Medium_Voltage (Oman Cables)

82

description

13.8KV cable specification given herein provided by Oman cables Saudi Arabia.

Transcript of Medium_Voltage (Oman Cables)

  • OCI/PBMVC/REV.001/010410

    1

    Recipient of Best Industry Trophy for the year 1991, 1992, 1996, 1997 & 2005

  • OCI/PBMVC/REV.001/010410

    2

    OMAN CABLES INDUSTRY (SAOG)

    Oman Cables Industry (SAOG) develops, manufactures and markets a totally integrated product line of Medium Voltage Cables for a diverse variety of technological applications.

    OCI was established in 1984 by the current Chairman, Mr. Mustafa Bin Mukhtar and the Vice Chairman & Managing Director, Mr. Hussain Bin Salman. Located in Rusayl, the Sultanates largest industrial complex, the company has grown by turnover into one of the top ten industrial companies in Oman.

    The company offers an unrivaled experience and a vast product range developed organically at the leading edge of technology. It manufactures a variety of products, which include Medium Voltage power cables, Low Voltage power & control cables, Instrumentation cables, Pilot cables, Overhead power transmission line conductors, Building wires & Flexible cables. It can also offer cables with special features like flame retardant properties, low smoke & fume (LSF or LSOH/LSZH) properties, cables with anti-termite treatment, UV resistant outer sheath, etc., suitable for different types of applications or environmental conditions.

    OCI holds s e v e r a l i m p o r t a n t international approvals and manufactures its products in acco rdance

    with relevant IEC, VDE, CENELEC, and British Standard specifications. The quality management system is accredited to ISO 9001 by TUV of Germany and BASEC (British Approvals Service for Electric Cables) of UK.

    OCI has won His Majesty Sultan Qabooss trophy for best industry 5 times - in 1991, 1992, 1996, 1997 & 2005. The company was judged on many factors including product quality, training & safety,sales turnover, export,

    financial strength, use of local manpower & resources and others.

    OCI has maintained an enviable growth record year on year. The products manufactured by OCI are sold not only in the region but also to Australia, Japan, South Korea, East & West African countries, Europe & UK.

    They have been installed in variety of applications including - Power plants, Sub-stations, Oil refineries, Fertilizer complexes, Petroleum & Gas handling facilities, Hospitals, Shopping Malls, Hotels, Airports, etc.

    The company is driven by a central philosophy based upon 3 key factors - PARTNERSHIP, INNOVATION and QUALITY. We take pride in our ability to offer products to each of our customers by meeting their specific needs - quickly, efficiently & with an assurance of product quality.

    This brochure gives details of the more commonly used types of Medium Voltage cables with

    options of type of conductor & armouring. However we can also offer cables with construction different from those covered in this brochure as per relevant national or international standards or meeting customers specific requirement.

  • OCI/PBMVC/REV.001/010410

    3

    PRODUCT RANGE

    VOLTAGE GRADE : 3.6/6/7.2 kV TO 18/30/36 kV (uo/u/um) as per IEC-60502-2 (EQUIVALENT 3.8/6.6/7.2 kV TO 19/33/36 kV - (Uo/U/Um) AS PER BS 6622)

    CONDUCTOR : COPPER OR ALUMINIUM

    CONDUCTOR SIZE : 25 TO 1000 SQ MM

    SPECIFICATION : IEC 60502 PART 2, BS 6622, OR ANY OTHER INTERNATIONAL SPECIFICATION COVERING ABOVE VOLTAGE RANGE

    Uo : NOMINAL PHASE TO EARTH VOLTAGE

    U : NOMINAL PHASE TO PHASE VOLTAGE

    Um : MAXIMUM PHASE TO PHASE VOLTAGE

    SPECIAL FEATURES

    OCI CAN ALSO OFFER CABLES WITH DIFFERENT SHEATHING, SCREENING, TAPING & ARMOURING OPTIONS AS PER CUSTOMERS SPECIFIC REQUIREMENTS. WE CAN ALSO OFFER CABLES SUITABLE FOR SUPERIOR FIRE PERFORMANCE CHARACTERISTICS AS WELL AS WITH LOW SMOKE & FUME (LSF or LSOH/LSZH) PROPERTIES. SPECIAL FEATURES LIKE LONGITUDINAL WATER SEALING OF CONDUCTORS & CU SCREENS, RADIAL WATER SEALING OF CU SCREENS AS WELL AS DIFFERENT COLOUR OF OUTER SHEATH CAN BE PROVIDED ON REQUEST.

    THE CABLE DESIGN IN THIS CATALOGUE CONFORMS TO IEC 60502 PART 2 & IN MOST CASES TO BS 6622. HOWEVER IF REQUESTED, WE CAN SEPARATELY OFFER GUARANTEED TECHNICAL PARTICULARS FOR CABLES AS PER DIFFERENT INTERNATIONAL SPECIFICATIONS OR SPECIFIC CUSTOMER NEEDS.

  • OCI/PBMVC/REV.001/010410

    4

    OCI/PBMVC/REV.001/010410

    4

    CONSTRUCTIONAL FEATURES

    ConductorWe can offer cables with both copper or aluminium conductors. Conductors upto 1000 sq mm will be circular compacted & stranded and shall comply with IEC-60228 Class 2.

    Conductor screenThis will be an extruded layer of semiconducting XLPE applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen.

    InsulationThis will be an extruded layer of insulating grade XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen.

    Insulation screenThis will be a layer of semiconducting XLPE which will be applied by tripe extrusion process over the insulation.

    Metallic screenIt will consist of a layer of copper tape applied helically with overlap over insulation screen. Other combinations of metallic screens as per customers requirement can also be provided on request.

    Laying-upIn case of three core cables, the three cores are laid up with non hygroscopic fillers like polypropylene (PP) fillers at interstices and a binder tape is applied with an overlap. These binder tapes can be a PVC or Polyethylene, or Polypropylene or Polyester.

    Inner Sheath (Bedding)Extruded layer of PVC or PE is applied over the laid-up cores. PVC is normally of grade ST2 or PE of grade ST7 as per IEC 60502 Part 2.

    ArmourIn case of Armoured cables, the armour is applied over inner sheath. For Single core cables this is of aluminium wires and for multicore cables the armour can be of one among the following options:-a) Galvanized steel wire.b) Galvanized steel tape.c) Galvanised steel strip.The armour is applied helically over the bedding.

    Outer sheathAn extruded layer is applied over the armour in case of armoured cables and over the laid up cores in case of unarmoured cables. Outer sheath material can be either PVC of grade ST2 or PE of grade ST7 as per IEC-60502 Part 2.

    Special features which we can offer

    Watertightconstruction(bothradial&longitudinalforCu screen and Longitudinal for conductor)

    Strippableinsulationscreen

    TR-XLPEinsulation

    Metallicscreenofmultiplelayersofcoppertapesoracombination of copper wires and tapes to increase the earth fault current carrying capacity.

    Increasedarmourconductivitybywayofinsertionoftinned copper wires in armour.

    UVresistantcolouredoutersheath.

    LSF(LowSmoke&Fume)(LSOH/LSZH)MVcablesasper BS 7835, with LSF (LSOH/LSZH) inner/outer sheath.

    FlameRetardantMVcablesconfirmingtoIEC60332

    FR-PVCorFRRT-PVCorFRLS-PVCinnersheathand/or outer sheath

    Graphitecoatingonoutersheath.

  • OCI/PBMVC/REV.001/010410

    5

    OCI/PBMVC/REV.001/010410

    5

    PLANT AND MACHINERY

    Triple Head Extrusion - CCV Plant

    The medium voltage cable manufacturing facility at OCI is the most modern facility available in the region today with the state of the art machinery & equipment supplied by the biggest & the best names in the cable manufacturing machinery industry. The entire MV cables manufacturing plant at OCI is fully air-conditioned with humidity control to ensure contamination free atmosphere, the only kind in the whole of Middle East.

