EDITION 1/2014

MEDICAL CATALOGUE

Page 2: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

GCE wOrLDwIDE

Sales o�ce Sales representation Headquarters Production units Stock point

the GCe BusinessGCE has almost 100 years of experience in the manufacture and supp-ly of high pressure gas equipment. During this time the GCE product range has increased dramatically. Today´s product portfolio fits a large variety of applications, from simple pressure regulators and blowpipes for cutting and welding to highly sophisticated gas supply systems for the medical, electronic and analytical industries.

GCE GrOUp InCLUDEs fOUr bUsInEss ArEAs:•Cutting & Welding•Process Application•Medical•High Purity

OriGinsThe origins of GCE (Gas Control Equipment) go back to the start of the 20th century when Gas Welding was first invented. The GCE group was formed as an independent company in 1987 through the merging of two of the worlds leading gas and welding companies into one inde-pendent unit. GCE has grown rapidly since its establishment and is leading the restructuring of the European gas equipment industry through mergers and acquisitions. Through its extensive Research and Development programs GCE has set standards that have become the benchmark for the whole industry.

GCe serviCesThe main industrial customers for GCE are wholesalers and local distri-butors. However in some markets GCE distributes equipment with the full cooperation of the main gas supplier for that market.

For these companies GCE provides both commercial and technical support. A significant part of the sales volume in this area also comes from key end user accounts such as shipyards, repair shops, OEM custo-mers and welding machine manufacturers.

A COMPLete rAnGe FOr MeDiCALThe supply of Medical Gas Equipment is a very important part of our business. All Medical Gas Applications require the highest safety stan-dards, specialised knowledge and a full understanding of patient re-spiratory requirements. GCE fully complies with the European Medical Directive 93/42/EEG and the QSR (Quality System Regulations known as the GMP standards).Western Europe is the traditional market for a whole range of products for all different types of customers and together with the growing Eas-tern European market, these are GCE’s main sales area. Our sales force is also active in a number of other markets including North and South America, North Africa and the Middle East, and continues to expand to other parts of the world, such as China and India. As a result, our pro-ducts are designed in accordance with the requirements of all Europe-an standards as well as those of other regions where they will be used.Supplies to the major Gas Companies account for the majority of sales however in each market various distributors, healthcare providers, hos-pitals and other manufacturers of medical also play a significant role in the distribution of GCE-branded and CE-marked products.GCE supply complete systems for supplying oxygen, nitrous oxide, other gases and vacuum to hospitals, ambulance service providers, emergency services and home care providers, as well as other special services using this equipment.

Sales o�ce Sales representation Headquarters Production units Stock point

www.gcegroup.com

Page 3: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

COMBi vALves 3Combilite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

hiGh Pressure reGuLAtOrs 7MediSelect® II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8MediReg® II. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11MMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

hOsPitAL wArD equiPMent 17MediMeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Mediflow Ultra II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Accessories - MediWet II Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Vacuum Regulator - Medievac+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Accessories for Medievac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Suction Ejector - Medieject . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33MediCollect + Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Low Pressure Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Low Pressure Hoses - MediConnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Trolleys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Cylinder Holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

hOMeCAre 55ECOlite® 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Accessories for Gas Saver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Oxygen concentrator - NUVO LITE MARK 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Oxygen concentrator - NUVO 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60INOGEN ONE G2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61INOGEN ONE G3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

eMerGenCy equiPMent 65Demand Valves - EASE II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Bag Valve Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Masks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Ambulance Gas Panel II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Ambulance Regulators - MediReg® II with Electronic Signal Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Ambulance Regulators - Varimed with Electronic Signal Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76Gauge with Electrical Output Signal (same for MediReg® II and Varimed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78GSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Multistar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

hOsPitAL CentrAL GAs suPPLy systeM 81MM40 HP Unit Semiauto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82MM90 Automatic Gas Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84MM90 Semiautomatic Gas Manifold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85MM90 STANDBY Backup Medical Gas Manifold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Gas Manifold MC80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Gas Manifold MC25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Collection Pipe Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90High Pressure Hoses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Line Regulator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91MM40 Stabilizer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Stabilizer for Medical Oxygen, N2O and Air - MM7762 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Stabilizer for Medical Oxygen, N2O and Air - MC150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Simplex MMR Gas Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Medical Shut-off Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Non Return Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Emergency Shut-Off Valve Box DN15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98Emergency Shut-Off Valve Box DN20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99Pressure Watch with Gauge, Alarm and Quick Coupling DN15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100Pressure Watch with Gauge, Alarm and Quick Coupling DN20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101Pressure Monitor DN15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102Alarm C44 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103MC 7701 - Digital Pressure Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104Gas Alarm G4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105MediUnit - DIN type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106Gas Outlet MC70 (Terminal Unit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108Safety Valve Medical Pipeline Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109Pressure Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110Connecting Pipes for Cylinder Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111Cylinder Retaining Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111Connection Pipes for Cylinder Pack Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111Extension Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111Connecting Components for Cylinder Manifolds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112Non-return Valves for Connection Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112High Pressure Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112SIMPLEX - DUPLEX High Pressure valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112DUPLEX High Pressure valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112

GenerAL Business terMs AnD COnDitiOns 115

COnTEnTs

Page 4: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

2

Bucureşti

COnTACTs GCE rOMAnIA

contacts

contact

GCE Romania SRLStr. Alexandru Puşkin nr. 22Ap. 1, Cod 011996, Sector 1Bucureşti

tel + 40 21 316 76 72

Fax + 40 21 316 76 74

GCe rOMAniAEstablished in March 2002, GCE Romania is the GCE AB sales office on the Romanian market. Currently, the company is responsible for sales in Moldova and Turkey. The company team of four employees, is a professional, dynamic, flexible and prompt one. Along with well-known quali-ty products and services, it enhances the GCE position among the top companies in the Romanian industry.

COMbI VALVEs

Page 5: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

COMbI VALVEs

Page 6: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

4

CYLInDEr VALVE wITH InTEGrATED prEssUrErEGULATOr fOr UsE wITH MEDICAL GAsEs

MEDIVITAL® Made for life

15 yeArs LiFe tiMe • 15 year life time ensured by extended endurance and cycle testing for future market requirements • Slow opening shut off valve with new Patented design • Latest technology highest shock resistant gauge • Flow selector designed for optimal gas flow and patient safety • Guard design provides maximum protection for the valve

user FrienDLy • Suitable for use in Homecare, Emergency and Hospital applications • Easy read Flow Selector and Gauge • Shut off valve with clear open /closed status colour coded marking • Ergonomic guard design allows easy handling of the cylinder package by all users • Compact and lightweight design less than 1150 gr • Easy clean guard material

hiGhest sAFety • Testing in accordance with the following standards, ISO10524-3 ASTM G175 Pill test • ISO 10297 • CE marked CE 0434 in accordance with the Medical directive 93/42/EC and TPED 2010/35 EU • Phthalate and Halogenated polymer free components • MRI compatible up to Tesla 3 • For use with Oxygen, Nitrous Oxide and other Medical mixed gases up to 300 bar working pressure

userFrienDLy

Page 7: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

5

Pressure inDiCAtOr • Good visibility of values/status • Wide dial angle improving readability • 40 mm diameter • Fluorescent scale face

eAsy use FLOw seLeCtOr • Excellent view of all selected flows • Large clear 4,5 mm digits • Optimized ergonomics of hand wheel • Increased flow in between settings (min 50% of lower value) • Fixed arrow for flow indication on the front of the valve • Increased clearance around hose nipple, enables easy connnection/disconnection of cannula/mask • Facility for RF chip inside the flow control knob

bEnEfITs fOr EnD UsErsshut OFF vALve • Clear visibility of open/close status – colour indication • Good visibility of open/close direction • Space for RF chip inside the hand wheel

Pressure OutLet • Completely enclosed & protected by the guard • Open/close push system with wide plastic grips for easy operation, for all main types • Improved design for primary types

stAnDArD FeAtures

• Flow control unit • Flow outlet ports (fir tree or threaded) • Pressure outlet (quick coupler) • Active cylinder pressure indicator • Filling port with non-return valve • Shut-off valve • External pressure relief valve • Residual pressure valve • Excess flow device for small cylinder connections • Dust tube for big cylinder connections • Protective valve guard

Bed Hanger Humidifier Holder

fEATUrEs AnD ACCEssOrIEs

bEnEfITs fOr DIsTrIbUTOrsFiLLinG POrt • Complete enclosure of the filling port • Cover connected to the guard • Opening of cover only with a tool • Universal sealing for various designs of filling port

GuArD • Protects the complete valve (hose nipple, QC, SOV) • Integrated filling port cover • Easy cleaning • Ergonomic designed handle • Valving capability without guard removal • Fits to all types of cylinders up to max.package weight of 30 kg

new MArKinG (LAser) • On the valve rear • Easily visible through the guard

OPtiOnAL FeAtures

• Teflon taped cylinder connection • Electronic memory chip for easy traceability and cylinder control

ACCessOries

• Filling adaptor • Bed hanger • Humidifier holder • Customized electronic gauge option

Page 8: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

6

HIGH prEssUrE rEGULATOrs

teChniCAL DAtAGas: O2, AIR, N2O/O2 and other medical mixed gasesInlet pressure: Up to 300 bar (4500 psi)Outlet pressure: 3,6 to 5,5 bar - acc. to EN ISO 10524-3 (or per customer specification)RPV closing: >3 barPRV opening and re-closing: >5.5 barFlow ranges: 0-2, 0-6, 0-15 and 0-25 l/minMaterials: Metallic parts (gas wetted): brassElastomers: EPDM, silicon, PURPlastics: PA66, PEEK, PISprings (gas wetted): CuBe2, CuSn6Dimensions: Height: 153 mm; Width: 112 mm; Depth: 118 mmWeight:* 1150 gInlet stem: Tapered or parallel threads (17E, 25E, M18, per customer specification)Filling port: ISO 5145, NEVOC or per customer specificationRegulatory status: Complies with MDD 93/42/EEC Complies with TPED 99/36/EEC Complies with EN ISO 10524-3 Complies with ISO 10297 Complies with EN 1789 Complies with ASTM G175 Production in accordance with EN ISO 9001 and EN ISO 13485Classification: IIbManufacturer: GCE s.r.o, Žižkova 381, 583 81 Chotěboř

* Standard Combivalve (flow control unit 0-15 l/min, flow outlet, DIN quick coupling pressure outlet) with guard. All technical data are given for information only and are subject to modifications by the manufacturer.

Page 9: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

HIGH prEssUrE rEGULATOrs

Page 10: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

8

THE nEw GEnErATIOn Of MEDICAL HIGH prEssUrE GAs rEGULATOrs

HIGH prEssUrE rEGULATOr

MEDIsELECT® II

Rotating pressure gauge which allows convenient reading

Continuous flow between settings, in the unlikely event of mechanism failure

Two windows - frontal and lateral allow very good visibility of set values

360°

360°

360° swivelling outlet alows wider use of positioning

•Regulator with flow selector•Rotating pressure gauge which allows convenient reading•360° swivelling outlet – it enables better orientation of the nasal cannula or oxygen mask towards the patient

(preventing from twisting)• Innovative self centering flow setting device with continuous flow between settings. In the unlikely event of

indent mechanism failure, the patient will still be supplied with medical gas•Lateral and frontal reading of flow settings•Higher number of flow disc holes increases treatment options

Extra flow setting of 25 l/min on the traditional 15 l/min variant, allows use in resuscitation•The additional 7 l/min is intended for nebulization

Page 11: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

9

MEDIsELECT® II VArIAnTsBelow are examples of models. Please use the table below for you to find the appropriate regulator.

MeDiseLeCt® ii O2D - KL

• short connecting inlet stem left for use in suitcases, backpacks and bags

• 0-25 l/min

• slim, space-saving gauge

MEDIsELECT® II O2D - KL

MEDIsELECT® II O2D - KL

• short connecting bolts right for use in suitcases, backpacks and bags

• 0-25 l/min

• slim, space-saving gauge

• cylinder connections right, left attached flow selector

MEDIsELECT® II O2D - DQCKL

• as MEDISELECT DQCKR but with cylinder connection left and right flow selector

Art. Nr. Type Gas Flow range Inlet Outlet QC Inlet pressure Design* (l/min) connection connection (bar)

0720122 MEDISELECT® II O2 0-25 G3/4 9/16 - 200 D20720123 MEDISELECT® II O2 0-25 G3/4 9/16 DIN 200 D20720124 MEDISELECT® II O2 0-25 G3/4 9/16 - 200 D10720125 MEDISELECT® II O2 0-25 G3/4 9/16 DIN 200 D10720148 MEDISELECT® II O2 0-6 G3/4 9/16 - 200 D20720149 MEDISELECT® II O2 0-6 G3/4 9/16 - 200 D10720223 MEDISELECT® II O2 0-25 PIN INDEX 9/16 - 200 D20720261 MEDISELECT® II O2 0-6 PIN INDEX 9/16 - 200 D10720127 MEDISELECT® II CO2 0-25 W21,8×14 9/16 - 60 D10720133 MEDISELECT® II CO2 0-25 PIN INDEX 9/16 - 60 D10720138 MEDISELECT® II AIR 0-25 PIN INDEX 9/16 DIN 200 D2* pictures are showing ONLY orientation of the inlet connection (left or right)

Left - D2Right - D1

Page 12: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

10

MEDIsELECT® - TECHnICAL DATA

FLOw Curve FOr OxyGen (P2 = 4 BAr)

teChniCAL DAtAGas: O2, Air, N2O, CO2, N2O/O2

Inlet pressure range: Up to 300 barNominal outlet pressure: 4 barFlow ranges*: 0 to 2 l/min 0;0,1;0,2;0,3;0,4;0,5;0,6;0,7;0,8;1;1,5;2 0 to 6 l/min 0;0,25;0,5;0,75;1;1,5;2;2,5;3;4;5;6 0 to 25 l/min 0;1;2;3;4;5;6;7;9;12;15;25Inlet connection: According to national standardsOutlet connection: 9/16" UNF with hose nippleBody material: Nickel-plated brassControl knob: PolyamideO-rings: EPDMFilter: Sintered bronzeGauge cover: TPE (thermoplastic elastomer)Regulatory status: Complies with Medical Devices Directive 93/42/EEC Complies with EN ISO 10524-1 (Pressure regulators for use with medical gases) Complies with EN 1789 (Medical vehicles and their equipment - Road ambulances)Classification: Class IIbManufacturer: GCE, s.r.o, Žižkova 381 583 81 Chotebor, CZ

* Flowrates expressed at 23°C and 101,3 kPa

Oxygen

Flow Q [l/min]

Outlet pressure p2 [bar]

Page 13: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

11

Low weight

Ergonomic

Compact

Space saving gauge

360°

Rotating pressure gauge which allows convenient reading

THE nEw GEnErATIOn Of MEDICAL HIGH prEssUrE GAs rEGULATOrs

HIGH prEssUrE rEGULATOr

MEDIrEG® II

•Regulator with flow selector•Regulator with pressure outlet, constantly adjusted flow or with flowmeter•Rotating pressure gauge which allows convenient reading•Ergonomic and streamlined design•Easy cleaning surface•Compact and user friendly

Page 14: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

12

MEDIrEG® II VArIAnTsMEDIrEG 16 O2D - M

• with flowmeter tube, 0-16 l/min adjustable

MEDIrEG 4 O2D

• fixed set pressure regulator, 4 l/min

• outlet 3/8 with hose nipple

MEDIrEG 100 O2D - DQC

• fixed set pressure regulator

• outlet DIN quick coupler

MeDireG® iiArt. Nr. Type Gas Flowmeter Inlet Outlet QC Inlet pressure Design* connection connection (bar)0724114 MEDIREG® II O2 YES G3/4 9/16 - 200 D50724118 MEDIREG® II O2 - G3/4 DIN 200 D40724128 MEDIREG® II O2 - PIN INDEX DIN 200 D40724141 MEDIREG® II O2 - G3/4 G3/8 200 D4 0724142 MEDIREG® II O2 - G3/4 DIN 200 D40724204 MEDIREG® II, el. gauge 4-20mA O2 - G3/4 DIN 200 D30724206 MEDIREG® II, el. gauge 4-20mA O2 - PIN INDEX DIN 200 D30724126 MEDIREG® II N2O - G3/8 DIN 60 D40724131 MEDIREG® II N2O - PIN INDEX DIN 60 D40724132 MEDIREG® II CO2 - PIN INDEX DIN 60 D40724115 MEDIREG® II AIR YES G5/8 9/16 - 200 D50724121 MEDIREG® II AIR - G5/8 DIN 200 D40724130 MEDIREG® II AIR - PIN INDEX DIN 200 D40724207 MEDIREG® II, el. gauge 4-20mA AIR - G5/8 DN 200 D3* pictures are showing ONLY orientation of the inlet connection (left or right)

Left - D3 Right - D4 Right - D5

Page 15: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

13

MEDIrEG® II - TECHnICAL DATA

FLOw Curve FOr OxyGen (P2 = 4 BAr)

teChniCAL DAtAGas: O2, Air, N2O, CO2, N2O/O2

Inlet pressure range: Up to 300 barNominal outlet pressure: 4 barInlet connection: According to national standardsOutlet connection: M12×1,25, G3/8, G1/4 with hose nippleBody material: Nickel-plated brassControl knob: PolyamideO-rings: EPDMFilter: Sintered bronzeGauge cover: TPE (thermoplastic elastomer)Regulatory status: Complies with Medical Devices Directive 93/42/EEC Complies with EN ISO 10524-1 (Pressure regulators for use with medical gases) Complies with EN 1789 (Medical vehicles and their equipment - Road ambulances)Classification: Class IIbManufacturer: GCE, s.r.o, Žižkova 381 583 81 Chotebor, CZ

Oxygen

Flow Q [l/min]

Outlet pressure p2 [bar]

Page 16: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

14

HIGH prEssUrE rEGULATOr

MMr•MMR is a dual stage cylinder valve with automatic compensation for the gradual fall of pressure occuring in

a gas cylinder when the gas is used •An optimal field of application for the MMR is for the reserve gas cylinder that will be used, via the Pressure

Monitor and Pressure watch, if an interruption in the gas supply occurs•MMR has a very high flow capacity and gives the stable and even pressure necessary for certain medical gas

applications•The regulator is available for air and oxygen and has a preset working pressure•A safety valve protects the equipment from overpressure

Page 17: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

15

14

2

4

bar0

/ 16bar

0

400

/300

128

6

10100

200A

140

95

170

155

65

185

61

MMr - DUAL sTAGE rEGULATOr fOr MEDICAL UsE

Art. Nr. Description Inlet Outlet connection connection325396786 MMR for breathing oxygen, P2= 4,5 bar W 21.8 × 1/14” G 3/8325396787 MMR for breathing air, P2=5 bar G 5/8 G 3/8316638 MMR for I-air, P2=8 bar G 5/8 G 3/8

teChniCAL DAtAWeight: ca 2400 grCapacity: ca 30 m3/h at P1 = 200 bar (20 000 kPa) and at P2 = 5 bar (500kPa)Outlet: according to standard SS 8752430

sPAre PArtsArt. Nr. Description Gas9444550 Washer inlet stem O2/AIR 10 pcs

hOsesArt. Nr. Gas Length (m) Inlet connection Outlet QC SS 325197814 O2 1.3 G 3/8 - 6 mm Straight male 325197815 N2O 1.3 G 3/8 LH - 6 mm Straight male 325197816 AIR 1.3 G 3/8 - 8 mm Straight male 325197817 I-AIR 1.3 G 3/8 - 8 mm Straight male

Note! Measurements in mm.

Page 18: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

16

HOspITAL wArDEQUIpMEnT

Page 19: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

HOspITAL wArDEQUIpMEnT

Page 20: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

18

fLOw-METErInG DEVICE

MEDIMETEr•Medimeter is a flowmeter intended for control and measurement of flow of air or oxygen administered

to patients•Flat surface float allows easy and safe reading of flow values by the users•Ergonomic design, easy for cleaning•Available with probe connector, rail mounting with a hose and twin versions•Soft closing mechanism•Resistant float against impact•New scale - better reading of flow values

Page 21: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

19

easy to purified surface area

ergonomic design

Flow adjustment easy to read, see sketch (for example 11 l/min)

MEDIMETEr p O2 DIn 15

• Flowmeter with measuring tube, 0-16 l/min

• Inlet – quick coupler DIN

• Outlet 9/16 with hose nipple

MEDIMETEr r DIn 1,5 15 O2

• Flowmeter with measuring tube, 0-16 l/min

• with rail clamp and hose 1.5 m

• Inlet – hose down

MEDIMETEr p DIn 15 O2 DUO

• Double flowmeter with measuring tube, 0-16 l/min

• Inlet – quick coupler DIN

ADApTEr

• M12×1.25 female thread on 9/16" male thread

MEDIMETEr

Page 22: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

20

DIsTrIbUTOrDUOLInE p O2 Y, 2 × DInQC

• Distributor with inlet DIN connector, Outlet 2× DIN QC

DUOLInE r O2, 2 × DInQC

• Distributor with inlet DIN connector to 1.5 m hose, outlet 2× DIN QC, with rail clamp

DUOLInE p AIr Y, 2 × DInQC

• Y-connector with inlet DIN connector, Outlet 2× DIN QC

DUOLInE r O2, 2 × nfQC

• Distributor with NF inlet connector to 1.5 m hose, outlet 2× NFQC

• with rail clamp and hose

Page 23: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

21

Art. Nr. Description Din MeDiMeter „P“ (FLOwMeter with MeAsurinG tuBe) with PLuG0730120 MEDIMETER P DIN, 15 O2

0730163 MEDIMETER P DIN, 15 AIR0730166 MEDIMETER P DIN, 15 O2 Duo Y0730183 MEDIMETER P DIN, 15 AIR Duo Y

Din MeDiMeter „r“ with A neutrAL COLOr hOse 1,5 M BLACK0730164 MEDIMETER R DIN1,5; 15 O2 bl0730165 MEDIMETER R DIN1,5; 15 AIR bl0730167 MEDIMETER R DIN1,5; 15 O2 Duo Y bl0730184 MEDIMETER R DIN1,5; 15 AIR Duo Y bl

Din MeDiMeter „r“ with COLOr-CODeD hOse 1,5 M0730185 MEDIMETER R DIN1,5; 15 O2 wh0730186 MEDIMETER R DIN1,5; 15 AIR bl/wh0730187 MEDIMETER R DIN1,5 15 O2 Duo wh0720188 MEDIMETER R DIN1,5; 15 AIR Duo Y bl/wh

nF (AFnOr) MeDiMeter „P“ (FLOwMeter with MeAsurinG tuBe)388239438280 MEDIMETER P NF, 15 O2

388239438320 MEDIMETER P NF, 15 AIR388239438460 MEDIMETER P NF, 15 O2 Duo388239438450 MEDIMETER P NF, 15 AIR Duo

nF (AFnOr) MeDiMeter „r“ with A neutrAL COLOr hOse 1,5 M BLACK388239438290 MEDIMETER R NF1,5; 15 O2

388239438330 MEDIMETER R NF1,5; 15 AIR388239438440 MEDIMETER R NF1,5; 15 O2 Duo388239438430 MEDIMETER R NF1,5; 15 AIR Duo

MEDIMETEr

Art. Nr. Description DistriButiOn "P" with PLuG9409310 DUOLINE P O2 Y, 2× DINQC9588520 DUOLINE P AIR Y, 2× DINQC

DistriButOr "r" with A neutrAL COLOr hOse 1,5 M BLACK0727506 DUOLINE R 1,5 Y O2, 2× DINQC bl0727507 DUOLINE R 1,5 Y AIR, 2× DINQC, bl0727501 MULTISTAR O2, 4× DINQC

DistriButOr "r" with COLOr-CODeD hOse 1,5 M0727508 DUOLINE R 1,5 Y O2, 2× DINQC wh0727509 DUOLINE R 1,5 Y AIR, 2× DINQC, bl/whK007267 DUOLINE P O2 Y, 2× NFQCK007268 DUOLINE P AIR Y, 2× NFQC

DIsTrIbUTOrs (DIn AnD AfnOr)

Legend: MEDIMETER R NF1, 5 15 O2 Duo = eg: MEDIMETER (name), R (rail / rail version), P (sample/connector version), DIN/NF (standard), 1,5 (1,5 m hose length), 15 (Flow in l/min), O2 (gas), Duo (two outlets).

