VQ1000 double
Series/Manifold
Stations
VV5Q 08 C612 NC
VQ0000/1000Kit (Connector)C
Note)
(3)
(2)
SOL.A
COM(+)
(Blue)
(Blue)
Black
Red
[Red]
[Red]
Lead wire color24VDC 100, 110 200, 220
SOL.A
SOL.B
(–)
COM(+)
(–)
The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Single solenoidVQ0000 double VQ1000 double solenoid
Note) The length of the lead wire provided is 300mm. When a valve with lead wire of 600mm or more is needed, specify both the valve without connector and the longer connector ass'y no.
Plug connector lead wire length
Example) Lead wire length 1000mm VQ1110-5LO …………3 pcs. AXT661-14A-10………3 pcs.
Note) 100/110V AC for single: AXT661-31A-∗; for double: AXT661-32A-∗ 200/220V AC for single: AXT661-34A-∗; for double: AXT661-35A-∗
Note: ( ) is for 100, 110VAC. [ ] is for 200, 220VAC
AXT661-12A
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form. Note 2) Refer to “Option” on p.1.10-198 for One- touch fittings in inch sizes.
VQ0000 VQ1000Symbol Option
–
B
D
N
S
Note
Check valve forprevention of back press.
DIN rail mounting
With nameplate
Built-in silencer (Direct exhaust)
Note 1) If specifying more than one option, please list alphabetically. Example) –BNSNote 2) Models with a suffix “–B” have check valves for prevention of back pressure at all mani- fold stations. If not all stations need this check valve, specify the stations where check valves are installed by using a manifold specification form. Note 3) VQ1000 are all equipped with a DIN rail, so indicate suffix “D”.
(–)VAC VAC
Lead wire color24VDC 100, 110 200, 220
V AC V ACBlack (Yellow) [Yellow]
Red (Blue) [Red]
White (Gray) [Gray]
… …
1.10-183
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Wiring Specifications/Negative COM (Option)
How to Order Valve
VQ0000
VQ1000
Metal
Rubber
Plug leadunit
51
2 position single
2 position double
3 position closed center
3 position exhaust center3 position pressure center (VQ1000 only)
12345
01
Series
01
Seal
Configuration
Non-locking push style
Push-locking slotted style
Push-locking lever style (1)
–BC
Manual override
Body
VQ 1 1 1 0 Y 5 L
VQ0000
VQ1000
Grommet (Except for AC)
L plug connector with lead wire
L plug connector without connector
M plug connector with lead wire
M connector without connector
VQ0000 VQ1000
GLLOMMO
Electrical entry
Note) Use negative COM valves for negative COM specification manifolds.
Note 1) Available only for VQ1000.
SOL.A (+)
COM(–)
Red
Black
Lead wire color Red
Black
White
Lead wire color SOL.A
SOL.B
(+)
COM(–)
(+)
The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Single solenoidDouble solenoid
Connector assembly
Socket (3 pcs.)300mm600mm
1000mm2000mm3000mm
Lead wire length
AXT661-14ANAXT661-14AN-6AXT661-14AN-10AXT661-14AN-20AXT661-14AN-30
AXT661-13ANAXT661-13AN-6AXT661-13AN-10AXT661-13AN-20AXT661-13AN-30
No. for single & VQ0000double No. for VQ1000 double
Note) The length of the lead wire provided is 300mm. When a valve with lead wire of 600mm or more is needed, specify both
the valve without connector and the longer connector ass'y no.
Plug connecter lead wire length
Example) Lead wire length 1000mm VQ1110N-5LO ………… 3 pcs. AXT661-14AN-10……… 3 pcs.
AXT661-12A
Note) Refer to “Options” on p.1.10-198 for negative COM specifications.
How to Order Manifold Ass'y
Specify valve and option nos. below the manifold base no.
(Example)
Write sequentially from the 1st station on the D side. When part nos. written collectively are complicated, specify by using a manifold spec- ification form.
Add prefix “∗” to parts nos. of the solenoid valves, etc.
Connector kitVV5Q12–08C6C-D··1 set –Manifold base No.∗ VQ1110-5············· 4 sets–Valve No. (Stations 1 to 3)∗ VQ1210-5············· 4 sets–Valve No. (Stations 4 to 7)∗ VVQ1000-10A-1···1 set –Blank plate No. (Stations 8)
Coil voltage VQ0000 VQ1000
Note 1) Refer to p.1.10-168 for AC .
Pilot valve 100V AC (50/60Hz)
200V AC (50/60Hz)(VQ0000 only)
110V AC (50/60Hz)
220V AC (50/60Hz)(VQ0000 only)
24V DC
12V DC
1
2
3
4
56
Specification
Standard
Highpressure
Lowwattage
Symbol
–
H
Y
DC AC
(1.0W)
(1.5W)
(0.5W)
(1)
–
–
–
–
–
–
––
–
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-184
L1L2
(L3)(L4)
146.755.787.598
257.466.487.5
98
368.177.1100110.5
478.887.8112.5123
589.598.5125
135.5
6100.2109.2137.5148
7110.9119.9150
160.5
8121.6130.6162.5173
9132.3141.3162.5173
12164.4173.4200
210.5
13175.1184.1212.5223
14185.8194.8225
235.5
15196.5205.5225
235.5
16207.2216.2237.5248
10143152175
185.5
11153.7162.7187.5198
Dimensions (mm)
VQ0000/1000Kit (Connector)C
VQ0000 The broken line indicate DIN railmounting style [–D].
L nEquation L1=10.7n+36, L2=10.7n+45 n: Station (Max. 16)
Manifold C kit ………………………… SV5Q05M, #5Valve 2 position single ……………SV5Q05V, #7 2 position double……………SV5Q05V, #8 3 position closed center……SV5Q05V, #9 3 position exhaust center …SV5Q05V, #9
< >: AC
1.10-185
L1L2L3
182.5112.5123
293
112.5123
3103.5125
135.5
4114137.5148
5124.5150
160.5
6135
162.5173
7145.5175
185.5
8156
187.5198
9166.5187.5198
12198225
235.5
13208.5237.5248
14219250
260.5
15229.5250
260.5
16240
262.5273
10177200
210.5
11187.5212.5223
Dimensions (mm)nL
VQ1000
Equation L1=10.5n+72 n: Station (MAX.16)
ManifoldC kit …………………… SV5Q12V, #5
Valve2 position single ………SV5Q12V, #72 position double………SV5Q12V, #83 position ………………SV5Q12V, #8
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-186
Series
VQ0000
VQ1000
Applicablestations
Max.16
Max.16
Port sizePortlocation
Side
Side
Porting specifications
A, B
C3, C4, M5
C3, C4, C6, M5
P, R
C6
C8
The serial transmission system minimizes wire mass and wire connection labor and promotes space savings. The system comes in SA (general type for small scale system) for
equipment with a small number of I/O points, or 32 points max., SB (applicable to Mitsubishi Electric models) for controlling 512 I/O points max.,SC (applicable to OMRON models), SD (applicable to Sharp
models: 504 points max.), SF (applicable to NKE models: 128 points max.), SJ (applicable to Sunx models), SK (applicable to Fuji Electric models), SQ (applicable to OMRON’s Compo Bus/D), and SR
(applicable to OMRON’s Compo Bus/S). Max. 8 stations. (Specify a option model with 9 to 16 stations by using a manifold specification form.)
Manifold Specifications
How to Order Manifold
1 station
16 stations (1)
01
16
Plug leadunit
port size VQ0000 VQ1000Symbol
One-touch fittings for ø3.2
One-touch fittings for ø4
One-touch fittings for ø6
M5 thread
Mixed size/with port plug
C3C4C6M5CM
Style
Cylinder ports
VQ0000
VQ1000
0512
Series/Manifold
Stations
VV5Q 08 C612 D XPAS
VQ0000/1000Kit(Serial Transmission Unit)S
VQ0000 VQ1000
Option
Dust proof styel (-XP)(VQ1000 only)
Symbol
B
D
N
S
Option
Check for prevention
of back press.
