Measurement of the electron’s electric dipole moment

27
Measurement of the electron’s electric dipole moment Mike Tarbutt Centre for Cold Matter, Imperial College London. Ripples in the Cosmos, Durham, 22 nd July 2013

description

Measurement of the electron’s electric dipole moment. Mike Tarbutt Centre for Cold Matter, Imperial College London. Ripples in the Cosmos, Durham, 22 nd July 2013. -. 10 -22. Spin. Spin. +. Edm. Edm. 10 -24. MSSM. 10 -26. Multi Higgs. Left -Right. Either d e = 0, or T. - PowerPoint PPT Presentation

Transcript of Measurement of the electron’s electric dipole moment

Page 1: Measurement of the electron’s electric dipole moment

Measurement of the electron’s electric dipole moment

Mike TarbuttCentre for Cold Matter, Imperial College London.

Ripples in the Cosmos, Durham, 22nd July 2013

Page 2: Measurement of the electron’s electric dipole moment

+- Spin

Edm+-Spin

Edm

The electron’s electric dipole moment (EDM, de)

T

T CPimplies

Insufficient CP

Either de = 0, or T

10-24

10-22

10-26

10-28

10-30

10-32

10-34

10-36

Multi Higgs Left -

Right

MSSM

Other SUSY

Standard ModelPr

edic

ted

valu

es fo

r the

ele

ctro

n ed

m d

e (e.

cm)

Page 3: Measurement of the electron’s electric dipole moment

Measuring the EDM – spin precessionB & E

EParticle precessing in

a magnetic fieldParticle precessing in parallel magnetic and

electric fields

Particle precessing in anti-parallel magnetic

and electric fields

Measure change in precession rate when electric field direction is reversedWe use the valence electron in the YbF molecule

Page 4: Measurement of the electron’s electric dipole moment

We use a beam of YbF molecules

Effe

ctiv

e fie

ld,

E eff (

GV

/cm

)

Interaction energy = - de .Eeff

Eeff = F P

Structure dependent, ~ 10 (Z/80)3 GV/cm

Polarization factor

Page 5: Measurement of the electron’s electric dipole moment

Pulsed YbF molecular beam

hf = 2mB

2nd rf pulse

1st rf pulse

± 2 de EeffE

±B

analyze spin direction

Simplified measurement scheme

Page 6: Measurement of the electron’s electric dipole moment

Result (2011)

de = (-2.4 ± 5.7stat ± 1.5syst) × 10-28 e.cm

| de | < 10.5 × 10-28 e.cm (90% confidence level)

6194 measurements of the EDM, each derived from 4096 beam pulses Each measurement takes 6 minutes

Nature 473, 493 (2011)

Page 7: Measurement of the electron’s electric dipole moment

Implications

10-24

10-22

10-26

10-28

10-30

10-32

10-34

10-36

Multi Higgs Left -

Right

MSSM

Other

SUSY

Standard Model

Pred

icte

d va

lues

for t

he e

lect

ron

edm

de (

e.cm

)

Mass of new particle

CP-violating phase

For Ms= 200 GeV and qCP ≈1

=> de ≈ 10-24 e.cm

Excluded region

Ms > 4 TeV ? qCP < 10-3 ?

e e

gselectron

gaugino

Page 8: Measurement of the electron’s electric dipole moment

Some other electron EDM experiments

• ThO at Harvard \ Yale - new result anticipated with very high sensitivity

• WC at Michigan – in development

With molecules:

• HfF+ at JILA – trapped ion with rotating E & B fields, very long coherence times, being developed

With ions:

• Gadolinium Garnets at LANL and Amherst – lots of electrons, but difficult to control systematic effects

With solids:

• Trapped ultracold Cs at Penn State and U. Texas, being developed

• Trapped ultracold Fr at Tohoku / Osaka, being developed

With atoms:

Page 9: Measurement of the electron’s electric dipole moment

d(m) 2×10-19

d(n) 3×10-26

d(p) 6×10-23

d(e) 1×10-27

10-20

10-22

10-24

s [d

] (e

.cm

)1960 1970 1980 1990 2000 2010 2020 2030

10-28

electron:neutron:

10-26

Year

Particle EDMs - historic and present limits

Page 10: Measurement of the electron’s electric dipole moment

M. Le Dall and A. Ritz, Hyperfine Interactions 214, 87 (2013)

CMSSM constraints from EDM measurements

tan b = 3, MSUSY=500GeV

Page 11: Measurement of the electron’s electric dipole moment

Future experiments with YbF molecules

Upgrades to existing experiment – x10 improvement (in progress)

x1000 improvement

Molecular fountain of ultracold YbF molecules (under development)

Page 12: Measurement of the electron’s electric dipole moment

Thanks...