D9 D11D8 D12

Page 24: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

22

teChniCAL DAtA - MeDiFLOw uLtrA Ans MeDiMeter

MEDIMETErInlet pressure: 4,5 bar +/-10%Flow ranges: 0 to 16 l/min continuouslyInlet connections: country-and gas-type connectorOutlet connections: all DIN versions 9/16 "UNF with hose nipple, all NF (AFNOR) versions M12×1, 25 with hose nippleBody material: Nickel-plated brassStorage: -20° to 60° COperation: -30° to 60° CControl knob: PolyamidO-rings: EPDMFilter: Fabric filter V2A Regulatory status: Complies with medical devices directive 93/42/EE Complies with EN 15 002 (Flow - metering devices for connection to terminal units of medical gas pipeline systems)

sPAre PArts Art. Nr. Description

135

388239438400 - 1460 g - T=140

160

958820 - 360 g

115

115

388239406530 - 340 g

110

160

160

388239438420 - 790 g

120

1,5 m- 460 g

9437250 External tube (10 pcs)9454170 O-ring (20 pcs) 9451160 Hose nipple 9/16 UNF with o-ring (10 pcs)

rAiLs / rAiL terMinALs Art. Nr. Description

14090797 1 m standard rail DIN with 3 wall mount per meter Specify meter length when ordering 14090798 DIN rail terminal with drawer units universal 14090932 DIN rail terminal block with clamp for V2A Suction bottles326000970 Nordic rail clamp with clamp lock326001299 Nordic rail clamp with ball14090799 Equipment rack profile with screws for mounting on walls or equipment326000968 Hook for respiratory masks to rail clamp, U-shaped326000976 Suction hooks on rail clamp, straight325197111 Catheter tube holder for universal rail clamp

14090798 14090799

14090932

326000976

326000968

Page 25: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

23

Independence of the pressure fluctuation with inlet pressure range of 2,8 – 8 bar

Continuous flow between settings, in the unlikely event of mechanism failure

Two windows - frontal and lateral allow very good visibility of set values

360°

360° swivelling outlet alows wider use of positioning

MEDIfLOw® ULTrA II Is THE nEw GEnErATIOn Of MEDICAL fLOw sELECTOr DEVICE wITH bUILT-In rEGULATOr

• It covers a comprehensive combination of inlet and outlet connections and offers various options for all medical applications, from neonatal care through to resuscitation.

•Built-in regulator provides a very stable and precise flow, independent of the pressure in the medical central gas system or cylinder.

• Innovative self centering flow setting device with continuous flow between settings. In the unlikely event of indent mechanism failure, the patient will still be supplied by medicinal gas.

•Lateral and frontal reading of flow settings.•360° swivelling outlet – it enables better orientation of the nasal cannula or oxygen mask towards the patient

(preventing from twisting).• Higher number of flow disc holes increases treatment options. Extra flow setting of 25 l/min on the

traditional 15 l/min variant, allows use in resuscitation. The additional 7 l/min is intended for nebulization.•Ergonomic and streamlined design.

fLOw-METErInG DEVICE

MEDIfLOw® ULTrA II

Page 26: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

24

More security through aalso constant flow "between the different flow levels"

360° Flow outlet rotates 360 °

Flows from the front display and the side read

Innovative, self-centering handwheel for quick and precise flow adjustment

Precise flow discharge through integrated pressure regulator Inlet pressure fluctuations from 2.8 to 8 bar be compensated

Wall supply unit with flow regulator

Mobile emergency care for five patients

MEDIFLOW ULTRA und MEDIMETERals Versionen für DIN-Schiene

MEDIfLOw ULTrA AnD MEDIMETEr

MEDIfLOw® ULTrA r, nf, O2

• with rail clamp and hose 1.5 m = AFNOR NF connector • Hose outlet from the bottom of the rail terminal • Outlet to all threads, other than DIN variants M12×1, 25

Supply column with O2 and vacuum regulator MEDIMETER and MEDIFLOW ULTRA

Page 27: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

25

MEDIfLOw® ULTrAMEDIfLOw® ULTrA p DIn O2

• for O2, Flow 0-2 l/min for neonatal use, 0-6 l/min and 0-25 l/min available

• with DIN connector for direct insertion into the socket

• as Air 25 version

MEDIfLOw® ULTrA r O2

• O2

• for O2, Flow 0-2 l/min for neonatal use, 0-6 l/min and 0-25 l/min available

• with rail clamp and hose 1.5 m

• hose outlet from the bottom of the rail terminal

MEDIfLOw® ULTrA r DUO O2

• duo version with 2 flow controllers

• with rail clamp and hose 1.5 m

MEDIfLOw® ULTrA p DIn DUO O2

• with DIN connector for direct insertion into the socket

MULTIsTAr O2, 4× MfU

• 4-way flow regulator 0-25 l/min

• supply via a separate hose to DIN couple

• mounting plate can by straps (not included) to a gas bottle or a device to be attached

Page 28: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

26

Din FLOwMeter “P” with quiCK COuPLerArt. Nr. Description Gas Flow range0728109 MEDIFLOW® ULTRA II AIR 0 - 25 l/min 0728110 MEDIFLOW® ULTRA II O2 0 - 2 l/min 0728111 MEDIFLOW® ULTRA II O2 0 - 6 l/min 0728112 MEDIFLOW® ULTRA II O2 0 - 25 l/min 0728132 MEDIFLOW® ULTRA II O2 0 - 2 l/min 0728133 MEDIFLOW® ULTRA II O2 0 - 6 l/min 0728134 MEDIFLOW® ULTRA II O2 0 - 25 l/min 0728139 MEDIFLOW® ULTRA II AIR 0 - 25 l/min 0727030 MEDIFLOW® + p Medap O2 0 - 15 l/min 0727031 MEDIFLOW® + p Medap O2 0 - 15 l/min DUO

Din FLOwMeter "r" with A neutrAL COLOr hOse 1,5 M BLACK (BL) Art. Nr. Description Gas Flow range Hose 0728117 MEDIFLOW® ULTRA II AIR 0 - 25 l/min 1.5m bl 0728118 MEDIFLOW® ULTRA II O2 0 - 2 l/min 1.5m bl0728119 MEDIFLOW® ULTRA II O2 0 - 6 l/min 1.5m bl 0728120 MEDIFLOW® ULTRA II DUO Y O2 0 - 25 l/min 1.5m bl 0728127 MEDIFLOW® ULTRA II DUO Y O2 0 - 25 l/min 1.5m bl 0728140 MEDIFLOW® ULTRA II DUO Y AIR 0 - 25 l/min 1.5m bl 0727032 MEDIFLOW® + r Medap O2 0 - 15 l/min 1.5m bl 0728141 MULTISTAR O2 0 - 25 l/min 1.5m bl

Din FLOwMeter "r" with COLOr-CODeD hOse 1 5 MArt. Nr. Description Gas Flow range Hose 0728219 MEDIFLOW® ULTRA II AIR 0 - 25 l/min bl/wh 0728220 MEDIFLOW® ULTRA II O2 0 - 25 l/min wh 0728221 MEDIFLOW® ULTRA II DUO Y O2 0 - 25 l/min wh 0728222 MEDIFLOW® ULTRA II DUO Y AIR 0 - 25 l/min bl/wh 0727035 MEDIFLOW + r Medap DUO Y O2 0 - 15 l/min wh

FLOwMeter "P" (nF)AFnOr with PLuG Art. Nr. Description Gas Flow range0728115 MEDIFLOW® ULTRA II O2 0 - 25 l/min 0728116 MEDIFLOW® ULTRA II AIR 0 - 25 l/min 0728135 MEDIFLOW® ULTRA II DUO AIR 0 - 25 l/min 0728138 MEDIFLOW® ULTRA II DUO O2 0 - 25 l/min

FLOwMeter "r" with A neutrAL COLOr hOse 1,5 M BLACKArt. Nr. Description Gas Flow range Hose 0728121 MEDIFLOW® ULTRA II AIR 0 - 25 l/min 1.5m bl 0728124 MEDIFLOW® ULTRA II O2 0 - 25 l/min 1.5m bl 0728128 MEDIFLOW® ULTRA II DUO AIR 0 - 25 l/min 1.5m bl 0728131 MEDIFLOW® ULTRA II DUO O2 0 - 25 l/min 1.5m bl

MEDIfLOw® ULTrA

D1 D2

D10D7

D3

D4

Legend: MEDIMETER R NF1, 5 15 O2 Duo = eg: MEDIMETER (name), R (rail / rail version), P (sample/connector version), DIN/NF (standard), 1,5 (1,5 m hose length), 15 (Flow in l/min), O2 (gas), Duo (two outlets).

Page 29: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

27

teChniCAL DAtA - MeDiFLOw® uLtrAInlet pressure: 2,8-8,0 barOutlet pressure: max. 2,1 barFlow levels: 0 to 2 l/min 0 / 0,1 / 0,2 / 0,3 / 0,4 / 0,5/ 0,6 / 0,7 / 0,8 / 1 / 1,5 / 2,0 0 to 6 l/min 0 / 0,25 / 0,5 / 0,75 / 1 / 1,5/ 2 / 2,5 / 3 / 4 / 5 / 6 0 to 25 l/min 0 / 1 / 2 / 3 / 4 / 5/ 6 / 7 / 9 / 12 / 15 / 25Inlet connections: Countries and gas type-specificOutlet Connections: 9/16 "UNF with hose nipple NF (AFNOR versions M12×1.25)Body material: Nickel-plated brass Operating temperature: -20 °C to 60 °CStorage temperature: -30 °C to 60 °COuter plastic parts: PolyamideO-rings: EPDMFilter: Sintered bronze / fabric filter V2ARegulatorischer Status: met MDD 93/42/EEC, Class 2a, complies with ENReducer latex free: 10524-4, complies with EN 1789.2000

0727501- 1900 g - T=105

215

156

0 728 120 - 820 gB= 40

130

75

958820 - 360 g

115

115

Note! Measurements in mm.

Page 30: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

28

ACCEssOrIEs - MEDIwET II HUMIDIfIEr

The humidifier for oxygen therapy is a device allowing an increase in the relative humidity in the oxygen supplied to the patient.

Art. Nr. DescriptionK294402 Mediwet 134 ºC inlet connection 9/16 UNF F K294432 Mediwet 134 ºC inlet connection G 3/8 F

teChniCAL DAtAContents: Only sterile waterDimensions: Height 190 × Width 67 (incl hose nipple)× Ø 57 mmWeight: Polysulphone version 115 gCapacity: 200 ml of waterConsumption: 6 ml of water per hour at a gas flow of 10 l/min at 20 ºCMaterial: Jar autoclavable at 134 ºC: polysulphone Lid and outlet hose nipple: polypropylene Inlet nut: Chromed brass Diffuser: Polyethylene Hose, flat gasket: Silicone Gasket: O-ring EPDMOutlet connection: Tapered hose nipple for hose 6×9 mm (recommended length 2 m)Cleaning: Water, non abrasive detergent. Never use solvents.Disinfection: An alcoholic solution, or other solution compatible with the material according to the disinfectant manufacturer.Autoclave: Polysulphone version 134 ºC for 18 minutesSpecial case: Diffuser: exchange at every cleaning - do not sterilise!Maintenance: Check that the humidifier is whole and air tight before use. Monthly exchange of gaskets is recommended. Exchange the diffuser when its microperforations no longer exist.Durability: Minimum 20 autoclave cycles under the condition that all instructions accompanying the product are adhered.

sPAre PArtsArt. Nr. DescriptionK301062 Jar 134 ºC K301064 Lid 134 ºC connection 9/16 UNF K301078 Lid 134 ºC connection G3/8 K294407 Inlet connection gasket 9/16 UNF, 10 pcs K294409 Bottle gasket 134 ºC, 10 pcs

COnsuMABLes Art. Nr. DescriptionK294434 Complete diffuser (tube 13 cm and diffuser, 10 pcs)

K294402

Page 31: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

29

sUCTIOn EQUIpMEnT

MEDIEVAC+•Compact and lightweight medical vacuum regulator system, which allows the user to efficiently and safely

control suction therapy•The suction level of the Medievac+ is regulated via an easy accessible, front mounted control knob•A special feature of the Medievac+ on-off valve is easy resumption of the selected de-pressure value, when

the treatment is interrupted •The Medievac+ gauge can easily be rotated, allowing the vacuum pressure to be clearly viewed

by the operator•The gauge scale is colour coded in sections to display a clear indication of suction level•Two versions of adjustable pressures are available to cover all therapy needs(-250 and –1000 mbar)•The –250 mbar version has a safety valve, which will automatically shut off to guarantee maximum protection

of the patient, in the unlikely event of de-pressure increase

the COMPACtness OF the DeviCe OFFers:•Fast connection to the vacuum source•Quick and convenient mounting of accessories (for example safety jar)•Good accessibility of other devices connected to close located terminal units

Page 32: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

30

MEDIEVAC+MEDIEVAC 1000-p DIn

• with plug for direct plugging into the wall outlet

• 360° rotatable gauge

• outlet thread 1/2" hose not included

• outlet thread for screwing the accessory security container or hose

• suction power adjustable up to -950 mbar

• alternatively Medievac 250 or 600, can be set to -250 or -600 mbar

MEDIEVAC+ 1000-r DIn

• with DIN rail clamp and hose 1.5 m

• otherwise Medivac DIN 1000-P

MEDIEVAC+ 250-p nf

• AFNOR (NF) connector for direct plug into the wall socket

• 360° rotatable gauge

• not outlet G1/2" hose included

• adjustable up to - 950 mbar

• Medievac 600 1000 or alternatively, set to -600 or -950 mbar

HOsE nIppLE 1/2”

• for bolting to the outlet terminal of the vacuum regulator

• for attachment of the suction hose

sAfETY JAr 100 ML

• for screwing onto the threaded outlet of the vacuum regulator

• captures secretion, which was aspirated by the suction of the safety device

• a ball valve prevents the ingress into the vacuum system of secretion

• outlet connector for direct plug of a suction hose or the bacteria filter

AnTIbACTErIAL fILTEr

• antibacterial filter for attachment to the output terminal of the containment

Page 33: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

31

teChniCAL DAtA

ON-OFF function: ON : green button visibleTo switch ON: push on the red buttonMax. inlet pressure: - 950 mbar (Measured from atmospheric pressure)Max. suction flow: 70 l/min ±5 l/minAccuracy of gauge: ±2,5 % of full scaleSafety valve: Medievac+ 250 only max. - 290 mbar openingInlet connection: According to national standardsOutlet connection: G1/2 maleHeight: 133 mm; 260 mm (with safety jar)Width: 63 mmDepth: 77 mm (without connector)Body material: ABSRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 10079-3 (Medical suction Equipment, Part 3: Suction equipment powered from a vacuum or pressure source).

Art. Nr. Description 0735115 MEDIEVAC+ 1000 -P DIN 0735131 MEDIEVAC+ 600 -P DIN 0735116 MEDIEVAC+ 250 -P DIN 0735142 MEDIEVAC+ 1000 -R DIN 0735143 MEDIEVAC+ 600 -R DIN 0735144 MEDIEVAC+ 250 -R DIN0735101 MEDIEVAC+ 1000 -P NF 0735102 MEDIEVAC+ 600 -P NF0735103 MEDIEVAC+ 250 -P NF 548900291594 Safety Jar 100ml K291603 Antibacterial filter pack of 10 548904281090 Hose nipple 1/2" for i MediEvac

MEDIEVAC+

120

152

133

63

77

Page 34: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

32

ACCEssOrIEs fOr MEDIEVAC

The Medievac+ vacuum regulator system includes an optional accessory, the safety jar. It is an additional protec-tion of the vacuum regulator and the hospital vacuum network, when the collection jars overflow. The filling capa-city of 100 ml and the safety valve function, provide the user with extra time to stop the suction therapy.

The jar can be easily and safely disconnected from the vacuum regulator and autoclaved at 134 °C for 18 minutes, in line with hospital protocols. GCE Mediline also recommends the use of the front mounted filter that is connected on the safety jar for increased safety. The plastic shell of the filter is very convenient to mount; it enables hygienic handling as direct contact with the membrane is avoided. The use of this filter is also recommended by the stan-dard (EN ISO 10079-3 part 6.5.2.1). Medievac+ compliance is based on EN ISO 10079-3 standard.

Art. Nr. Description548900291594 Safety jar 100 ml 548900291595 Safety jar 100 ml including filter K291603 Filter (×10)81462 Olive suction tip large81463 Olive suction tip smallK293492 Hose nipple G1/2 + O-ring

Page 35: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

33

sUCTIOn EQUIpMEnT

MEDIEJECT•The suction ejectors Medieject-32 and Medieject-33 come with either a metal bracket for rail mounting, with

a quick coupling for direct connection to gas outlet•The negative pressure can be seen clearly on the front-mounted gauge•The suction ejector has an ON/OFF control knob•The suction effect is regulated with a needle valve• It has a low sound level and requires a minimum of maintenance

Page 36: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

34

MEDIEJECT p

• Suction injector for direct insertion into gas outlets

• Air or O2 gas drive

• Suction power adjustable zero to minus 800 mbar

MEDIEJECT r

• MediEject as P, but for attaching to equipment rails, with 1.5 m hose

• Please order rail or wall mounting clamp 14090798 14090799 separately

sILEnCEr

prEssUrE GAUGE

On-Off VALVE KIT

HOsE nOZZLE wITH GAsKET

prEssUrE GAUGE GLAss

MEDIEJECT

14090844

14090843

373234346

373234427

373239898

373239827

373234473

Page 37: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

35

teChniCAL DAtAON-OFF function: ON: ON/OFF switch pulled OFF: ON/OFF switch pushedMax. inlet pressure: - 950 mbarMax. suction flow: 25 l/minMax. gas consumption: 38 l/minAccuracy of gauge: ± 2,5 %Inlet connection: According to the respective national standardOutlet connection: Hose nippleBody dimension: Height: 130 mm Width: 105 mm Depth: 53 mm without connectorWeight: 0,370 - 0,450 kg (depending on probe type)Temperature range: Storage: - 40 °C to 60 °C Operation: - 18 °C to 50 °CHumidity: max 70 % RHRegulatory status: Complies with medical devices directive 93/42/EEC. Complies with EN 10079 - 3 (medical suction equipment).Classification: Class IIaManufacturer: GCE, s.r.o, Žižkova 381 583 81 Chotěboř, CZ

Art. Nr. Description 14090844 MediEject -P DIN 14090843 MediEject -R DIN

sPAre PArts373234346 Silencer for MediEject 373234427 Pressure gauge for MediEject 373239908 Knob for MediEject 373239898 On-Off Valve Kit MediEject373239827 Hose nozzle with seal

MEDIEJECT • Positive gas pressure of the oxygen gas or air outlet is in MediEject according to the ejector in a vacuum (negative pressure) is converted.

• A knob, the suction can be adjusted and read on the pressure gauge (-80 KPa = - 800 mbar). The amount of the active vacuum is read directly on the manometer.

• About the ON/OFF pull the suction can be turned off and on while maintaining the set

• MediEject works very quietly

• The secretion MediEject device is clamped to either DIN rail or plugged with a quick coupling directly into the output of a gas supply.

115

96

130

105

Note! Measurements in mm.

Page 38: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

36

MEDICOLLECT 300

• Secretion collection bottle 0.3 l

• Inlet: 1/2" female thread

• Outlet: Hose

MEDICOLLECT 500

• Secretion collection bottle 0.5 l

• Inlet and outlet: Hose nipple

MEDICOLLECT 1000

• Secretion collection bottle 1.0 l

• Inlet and outlet: Hose nipple

MEDICOLLECT 2000

• Secretion collection bottle 2.0 l

• for insertion in the holding basket K291532

• Inlet and outlet: Hose nipple

MEDICOLLECT 2000 r

• Secretion collection bottle 2.0 l

• for insertion into the rail terminal 14090798 or wall mount

• Inlet and outlet: Hose nipple

MEDICOLLECT 4000

• Secretion collection bottle 2.0 l

• Inlet and outlet: Hose nipple

MEDICOLLECT

K291531

325196753

325196752

K291530

K291620

325196757

Page 39: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

37

ACCEssOrIEs - sUCTIOn bOTTLEs - wITH sInGLE UsE bAGs

suCtiOn BOttLes - sinGLe useD BAGsArt. Nr. Description 373234560 Suction bottle 2 l Complete with lid373234559 Suction bag 2 l (20 pcs)325113335 Suction bottle 1 l Add lid art. no. 325111944 to make complete325111952 Suction bag 1 l (20 pcs)

ACCessOriesArt. Nr. Description 373234593 Connection for suction bag325113237 Silicone hose; 25m; 6×129435440 Silicone hose; 5m; 6×129435450 Silicone hose; 1m; 6×12325111944 Lid for suction bottle9435440 Silicone hose; 5m; 6×129435450 Silicone hose; 1m; 6×12K291538 Catheter holder (without plate) K291539 Catheter holder (with plate)

373234560 325113335

373234559 325111952

325111944373234593

ACCEssOrIEs - sUCTIOn JArs - MEDICOLLECT 2000

Medicollect 2000 is a range of reusable jars for collection of secretion. For protected and hygienic use of unbreaka-ble material, guaranteed airtight, with an overflow valve and autoclavable material.

Art. Nr. DescriptionK291620 Medicollect 2000 with lid (134 °C)K291530 Medicollect 2000 with lid (121 ºC)

ACCessOries AnD sPAre PArtsArt. Nr. Description K305240 Rail clamp plastic for slitz plate K301069 Jar 134 ºCK290179 Complete overflow valve

COnsuMABLesArt. Nr. DescriptionK006968 Manual vacuum stop device, non sterile for adults

K291620

K291530

K291638 K291639

Page 40: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

38

HOLDInG bAsKET MEDICOLECT 500

HOLDInG bAsKET MEDICOLECT 1000

MOUnTInG AssEMbLY MEDICOLECT 2000

DIn rAIL CLAMp

• with withdrawable unit suitable for all MEDIEVAC and MEDICOLECT

wALL CLAMp

• as 18019014088 with 2 countersunk screws for mounting

DIn rAIL 1.0 M 25 × 10 MM

• stainless steel

• with 3 mounting feet per meter

sUCTIOn HOsE wITH fInGErTIp COnTrOLs

• Length 1.5 m

• Packaging unit 100 pcs

K291533

325196754

325196755

MEDICOLLECT

Page 41: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

39

MEDICOLLECT • With the MEDICOLECT secretions collecting bottle, the vacuum system.

• With the help of a ball valve against the ingress of secretion is protected.

• The bottles may be autoclaved at 121 °C 15 min.