    The heart of the MV cables manufacturing facility is the CCV line. These lines are supplied by Maillefer, Finland incorporates some of the most modern features like,

    Triple extrusion head to ensure superior quality ofextrusion and uniform bonding of conductor screen, XLPE insulation & the insulation screen.

    InlineX-raymachineforcheckingproperconcentricityof all 3 layers of Insulation as well as measuring thickness of extruded materials, ovality and overall diameter.

    CDCC-CompletelyDryCuring&Coolinginaninertatmosphere of nitrogen.

    Fully Computerized auto-cure control system whichcontrols all driving parameters to achieve best curing of extruded materials.

    Fullyautomaticcompoundhandlingsystemensuringacontamination free line, which is absolutely essential to achieve a superior quality product.

    SOME OF THE OTHER MACHINES INCLUDE: CentralstrandingmachinefromSKETGermany

    CombinedCUtaping&Multiwirescreeningmachinefrom Pourtier France

    3000mmDrumtwisterLaying-upmachinefromSKETGermany

    3000 mm Drum twister Armouring machine fromPourtier France

    Combined 3000 mm Drum twister Laying-up &Armouring machine from Pourtier France

    SteeltapeArmouringmachinefromPourtierFrance

    Extrusion sheathing lines fromMaillefer Finland andfrom Troester Germany.

    With the manufacturing facilities incorporating the use of latest available technology, the MV cables offered by OCI provides customers with a definite advantage in terms of:

    Completeadherencetospecifications,

    Superioroverallperformance,

    Minimumriskofinsulationfailures,

    Muchlongerservicelife.

  • OCI/PBMVC/REV.001/010410

    6

    MV CABLES TESTING FACILITY

    Control Panel

    In Line X ray Unit

    OCI has made a major investment in the Testing facilities for its MV Cables factory. We have equipped ourselves with the latest and most advanced cable testing facility available in the world.

    All testing equipment such as Partial discharge detector, High Voltage Tester, Tan delta bridge and Impulse tester are supplied and erected by Hipotronics USA/Haefely & Tattex Switzerland.

    The screened room for Partial Discharge Test has been supplied & erected by M/s ETS Lindgren, UK, who are the world leaders in interference technology products. This facility is the first of its kind in the region & ensures detecting discharge levels less than 1pC.

    Apart from the above, the other major testing facilities include:

    a) Partial Discharge detector from M/s Hipotronics (Robinson) USA

    b) 1000 kVA/100 kV - Series Resonance Test set with fully automatic control system - from M/s Hipotronics, USA.

    c) 1500 kVA/120 kV - series Resonance test set with fully automatic control system from M/s Haefely Switzerland.

    d) 300 kV/15 kJ - Latest Impulse Test facility from M/s Haefely, Switzerland.

    e) Fully automatic Tan delta measuring facility from M/s Tettex, Switzerland.

    We have also installed many in line devices/facilities for checking the product quality during the manufacturing process like the X-Ray machine installed in the CCV line, Curing Optimization Software, online conductor resistance measurement device etc., to avoid any risk of failure & to ensure a long service life for our products.

    With these modern equipment & facilities, we ensure to maintain close manufacturing tolerances, high accuracies to customer specifications as well as effective monitoring of the entire manufacturing process to offer a world class product.

    OCIs quality management system is accredited to ISO 9001:2008 by TUV, Germany and BASEC, UK. The design validation for our MV Cables range has been done at recognized international laboratories.

    With the above state of the art Testing Facility, we can conduct all Routine Tests, Type Tests and Sample Tests mentioned in IEC 60502 part 2, BS 6622 & other international specifications, in-house. While 100% of the cables manufactured by OCI are tested for Routine tests prior to dispatch, however if the customers desire to witness these tests or other Type / Sample tests, they can nominate their representatives or appoint a third party to witness the same at OCI factory.

  • OCI/PBMVC/REV.001/010410

    7

    LIST OF TABLES

    SECTION CABLE TYPE CONDUCTOR TYPE TABLE PAGE NO.

    A SINGLE CORE UNARMOURED CABLES COPPER 1 To 5 8 To 12 ALUMINIUM 6 To 10 13 To 17

    B SINGLE CORE ALUMINIUM WIRE COPPER 1 To 5 18 To 22 ARMOURED CABLES ALUMINIUM 6 To 10 23 To 27

    C THREE CORE UNARMOURED CABLES COPPER 1 To 5 28 To 32 ALUMINIUM 6 To 10 33 To 37

    D THREE CORE STEEL WIRE ARMOURED COPPER 1 To 5 38 To 42 CABLES ALUMINIUM 6 To 10 43 To 47

    E THREE CORE STEEL TAPE ARMOURED COPPER 1 To 5 48 To 52 CABLES ALUMINIUM 6 To 10 53 To 57

    F RATING FACTORS AND OTHER TECHNICAL DETAILS 1 TO 17 60 To 68

  • OCI/PBMVC/REV.001/010410

    8

    COPP

    ER C

    ONDU

    CTOR

    SINGL

    E COR

    E, 2X

    CY, U

    narm

    oure

    d Ca

    bles,

    3.6/

    6 kV

    to IE

    C 60

    502-

    2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    225

    3550

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    5.9

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    218

    303

    408

    591

    821

    1035

    1277

    1601

    2105

    2640

    3383

    4272

    5618

    7286

    9046

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm2.

    52.

    52.

    52.

    52.

    52.

    52.

    52.

    52.

    62.

    83.

    03.

    23.

    23.

    23.

    24.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    81.

    81.

    81.

    81.

    81.

    92.

    02.

    12.

    22.

    32.

    42.

    65.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    431.

    431.

    431.

    431.

    431.

    521.

    601.

    691.

    771.

    861.

    942.

    116.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm17

    .518

    .520

    .021

    .523

    .024

    .526

    .027

    .530

    .533

    .537

    .041

    .044

    .550

    .054

    .57.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m51

    062

    075

    097

    512

    4514

    9017

    6521

    3027

    1533

    4042

    3552

    5066

    5083

    9510

    365

    8.0

    Stand

    ard

    drum

    leng

    th (

    5% To

    leran

    ce)

    m10

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0050

    050

    050

    050

    09.

    0M

    inimu

    m be

    nding

    radiu

    s of c

    able

    (Dur

    ing in

    stalla

    tion)

    mm35

    037

    040

    043

    046

    049

    052

    055

    061

    067

    074

    082

    089

    010

    0010

    90(B

    )Ele

    ctrica

    l Par

    amete

    rs1.

    0DC

    resis

    tance

    of c

    ondu

    ctor a

    t 20

    C (M

    axim

    um)

    ohm/

    km

    0.72

    70.

    524

    0.38

    70.

    268

    0.19

    30.

    153

    0.12

    40.

    0991

    0.07

    540.

    0601

    0.04

    700.

    0366

    0.02

    830.

    0221

    0.01

    762.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    0.92

    70.

    668

    0.49

    40.

    342

    0.24

    70.

    196

    0.15

    90.

    128

    0.09

    80.

    079

    0.06

    30.

    051

    0.04

    20.

    035

    0.03

    03.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    132

    0.12

    60.

    121

    0.11

    10.

    105

    0.10

    10.

    099

    0.09

    40.

    092

    0.09

    10.

    089

    0.08

    80.

    084

    0.08

    40.

    082

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    0.

    936

    0.68

    00.

    509

    0.36

    00.

    268

    0.22

    00.

    187

    0.15

    90.

    134

    0.12

    10.

    109

    0.10

    20.

    094

    0.09

    10.

    087

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km1.

    621

    1.17

    80.

    882

    0.62

    40.

    464

    0.38

    10.

    324

    0.27

    50.

    232

    0.21

    00.

    189

    0.17

    70.

    163

    0.15

    80.

    151

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.26

    0.29

    0.32

    0.37

    0.42

    0.46

    0.50

    0.54

    0.59

    0.61

    0.64

    0.67

    0.75

    0.86

    0.94

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    3.6

    kV a

    nd f=

    50

    HzmA

    /m0.

    290.

    330.

    360.

    420.

    480.

    520.

    570.

    610.

    670.

    690.

    720.

    760.

    850.

