Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product...

27
Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC [email protected]

Transcript of Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product...

Page 1: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Medical Device Risk Management

Strategies for Product LiabilityRita McIntyre, RN RAC

[email protected]

Page 2: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Overview

• Some Working Definitions

• Product Liability /Risk Management Alignment

• Overview of RM components

Page 3: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Business

Product liability

Regulatory

Risk to safety of patients, users, handlers

Areas of Risk

Page 4: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Definitions• Harm: physical injury/damage to the health of people

or to property and environment. • Hazard: potential source of harm• Risk: combination of the probability of occurrence of

harm and the severity of that harm• Minimal Risk: 21 CFR 50: the probability and

magnitude of harm or discomfort anticipated in the research are not greater in and of themselves than those ordinarily encountered in daily life or during routine physical or psychological exam or test.

• Risk management: systematic application of management policies, procedures and practices to the tasks of analyzing, evaluating and controlling risk.

Page 5: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Definitions

• Product liability: the liability of any or all parties along the chain of manufacture/distribution of any product for damage caused by the product:– Component manufacturers– Assembling manufacturer– Wholesaler– Distributor– Retail store owner (in OTC and non-medical

products)

Page 6: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Law systems

NegligenceStrict Liability

Misrepresentation

Tort Law

Express warrantyImplied Warranty (merchantability)Implied Warranty (fitness for use)

Contract Law

Civil LawSubstantive LawProcedural Law

Criminal Law

Constitutional Law

Page 7: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Why Is Product Liability a Serious Issue?

• They generate more $1-million plus verdicts than any other type of personal injury suits except malpractice.

• 29% of all verdicts are returned with judgments of $1 million or more.

• Defendants loose 56% of all cases which go to trial.

Page 8: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Basis of Liability Cases

• Product Defects– Design defects– Manufacturing defects– Warning defects

• Other Theories of liability include:– Negligence (focus in on the conduct of the manufacturer)– Strict Liability (even if the best care has been exercised)– Breach of Warranty (express or implied) (based on UCC)– Misrepresentation (may be considered the product defect)

Page 9: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Design

• Design defects as a theory of liability-“conscious” defects

• Defective in design: – Foreseeable risks– Could have been reduced or avoided– Omission of reasonable, alternative design – Risk analysis of alternate designs (clause 6.2)

• “The designer shall identify risk control measures that are appropriate for reducing risks to an acceptable level”.

Page 10: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Design

• Design Control Issues: Likely to favor plaintiffs– Easy to pick it apart and find some flaw– For IVD - need to prove misdiagnoses was result

of inherently imperfect sensitivity and specificity rather than a flaw in design controls

Page 11: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Risk vs. Benefit

• Risk/Benefit (Clause 6.5): – Risk Utility Test– Not reasonably safe if the foreseeable risks

of harm are sufficiently great in relation to the foreseeable therapeutic benefits

– Pharmaceutical implication: strict liability for design defects applies only if there is no therapeutic effect for any class of patient

Page 12: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Duty to Warn

• Duty to warn (labeling) (Clause 6.2): – Extends to all reasonably foreseeable risks of use

and misuse• May also extend to storage and handling/clean up of

spills and disposal of product. – Liability exists if you fail to warn or inadequately

warn– Covers warning of the specific risk and providing

instructions for use that describe how to avoid the risk or help otherwise mitigate the risk

• Guidance on information for safety covered in annex J of revised draft of standard.

Page 13: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Duty To Warn• Purpose of warning is to compel the

user to behave so as to avoid injury• What a plaintiff must prove

– Duty – None or inadequate warning– Injury occurred

• Adequacy of warning (conspicuousness, position on

label/insert, specificity of risk, intensity of language):– Noticeable– Comprehensible– Degree of intensity– Commensurate with risk– Undiluted/noticeable

Page 14: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Duty to Warn

• Product may be adequately designed and manufactured but will pose a risk in the absence of a warning or – risk communication.

• Duty may be defined as such: a reasonable person would want to be warned.

• MDR’s can be admissible and plaintiff's attorney can argue for admissibility. – Can be used to show that manufacturer knew of

certain risks and had a duty to warn.

