MAXRaft Brochure
-
Upload
henry-edney -
Category
Documents
-
view
54 -
download
3
Transcript of MAXRaft Brochure
• Healthy,comfortablehomes.
• Reducedheatinganddoctors’bills.
• FullyinsulatedwithaverageR-valueofapproximatelyR4.5
• Minimalthermalbridging.
• Minimalsiteworksleadtoreducedcosts.
• Lesstimeonsite
• Seismicallystrong.
• Sitespecificengineering.
• Capableonsoilswithaminimumallowablebearingcapacityof75kPa.
• UPto30%-40%efficiencygainsforunderfloorheating
“Onastandardflatsection220m2house,wecanexcavateonaMonday,andbyFriday,beplacingtheconcrete,readyforframestobeerectedonMonday–oneweekturnaround.MAXRaft®issimplythequickestandmostefficientbuildingmethodforaconcreteflooronthemarkettoday,letaloneitsexcellentthermalefficiencywhichisitsmainadvantage.Ibelievethisisthewayofthefuture.”- David Reid Homes
Phone:0800MAXRaft(629723)Christchurch:027MAXRaft(6297238)Email:[email protected]:[email protected]
“HavingmadethedecisiontoinstallunderfloorheatinginmynewhomeIknewfrompreviousexperiencethatIwantedafullyinsulatedfoundationtopreventheatloss.AfterabitofsearchingaroundIcameacrossMAXRaftandknewstraightawayitwasexactlywhatIwaslookingfor.CombiningMAXRaftwithaheatedslabhasgivenmeawarmhomeineveryroomallyearroundandthebestthingismypowerbillsarealotlowerthanmanypeopleIknow.Duringwinterthecostofmyhydronicheatinghasaveraged60.8cperm2permonth!WhenIbuildmynexthomeIwilldefinitelybeusingafullyinsulatedslabagain”- Terry Robb
“InourexperienceMAXRaftisoneofthemostefficientwaysofpreppingaconcreteslabthananyothersystem.ThereislimitedbracingandboxingrequiredastheMAXRaftisprefabricatedinthefactoryanddeliveredontositereadytobeinstalled.ItsratingisaR4.5whichmakesanybuildingusingitextremelywellinsulated.Highlyrecommended.”- Evolution Homes
BENEFITS TESTIMONIALS
CONTACT US
TM
Know your home
MAXRaft® is changing the way people think about foundations. Build Better today for a better tomorrow.
Witheverydesign,wearehelpingpeopleliveinwarmer,healthier,moreefficienthomes.
eboss
• ExcavatebuildingsitetoappropriatelevelinlinewithGeotechandEngineer’srecommendations,compactingandbackfillingasnecessary.
• Levelthesiteusingalayeroffinescreed,putupboxingaroundperimeter
• Laydampproofmembraneoverentirebuildingplatform,ensurethereisenoughmaterialtoextend100mmoutsidethefoundation.Ensureunderfloordrainsaretapedup
• ReceivedeliveryofMAXRaftinsulation.Placepre-cutMAXRaftinsulationinlinewithPanelplan,followPanelplandirectlytoensurethatloadbearingthickeningsandthermalbreaksareincorrectplace
• Placereinforcingsteel(designedinlinewithengineer’sspecifications)inperimeterfootingwells.Underfloorheatingcanbeinstalledatthisstage,dependingoninstaller’srequirements.
• PlacereinforcingmeshontopoftheMAXRaft.Tiemeshtoreinforcingaroundperimeterandbeneathloadbearingwalls.
• Placingfinishedconcretetospecifications.
• EnjoythewarmthandcomfortcreatedwithaMAXRaftfloor.
CONSTRUCTION PROCESS
D1 © - 01
SheetTitle
Drawn
Revision
Scale @ A4
ProjectNumber.
Date
DrawingNumber.
Project
MAXRaft© Detailswww.maxraft.co.nzCWL 20/61:10
0D1
MAXRaft 90x45 Frame Foundation
Note:Prop wall while backfilling untilsuspended floor is poured and cured.