    971.

    068.

    0Su

    staine

    d cu

    rrent

    ratin

    gs (W

    ith b

    oth e

    nd b

    ondin

    g):-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    &Th

    erma

    l res

    istivi

    ty of

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing =

    0.8

    m, l

    aid in

    trefo

    il for

    matio

    n.A

    140

    166

    196

    239

    285

    323

    361

    406

    469

    526

    590

    655

    731

    806

    873

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p. =

    20

    C

    and

    Ther

    mal r

    esist

    ivity

    of so

    il = 1

    .5 C

    m/W

    , dep

    th of

    laying

    = 0

    .8 m

    , laid

    in tr

    efoil f

    orma

    tion.

    A13

    215

    718

    622

    727

    130

    834

    338

    744

    750

    456

    463

    571

    278

    985

    9

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A16

    319

    823

    829

    636

    141

    747

    354

    364

    173

    584

    595

    610

    9512

    4113

    739.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    3.58

    5.01

    7.15

    10.0

    113

    .59

    17.1

    621

    .45

    26.4

    634

    .32

    42.9

    057

    .20

    71.5

    090

    .09

    114.

    4014

    3.00

    3.6/

    6 (7

    .2) k

    VSi

    ngle

    Cor

    e Co

    pper

    Con

    duct

    orXL

    PE In

    sula

    ted

    Una

    rmou

    red

    To IE

    C 60

    502-

    2(S

    uita

    ble

    for

    3.8/

    6.6

    kV E

    arth

    ed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 1

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s + o

    pen

    helix

    Cu

    tape

    or

    cop

    per t

    ape

    (The

    det

    ails

    give

    n in

    bel

    ow T

    able

    are

    for

    copp

    er ta

    pe sc

    reen

    ed c

    able

    s). F

    or c

    oppe

    r wire

    scre

    ened

    ca

    bles

    the

    deta

    ils c

    an b

    e gi

    ven

    on s

    peci

    fic re

    ques

    t.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Cop

    per C

    ondu

    ctor

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    9

    COPP

    ER C

    ONDU

    CTOR

    SINGL

    E COR

    E, 2X

    CY, U

    narm

    oure

    d Ca

    bles,

    6/10

    kV

    to IE

    C 60

    502-

    2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    225

    3550

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    5.9

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    218

    303

    408

    591

    821

    1035

    1277

    1601

    2105

    2640

    3383

    4272

    5618

    7286

    9046

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm3.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    44.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    81.

    81.

    81.

    81.

    92.

    02.

    02.

    12.

    22.

    32.

    52.

    65.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    431.

    431.

    431.

    431.

    521.

    601.

    601.

    691.

    771.

    862.

    032.

    116.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm19

    .520

    .522

    .023

    .525

    .026

    .528

    .030

    .032

    .534

    .538

    .041

    .045

    .050

    .554

    .57.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m57

    568

    582

    510

    5013

    2515

    8018

    5522

    4028

    2534

    2042

    8052

    7566

    8084

    4510

    400

    8.0

    Stand

    ard

    drum

    leng

    th (

    5% To

    leran

    ce)

    m10

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0050

    050

    050

    050

    09.

    0M

    inimu

    m be

    nding

    radiu

    s of c

    able

    (Dur

    ing in

    stalla

    tion)

    mm39

    041

    044

    047

    050

    053

    056

    060

    065

    069

    076

    082

    090

    010

    1010

    90(B

    )Ele

    ctrica

    l Par

    amete

    rs1.

    0DC

    resis

    tance

    of c

    ondu

    ctor a

    t 20

    C (M

    axim

    um)

    ohm/

    km

    0.72

    70.

    524

    0.38

    70.

    268

    0.19

    30.

    153

    0.12

    40.

    0991

    0.07

    540.

    0601

    0.04

    700.

    0366

    0.02

    830.

    0221

    0.01

    762.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    0.92

    70.

    668

    0.49

    40.

    342

    0.24

    70.

    196

    0.15

    90.

    128

    0.09

    80.

    079

    0.06

    30.

    051

    0.04

    20.

    035

    0.03

    03.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    139

    0.13

    20.

    127

    0.11

    70.

    110

    0.10

    60.

    103

    0.10

    00.

    096

    0.09

    30.

    090

    0.08

    80.

    085

    0.08

    40.

    082

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    0.

    937

    0.68

    10.

    510

    0.36

    10.

    270

    0.22

    30.

    189

    0.16

    20.

    137

    0.12

    20.

    110

    0.10

    20.

    095

    0.09

    10.

    087

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km1.

    623

    1.18

    00.

    883

    0.62

    50.

    468

    0.38

    60.

    327

    0.28

    10.

    237

    0.21

    10.

    191

    0.17

    70.

    165

    0.15

    80.

    151

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.21

    0.23

    0.25

    0.29

    0.32

    0.35

    0.38

    0.42

    0.47

    0.51

    0.57

    0.63

    0.71

    0.81

    0.89

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    6 kV

    and

    f= 5

    0 Hz

    mA/m

    0.40

    0.43

    0.47

    0.55

    0.60

    0.66

    0.72

    0.79

    0.89

    0.96

    1.07

    1.19

    1.34

    1.53

    1.68

    8.0

    Susta

    ined

    curre

    nt ra

    tings

    (With

    both

    end

    bon

    ding)

    :-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    &Th

    erma

    l res

    istivi

    ty of

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing =

    0.8

    m, l

    aid in

    trefo

    il for

    matio

    n.A

    140

    166

    196

    239

    285

    323

    361

    406

    469

    526

    590

    655

    731

    806

    873

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p. =

    20

    C

    and

    Ther

    mal r

    esist

    ivity

    of so

    il = 1

    .5 C

    m/W

    , de

    pth o

    f layin

    g =

    0.8

    m, la

    id in

    trefoi

    l form

    ation

    .A

    132

    157

    186

    227

    271

    308

    343

    387

    447

    504

    564

    635

    712

    789

    859

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A16

    319

    823

    829

    636

    141

    747

    354

    364

    173

    584

    595

    610

    9512

    4113

    739.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    3.58

    5.01

    7.15

    10.0

    113

    .59

    17.1

    621

    .45

    26.4

    634

    .32

    42.9

    057

    .20

    71.5

    090

    .09

    114.

    4014

    3.00

    6/10

    (12)

    kV

    Sing

    le C

    ore

    Copp

    er C

    ondu

    ctor

    XLPE

    Insu

    late

    d U

    narm

    oure

    dTo

    IEC

    6050

    2-2

    (Sui

    tabl

    e fo

    r 6.

    35/1

    1kV

    Eart

    hed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 2

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s + o

    pen

    helix

    Cu

    tape

    or

    cop

    per t

    ape

    (The

    det

    ails

    give

    n in

    bel

    ow T

    able

    are

    for

    copp

    er ta

    pe sc

    reen

    ed c

    able

    s). F

    or c

    oppe

    r wire

    scre

    ened

    ca

    bles

    the

    deta

    ils c

    an b

    e gi

    ven

    on s

    peci

    fic re

    ques

    t.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Cop

    per C

    ondu

    ctor

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    10

    COPP

    ER C

    ONDU

    CTOR

    SINGL

    E COR

    E, 2X

    CY, U

    narm

    oure

    d Ca

    bles,

    8.7/

    15 k

    V to

    IEC

    6050

    2-2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    225

    3550

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    5.9

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    218

    303

    408

    591

    821

    1035

    1277

    1601

    2105

    2640

    3383

    4272

    5618

    7286

    9046

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm4.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    81.

    81.

    91.

    92.

    02.

    02.

    12.

    22.

    32.

    42.

    52.

    75.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    431.

    431.

    521.

    521.

    601.

    601.

    691.

    771.

    861.

    942.

    032.

    206.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm22

    .023

    .024

    .025

    .527

    .529

    .030

    .532

    .534

    .537

    .040

    .543

    .547

    .552

    .557

    .07.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m65

    577

    091

    011

    4014

    2016

    9519

    7523

    6529

    4535

    6544

    4054

    4568

    6586

    2510

    620

    8.0

    Stand

    ard

    drum

    leng

    th (

    5% To

    leran

    ce)

    m10

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0050

    050

    050

    050

    050

    09.

