maxon EC (BLDC) motor The electronically commutated EC motors are characterized especially by their favorable torque characteristics, high power, extremely broad speed range and, of course, by their unsurpassed service life.
Standard Specification No. 101 168Explanation of the EC motors 169 EC Program 170–196EC-max Program 199–207EC-4pole Program 211–216EC flat Program 218–237
X D
rive
s(c
onfig
urab
le)
DC
Moto
r E
C M
oto
r(B
LDC
Mot
or)
Gearh
ead
Spin
dle
dri
veSenso
r M
oto
r
contr
ol
Com
pact
Dri
veA
ccess
ori
es
Cera
mic
max
on
EC
mo
tor
170
6 1244600 3400038.6 13.5
24300 132000.354 0.3390.324 0.1190.813 0.5850.673 0.187
59 54
8.92 640.065 0.4361.21 3.127900 3060
58300 626004.29 4.61
0.00703 0.00703
M 2.5:1
73.7 K/W 5.6 K/W 0.564 s 78.9 s -20...+100°C +125°C
< 0.15 N 0 mm > 0.15 N max. 0.06 mm
0.1 N 10 N 2 N
1 3 3 g
455020 468897455019 468896
455020
1.5 W
0.30.15 0.45 0.6
ESCON 36/3 EC 342 ESCON Mod. 50/4 EC-S 343DEC Module 24/2 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 6 ∅6 mm, brushless, 1.5 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 100 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) 28 Max. radial load, 2 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection with hall sensors sensorless Pin 1 Motor winding 1 Motor winding 1 Pin 2 Motor winding 2 Motor winding 2 Pin 3 Motor winding 3 Motor winding 3 Pin 4 VHall 3.8...24 VDC N.C. Pin 5 GND Pin 6 Hall sensor 1 Pin 7 Hall sensor 2 Pin 8 Hall sensor 3 Connector Part number Part number Molex 52745-0897 52207-0433 Molex 52089-0419 Tyco 84953-4 FCI SFV8R-2STE1LF Pin for design with Hall sensors: FPC, 8 pole, pitch 0.5 mm, top contact style Wiring diagram for Hall sensors see page 33
Planetary Gearhead∅6 mm0.002 - 0.03 NmPage 242
Motor Data (provisional)
A with Hall sensorsB sensorless
Spindle Drive∅6 mmPage 293
Recommended Electronics: Page
Notes 24
171171
max
on
EC
mo
tor
3 6 1265400 55600 56300
124 49.7 25.137600 38200 410000.481 0.475 0.491.25 0.519 0.2691.18 1.58 1.872.82 1.58 0.94763 68 71
1.07 3.79 12.70.005 0.03 0.1180.418 0.997 1.9822800 9570 483058200 36400 309004.28 2.68 2.27
0.00703 0.00703 0.00703
M 2.5:1
65.8 K/W 13.2 K/W 1.34 s 70.4 s -20...+100°C +125°C
< 0.15 N 0 mm > 0.15 N max. 0.06 mm
0.1 N 10 N 2 N
1 3 3 g
455417 455418 455419455420 455421 455422
455417
2.0 W
0.5 0.1 1.5
0.1 0.2 0.3 0.4 0.5
ESCON 36/3 EC 342 ESCON Mod. 50/4 EC-S 343DEC Module 24/2 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25Planetary Gearhead∅6 mm0.002 - 0.03 NmPage 242Spindle Drive∅6 mmPage 293
EC 6 ∅6 mm, brushless, 2 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 100 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) 28 Max. radial load, 2 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection with hall sensors sensorless Pin 1 Motor winding 1 Motor winding 1 Pin 2 Motor winding 2 Motor winding 2 Pin 3 Motor winding 3 Motor winding 3 Pin 4 VHall 3.8...24 VDC N.C. Pin 5 GND Pin 6 Hall sensor 1 Pin 7 Hall sensor 2 Pin 8 Hall sensor 3 Connector Part number Part number Molex 52745-0897 52207-0433 Molex 52089-0419 Tyco 84953-4 FCI SFV8R-2STE1LF Pin for design with Hall sensors: FPC, 8 pole, pitch 0.5 mm, top contact style Wiring diagram for Hall sensors see page 33
Motor Data (provisional)
A with Hall sensorsB sensorless
Recommended Electronics: Page
Note 24
max
on
EC
mo
tor
172
6 12 2435900 43800 4270069.2 46 22.1
24000 32800 320000.977 0.942 0.9440.691 0.41 0.23.05 3.9 3.931.98 1.54 0.75567 69 70
3.02 7.8 31.80.039 0.106 0.4471.54 2.53 5.216200 3770 183012200 11600 112003.19 3.03 2.92
0.024961 0.024961 0.024961
M 2.5:1
468334
2.0 W
0.5 1.0
468334 468335 468336468337 468338 468339
51.2 K/W 3.5 K/W 0.832 s 154 s -20…+100°C 125°C
< 0.15 N 0 mm > 0.15 N max. 0.06 mm
0.1 N 10 N 2 N
1 3 6 g
ESCON 36/3 EC 342 ESCON Mod. 50/4 EC-S 343DEC Module 24/2 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 8 ∅8 mm, brushless, 2 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings) 23 Max. speed 80 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) 28 Max. radial load, 2 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection with hall sensors sensorless Pin 1 Motor winding 1 Motor winding 1 Pin 2 Motor winding 2 Motor winding 2 Pin 3 Motor winding 3 Motor winding 3 Pin 4 VHall 3.8...24 VDC N.C. Pin 5 GND Pin 6 Hall sensor 1 Pin 7 Hall sensor 2 Pin 8 Hall sensor 3 Connector Part number Part number Molex 52745-0897 52207-0433 Molex 52089-0419 Tyco 84953-4 Pin for design with Hall sensors: FPC, 8 pole, pitch 0.5 mm, top contact style Wiring diagram for Hall sensors see page 33
