May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in...

16
Tel (604) 576-1808 aeconcrete.com May 2017 Sales Office: Shipping: Page 1 19060-54th Avenue, Surrey, B.C. Canada V3S 8E5 5353-192nd Street, Surrey, B.C. Canada V3S 8E5 Headwall Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) HDSP-21-ZZZZ-C Highways 16-SP 219 w/ Grillage, MOTH Dwg# SP582-04.01 (For up to 450mmØ RCP Pipe) 1280 x 920 x 1530 o.d. HD01-21-ZZZZ-C Type 1 Inlet w/ Grillage (For up to 450mmØ RCP Pipe) 870 x 750 x 1300 o.d. HD02-21-ZZZZ-C Type 2 Inlet w/ Grillage (For up to 450mmØ RCP Pipe) 1060 x 1280 x 1170 o.d. HD02-20-ZZZZ-C Type 2 Outlet w/ Grillage (For up to 450mmØ RCP Pipe) 1060 x 1280 x 1170 o.d. HD11-21-ZZZZ-C 11-13 Inlet w/ Grillage (For up to 600mmØ RCP Pipe) 1405 x 2610 x 1525 o.d. HD11-20-ZZZZ-C 11-13 Outlet w/ Grillage (For up to 600mmØ RCP Pipe) 1405 x 2610 x 1525 o.d. HD14-21-ZZZZ-C 14-15 Inlet w/ Grillage (For up to 750mmØ RCP Pipe) 1405 x 2910 x 1725 o.d. HD14-20-ZZZZ-C 14-15 Outlet w/ Grillage (For up to 750mmØ RCP Pipe) 1405 x 2910 x 1725 o.d. HD16-21-ZZZZ-C 16-20 Inlet w/ Grillage (For up to 1200mmØ RCP Pipe) 1405 x 3310 x 2275 o.d. HD16-20-ZZZZ-C 16-20 Outlet w/ Grillage (For up to 1200mmØ RCP Pipe) 1405 x 3110 x 2275 o.d. HD35-20-2000-C 35-30 Custom Headwall Inlet/Outlet (Variable Backwall Width & Height) 2300 x 5010 x 3000 o.d. HDOT-01-DISS-C Custom Three Block Outfall Dissipator Varies HDOT-02-DISS-C Custom V-Notch Weir Outfall Dissipator Varies HDZZ-GH-HAND-C Headwall Handrail Varies HD00-ZZ-FISH-C Fish Ladder 1400 x 900 x 1250

Transcript of May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in...

Page 1: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Tel (604) 576-1808 aeconcrete.com

May 2017

Sales Office: Shipping: Page 1

19060-54th Avenue, Surrey, B.C. Canada V3S 8E5 5353-192nd Street, Surrey, B.C. Canada V3S 8E5

Headwall Listings Drawing Number Item Description Product Size

(Length X Width X Depth in mm)

HDSP-21-ZZZZ-C Highways 16-SP 219 w/ Grillage, MOTH Dwg# SP582-04.01

(For up to 450mmØ RCP Pipe) 1280 x 920 x 1530 o.d.

HD01-21-ZZZZ-C Type 1 Inlet w/ Grillage

(For up to 450mmØ RCP Pipe) 870 x 750 x 1300 o.d.

HD02-21-ZZZZ-C Type 2 Inlet w/ Grillage

(For up to 450mmØ RCP Pipe) 1060 x 1280 x 1170 o.d.

HD02-20-ZZZZ-C Type 2 Outlet w/ Grillage

(For up to 450mmØ RCP Pipe) 1060 x 1280 x 1170 o.d.

HD11-21-ZZZZ-C 11-13 Inlet w/ Grillage

(For up to 600mmØ RCP Pipe) 1405 x 2610 x 1525 o.d.

HD11-20-ZZZZ-C 11-13 Outlet w/ Grillage

(For up to 600mmØ RCP Pipe) 1405 x 2610 x 1525 o.d.

HD14-21-ZZZZ-C 14-15 Inlet w/ Grillage

(For up to 750mmØ RCP Pipe) 1405 x 2910 x 1725 o.d.

HD14-20-ZZZZ-C 14-15 Outlet w/ Grillage

(For up to 750mmØ RCP Pipe) 1405 x 2910 x 1725 o.d.

HD16-21-ZZZZ-C 16-20 Inlet w/ Grillage

(For up to 1200mmØ RCP Pipe) 1405 x 3310 x 2275 o.d.

HD16-20-ZZZZ-C 16-20 Outlet w/ Grillage

(For up to 1200mmØ RCP Pipe) 1405 x 3110 x 2275 o.d.

HD35-20-2000-C 35-30 Custom Headwall Inlet/Outlet

(Variable Backwall Width & Height) 2300 x 5010 x 3000 o.d.