    0M

    inimu

    m be

    nding

    radiu

    s of c

    able

    (Dur

    ing in

    stalla

    tion)

    mm44

    046

    048

    051

    055

    058

    061

    065

    069

    074

    081

    087

    095

    010

    5011

    40(B

    )Ele

    ctrica

    l Par

    amete

    rs1.

    0DC

    resis

    tance

    of c

    ondu

    ctor a

    t 20

    C (M

    axim

    um)

    ohm/

    km

    0.72

    70.

    524

    0.38

    70.

    268

    0.19

    30.

    153

    0.12

    40.

    0991

    0.07

    540.

    0601

    0.04

    700.

    0366

    0.02

    830.

    0221

    0.01

    762.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    0.92

    70.

    668

    0.49

    40.

    342

    0.24

    70.

    196

    0.15

    90.

    128

    0.09

    80.

    079

    0.06

    30.

    051

    0.04

    10.

    035

    0.03

    03.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    146

    0.13

    90.

    132

    0.12

    20.

    116

    0.11

    20.

    109

    0.10

    50.

    100

    0.09

    70.

    094

    0.09

    10.

    089

    0.08

    70.

    085

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    0.

    938

    0.68

    20.

    511

    0.36

    30.

    273

    0.22

    60.

    193

    0.16

    60.

    140

    0.12

    50.

    113

    0.10

    40.

    098

    0.09

    40.

    090

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km1.

    625

    1.18

    10.

    885

    0.62

    90.

    473

    0.39

    10.

    334

    0.28

    80.

    242

    0.21

    70.

    196

    0.18

    00.

    170

    0.16

    30.

    156

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.17

    0.19

    0.21

    0.23

    0.26

    0.28

    0.30

    0.33

    0.37

    0.40

    0.45

    0.49

    0.55

    0.63

    0.69

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    8.7

    kV a

    nd f=

    50

    HzmA

    /m0.

    460.

    520.

    570.

    630.

    710.

    770.

    820.

    901.

    011.

    091.

    231.

    341.

    501.

    721.

    898.

    0Su

    staine

    d cu

    rrent

    ratin

    gs (W

    ith b

    oth e

    nd b

    ondin

    g):-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    lre

    sistiv

    ity o

    f soil

    = 1

    .5 C

    m/W

    , dep

    th of

    laying

    = 0

    .8 m

    , laid

    in tr

    efoil f

    orma

    tion.

    A14

    016

    619

    623

    928

    532

    336

    140

    646

    952

    659

    065

    573

    180

    687

    3

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p.=

    20 C

    and

    Ther

    mal r

    esist

    ivity

    of so

    il = 1

    .5 C

    m/W

    ,de

    pth o

    f layin

    g =

    0.8

    m, la

    id in

    trefoi

    l form

    ation

    .A

    132

    157

    186

    227

    271

    308

    343

    387

    447

    504

    564

    635

    712

    789

    859

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A16

    319

    823

    829

    636

    141

    747

    354

    364

    173

    584

    595

    610

    9512

    4113

    739.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    3.58

    5.01

    7.15

    10.0

    113

    .59

    17.1

    621

    .45

    26.4

    634

    .32

    42.9

    057

    .20

    71.5

    090

    .09

    114.

    4014

    3.00

    8.7/

    15 (1

    7.5)

    kV

    Sing

    le C

    ore

    Copp

    er C

    ondu

    ctor

    XLPE

    Insu

    late

    d U

    narm

    oure

    dTo

    IEC

    6050

    2-2

    (Sui

    tabl

    e fo

    r 8.

    7/15

    kV

    Eart

    hed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 3

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s + o

    pen

    helix

    Cu

    tape

    or

    cop

    per t

    ape

    (The

    det

    ails

    give

    n in

    bel

    ow T

    able

    are

    for

    copp

    er ta

    pe sc

    reen

    ed c

    able

    s). F

    or c

    oppe

    r wire

    scre

    ened

    ca

    bles

    the

    deta

    ils c

    an b

    e gi

    ven

    on s

    peci

    fic re

    ques

    t.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Cop

    per C

    ondu

    ctor

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    11

    COPP

    ER C

    ONDU

    CTOR

    SINGL

    E COR

    E, 2X

    CY, U

    narm

    oure

    d Ca

    bles,

    12/2

    0 kV

    to IE

    C 60

    502-

    2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    235

    5070

    9512

    015

    018

    524

    030

    040

    050

    063

    080

    010

    00

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    303

    408

    591

    821

    1035

    1277

    1601

    2105

    2640

    3383

    4272

    5618

    7286

    9046

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm5.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    55.

    54.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    91.

    92.

    02.

    02.

    12.

    22.

    32.

    42.

    52.

    62.

    75.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    521.

    521.

    601.

    601.

    691.

    771.

    861.

    942.

    032.

    112.

    206.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm25

    .026

    .028

    .029

    .531

    .032

    .534

    .537

    .039

    .543

    .046

    .050

    .055

    .059

    .57.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m86

    010

    0512

    4015

    4018

    0021

    0524

    8530

    9037

    1546

    0556

    2570

    5588

    4010

    820

    8.0

    Stand

    ard

    drum

    leng

    th (

    5% To

    leran

    ce)

    m10

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0050

    050

    050

    050

    050

    050

    09.

    0M

    inimu

    m be

    nding

    radiu

    s of c

    able

    (Dur

    ing in

    stalla

    tion)

    mm50

    052

    056

    059

    062

    065

    069

    074

    079

    086

    092

    010

    0011

    0011

    90(B

    )Ele

    ctrica

    l Par

    amete

    rs1.

    0DC

    resis

    tance

    of c

    ondu

    ctor a

    t 20

    C (M

    axim

    um)

    ohm/

    km

    0.52

    40.

    387

    0.26

    80.

    193

    0.15

    30.

    124

    0.09

    910.

    0754

    0.06

    010.

    0470

    0.03

    660.

    0283

    0.02

    210.

    0176

    2.0

    AC re

    sistan

    ce o

    f con

    ducto

    r at 9

    0 C

    (Ap

    prox

    imate

    )oh

    m/km

    0.

    668

    0.49

    40.

    342

    0.24

    70.

    196

    0.15

    90.

    128

    0.09

    80.

    079

    0.06

    30.

    051

    0.04

    10.

    034

    0.03

    03.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    145

    0.13

    70.

    128

    0.12

    10.

    116

    0.11

    30.

    109

    0.10

    40.

    101

    0.09

    80.

    095

    0.09

    20.

    090

    0.08

    84.

    0Im

    peda

    nce

    at 50

    Hz

    (App

    roxim

    ate)

    ohm/

    km

    0.68

    40.

    513

    0.36

    50.

    275

    0.22

    80.

    195

    0.16

    80.

    143

    0.12

    80.

    117

    0.10

    80.

    101

    0.09

    60.

    093

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km1.

    185

    0.88

    90.

    632

    0.47

    60.

    395

    0.33

    80.

    291

    0.24

    80.

    222

    0.20

    30.

    187

    0.17

    50.

    166

    0.16

    16.

    0Ca

    pacit

    ance

    at 5

    0 Hz

    (App

    roxim

    ate)

    mF/k

    m0.

    160.

    180.

    200.

    220.

    240.

    260.

    280.

    310.

    340.

    380.

    420.

    460.

    530.

    587.

    0Ap

    prox

    imate

    char

    ging

    curre

    nt pe

    r pha

    se a

    t Uo

    = 12

    kV a

    nd f=

    50

    HzmA

    /m0.

    600.

    680.

    750.

    830.

    900.

    981.

    061.

    171.

    281.

    431.

    581.

    732.

    002.

    198.

    0Su

    staine

    d cu

    rrent

    ratin

    gs (W

    ith b

    oth e

    nd b

    ondin

    g):-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    lre

    sistiv

    ity o

    f soil

    = 1

    .5 C

    m/W

    , dep

    th of

    laying

    = 0.