DIN rail mounting
Special wiring specification
(Not double wiring)
With name plate
Built silencer
(Direct exhaust)
K
(2)
(3)
(4)
Stations are sequentially numbered from the D side.Irrespective of the valves or options, the internal wiring is made double (connected to SOL.A and SOL.B) for respective sta- tions of the manifold. The optional specifi- cation permits mixture of single and double wiring. See p.1.10-198 for details.
Suffix “-XP” for the dust proof SI unit.(Except for SE, SG and SQ.)
Note 1) Specify “Mixed size/with port plug” by means of manifold specification form.Note 2) Refer to “Options” on p.1.10-198 for One-touch fittings in inch sizes.
Note 1) If specifying more than one option, please list alphabetically. Example) -BNSNote 2) Models with a suffix “-B” have check valves for prevention of back pressure at all ma- nifold stations. If not all stations need this check valve, specify the stations where check valves are installed by using a manifold specification form. Note 3) S kit of VQ0000 and all of VQ1000 are equipped with a DIN rail, so indicate suffix “-D”.Note 4) Specify wiring by the manifold specification form.
Note 1) The general type requires a transmission unit on CPU side.Note 2) Usable only for VQ1000.
OABCDEF1GHJ1J2KQR1R2V
Without SI unitWith general type, Series EX300
SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)SI unit for MEWNET, F System (Matsushita Electric Works Ltd.)SI unit for 16-point Uni-wire System (NKE)
SI unit for Remote I/O (RIO) System (Allen-Bradley Co.)SI unit for 16-point Uni-wire H System (NKE)SI unit for 16-point S-LINK System (Sunx)SI unit for 8-point S-LINK System (Sunx)
SI unit for T-LINK Mini System (Fuji Electric)SI unit for Device Net and Compo Bus/D (OMRON)SI unit for 16-point Compo Bus/S (OMRON)SI unit for 8-point Compo Bus/S (OMRON)SI unit for CC-LINK (Mitsubishi Electric)
Max. 16 stations
Max. 8
Max. 8
Max.16
Max. 16 stations
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
SAapplicable to Series EX300
SB applicable to MELSECNET/MINI-S3 Data Link
(Mitsubishi Electric Corp.)
T unit Can be connected with PLC I/O card for serial transmission. EX300-TMB1………For models of Mitsubishi Electric Corp. EX300-TTA1……… For models of OMRON Corp. EX300-TFU1……… For models of Fuji Electric Company Ltd. EX300-TOO1………For general models ∗ Up to 32 points per unit. 16 outputs.
Master station: PLC made by Mitsubishi Electric Corp. Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 ∗ Max.64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.
LED namePOWER
RUNRDSD
ERROR
DetallsLighting when power is turned ON
Lighting when data transmission withthe master station is normal
Lighting during data receptionLighting during data transmissionLighting when reception data error occurs.
Lighting off when the error is corrected.
LED nameRUN/ERROR
TRD
DetallsBlinking when received data is normal;
Lighting when data is abnormal
Lighting during data reception
SDA SDB SG RDA RDB FG24V 0V
POWER RUN SD RD ERR
STATION NO.
ù10 ù1
24V 0V S1 S2 SG R1 R2 FG
RUNERR
TRD
ADDRESS NO.
Item
External power supply
Specifications
24V DC, +10%, –5%
Current consumption(Internal unit)
SA, SB, SD, SE, SF, SG, SJ, SK, SQ, SR: 0.1ASC: 0.3A
Nam
e o
f te
rmin
al b
lock
(LE
D)
No
te
… …
Note 1) Refer to p.1.10-198 for details.
1.10-187
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Sl unit output and coil numbering
How to Order Valve
<Wiring example 1> <Wiring example 2> Mixed wiring is optional. Use the manifold specification from to specify.
VQ0000
VQ1000
Metal
Rubber
Plug leadunit
51
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center (VQ1000 only)
12345
01
Series
01
Seal
Configuration
Non-locking push style
Push-locking slotted style
Push-locking lever style (1)
–BC
Manual override
24V DC; With indicator light and surge voltage suppressor5
Coil voltageBody
VQ 1 1 1 0 Y 5 LO
VQ0000
VQ1000
L plug connetor without connector
M plug connector without connector
VQ0000 VQ1000
LOMO
Electrical enty Note 1) Availabie only for VQ1000.
Note) Plug connector and lead wire layers are attached to the manifold.
Sl unitoutput No.
Sl unitoutput No.
0 1 2 3 4 5 6 7 8 9
A B A B A Void A Void A B
Stations Stations1 2 3 4 5
Double wiring (Standard)
0 1 2 3 4 5 6 7
A B A B BA A A
1 2 3 4 5
Single/Double mixed wiring (Option)
Note) S kit requires connector ass'y when increasing valve stations.
Refer to “Options” on p.1.10-198.
How to Order Manifold Ass'y
Specify valve and option nos. below the manifold base no.
(Example)
Write sequentially from the 1st station on the D side.When part nos. written coll-ectively are complicated, specify by using a manifold specifi- cation form.
Add prefix “∗ ” to parts nos. of the solenoid valves, etc.
Serial transmission unit kit VV5Q12-08C6SA-D···1 set –Manifold base No.∗ VQ1110-5LO············4 sets–Valve No. (Stations 1 to 4)∗ VQ1210-5LO············4 sets–Valve No. (Stations 5 to 8)
Specification
Standard
Highpressure
Lowwattage
Pilot valveSymbol
–
DC
(1.0W)
(1.5W)
(0.5W)
H
Y
SC applicable toSYSBUS Wire System (OMRON)
SD applicable to Satellite I/O Link System (Sharp)
Master station unit: OMRON's PLC SYSMAC Series C(CV) C500-RM201, C200H-RM201∗ Max. 32 units, transmission terminal connected (Max. 512 points) 16 outputs
Master station unit: Sharp's PLC New Satellite Series W ZW-31LM New Satellite Series JW JW-23LM, JW-31LM∗ Max. 31 units, I/O slave stations connected (Max. 504 points) 16 outputs
LED namePOWER
RUN
DetailsIt lights when power is turned ON.
It ligths when power is turned ON and slave stantions are in normal operation.
LED name
RUN
T/RERR
DetailsIt lights when transmissions is normal
and PLC is in the operation mode.It blinks when transmission is normal.It lights when transmission is abnomal. ERROR
It ligths when slave slation switch setting is abnormal, communication is abnormal, master slation's PLC is at rest, and slave station unit is out of order.
R.SETHOLD
It lights when control input is made for the master station.
L1 L2 SG L1 L2 SG24V 0V
POWER RUN SD RD ERR
STATION NO.
ù10 ù1
24V 0V + – + – FG
RUNERR
TRD
ADDRESS NO.
Sl u
nit
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Sl u
nit
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Dou
ble
Nam
e o
f te
rmin
al b
lock
(L
ED
)N
ote
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-188
L1L2L3L4
146.755.7225
235.5
257.466.4237.5248
368.177.1250
260.5
478.887.8250
260.5
589.598.5262.5273
6100.2109.2275
285.5
7110.9119.9287.5298
8121.6130.6300
310.5
9132.3141.3312.5323
12164.4173.4337.5348
13175.1184.1350
360.5
14185.8194.8362.5373
15196.5205.5375
385.5
16207.2216.2387.5398
10143152325
335.5
11153.7162.7325
335.5
Dimensions (mm)
VQ0000/1000Kit (Serial Transmission Unit)S
nL
VQ0000
Equation L1=10.7n+36, L2= 10.7n+45 n: Station (Max. 16)
Manifold S kit …………………………SV5Q05M, #6 Valve 2 position single ……………SV5Q05V, #7 2 position double……………SV5Q05V, #8 3 position closed center ……SV5Q05V, #9 3 position exhaust center …SV5Q05V, #9
1.10-189
182.5
162.5173
293175
185.5
3103.5187.5198
4114200
210.5
5124.5200
210.5
6135
212.5223
7145.5225
235.5
8156
237.5248
9166.5250
260.5
12198275
285.5
13208.5287.5298
14219300
310.5
15229.5312.5323
16240325
335.5
10177
262.5273
11187.5275
285.5
Dimensions (mm)
VQ1000
L1L2L3
nL
Note) Manifolds with SI unit for Matsushita’ s MEWNET FP and Allen Bradley Co.’s model are the same with L4 and L5 dimensions of dust proof SI unit.