• For different sized bottles are appropriate mounting bracket and rail terminals.

teChniCAL DAtAON-OFF-Funktion: switched on: black knob pulled off: press black buttonMaximum inlet pressure: 5,5 barMax suction: -800 mbarMaximum suction capacity: 25 l/minMaximum gas consumption: 38 l/minPressure gauge accuracy: ± 5% of readingInlet connector: Combination connector for Air or O2, DINOutlet: Hose nipple 7 to 9 mmBody dimensions:Height: 110 mmWidth: 104 mmDepth: 53 mm without plugStorage temperature range: -40 °C to +60 ° C at 40 - 70% RHWorking: -18 °C to +50 ° CWeight: 14090843 = 0,780 kg 14090844 = 0,430 kgBody material: ABSStandards and Regulations: meets the essential requirements of the Medical Devices Act (MPG MDD 93/42)Vacuum ejector: corresponds to class 2a medical device complies with EN ISO 10079-3Suction: corresponds to Class 1 medicalManufacturer: GCE Norden AB, Flygfaltsvagan 1, SE 2123 MalmöCE marking: CE0413CE marking: CE0434

Art. Nr. Description 14090844 MediEject -P DIN14090843 MediEject -R DIN373234346 Silencer for MediEject373234427 Pressure gauge for MediEject373239908 Knob for MediEject373239898 On-Off Valve Kit MediEject373239827 Hose nozzle with seal

Page 42: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

40

CLEAnnInG rECOMMEnDATIOns fOr MEDICOLLECT

Components Cleaning disinfection Rinsing in washer Sterilization

MediEvac complete devicein warm water and with mild house-hold Cleaners

disinfectant wipes with Terralin or comparable

no no

MediEject complete devicein warm water and with mild house-hold Cleaners

disinfectant wipes with Terralin or comparable

no no

Rail clamps, Wall clamps, Baskets for suc-tion bottles

complete devicein warm water and with mild house-hold Cleaners

disinfectant wipes with Terralin or comparable

Wash to 95 °CHot steam sterili-zation to 121 °C

returnable

secretion

collector

MediCollect

Clippings

all products warm Water and mild household Cleaners

all product dilute solution dipping followed by distilled rinse water and dry

Wash to 95 °CHot steam sterili-zation to 121 °C

Clippings

MediCollect 100Wash to 95 °C

Hot steam sterili-zation to 121 °C

secretion cover Wash to 95 °CHot steam sterili-zation to 121 °C

Ball Valve Anti-overflow -valve

Wash to 95 °C to 121 °C

connection hose Wash to 95 °C no

no

Suction with Fingertip

Re not allowed renew items once, with each patient

Antibacterial filter MediEject & MediEvac Re not allowed renew products, disposable, each patient use

Page 43: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

41

LOw prEssUrE HOsEs

•The dimensions and colours of our polyvinyl chloride manufactured, textile-reinforced hoses are in accordance with the current hospital standard

•Allowed working pressure max. 14 bar

•The hoses for medical breathing oxygen and nitrous oxide are marked with the chemical denomination of the gas

•The medical breathing air hose is marked ”AIR”

•Static

•Phthalates free

Art. Nr. Denomination Colour Max. Dimension Roll pressure (inner/outer) 14119013 Medical breathing oxygen White 14 bar 6/11 30 m14119020 Nitrous oxide Blue 14 bar 6/11 30 m14119015 Medical Breathing AIR Black/white 14 bar 8/14 30 m14119016 Medical Breathing AIR Black/white 14 bar 6,7/12,7 30 m14119024 Gas outlet Blue/brown 14 bar 12/17,4 30 m14119023 Vacuum/UTS Yellow 14 bar 10/16 30 m14119021 Carbon dioxide Grey 14 bar 6/11 30 m14119022 Mixed gas Red 14 bar 6/11 30 m14119017 O2/N2O White/blue 14 bar 6,7/12,7 30 m325113237 Suction hose Transparent - 6/12 25 m

Page 44: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

42

LOw prEssUrE HOsEs - MEDICOnnECT

•MediConnect is a new generation of flexible hoses for gas supply, intended for use with respiratory, anaesthetic and emergency equipment.

•Resistant to abrasion and change of colour

•Containing antistatic inner layer

•Neutral colours or according to colour coding of EN ISO 5359

•Wide range of country specific connections

•Lengths of hoses from 0,5 to 5 m; to be specified by customer

•Phthalates free

teChniCAL DAtAGas pressure: O2, AIR, N2O, vacuumMaterial: Polyvinyl chlorid, containing plasticizer, with brilliant polish, antistatic Inner/outer diameter: 6,7 × 12,7 mmWall: 3 mmHardness (Shore A): 88 ± 5Density: 1,25 ± 0,02 g/cm3

Tensile strength: = 10 MPaFracture strain: = 200 %Working pressure: max. 14 bar / 20 °CRupture pressure: 56 bar / 20 °C respectively 40 bar / 40 °COperation temperature: - 20 °C to + 60 °C

Nordic Standard Probe French Standard Probe British standard probe German Standard 120° Probe

Page 45: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

43

MEDICOnnECTLOw-prEssUrE HOsE sYsTEMs fOr MEDICAL GAsEs • Abrasion and discoloration-free tube with mirror finish • antistatic fabric • Phthalate free • neutral color or by color coding ISO 32 • a variety of country-specific connections available • Hose lengths 0.5 to 5 meters available • According to EN 739

We are forced by our ERP system to use article texts allow a maximum of 30 characters. Therefore, we often need to recourse abbreviations which should nevertheless allow you to article texts that appear on invoices and delivery notes a ausage the quality of the product make.

exPLAnAtiOnHOsE O2 bL 0,5M DIn120 / DInQC

HOsE hose

OUTLETas inlet ports, additional variants: DIN QC = DIN Quick Coupler NF QC = NF Quick couple NIST = NIST straight NIST 90° = NIST 90° angledR 1/4“INT = VAC Connection for 1/4" female thread

InLET DIN90° = DIN plug 90° angledDIN120 DIN connector angled = 120°M 12×1 = Screw gas-specific O2 with M12×1 thread M17×1 = screw gas-specific

AIR with M17×1 thread M 14×1 = Screw gas-specific N2O with M14×1 thread M 15×1 = Screw gas-specific O2/AIR with M15×1 thread M 20×1,5 = Screw gas-specific AIR with M20×1,5 thread NF 90 = 90 standard Francaise plug 90° angled NF = standard Francaise Plug straight

LEnGHT 0,5M - 5 m

fOrM SP3 Spiral hose 3m

COLOUrs BL black WH whiteBL/WH black/white GR greenBLUE blueYEL yellow

GAs O2 AIR N20 CO2 Vac

teChniCAL DAtAMaterial: Polyvinyl chloride, plasticizers containingTextile reinforcement: with high-gloss, latex freeInner diameter: 6,40 – 6,70 mmWall thickness: 2,70 – 3,15 mmShore A hardness: 87 ± 5 (applies to Rolls unprocessed)Density: 1,25 ± 0,02 g/cm3

Tensile strength: 10 MPa3

Elongation at break: 200 %Antistatic:Weight: 110 g (1 m hose without fittings)Operating pressure: max. 14 bar / 20 °C (applies to Rolls unprocessed)Burst pressure: 56 bar / 20 bar and 40 °C / 40 °COperating temperature: 20 °C to 65 °CMax print area in use: From 3.0 to 14 bar 0.1 to 1.0 bar absolute pressure for vacuum hoseMaximum pressure drop: <500 mbar at 3.2 bar and 200 l/minMaximum tensile forces: 600 N, 300 N for vacuumTemperature: -40 °C to +75 °COperating temperature: -20 °C to +60 °CHumidity: 5% to 95% RHBarometer: 570-1200 hPaMaximum life span: 10 years from date of manufactureStandards:Conforms to: the basic requirements of Medical Devices Act (MPG MDD93/42)Conforms to: Medical Device Class 2aMet: EN ISO 5359CE mark: CE0434Manufacturer: GCE sro, 58381 Chotebor, CZ

Page 46: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

44

MEDICOnECT HOsE O2

O2 Din neutrAL COLOr BLACKArt. Nr. Description 0731132 HOSE O2 BL 0,5m DIN120/DIN900731100 HOSE O2 BL 0,5m DIN120/DINQC0731124 HOSE O2 BL 0,5m DIN120/M12×10731108 HOSE O2 BL 0,5m DIN120/NIST0731116 HOSE O2 BL 0,5m DIN120/NIST900731148 HOSE O2 BL 0,5m M15×1/NIST900731133 HOSE O2 BL 1,5m DIN120/DIN900731101 HOSE O2 BL 1,5m DIN120/DINQC0731125 HOSE O2 BL 1,5m DIN120/M12×10731109 HOSE O2 BL 1,5m DIN120/NIST0731117 HOSE O2 BL 1,5m DIN120/NIST900731134 HOSE O2 BL 3m DIN120/DIN900731102 HOSE O2 BL 3m DIN120/DINQC0731126 HOSE O2 BL 3m DIN120/M12×10731110 HOSE O2 BL 3m DIN120/NIST0731118 HOSE O2 BL 3m DIN120/NIST900731135 HOSE O2 BL 5m DIN120/DIN900731103 HOSE O2 BL 5m DIN120/DINQC0731127 HOSE O2 BL 5m DIN120/M12×10731111 HOSE Ov BL 5m DIN120/NIST0731119 HOSE O2 BL 5m DIN120/NIST900731142 HOSE O2 BL SP1,5 DIN120/M12×10731140 HOSE O2 BL SP1,5 DIN120/NIST900731143 HOSE O2 BL SP3 DIN120/M12×10731141 HOSE O2 BL SP3 DIN120/NIST90

O2 Din isO COLOr CODeD white Art. Nr. Description 0731136 HOSE O2 WH 0,5m DIN120/DIN900731104 HOSE O2 WH 0,5m DIN120/DINQC0731128 HOSE O2 WH 0,5m DIN120/M12×10731112 HOSE O2 WH 0,5m DIN120/NIST0731120 HOSE O2 WH 0,5m DIN120/NIST900731149 HOSE O2 WH 0,5m M15×1/NIST900731137 HOSE O2 WH 1,5m DIN120/DIN900731105 HOSE O2 WH 1,5m DIN120/DINQC0731129 HOSE O2 WH 1,5m DIN120/M12×10731113 HOSE O2 WH 1,5m DIN120/NIST0731121 HOSE O2 WH 1,5m DIN120/NIST900731138 HOSE O2 WH 3m DIN120/DIN900731106 HOSE O2 WH 3m DIN120/DINQC0731130 HOSE O2 WH 3m DIN120/M12×10731114 HOSE O2 WH 3m DIN120/NIST0731122 HOSE O2 WH 3m DIN120/NIST900731139 HOSE O2 WH 5m DIN120/DIN900731107 HOSE O2 WH 5m DIN120/DINQC0731131 HOSE O2 WH 5m DIN120/M12×10731115 HOSE O2 WH 5m DIN120/NIST0731123 HOSE O2 WH 5m DIN120/NIST900731146 HOSE O2 WH SP1,5 DIN120/M12×10731144 HOSE O2 WH SP1,5 DIN120/NIST900731147 HOSE O2 WH SP3 DIN120/M12×10731145 HOSE O2 WH SP3 DIN120/NIST90

Page 47: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

45

MEDICOnECT HOsE O2

O2 AFnOr neutrAL COLOr BLACKArt. Nr. Description 0731211 HOSE O2 BL 0,5m NF90/M12×10731219 HOSE O2 BL 0,5m NF90/NF0731187 HOSE O2 BL 0,5m NF90/NFQC0731195 HOSE O2 BL 0,5m NF90/NIST0731203 HOSE O2 BL 0,5m NF90/NIST900731212 HOSE O2 BL 1,5m NF90/M12×10731220 HOSE O2 BL 1,5m NF90/NF0731188 HOSE O2 BL 1,5m NF90/NFQC0731196 HOSE O2 BL 1,5m NF90/NIST0731204 HOSE O2 BL 1,5m NF90/NIST900731227 HOSE O2 BL 1,5m NF90NF900731213 HOSE O2 BL 3m NF90/M12×10731221 HOSE O2 BL 3m NF90/NF0731228 HOSE O2 BL 3m NF90/NF900731189 HOSE O2 BL 3m NF90/NFQC0731197 HOSE O2 BL 3m NF90/NIST0731205 HOSE O2 BL 3m NF90/NIST900731214 HOSE O2 BL 5m NF90/M12×10731222 HOSE O2 BL 5m NF90/NF0731190 HOSE O2 BL 5m NF90/NFQC0731198 HOSE O2 BL 5m NF90/NIST0731206 HOSE O2 BL 5m NF90/NIST90

O2 AFnOr isO COLOr CODeD white Art. Nr. Description 0731215 HOSE O2 WH 0,5m NF90/M12×10731223 HOSE O2 WH 0,5m NF90/NF0731191 HOSE O2 WH 0,5m NF90/NFQC0731199 HOSE O2 WH 0,5m NF90/NIST0731207 HOSE O2 WH 0,5m NF90/NIST900731216 HOSE O2 WH 1,5m NF90/M12×10731224 HOSE O2 WH 1,5m NF90/NF0731229 HOSE O2 WH 1,5m NF90/NF900731192 HOSE O2 WH 1,5m NF90/NFQC0731200 HOSE O2 WH 1,5m NF90/NIST0731208 HOSE O2 WH 1,5m NF90/NIST900731217 HOSE O2 WH 3m NF90/M12×10731225 HOSE O2 WH 3m NF90/NF0731230 HOSE O2 WH 3m NF90/NF900731193 HOSE O2 WH 3m NF90/NFQC0731201 HOSE O2 WH 3m NF90/NIST0731209 HOSE O2 WH 3m NF90/NIST900731218 HOSE O2 WH 5m NF90/M12×10731226 HOSE O2 WH 5m NF90/NF0731194 HOSE O2 WH 5m NF90/NFQC0731202 HOSE O2 WH 5m NF90/NIST0731210 HOSE O2 WH 5m NF90/NIST90

Page 48: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

46

MEDICOnECT HOsE O2 O2 nist neutrAL COLOr BLACK

Art. Nr. Description 0731148 HOSE O2 BL 0,5m M15×1/NIST900731279 HOSE O2 BL SP 3m M12×1/M12×10731280 HOSE O2 BL SP 3m M12×WALTHER

O2 nist isO COLOr CODeD white Art. Nr. Description 0731149 HOSE O2 WH 0,5m M15×1/NIST900731277 HOSE O2 WH 0,5m NIST/M15×10731278 HOSE O2 WH 1,5m NIST/M15×10731284 HOSE O2 WH 1m M15×1/NIST0731286 HOSE O2 WH 0,5m 9/16/NIS

MEDICOnECT HOsE AIr Air Din neutrAL COLOr BLACK

Art. Nr. Description 0731150 HOSE AIR BL 0,5m DIN120/DINQC0731151 HOSE AIR BL 1,5m DIN120/DINQC0731152 HOSE AIR BL 3m DIN120/DINQC0731153 HOSE AIR BL 5m DIN120/DINQC0731154 HOSE AIR BL 0,5m DIN120/NIST0731155 HOSE AIR BL 1,5m DIN120/NIST0731156 HOSE AIR BL 3m DIN120/NIST0731157 HOSE AIR BL 5m DIN120/NIST0731158 HOSE AIR BL 0,5m DIN120/NIST900731159 HOSE AIR BL 1,5m DIN120/NIST900731160 HOSE AIR BL 3m DIN120/NIST900731161 HOSE AIR BL 5m DIN120/NIST900731162 HOSE AIR BL 0,5m DIN120/M20×1,50731163 HOSE AIR BL 1,5m DIN120/M20×1,50731164 HOSE AIR BL 3m DIN120/M20×1,50731165 HOSE AIR BL 5m DIN120/M20×1,50731166 HOSE AIR BL 0,5m DIN120/DIN900731167 HOSE AIR BL 1,5m DIN120/DIN900731168 HOSE AIR BL 0,5m M20×1,5/NIST90

MEDICOnECT HOsE AIr Air Din isO COLOr CODeD BLACK/white

Art. Nr. Description 0731500 HOSE AIR BL/WH 0,5m DIN120/DINQC0731501 HOSE AIR BL/WH 1,5m DIN120/DINQC0731502 HOSE AIR BL/WH 3m DIN120/DINQC0731503 HOSE AIR BL/WH 5m DIN120/DINQC0731504 HOSE AIR BL/WH 0,5m DIN120/NIST0731505 HOSE AIR BL/WH 1,5m DIN120/NIST0731506 HOSE AIR BL/WH 3m DIN120/NIST0731020 HOSE AIR BL/WH 5m DIN120/NIST0731507 HOSE AIR BL/WH 0,5m DIN120/NIST900731508 HOSE AIR BL/WH 1,5m DIN120/NIST900731509 HOSE AIR BL/WH 3m DIN120/NIST900731510 HOSE AIR BL/WH 5m DIN120/NIST900731511 HOSE AIR BL/WH 0,5m DIN120/M20×1,50731512 HOSE AIR BL/WH 1,5m DIN120/M20×1,50731513 HOSE AIR BL/WH 3m DIN120/M20×1,50731514 HOSE AIR BL/WH 5m DIN120/M20×1,50731515 HOSE AIR BL/WH 0,5m DIN120/DIN900731516 HOSE AIR BL/WH 1,5m DIN120/DIN90

Page 49: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

47

Air AFnOr neutrAL COLOr BLACKArt. Nr. Description 0731243 HOSE AIR BL/WH 0,5m NF90/M20×1,50731247 HOSE AIR BL/WH 0,5m NF90/NF0731231 HOSE AIR BL/WH 0,5m NF90/NFQC0731235 HOSE AIR BL/WH 0,5m NF90/NIST0731239 HOSE AIR BL/WH 0,5m NF90/NIST900731260 HOSE AIR BL/WH 1,5m NF90/M14×10731244 HOSE AIR BL/WH 1,5m NF90/M20×1,50731248 HOSE AIR BL/WH 1,5m NF90/NF0731232 HOSE AIR BL/WH 1,5m NF90/NFQC0731236 HOSE AIR BL/WH 1,5m NF90/NIST0731240 HOSE AIR BL/WH 1,5m NF90/NIST900731261 HOSE AIR BL/WH 3m NF90/M14×10731245 HOSE AIR BL/WH 3m NF90/M20×1,50731249 HOSE AIR BL/WH 3m NF90/NF0731233 HOSE AIR BL/WH 3m NF90/NFQC0731237 HOSE AIR BL/WH 3m NF90/NIST0731241 HOSE AIR BL/WH 3m NF90/NIST900731262 HOSE AIR BL/WH 5m NF90/M14×10731246 HOSE AIR BL/WH 5m NF90/M20×1,50731250 HOSE AIR BL/WH 5m NF90/NF0731234 HOSE AIR BL/WH 5m NF90/NFQC0731238 HOSE AIR BL/WH 5m NF90/NIST0731242 HOSE AIR BL/WH 5m NF90/NIST90

MEDICOnECT HOsE AIr Air AFnOr isO COLOr CODeD BLACK/white

Art. Nr. Description 0731517 HOSE AIR BL/WH 0,5m NF90/NFQC0731518 HOSE AIR BL/WH 1,5m NF90/NFQC0731519 HOSE AIR BL/WH 3m NF90/NFQC0731520 HOSE AIR BL/WH 5m NF90/NFQC0731521 HOSE AIR BL/WH 0,5m NF90/NIST0731522 HOSE AIR BL/WH 1,5m NF90/NIST0731523 HOSE AIR BL/WH 3m NF90/NIST0731524 HOSE AIR BL/WH 5m NF90/NIST0731525 HOSE AIR BL/WH 0,5m NF90/NIST900731526 HOSE AIR BL/WH 1,5m NF90/NIST900731527 HOSE AIR BL/WH 3m NF90/NIST900731528 HOSE AIR BL/WH 5m NF90/NIST900731529 HOSE AIR BL/WH 0,5m NF90/M20×1,50731530 HOSE AIR BL/WH 1,5m NF90/M20×1,50731531 HOSE AIR BL/WH 3m NF90/M20×1,50731532 HOSE AIR BL/WH 5m NF90/M20×1,50731533 HOSE AIR BL/WH 0,5m NF90/NF0731534 HOSE AIR BL/WH 1,5m NF90/NF0731535 HOSE AIR BL/WH 3m NF90/NF0731536 HOSE AIR BL/WH 5m NF90/NF

Air nist neutrAL COLOr BLACK

Art. Nr. Description 0731168 HOSE AIR BL 0,5m M20×1,5/NIST900731273 HOSE AIR BL 0,5m NIST/M17×10731274 HOSE AIR BL 1,5m NIST/M17×1

Air nist isO COLOr CODeD BLACK/white

Art. Nr. Description 0731275 HOSE AIR BL/WH 0,5M NIST/M17×10731276 HOSE AIR BL/WH1,5M NIST/M17×10731020 HOSE AIR BL/WH 5M DIN120/NIST

Page 50: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

48

MEDICOnECT HOsEs VACUUM AnD n2O DUE TO THE rELATIVELY sMALL nUMbErs ArE OnLY COLOr CODED n2O hOses Din

Art. Nr. Description 0731169 HOSE N2O BLUE 1,5m DIN120/DINQC0731178 HOSE N2O BLUE 1,5m DIN120/M14×10731172 HOSE N2O BLUE 1,5m DIN120/NIST0731175 HOSE N2O BLUE 1,5m DIN120/NIST900731170 HOSE N2O BLUE 3m DIN120/DINQC0731179 HOSE N2O BLUE 3m DIN120/M14×10731173 HOSE N2O BLUE 3m DIN120/NIST0731176 HOSE N2O BLUE 3m DIN120/NIST900731171 HOSE N2O BLUE 5m DIN120/DINQC0731180 HOSE N2O BLUE 5m DIN120/M14×10731174 HOSE N2O BLUE 5m DIN120/NIST0731177 HOSE N2O BLUE 5m DIN120/NIST90

n2O hOses AFnOr

Art. Nr. Description 0731263 HOSE N2O BLUE 0,5m NF90/NF0731264 HOSE N2O BLUE 1,5m NF90/NF0731251 HOSE N2O BLUE 1,5m NF90/NFQC0731254 HOSE N2O BLUE 1,5m NF90/NIST0731257 HOSE N2O BLUE 1,5m NF90/NIST900731265 HOSE N2O BLUE 3m NF90/NF0731252 HOSE N2O BLUE 3m NF90/NFQC0731255 HOSE N2O BLUE 3m NF90/NIST0731258 HOSE N2O BLUE 3m NF90/NIST900731266 HOSE N2O BLUE 5m NF90/NF0731253 HOSE N2O BLUE 5m NF90/NFQC0731256 HOSE N2O BLUE 5m NF90/NIST0731259 HOSE N2O BLUE 5m NF90/NIST90

vACuuM hOses Din

Art. Nr. Description 0731181 HOSE VAC YEL 1,5m DIN120/NIST0731184 HOSE VAC YEL 1,5m DIN120/R1/4 INT0731182 HOSE VAC YEL 3m DIN120/NIST0731185 HOSE VAC YEL 3m DIN120/R1/4 INT0731183 HOSE VAC YEL 5m DIN120/NIST0731186 HOSE VAC YEL 5m DIN120/R1/4 INT

vACuuM hOses AFnOr Art. Nr. Description 0731267 HOSE VAC YEL 1,5m NF90/NIST0731270 HOSE VAC YEL 1,5m NF90/R1/4 INT0731268 HOSE VAC YEL 3m NF90/NIST0731271 HOSE VAC YEL 3m NF90/R1/4 INT0731269 HOSE VAC YEL 5m NF90/NIST0731272 HOSE VAC YEL 5m NF90/R1/4 INT

Page 51: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

49

MEDICOnECT HOsEsHOsE O2 DIss-nIsT Gr 1,5m spr

• Working length 1.5 m

• outer spiral Diameter 60 mm

• inner coil diameter 82 mm

• Inlet DISS fitting

• NIST outlet screw

HOsE O2 nf M12×1 wH 3m spr

• Working length 3 m

• outer spiral Diameter 60 mm

• inner coil diameter 82 mm

• white

HOsE O2 DIn-nIsT nEUTr 1,5m

• O2 DIN 120 ° - NIST just

• 1.5 m long

• color neutral

HOsE O2 M15×1 nIsT nEUTr 0,5m HOsE O2 M15×1 nIsT nEUTr 0,5m

• O2 M15×1 - NIST

• 0,5 m long

• color neutral

HOsE O2 nf-nf wH 1,5m

• O2 AFNOR-AFNOR

• 1,5 m long

• white

eLeMents OF PrODuCt sAFety Secretion collection bottle 2.0 l Inlet and outlet: Hose nipple

Page 52: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

50

COnneCtOrs AnD quiCK COuPLes Art. Nr. Description

14090390 DIN connector O2, 120°14116042 DIN connector O2, 90°14090391 DIN connector AIR, 120°14116043 DIN connector AIR, 90°14090392 DIN connector N2O, 120°14116021 DIN connector VAC, 120°14090284 Combined O2/AIR DIN connector, 120°14090845 Combined DIN connector O2/AIR, M10×1A14090841 Combined O2/AIR DIN connector, 3/8" i9410970 DIN Quick Couple O2, 3/8" A9423410 DIN Quick Couple O2, 1/4" A9410980 DIN Quick Couple AIR, 3/8" A9410990 DIN Quick Couple AIR, 1/4” A9401320 DIN N2O Quick Couple, 3/8" A14090963 Walther Quick Couple, 1/8" A9417770 Gasket for 3/8" Quick Couple 10 pcs9421510 Gasket for 1/4" Quick Couple 10 pcs14090227 DIN hose nipple O2, M12×19439830 DIN AIR nozzle, M20×1,59439820 DIN hose nipple N2O, M14×114116037 DIN hose nipple AIR/O2, M15×114116035 NIST O2 plug, straight14116033 NIST connector AIR, just14116401 NIST O2/AIR plug, straight14116045 NIST plug O2, 90°9441980 AIR NIST plug, 90°9441990 NIST connector N2O, 90°14116030 NIST female couple O2

14116028 NIST female couple AIR

The options listed are a selection of the available country-specific variants with hoses that can be supplied.