    8 m,

    laid

    in tre

    foil fo

    rmati

    on.

    A16

    619

    623

    928

    532

    336

    140

    646

    952

    659

    065

    573

    180

    687

    3

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p.=

    20 C

    and

    Ther

    mal r

    esist

    ivity

    of so

    il = 1

    .5 C

    m/W

    ,de

    pth o

    f layin

    g =

    0.8

    m, la

    id in

    trefoi

    l form

    ation

    .A

    157

    186

    227

    271

    308

    343

    387

    447

    504

    564

    635

    712

    789

    859

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A19

    823

    829

    636

    141

    747

    354

    364

    173

    584

    595

    610

    9512

    4113

    739.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    5.01

    7.15

    10.0

    113

    .59

    17.1

    621

    .45

    26.4

    634

    .32

    42.9

    057

    .20

    71.5

    090

    .09

    114.

    4014

    3.00

    12/2

    0 (2

    4) k

    VSi

    ngle

    Cor

    e Co

    pper

    Con

    duct

    orXL

    PE In

    sula

    ted

    Una

    rmou

    red

    To IE

    C 60

    502-

    2(S

    uita

    ble

    for

    12.7

    /22

    kV E

    arth

    edSy

    stem

    )

    SECT

    ION

    A -

    TABL

    E 4

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s + o

    pen

    helix

    Cu

    tape

    or

    cop

    per t

    ape

    (The

    det

    ails

    give

    n in

    bel

    ow T

    able

    are

    for

    copp

    er ta

    pe sc

    reen

    ed c

    able

    s). F

    or c

    oppe

    r wire

    scre

    ened

    ca

    bles

    the

    deta

    ils c

    an b

    e gi

    ven

    on s

    peci

    fic re

    ques

    t.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Cop

    per C

    ondu

    ctor

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    12

    COPP

    ER C

    ONDU

    CTOR

    SINGL

    E COR

    E, 2X

    CY, U

    narm

    oure

    d Ca

    bles,

    18/3

    0 kV

    to IE

    C 60

    502-

    2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    250

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    408

    591

    821

    1035

    1277

    1601

    2105

    2640

    3383

    4272

    5618

    7286

    9046

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm8.

    08.

    08.

    08.

    08.

    08.

    08.

    08.

    08.

    08.

    08.

    08.

    08.

    04.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    92.

    02.

    12.

    12.

    12.

    22.

    32.

    32.

    52.

    52.

    72.

    82.

    95.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    521.

    601.

    691.

    691.

    691.

    771.

    861.

    862.

    032.

    032.

    202.

    282.

    376.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm31

    .533

    .535

    .537

    .038

    .040

    .042

    .545

    .048

    .551

    .555

    .560

    .565

    .07.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m12

    6515

    3018

    4521

    2024

    2028

    3534

    6040

    9050

    2560

    5075

    4093

    6511

    385

    8.0

    Stand

    ard

    drum

    leng

    th (

    5% To

    leran

    ce)

    m10

    0010

    0010

    0010

    0010

    0050

    050

    050

    050

    050

    050

    050

    050

    09.

    0M

    inimu

    m be

    nding

    radiu

    s of c

    able

    (Dur

    ing in

    stalla

    tion)

    mm63

    067

    071

    074

    076

    080

    085

    090

    097

    010

    3011

    1012

    1013

    00(B

    )Ele

    ctrica

    l Par

    amete

    rs1.

    0DC

    resis

    tance

    of c

    ondu

    ctor a

    t 20

    C (M

    axim

    um)

    ohm/

    km

    0.38

    70.

    268

    0.19

    30.

    153

    0.12

    40.

    0991

    0.07

    540.

    0601

    0.04

    700.

    0366

    0.02

    830.

    0221

    0.01

    762.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    0.49

    40.

    342

    0.24

    70.

    196

    0.15

    90.

    127

    0.09

    80.

    079

    0.06

    30.

    050

    0.04

    10.

    034

    0.02

    93.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    149

    0.13

    90.

    132

    0.12

    70.

    123

    0.11

    80.

    113

    0.10

    90.

    106

    0.10

    20.

    098

    0.09

    60.

    093

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    0.

    516

    0.36

    90.

    280

    0.23

    40.

    201

    0.17

    30.

    150

    0.13

    50.

    123

    0.11

    40.

    106

    0.10

    20.

    097

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km0.

    894

    0.63

    90.

    485

    0.40

    50.

    348

    0.30

    00.

    260

    0.23

    40.

    213

    0.19

    70.

    184

    0.17

    70.

    168

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.14

    0.15

    0.17

    0.18

    0.20

    0.21

    0.23

    0.25

    0.28

    0.30

    0.34

    0.38

    0.42

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    18 kV

    and

    f= 5

    0 Hz

    mA/m

    0.79

    0.85

    0.96

    1.02

    1.13

    1.19

    1.30

    1.41

    1.58

    1.70

    1.92

    2.15

    2.38

    8.0

    Susta

    ined

    curre

    nt ra

    tings

    (With

    both

    end

    bon

    ding)

    :-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    l res

    istivi

    ty of

    soil

    = 1.

    5 C

    m/W

    , dep

    th of

    laying

    = 0

    .8 m

    , laid

    in tr

    efoil f

    orma

    tion.

    A19

    623

    928

    532

    336

    140

    646

    952

    659

    065

    573

    180

    687

    3

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p. =

    20 C

    and

    Ther

    mal

    resis

    tivity

    of s

    oil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing=

    0.8

    m, la

    id in

    trefoi

    l form

    ation

    .A

    186

    227

    271

    308

    343

    387

    447

    504

    564

    635

    712

    789

    859

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A23

    829

    636

    141

    747

    354

    364

    173

    584

    595

    610

    9512

    4113

    739.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    7.15

    10.0

    113

    .59

    17.1

    621

    .45

    26.4

    634

    .32

    42.9

    057

    .20

    71.5

    090

    .09

    114.

    4014

    3.00

    18/3

    0 (3

    6) k

    VSi

    ngle

    Cor

    e Co

    pper

    Con

    duct

    orXL

    PE In

    sula

    ted

    Una

    rmou

    red

    To IE

    C 60

    502-

    2(S

    uita

    ble

    for

    19/3

    3 kV

    Ear

    thed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 5

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s + o

    pen

    helix

    Cu

    tape

    or

    cop

    per t

    ape

    (The

    det

    ails

    give

    n in

    bel

    ow T

    able

    are

    for

    copp

    er ta

    pe sc

    reen

    ed c

    able

    s). F

    or c

    oppe

    r wire

    scre

    ened

    ca

    bles

    the

    deta

    ils c

    an b

    e gi

    ven

    on s

    peci

    fic re

    ques

    t.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Cop

    per C

    ondu

    ctor

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    13

    ALUM

    INIU

    M C

    ONDU

    CTOR

    SINGL

    E COR

    E, A2

    XCY,

    Unar

    mour

    ed C

    ables

    , 3.6

    /6 k

    V to

    IEC

    6050

    2-2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    225

    3550

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    5.9

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    6792

    125

    182

    251

    317

    390

    493

    646

    803

    1027

    1307

    1721

    2188

    2759

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm2.

    52.

    52.

    52.

    52.

    52.

    52.

    52.

    52.

    62.

    83.

    03.

    23.

    23.

    23.

    24.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    81.

    81.

    81.

    81.

    81.

    92.

    02.

    12.

    22.

    32.

    42.

    65.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    431.

    431.

    431.

    431.

    431.

    521.

    601.

    691.

    771.

    861.

    942.

    116.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm17

    .518

    .520

    .021

    .523

    .024

    .526

    .027

    .530

    .533

    .537

    .041

    .044

    .550

    .054

    .57.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m36

    041

    047

    056

    567

    577

    588

    010

    2012

    5515

    0518

    7522

    8528

    2534

    8042

    258.