Equation L1=10.5n+72 n: Station (Max.16)
Dust proof SI unit: L4=L3+25 L5=L4+25
Manifold S kit ………………………SV5Q12M, #6 Valve 2 position single…………SV5Q12V, #7 2 position double ……… SV5Q12V, #8 3 position…………………SV5Q12V, #8
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-192
VQ 0000/1000 Plug Lead UnitBase Mounted
Manifold Options/For VQ1000
When the same manifold is to be used for different pres-sures, individual SUP spacers are used as SUP ports fordifferent pressures. (One station space is occupied.)Block both sides of the station, for which the supply pre-ssure from the individual SUP spacer is used, with SUPblock plates. (See the application ex.)∗ Specify the spacer mounting position and SUP block plate position by means of the manifold specification form. The bolck plate are used in two places for one set. (Two SUP block plates for blocking SUP station are attached to the individual SUP spacer.)
Individual EXH spacerVVQ1000-R-2-C6
When valve exhaust affects other stations due to the circuit configuration, this spacer is used for individual valve exha-ust. (One station space is occupied.)Block both sides of the individual valve EXH station.(See the application ex.)∗ Specify the mounting position, as well as EXH block base
or EXH block plate position by means of the using manifold speciffcation form. The block plate are used in two places for one set.
Check valve for prevention of back pressure assembly [-B]VVQ1000-18A
It prevents cylinder malfunction caused by other valveexhaust. Insert it into R (EXH)port on the manifold sideof a valve which is affected. It is effective when a single-action cylinder is used or an exhaust center type solenoid valve is used.Note) When a check valves for back pressure prevention is desired to be installed only in desired manifold stations, write celarly the part No. and specify the number of stations by using manifold specification form.
∗ When ordering assembiles incorporated with a manifold, add suffix “–B” to the manifold No.
<Precautions>1. The check valves prevention of back pressure ass'y is as-
sembly parts with a check valve structure. However, as
slight air leakage is allowedfor the back pressure, take the exhaust air will not be
throttled at the exhaust port.2. When a check valve for pre-
vention of back pressure is mounted, the effective orifice
of the valve will decrease by about 20%.
Blank plate assemblyVVQ1000-10A-1
JIS Symbol
It is mounted on a specific position of a manifold blockfrom which a valve is removed for maintenance or inwhich a spare valve is planned to be mounted.
Individual SUP spacerVVQ1000-P-2-C6
SUP/EXH block plateVVQ1000-16A-2
When high and low, different pressures are supplied toone manifold, a SUP block plate is inserted between thestations under different pressures. When a valve exhaustaffects other stations due to the circuit configuration, thisplate is also used between the stations where exhaustshould be separated. It is also used for individual exhaustby combining an EXH block plate with an individual EXHspacer. (2 EXH plates are necessary for 1 station.)Note) The SUP/EXH block plate is common.∗ Specify the atation's qty and position by using a manifold specification form.
When using block plates for SUP/EXH passage, indication label for confirmation of the blocking position from outside is attached. (one label for each)
∗ When ordering a block plate incorporated with themanifold no., a block indication label is attached to the
manifold.
<Blocking indication label>
Manifold options………SV5Q12OP, #1 to #11
1.10-193
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Name plate [-N∗]VVQ1000-N2-Station (1 to Max. stations)
It is transparent resin plate for placing a label thatindicates solenoid valve function, etc.Insert it into the groove on the side of the end plateand bend it as shown in the figure.
Port plugVVQ0000-58A
2 stations matching fitting assemblyVVQ1000-52A-C8
The plug is used to block the cylinder port when usinga 4 port valve as a 3 port valve.
Elbow fitting assemblyVVQ1000-F-L
Built-in silencer, Direct exhaust [-S]
It is used for piping that extends upward or downward
from the manifold.
When not mounting it to all manifold stations, cleary write
the elbow type fitting ass'y no. and specify the station's
qty and position by manifold specifications.
This is an exhaust port on the manifold end plate. The built-in silencer exhibits an excellentnoise suppression effect. (silencing effect: 30dB)Note) A large quantity of drainage generated in the air source results in exhaust of air together with drainage.
See p.1.10-196 for maintenance.
For driving a cylinder with a large bore, valves for twostations are operated to double the flow rate. This ass'y for the cylinder port is used in that case. The ass'y is equipped with One-touch fittings for a ø8 bore.∗ The bore for the manifold no. is “CM.” Clearly indicate
the 2-station matching fittings ass'y No., and specify the number of stations and positions by means of the manifold specifications.
This silencer is inserted into the EXH port (One-touchfittings) of the common exhaust type.
Silencer (EXH port)
C3C4C6M5
∗ When ordering assemblies incorporated with a manifold, add suffix “–S” to the manifold No.
∗ When ordering assemblies incorporated with a manifold, add suffix “–N” to the manifold No.
∗ When ordering assemblies incorporated with a manifold, indicate “L” or “B” for the manifold port size.
∗ When ordering a plug incorporated with a manifold, indicate “CM” for the port size in the manifold no., as well as, the mounting position and number of stations and cylinder port mounting positions, A and B, by means of the manifold spe- cification form.∗ Lightly screw an M3 screw in the port plug hole and pull it for removal.
Fittingssize ød Model
KQP-23-X19KQP-04-X19KQP-06-X19KQP-08-X19
A
161618
20.5
L
31.5323539
D
3.268
10
Fittingsize ød
8
Model
AN200-KM8
Series
VQ1000
A
59.3
L
77.8
D
22
Silencingeffect dB
30
Dimensions (mm)
Dimensions (mm)
Blank plug (For One-touch fittings)
KQP- -X19
It is inserted into an unused cylinder port and SUP/EXHports.The minimum order quantity is 10 pcs.
23040608
Color: White
Manifold options…………SV5Q12OP, #4 to #11
3.2468
Effective area(mm2)(Cv)
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-194
Double check block (Separate style): For VQ0000, VQ1000VQ1000–FPG–It is used on the way of the secondary side piping keepthe cylinder in the intermediate position for a long time.Combining a double check block with a built-in pilot typedouble check valve and a 3 position EXH centersolenoid valve will enable the cylinder to stop in themiddle or maintain its position for a long time.The combination with a 2 position single/double sole-noid valve will permit this block to be used for preventingthe dropping at the cylinder stroke end when the SUPresidual pressure is released.Specifications
Max. operating pressureMin. operating pressureAmbient and fluid temperatureEffective area (Cv factor)Max. operating fraquency
0.8MPa0.1MPa
–5 to 50˚C2.7mm2 (0.15)
180CPM
<Check Valve OperationPrinciple>
VVQ1000-FPG-02 1set∗ VQ1000-FPG-C6M5-D 2 pcs.