14116042

14090284 14090963

14090845

9410970

14090227

14116030

14090391

14116035

14116045

COnnECTOrs AnD QUICK COUpLEs

Page 53: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

51

MEDICOnnECT- COnnECTOrs AnD QUICK COUpLEs nOrDIC

COnneCtOrs AnD quiCK COuPLesArt. Nr. Description 325110382 NORDIC O2 connector, 6 mm325100222 NORDIC N2O connector, 6 mm325100223 NORDIC AIR connector, 8 mm325100330 NORDIC N2 connector, 6 mm325111116 NORDIC CO2 connector, 6 mm325100224 NORDIC connector VAC, 10 mm325100784 NORDIC gas outlet connector, 12 mm325110115 NORDIC connector INSTRUM, 8 mm325110357 NORDIC MEDIMIX connector, 6 mm325196831 NORDIC connector 90° O2, 6 mm325195762 NORDIC connector 90° N2O, 6 mm325195761 NORDIC Stecker 90° AIR, 8 mm325195763 NORDIC connector 90° VAC, 10 mm325196353 NORDIC gas outlet connector 90°325196657 NORDIC INSTR connector 90°, 8 mm325196853 NORDIC Quick Couple O2, 6 mm325195089 NORDIC Quick Couple N2O, 6 mm325196793 NORDIC Quick Couple MEDIMIX, 6 mm325195091 NORDIC AIR Quick Couple, 8 mm325197149 NORDIC Quick Couple CO2, 6 mm325196919 NORDIC Quick Couple INSTRUM, 8 mm325195092 NORDIC Quick Couple VAC, 10 mm325195788 NORDIC Quick Couple outlet, 12 mm325196247 NORDIC-T Quick Couple O2, 6 mm325196248 NORDIC-T Quick Couple AIR, 8 mm325396735 NORDIC Quick Couple 2-O2, rail325396764 NORDIC Quick Couple 2-AIR

325196831325110382 325100222

325396735325196247325196853

Page 54: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

52

MEDICOnnECT- COnnECTOrs AnD QUICK COUpLEs

COnneCtOrs AnD quiCK COuPLes Art. Nr. Description

14116056 AIR connector NF, 90°14116053 NF connector O2

K007841 NF connector O2, 90°K007844 AIR connector NF, 90°K007843 N2O NF connector, 90°K007852 NF VAC connector, 90°K007861 NF connector O2

K007864 NF connector AIRK007863 NF connector N2OK007866 NF connector CO2

K007872 NF VAC connector9418920 NF Quick Couple 3/8A O2

9432300 NF Quick Couple 3/8A AIR9442010 NF Quick Couple 3/8A N2O9432310 NF Quick Couple VAC 3/8A9417930 NF Quick Couple 1/4A O2

9433300 NF Quick Couple 1/4A AIR9433310 NF Quick Couple 1/4A N2OK292339 NF Quick Couple VAC 1/4A14116063 KAWASAKI O2 connector, straight14116064 KAWASAKI Quick Couple O2

14116067 Junron O2 connector, straight14116066 Junron Quick Couple O2

14116062 MZ LIBEREC O2 connector, straight9420500 MZ LIBEREC Quick Couple O2

14116065 AUSTRALIA O2 connector, straight9412930 AUSTRALIA Quick Couple O2, 3/8, UNI connector, consists of 3 parts MD35010, H03825673, 9417920 MD35010 UNI connector E: G1/4" insideH03825673 Hose G1/4"/ 6 mm hose nipple9417920 Gasket 11,1×8,5 10 STMD35100 UNI Quick Couple O2

9432960 BSI Quick Couple O2, BSI connector, consists of the following two parts MM3274, 14090146MM3274 BSI O2 connector straight14090146 Hose nozzle with union nut G3/8”9413000 DISS connector9412980 DISS Quick Couple 3/8”9449670 Rectus QC Type 20L, pack of 1 unit

The options listed are a selection of the available country-specific versions, which can be supplied with hoses.

MM3274 +14090146

14116065

14116062

14116056

14116053

9432960 94129809412930 9417930

9418920

K007844

K007843

K007852

K007861

K007863K007864

K007872

9420500

Uni Stecker MD35010, H3825673,

9417920

9413000

14116063

14116064

14116066

Page 55: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

53

MEDICOnnECT- ADApTEr AnD HOsE nIppLEs ADAPter

Art. Nr. Description 14090277 Adapter 3/8”A - 9/16A14090748 Adapter 3/8”I - 1/8A14090865 Adapter 3/8”I - 3/8I14090099 Adapter 3/8”I - 9/16A14090192 Adapter 3/8”I - M10×1A14116040 Adapter 3/8”I - M10×1A14090093 Adapter 3/8”I - M12×1,25A14115017 Adapter 3/8”I - M12×1A14090252 Adapter 9/16”I - 3/8A FLACH14090268 Adapter 9/16”I - 3/8A KONI14115027 Adapter 9/16”I - 9/16”A14090090 Adapter 9/16”I - M12×1,25A14090281 Adapter G1/4”I - 9/16A14090278 Adapter M10×1A - 9/16A14115021 Adapter M10×1A - M12×1I14090721 Adapter M12×1A - 3/8A14090094 Adapter M12×1,25I - 3/8A9404780 Adapter M12×1,25II - 9/16A14090276 Adapter M18×1A - 9/16A14090282 Adapter M18×1I - 9/16A14090296 Adapter M22×1,5I - 9/16A14090279 Adapter M24×1,5A - 9/16A14090280 Adapter M24×1,5I - 9/16A14090274 Adapter M32×1,5A - 9/16A14090288 Adapter M34×1,5A - 9/16A14090283 Adapter W17,4×19I - 9/16A

hOse niPPLesArt. Nr. Description 14090089 Hose nipple 4-6 mm tree, 9/16"I14090095 Hose nipple 6 mm fixed, 3/8”I14090271 Hose nipple 6 mm fixed, 9/16”A14090085 Hose nipple 6 mm fixed, 9/16”I14090888 Hose nipple 6 mm fixed, G1/8”A14090087 Hose nipple 6 mm fixed, M12×1,25I14090938 Hose nipple 6 mm, 3/8”I flach14090145 Hose nipple 6 mm, 3/8”I KONI14090147 Hose nipple 6 mm, 9/16”I14090227 Hose nipple 6 mm, M12×1A9439820 Hose nipple 6 mm, M14×1A14116037 Hose nipple 6 mm, M15×1A14090144 Hose nipple 6 mm, M16×1,5I9439830 Hose nipple 6 mm, M20×1,5I14090146 Hose nipple 6 mm, 90°, 3/8”I14090148 Hose nipple 6 mm, 90°, 9/16”I

14090271

14090888

14090146

14090146

14090268 14090278

14090282 14090288

14090296

14090089

14090095

exPLAnAtiOnHOsE nIppLE 6 mm fIXED, M12 × 1,25I With push-on hose 6 mm, fixed (non-rotatable) M12×1,25 female thread

HOsE nIppLE 6 mm, 3/8”I KOnI With 6 mm push-on hose, 3/8" female, with cone seal

ADApTEr 9/16”I - 3/8A fLACH Adapter with 9/16" female thread, other side has 3/8" male thread, flat sealing

14090095

Page 56: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

54

TrOLLEYsTrOLLEYs

Art. Nr. Description 14090630 Trolley for 10 l cylinder, 5-wheels, static325396136P Trolley for 10 or 20 l cylinder, without belt Dimensions H×W×D (mm): 935×426×352 325396137 Trolley for 10, 20 l cylinders, 3×10 l or 2×20 l without belt Dimensions H×W×D (mm): 935×710×352325397691 Trolley for gas cylinder, D=116 mm

ACCessOriesArt. Nr. Description Trolley500009602 Belt for 2.5 l cylinder 500009601P325396138 Belt for 5 or 10 l cylinder 500009601P, 325396136, 325396137325396139 Belt for 20 l cylinder 325396136, 325396137

CYLInDEr HOLDErsCYLInDEr HOLDErs

Art. Nr. Description 14090635 Holder for 2 l cylinder (1 belt), D = 100 mm 14116016 Holder for 2 or 3 l cylinder (2 belts), D = 100 mm 500003472 Holder for 2 l cylinder (foot)325197566P Holder for gas cylinder, D = 116 mm325197688P Holder for gas cylinder, D = 100 mm

ACCessOriesArt. Nr. Description326001695 Bed hanger bracket326000722 T-Bracket

14090630325396136P 325396137 325397691

326001695

14090635

500003472

325197566P

325197688326000722

HOMECArE

Page 57: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

HOMECArE

Page 58: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

56

ECOlite® 4000 Is An ELECTrOnIC OXYGEn GAs COnsErVInG DEVICE, wHICH EnAbLEs pATIEnT frIEnDLY AnD EffICIEnT LOnG TErM OXYGEn THErApY

TrEATMEnT (LTOT).

•With the ECOlite® 4000, oxygen is delivered only during the inspiration phase, permitting savings of up to 10 times compared to continuous flow oxygen therapy

•The volume of oxygen needed for one breath is delivered during the first third of the inspiratory cycle, which guarantees both efficient and optimal treatment and a short exposure of the nasal mucosa to medical oxygen.

•A special feature of the ECOlite® 4000 is the small, internal regulator, that allows the user to select a supply inlet pressure of between 1,6 to 5 bar. The working pressure of the device is regulated to 1,6 bar which enables a both clinically and physiologically patient friendly oxygen administration. The device has two operating modes, Automatic and Manual

• In the Automatic mode the amount of oxygen delivered increases in relation to the set flow rate at breath rates of 15 to 30 breaths per minute, to a maximum of 8 l/min. In the Manual mode the flow rates are from 0,5 to 8 l/min with 0,5 l/min steps

• If a specific flow rate is prescribed by the physician to be administrated, the flow settings can be locked at any rate by the health care personnel in charge of setting the flows on initial setup

•The device has several built in alarm functions for safe use. The alarms are shown on the display and are also audible

the eCOLite® 4000 hAs ALArMs FOr: •Low battery•No oxygen•No breathing

The battery life time of the device is prolonged to last for 200 hours. Standard AA 1,5 volt batteries are in use.

OXYGEn COnsErVInG DEVICE

ECOlite® 4000

Page 59: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

57

1517

2024

30

12

46

8 0,05,010,015,020,025,030,035,040,045,050,055,060,065,070,075,080,085,0

Setting

Breath/min

Liter/min

Automatic mode

12468

ECOlite® 4000 OXYGEn COnsErVEr

envirOnMentAL PrOteCtiOnThere are no known risks associated with disposal the ECOlite® 4000 at the end of its working life.Batteries and electronics should be disposed of at an approved recycling facility. Other parts shall be recycled according to local regulations.

reGuLAtOry stAtusEuropean Economic Area (EEA): This mark on the product indicates compliance with Directive 93/42/EEC relating to medical devices, Class IIa.

MAnuFACturers inFOrMAtiOnThe ECOlite® 4000 is manufactured at GCE.The month and year of manufacture is shown on the serial number label on the rear of the unit.

Other than the consumables/accessories/spare part listed above there are no user replaceable parts. Only qualified service personnel, certified by the manufacturer, may attempt any repair to the ECOlite® 4000. Not following this instruction will disqualify the manufacturers guarantee.

Art. Nr. Description325197544 ECOlite® 4000 COMPL SE 325197617 ECOlite® 4000 COMPL 1,6 bar

COnsuMABLesArt. Nr. Description306798P Standard Nasal cannula, 10 pcs325112717 Spiral Hose SE325112783 Spiral Hose 1,6 bar

ACCessOriesArt. Nr. Description14090535 ECOlite® 4000 Carry Bag14090631 ECOlite® 4000 Carry Bag Trolley325112719 Belt bag for ECOlite® 4000

sPAre PArtsArt. Nr. Description325112670 Battery cover

teChniCAL DAtA fUnCTIOnAL pErfOrMAnCESettings: Manual/Automatic Triggering: At each breathSensitivity: 0,13 cm H2ORegulating pressure: 1,6 barAccuracy: 0,5-1,5 l/min +/- 30% 2-8 l/min +/- 15% Cycle output: 0.5 to 8 l/min coresponding to 5-80 ml per bolusAlarms: Battery monitoring Missing Oxygen supply No inhalation

pOwEr sUppLY Battery: RO6, AA, Alkaline 1,5 VOxygen supply Pressure: Between 1,6 and 5 barFlow: Minimum 4 liters per minute

DIMEnsIOns AnD wEIGHT Dimensions: Height: 101 mm Width: 85 mm Depth: 32 mmWeight: 184 g without battery

EnVIrOnMEnTAL COnDITIOnAmbient temperature:Operational: -10°C to +40°CStorage: -40°C to +70°CRelative humidity: 25% to 95%

14090535 14090631

325112719

PAtenteD1516642

0434

Page 60: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

58

ACCEssOrIEs fOr GAs sAVEr

Art. Nr. Description14090500 Oxygen mask for adults under chin, single use

Art. Nr. Description14090509 Oxygen mask for children age to 1 to 10+, single use

Art. Nr. Description14175080 Nasal cannula

Art. Nr. Description14175085 Nasal cannula, flared

14090500

14090509

14175080

14175085

teChniCAL DAtA Hose length: 1.8 mMaterial: Soft material for best wearing comfort and optimal patienthandlingPVC Connection: StandardPackage: 50 pcs

teChniCAL DAtA Hose length: 2.1 mPackage: 50 pcs

teChniCAL DAtA Hose length: 2.1 mPackage: 50 pcs

teChniCAL DAtA Hose length: 2.1 mMaterial: Soft material for best wearing comfort and optimal patienthandlingPVC Connection: StandardPackage: 50 pcs

Page 61: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

59

teChniCAL DAtA Operating voltage: 230 V, 50 HzPower consumption: 290 WFuse: 5 A O2 concentration: bei 2 l/min: >90% bei 5 l/min: 90 % (+6,5% - 3%)Operating noise: <40 dBAStorage temperature: -20 to +60 °CAmbient temperature: +5 to +40 °CWeight: 13,6 kgDimensions (W×H×D): 35 × 22 × 58 cmWorking principle: PSA (pressure swing absorbation)Standards: ISO 8359, EN 60601-1Medical devices class: IIbCE mark: CE0413Garantie: 5 yearsManufacturer: Nidek, Birmingham, AL 35217 USA

OXYGEn COnCEnTrATOrnUVO LITE MArK 5

• Low weight of 13.6 kg • space-saving and portable design with integrated carrying handle • Flow adjustment knob lockable • Flow from 0.125 to 5 l/min adjustable • faster, back access to filters and operating hours counter

Art. Nr. Description14111211 Concentrator Mark 5 Nuvo Lite14111220 Main filter14111222 Back filter14090329 Antibacterial filter14090417 Disposable humidifier bottle14090510 Nasal cannula with 2.1 m hose14111221 Filter Set

Fuse switch

Hose connection

Flow adjustment knob lockable

Page 62: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

60

nUVO 8Art. Nr. Description14111811 Concentrator Nuvo 8 teChniCAL DAtA Operating voltage: 230 Volt – 50/60 HzFlow rate: 0.5 to 8 l/min.O2 concentration: 0.5 to 7 l/min. - 93% (+6.5% / -3%) At 8 l/min. - 90% (+6.5% / -3%)Power consumption: 650 wattsOperating pressure: 1.17 bar or 17 psig ± 10%Max working pressure adjustable: 2.75 bar pressure relief valveSecurity Alarm & Features: with energy problems in process errors is too high and too low Low pressure oxygen concentration when too high and too low voltage Overheating protection switchFilters: Backfilter, main filter and antibacterial filterBattery for alarm horn: 9 VoltWeight: < 23 kgDimensions: 394 mm long 396 mm wide 706 mm highEnvironmental conditions: Room temperature: 10 °C to 40 °C Humidity: 15% to 95%Storage conditions: Temperature: -20 °C to 60 °C Humidity: 15% to 95%CE marking: CE 0413

Page 63: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

61

pOrTAbLE OXYGEn COnCEnTrATOr

InOGEn OnE®G2the ADvAntAGes• small • light • compact

inDePenDenCe Whether at home or on the road, through the Inogen One G2 they get the independence they have missed, not only for small errands or short trips, they get real independence. You can now take your time without having to constantly look at the clock and think as long as the oxygen is still.

the POrtABLe OxyGen COnCentrAtOr The G2 system includes the concentrator, carrying case, Combo Adapter 12V/240V, a 4-hour battery (12 cell), a nasal can-nula and a transport caddy.

Page 64: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

62

teChniCAL DAtA Size: 27,4×10,1×24,1cmWeight: 3.2 kgOperating noise: <38 dBA12 Cell Battery: 4 hr/2 hr24 Cell Battery: 8 hr/4 hrProduced oxygen: 900 ml/minAOxygen concentration: 90 +6% /-3%Possible Flow setting: 1-2-3-4-5 liter equivalentAircraft capability: givenSafety: automatic monitoring with acoustic error messageWarranty: 3 years on the device, 1 year batteryCE mark: CE012

InOGEn OnE®G2

Art. Nr. Description14111311 Inogen One ® G2 with 12 Cell Battery System *14111331 Inogen One ® G2 with 24 Cell Battery System *

ACCessOriesArt. Nr. Description14111312 12 Cell Battery 0,454kg14111313 24 Cell Battery 0,907kg14111314 External Battery Charger + Cable14111315 Power supply 12V/240V14111316 Carrying Case14111317 Transport Caddy14111318 Dust filter unit: 2 pcs14111319 240V power cord14111320 12V car cord14111322 Fuse for car cables14111323 Manual14111324 Backpack14111326 2 antibacterial filters with tool14111327 Set of 10 antibacterial filters

12 Cell Akku

24 Cell Akku

* (14111311): nasal cannula + manual + transport caddy + carrying case + 12 cell battery + AC adapter

Netzteil

G2 bATTErY UsEfUL LIfE In HOUrs adjustment 1 2 3 4 512 Cell 4 3:30 2:42 2:12 1:4824 Cell 8 7 5:24 4:24 3:36

Page 65: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

63

COnCEnTrATOr

InOGEn OnE® G3 sYsTEM

The new Inogen One® G3 is a smaller, lighter and makes more oxygen per kg than previous model.

It is a portable concentrator light enough to be worn care-free by the a tive oxygen user.

That means there are no tanks to refill and no worry about running out of oxygen.

Page 66: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

64

Art. Nr. Denomination14111361 Portable Concentrator Inogen One® G3 8 cell battery14111362 Portable Concentrator Inogen One® G3 16 cell battery

ACCessOriesArt. Nr. Denomination14111364 Inogen One® G3 8 cell Battery14111365 Inogen One® G3 16 cell Battery14111366 Inogen One® G3 Ext Battery Charger14111367 Inogen AC Power Supply14111368 Inogen One® G3 DC Power Cable14111369 Inogen One® G3 Carry Bag14111370 Finger Pulse Oximeter

sPAre PArtsArt. Nr. Denomination14111371 Inogen One® G3 Particle Filters14111372 Inogen One® G3 Output Filters qt 1014111373 Inogen One® G3 Filter Spanner Wr14111374 Inogen One® G3 Filter Repl Kit

InOGEn OnE®G3

* Included with system** Accessory sold separately

Double Lithium Ion Battery**Up to 8 hours run time

Single Lithium Ion Battery*Up to 4 hours run time

AC Power Supply*

* At setting 2** See Inogen One® G3 Limited Warranty Statement for complete warranty information

Carry Bag*

COMPArisOn tO inOGen One®G3

teChniCAL DAtAWeight: 2,7 kgSize Length: 22,2 cmWidth: 7,6 cmHeight: 18,4 cmOxygen Flow: Intelligent Delivery Technology Four flow settings 1, 2, 3, 4Power Sensing: AC Power Supply 100-240V, 50-60 Hz (auto sensing to allow worldwide use)DC Power: for mobile use n carBattery Duration: (single battery): 3.5 to 4 hours Recharge approximately 2-4 hours with AC or DC power Duration (double battery): 7 to 8 hours Recharge approximately 4-8 hours with AC or DC powerNoise Level: 42 Decibels*Warranty: 3 year**Operation: Simple control functions and easy-to-read LCD displayUse: Designed for 24/7 use, at home or away

EMErGEnCY EQUIpMEnT

Page 67: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

EMErGEnCY EQUIpMEnT

Page 68: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

66

DEMAnD VALVE

EAsE IIThe New Sabre EASE II portable systems provide a compact low resistance method of self-administering O2 or O2/N20. The EASE demand valve is constructed in a way that creates minimal breathing resistance to the patient and can deliver high flows when required.For greater user comfort the EASE II is both smaller and lighter than the original Sabre EASE. The new ‘Easy Grip’ handle is ano-ther user friendly addition.•On demand Oxygen or Nitrous Oxide/Oxygen system for

delivering up to 300 l/min•Portable first stage regulator and cylinder version for

immediate care and pre-hospital applications.•Low pressure pipeline version for obstetrics and general

nursing applications.•Conforms to BS 4272: Part 2: 1996•Low inspiratory effort demand valve•Test/ Purge facility on the demand valve, easy to clean and

reassemble for cross infection protocol•Hose fitted with probes by the national standards for

connection into cylinder system or wall outlet•Autoclavable, removable handle

The EASE II system is available to deliver Nitrous Oxide/Oxygen upon demand. It is available for use as a portable system with first stage regulator, or as a low pressure pipeline version. The EASE is designed to administer effective pain relief within a wide range of medical situations including immediate care, general practice and general nursing obstetrics.Conforming to BS 4272: Part 2:1996, the demand valve is designed to deliver up to 300 litres per minute of gas with minimal inspiratory effort by the patient. This valve also contains a removable patient valve that houses the exhalation flap and anti contamination valve. This can be removed and cleaned before replacement and re-use.

OPtiOnsThe Sabre EASE range of products is structured in a way to allow the user to define their personal requirements of system, cylinder and carry options.

Page 69: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

67

DEMAnD VALVE EAsE II O2 1.5 M wH DIn120

• for O2 • Hose 1.5 m white • 120° Angled DIN connector • Includes mouthpiece

DEMAnD VALVE EAsE II O2 1.5 M bL DIn 120

• for O2 • Hose 1.5 m black • 120° Angled DIN connector • Includes mouthpiece

DEMAnD VALVE EAsE II O2 1.5 M sp wH DIn 120

• for O2 • White spiral hose 1,5 m • 120° Angled DIN connector • Includes mouthpiece

DEMAnD VALVE EAsE II O2 1.5 M sp bL DIn 120

• for O2 • Black spiral hose 1,5 m • 120° Angled DIN connector • Includes mouthpiece

DEMAnD VALVE EAsE II O2/n220 ss 3M wH / bLUE

• for O2/N2O mixture (ENTONOX™) • Hose 3m white blue for gas mixture O2/N2O • NORDIC Sweden plug to standard norm • including respiratory mask

Page 70: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

68

DEMAnD VALVE EAsE II O2/n2O nf 3M wH / bLUE

• for O2/N2O mixture (ENTONOX™) • Hose 3m white blue for gas mixture O2/N2O • Plug according to French standard AFNOR • including respiratory mask

prEssUrE rEGULATOr MEDIrEG II O2/n2O rEn pI

• Working pressure 4.5 bar • Flow outlet DIN QC • For O2/N2O gas mixture • Flow (l/min)>100

MEDIrEG O2D DQC sMALL

• Working pressure 4 bar • Flow outlet DIN quick coupling

Art. Nr. Type of gas Description Mouthpiece / mask0715311 O2 EASEII O2 1,5M WH DIN120 Mouthpiece0715312 O2 EASEII O2 1,5M BL DIN 120 Mouthpiece0715313 O2 EASEII O2 1,5M SP WH DIN120 Mouthpiece0715314 O2 EASEII O2 1,5M SP BL DIN120 Mouthpiece0715306 O2/N2O EASEII O2/N20 SS 3M wh/blue mask0715315 O2/N2O EASEII O2/N2O NF 3M wh/blue mask0724169 O2/N2O MediReg II O2/N2O REN PI0724142 O2 Medireg O2D, DQC KL

0724142

Page 71: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

69

ventiLAtiOn ADAPter The vent adapter can be placed if required to Ease II demand valve for venting of gases with the use of O2/N2O.