    0Sta

    ndar

    d dr

    um le

    ngth

    (5%

    Toler

    ance

    )m

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    500

    500

    500

    500

    9.0

    Mini

    mum

    bend

    ing ra

    dius o

    f cab

    le (D

    uring

    insta

    llatio

    n)mm

    350

    370

    400

    430

    460

    490

    520

    550

    610

    670

    740

    820

    890

    1000

    1090

    (B)

    Electr

    ical P

    aram

    eters

    1.0

    DC re

    sistan

    ce o

    f con

    ducto

    r at 2

    0 C

    (Max

    imum

    )oh

    m/km

    1.

    200.

    868

    0.64

    10.

    443

    0.32

    00.

    253

    0.20

    60.

    164

    0.12

    50.

    100

    0.07

    780.

    0605

    0.04

    690.

    0367

    0.02

    912.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    1.53

    91.

    113

    0.82

    20.

    568

    0.41

    10.

    325

    0.26

    50.

    211

    0.16

    20.

    130

    0.10

    20.

    080

    0.06

    40.

    052

    0.04

    33.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    132

    0.12

    60.

    121

    0.11

    10.

    105

    0.10

    10.

    099

    0.09

    40.

    092

    0.09

    10.

    089

    0.08

    80.

    084

    0.08

    40.

    082

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    1.

    545

    1.12

    00.

    831

    0.57

    90.

    424

    0.34

    00.

    283

    0.23

    10.

    186

    0.15

    90.

    135

    0.11

    90.

    106

    0.09

    90.

    093

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km2.

    676

    1.94

    01.

    439

    1.00

    30.

    734

    0.58

    90.

    490

    0.40

    00.

    322

    0.27

    50.

    234

    0.20

    60.

    184

    0.17

    10.

    161

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.26

    0.29

    0.32

    0.37

    0.42

    0.46

    0.50

    0.54

    0.59

    0.61

    0.64

    0.67

    0.75

    0.86

    0.94

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    3.6

    kV a

    nd f=

    50

    HzmA

    /m0.

    290.

    330.

    360.

    420.

    480.

    520.

    570.

    610.

    670.

    690.

    720.

    760.

    850.

    971.

    068.

    0Su

    staine

    d cu

    rrent

    ratin

    gs (W

    ith b

    oth e

    nd b

    ondin

    g):-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    lre

    sistiv

    ity o

    f soil

    = 1

    .5 C

    m/W

    , dep

    th of

    laying

    = 0.

    8 m,

    laid

    in tre

    foil fo

    rmati

    on.

    A10

    812

    915

    218

    622

    125

    228

    131

    736

    741

    447

    052

    859

    967

    274

    3

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p.=

    20 C

    and

    Ther

    mal r

    esist

    ivity

    of so

    il = 1

    .5 C

    m/W

    ,de

    pth o

    f layin

    g =

    0.8

    m, la

    id in

    trefoi

    l form

    ation

    .A

    102

    122

    144

    176

    210

    240

    267

    303

    351

    397

    451

    512

    583

    658

    731

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A12

    715

    418

    423

    028

    032

    436

    842

    450

    257

    767

    377

    089

    610

    3311

    679.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    2.35

    3.29

    4.70

    6.58

    8.93

    11.2

    814

    .10

    17.3

    922

    .56

    28.2

    037

    .60

    47.0

    059

    .22

    75.2

    094

    .00

    3.6/

    6 (7

    .2) k

    VSi

    ngle

    Cor

    e Al

    umin

    ium

    Con

    duct

    orXL

    PE In

    sula

    ted

    Una

    rmou

    red

    To IE

    C 60

    502-

    2(S

    uita

    ble

    for

    3.8/

    6.6

    kV E

    arth

    edSy

    stem

    )

    SECT

    ION

    A -

    TABL

    E 6

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s +

    open

    hel

    ix C

    u ta

    pe

    or c

    oppe

    r ta

    pe (T

    he d

    etai

    ls gi

    ven

    in b

    elow

    Tab

    le a

    re fo

    r co

    pper

    tape

    scr

    eene

    d ca

    bles

    ). Fo

    r cop

    per w

    ire s

    cree

    ned

    cabl

    es th

    e de

    tails

    can

    be

    give

    n on

    spe

    cific

    requ

    est.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Alu

    min

    ium

    Con

    duct

    or

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    14

    ALUM

    INIU

    M C

    ONDU

    CTOR

    SINGL

    E COR

    E, A2

    XCY,

    Unar

    mour

    ed C

    ables

    , 6/1

    0 kV

    to IE

    C 60

    502-

    2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    225

    3550

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    5.9

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    6792

    125

    182

    251

    317

    390

    493

    646

    803

    1027

    1307

    1721

    2188

    2759

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm3.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    43.

    44.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    81.

    81.

    81.

    81.

    92.

    02.

    02.

    12.

    22.

    32.

    52.

    65.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    431.

    431.

    431.

    431.

    521.

    601.

    601.

    691.

    771.

    862.

    032.

    116.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm19

    .520

    .522

    .023

    .525

    .026

    .528

    .030

    .032

    .534

    .538

    .041

    .045

    .050

    .554

    .57.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m42

    547

    554

    064

    075

    586

    097

    011

    3013

    6515

    8019

    2523

    1028

    5535

    3542

    608.

    0Sta

    ndar

    d dr

    um le

    ngth

    (5%

    Toler

    ance

    )m

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    500

    500

    500

    500

    9.0

    Mini

    mum

    bend

    ing ra

    dius o

    f cab

    le (D

    uring

    insta

    llatio

    n)mm

    390

    410

    440

    470

    500

    530

    560

    600

    650

    690

    760

    820

    900

    1010

    1090

    (B)

    Electr

    ical P

    aram

    eters

    1.0

    DC re

    sistan

    ce o

    f con

    ducto

    r at 2

    0 C

    (Max

    imum

    )oh

    m/km

    1.

    200.

    868

    0.64

    10.

    443

    0.32

    00.

    253

    0.20

    60.

    164

    0.12

    50.

    100

    0.07

    780.

    0605

    0.04

    690.

    0367

    0.02

    912.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    1.53

    91.

    113

    0.82

    20.

    568

    0.41

    10.

    325

    0.26

    50.

    211

    0.16

    20.

    130

    0.10

    20.

    080

    0.06

    40.

    052

    0.04

    33.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    139

    0.13

    20.

    127

    0.11

    70.

    110

    0.10

    60.

    103

    0.10

    00.

    096

    0.09

    30.

    090

    0.08

    80.

    085

    0.08

    40.

    082

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    1.

    545

    1.12

    10.

    832

    0.58

    00.

    425

    0.34

    20.

    284

    0.23

    30.

    188

    0.16

    00.

    136

    0.11

    90.

    106

    0.09

    90.

    093

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km2.

    676

    1.94

    21.

    441

    1.00

    50.

    736

    0.59

    20.

    492

    0.40

    40.

    326

    0.27

    70.

    236

    0.20

    60.

    184

    0.17

    10.

    161

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.21

    0.23

    0.25

    0.29

    0.32

    0.35

    0.38

    0.42

    0.47

    0.51

    0.57

    0.63

    0.71

    0.81

    0.89

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    6 kV

    and

    f= 5

    0 Hz

    mA/m

    0.40

    0.43

    0.47

    0.55

    0.60

    0.66

    0.72

    0.79

    0.89

    0.96

    1.07

    1.19

    1.34

    1.53

    1.68

    8.0

    Susta

    ined

    curre

    nt ra

    tings

    (With

    both

    end

    bon

    ding)

    :-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    l res

    istivi

    tyof

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing =

    0.8

    m,

    laid

    in tre

    foil fo

    rmati

    on.