Page 15: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Duty to Warn

• Manufacturer needs to be expert in the field (clause 3.3 Qualification of Personnel)

• Learned intermediary theory– Reasonably foreseeable uses of the product– Direct to consumer advertisement– Ultimately liable to the patient– If warning to the intermediary is inadequate or

misleading- liability remains

Page 16: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Duty to Warn

• Duty to warn (Clause 6.2):– Consciously disregarding a danger.– Remedies:

• Punitive damages:– If a manufacturer knew of defects or risks and failed to act

or concealed them

– Manufacturer must anticipate the environment in which a product will be used (thorough hazard analysis).

– Remote risks (assessing frequency).

Page 17: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Post Sale Duty to Warn• Post sale duty to warn (Clause 9 ).

– Those latent risks that become evident after distribution (closed loop risk management).

– Includes a duty to monitor changes in technology– Product complaints and post production risk

monitoring. • May not need to warn if a danger is obvious

or commonly known by the general public.• Manufacturer knew or should have known

about the risk.

Page 18: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Risk Communication(Annex J)

• Is the least preferred method of risk control.

• Allows users to proactively take measures to minimize exposure to residual or overall residual risk.

• Both content and format of communication needs to be taken into consideration.

Page 19: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Product Development Phases(MEDICAL DEVICES)

Product Risk Management- On-goingPrelim. Risk Assessment

Feasibility Design Pilot Base BusinessConcept

Page 20: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Cost of Change

$100 $1,000 $10,000

$100,000

$1,000,000

$0

$2 0 0 , 0 0 0

$4 0 0 , 0 0 0

$6 0 0 , 0 0 0

$8 0 0 , 0 0 0

$ 1, 0 0 0 , 0 0 0

$ 1, 2 0 0 , 0 0 0

1/1/1900 1/2 /19 00 1/3 /190 0 1/4 /19 00 1/5/190 0

Cos t o f Change $100 $1,000 $10 ,000 $10 0 ,000 $1,000 ,000

Concep t Feasab ility Dasign Pilo t Base Buisness

Page 21: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

ISO 14971 Process OverviewRisk Analysis

o determining user needs / intended useso hazard identificationo risk estimation

Risk Evaluationo risk acceptability decisions

Risk Controlo option analysiso implementationo residual risk evaluationo overall risk acceptance

Post Productiono post production experienceo review of risk management experience

Risk A

ssessment

Risk M

anagement

Page 22: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Critical Components ISO 14971• Management responsibility

– Risk acceptance policies/periodic reviews• Qualification of personnel

– Record of qualifications• Risk management plan

– Roadmap of RM (criteria for risk acceptance- before the analysis occurs)

• Risk management file– Where is the documentation

• Risk Evaluation– Risk acceptability decisions

• Risk Control– Risk reduction (eliminate, protect against, warn about)

Page 23: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Critical Components ISO 14971• Options analysis

– Inherent safety by design– Protective measures in the product or in the process– Safety information (warning)

• Risk/benefit analysis– If the risk is greater than would be generally acceptable, the

benefit must outweigh this risk-

• Overall residual risk– Combined impact of all risk for the product

• Risk Management Report– A summary of what was done- pointers to portions of the file– High level document/overview

• Post Production Information– Unanticipated risks– Under-anticipated risks

Page 24: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Risk Acceptance Policy

• Top Management shall document the policy for determining criteria for risk acceptability (Clause 3.2). – Stakeholder perception of acceptable risk– Comparison to similar devices– Acceptability may change over time

• Risk Management should be a part of the management review process.

• Go beyond the risk level approach.

Page 25: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

Rate vs. VolumeRate vs Volume of Events

4

15

11

14

24

40

23

2 23

20

5

10

15

20

25

30

35

40

45

Q1 2005 Q2 2005 Q3 2005 Q4 2005 Q1 2006 Q4 2007

Over Time

Tota

ls # Events

Rate

Page 26: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview

9 I N T O L E R -8 A B L E7

6 A R E G -5 L I O N4 A3 B R2 A PP

roba

bilit

y of

Occ

urre

nce

1 R1 2 3 4 5 6 7 8 9

Severity

IntolerableRegionAs Low AsReasonablyPracticableRegion(ALARP)BroadlyAcceptableRegion (BAR)

Risk Concept According to ISO 14971

April 2001 Tony C. Chan

Page 27: Medical Device Risk Management - ehcca.com · Medical Device Risk Management Strategies for Product Liability Rita McIntyre, RN RAC rmcintyr@ocdus.jnj.com. ... ISO 14971 Process Overview