BreAthinG FiLter With 22 mm universal connector, bacteria filtration: 99.999%.

Page 72: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

70

DEMAnD VALVEs - EAsE II

Art. Nr. Gas Type Group Co. Ease II Variant Description0715306 O2/N20 SE EASE II, 3 m hose, SS probe0715310 O2 SE EASE II, 3 m hose, SS probe

teChniCAL DAtA DEMAnD VALVEGas: N2O/O2, O2

Material: Polycarbonate, silicone rubber, stainless steelDimensiones: 50 × 50 × 63 mmWeight: 0,085 kgGas supply: Requirement 2,8 to 7,0 bar at >200 l/minInspiratory resistance(At 2,8 bar supply press.): Cracking 0,15-0,2 kPa -0,2 kPa at 10 l/min -0,7 kPa at 200 l/minExpiratory resistance: Cracking Zero At flow +0,35 kPa at 120 l/minOperating temperature: -20°C tp +60°C used Oxygen +5°C to +40°C used 50/50 N2O/O2

Storage temperature: -30°C to +60°C

HOsE AssEMbLYConnection: Probes by the national standardsWorking pressure: 7 barBurst pressure: 44 barMaterial: PVC, anti-static in accordance with ISO 5359Weight: 0,5 kg (3 m length)Manufacturer: GCE, s.r.o, Žižkova 381 583 81 Chotebor, CZ

ACCessOries tO eAse iiArt. Nr. Description1024103 Case boxed c/w strap and frame1032937 Disposable mouthpiece (pack of 5 pcs)1035575P Breathing filter (pack of 5 pcs)1032994P Disposable facemask - medium (pack of 5 pcs)1032620P Adult size reusable mask1032624P Child size reusable mask1023364 Thermometer for N2O/O2 cylinders1024417 Blue barrel carry bag 1032622P Adult/Child size mask, multiple use for Ease II 850500P Expiration diverter single use for Ease II (pack of 1 pce)

Page 73: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

71

bAG VALVE MAsKs

COMPACt resusCitAtOr with MAsK extensiOn tuBe, FOr eMerGenCy resPirAtiOn Made from silicon rubber and autoclavable up to 136°C. Supplied with mask, oxygen reservoir, oxygen tube and mask extension tube.

Art. Nr. Description325113013 Bag Valve Mask kit

teChniCAL DAtA

Code: 01Size: AdultBellow Capacity: 1500 mlOxygen Reservoir Capacity: 2600 mlFace Mask: Size # 4 and 5Mask Extension Tube: 300 mm

MATErIAL Bellow: Silicon Rubber Extension Tube: Silicon RubberMasks: 4 & 5 Polycarbonate and Silicon RubberNon-Return Valve: PolycarbonateDiaphragm: Silicon RubberReservoir Valve: PolycarbonateReservoir Diaphragm: Silicon RubberOxygen Reservoir Bag: PVC* Oxygen Tube & Adaptor: PVC* (Tube Length 2 meters).

*Polyvinyl Chloride Note: Product is Latex free.

Guedele Airways are designed to maintain an unobstructed oropharyngeal airway during or following general anaesthesia and in patients who are unconscious for other reasons.

• Integral hard bite block avoids airway occlusion and biting of tongue.•Stepless airway path for easy cleaning.•Bite blocks are colour coded for instant identification of sizes.

Each kit contains 2 pieces each of sizes 2, 3 & 4.

•Manufactured from non-toxic, non-irritant polymer PE.• Individually packed in peelable soft blister pack.•Sterile ready for use.

MAsKs

Art. No. Denomination 1032622P Child silicone mask with multi-function mask cover1032620P Adult silicone mask with multi-function mask cover

teChniCAL DAtA Material: Mask: Silicone (Si) Multi-Function Mask Cover: Polysulfone(PSU) Head Strap: PolyVinylChloride (PVC) Attachment Ring: Polysulfone (PSU)Operating Environmental Conditions: -18 °C to 60 °C 15% to 95% relative humidityStorage Environmental Conditions : -40 °C to 70 °C 40% to 95% relative humidity Patient port on mask fit standard 15/22 mm connectorsProduct is in compliance with essential requirements of council directive 93/42 EEC Medical Device Directive

b)

d)

c)

a)

a) mask, b) oxygen reservoir, c) oxygen tube,d) mask extension tube

Page 74: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

72

Manual switch-over

Gauge

Quick Couplings

Outlet

AMbULAnCE pAnEL

AMbULAnCE pAnEL IIThe Ambulance Panel II is the next generation of ambulance panels. It is designed for permanent installa-tion and use in road ambulances. Long experience in this market has resulted in a product that gives the customer a lot of options and flexibility.

FLexiBiLityDue to the design and functions there are a big range of variants available. The functions and variants can be combined upon customer’s request.

MODuLArThe modular concept means that same components can be used for many variants, resulting in short lead times and full flexibility. The Ambulance Panel II is designed with same shape for recessed and exposed.

Page 75: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

73

reCesseDRecessed mounting is when the ambulance panel is mounted in the wall. The inlet could either be mounted at the end or at the back depending on the wall construction and the space behind the wall. The only part that will be outside the wall is the quick connector.

exPOseDExposed mounting is when the ambulance panel is mounted on the wall in the ambulance. The inlet could as the recessed, also be located at the end or at the back. When using the end inlet the hoses are fastened on the wall and fully visible. For some countries and regulations this is a must and the Ambulance Panel II has the features comply-ing to these requests. The panel is fastened easily by 4 screws. Depending on the wall construction the fastening could either be done by a counter fastening frame or nuts and washers.

inLetThe inlet connection the the Ambulance Panel II is standard 3/8 thread. This is a standard thread with conical sealing that has been used many times in this kind of application. Using a threaded connection gives the assembly easier and the parts easy to maintain and exchange.

quiCK COuPLinGsThere are many variants of quick couplings on the Ambulance Panel II. The most frequent standards are used on the Ambulance Panel II. For special quick couplings please contact GCE. By using standard components and quick couplings the assembly is easy and the maintenance access able and effective.

OutLetThe outlet is standard 3/8 thread connection. If additional panels are needed, the Ambulance Panel II can have extra outlets for panels mounted in series. The panels are then connected with a standard hose and hose connec-tions.

MAnuAL switCh-OverThe manual switch-over is a selector that chooses what cylinder is supplying the ambulance panel. There are three steps 1-0-2, where the 0 is off 1 is cylinder one and 2 cylinder two. The manual switch-over can be incorporated in the panel beside the other quick couplings or it could be mounted separately.

AMbULAnCE GAs pAnEL II

Recessed

Exposed

Inlet

Quick Couplings

Outlet

Sketch of double recessed mounted panelSketch of recessed mounted panelSketch of expossed mounted panel

Manual switch-over

Art. Nr. Description Number Gas Flow Surface, Inlet Outlet Hose of head Flush, connector connector supplied control deep elements Flush* 0715401 Ambulance Panel 4× DQC 4 O2 no UP* 3/8" no no0715402 Ambulance Panel 3× DQC 3 O2 no UP* 3/8" no no0715403 Ambulance Panel 2× DQC 2 O2 no UP* 3/8" no no0715404 Ambulance Panel 1× DQC 1 O2 no UP* 3/8" no no0715405 Ambulance Panel 1× DQC 1 AIR no UP* 3/8" no no0715406 Ambulance Panel 3× DQC 3 O2 no UP* 3/8" no no +Manometer

Flexi Units 0715416 Flexi Unit 25 O2+ MS32 2 O2 1×25l. AP* 3/8" 3/8" no0715425 Flexi Unit 25 O2 2× 2 O2 1×25l. AP* 3/8" 3/8" no0715424 Flexi Unit 15 O2 5× 5 O2 5×15l. AP* 3/8" 3/8" 1,5 m bl 0715410 Flexi Unit 25 O2 1× 1 O2 1×25l. AP* 3/8" 3/8" no0715418 Flexi Unit 25 O2 1× 1 O2 1×25l. AP* 3/8" 3/8" no

Switch 0715410 Switch H-O 1 O2 no UP* 1/8"i 1/8"i no0727205 Switch GSS 1 O2 no UP/AP* no Regulators on request Pressure regulator 1 O2 no 3/4" 1/4" no with contact gauge 0724118 Medireg 100 O2, DQC 1 O2 no 3/4" DIN QC no0724141 Medireg 100 O2D, KL3-8 1 O2 no 3/4" 3/8" no

Page 76: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

74

GAuGeOne of the additional functions in the Ambulance Panel II is the gauge on the panel. The gauge is showing the working pressure in the system and gives continuously surveillance and is fully visible by the staff in the ambulan-ce.

FLOwseLeCtOrThe AP II module can be equipped with a flow selector. The flow selector is permanently attached to the AP II module and can be delivered with the flow settings 0-15 and 0-25 liter per minute. This integrated module gives the AP II a compact design and minimize the products sticking out from the wall.

suCtiOnThe integrated suction ejector is a variant in the AP II system giving the end user a complete range of functions. The suction ejector uses the pressure in the system to create suction by the venture principle. The unit is operated by a simple on of button and a regulating knob to adjust the negative pressure.

AMBuLAnCe PAneL systeM (APs)The complete installation of the ambulance panel, hoses and regulators is called Ambulance Panel System.

teChniCAL DAtA Weight: example AP II O2 2×SS R: 754gQC standards: SSGases: O2

Standards: EN 1789:2008Classification: Class IIb

Flowselector

Suction

DiMensiOns:rECCEsED MOUnTInG

441

428

79 66

28 55 70 6855

22.5

EXpOsED MOUnTInG441

7966

428

427

60.9

29

68 55 70 55 28

Gauge

Note! Measurements in mm.

Page 77: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

75

AMbULAnCE pAnEL II 3 × DQC + MAnOMETEr

Unterputz Ausführung, UP. Abbildung mit eingesteckten Geräten, nicht im Lieferumfang enthalten. (Von links nach rechts: MediMeter, O2 Schlauch mit DIN Stecker, Flowregler MediFlow Ultra)

AMbULAnCE pAnEL II 1 × DQC

Unterputz Ausführung, UP. Eingangsanschluss 3/8“ mit Schlauchtülle

fLEXfI UnIT 25 O2 1 ×

Aufputz Ausführung, AP. Eingangsanschluss 3/8“ mit Schlauchtülle. Ausgangsanschluss 3/8“ mit Schlauchtülle.

teChnisChe DAtenSchnellkupplungen: DIN, SS = Skandinavisch, NF= Französisch, BS = England Gase: O2, AIR, Erfüllte Normen: EN1789 : 2008Medizinprodukt Klasse: 2bHersteller: GCE sro, Zizkova 381, 58381 Chotebor, CZCE Kennzeichnung: CE0434

Page 78: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

76

AMbULAnCE rEGULATOrs

MEDIrEG® II VArIMED

The Ambulance regulators are regulators specifically for use in road ambulances. GCE has long experience with re-gulators and ambulance oxygen supply systems, and this has resulted in a new range of ambulance regulators, and to meet the requirements on the market.

MeDireG® ii with eLeCtrOniC siGnAL GAuGeThe Medireg is a new developed regulator in the GCE group. GCE has now adapted the Medireg with a signal gauge suita-ble for road ambulances. The Medireg with electronic gauge is suitable for ambulances with low to medium capacity needs. The Medireg together with the new ambulance panel products, GCE can offer a complete system for ambulance builders and ambulance services.

vAriMeD with eLeCtrOniC siGnAL GAuGeThe Varimed is the regulator suitable for road ambulances with medium to high capacity needs. The Varimed regulator is a product well established on the market. Together with the new concept of integrating the electronic gauge, GCE offers a range well suitable for the ambulance market.

Page 79: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

77

AMbULAnCE rEGULATOrs

MEDIrEG® II wITH ELECTrOnIC sIGnAL GAUGE

teChniCAL DAtA Gas: O2

Inlet pressure range: up to 200 barNominal outlet pressure: 4 barInlet connection: according to national standardsOutlet connection: according to national standards or specificationBody material: nickel-plated brassO-rings: EPDMFilter: sintered bronzeRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN 10524-1 (Pressure regulators for use with medical gases) Complies with Standard EN 1789:2000 (Medical vehicles and their equipment - Road ambulances)Classification: Class IIb

VArIMED wITH ELECTrOnIC sIGnAL GAUGE

Art. Nr. Denomination0783832 Varimed O2

G 1/4

W21

,7x1

4

Ø55

98.5 78

66

WIKA

W21

.8x14

106

172

106

Ø55

FLOw Curve FOr OxyGen (P2 = 4 BAr)

Page 80: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

78

GAUGE wITH ELECTrICAL OUTpUT sIGnAL (sAME fOr MEDIrEG® II AnD VArIMED)

teChniCAL DAtA Design: Bourdon Tube EN 837-1Nominal size: 50 mmAccuracy class: 2.5Scale ranges: 0 -300 barOperating temperature: Ambient: -20 ... +60 °CMedium: +90 °C maximumTemperature effect: When temperature of the measuring system deviates from referencetemperature (+20 °C): max. ±0.4 %/10 K of the spanPressure element: Cu-alloy, C-typeMovement: Cu-alloyDial: Plastic white, black letteringPointer: Plastic, blackCase: Stainless steelWindow: Plastic, clear (PC)Ingress protection: IP 65 per EN 60 529 / lEC 529

ELECTrOnICs Output signals: (275° indication angle) 0.5 ... 4.5 V, VS = 12 ... 32 V DC 4 ... 20 mA, 2-wire, VS = 12 ... 32 V DCSupply voltage (Vs): 5 V DC / 12 ... 32 V DCElectromagnetic compatibility: According to test standards EN 61000-4-6 / EN 61000-4-3

Page 81: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

79

Gss

The Automatic Gas Source Switch has been developed for devices such as transport incubators, respirators and anaesthesia devices, which can be sup-plied with gas from a cylinder during transport or whilst stationary connected to a central gas system. Economic and continuous gas supply from the central gas system will be made possible automatically and the safety of patients increased.

Key BeneFits• Increased safety for users and patients•Economic gas supply from wall outlet•Less frequent replacement of gas cylinders•Compact dimensions•Simple connection to devices•A green pressure indicator indicating gas supply from gas outlet

Art. Nr. Type0727205 GSS 02 NIST0727206 GSS AIR NIST

teChniCAL DAtAGases: O2, AIR, N20 on requestInput pressure at gas outlet: 3-6 barInput pressure of pressure reducer: 3.6 – 5.5 barOutput pressure: = input pressureOutput flow (no internal reduction): = input flowHousing material: Al-alloy, nickel platedDimensions: 42×65×74 mmWeight: approx. 400 gMaintenance: maintenance freeMax. life: 10 yearsSuitable for use: in emergency in transport

Gss InLET-HOsE ATTACHMEnT From gas outlet connection: NIST or AfnorFrom pressure reducer: M12×1 (O2) M20×1 (AIR)

Gss-OUTLET HOsE ATTACHMEnT To consumer: M15×1 (O2) M17×1 (AIR)

GSS automatic gas source switch switches automatically between the gas cylinder supply and wall outlet connec-tion. Preference is always given to the more economic wall outlets. As soon as the gas socket is connected, GSS changes over from the wall cylinder to the gas outlet. It does not change over to the gas cylinder unless the pressure at the wall outlet drops below a preset minimum pressure level.

FLOw sCheMe

hOsesArt. Nr. Denomination0731049 Hose O2 white 0,5 m SS/M12×10731050 Hose O2 white 1,5 m SS/NIST0731051 Hose O2 white 0,5 m SS/M15×1

GSS on transport incubator

GSS on transport respirator

WALL OUTLET

DEVICEDEVICE

Page 82: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

80

MULTIsTAr

FLOwseLeCtOrs On BLOCKArt. Nr. Denomination0728196 Multistar 50728195 Multistar 4

teChniCAL DAtA Calibration pressure: 4.5 barFlow: 0-15 litres/minute/flowmeterConnection: Oxygen quick coupling SS

0728196 Block with five flowselectors

0728195 Block with four flowselectors

HOspITAL CEnTrAL GAs sUppLY sYsTEM

Page 83: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

HOspITAL CEnTrAL GAs sUppLY sYsTEM

Page 84: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

82

MEDICAL CEnTrAL GAs sUppLY sYsTEMsMM40 - Hp UnIT sEMIAUTO

Manifolds systems are providing the source of the medical gases in hospitals. Main function is reducing pressure from high pressure cylinders to the pressure level which is possible to use in the hospital pipe line. Manifolds have to fulfill the strict requirements of the medical installation standards and of course safety of all patients in the hospital.

GCE helps the installers to fulfills ISO 7396 and national installation standards with secure products where testing protocol guarantee great production testing. Our range is covering complete solutions of manifolds installations from high pressure manifolds to stabilizers, all in accordance with European legislation.

Key BeneFits•Very stable outlet pressure irregularity coefficient 20× better than standard•40 m3/h is lowest flow•Manifold dimensions are minimized•Service without interrupt the flow

Art. Nr. Denomination Gas Inlet connection Outlet connection0727330 MM40 – HP unit 2×1 O2, AIR, N2 Standard C440727335 MM40 – HP unit 2×1 N2O, CO2 Standard C440727331 MM40 – HP unit 2×1 O2, AIR, N2 Manual activation C440727336 MM40 – HP unit 2×1 N2O, CO2 Manual activation C440727334* MM40 – HP unit 2×1 O2, AIR, N2, N2O, CO2 Standard -

Manifold MM40 Semiauto is semi-automatic manifold. It is working on principal different pressure between operation and reserve regulator. By the manual handle operator can decide which side will be operational one and which reserve one. When operating side is empty manifold without any operation action start supply gas from reserve side with lower pressure value and fulfill requests to supply without interrupt the flow.MM40 Semiauto manifolds should be use as second and third source of gas in connection with liquid gas tank. For hospitals without liquid gases is possible use manifold MM40 Semiauto as first and second source and connecting with MM90 Backup will give you final solution for fulfill ISO 7396-1 and national installation standards.Manifolds is supply with Alarm system which increase safety to maximal level and inform hospital personal about each non standard situation. Gas Alarm C44 is Standard Accessory. The gas alarm C44 gives visual and audible indication.

it surveiLLAnCe AnD sOunDs the ALArM when the FOLLOwinG hAPPens:1. Leaking reserve side2. —3. High operation pressure4. Change operation side

The gas alarm C44 is able to communicate with other equipment through relays.The alarm has a battery back-up for 30 minutes of operation.Manifold MM40 Semiauto is only first stage of regulation and must be install together with Stabilizer which will stabilize the pressure on final pressure use in hospital gas outlets.GCE medical manifolds are CE marked and fulfill ISO 7396-1 standard.

sPeCiFiCAtiOnMM40 InCLUDEs THE fOLLOwInG COMpOnEnTs:•MM40 SEMIAUTO Manifold •Gas alarm C44 •Purge valves •HP filters

fOr A COMpLETE MM40 sEMIAUTO MAnIfOLD ADD:•Collecting pipe set (high pressure valves, and non-return valves /high pressure components/) •Cylinder retaining brackets•High pressure hoses with safety wire•Plug for close collecting pipeline •Gas name sign

Page 85: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

83

teChniCAL DAtAGases: O2; AIR; N2; N2O; CO2; (all medical gases)Nominal flow: 40m3/hInlet nominal pressure: 200 barOutlet nominal pressure: 11 bar (setting range 10-12 bar)Inlet connection: W21,8×1/14” MOutlet connection: G1/2” M + Soldering piece pipe Ø10, Ø15Safety valve pipe dimension: OD = 10mmPurge valves connection: W21,8×1/14”MRegulatory status: Complies with Medical directive 93/42/EEC Complies with EN ISO 7396-1 (Central Gas Supply system) Complies with EN 60601-1 (Electric safety) Complies with EN 60601-1-2 (Electromagnetic compatibility)

FLOw ChArt OF MAniFOLD MM40 Pressure ChArACteristiC

Note! Measurements in mm.

Page 86: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

84

HOspITAL CEnTrAL GAs sUppLY sYsTEMGAs MAnIfOLD MM90 AUTOMATIC

The MM90 automatic medical manifold is intended for use in hospital pipeline system as medical gas source. Together with MM90, there shall always be used an alarm providing all alarms according to standard (like Gas alarm C44). As 2nd stage is recommended to use a stabilizer.

The manifolds covered by this description are designed to allow equal num-bers of cylinders to be manifold together to give an operating bank and a reserve bank. The manifold will deliver gas from the operating bank to the manifold pressure regulator until the cylinders are exhausted. At that point the supply will switch to the reserve bank and the exhausted bank can be replenished. The object is to give uninterrupted gas supply.

Gas Alarm C44 is standard accessory. The Gas alarm C44 gives visual and audi-ble indication. It surveilles and sounds the alarm when the following happens: 1. Change operation side / Leaking on reserve side2. High operation pressure3. Low operation pressure

The Gas alarm C44 is able to communicate with other equipment through relays. The alarm has a battery back-up for 30 minutes of operation.

Art. Nr. Denomination Gas Inlet connection Outlet connection0727301 MM90 AUTO Manifold O2 W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727302 MM90 AUTO Manifold AIR W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727303 MM90 AUTO Manifold N2O W 21,8×1/14"M G3/4"F+pipe OD 22 mm

sPeCiFiCAtiOnMM90 InCLUDEs THE fOLLOwInG COMpOnEnTs:•MM90 AUTO Manifold•Gas alarm C44•Purge valves

fOr A COMpLETE MM90 AUTO MAnIfOLD ADD:•Collecting pipe set (high pressure valves, and non-return valves /high pressure components/)•Cylinder retaining brackets•High pressure hoses with safety wire•Plug for close collecting pipeline•HP filters•Gas name sign

teChniCAL DAtACapacity at 9 bar (900 kPa) outlet pressure: O2, AIR: 90 m3/h N2O, CO2: 50 m3/hMax. inlet pressure (settled): 20 000 kPa (200 bar)Max. outlet pressure: 1200 kPa (12 bar)Safety + purge valves pipe dimension: OD = 10 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

455

530

760 Note! Measurements in mm.

Page 87: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

85

GAs MAnIfOLD MM90 sEMIAUTOMATIC

The MM90 semiautomatic medical manifold is intended for use in hospital pipeline system as medical gas source. Together with MM90, there shall always be used an alarm providing all alarms according to standard (like Gas alarm C44). As 2nd stage is recommended to use a stabilizer.

The manifolds covered by this description are designed to allow equal numbers of cylinders to be manifold together to give an operating bank and a reserve bank. The manifold will deliver gas from the operating bank to the manifold pressure regulator until the cylinders are exhausted. At that point the supply will switch to the reserve bank and the exhausted bank can be replenished.The object is to give uninterrupted gas supply.

Gas Alarm C44 is standard accessory. The Gas alarm C44 gives visual and audi-ble indication. It surveilles and sounds the alarm when the following happens: 1. Change operation side2. Leakage on reserve side3. High operation pressure4. Low operation pressure.

The Gas alarm C44 is able to communicate with other equipment through relays. The alarm has a battery back-up for 30 minutes of operation.