    A10

    812

    915

    218

    622

    125

    228

    131

    736

    741

    447

    052

    859

    967

    274

    3

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p. =

    20

    Can

    d Th

    erma

    l res

    istivi

    ty of

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing =

    0.8

    m, l

    aid in

    trefo

    il for

    matio

    n.A

    102

    122

    144

    176

    210

    240

    267

    303

    351

    397

    451

    512

    583

    658

    731

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A12

    715

    418

    423

    028

    032

    436

    842

    450

    257

    767

    377

    089

    610

    3311

    679.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    2.35

    3.29

    4.70

    6.58

    8.93

    11.2

    814

    .10

    17.3

    922

    .56

    28.2

    037

    .60

    47.0

    059

    .22

    75.2

    094

    .00

    6/10

    (12)

    kV

    Sing

    le C

    ore

    Alu

    min

    ium

    Con

    duct

    or

    XLPE

    Insu

    late

    d U

    narm

    oure

    d To

    IEC

    6050

    2-2

    (Sui

    tabl

    e fo

    r 6.

    35/1

    1 kV

    Ear

    thed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 7

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s +

    open

    hel

    ix C

    u ta

    pe

    or c

    oppe

    r ta

    pe (T

    he d

    etai

    ls gi

    ven

    in b

    elow

    Tab

    le a

    re fo

    r co

    pper

    tape

    scr

    eene

    d ca

    bles

    ). Fo

    r cop

    per w

    ire s

    cree

    ned

    cabl

    es th

    e de

    tails

    can

    be

    give

    n on

    spe

    cific

    requ

    est.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Alu

    min

    ium

    Con

    duct

    or

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    15

    ALUM

    INIU

    M C

    ONDU

    CTOR

    SINGL

    E COR

    E, A2

    XCY,

    Unar

    mour

    ed C

    ables

    , 8.7

    /15

    kV to

    IEC

    6050

    2-2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    225

    3550

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    800

    1000

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    5.9

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    6792

    125

    182

    251

    317

    390

    493

    646

    803

    1027

    1307

    1721

    2188

    2759

    3.0

    Insula

    tion

    thick

    ness

    (Nom

    inal)

    mm4.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    54.

    0O

    uter s

    heath

    thick

    ness

    (Nom

    inal)

    mm1.

    81.

    81.

    81.

    81.

    81.

    91.

    92.

    02.

    02.

    12.

    22.

    32.

    42.

    52.

    75.

    0O

    uter s

    heath

    thick

    ness

    (Mini

    mum)

    mm1.

    431.

    431.

    431.

    431.

    431.

    521.

    521.

    601.

    601.

    691.

    771.

    861.

    942.

    032.

    206.

    0Ca

    ble o

    vera

    ll diam

    eter (

    Appr

    oxim

    ate)

    mm22

    .023

    .024

    .025

    .527

    .529

    .030

    .532

    .534

    .537

    .040

    .543

    .547

    .552

    .557

    .07.

    0Ca

    ble w

    eight

    (App

    roxim

    ate)

    kg/k

    m50

    556

    062

    573

    085

    097

    510

    9012

    5514

    8517

    2520

    8524

    8030

    3537

    1544

    808.

    0Sta

    ndar

    d dr

    um le

    ngth

    (5%

    Toler

    ance

    )m

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    500

    500

    500

    500

    500

    9.0

    Mini

    mum

    bend

    ing ra

    dius o

    f cab

    le (D

    uring

    insta

    llatio

    n)mm

    440

    460

    480

    510

    550

    580

    610

    650

    690

    740

    810

    870

    950

    1050

    1140

    (B)

    Electr

    ical P

    aram

    eters

    1.0

    DC re

    sistan

    ce o

    f con

    ducto

    r at 2

    0 C

    (Max

    imum

    )oh

    m/km

    1.

    200.

    868

    0.64

    10.

    443

    0.32

    00.

    253

    0.20

    60.

    164

    0.12

    50.

    100

    0.07

    780.

    0605

    0.04

    690.

    0367

    0.02

    912.

    0AC

    resis

    tance

    of c

    ondu

    ctor a

    t 90

    C (

    Appr

    oxim

    ate)

    ohm/

    km

    1.53

    91.

    113

    0.82

    20.

    568

    0.41

    10.

    325

    0.26

    50.

    211

    0.16

    10.

    130

    0.10

    20.

    080

    0.06

    40.

    052

    0.04

    33.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    146

    0.13

    90.

    132

    0.12

    20.

    116

    0.11

    20.

    109

    0.10

    50.

    100

    0.09

    70.

    094

    0.09

    10.

    089

    0.08

    70.

    085

    4.0

    Impe

    danc

    e at

    50 H

    z (A

    ppro

    ximate

    )oh

    m/km

    1.

    546

    1.12

    20.

    833

    0.58

    10.

    427

    0.34

    40.

    287

    0.23

    60.

    190

    0.16

    20.

    139

    0.12

    10.

    110

    0.10

    10.

    095

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km2.

    678

    1.94

    31.

    443

    1.00

    60.

    740

    0.59

    60.

    497

    0.40

    90.

    329

    0.28

    10.

    241

    0.21

    00.

    191

    0.17

    50.

    165

    6.0

    Capa

    citan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )mF

    /km

    0.17

    0.19

    0.21

    0.23

    0.26

    0.28

    0.30

    0.33

    0.37

    0.40

    0.45

    0.49

    0.55

    0.63

    0.69

    7.0

    Appr

    oxim

    ate ch

    argin

    g cu

    rrent

    per p

    hase

    at U

    o =

    8.7

    kV a

    nd f=

    50

    HzmA

    /m0.

    460.

    520.

    570.

    630.

    710.

    770.

    820.

    901.

    011.

    091.

    231.

    341.

    501.

    721.

    898.

    0Su

    staine

    d cu

    rrent

    ratin

    gs (W

    ith b

    oth e

    nd b

    ondin

    g):-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    lre

    sistiv

    ity o

    f soil

    = 1

    .5 C

    m/W

    , dep

    th of

    laying

    = 0.

    8 m,

    laid

    in tre

    foil fo

    rmati

    on.

    A10

    812

    915

    218

    622

    125

    228

    131

    736

    741

    447

    052

    859

    967

    274

    3

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p. =

    20

    Can

    d Th

    erma

    l res

    istivi

    ty of

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing =

    0.8

    m, l

    aid in

    trefo

    il for

    matio

    n.A

    102

    122

    144

    176

    210

    240

    267

    303

    351

    397

    451

    512

    583

    658

    731

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A12

    715

    418

    423

    028

    032

    436

    842

    450

    257

    767

    377

    089

    610

    3311

    679.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    2.35

    3.29

    4.70

    6.58

    8.93

    11.2

    814

    .10

    17.3

    922

    .56

    28.2

    037

    .60

    47.0

    059

    .22

    75.2

    094

    .00

    8.7/

    15 (1

    7.5)

    kV

    Sing

    le C

    ore

    Alu

    min

    ium

    Con

    duct

    orXL

    PE In

    sula

    ted

    Una

    rmou

    red

    To IE

    C 60

    502-

    2(S

    uita

    ble

    for

    8.7/

    15 k

    V Ea

    rthe

    dSy

    stem

    )

    SECT

    ION

    A -

    TABL

    E 8

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s +

    open

    hel

    ix C

    u ta

    pe

    or c

    oppe

    r ta

    pe (T

    he d

    etai

    ls gi

    ven

    in b

    elow

    Tab

    le a

    re fo

    r co

    pper

    tape

    scr

    eene

    d ca

    bles

    ). Fo

    r cop

    per w

    ire s

    cree

    ned

    cabl

    es th

    e de

    tails

    can

    be

    give

    n on

    spe

    cific

    requ

    est.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Alu

    min

    ium

    Con

    duct

    or

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    16

    ALUM

    INIU

    M C

    ONDU

    CTOR

    SINGL

    E COR

    E, A2

    XCY,

    Unar

    mour

    ed C

    ables

    , 12/

    20 k

    V to

    IEC

    6050

    2-2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    235

    5070

    9512

    015

    018

    524

    030

    040

    050

    063

    080

    010

    00

    (A)

    Man

    ufac

    turing

    Dim

    ensio

    ns1.

    0Co

    nduc

    tor d

    iamete

    r (Ap

    prox

    imate

    )mm

    6.9

    8.1

    9.7

    11.4

    12.9

    14.3

    16.0

    18.4

    20.6

    23.3

    26.3

    30.0

    34.2

    38.2

    2.0

    Cond

    uctor

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    9212

    518

    225

    131

    739

    049

    364

    680

    310

    2713

    0717

    2121

    8827

    593.