Note) As per JISB8375-1981 (Supply pressure: 0.5 MPa)
Dimensions
Single Manifold
L1L2L3
3150
60.5
1 2 3 4 5 6 7 8 9 10 11 1242
62.573
5375
85.5
6487.598
75100110.5
86112.5123
97125135.5
108125135.5
119137.5148
130150160.5
141162.5173
152175185.5
nL
L1L2L3
163187.5198
13 14 15 16 17 18 19 20 21 22 23 24174187.5198
185200210.5
196212.5223
207225235.5
218237.5248
229250260.5
240250260.5
251262.5273
262275285.5
273287.5298
284300310.5
nL
Dimensions Equation L1=11n+20 n: Station (Max. 24)
How to Order
Double check block
VQ1000–FPG– FM5C4
Manifold
IN side port size OUT side port sizeOption–
D
N
NoneWith blacket
DIN rail mounting(for manifold)
With name plateNote 1) When specifying more than one option, please list alpha- betically. Example)-DIN
M5C3C4C6
M5 threadOne-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6
C4C6
One-touch fitting for ø4One-touch fitting for ø6
VVQ1000–FPG– 06Stations01
16
1 station
16 stationsVVQ1000-FPG-06………6 stations of manifold∗ VQ1000-FPG-C4M5-D, 3 sets∗ VQ1000-FPG-C6M5-D, 3 sets
<Example>
<Example>
F
Manifold Option Parts/VQ0000/VQ1000
Caution Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder
from stopping for a long time. Check the leakage using neutral household detergent, such as dish washing soap. Also, check the cylinder’s tube gasket, piston packing and rod packing for leakage.
Since One-touch fittings allow slight air leakage, screw piping (with M5 thread) is recommended when stopping the cylinder in the middle for a long time, .
Combining double check block with 3 position closed center or pressure center solenoid valve will not work.
M5 fitting assembly is attached, not incorporated into the double check block. After screwing in the M5 fittings, mount the ass’y on the double check block. Tightening torque: 0.8 to 1.2Nm If the exhaust of the double check block is throttled too much, the cylinder may not operate properly and
may not stop intermediately.
… …
Double check block
Note)
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-195
Precautions
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
In case of VQ1000, the standard model is equipped with an indicator light and surge voltage suppressor. The lighting positions are concentrated on one side for both single solenoid styleand double solenoid style. In the double solenoid style, A-side and B-side energization are indicated by two colors which match the colors of the manual overrides.
How to Mount/Remove Solenoid Valve
q Loosen the clamp screw until it turns freely. (The screw is captive)w Lift the coil side of the valve body while pressing down slightly on the screw head and remove it from the clamp bracket. When the screw head cannot be pressed easily, gently press the area near the manual override of the valve.
q Press down on the clamp screw. Clamp bracket A opens. Diagonally insert the hook on the valve end plate side into clamp B.w Press the valve body downward. (When the screw is released, it will be locked by clamp bracket A.)e Tighten the clamp screw. (Appropriate clamping torque: 2.5 to 0.35Nm)
Note) A-side energization: A light (orange) illuminates. B-side energzation: B-light (green) illuminates.
Equipped with a wiring error prevention (stop diode) mechanism and a surge absorp- tion (surge absorption diode) mechanism.
Manual Override
Without an electric signal for the solenoid valve the manual override is used for switching the main valve.Standard model: Non-locking push styleOption: Push-locking slotted/lever style
VQ0000 (DC) VQ1000 (DC)Single solenoid
VQ1000Double solenoid
How to remove
Non-locking push style
Push-locking slotted style <Opiton>
Push-locking lever style <Option>
Push down on the manual override button with a small screwdriver until it stops.Release the screwdriver and the manual override will return.
Push down on the manual override button with a small screwdriver until it stops. While down,turn clockwise by 90˚ to lock it.Turn it counterclockwise to release it.
Push down on the manual override button with a small screwdriver or with your fingers until it stops. Turn clockwise by 90˚ to lock it. Turn it counter-clockwise to release it.
Indicator Light and Surge Voltage Suppressor
How to mount
1) Protect O rings from scratches and dust to prevent air leakage.2) The tightening torque for inserting fittings to the M5 thread assembly should be 0.8 to 1.2Nm. When inserting operation is difficult, the M5 thread assembly can be removed from the manifold block, attach the fitting, and then reinstall to the manifold.3) The minimum order quantity is 10 pcs.
Replacement of Cylinder Port Fittings
The cylinder port fitting are in a cassette for easy replacement. The fittings are blocked by a clip inserted from the top of manifold. Remove the clip with a screwdriver to remove fittings. For replacement, insert the fitting assembly unitl it strikes against the inside wall and then re-insert the clip to specified position.
Applicable tube O.D
Applicable tube ø3.2Applicable tube ø4Applicable tube ø6M5 female thread
VVQ1000-51A-C3VVQ1000-51A-C4
VVQ1000-50A-C3VVQ1000-50A-C4VVQ1000-50A-C6VVQ1000-50A-M5
VQ0000Fitting ass'y No.
∗ Refer to “Options” on p.1.10-190 to 1.10-193 for other types of fittings.
VQ1000
∗ In case of VQ0000, solenoid and manual override on both sides.
∗ In case of VQ0000, solenoid and manual override on both sides.
1) Dust on the sealing surface of the gasket or solenoid valve can cause air leakage.2) In case of VQ0000, valve mounting screw clamping torque is 0.18 to 0.25Nm
Take off the valve andremove the clip.
Remove the clip after taking off the manifold.
Do not apply too much torque when turning the lock style manual override. (0.1Nm or less)
Caution
Warning
Caution
Caution Caution
Caution
Caution
––
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-196
PrecautionsBe sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
Mounting/Removing from the DIN Rail (VQ1000)
Removing
Mouting
1) Loosen the clamp screw on side (a) of the end plate on both sides.2) Lift side(a) of the manifold base and slide the end plate in the direction of w shown in the figure to remove.
1) Hook side (b) of the manifold base on the DIN rail.2) Press side (a) and mount the end plate on the DIN rail. Tighten the clamp screw on side (a) of the end plate. The appropriate tightening torque is 1.2 to 1.6Nm.
How to Use Plug Connector
Insert a socket into the square hole (Indicated +, –) of connector, push in thelead wire and lock by hanging the hook of socket to the seat of connector. (Pushing-in can open the hook and lock it automatically.) Then confirm the lock by lightly pulling on the lead wire.
Push the connector straightonto the pins of the solenoid,making sure the lip of the leveris securely positions in thegroove on the solenoid cover.
Crimp the lever against theconnector and pull the con-nector away from the solenoid.
Connection/Disconnection of Plug
Crimping the Lead Wireand Socket
Socket with Lead Wire Connection
For pulling-out the socket from the connector, pull out the lead wire with pushing the hook of socket by a stick with a fine point (ca.1mm). If the socket is re-used as it is, spread the hook tothe outside.
Disconnection
Peel 3.2 to 3.7mm of the tip oflead wire, enter the core wiresneatly into a socket and presscontact it by a press tool. Becareful so that the cover of leadwire does not enter into the corepress contacting part.
Built-in Silencer Replacement Element
Manifold Base Station Increasing Procedure(VQ1000)
A silencer element is incorporatedin the end plate on both sides of themanifold base. A dirty and chokedelement may reduce cylinder speedand cause malfunction. Clean orreplace the dirty element.
Element part No.
Remove the cover from the top of
the end plate and remove the old
element with a screwdriver, etc
ModelElement part No.
VQ0000
VVQ0000-82A-1
VQ1000
VVQ1000-82A-1Built-in Silencer,
Direct exhaust(-S)
∗ The minimum order quantity is 10 pcs.
q Loosen the clamp screw on the top surface of the end plate on one side.wTurn the manual override between the manifold blocks at the increasing location with a regular screwdriver, etc. couterclockwise.
e Slide the manifold base to the side where the screw is loosened. Make a clearance of 15mm or more.
r Mount the station-increasing manifold block ass'y and sole- noid valve on the DIN rail. Install it to the DIN rail by applying the hook on the (b) side of the mani- fold block and pushing down the (a) side.
t Slide the manifold bases with a slight clearance in-between and lock them by turning the manual override between the manifold blocks clockwise.y Tighten the screw on the top surface of the end plate,and thus station-increasing is completed. (Appropriate tightening torque is 1.2 to 1.6Nm)
Manifold block assemblyVQ1000
VVQ1000-1A-2-C3VVQ1000-1A-2-C4VVQ1000-1A-2-C6VVQ1000-1A-2-M5
Port size
One-touch fitting for ø3.2
One-touch fitting for ø4
One-touch fitting for ø6
M5 thread
CautionCaution
Caution
Enclosure IP65
Wires, cables, connectors, etc. used for models conforming to IP65 should also have enclosures equivalent to or of stricter rating than IP65.