Art. Nr. Denomination Gas Inlet connection Outlet connection0727304 MM90 SEMIAUTO Manifold O2 W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727305 MM90 SEMIAUTO Manifold AIR W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727306 MM90 SEMIAUTO Manifold N2O W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727313* MM90 SEMIAUTO Manifold O2/AIR W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727314* MM90 SEMIAUTO Manifold N2O/CO2 W 21,8×1/14"M G3/4"F+pipe OD 22 mm

*with Gas alarm MC7701, safety valve according to SISHB370

sPeCiFiCAtiOnMM90 InCLUDEs THE fOLLOwInG COMpOnEnTs:•MM90 SEMIAUTO Manifold•Gas alarm C44•Purge valves

fOr A COMpLETE MM90 sEMIAUTO MAnIfOLD ADD:•Collecting pipe set (high pressure valves, and non-return valves /high pressure components/)•Cylinder retaining brackets•High pressure hoses with safety wire•Plug for close collecting pipeline•HP filters•Gas name sign

teChniCAL DAtACapacity at 9 bar (900 kPa) outlet pressure: O2, AIR: 90 m3/h N2O, CO2: 50 m3/hMax. inlet pressure (settled): 20 000 kPa (200 bar)Max. outlet pressure: 1200 kPa (12 bar)Safety + purge valves pipe dimension: OD = 10 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC.

Complies with EN ISO 7396-1 (Central Gas Supply System)

455

530

760Note! Measurements in mm.

Page 88: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

86

GAs MAnIfOLD MM90 sTAnDbY (bACKUp MAnIfOLD)

The manifold MM90 STANDBY covered by this description is designed to be used as a third source of suppply in medical central gas systems. The manifold will deliver gas when the nominal supply system pressure falls below a set level (7 bar). This is a back up source.Together with MM90 STANDBY, there shall always be used the MM90 AUTO or SEMIAUTO, alarm providing all alarms according to standard (like Gas alarm C44). As 2nd stage is recommended to use a stabilizer.Standard Accessory Gas Alarm C44The gas alarm C44 gives visual and audible indication. It surveilles and sounds the alarm when the following happens:

•Too high outlet pressure,

•Too low outlet pressure,

•Empty cylinderThe Gas alarm C44 is able to communicate with other equipment through relays. The alarm has a battery back-up for 30 minutes of operation.

Art. Nr. Denomination Gas Inlet connection Outlet connection0727307 MM90 STANDBY O2, AIR W 21,8x1/14"M G3/4"F+pipe OD 22 mm0727312 MM90 STANDBY N2O, CO2 W 21,8x1/14"M G3/4"F+pipe OD 22 mm

sPeCiFiCAtiOnMM90 InCLUDEs THE fOLLOwInG COMpOnEnTs:•MM90 STANDBY Manifold with pressure switch•Purge valves

fOr A COMpLETE MM90 sTAnDbY MAnIfOLD ADD:•Gas alarm C44•Collecting pipe set (high pressure valves, and non-return valves /high pressure components/)•Cylinder retaining brackets•High pressure hoses with safety wire•Plug for close collecting pipeline•HP filters•Gas name sign

teChniCAL DAtACapacity at 7 bar (700 kPa) outlet pressure: O2, AIR : 90 m3/h N2O, CO2 : 50 m3/h Max. inlet pressure (settled): 200 bar (20 000 kPa)Max. outlet pressure: 12 bar (1200 kPa)Safety + purge valves pipe dimension: OD = 10 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

245

363

318Note! Measurements in mm.

Page 89: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

87

GAs MAnIfOLD MC80 (DUpLEX)

This gas manifold is suitable for the medium to the large sized hospital. The MC 80 has a flow capacity of up to 80 m3/h and is conveniently designed in modules. The MC 80 reduces the gas pressure in two steps to a constant operating pressure. Service and tests are to be carried out with no disturban-ce in the supply of gas to the gas distrubution system.

the MC 80 (DuPLex) COnsists OF the three FOLLOwinG units:1. MC 80 - HIGH prEssUrE UnIT This module contains two regulators with safety valves and it is connected to two various cylinder banks with high pressure hoses. When the cylinder bank which has been connected for operation, has been emptied, the other duty side is automatically connected.

2. MC 80 - sTAbILIZErThe stabilizer makes the operating pressure in the distribution system remain constant. The module contains two regulators with safety valves. Since the gas pressure is reduced in two steps the drop in pressure, when changing from the operating cylinder to the other bank of cylinders, is kept to a minimum. The unit is prepared for connec-tion to a liquid supply tank.

3. MC 7701 - DIGITAL prEssUrE MOnITOrThis monitor gives visual and audible indication as well as a message in plain language. It electronically surveilles and sounds the alarm when the following happens: 1. Too high or too low distributing pressure,2. Too high intermediate pressure,3. Leakage on the reserve gas cylinder bank,4. When change of operating side has been effected.

When connected to a liquid tank the following disturbances will be reported:1. Too high or too low operating pressure,2. Too high or too low intermediate pressure,3. Leakage from the reserves,4. When change of operating side has been effected.The MC7701 is able to communication with another equipment through a serial link and/or relays. The alarm has a battery back-up for 30 minutes of operation.

sPeCiFiCAtiOnMC 80 (DUpLEX) InCLUDEs THE fOLLOwInG COMpOnEnTs:•MC 80, High Pressure Unit•MC 80, Stabilizer•MC 7701, Digital Pressure Monitor•Evacuating kits for collecting pipe•Shut-off valve for the distribution line•HP filters

fOr A COMpLETE MC 80 (DUpLEX) sTAnDbY MAnIfOLD ADD:•Collecting pipe set (high pressure valves, and non-return valves /high pressure components/)•Cylinder retaining brackets•High pressure hoses with safety wire•Gas name sign

Art. Nr. Denomination Gas Inlet connection Outlet connection0727318 DUPLEX 2×1 O2 W 21,8×1/14"M 2× G3/4"F+pipe OD 22 mm0727319 DUPLEX 2×1 AIR W 21,8×1/14"M 2× G3/4"F+pipe OD 22 mm0727320 DUPLEX 2×1 N2O/CO2 W 21,8×1/14"M 2× G3/4"F+pipe OD 22 mm0727321 MC80 HP 2×1 O2 W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727322 MC80 HP 2×1 AIR W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727323 MC80 HP 2×1 N2O/CO2 W 21,8×1/14"M G3/4"F+pipe OD 22 mm0727324 MC80 STAB O2 3× G3/4"F+pipe OD 22 mm 2× G3/4"F+pipe OD 22 mm0727325 MC80 STAB AIR 3× G3/4"F+pipe OD 22 mm 2× G3/4"F+pipe OD 22 mm0727326 MC80 STAB N2O/CO2 3× G3/4"F+pipe OD 22 mm 2× G3/4"F+pipe OD 22 mm

Page 90: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

88

teChniCAL DAtACapacity at 600 kPa (6 bar) working pressure: O2 : 80 m3/h N2O : 80 m3/hHigh Pressure Unit MC 80: Max. inlet pressure: 200 bar (20 000 kPa) Max outlet pressure: 16 bar (1600 kPa) Safety valves OD = 10 mm Purge valves OD =15 mmStabilizer MC 80: Max. inlet pressure: 16 bar (1600 kPa) Max working pressure: 8 bar (800 kPa) Safety valves OD = 15 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

580

450

580

450

Note! Measurements in mm.

Page 91: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

89

GAs MAnIfOLD MC25

The gas cylinder manifold MC 25 is delivered as standard for the gases medical breathing oxygen, nitrous oxide, medical breathing air, medical carbon dio-xide, and nitrogen. This manifold has a capacity of 25 m3/h and is primarily intended for small and medium-sized hospitals. The gas cylinder pressure is regulated in two steps. The change-over between operating side and reserve side is made automatically without any differences in the operating pressure. Alarm signal comes from the pressure switches to the alarm unit C44. The alarm signals from the alarm unit C44 can be forwarded directly to a monito-ring desk. Function control and service can be carried out without interrup-tion in the gas supply.

sPeCiFiCAtiOnMC 25 InCLUDEs THE fOLLOwInG COMpOnEnTs:•Gas manifold MC 25•Gas alarm C44 (exposed mounting) including power supply•Evacuating kits for collecting pipe•Shut-off valve for distribution line•HP filters

fOr A COMpLETE MC 80 (DUpLEX) sTAnDbY MAnIfOLD ADD:•High pressure collecting pipes, high pressure valves, filters and non-return

valves•High pressure hoses with safety wire•Cylinder retaining brackets•Gas name sign

Art. Nr. Denomination Gas Inlet connection Outlet connection0727315 MC 25 O2 W 21,8×1/14"M G1/2"F + pipe OD10mm+OD15mm0727316 MC 25 AIR W 21,8×1/14"M G1/2"F + pipe OD10mm+OD15mm0727317 MC 25 N2O, CO2 W 21,8×1/14"M G1/2"F + pipe OD10mm+OD15mm

teChniCAL DAtACapacity at 5 bar (500 kPa) operation pressure: and pressure drop 0.5 bar (50 kPa): O2, AIR, N2: 25 m3/h N2O, CO2: 17 m3/hMaximum inlet pressure: 200 bar (20 000 kPa)Maximum operation pressure: 10 bar (1000 kPa)Safety + purge valves pipe dimension: OD = 15 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

485

450

Note! Measurements in mm.

Page 92: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

90

HIGH prEssUrE MAnIfOLD ACCEssOrIEsGCE can supply a complete range of high pressure accessories making it possible to install a medical gas supply system. All accessories are designed and manufactured according to the relevant standard for high pressure systems. The high pressure pipe components are manufactured in the following mate-rials: stainless steel AISI 316 L and brass CuZn39Pb3, and they are tested at 360 bar. Cylinder holders for cylinders and connecting pipes are manufactured in AISI 316.

COLLECTIOn pIpE LInE

Collecting pipe set in prepare for GCE HP manifold units. These sets are increasing inlets points for HP cylinders or bundles. Colecting sets are possible connecting serially therefore select ideal combination.

set COntAints:•High Pressure Valve•Non Return Valve•Collection Pipe

Art. Nr. Denomination0733003 1 cylinder collection pipe set0733004 2 cylinders collection pipe set0733005 4 cylinders collection pipe set0733000 2×1 cylinder collection pipe set0733001 2×2 cylinders collection pipe set0733002 2×4 cylinders collection pipe set0733006 2×1 cylinder collection pipe set+cylinder holders0733007 2×2 cylinders collection pipe set+cylinder holders0733008 2×4 cylinders collection pipe set+cylinder holders

HIGH prEssUrE HOsEs

Medical high pressure hoses are used to connect cylinders or cylinder bundles to gas supply systems. The high pressure hose is intended to be used with a pressure up to maximum 230 bar. Pressure tested at 345 bar. The hose is equ-ipped with a safety wire.

hAnDLinGThe high pressure hose shall be transported, stored, installed and maintained according to Instruction of Use. Maximum life time from installation 5 years.

Art. Nr. Gas Lenght (mm) Inlet connection Outlet connection325197641 O2 1250 W21,8×1/14” RH W21,8×1/14” RH325197651 O2 2000 W21,8×1/14” RH W21,8×1/14” RH325197642 N2O 1250 R3/8”RH W21,8×1/14” RH325197652 N2O 2000 R3/8”RH W21,8×1/14” RH325197643 AIR 1250 R5/8”RH W21,8×1/14” RH325197653 AIR 2000 R5/8”RH W21,8×1/14” RH325197644 N2/Ar 1250 W24,32×1/14” RH W21,8×1/14” RH325197654 N2/Ar 2000 W24,32×1/14” RH W21,8×1/14” RH325197645 CO2 1250 W27×2 RH W21,8×1/14” RH325197655 CO2 2000 W27×2 RH W21,8×1/14” RH

teChniCAL DAtA - MAteriALTube: Acid-proof Stainless Steel (AISI 316)Plait: Stainless Steel (AISI 304)Wire: Stainless Steel (AISI 304)Nut and tightening material: Acid-proof Stainless Steel (AISI 316)Case and Oetiker: Stainless Steel (AISI 304)Regulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System) Complies with EN ISO 21969 (High Pressure Flexible Connection)

Page 93: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

91

LInE rEGULATOr

The plant regulator reduces the gas pressure from the primary source (cryoge-nic or automatic central tanks) at an adjustable pressure of 3 to 8 Bar. The accuracy of this pressure has a significant effect on gas flow delivered to the patient.That is why a high capacity for instantaneous flow allows an immediate response to hospital needs, while ensuring perfect network Pressure stability.

FeAtures

prEsUrE rEGULATOrOutlet Pressure of 3 to 8 Bar adjustable through the central control pressure. A Safety device control pressure blocks the adjustment control once it is set.

prEssUrE COnTrOLIncludes two gauges for checking inlet and outlet pressure values. The control segments allow easy and immediate reading whether the input and output pressures are correct.

COnnECTIOnsIn case of emergency or power failure in the main network, you can connect to a gas secure network (gas bottle equipped with pressure regulator) through two quick coupler. Complies with AFNOR standard.

sECUrITY CUTTwo valves allows to close the main gas network, if necessary.

teChniCAL DAtADimensions: 160 mm × 200 mm × 80 mmWeight: 1,6 kg rEGULATOr MATErIALBody: AluminumFlap: NitrileValve + ring: Brass + nitrile ACCEsOrIEsGauges: Ø 40 mm (colored segments)Quick Couples: AFNOR standard depending on the gasInlet pressure: 40 BarOutlet pressure: 3,5 a 8 BarOperating temperature: de 20°C a +40°CNominal flow: 40 Nm3/hConnections: Inlet and outlet pipe for 12 mm Welding

Page 94: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

92

MM40 sTAbILIZEr

Manifold MM40 - STABILIZER is secondary gas reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. MM40 - STABILIZER is only secondary reduction unit where the primary gas supply is provided by high pressure gas manifolds (such as MM90, MM40), possibly by the cryogenic tank (LOX). In case of signal for pressure deviation in relation to the alarm settings, the alarm can easily be displayed on a Gas alarm unit. It is also possible to send information to the central operation control. The stabilizer can be delive-red with either pressure transmitter 4-20 mA, pressure transmitter 0-50 mV or with pressure switches. Gas reduction unit MM40 - STABILIZER must be always installed in compliance with the standards EN ISO 7396-1, EN60601-1 and the appropriate national standards.

Key BeneFits•40 m3/h is lowest flow•Manifold dimensions are minimized•Service without interrupt the flow• Inlet for LOX or 3rd source•Special outlet for sensors and QC

teChniCAL DAtA teChniCAL DAtAGases: O2; N2O; Air; Air-800 CO2; N2

(all medical gases)Nominal flow: 40 m3/hInlet maximal pressure: 16 barOutlet pressure range: 0,5 - 10 bar (preset to 4,5 bar)Inlet connection 1: G1/2” M + Soldering piece pipe Ø12Inlet connection 2: Optional (G1/2” M + Soldering piece pipe Ø12)Outlet connection: G1/2” M + Soldering piece pipe Ø12Safety valve: Optional (outlet pipe OD = 15mm)Pressure sensors: Optional (Pressure switches; Transmitters 0 – 50mV; 4 – 20 mA)Emergency QC inlet: Optional QC by national standardsRegulatory status: Complies with Medical directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply system). Complies with EN 60601-1 (Electric safety). Complies with EN 60601-1-2 (Electromagnetic compatibility).

BAsiC DiMensiOns

Note!Measurements in mm.

230

110

290

Page 95: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

93

sTAbILIZEr MM7762 fOr O2, n2O, AIr

A stabilizer is a pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. In case of signal for pressure deviation in relation to the alarm settings, the alarm can easily be displayed on a Gas alarm unit. It is also possible to send information to the central operation control. The stabili-zer can be delivered with either pressure transmitter 4-20 mA, pressure trans-mitter 0-50 mV or with contact gauge.The stabilizer makes it possible to distribute gas with different pressure to department and buildings in the hospital area. In some cases it is needed to deliver a higher pressure from the main gas manifold to compensate for small pipe dimensions. In those cases the Stabilizer shall be mounted as close as possible before the first terminal unit, to ensure a correct pressure to the patient.

Art. Nr. Denomination Inlet connection Outlet connection325397762 MM7762 Stabilizer contact gauge 2× G3/4"F+pipe OD 22 mm 2× G3/4"F+pipe OD 22 mm 325397772 MM7762 Stabilizer 4-20 mA 2× G3/4"F+pipe OD 22 mm 2× G3/4"F+pipe OD 22 mm

teChniCAL DAtAMax inlet pressure: 16 bar (1600 kPa)Max operating pressure: 10 bar (1000 kPa)Capacity of 500 kPa (5 bar) operating pressure: 80 m3/hSafety valves pipe dimension: OD=15 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

580

450

Note! Measurements in mm.

Page 96: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

94

sTAbILIZEr MC150 fOr O2, n2O, AIr

A stabilizer is a pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. In case of signal for pressure deviation in relation to the alarm settings, the alarm can easily be displayed on a Gas alarm unit. It is also possible to send infor-mation to the central operation control. The stabilizer can be delivered with either pressure transmitter 4-20 mA, pressure transmitter 0-50 mV or with contact gauge.The stabilizer makes it possible to distribute gas with different pressure to department and buildings in the hospi-tal area. In some cases it is needed to deliver a higher pressure from the main gas manifold to compensate for small pipe dimensions. In those cases the Stabilizer shall be mounted as close as possible before the first terminal unit, to ensure a correct pressure to the patient.

Art. Nr. Denomination Inlet connection Outlet connection325397706 MC 150 Stabilizer contact gauge 2× G1 1/2"F+pipe OD 35 mm 2× G1 1/2"F+pipe OD 35 mm 325397707 MC 150 Stabilizer 4-20 mA 2× G1 1/2"F+pipe OD 35 mm 2× G1 1/2"F+pipe OD 35 mm

teChniCAL DAtAMax inlet pressure: 16 bar (1600 kPa)Max operating pressure: 10 bar (1000 kPa)Capacity of 500 kPa (5 bar) operating pressure: 150 m3/hSafety valves pipe dimension: OD=35 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

830

600

Note! Measurements in mm.

Page 97: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

95

GAs MAnIfOLD sIMpLEX MMr

The Simplex MMR gas manifold is suitable for such health care where the capacity requirement is limited, such as laboratories and small health care cli-nics Veterinary etc. This gas manifold consists of only one group of cylinders.The regulator is mounted in the collection unit. Each inlet connection has a filter, a non-return valve and a shut-off valve. This arrangement makes it possi-ble to use one cylinder at a time.In order to obtain a stabile outlet pressure this gas manifold is equipped with a preset two-stage regulator. On the high pressure side of the regulator there is a contact gauge the signal of which can be carried further to an alarm unit. Simplex MMR is delivered mounted and test-pressurized.

sPeCiFiCAtiOnsIMpLEX MMr IInCLUDEs THE fOLLOwInG COMpOnEnTs:•Gas cylinder manifold Simplex MMR•Collecting pipe Manyflow block for three hoses•Gas evacuation kits for collecting pipe

fOr A COMpLETE sIMpLEX MMr ADD:•Safety valves•Gas alarm C44•High pressure hoses with safety wire•Cylinder retaining brackets•Gas name signs

Art. Nr. Denomination Gas Inlet connection Outlet connection325397702 Simplex MMR O2, AIR, N2, Ar, N2O, CO2 W 21,8×1/14"M G3/8"M

teChniCAL DAtACapacity at working pressure 5 bar: O2, AIR : 30 m3/h N2O, CO2 : 25 m3/hMax. inlet pressure: 200 bar (20000 kPa)Max. outlet pressure: 5 bar (500 kPa)Regulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

520

340

Note! Measurements in mm.

Page 98: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

96

MEDICAL sHUT Off VALVEs

To meet safety requirements, the gas supply to operating rooms etc must be fitted with a device to allow instant shut off. To allow maintenance the gas supply must be controlled by section. To achieve the demands of safety and maintenance, shut-off valves should be fitted in every main line, riser and branch line in the pipework system.The valves are degreased and blown clean. They can be equipped with unions to be soldered to the copper piping and they are provided with name labels in Swedish, Norwegian, Danish, Finnish, and Hungarian for each gas type.Before delivery each valve is individually leak tested. The ball is sealed with washer of PTFE. The stem is sealed with two silicon O-rings and PTFE on washer. The housing valves are sealed with an EPDM quality O-ring.

shut-OFF vALve inCL 2 PCs wAsherArt. Nr. Conn. thread Valve L (mm) H(mm) 325196767 ISO-G 1/2 DN 10 67 46325196768 ISO-G 3/4 DN 15 77 48325197794 ISO-G 1 DN 20 100 52325196770 ISO-G 1 1/4 DN 25 115 54 325397236 ISO-G 1 1/2 DN 32 132 72 325397237 ISO-G 2 DN 40 145 84

COnneCtiOn PArts (2 COnneCtiOn nuts AnD 2 COnneCtiOne PieCs)Art. Nr. Material Valve A/B* mm325196910 Red brass SS 5204 DN 10 10 / 15*325196911 Red brass SS 5204 DN 10 12325196912 Red brass SS 5204 DN 15 15 / 22*325196913 Red brass SS 5204 DN 15 18325197795 Red brass SS 5204 DN 20 22 / 28 *325196914 Red brass SS 5204 DN 25 22 / 35 *325196915 Red brass SS 5204 DN 25 28325197324 Red brass SS 5204 DN 32 35/42 *325197325P Red brass SS 5204 DN 40 42

COnneCtiOn PArts (sOLDerinG ADAPter Dn40-Dn50)Art. Nr. Material Valve A/B mm325196776 Red brass SS 5204 DN 50 48/54

Order both DN 40 and DN 50 for union enlargement.

sPAre PArtsArt. Nr. Denomination Valve Thread 325196777P Labelsheet DN 10, 15, 25, 32, 40 - 325110373P Washer, 1 pce DN 10 - 325100729P Washer, 10 pcs DN 15 - 325113389P Washer, 1 pce DN 20 - 325100730P Washer, 10 pcs DN 25 - 201241192P O-ring, EPDM, 5 pcs DN 32 - 201241193P O-ring, EPDM, 5 pcs DN 40 - 202502266 Connection nut, 2 pcs DN 10 ISO-G 1/2 202502268 Connection nut, 2 pcs DN 15 ISO-G 3/4 325113373P Connection nut, 2 pcs DN 20 ISO-G 1 202502270 Connection nut, 2 pcs DN 25 ISO-G 1 1/4 325112281P Connection nut, 1 pce DN 40 ISO-G 2

teChniCAL DAtAMaterial valve housing: Nickel plated brassBall: Chrome plated brassStem: Nickel plated brassMax working pressure: 33 bar (3300 kPa)Tighten proof: 50 bar (5000 kPa)Regulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

•Shut-off valves for oxygen, air for breathing, nitrous oxide and all other medical gases. The shut-off valves are of the ball type with a straight cylindrical bore.

•Easy to operate - 90° turn between fully open and fully closed.

•No maintenance - the ball valve does not need services, when necessary the whole valve is exchanged.

•Unions for brazing and flat sealing connections.

•Reliable, easy to fit.

GCE

max. 40 bar

H

L

Page 99: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

97

nOn rETUrn VALVE

The non return valve unit is intended for use in medical central gas systems to secure that gas doesn´t flow back from the equipment and pipes through the central gas system. This is very important for example when technical air is taken from medical air pipes for use in laboratories.

The non return valve unit consists of a non return valve (NRV) with flow direction arrow, lockable medical shut off valves, soldering pieces, nuts and a gasspecific medical quick coupling (QC) for medical breathing air. This design makes the NRV very easy to test. The QC can also be used for checking the pressure, doing leak tests and take gas samples. The NRV unit can also be delivered with QC for instrumental air. Contact the manufacturer for more information.

nOn return vALve unitArt. Nr. Denomination Total Length325397676 Non return valve unit medical breathing air DN15 415 mm325397677 Non return valve unit medical breathing air DN25 505 mm325397678 Non return valve unit medical breathing air DN40 932 mm

seALinG Between nOn return vALve AnD COnneCtinG PieCeArt.Nr. Denomination944610218P DN15 O-ring, 10 pcs 325112713P DN25 Sealing, 10 pcs 325112880P DN40 O-ring, 10 pcs

teChniCAL DAtAOpening pressure: 0.06 bar (6 kPa)Pressure class: PN16 Regulatory status: Degreesing for Oxygen use no CE-marking

Page 100: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

98

EMErGEnCY sHUT-Off VALVE bOX Dn15

For safety and service reasons a central gas system must be equipped with shut-off valves placed so that the gas supply can easily be interrupted. The valves are mounted in a box. The emergency shut-off valve boxes shall be placed so that the gas can be shut off section wise. This means that the boxes should be placed before each ward, operating unit, part of ward for critical treatment and individual surgeries.