    0Ins

    ulatio

    n thi

    ckne

    ss (N

    omina

    l)mm

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    5.5

    4.0

    Oute

    r she

    ath th

    ickne

    ss (N

    omina

    l)mm

    1.8

    1.8

    1.8

    1.9

    1.9

    2.0

    2.0

    2.1

    2.2

    2.3

    2.4

    2.5

    2.6

    2.7

    5.0

    Oute

    r she

    ath th

    ickne

    ss (M

    inimu

    m)mm

    1.43

    1.43

    1.43

    1.52

    1.52

    1.60

    1.60

    1.69

    1.77

    1.86

    1.94

    2.03

    2.11

    2.20

    6.0

    Cable

    ove

    rall d

    iamete

    r (Ap

    prox

    imate

    )mm

    25.0

    26.0

    28.0

    29.5

    31.0

    32.5

    34.5

    37.0

    39.5

    43.0

    46.0

    50.0

    55.0

    59.5

    7.0

    Cable

    weig

    ht (A

    ppro

    ximate

    )kg

    /km

    650

    720

    830

    970

    1085

    1215

    1375

    1630

    1880

    2250

    2660

    3230

    3925

    4680

    8.0

    Stand

    ard

    drum

    leng

    th (

    5% To

    leran

    ce)

    m10

    0010

    0010

    0010

    0010

    0010

    0010

    0010

    0050

    050

    050

    050

    050

    050

    09.

    0M

    inimu

    m be

    nding

    radiu

    s of c

    able

    (Dur

    ing in

    stalla

    tion)

    mm50

    052

    056

    059

    062

    065

    069

    074

    079

    086

    092

    010

    0011

    0011

    90(B

    )Ele

    ctrica

    l Par

    amete

    rs1.

    0DC

    resis

    tance

    of c

    ondu

    ctor a

    t 20

    C (M

    axim

    um)

    ohm/

    km

    0.86

    80.

    641

    0.44

    30.

    320

    0.25

    30.

    206

    0.16

    40.

    125

    0.10

    00.

    0778

    0.06

    050.

    0469

    0.03

    670.

    0291

    2.0

    AC re

    sistan

    ce o

    f con

    ducto

    r at 9

    0 C

    (Ap

    prox

    imate

    )oh

    m/km

    1.

    113

    0.82

    20.

    568

    0.41

    10.

    325

    0.26

    50.

    211

    0.16

    10.

    130

    0.10

    20.

    080

    0.06

    30.

    051

    0.04

    33.

    0Re

    actan

    ce a

    t 50

    Hz (A

    ppro

    ximate

    )oh

    m/km

    0.

    145

    0.13

    70.

    128

    0.12

    10.

    116

    0.11

    30.

    109

    0.10

    40.

    101

    0.09

    80.

    095

    0.09

    20.

    090

    0.08

    84.

    0Im

    peda

    nce

    at 50

    Hz

    (App

    roxim

    ate)

    ohm/

    km

    1.12

    20.

    833

    0.58

    20.

    428

    0.34

    50.

    288

    0.23

    70.

    192

    0.16

    50.

    141

    0.12

    40.

    112

    0.10

    30.

    098

    5.0

    Volta

    ge d

    rop

    (App

    roxim

    ate fo

    r 3 p

    hase

    syste

    m)v/

    amp/

    km1.

    943

    1.44

    31.

    008

    0.74

    10.

    598

    0.49

    90.

    410

    0.33

    30.

    286

    0.24

    40.

    215

    0.19

    40.

    178

    0.17

    06.

    0Ca

    pacit

    ance

    at 5

    0 Hz

    (App

    roxim

    ate)

    mF/k

    m0.

    160.

    180.

    200.

    220.

    240.

    260.

    280.

    310.

    340.

    380.

    420.

    460.

    530.

    587.

    0Ap

    prox

    imate

    char

    ging

    curre

    nt pe

    r pha

    se a

    t Uo

    = 12

    kV a

    nd f=

    50

    HzmA

    /m0.

    600.

    680.

    750.

    830.

    900.

    981.

    061.

    171.

    281.

    431.

    581.

    732.

    002.

    198.

    0Su

    staine

    d cu

    rrent

    ratin

    gs (W

    ith b

    oth e

    nd b

    ondin

    g):-

    8.1

    Laid

    direc

    t, gr

    ound

    temp

    . = 2

    0 C

    & Th

    erma

    l res

    istivi

    ty of

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing =

    0.8

    m, l

    aid in

    trefo

    il for

    matio

    n.A

    129

    152

    186

    221

    252

    281

    317

    367

    414

    470

    528

    599

    672

    743

    8.2

    Draw

    n int

    o ea

    rthen

    ware

    duc

    ts, g

    roun

    d tem

    p. =

    20

    C a

    ndTh

    erma

    l res

    istivi

    ty of

    soil =

    1.5

    C m

    /W, d

    epth

    of lay

    ing=

    0.8

    m, la

    id in

    trefoi

    l form

    ation

    .A

    122

    144

    176

    210

    240

    267

    303

    351

    397

    451

    512

    583

    658

    731

    8.3

    Laid

    in tre

    foil fo

    rmati

    on in

    air,

    amb

    ient te

    mp. =

    30

    C

    A15

    418

    423

    028

    032

    436

    842

    450

    257

    767

    377

    089

    610

    3311

    679.

    0Sh

    ort c

    ircuit

    curre

    nt ra

    ting

    of co

    nduc

    tor fo

    r 1 se

    cond

    kA

    3.29

    4.70

    6.58

    8.93

    11.2

    814

    .10

    17.3

    922

    .56

    28.2

    037

    .60

    47.0

    059

    .22

    75.2

    094

    .00

    12/2

    0 (2

    4) k

    VSi

    ngle

    Cor

    e A

    lum

    iniu

    m C

    ondu

    ctor

    XLPE

    Insu

    late

    d U

    narm

    oure

    dTo

    IEC

    6050

    2-2

    (Sui

    tabl

    e fo

    r 12

    .7/2

    2 kV

    Ear

    thed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 9

    Met

    allic

    Cop

    per S

    cree

    n(C

    oppe

    r scr

    een

    can

    be o

    f Cu

    wire

    s +

    open

    hel

    ix C

    u ta

    pe

    or c

    oppe

    r ta

    pe (T

    he d

    etai

    ls gi

    ven

    in b

    elow

    Tab

    le a

    re fo

    r co

    pper

    tape

    scr

    eene

    d ca

    bles

    ). Fo

    r cop

    per w

    ire s

    cree

    ned

    cabl

    es th

    e de

    tails

    can

    be

    give

    n on

    spe

    cific

    requ

    est.)

    XLPE

    Insu

    latio

    n

    Con

    duct

    or S

    cree

    n (S

    emi-c

    ondu

    ctiv

    e)

    Alu

    min

    ium

    Con

    duct

    or

    Insu

    latio

    n Sc

    reen

    (Sem

    i-con

    duct

    ive)

    Bind

    er T

    ape

    Out

    er S

    heat

    h

  • OCI/PBMVC/REV.001/010410

    17

    18/3

    0 (3

    6) k

    VSi

    ngle

    Cor

    e Al

    umin

    ium

    Con

    duct

    orXL

    PE In

    sula

    ted

    Una

    rmou

    red

    To IE

    C 60

    502-

    2(S

    uita

    ble

    for

    19/3

    3 kV

    Ear

    thed

    Syst

    em)

    SECT

    ION

    A -

    TABL

    E 10

    ALUM

    INIU

    M C

    ONDU

    CTOR

    SINGL

    E COR

    E, A2

    XCY,

    Unar

    mour

    ed C

    ables

    , 18/

    30 k

    V to

    IEC

    6050

    2-2

    Sr. N

    o.No

    mina

    l Are

    a of

    Con

    ducto

    rmm

    250

    7095

    120

    150

    185

    240

    300

    400

    500

    630

    8