Ed Hinds

Dhiren Kara

Ben SauerJony Hudson

Jack Devlin Joe Smallman

Page 13: Measurement of the electron’s electric dipole moment

The YbF EDM experiment – schematic

J. J. Hudson, D. M. Kara, I. J. Smallman, B. E. Sauer, M. R. Tarbutt & E. A. Hinds, Nature 473, 493 (2011)

Page 14: Measurement of the electron’s electric dipole moment

Atom / MoleculeElectricField

E

Using atoms & molecules to measure de

Interaction energy = - de .Eeff

Eeff = F P

Structure dependent, ~ 10 (Z/80)3 GV/cm

Polarization factor

For more details, see E. A. Hinds, Physica Scripta T70, 34 (1997)

For a free electron in an applied field E, expect an interaction energy -de.EN.B. Analogous to interaction of magnetic dipole moment with a magnetic field, -m . B

Page 15: Measurement of the electron’s electric dipole moment

Ground state YbF

-de Eeff

de Eeff

X 2S+ (n = 0, N = 0)

-1 +10F = 1

F = 0

170 MHz

MF

ElectricField

E

We measure the splitting 2deEeff between the MF = +1 and MF = -1 levels

Page 16: Measurement of the electron’s electric dipole moment

Measurement scheme – a spin interferometer

Pulsed YbF beam

PumpA-X Q(0) F=1

ProbeA-X Q(0) F=0

PMT

3K beam

F=1

F=0

rf pulse

B HV+

HV-

Page 17: Measurement of the electron’s electric dipole moment

Counts

BEE

Measuring the edm with the interferometer

Signal α cos2 [f/2] = cos2 [(mB B – de Eeff ) T / ћ]

Page 18: Measurement of the electron’s electric dipole moment

Modulate everything

±E±B

±B

±rf2f±rf1f

±rf2a±rf1a

±laser f±rff

spin interferometer

Signal

9 switches:

512 possible correlations

The EDM is the signal correlated with the sign of E.B We study all the other 511 correlations in detail

Page 19: Measurement of the electron’s electric dipole moment

F = 0

F = 1

rf

E

Star

k-sh

ifted

hy

perf

ine

inte

rval

F = 0

F = 1

rf

E

Star

k-sh

ifted

hy

perf

ine

inte

rval

rf detuning

phase shift: ~100 nrad/Hz

Imperfect E-reversal

Changes detuning via Stark shift

Phase correlated with E-direction

Correction to EDM: (5.5 ± 1.5) × 10-28 e.cm

Correcting a systematic error

Page 20: Measurement of the electron’s electric dipole moment

Effect Systematic uncertainty (10-28 e.cm)

Electric field asymmetry 1.1

Electric potential asymmetry 0.1

Residual RF1 correlation 1.0

Geometric phase 0.03

Leakage currents 0.2

Shield magnetization 0.25

Motional magnetic field 0.0005

Systematic uncertainties

Page 21: Measurement of the electron’s electric dipole moment

How to do better

The statistical uncertainty scales as: 1N

1T 1

E

Total number of participating molecules

Coherence time

Electric field

Page 22: Measurement of the electron’s electric dipole moment

Cryogenic source of YbF

Produce YbF molecules by ablation of Yb/AlF3 target into a cold helium buffer gas Helium is pumped away using charcoal cryo-sorbs Produces intense, cold, slow-moving beams

Page 23: Measurement of the electron’s electric dipole moment

Cold, slow beam of YbF molecules

Rotational temperature: 4 ± 1 K Translational temperature: 4 ± 1 K

Speed vs helium flow

Mol

ecul

es /

ster

adia

n / p

ulse

Flow rate / sccm

Flux vs helium flow

Page 24: Measurement of the electron’s electric dipole moment

Magnetic guide

Permanent magnets in octupole geometry, depth of 0.6 T Separates YbF molecules from helium beam Guides 6.5% of the distribution exiting the source

Page 25: Measurement of the electron’s electric dipole moment

Laser cooling

Laser cooling is the key step!!

LaserLaser

Ground state

Excited state

AbsorptionSpontaneous emission

v’’= 0

v’= 0

v’’=1v’’=2X2S(N=1)

A2½

552 nm

584 nm568 nm

92.8%6.9%

0.3%

Page 26: Measurement of the electron’s electric dipole moment

Simulations for YbF in an optical molasses

6 beams each containing 12 frequencies from 3 separate lasers

– 750 mW total

Page 27: Measurement of the electron’s electric dipole moment

Sensitivity of an EDM fountain experiment

Quantity Value How determined?

Molecules in cell 1013 Measured by us

Extraction efficiency 0.5 % Measured by Doyle group

Fraction in relevant rotational state 24 % Boltzmann distribution

Fraction accepted by guide 6.5 % Magnetic guide simulation

Fraction cooled in molasses 0.76 % Molasses simulation

Rotational state transfer efficiency 100 % Pi-pulse

Fraction though fountain 7.5 % Free-expansion at 185mK

Detection efficiency 100 % Fluorescence on closed transition

Coherence time 0.25 s By design

Repetition rate 2 Hz By design

EDM sensitivity in 8 hours 6 x 10-31 e.cm Statistical sensitivity