100
250
1200
200
Polyblock waterproofedand back filled as perarchitects details
MAXRaft on DPM, sandblinding and solidcompaction
Polyblock braced as permanufacturers details
Reinforcing as perEngineers details
D5 MAXRaft© - RetainingWall Foundation01
280
100
MAXSpan
SheetTitle
Drawn
Revision
Scale @ A4
ProjectNumber.
Date
DrawingNumber.
Project
MAXRaft© Detailswww.maxraft.co.nzCWL 20 / 61:20
0D5
MAXRaft Retaining Foundation
D4
Concrete & reinforcing as per engineers details
Supercoat tanking system asper manufacturers details
Cladding by others.
NOTE:150mm min clearance fromslab level to exterior paving,225mm min clearance fromslab level to unpaved groundto E2/AS1.
300
25
Solid compaction1000mm pastfoundation line
MAXWaffleRaft© - Timber Framewith Lightweight cladding01
Timber framed wall with bottom plate fixing toMaxRaft Specification
100
170
50
320
50
MaxWaffleRaft
Compacted hard fill orsimilar by others, min200 kPa Ultimate bearingstrength at formation.Refer to MIBE (2012)guidelines for building inTC2 locations.
1100 120
She
etTi
tleD
raw
n
Rev
isio
n
Sca
le @
A4
Pro
ject
Num
ber.
Dat
e
Dra
win
gN
umbe
r.
Pro
ject
MA
XR
aft©
Det
ails
ww
w.m
axra
ft.co
.nz
CW
L20
/ 6
N T
S
0D4
MA
XR
aft W
affle
Fou
ndat
ion
01D2 © -
SheetTitle
Drawn
Revision
Scale @ A4
ProjectNumber.
Date
DrawingNumber.
Project
MAXRaft© Detailswww.maxraft.co.nzCWL 20 / 61:10
0D2
MAXRaft Loadbearing Foundation
Ourperimeterfootingsaredesignedtomaintainheatintheslabattheexactpointwhereupto80%ofheatlossintheslaboccurs.Thisensuresthatthefloor/walljunctureremainswarm,dryandmouldfree,increasingcomfortandloweringpossiblehealthissues.
Thermalbridgefreeconstructionisessentialforperimeterfoundationstoensurethereisnocondensationriskandoptimalthermalcomfort.
Aconventionalwaffleslabfloorhasmanythermalbridgesespeciallyaroundtheperimeter.
AcomparisonstudybetweentheperimeterfoundationofatraditionalwaffleslabandafullyInsulatedfootingassumingstandardtimberwallconstruction.
CopyrighteZEDLtd
• MAXSpandeliversthebenefitsofMAXRaft®totheupperlevelsofyourhome.
• Suitableforuseonmulti-storeybuildings,abovebasementsoroninclinesites,MAXSpanwillallowyoutouseaconcretefloorabovethefoundation.
MAXRaft®offersacontinuouslayerofperimeterinsulation.Thishasadramaticeffectonthesurfacetemperatureattheflooredge.
Ouriso-thermalanalysismakesiteasytoseethedifferenceinsurfacetemperature.
• MAXRaftcanbeusedinconjunctionwithretainingwallsandsoisnotlimitedtouseonjustflatsites.Ourengineerscanprovidedesignsthatwillallowyoutomaintainafullyinsulatedslabwhilealsoprovidingthestrengthneededtoprotectyourhomefromgroundaroundit
MAXWaffleRaftisdesignedtocomplywithDBHguidelinesforbuildingsonTC2landcategoriesandthosesitesongroundof‹100kPa,whilestillmaintainingathermalenvelopearoundyourhome.
Ourloadbearingthickeningsaredesignedsupportloadbearingwallswithinyourhomewhilemaintainingacompletethermalenvelopearoundyourfoundation.
NZS3604/TC1 MAXRaft Perimeter Footing
Traditional Waffle Slab
MAXSpan
MAXRaft® Slab
Retaining walls
MAXWaffleRaft / TC2 Solution
Internal Thickenings / Tie Beams