Caution
Caution
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-197
Options
Different Number of Connector Pins
When an F kit or P kit with a different number of pins (standard pins: F=25; P=26) is desired, the cable assembly will not be provided. Place an order for the cable assembly separately. Select the desired number of pins and cable length from the cable assembly list.
Kit (D-sub connector) 15 pinF Kit (Flat cable connector) 10 pin, 16 pin, 20 pinP
How to Order Manifold How to Order Manifold
Stations
06 F SA DVV5Q12
Option
D
Option
How to orderD-sub connector, 15 pinConnector location–Side(horizontal)Without cable
06VV5Q12
1.5m
3m
5m
AXT100-FC10-1
AXT100-FC10-2
AXT100-FC10-3
17.2mm
AXT100-FC16-1
AXT100-FC16-2
AXT100-FC16-3
24.8mm
AXT100-FC20-1
AXT100-FC20-2
AXT100-FC20-3
30mm
10 pin 16 pin 20 pin
LocationPins
15 pin (Max. 7stations) suffix: UA suffix: SAF Kit F Kit
Top (vertical) Side (horizontal)
10 pin (Max. 4 stantions)
16 pin (Max. 7 stantions)
20 pin (Max. 9 stantions)
suffix: UA
suffix: UB
suffix: UC
suffix: SA
suffix: SB
suffix: SC
P Kit P Kit
∗ When using other commercially avaiable connectors, select models with strain relief that conform to MIL-C-83503.
Flat cable assembly
PinsLength(L)
PinsLength(L)
1.5m
3m
5m
AXT100-DS15-1
AXT100-DS15-2
AXT100-DS15-3
15 pin
∗ When using other commercially avaiable connectors, select models that conform to MIL-C-24308.
D-sub connector cable assembly
In the same way as the 25 pin (standard) products, the terminal No.1 for is SOL.A at the 1st stantion, the terminal No.9 for SOL.B at the 1st station, and the terminal No.8 for COM.
∗ In the same way as the 26 pin (standard) products, the terminal No.1 is SOL.A at the 1st station, the terminal No.2 for SOL.B at the 1st station, and two pins from the max. terminal numbers are for COM.
Wire color table by terminal number of D-sub connectorcable assembly
123456789101112131415
BlackBrownRed
OrangeYellowPinkBlueVioletGrayWhiteWhiteYellowOrangeYellowPink
–––––––
WhiteBlackBlackRedRedRed
BlackBlack
Dot markingLead wire colorTerminal No.
How to orderFlat cable, 20 pinConnector location–Side (horizontal)Without cable
Number ofstations
P SC
Kit/Electrical entry Kit/Electrical entry
Connector width (W)
LocationPins Top (vertical) Side (horizontal)
∗
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-198
Special Wiring Specifications
Negative COM Specifications[Series VQ110]
Regardless of the valve or option, the standard internal wiring for doublesolenoid capability is provided to each station of F/P/T/S kit.As made-to-order combinations of single and double wiring (connectedto SOL A, B) are available.
Indicate an option symbol, “–K,” for the manifold no. and be sure to specifythe mounting position and number of stations of the single and double wiring by means of the manifold specification form.
1. How to Order
2. Wiring specification
How to order manifold VV5Q05–08C4FU1–D K S
List option symbols in alphabetical order
With the A side solenoid of the 1st station as no.1 (meaning, to be connected tono.1 terminal), wires are connected in the order indicated by the arrow in the DWGwithout making any terminals vacant.
3. Max. number of stationsThe max. number of stations depends upon the number of solenoids. Assuming onefor a single and two for a double, determine the number of stations so thatthe total number is not more than the max. number given in the following table.
Order the valves and manifolds with negative COM specification as follows.
VQ1110
Negative COM specification
N 5M
F kit(D-sub connector)
T kit(Terminal block)
P kit(Flat cable connector)
S kit(Serial
transmission)Kit
Model
Max.number
F 25P
US P
26P
US P
16P
US BP
20P
US C P A
10P
USF
15P
US A S
16 14 16 16 14 8 8 16 16
Made to Order
∗ Series VQ050 has no polarity, so the negative common is applicable to standard models.
T1 T2
Note 1) Due to the limitation of internal wiring.
Inch-size One-Touch FittingThe valve with inch-size One-touch fittings is shown below.
VV5Q12 06 N7 PSO DOption
Kit/Electrical entry
Number of stations
Cylinder portsSymbol
Applicble tube O.D(Inch)
VQ0000
VQ1000A, Bport
Ø1/8" Ø1/4"Ø5/32" 10-32UNF(M5)
Mixedsize
NMM5TN7N3N1
Note) When inch-size fittings are selected for a cylinder port, use inch-size fittings for both P and R port.
P, R port size VQ0000…… ø1/4” VQ1000…… ø5/16”
Plug Connector Assembly Model
Connector assembly No.
F, P, and S kits need connector assembly when adding a valve station.Specify the style of valve and connector assembly.
Specifications No.Single
VQ0000(2 wire)
Double(latching)(3 wire)
Positive COM
Negative COM
Positive COM
Negative COM
AXT661-14A-F
AXT661-14AN-F
AXT661-13A-F
AXT661-13AN-FNote) Lead wire length: 300mm The parts numbers above are applicable to 2 to 10 stations.
11 to 16 stations: “AXT661- A(N)-F-425”.
(1) (1) (1)
1314
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-199
DIN Rail Mounting StyleEach manifold can be mounted on a DIN rail. Order it by indicating a DINrail mounting option symbol, “–D.” In this case, a DIN rail which is app-rox. 30mm longer than the manifold with the specified number of stationsis attached. Other than this, it is applicable for the following cases.
When DIN rail is unnecessary (C kit VQ0000 only)
Indicate the option symbol, “–DO,” for the manifold No.
Example)
VV5Q05–08C4C–D0SList option symbolsin alphabetical order
When using DIN rail longer than the manifold with specified number of stations (VQ0000/VQ1000)
When changing the manifold style into a DIN rail mounting (VQ0000 only)
When ordering DIN rail only (VQ0000 only)
Order brackets for mounting a DIN rail. (See Options on p.1.10-191)
No. VVQ0000–57A–5 2 pcs. per one set.
Example)
VV5Q05–08C4FU1–D09S
List option symbolsin alphabetical order
DIN rail for 9 stations
DIN rail No.: AXT100–DR–∗ Put no. in the square using the DIN rail dimensional table.
Refer to the each kit dimensional drawing for L dimension.
1 2 3 4 5 6 7 8 9 1023 35.5 48 60.5 73 85.5 98 110.5 123 135.5
No.L
No.L
No.L
No.L
11 12 13 14 15 16 17 18 19 20148 160.5 173 185.5 198 210.5 223 235.5 248 260.5
21 22 23 24 25 26 27 28 29 30273 285.5 298 310.5 323 335.5 348 360.5 373 385.5
31 32 33 34 35 36 37 38 39 40398 410.5 423 435.5 448 460.5 473 485.5 498 510.5
(mm) L=12.5 X n+10.5L dimension
Clearly indicate the necessary number of stations next to the option symbol. “D”for the manifold No.