The emergency shut-off valve box is delivered with connection tubes and each box has been test pressurized and controlled for tightness. The emergency shut-off valve has large ergonomical handles. If mounted in a recessed way, the emergency shut-off valve box fits walls with 70 mm beam. With a 90 mm beam there is extra space (23,5 mm) behind the valve box usable for e.g. fire isolation. All models, also with four or five gases, fit between the beams in a CC-60 wall. The box is gas-tight which prevents gas accumulation inside the wall.

The product is CE-marked according to EN ISO 7396-1 and current SIS HB 370.It is important that the boxes are placed so that they are easily available for authorized personnel. The front door shall be sealed.

In order to avoid mistakes the boxes shall be clearly and distinctly marked with gas sort. A sign showing which section the box serves must be placed in its immediate vicinity.

The valves are open when the handles are in vertical position in line with the printed marking on the plate.

shut-OFF vALve BOx Dn15Art. Nr. Type Inlet pipe Outlet pipe325397721 1 valve DN 15 ø 15 ø 15325397722 2 valves DN 15 ø 15 ø 15325397723 3 valves DN 15 ø 15 ø 15325397724 4 valves DN 15 ø 15 ø 15325397725 5 valves DN 15 ø 15 ø 15

4-5 VALVE BOX FOM ABOVE

EXPOSED MOUNTINGSEEN FROM SIDE

RECESSED MOUNTINGSEEN FROM SIDE

1-3 VALVE BOX FROM ABOVE

Note! Measurements in mm.

Page 101: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

99

EMErGEnCY sHUT-Off VALVE bOX Dn20

shut-OFF vALve BOx Dn20Art. Nr. Type Inlet pipe Outlet pipe0732701 2 valves DN 20 ø 22 ø 220732702 3 valves DN 20 ø 22 ø 22

teChniCAL DAtAGases: O2; N2O; AIR;AIR-800(I-AIR); CO2; N2; VAC (all medical gases)Number of gases: (ø15×1) 1 to 5 valves (DN15) (ø22×1) 1 to 3 valves (DN20)Working pressure: 10 barTube dimension: ø15×1 mm; ø22×1 mmMaterial: Brass; CopperWeight: 4 - 15 kgRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

and current SIS HB 370.

2-3 VALVE BOX FROM ABOVEEXPOSED MOUNTINGSEEN FROM SIDE

RECESSED MOUNTINGSEEN FROM SIDE

Note! Measurements in mm.

Page 102: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

100

prEssUrE wATCH wITH GAUGE, ALArM AnD QUICK COUpLInG Dn15

The Pressure Watch has the same shut off function as an ordinary Emergency Shut-Off Valve Box. Behind the plexi-glass you find quick couplings that are used to connect spare cylinders and gauges.

To inform the hospital staff regarding gas failures the Pressure Watch is equipped with sensors for one of the follo-wing alarm systems; 1) – pressure switches that you connect to Gas alarm C44, 2) – pressure transmitters that you connect to Gasalarm MC7701 or 3) – pressure transmitters 4-20 mA that you connect directly to the hospital cen-tral computer system. Alarm system 1 is the most commonly used.

The Pressure Watch is delivered with 300 mm connection tubes and each box has been test pressurized and con-trolled for tightness. The Pressure Watch has large ergonomical handles.If mounted in a recessed way, the emergency shut-off valve box fits walls with 70 mm beam. With a 90 mm beam there is extra space (23,5 mm) behind the valve box usable for e.g. fire isolation. All models, also with four or five gases, fit between the beams in a CC-60 wall. The box is gas-tight which prevents gas accu-mulation inside the wall.

The product is CE-marked according to EN ISO 7396-1 and present SIS HB 370.It is important that the boxes are placed so that they are easily available for authorized personnel. The front door shall be sealed. In order to avoid mistakes the boxes shall be clearly and distinctly marked with gas sort. A sign showing which section the box serves must be placed in its immediate vicinity. The valves are open when the han-dles are in vertical position in line with the printed marking on the plate. To close the valves you turn the handle 90 degrees clockwise.

Pressure wAtCh Dn15 with Pressure switChesArt. Nr. No. of valves Gas Inlet/Outlet pipe mm DN 15325397726 1 O2 ø15325397727 2 O2, Air ø15325397728 3 O2, N2O, Air ø150732824 3 O2, Air, VAC ø15325397729 4 O2, N2O, Air, Air- 800 ø150732825 4 O2,N2O, Air, VAC ø15325397730 5 O2, N2O, Air, Air-800, CO2 ø15

Pressure wAtCh Dn15 with trAnsMitter 4-20 mAArt. Nr. No. of valves Gas Inlet/Outlet pipe mm DN 15 325397861 1 O2 ø15325397862 2 O2, Air ø15325397863 3 O2, N2O, Air ø15325397858 3 O2, Air, VAC red ø15325397864 4 O2, N2O, Air, Air - 800 ø15325397865 5 O2, N2O, Air, Air - 800, CO2 ø15

EXPOSED MOUNTINGSEEN FROM SIDE

1-3 VALVE BOX FROM ABOVE

RECESSED MOUNTINGSEEN FROM SIDE

4-5 VALVE BOX FOM ABOVE

Note! Measurements in mm.

Page 103: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

101

prEssUrE wATCH wITH GAUGE, ALArM AnD QUICK COUpLInG Dn20

Pressure wAtCh Dn20 with Pressure switChesArt. Nr. No. of valves Gas Inlet/Outlet pipe mm0732802 2 O2, AIR ø22 0732804 3 O2, N2O, AIR ø220732803 3 O2, AIR, AIR-800 ø220732805 3 O2, AIR, VAC red ø22

Pressure wAtCh Dn20 with trAnsMitter 4-20 mAArt. Nr. No. of valves Gas Inlet/Outlet pipe mm0732806 2 O2, AIR ø22 0732808 3 O2, N2O, AIR ø220732807 3 O2, AIR, AIR-800 ø220732809 3 O2, AIR, VAC red ø22

Pressure wAtCh Dn20 eMerGenCy sOurCe with Pressure switChesArt. Nr. No. of valves Gas Inlet/Outlet pipe mm0732810 2 O2, AIR ø22 0732812 3 O2, N2O, AIR ø220732811 3 O2, AIR, AIR-800 ø22 0732813 3 O2, AIR, VAC red ø22

Pressure wAtCh Dn20 eMerGenCy sOurCe with trAnsMitter 4-20 mAArt. Nr. No. of valves Gas Inlet/Outlet pipe mm0732814 2 O2, AIR ø22 0732816 3 O2, N2O, AIR ø220732815 3 O2, AIR, AIR-800 ø220732817 3 O2, AIR, VAC red ø22 teChniCAL DAtA

Gases: O2; N2O; AIR; AIR-800 (I-AIR); CO2; N2; VAC (all medical gases)Number of gases: (ø15×1) 1 to 5 valves (DN15); (ø22×1) 1 to 3 valves (DN20)Working pressure: 10 bar (PN16)Tube dimension: ø15×1 mm; ø22×1 mmEmergency QC inlets: QC by national standardsPressure gauges: 0 - 16 barPressure sensors: Pressure switches; Transmitters 0 - 50 mV (special order); 4 - 20 mAMaterial: Brass; CopperWeight: 4 - 15 kgRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

and current SIS HB 370.

2-3 VALVE BOX FOM ABOVE

EXPOSED MOUNTING WITHOUT EMERGENCY SOURCE SEEN FROM SIDE

RECESSED MOUNTING WITH EMERGENCY SOURCE SEEN FROM SIDE

350

296

Note! Measurements in mm.

Page 104: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

102

prEssUrE MOnITOr Dn15

The pressure monitor makes sure that the lower operating pressure for nitro-us oxide compared to oxygen is kept. When the spare supply is used to keep the gas division going, the pressure monitor will supervise the operating pressures to make sure that these are within the established standards. Furthermore, an optic and acoustic signal to a manned area will be obtained. The pressure monitor is equipped with a digital pressure reading unit (MC 7701). The surveillance is done by pressure transmitters. The following gases are under surveillance: breathing oxygen, nitrous oxide, and instrument air. Alarm is indicated by an acoustic and and visual signal at the same time as the exact cause of the alarm is written on the display. This happens if the gas pressure rises above or sinks below the set maximum or minimum limits respectively. The pressure monitor is also equipped with bay-onet coupling for breathing oxygen, nitrous oxide, breathing air, and instru-ment air. When necessary, it is possible to connect spare gas to these.

Art. Nr. Denomination Inlet pipe Outlel pipe ES pipe0732818 For 2 gases O2, Air ø15 ø15 -0732819 For 3 gases O2, N2O, Air ø15 ø15 -0732820 For 4 gases O2, N2O, Air, Air-800 ø15 ø15 -0732821 For 2 gases O2, Air with ES ø15 ø15 ø150732822 For 3 gases O2, N2O, Air with ES ø15 ø15 ø150732823 For 4 gases O2, N2O, Air, Air-800 with ES ø15 ø15 ø15

teChniCAL DAtACapacity emergency supply at 500 kPa (5 bar): and pressure drop 0,5 bar: approx 380 l/minCapacity normal supply at 500 kPa (5 bar): and pressure drop 0,5 bar: approx 780 l/minMax. inlet pressure: 1000 kPa (10 bar)Group regulator capacity at inlet pressure 3 bar: 150 l/minMounting measurements (outside dimensions): Width 549 mm Height 633 mm Depth 128 mmDN15 Pressure monitor: Width 555 mm Height 689 mm Mounting depth max 138 mmRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System)

Pressure drop test. Inlet pressure 5 bar Pressure drop test. Inlet pressure 5 bar. Emergency QC inlets.

Page 105: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

103

GAs ALArM C44 sYsTEM

Gas Alarm C44 is a gas pressure alarm intended for small gas manifolds, stabilizers and for example pressure gau-ges/pressure switches connected directly to the main line. The C44 is a microprocessor based alarm for 4 alarm channels and is connected to the pressure sensing device with volt free contacts, for example pressure gauges or pressure switches. Alarm C44 is voltage fed with 12 VAC. Supply voltage is fed by the enclosed transformer. Visible from the front is an integrated push button TEST/MUTE. If there is no alarm condition, all the light emitting diodes and the buzzer can be tested when the button is pushed.

Should there be an alarm condition, the signal will be suppressed for 15 minutes. If an alarm has been silenced and a new one occurs, the MUTE function is cleared and the signal comes back until the cause has been attended to and the MUTE button is pushed again.

Alarm C44 is equipped with an environmental-friendly rechargeable NiMH back-up battery.

The sound volume is adjustable via a potentiometer placed behind the cover. At delivery the sound volume is set at Medium.

Art. Nr. Denomination 325197710P Gas alarm C44 recessed mounting325197711P Gas alarm C44 exposed mounting

1 sheet plastic strips for inserting will be delivered with the Alarm C44.Cut out the plastic strips, loosen the cover lid and insert the respective plastic strip into the correct pocket.

pLEAsE nOTE: All electronics is subjected to static electricity. Therefore, when working with Alarm C44 grounded wristbands should be used.

teChniCAL DAtATransformer: ~ 11,5V, 0.9 ABattery Pack: 9 VPower Consumption: about 300 mAWeight: 1 kgWorking temperature: 0-60 ºCRelay outputs: 4Relay supply voltage: 4 VBreaking current: 1A, 30 WDimension exposed mounting L×H×D: 191×100×53Dimension recessed mounting L×H×D: 180×90×70Recommended cable: Signal cable 0.25 mm2

Feed cable 0.75 mm2

Maximum cable lenght: 3 m (alarm-pressure switchs)Regulatory status: Complies with Medical Devices Directive 93/42/EEC Complies with EN ISO 7396-1 (Central Gas Supply System) EMC tested in accordance EN 60601-1-2 (Emission and immunity)

exPOseD MOuntinG

reCesseD MOuntinG

Note! Measurements in mm.

191

100 53

187

180

90 65 70

Page 106: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

104

GAs ALArM MC7701

This monitor gives visual and audible indications as well as status messages in plain language. When used with a manifold, the follows conditions are surveilled.1. Too high or too low operating pressure,2. Too high distribution pressure,3. Leakage on the non-operating gas cylinder bank,4. When change of operating side has been effected.

When connected to a liquid tank the following disturbances will be reported:1. Too high or too low operating pressure,2. Too high or too low distribution pressure,3. Leakage on the non operating gas cylinder bank.4. When change of operating side has been effected.

When used with a pressure watch the following conditions are surveilled: Too high or too low operating pressure.

The MC7701 is able to communication wtih another equipment through a serial link RS485, Modbus RTO and/or relays. The alarm has a battery back-up for 30 minutes of operation.

Art. Nr. Denomination 325197497P Digital pressure monitor MC7701 UNILARM

ACCessOries325112696P Cable with Hirsman contact 3m325112698P Cable with cable conecting piece 3 m325112496 Backup batteries MC7701325110804P Pressure Transmitter 0 - 50 mV G1/8 0-16 bar325110528P Pressure Transmitter 0 - 50 mV G1/8 0-25 bar325110527P Pressure Transmitter 0 - 50 mV G1/8 0-250 bar

teChniCAL DAtATransformer: ~ 24V, 1.3 ABattery Pack NiMH: 10,8 VPower Consumption: 15 WEnclosure: IP65Weight: 2kgWorking temperature: 0-60 ºCRelay outputs: 14stSerial communication: Modbus RTUDimension L×H×D: 275×175×67Dim. including fastening plate L×H×D: 310×175×67Display languages: Swedish, Norwegian, Danish, Finnish, English and HungarianRegulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System) EMC tested in accordance EN 60601-1-2 (Emission and immunity)

310

175

Note! Measurements in mm.

Page 107: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

105

GAs ALArM G4

The Gas Alarm G4 is a medical gas alarm that can be connected to pressure monitors with a digital gas pressure monitor MC 7701. If MC 7701 alarms the same alarm will be shown at G4. The Gas Alarm G4 can display alarms for four different gases, medical oxygen, medical N2O, medical air and instrumental air.The alarms are summation alarms for both high and low pressure.ln addition to this, a failure in the computer communication system, or a damaged signal cable (for example: cut off ) are also indicated.The loudness of the sound can be adjusted by using the potentionmeter placed behind the covering lid. At delive-ry the sound is set at medium.The Gas Alarm G4 is available in two diff erent designs, for recessed mounting and for exposed mounting.The display can show any of eight languages chosen from stickers enclosed. The alarm is equipped with a recharge-able battery in case of power failure.Gas Alarm G4 can only be used together with MC 7701. At the most 10 pcs of G4 can be connected in a series.

Art. Nr. Denomination 325197713 Gas alarm G4 recessed mounting 325197714 Gas alarm G4 exposed mounting

teChniCAL DAtABattery: 9 VWeight: 1 kgWorking temperature: 0-60°CPower supply: From MC 7701Recommended cable: Signal cable 0.75 mm2

Computer wire like Alpha type 5472C or similarMaximum cable lenght: 400 m (between two G4)Regulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 7396-1 (Central Gas Supply System). EMC-tested according to EN 60601-1-2 (Emission and immunitet).

191

100 53

187

180

90 65 70

COnneCtiOn DiAGrAM

MC7701

Alternative 1 (MC7701)

32=1 - signal

33=3 - +15 V

34=4 - GND

Alternative 2 (MC6701)

39=1

41=3

42=4

exPOseD MOuntinG

reCesseD MOuntinG

Note! Measurements in mm.

Page 108: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

106

MEDICAL TErMInAL UnITs

GCE MEDIUnIT-DIn TYpE

MeDiCAL terMinAL unitsMedical terminal units are providing quick and easy connect-ing of hospital ward gas equipment to the hospital gas source. Type of medical gas outlets are decided by the national stand-ards in each country and sometimes local requests in each hospital.

GCE helps to the installers to comply with ISO 7396 and national installation standards with secure products where every product is fully tested in production. Our Medical gas outlets are in accor-dance with ISO EN 9170-1 international standard.

Key BeneFits•Housing part in the wall is compatible for all GCE MediUnit by

standards like DIN, BSI, SS, CZ

•After 10 years life time upgrade by special pack without request for construction work

•Small size

•All functional component from brass

•Safety parking position

•Simple installation

•Easy to clean

•Fast connecting and disconnecting of hospital ward equipment to gas source

•Attractive design

•Recessed, Exposed and Bed head installation versions

•Complies with color coding and description by standard

• In accordance with ISO 9170-1

•Safety product, every piece is fully tested in production

Exposed version

Recessed version

Page 109: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

107

GCE MEDIUnIT - DIn

teChniCAL DAtA Gases: O2; N2O; AIR; CO2; VACDimensions: Height 73 mm Width 73 mm Depth 63 mmWeight: 0,36 kgWorking pressure: 4 - 5 barRegulatory status: Complies with Medical directive 93/42/EEC Complies with EN ISO 7396-1 (Central Gas Supply system) Complies with EN ISO 9170-1 (Terminal units) Complies with DIN 13260-2 (DIN gas specific connections)

Art. Nr. Description Gas Inlet0732020 TU DIN - recessed O2 pipe Ø100732021 TU DIN - recessed AIR pipe Ø100732022 TU DIN - recessed VAC pipe Ø100732023 TU DIN - recessed N2O pipe Ø100732024 TU DIN - recessed CO2 pipe Ø100732025 TU DIN - exposed O2 pipe Ø100732026 TU DIN - exposed AIR pipe Ø100732027 TU DIN - exposed VAC pipe Ø100732028 TU DIN - exposed N2O pipe Ø100732029 TU DIN - exposed CO2 pipe Ø10

instALLAtiOn tOOLsMP_00345 QC installation keyMP_00324 Button remover0732040 Installation plug (10 pcs)

MOuntinG

Installation plug

● Gas specific connection Probe - Terminal unit● Colour coding marking on terminal unit

● First position like on the picture is parking position ● Parking position is only holding Probe ● Parking position is without connection to the gas supply

● Push probe to working position like on the picture ● In working position Probe is connected to the gas supply ● Pressure drop is in accordance with EN 9170-1

● For disconnection Probe push and hold the button ● When button is hold Probe is locked in parking position and depressurize ● Then release the button Probe staying in parking position

● Depressurize Probe you can safety pull out from terminal unit

Page 110: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

108

GAs OUTLET MC70 (TErMInAL UnIT)

GCE gas outlets type MC 70 generation are self-sealing, i.e. they close automatically when a connected apparatus is removed. The gas outlets are furnished with a quick connection valve which means that the desired apparatus can be connected or disconnected by means of a simple one-step motion. The MC 70 gas outlets may be recessed in the wall or mounted in a panel. All MC 70 gas outlets have the same design but different colour codings and labels for different gases and of cour-se gas specific non-interchangeable quick connection valves. Special efforts have been made to make the maintenance of the gas outlets as easy as possible.

•No special tools •Maintenance valve of ball-type •Few components

Furthermore the MC 70 are made according to standard SS EN 8752430 for quick connections and international standard SS EN ISO 9170-1 for terminal units. This means that the gas components are non-interchangeable in every maintenance connection point. The gas outlet is delivered with separate packages for quick connection valve, valvebody, plastic cover with name plate, push-release plate etc. To make installation easier, the valve body has a tightening plug mounted for conve-nient pressure testing. All necessary mounting details such as brackets, screws etc. are included in the packages. Detailed instructions are also part of the delivery. When mounting the gas outlet in a recessed way the gas outlet can be mounted either in the front wall or in the rear wall, depending on which is first set up. Recessed and exposed instalation set is neces-sary orded separately.

GAs OutLetArt. Nr. Denomination Label denomination 325397281 Compl. for O2 O2 - white 325397282 Compl. for N2O N2O - blue 325397283 Compl. for AIR AIR - black/white 325397284 Compl. for VAC VAC - yellow325397285 Compl. for AGSS AGSS - purple325397286 Compl. for AIR-800 (I-AIR) AIR-800 - black/white325397287 Compl. for N2 N2 - black325397288 Compl. for CO2 CO2 - grey

FOr reCesseD MOuntinG ADDArt. Nr. Denomination325396031 Recessed installation set

FOr exPOseD MOuntinG ADDArt. Nr. Denomination325113415 Exposed installation set

teChniCAL DAtAMaximum working pressure: 10 barTube dimension: diameter 8 mmPressure class: PN 16Regulatory status: Complies with Medical Devices Directive 93/42/EEC. Complies with EN ISO 9170-1 (Terminal units standard) Complies with EN ISO 9170-2 (Terminal units AGSS) Complies with SS EN 8752430 (Type standard)

LABeLs M70Art. Nr. Denomination548234A26760 Circular Label O2 White 85/55 TU SS548234A26770 Circular Label N2O Blue 85/55 TU SS548234A26780 Circular Label AIR Black/White 85/55 TU SS548234A37600 Circular Labe AIR-800 (I-AIR) Black/White 85/55 TU SS548234A26790 Circular Label VAC Red 85/55 TU SS548234A26800 Circular Label VAC Yellow 85/55 TU SS548234A40850 Circular Label GASUTLOPP Blue/Brown 85/55 TU SS548234A40860 Circular Label GASUDLØB Blue/Brown 85/55 TU SS548234A40870 Circular Label GASSUTLØP Blue/Brown 85/55 TU SS548234A40880 Circular Label KAASUJEN POISTO Blue/Brown 85/55 TU SS548234A26810 Circular Label AGSS Purple 85/55 TU SS

Page 111: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

109

ACCEssOrIEs AnD OTHErs sAfETY VALVE MEDICAL pIpELInE sYsTEMs

The safety valve is used in medical pipeline systems to secure that the pressure does not exceed 6,8 bar. The safety valve shall be mounted on outgoing pipelines on Simplex MMR or can be mounted on other pipelines.

•Bracket for wall mounting

sAFety vALve tuBe MOuntinGArt. Nr. Gas Relief Inlet connection Outlet connection Pressure 325197387 Medical gases and air 6,8 bar G 3/4 F G 3/4 F

sAFety vALve siMPLex MMr MOuntinGArt. Nr. Gas Relief Inlet connection Outlet connection Pressure 325197306 Medical gases and air 6,8 bar G 3/8 F G 3/4 F

teChniCAL DAtA Evacutaion flow: 130 m3/hEvacutaion outlet pipe: Ø 15 mmRelief pressure: 6,8 barMaterial: Brass, copper, stainless steel, rubberPressure class: PN16Regulatory status: Degreesing for Oxygen use no CE-marking

Page 112: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

110

prEssUrE TrAnsMITTEr

Small compact pressure transmitter with god performance.Suitable for mobile applications when vibration reliable sensors are needed.Compact connectors.