HDOT-01-DISS-C Custom Three Block Outfall Dissipator Varies

HDOT-02-DISS-C Custom V-Notch Weir Outfall Dissipator Varies

HDZZ-GH-HAND-C Headwall Handrail Varies

HD00-ZZ-FISH-C Fish Ladder 1400 x 900 x 1250

Page 2: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

1280

550

GalvanizedGrillage

Plan View

Front View

610

920

Section

865

330

300

750

150

1530

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Highways 16-SP219 Inlet(For up to 450mmØ RCP / 2003 MoT Dwg# SP582-04.01 Inlet)

Headwall: 4,860 lbs / 2,210 kgs 1:20 mm 28Jul08

HDSP-21-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 3: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

1200

480

GalvanizedGrillage

Plan View

Front View

540

Section

100

800

630

100

400

680 830

1300

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Type 1 Inlet(For up to 450mmØ RCP)

Headwall: 1,950 lbs / 885 kgs 1:20 mm 28Jun08

HD01-21-ZZZZ-C

Page 4: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Plan View

Section

1020

Galvanized Grillage

900

270

70

470

630

1170

Front View

1260

100960570

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Type 2 Inlet(For up to 450mmØ RCP)

Headwall: 2,240 lbs / 1,020 kgs 1:20 mm 28Jun08

HD02-21-ZZZZ-C

Page 5: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Galvanized Grillage

Plan View

Front View Section

1020

1060

110

70

470

630

1170

1255

570 960 100

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Type 2 Outlet(For up to 450mmØ RCP)

Headwall: 2,240 lbs / 1,020 kgs 1:20 mm 28Jun08

HD02-20-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 6: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

1405

150

2610

12551100

200

200

1325

Plan View

Front View Section

150GalvanizedGrillage

1125

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

11-13 Inlet(For up to 600mmØ RCP)

Headwall: 6,700 lbs / 3,040 kgsGrillage: 100 lbs / 45 kgs

1:30 mm 28Jun08

HD11-21-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 7: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Plan View

Front View Section

GalvanizedGrillage

2610

1100

1125

400

150

1405

200

200

525

600

1525

500 755 150

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

11-13 Outlet(For up to 600mmØ RCP)

Headwall: 6,570 lbs / 2,990 kgsGrillage: 52 lbs / 24 kgs

1:30 mm 28Jun08

HD11-20-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 8: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

1405

Plan View

Front View

2910

1400

Section

150

GalvanizedGrillage

150

13251525

1255

200

200

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

14-15 Inlet(For up to 750mmØ RCP)

Headwall: 8,630 lbs / 3,915 kgsGrillage: 169 lbs / 77 kgs

1:30 mm 15Jul15

HD14-21-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 9: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Plan View

Front View Section

1255 150GalvanizedGrillage1400

2910

1325

200

200

1525

150

1405

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

14-15 Outlet(For up to 750mmØ RCP)

Headwall: 8,630 lbs / 3,915 kgsGrillage: 84 lbs / 38 kgs

1:30 mm 15Jul15

HD14-20-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 10: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

GalvanizedInlet Grillage

3110

200

200

1875

1600

Plan View

Front View Section

150

150

1405

1255

2075

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

16-20 Inlet(For up to 1200mmØ RCP)

Headwall: 11,130 lbs / 5,050 kgsGrillage: 244 lbs / 111 kgs

1:30 mm 28Jun08

HD16-21-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 11: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

GalvanizedGrillage

150

1255

2075

14053110

1875

Plan View

Front View

1600

Section

150

200

200

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

16-20 Outlet(For up to 1200mmØ RCP)

Headwall: 11,130 lbs / 5,050 kgsGrillage: 106 lbs / 48 kgs

1:30 mm 28Jun08

HD16-20-ZZZZ-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 12: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Flap Gate and Galvanized Inletor Outlet GrillageAvailable

300755 1100 - 3500 755

1800 - 2860

Opening Size, Quantity & Location to Suit

2000

Plan View

Section

150

Front View

200 - 300

200

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

35-29 Custom Headwall Inlet/Outlet

(Variable Backwall Width and Height)

1:40 mm 22Jul14

HD35-20-2000-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 13: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

1/2 Pipe Ø

150

2/3 Pipe Ø

4501/2 Pipe Ø

450Pipe Ø

Plan View

Front View Section

GalvanizedGrillage

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Custom Three Block Outfall Dissipator(11-13, 14-15, 16-20)

1:30 mm 28Jun08

HDOT-01-DISS-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 14: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Plan View

Front View Section

GalvanizedGrillage

2/3 Pipe Ø

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Custom V-Notch Weir Outfall Dissipator(11-13, 14-15, 16-20)

1:30 mm 28Jun08

HDOT-02-DISS-C

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Custom Pipe Openings Available

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Page 15: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

H

Side View

Plan View

1070

535

535

1070

Galvanized48mm O.D. Handrail

Mounting Base PlateTyp

1724

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Headwall Handrail(11-13, 14-15, 16-20)

1:20 mm 12Jun13

HDZZ-GH-HAND-C

General Notes:

⋅ Steel Products manufactured under CSA W47.1 in accordance to CSA W59

⋅ Site Installation is the responsibility of others

Page 16: May 2017 Headwall Listings - aeconcrete.com · ⋅Steel Products manufactured under CSA W47.1 in accordance to CSA W59 ⋅Site Installation is the responsibility of others. Plan View

Plan View

Side View End View

600

1100

910

1410

1250

750

450

960

1060

300 300

700

100

1350

General Notes:

⋅ Product manufactured in accordance with CSA A23.4

⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)

⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others

Dwg#:

Rev:Scale:

19060 - 54th AvenueSurrey, B.C. V3S 8E5

Tel (604) [email protected]

Fish Ladder

Sump: 2,950 lbs / 1,340 kgs 1:20 mm 21Jul14

HD00-ZZ-FISH-C