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
VQ 0000/1000 Plug Lead UnitBase Mounted
1.10-200
Series Configuration Model
VQ0000plug lead
Single
Double
Closedcenter
Exhaustcenter
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
VQ0150
VQ0151
VQ0250
VQ0251
VQ0350
VQ0351
VQ0450
VQ0451
2.7
3.6
2.7
3.6
2.0
2.7
2.0
2.7
Response time (2) (ms)
12 or less
15 or less
10 or less
15 or less
20 or less
25 or less
20 or less
25 or less
15 or less
20 or less
13 or less
20 or less
26 or less
33 or less
26 or less
33 or less
50
65
Welght(g)Low wattage
ACStanderd: 1W
H: 1.5W
Effective area(1)
(mm2)(Cv)
Note 1) Cylinder port size C4: (VQ0000)Note 2) As per JIS8375-1981(supply pressure: 0.5 MPa; with indicator light and surge voltage
suppressor; clean air) The response time is subject to the pressure and quality of the air. The valves at the time of ON are given for double types.Note 3) Weight including sub-plate.
Standard Specifications
Model
Ambient and fluid temperature
Lubrication
Manual override
Impact/Vibration resistance (2)
Protection structure
Coil rated voltage
Allowable voltage
Coil insulation
Single
Double
3 position
Min. operating
pressure
Seal
Fluid
Max.operating pressure
Metal seal
Air/lnert gas
0.1MPa
0.1MPa
0.1MPa
0.15MPa
0.1MPa
0.2MPa
–10 to +50˚C
0.7MPa (High pressure type: 0.8MPa)
Not required
Non-locking push style/Push-locking slotted or lever style (Option)
150/30 m/s2
Dust proof
12, 24V DC, 100, 110, 200, 220V AC (50/60Hz)
±10% of rated voltage
Class B or equivalent
Rubber seal
Air/lnert gas
Power consumption
(Current value)
24V DC
12V DC
100V AC
110V AC
200V AC
220V AC
Valve
Solenoid
Note 1) Use dry air to prevent condensation when operating at low temperature.Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was
performed on the axis and right angle directions of the main valve and armature, for both energized and deenergized states.
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2,000 Hz. Test was performed at both energize and de-energized states to the axis and right angle directions
of the main valve and armature. (Value in the initial stage.)Note 3) Value for high pressure type (1.5W)Note 4) Value for low wattage type (0.5W)
For individual use of a single valve
VQ0000
Bas
e m
ou
nte
d
2 p
osi
tio
n3
po
siti
on
(3)
(3)
1W DC (42mA), 1.5W DC (63mA), 0.5W DC (21mA)
1W DC (83mA), 1.5W DC (125mA), 0.5W DC (42mA)
Inrush, Holding
Inrush, Holding
Inrush, Holding
Inrush, Holding
(3) (4)
(3) (4)
(0.15)
(0.2)
(0.15)
(0.2)
(0.11)
(0.15)
(0.11)
(0.15)
(1)
Series VQSingle Unit
1.10-201
Single Unit
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Wiring Specifications
The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Connector assembly
Lead wire length
AXT661-12AAXT661-14AAXT661-14A-6AXT661-14A-10AXT661-14A-20AXT661-14A-30
Ass'y part No.
Socket (3 pcs.)300mm600mm1000mm2000mm3000mm
Note) AXT661–31A–∗ for 100/110V AC, AXT661–34A–∗ for 200/220V AC.
Plug connector lead wire length
Example) Lead wire length 1000mm
VQ1110N-5LO ……… 3 pcs.
AXT661-14A-10………3 pcs.
Note) The length of the lead wire provided is300mm. When a valve with lead wire of
600mm or more is needed, specify both the valve without connector and the longer connector ass'y no.
Lead wire color
COM
( – )
( + )
SOL.A Black (Blue) [Red]
Red (Blue) [Red]
24VDC 200, 220100, 110
How to Order Valve
0 Y51 5 L C4VQ0Series VQ0000
Configuration12
2 position single2 position double
3 position closed center3 position exhaust center
34
Manual override– Non-locking push style
Push-locking slotted styleB
Sub-plate SUP/CYL ports–C3C4M5
Without subplateOne-touch fitting for ø3.2One-touch fitting for ø4
M5 threadNote) EXH port: M5 thread
Electrical entryGL
LOM
MO
Grommet (Except for AC)
L plug connector with lead wireL plug connector without connectorM plug connector with lead wireM plug connector without connector
Coil rated voltage123456
100V AC (50/60Hz)200V AC (50/60Hz)110V AC (50/60Hz)220V AC (50/60Hz)
24V DC12V DC
Seal01
MetalRubber ∗ Option
∗
Note 1) Refer to p.1.10-200 for AC.
Specification
Standard
Hightpressure
Lowwattage
Pilot valve (Option)Symbol
H
–
Y
DC AC(1.0W)
(1.5W)
(0.5W)
(1)
–
–
V AC V AC
1.10-202
Dimensions
2 position double: VQ02501
3 position closed center/exhaust center: VQ0 534
01
2 position single: VQ015 01
< >: AC
2 position single (M)…………… SV5Q05V, #72 position double (M)……………SV5Q21V, #8 Grommet: #10 and L3 position closed center (M)……SV5Q05V, #9 plug connector: #11 are3 position exhaust center ………SV5Q05V, #9 added.
Single Unit
1.10-204
Series VQConstruction/Component Parts, Replacement Parts
Construction: Plug-in Unit/VQ1000
Metal seal Rubber seal
Component PartsNo. Description
Body
Spool/Sleeve
Piston
Material
Zinc die cast
Stainless steel
Resin
Note
q
w
e
Component Parts
Replacement Parts
Pilot valve assembly
Pilot valve assembly Single
Double/3 position
r
t
VQ111 --1(H)(Y)
Voltage1 to 6
(1)
VQ131 -(H)(Y)
Voltage1 to 6
(1)
Replacement Parts
Note 1) (Y): 0.5W(H): 1.5W
No. Description
Body
Spool valve
Piston
Material
Zinc die cast
Aluminum/NBR
Resin
Note
q
w
e
Pilot valve assembly
Pilot valve assembly Single
Double/3 position
r
t
VQ111 --1(H)(Y)
Voltage1 to 6
(1)
VQ131 -(H)(Y)
Voltage1 to 6
(1)
Note 1) (Y): 0.5W(H): 1.5W
1.10-205
Construction
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Construction: Plug-in Unit/VQ2000
Metal seal Rubber seal
Component PartsNo. Description
Body
Spool/Sleeve
Piston
Material
Aluminum die cast
Stainless steel
Resin
Note
q
w
e
Component Parts
Replacement Parts
Pilot valve assembly
Pilot valve assembly Single
Double/3 position
r
t
VQ111 --1(H)(Y)
Voltage1 to 6
(1)
VQ131 -(H)(Y)
Voltage1 to 6
(1)
Replacement Parts
Note 1) (Y): 0.5W(H): 1.5W
No. Description
Body
Spool valve
Piston
Material
Aluminum die cast
Aluminum/NBR
Resin
Note
q
w
e
Pilot valve assembly
Pilot valve assembly Single
Double/3 position
r
t
VQ111 --1(H)(Y)
Voltage1 to 6
(1)
VQ131 -(H)(Y)
Voltage1 to 6
(1)
Note 1) (Y): 0.5W(H): 1.5W
1.10-206
Construction: Plug Lead Unit/VQ0000
Metal seal Rubber seal
Component PartsNo. Description
Body
Spool/Sleeve
Piston
Material
Aluminum die cast
Stainless steel
Resin
Note
q
w
e
Component PartsNo. Description
Body
Spool valve
Piston
Material
Aluminum die cast
Aluminum/NBR
Resin
Note
q
w
e
Replacement Parts
Pilot valve assemblyr
Replacement Parts
Pilot valve assemblyr
Note 1) (Y): 0.5W, (H): 1.5W DC only for G type.