•Max. deviation 1,0%•For relative pressure•Pressure range from 0...0,25 bar to 0...1000 bar•Degreased for Oxygen

Art. Nr. Denomination Pressure Thread Cable325112798P Pressure transmitter 0-16 bar G1/4 1 m325112799P Pressure transmitter 0-25 bar G1/4 1 m325112800P Pressure transmitter 0-250 bar G1/4 1 m

teChniCAL DAtAPerformance: Pressure range ≤16 bar Piezoresistive sensor Pressure range ≥25 bar hin film-sensorMax. deviation: ≤1,0% of end value according to DIN 16086≤0,5% BFSL)Liniarity and hysteresis: Included in aboveRepeat accurasy: ≤±0,05% of end valueLong term: ≤±0,2% of end value per annumOverpressure sensitivity: ≤16 bar 3,5×; ≤600 bar 2×; >600 bar 1,5×Underpressure sensitivity: Insensitive for vacuumResponse time: ≤1 ms for 10-90% of rangePressure connection: G1/4“ External threadSensor body: Acid-proof stainless steel SIS2350Parts in connection: with the medium: Acid-proof stainless steel SIS2350Mediun temperature: -30°C till +100°CSurrounding temperature: -30°C till +85°CTemperature deviation: ±0,3% of measure range/10K for zero and measure rangeTemp.compensated range: 0°C till +80°CSignal alternative: 4-20 mA, 0-10VSupply Voltage: Signal 4-20 mA 10-30V DC Signal 0-10V 14-30V DCMax. permitted load for: RA[Ω]=UB[V]-10V signal 4-20 mA 0,02AMax. permitted load for: RA>10kΩ signal 0-10VElektrcal connection: Contact Hirschmann-Mini G4a1MMT Polarity reversal safe, short circuit and overload protectedAdjustability: Not adjustableProtective class: IP65 acc. to EN 60529/IEC529EMC-data: Emmision EN 61326 Immunity EN 61326Weight: 0,10 kg

2-wire mA 3-wire V DCSupply voltage UB+ 1 1Supply voltage OV- 2 2Signal S+ 3Signal S- 2

MeAsureMents

COnneCtiOn

Page 113: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

111

HIGH prEssUrE COMpOnEnTsGCE can supply a wide range of components making it possible to install a medical gas supply system. All components are designed and manufacturedaccording to the relevant standard for high pressure systems. The high pressure pipe components are manufactured in the following materials: stainless steel AISI 316 L and brass CuZn39Pb3, and they are tested at 360 bar. Retaining brackets for cylinders and connecting pipes are manufactured in AISI 306.

COnnECTInG pIpEs fOr CYLInDEr MAnIfOLDs

Connecting pipes with retaining brackets of stainless steel, for 1-4 cylinders.

Art. Nr. Connecting threads Length (mm) Number of cylinders325197218 W 21,8×1/14"RH EXT-INT 290 1 215191072 W 21,8×1/14"RH EXT-INT 580 2215191073 W 21,8×1/14"RH EXT-INT 1160 4

CYLInDEr rETAInInG brACKETs

Cylinder retaining brackets, completely made of stainless steel, for 1 or 2 cylinders.

Art. Nr. Length (mm) Number of cylinders215191074P 260 1215191075P 550 2

COnnECTIOn pIpEs fOr CYLInDEr pACK MAnIfOLDs

Art. Nr. Connecting threads Length (mm) Number of cylinders215191012 W 21,8×1/14"RH EXT-INT 290 1215191013 W 21,8×1/14"RH EXT-INT 580 2215191014 W 21,8×1/14"RH EXT-INT 1159 4

EXTEnsIOn pIpEs

Art. Nr. Connecting threads Length (mm) 215191011 W 21,8×1/14"RH EXT-INT 700

Page 114: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

112

COnnECTInG COMpOnEnTs fOr CYLInDEr MAnIfOLDs

Art. Nr. Description Thread Position215191010 Connection pipe 90o W 21,8×1/14” 1215191077 Blind plug W 21,8×1/14” 2215191068 Adaptor W 21,8×1/14”male LH/ female RH 3200059835P Coupling nut W 21,8×1/14” LH/RH 4215191080 End plug with nut W 21,8×1/14” 5215191085 T-pipe for DUPLEX W 21,8×1/14” 6215191126 S-pipe W21,8×1/14” 7202502362 Aluminium washer 50 pcs 16/12.5×1.5 mm325111032P Copper washers 10 pcs 18/12,7×1.5 mm

nOn-rETUrn VALVEs fOr COnnECTIOn pIpEs

Art. Nr. Denomination 215191044 Non-return valve for connection pipes

HIGH prEssUrE fILTEr

Art. Nr. Denomination 215190042 High pressure filter

HIGH prEssUrE VALVEs 300 bAr

Art. Nr. Inlet Outlet0765001 W 21,8×1/14"RH W 21,8×1/14"LH

HIGH prEssUrE VALVEs 200 bAr

Art. Nr. Inlet Outlet 0765822 W 21,8×1/14"RH W 21,8×1/14"LH

1 2 3 4 5 6 7

Page 115: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

113

rEGULATOrs AnD fLOw METErs fOr MEDICAL GAsEs

iMPOrtAnt inFOrMAtiOn AnD reCOMMenDAtiOnsOur products are reliable and accurate instruments made in compliance with strict international standards and, if used and maintained according to the instructions provided in the information leaflet, they require no special servicing and repairs, except the following:

1. Replacement of a gasket on the inlet connection - to be performed every six to eight months by the user. Use only gaskets supplied by the manufacturer or supplier of the regulator as they are made of a special non-combustible material.

2. Functional and performance check of the product - to be performed once a year by the manufacturer or by an authorized servicing company.

3. Product inspection - to be performed every five to six years after the manufacturing date by the manufacturer or by an authorized servicing company. The inspection consists in a replacement of rubber parts of the product and its functional check.

4. Repairs - in case of any defects or damage the product shall be delivered to the manufacturer or to an authorized servicing company to be professionally repaired. The maximum service life of the regulator is ten years from the manufacturing date. The manufacturing date is marked on each product as a part of the serial number.

EXAMpLE fOr prODUCTs MADE bY THE bEGInnInG Of 1999: serial number 99014151

4151

ordinal numberyear manufacture 1999

month of manufacture - January

0199

4151

ordinal numberyear manufacture 2001

month of manufacture - June

0601

GCE has introduced and certified its quality management system according to IS013485:2003 for medical devices.

The products meet the requirements of the EU Directive 93/42/EEA and they are certified and provided with the CE mark.

Any requirements for other technical parameters shall be discussed with the manufacturer.

EXAMpLE fOr prODUCTs MADE DUrInG 2000: serial number 010616539

sAFety instruCtiOnsThe objective of the company GCE is not only customer satisfaction with reliable products but also safe operation of all equipment associated with medicinal gases. Therefore is it necessary to observe all instructions for the use and, particularly, the following safety principles:

1. Concentrated oxygen shall not come into contact with oils, grease and impurities to prevent its self-ignition.2. Pressure cylinders shall be always secured against fall, exposure to heat and manipulation by unauthorized person.3. Smoking and open fire manipulations are strictly prohibited in the proximity of pressure cylinders or gas equipment.4. Personnel working with classified gas equipment shall be properly trained.5. Any servicing of regulators, flow meters, combined valves and concentrators shall be requested only from specialist servicing

organizations.

CertiFiCAtiOn

Page 116: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

114

CErTIfICATEs

Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid.This Certificate has been digitally signed. See www.dnv.com/digitalsignatures for more info

HEAD OFFICE. Det Norske Veritas AS, Veritasveien 1, 1322 Hovik, Norway. Tel: +47 67 57 99 00 Fax: +47 67 57 99 11 - www.dnv.com

DNV BUSINESS ASSURANCEMANAGEMENT SYSTEM CERTIFICATE

Certificate No. 109396-2012-AQ-CZS-NA

This is to certify that the Management System of:

GCE Holding AB

Källvattengatan, SE-200 21, Malmö, Sweden

has been found to conform to the standard:

ISO 9001:2008

This Certificate is valid for the following product or service ranges:

Design, production, sales and servicing of equipment for using of technical gases in industry. Pressure regulators, closing, combined and special valves, cutting, welding, heating and brazing torches, safety equipment, speciality torches, fittings, accessories

for industrial purposes.

Initial Certification date:28 February 1997

MSYS 002

Place and date:Høvik, 28 February 2012

This Certificate is valid until:

28 February 2015

for the Accredited Unit:DET NORSKE VERITAS

CERTIFICATION AS, NORWAY

The audit has been performed under the supervision of

Evangelos Tavandžis Bjørg Synnøve NesgårdLead Auditor Management Representative

Lack of fulfilment of conditions as set out in the Certification Agreement may render this Certificate invalid.This Certificate has been digitally signed. See www.dnv.com/digitalsignatures for more info

HEAD OFFICE. Det Norske Veritas AS, Veritasveien 1, 1322 Hovik, Norway. Tel: +47 67 57 99 00 Fax: +47 67 57 99 11 - www.dnv.com

DNV BUSINESS ASSURANCEMANAGEMENT SYSTEM CERTIFICATE

Certificate No. 109399-2012-AQ-CZS-NA

This is to certify that the Management System of:

GCE Holding AB

Källvattengatan 9, SE-200 21, Malmö, Sweden

has been found to conform to the standard:

ISO 13485:2003

This Certificate is valid for the following product or service ranges:

Design, production, sales and servicing of medical devices for using of medical gases in health service. Pressure regulators, terminal units, suction equipment, medical hoses,

cylinder and combi valves and flow meters for medical gases.

Initial Certification date:28 February 1997

MSYS 002

Place and date:Høvik, 28 February 2012

This Certificate is valid until:

28 February 2015

for the Accredited Unit:DET NORSKE VERITAS

CERTIFICATION AS, NORWAY

The audit has been performed under the supervision of

Evangelos Tavandžis Bjørg Synnøve NesgårdLead Auditor Management Representative

Page 117: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

115

GEnErAL bUsInEss TErMs AnD COnDITIOnsPreAMBLe1. These General Conditions shall apply when the parties agree in writing or otherwise thereto. Deviations from the Conditions shall not apply unless agreed in writing.When used in these conditions the term “written” or “in writing” refers to a document signed by both parties or a letter, fax, electronic mail or other means agreed by the parties.

PrODuCt inFOrMAtiOn2. Data in product information and price lists are binding only to the extent that they are expressly referred to in the contract.

teChniCAL DOCuMents AnD teChniCAL inFOrMAtiOn 3. All drawings and other technical documents regarding the goods or their manufacture submitted by one party to the other, prior or subsequent to the formation of the contract, shall remain the property of the submitting party.Drawings, technical documents or other technical information received by one party shall not, without the consent of the other party, be used for any other purpose than that for which they were submitted. They may not without the consent of the other party be copied, reproduced, transmitted or otherwise communicated to a third party.4. The Seller shall, not later than by delivery of the goods, free of charge provide the Buyer with one copy, or the larger number of copies that may have been agreed, of drawings and other technical documents, which are sufficiently detailed to permit the Buyer to carry out installation, commissioning, operation and maintenance (including running repairs) of all parts of the goods. The Seller shall not, however, be obliged to supply manufacturing drawings of the goods or spare parts.

DeLivery test5. Where a delivery test has been agreed, it shall, unless otherwise agreed, be carried out where the goods are manufactured.If technical requirements for the test have not been agreed, the test shall be carried out in accordance with general practice in the industry concerned in the country where the goods are manufactured.6. The Seller shall notify the Buyer in writing of the delivery test in sufficient time to permit the Buyer to be present at the test.If the Buyer has received such notice, the test may be carried out even if the Buyer is not represented at the test.The Seller shall record the test. The test report shall be sent to the Buyer. The report shall, unless otherwise shown by the Buyer, be considered to correctly describe the execution of the test and its results.7. If at the delivery test the goods are found not to be in accordance with the contract, the Seller shall as soon as possible ensure that the goods comply with the contract. If so required by the Buyer a new test shall thereafter be carried out. The Buyer may not, however, require a new test if the defect was insignificant.8. If no other division of the costs has been agreed, the Seller shall bear all costs for delivery tests carried out where the goods are manufactured. The Buyer shall, however, at such delivery tests bear all costs for his repre-sentatives, including costs for travel and subsistence.

DeLivery9. Where a trade term has been agreed, it shall be interpreted in accordance with the INCOTERMS in force at the formation of´the contract. If no trade term is specifically agreed, the delivery shall be Ex Works.

tiMe FOr DeLivery DeLAy10. If, instead of a fixed date for delivery, the parties have agreed on a period of time within which delivery shall take place, such period shall start to run at the formation of the contract.11. If the Seller finds that he will not be able to deliver the goods at the agreed time or if delay on his part seems likely, he shall without undue delay notify the Buyer thereof in writing, stating the reason for the delay and if possible the time when delivery can be expected. If the Seller fails to give such notice, he shall, regardless of the provisions of Clauses 13 and 14, reimburse the Buyer for any additional expenses, which the latter incurs and which he would have avoided, had he received notice in time.12. If delay in delivery is caused by a circumstance which under Clause 36 constitutes ground for relief or by an act or omission on the part of the Buyer, including suspension by the Seller under Clause 18, the time for delive-ry shall be extended by a period, which is reasonable having regard to the circumstances in the case. The time for delivery shall be extended even if the reason for delay occurs after the originally agreed time for delivery.13. If the Seller fails to deliver the goods on time, the Buyer is entitled to liquidated damages from the date on which delivery should have taken place.The liquidated damages shall be payable at a rate of 0.5 per cent of the agreed price for each complete week of delay. If the delay concerns only a part of the goods, the liquidated damages shall be calculated on the part of the price which is properly attributable to the part of the goods which cannot be taken in use due to the delay.The liquidated damages shall not exceed 7.5 per cent of that part of the price on which it is calculated.The liquidated damages become due at the Buyer’s written demand but not before all of the goods have been delivered or the contract is terminated under Clause 14.The Buyer loses his right to liquidated damages if he has not lodged a written claim for such damages within six months after the time when delivery should have taken place.14. If the Buyer is entitled to maximum liquidated damages under Clause 13, and the goods are still not delivered, the Buyer may in writing demand delivery within a final reasonable period which shall not be less than one week.If the Seller fails to deliver within such final period and this is not due to any circumstance for which the Buyer is responsible, the Buyer may, by written notice to the Seller, terminate the contract in respect of that part of the goods which cannot be taken in use due to the delay.In case of such termination the Buyer shall also be entitled to compensation for the loss he suffers because of the Seller’s delay to the extent that the loss exceeds the maximum of liquidated damages which the Buyer may claim under Clause 13. This compensation shall not exceed 7.5 per cent of that part of the price which is properly attributable to the part of the goods in respect of which the contract is terminated.The Buyer shall also have the right to terminate the contract by written notice to the Seller if it is clear that there will be a delay, which under Clause 13 would entitle the Buyer to maximum liquidated damages. In case of ter-mination on this ground the Buyer shall be entitled to both maximum liquidated damages and compensation under the third paragraph of this Clause.Except for liquidated damages under Clause 13 and termination of the contract with limited compensation under this Clause 14, all other claims in respect of the Seller’s delay shall be excluded. This limitation of the Seller’s liability shall not apply, however, where the Seller has been guilty of gross negligence. 15. If the Buyer finds that he will be unable to accept delivery of the goods on the agreed date, or if delay on his part seems likely, he shall without undue delay notify the Seller thereof in writing stating the reason for the delay and, if possible, the time when he will be able to accept delivery.If the Buyer fails to accept delivery on the agreed date, he shall nevertheless make any payment which is dependent on delivery as if the goods in question had been delivered. The Seller shall arrange storage of the goods at the Buyer’s risk and expense. If the Buyer so requires, the Seller shall insure the goods at the Buyer’s expense.16. Unless the Buyer’s failure to accept delivery as referred to in Clause 15 is due to any such circumstance as described in Clause 36, the Seller may by written notice require the Buyer to accept delivery within a reasonable period.If, for any reason for which the Seller is not responsible, the Buyer fails to accept delivery within such period, the Seller may, by written notice to the Buyer, terminate the contract in respect of that part of the goods which is ready for delivery but has not been delivered due to the Buyer’s default. The Seller shall then be entitled to compensation for the loss he has suffered by reason of the Buyer’s default. The compensation shall not exceed that part of the price which is properly attributable to the part of the goods in respect of which the contract is terminated.

PAyMent17. Unless otherwise agreed, the agreed purchase price, together with value added tax, if any, shall be invoiced with one third at the formation of the contract, one third when the Seller gives written notice that the bulk of the goods are ready for delivery. Final payment shall be invoiced at delivery of the goods. The invoiced amount becomes due 30 days after the date of the invoice.18. If the Buyer fails to pay, the Seller shall be entitled to interest from the due date at the rate of interest determined by the law on late payments in the Seller’s country.

If the Buyer fails to pay by the due date, the Seller shall also, after having notified the Buyer in writing thereof, suspend performance of his contractual obligations until payment is made.19. If the Buyer has failed to pay the amount due within three months after the due date, the Seller may terminate the contract by written notice to the Buyer and, in addition to interest on late payment, claim compensation for the loss he has suffered. The compensation shall not exceed the agreed purchase price.

retentiOn OF titLe20. The goods shall remain the property of the Seller until paid for in full, to the extent that such retention of title is valid.

LiABiLity FOr DeFeCts21. The Seller shall, in accordance with the provisions of Clauses 23–33 below, remedy any defect in the goods resulting from faulty design, materials or workmanship.The Seller is not liable for defects arising out of material provided by the Buyer or a design stipulated or specified by him.22. The Seller’s liability does not cover defects caused by circumstances, which arise after the risk has passed to the Buyer.The liability does not, for example, cover defects due to conditions of operation deviating from those antici-pated in the contract or to improper use of the goods. Nor does it cover defects due to faulty maintenance or incorrect installation from the Buyer’s side, alterations undertaken without the Seller’s written consent or faulty repairs by the Buyer. Finally the liability does not cover normal wear and tear or deterioration.23. The Seller’s liability is limited to defects which appear within a period of one year from the date of delivery of the goods. If the goods are used more intensely than agreed, this period shall be reduced proportionately.24. For parts, which have been repaired or replaced under Clause 21, the Seller shall have the same liability for defects as for the original goods for a period of one year. For other parts of the goods the liability period referred to in Clause 23 shall be extended only by the period during which the goods could not be used due to a defect for which the Seller is liable.25. The Buyer shall notify the Seller in writing of a defect without undue delay after the defect has appeared and in no case later than two weeks after the expiry of the liability period defined in Clause 23 as supplemen-ted by Clause 24. The notice shall contain a description of how the defect manifests itself. If the Buyer fails to notify the Seller in writing within the above time limits, he loses his right to make any claim in respect of the defect. If there is reason to believe that the defect may cause damage, notice shall be given forthwith. If notice is not given forthwith, the Buyer loses the right to make any claim based on damage which occurs and which could have been avoided if such notice had been given.26. After receipt of a written notice under Clause 25, the Seller shall remedy the defect without undue delay. Within this limit the time for remedial work shall be chosen in order not to interfere unnecessarily with the Buyer’s activities. The Seller shall bear the costs as specified in Clauses 21–32.Remedial work shall be carried out at the Buyer’s premises unless the Seller finds it appropriate to have the defective part or the goods sent to him for repair or replacement at his own premises.The Seller shall carry out dismantling and re-installation of the part if this requires special knowledge. If such special knowledge is not required, the Seller has fulfilled his obligations in respect of the defect when he delivers a duly repaired or replaced part to the Buyer.27. If the Buyer gives such notice as referred to in Clause 25, and no defect is found for which the Seller is liable, the Seller shall be entitled to compensation for the work and costs which he has incurred as a result of the notice. 28. If remedy of the defect requires intervention in other equipment than the goods, the Buyer shall be respon-sible for any work or costs caused thereby.29. All transports in connection with repair or replacement shall be at the Seller’s risk and expense.The Buyer shall follow the Seller’s instructions regarding how the transport shall be carried out.30. The Buyer shall bear the increase in costs for remedying a defect which the Seller incurs when the goods are located elsewhere than at the destination stated in the contract or – if no destination has been stated – the place of delivery.31. Defective parts, which have been replaced under Clause 21, shall be placed at the Seller’s disposal and shall become his property.32. If the Seller fails to fulfil his obligations under Clause 26 within a reasonable time, the Buyer may by written notice require him to do so within a final time. If the Seller fails to fulfil his obligations within that time limit, the Buyer may at his option:a) have the necessary remedial work carried out and/or have new parts manufactured at the Seller’s risk and expense, provided that the Buyer proceeds in a reasonable manner, orb) demand a reduction of the agreed purchase price not exceeding 15 per cent thereof.If the defect is substantial, the Buyer may instead terminate the contract by written notice to the Seller. The Buyer shall also be entitled to such termination where the defect remains substantial after measures referred to in a). In case of termination, the Buyer shall be entitled to compensation for the loss he has suffered. The compensation shall not, however, exceed 15 per cent of the agreed purchase price.33. Regardless of the provisions of Clauses 21–32, the Seller shall have no liability for defects in any part of the goods for more than two years from the start of the liability period referred to in Clause 23.34. The Seller shall have no liability for defects save as stipulated in Clauses 21–33. This applies to any loss the defect may cause, such as loss of production, loss of profit and other consequential economic loss. This limita-tion of the Seller’s liability shall not apply, however, if he has been guilty of gross negligence.

LiABiLity FOr DAMAGe tO PrOPerty CAuseD By the GOODs35. The Buyer shall indemnify and hold the Seller harmless to the extent that the Seller incurs liability towards any third party in respect of loss or damage for which the Seller is not liable towardsthe Buyer according to the second and third paragraphs of this Clause.The Seller shall have no liability for damage caused by the goods:a) to any (movable or immovable) property, or consequential loss due to such damage, occurring while the goods are in the Buyer’s possession, or b) to products manufactured by the Buyer or to products of which the Buyer’s products form a part.The above limitations of the Seller’s liability shall not apply if he has been guilty of gross negligence.If a third party lodges a claim for compensation against Seller or Buyer for loss or damage referred to in this Clause, the other party to the contract shall forthwith be notified thereof in writing.The Seller and the Buyer shall be mutually obliged to let themselves be summoned to the court or arbitral tribunal which examines claims against either of them based on damage or loss alleged to have been caused by the goods. The liability as between the Seller and the Buyer shall, however, always be settled by arbitration in accordance with Clause 39.

GrOunDs FOr reLieF (FOrCe MAjeure)36. The following circumstances shall constitute grounds for relief if they impede the performance of the contract or makes performance unreasonably onerous: industrial disputes and any other circumstance beyond the control of the parties, such as fire, war, mobilization or military call up of a comparable scope, requisition, seizure, trade and currency restrictions, insurrection and civil commotion, shortage of transport, general shortage of materials, restrictions in the supply of power and defects or delays in deliveries by sub-contractors caused by any such circumstance as referred to in this Clause.The above described circumstances shall constitute grounds for relief only if their effect on the performance of the contract could not be foreseen at the time of formation of the contract.37. The party wishing to claim relief under Clause 36 shall without delay notify the other party in writing on the intervention and on the cessation of such circumstance.If grounds for relief prevent the Buyer from fulfilling his obligations, he shall reimburse the expenses incurred by the seller in securing and protecting the goods.38. Notwithstanding other provisions of these General Conditions, either party shall be entitled to terminate the contract by notice in writing to the other party, if performance of the contract is delayed more than six months by reason of any grounds for relief as described in Clause 36.

DisPutes APPLiCABLe LAw39. Disputes arising out of or in connection with the contract shall not be brought before the court, but shall be finally settled by arbitration in accordance with the law on arbitration applicable in the Seller’s country.40. All disputes arising out of the contract shall be judged according to the law of the Seller’s country.

Page 118: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

116

nOTEs

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 119: MEDICAL CATALOGUE - GCE Group MEDICAL... · MEDICAL CATALOGUE . GCE ... Safety Valve Medical Pipeline Systems ... Flow range Inlet Outlet ...

Art

. Nr.

CATR

OM

ED01

14. E

ditio

n 1/

2014

. Alte

ratio

ns a

re s

ubje

ct to

cha

nge

with

out n

otic

e. 1

7022

014m

d© G

CE 2

014

Romania, Moldova, TurciaGCE Romania SRL

Str. Al. Puskin, Nr.22, Ap.1,Parter, Sector 1

Bucuresti, 011996ROMANIA

Tel. +40 21 316 76 72Fax: +40 21 316 76 74

www.gcegroup.com

GCE Group is one of the world’s leading companies in the field of gas control equipment. The headquarters are in Malmö, Sweden, and the two major supply units are located in Europe and Asia.The company operates 15 subsidiaries around the world and employs more than 850 people. GCE Groupincludes four business areas – Cutting & Welding, Process Applications, Medical and High Purity. Today’sproduct portfolio corresponds to a large variety of applications, from single pressure regulators and blowpipes for cutting and welding to sophisticated gas supply systems for medical and electronics industry applications.