LMG
VQ110P --1(H)(Y)
Voltage1 to 6
(1) LMG
VQ110P --1(H)(Y)
Voltage1 to 6
(1)
Note 1) (Y): 0.5W, (H): 1.5W DC only for G type.
Construction
1.10-207
Construction
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
Construction: Plug Lead Unit/VQ1000
Metal seal
Component PartsNo. Description
Body
Spool/Sleeve
Piston
Material
Zinc die cast
Stainless steel
Resin
Note
q
w
e
Component PartsNo. Description
Body
Spool valve
Piston
Material
Zinc die cast
Aluminum/NBR
Resin
Note
q
w
e
Replacement Parts
Pilot valve assembly
Pilot valve assemblyr
t
Replacement Parts
Pilot valve assembly
Pilot valve assemblyr
t
Rubber seal
Single
Double/3 position
VQ111 --1(H)(Y)
Voltage1 to 6
(1)
VQ131 -(H)(Y)
Voltage1 to 6
(1)
Single
Double/3 position
VQ111 --1(H)(Y)
Voltage1 to 6
(1)
VQ131 -(H)(Y)
Voltage1 to 6
(1)
Note 1) (Y): 0.5W(H): 1.5W
Note 1) (Y): 0.5W(H): 1.5W
1.10-208
Plug-in Unit/VQ1000
Manifold block ass'yD side end plate ass'y U side end plate ass'yHousing ass'y and SI unit
(F, P, L, S kit)
S k
itP
kit
F k
itL
kit
Exploded View of Manifold
1.10-210
Plug-in Unit/VQ2000
Manifold block ass'yD side end plate ass'y U side end plate ass'yHousing ass'y and SI unit
S k
itP
kit
F k
itL
kit
G k
it
(F, P, L, G, S kit)
Exploded View of Manifold
1.10-211
Exploded View of Manifold
<Housing Assembly and SI Unit>Housing Assembly and SI Unit No.
<Replacement Parts for Manifold Block >Replacement Parts
No. Ass'y No. Name Material NumberVVQ2000-80A-1VVQ2000-80A-2VVQ2000-80A-3VVQ2000-80A-4
<D Side End Plate Assembly>tyD Side End Plate Assembly No.
OptionElectrical entry Note 1) Specify as “RS” when both conditions are applicable.Note 2) The housing assembly and SI unit of F/P/G/S kit are not included. Separately place an order for q, w, eandr.Note 3) Consult SMC for dust tight/jet proof style (IP65).
<U Side End Plate Assembly>
<Manifold Block Assembly>
uU Side End Plate Assembly No. (For F/P/G/S kits)
VVQ2000–2A–1Option
iU Side End Plate Assembly No. (For L kit)
VVQ2000–2A–1–L
GasketPacking
Clamp screwClip
NBRNBR
Carbon steelStainless steel
12121212 Note) A set of parts containing 12 pcs.each are enclosed.
Note) 10 pcs. per one set. Note) 10 pcs. per one set.
oManifold Block Assembly No.
VVQ2000–1A– – –
Electrical entryPort size
<Fitting Assembly>!4Fitting Assembly No. (For cylinder port)
VVQ1000–51A–
Note) Tie-rod(2 pcs.) and lead wire ass'y for extensions are attached
!0
!1
!2
!3
Port size
!5Fitting Ass'y No. (For P, R ports)
VVQ2000–51A–C10Applicable tube ø10
FPLGS
For F kitFor P kitFor L kitFor G kitFor S kit
–R (1)
S (1)
Common EXHExternal pilotBuilt-in silencer, Direct exhaust
–RS
Common EXHExternal pilotBuilt-in silencer, Direct exhaust
F kit for 2 to 12 stations/Double wiringF kit for 13 to 24 stations/Double wiringF kit for 2 to 24 stations/Single wiringP, S kit for 2 to 12 stations/Double wiringS kit for 13 to 24 stations/Double wiringS kit for 2 to 24 stations/Single wiringL0 kit Stations (1 to 8)L1 kit Stations (1 to 8)L2 kit Stations (1 to 8)
F1F2F3P1P2P3
L0L1L2
One-touch fitting for ø4One-touch fitting for ø6One-touch fitting for ø8
C4C6C8
Applicable tube ø4Applicable tube ø6Applicable tube ø8
C4C6C8
Note 1) The !5 fitting assembly is included.Note 2) The housing assembly and SI unit of F/P/G/S kit are not included. Separately place an order for q, w, eandr.Note 3) Consult SMC for dust tight/jet proof style (IP65).
Enclosure–W
Dust-proofDust-resistant/jet-proof (IP65)
VVQ2000–3A–1 –
No. Manifold No. Name(SA kit)(SB kit)
(SBB kit)(SC kit)(SD kit)(SE kit)
(SF1 kit) (SG kit)(SH kit)(SJ1 kit)(SJ2 kit)(SK kit)(SQ kit)(SR1 kit)(SR2 kit)(SV kit)P kitF kitGkit
USUS
EX320-S001(-XP)(1) [EX323-S001](2)
EX120-SMB1(-XP)(1) [EX123-SMB1](2)
[EX124-SMB1](3)
EX120-STA1(-XP)(1) [EX123-STA1](2)
EX120-SSH1(-XP)(1) [EX123-SSH1](2)
EX120-SPA1EX120-SUW1(-XP)(1)[EX123-SUW1](2)
EX120-SAB1EX120-SUH1(-XP)(1) [EX123-SUH1](2)
EX120-SSL1(-XP)(1) [EX123-SSL1](2)
EX120-SSL2(-XP)(1) [EX123-SSL2](2)
EX120-SFU1(-XP)(1) [EX123-SFU1](2)
EX120-SDN1 [EX124-SDN1](2)
EX120-SCS1(-XP)(1) [EX124-SCS1](2)
EX120-SCS2(-XP)(1) [EX124-SCS2](2)
EX120-SMJ1(-XP)(1) [EX124-SMJ1](2)
AXT100-1-P (4)
AXT100-1-F (4)
AXT100-1-GU20
US
US
General style SI unit, Series EX300SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)SI unit for MELSECNET/MINI-S3 Data Link System (2 power supply lines) (Mitsubishi Electric)SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)SI unit for MEWNET-F System (Matsushita Electric Works Ltd.)SI unit for 16 point Uni-wire System (NKE)SI unit for Remote I/O (RIO) System (Allen-Bradley Co.)SI unit for 16 point Uni-wire H System (NKE)SI unit for 16 point S-LINK System (Sunx)SI unit for 8 point S-LINK System (Sunx)SI unit for T-LINK Mini System (Fuji Electric)SI unit for Device Net and Compo Bus/D (OMRON)SI unit for 16 point Compo Bus/S (OMRON)SI unit for 8 point Compo Bus/S (OMRON)SI unit for CC-LINK (Mitsubishi Electric)Flat cable housing ass'y =Number of pins: 26, 20,16,10D-sub connector housing ass'y =Number of pins: 25, 15Flat cable housing ass'y with terminal block
Note 1) Suffix “–XP” for dust-proof SI unit. Note 2) Dust tight/jet proof style (IP65)Note 3) SBB kit is usable only for dust tight/jet proof style (IP65).Note 4) Top entry connector for FU and PU while side entry connector for FS and PS.
q
w
e
r
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
1.10-212
Plug Lead Unit/VQ0000
Manifold block ass'y D side end block ass'yTie-rod U side end block ass'y Housing ass'y and SI unit Note 3)
(F, P, C, S kit)
∗ Refer to the instruction manual for the way of increasing stations.
Note 1) S kit is composed of a flat cable housing ass'y (AXT100-2-PS20) of q SI unit and w P kit (20 pin).Note 2) Since no connector ass'y is included, order it separately. (See p.1.10-198)Note 3) Housing ass'y is not used for a C kit.Note 4) A DIN rail clamping bracket is attached to each.
S k
itP
kit
F k
itT
kit
S k
itP
kit
F k
itT
kit
Exploded View of Manifold
1.10-213
Exploded View of Manifold
<Housing Assembly and SI Unit>Housing Assembly and SI Unit No.
No. Manifold No. Name
(SA kit)
(SB kit)
(SC kit)
(SD kit)
(SF1 kit)
(SH kit)
P kit
F kit
T kit
T kit
USUS
EX330-S001
EX130-SMB1
EX130-STA1
EX130-SSH1
EX130-SUW1
EX130-SUH1
AXT100-2-P (2)
AXT100-2-F (2)
AXT100-2-TB1 (4)
AXT100-2-TB2 (4)
US
US
General style SI unit
SI unit for MELSEC-A (Mitsubishi Electric)
SI unit for SYSMAC (OMRON)
SI unit for New Satellite (Sharp)
SI unit for 16 point Uni-wire System (NKE)
SI unit for 16 point Uni-wire H System (NKE)
Flat cable housing ass'y =Number of pins: 26, 20, 16, 10
D-sub connector housing ass'y =Number of pins: 25, 15
Terminal block assembly (8 terminals)
Terminal block assembly (8 terminals)
<Replacement Parts for Manifold Block>Replacement Parts
No. Ass'y No. Name Material Number
VVQ0000-80A-5-2
VVQ0000-80A-5-4
<D Side End Plate Assembly>yD Side End Plate Assembly No.
VVQ0000–3A–5–Option
Note) 2 bolts per one set.
<U Side End Plate Assembly>
<Manifold Block Assembly>
uU Side End Plate Assembly No.
VVQ0000–2A–5–Option
Packing
Clip
NBR
NBR
12
12 Note) A set of parts containing 12 pcs. each is enclosed.
Note) 10 pcs. per one set. Note) 10 pcs. per one set.
iManifold Block Assembly No.
VVQ0000–1A–5–Port size
<Fittings Assembly>!1Fittings Assembly No. (For cylinder port)
VVQ0000–50A–Port size
<Tie-rod Bolt>!3Tie-rod Bolt
VVQ0000–103A–5–Stations
!2Fitting Ass'y No. (For P, R ports)
VVQ1000–50A–C6Applicable tube ø6
(1)
Note 1) S kit is composed of a flat cable housing ass'y (AXT100-2-PS20) of q SI unit and w P kit (20 pin). Order AXT100-2-PS20 separately.Note 2) Top vertical entry connector for FU and PU while side (horizontal) entry connector for FS and PS.Note 3) Since no connector assembly is included, order it separately. (See p.1.10-198)Note 4) In case of standard specifications and double wiring. r is for 1 to 4 stations and t is for 5 to 8 stations.
Note) The !2's fitting assembly is included.Common EXHBuilt-in silencer, Direct exhaust
–S
Common EXHBuilt-in silencer, Direct exhaust
–S
One-touch fitting for ø3.2One-touch fitting for ø4M5 thread
C3C4M5
Applicable tube ø3.2Applicable tube ø4
C3C4
For 1 stationFor 2 stations
For 16 stations
12
16
q
w
e
r
t
o
!0
… …
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ
1.10-214
Plug Lead Unit/VQ1000
Manifold block ass'yAir SUP/EXH block ass'y Air SUP/EXH block ass'yD side end block ass'y U side end block ass'yHousing ass'y and SI unit (3)
(F, P, T, S kit)
∗Refer to the instruction manual for the way of increasing stations
Note 1) S kit is composed of a flat cable housing ass'y (AXT100-2-PU20) of q SI unit and w P kit (20 pin).Note 2) Since no connector ass'y is included, order it separately. (See p.1.10-198)Note 3) Housing ass'y is not used for a C kit.Note 4) A DIN rail clamping bracket is attached to each.
S k
itP
kit
F k
itT
kit
Exploded View of Manifold
1.10-215
Exploded View of Manifold
<Housing Assembly and SI Unit>Housing Assembly and SI Unit No.
<Replacement Parts for Manifold Block>Replaceable Parts
No. Ass'y No. Name Material NumberVVQ1000-80A-1VVQ1000-80A-2-2VVQ1000-80A-3VVQ1000-80A-2-4
<D Side End Plate Assembly>yD Side End Plate Assembly No.
VVQ1000–3A–2
<Air Supply/EXH Block Assembly>
<Manifold Block Assembly>
iAir Supply/EXH Block Assembly No.
VVQ1000–PR–2–C8–Option
<U Side End Plate Assembly>uU Side End Plate Assembly No.
VVQ1000–2A–2
Note) The !5's fitting assembly is included.
GasketO ring
Clamp screwClip
NBRNBR
Carbon steelStainless steel
12121212
Note) A set of parts containing 12 pcs. each is enclosed.
Note) 10 pcs. per one set. Note) 10 pcs. per one set.
oManifold Block Assembly No.
VVQ1000–1A–2–Port size
<Fitting Assembly>!4Fitting Assembly No. (For cylinder port)
VVQ1000–50A–
!0
!1
!2
!3
Port size
!5Fitting Assembly No. (For P, R ports)
VVQ1000–51A–C8Applicable tube ø8
Note 1) S kit is composed of a flat cable housing ass'y (AXT100-2-PU20) of q SI unit and q P kit (20 pin). Order AXT100-2-PV20 separately.Note 2) Top (vertical) entry connector for FU and PU while side (horizontal) entry connector for FS and PS.Note 3) Since no connector assembly is included, order it separately. (See p.1.10-198) Contact SMC for 200/220VAC specifications.Note 4) In case of standard specifications and double wiring, r is for 1 to 4 stations and t is for 5 to 8 stations.
Common EXHBuilt in Silencer, Direct exhaust
–S
One-touch fitting for ø3.2One-touch fitting for ø4One-touch fitting for ø6M5 thread
C3C4C6M5
Applicable tube ø3.2Applicable tube ø4Applicable tube ø6M5 thread
C3C4C6M5
No. Manifold No. Name(SA kit)(SB kit)(SC kit)(SD kit)(SE kit)(SF1 kit)(SG kit)(SH kit)(SJ1 kit)(SJ2 kit)(SK kit)(SQ kit)(SR1 kit)(SR2 kit)(SV kit)P kitF kitT kitT kit
USUS
EX321-S001EX121-SMB1EX121-STA1EX121-SSH1EX121-SPA1EX121-SUW1EX121-SAB1EX120-SUH1EX121-SSL1EX121-SSL2EX121-SFU1EX121-SDN1EX121-SCS1EX121-SCS2EX120-SMJ1AXT100-2-P (2)
AXT100-2-F (2)
AXT100-2-TB1 (4)
AXT100-2-TB2 (4)
US
US
General style SI unit, Series EX300SI unit for MELSECNET/MINI-S3 Data Link System (Mitsubishi Electric)SI unit for SYSBUS Wire System (OMRON)SI unit for Satellite I/O Link System (Sharp)SI unit for MEWNET-F System (Matsushita Electric Works Ltd.)SI unit for 16 point Uni-wire System (NKE)SI unit for Remote I/O (RIO) System (Allen–Bradley Co.)SI unit for 16 point Uni-wire H System (NKE)SI unit for 16 point S-LINK System (Sunx)SI unit for 8 point S-LINK System (Sunx)SI unit for T-LINK Mini System (Fuji Electric)SI unit for Device Net and Compo Bus/D (OMRON)SI unit for 16 point Compo Bus/S (OMRON)SI unit for 8 point Compo Bus/S (OMRON)SI unit for CC-LINK (Mitsubishi Electric)Flat cable housing ass'y =Number of pins: 26, 20, 16, 10D-sub connector housing ass'y =Number of pins: 25, 15Terminal block assembly (8 terminals)Terminal block assembly (8 terminals)
q
w
e
r
t
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VP4
VQ4
VQZ
VQD
VZS
VFS
VS
VS7
VQ