Planetary Gearhead∅8 mm0.01 - 0.1 NmPage 243
Motor Data
Recommended Electronics: Page
Notes 24
A with hall sensors B sensorless
A with Hall sensorsB sensorless
Spindle Drive∅8 mmPage 294–295
173173
max
on
EC
mo
tor
6 9 12 1849200 52500 53200 57100
160 118 90.4 67.341700 45600 46600 509001.74 1.63 1.62 1.611.66 1.11 0.843 0.612 13 13.7 15.6
10.4 8.05 6.46 5.2777 78 78 79
0.575 1.12 1.86 3.420.00998 0.0198 0.0342 0.0671
1.15 1.61 2.12 2.978340 5920 4500 32204180 4110 3940 37003.03 2.97 2.85 2.68
0.0691 0.0691 0.0691 0.0691
M 1:1
315170 315171 315172 315173315174 315175 315176 315177
8.0
20000
40000
60000
0.5 1.0 1.5 2.0
1.00.5 1.5 2.0
315170
1.5
39.8 K/W 5.1 K/W 1.51 s 221 s -40…+100°C +125°C
< 1.0 N 0 mm > 1.0 N max. 0.14 mm
0.8 N 12 N
250 N 2 N
1 3 13 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343 ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346 DEC Module 50/5 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 10 ∅10 mm, brushless, 8 Watt
Motor DataValues at nominal voltage
1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 65 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static)
(static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection with Hall sensors sensorless Pin 1 VHall 4.5…24 VDC Motor winding 1 Pin 2 Hall sensor 3 Motor winding 2 Pin 3 Hall sensor 1 Motor winding 3 Pin 4 Hall sensor 2 N.C. Pin 5 GND Pin 6 Motor winding 3 Pin 7 Motor winding 2 Pin 8 Motor winding 1 Adapter Part number Part number see p. 362 220300 220310 Connector Part number Part number Tyco 1-84953-1 84953-4 Molex 52207-1133 52207-0433 Molex 52089-1119 52089-0419 Pin for design with Hall sensors: FPC, 11-pol, Pitch 1.0 mm, top contact style
Planetary Gearhead∅10 mm0.01 - 0.15 NmPage 245
Recommended Electronics: Page
Notes 24
A with Hall sensors B sensorless
A with Hall sensorsB sensorless
max
on
EC
mo
tor
174
6 9 12 18 2428800 30600 27500 27900 27700
168 121 78.6 53.5 39.820200 22700 19500 19700 194002.23 2.36 2.32 2.24 2.211.31 0.976 0.646 0.425 0.3127.79 9.53 8.27 8 7.724.08 3.52 2.06 1.35 0.97364 67 65 65 64
1.47 2.56 5.82 13.3 24.70.021 0.042 0.091 0.198 0.3571.91 2.71 4.01 5.92 7.945000 3520 2380 1610 12003850 3330 3460 3630 37407.83 6.76 7.02 7.38 7.590.194 0.194 0.194 0.194 0.194
M 1:1
6.050000
10000
20000
30000
40000
0.5 1.0 1.5
1.0 2.0
416184
416184 430152 430153 430154 430155426333 430156 430157 430158 430159
32 K/W 2.46 K/W 0.72 s 188 s -40…+100°C +155°C
< 1.5 N 0 mm > 1.5 N max. 0.05 mm
1 N 18 N 250 N 4 N
1 3 19 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346 DEC Module 50/5 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 13 ∅13 mm, brushless, 6 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 50 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor Values listed in the table are nominal. Connection with Hall sensors sensorless Pin 1 VHall 4.5…24 VDC Motor winding 1 Pin 2 Hall sensor 3 Motor winding 2 Pin 3 Hall sensor 1 Motor winding 3 Pin 4 Hall sensor 2 N.C. Pin 5 GND Pin 6 Motor winding 3 Pin 7 Motor winding 2 Pin 8 Motor winding 1 Adapter Part number Part number see p. 362 220300 220310 Connector Part number Part number Tyco 1-84953-1 84953-4 Molex 52207-1133 52207-0433 Molex 52089-1119 52089-0419 Pin for design with Hall sensors: FPC, 11-pol, Pitch 1.0 mm, top contact style
Planetary Gearhead∅13 mm0.2 - 0.35 NmPage 248
Motor Data
Recommended Electronics: Page
Notes 24
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
175175
max
on
EC
mo
tor
6 9 12 18 24 3624100 24200 24100 24900 24100 26600198 132 98.9 68.9 49.5 38.2
18200 19100 18800 20000 19000 217005.15 5.64 5.13 5.53 5.18 5.382.37 1.72 1.18 0.871 0.598 0.45621.7 27.4 23.8 28.8 24.8 30.39.31 7.85 5.1 4.24 2.67 2.3874 76 75 77 75 77
0.644 1.15 2.35 4.24 9 15.10.0103 0.0233 0.0413 0.0879 0.165 0.3082.33 3.49 4.66 6.8 9.32 12.74100 2730 2050 1410 1020 7511130 896 1030 877 990 8933.86 3.05 3.52 2.99 3.37 3.040.325 0.325 0.325 0.325 0.325 0.325
M 1:1
1250000
10000
20000
30000
40000
1.0 2.0 3.0
1.0 3.0
426397
6.0
426397 430160 430161 430162 430163 430164426576 430166 430167 430168 430169 430170
23.9 K/W 1.26 K/W 0.603 s 263 s -40…+100°C +155°C
< 1.5 N 0 mm > 1.5 N max. 0.05 mm
0.8 N 18 N
250 N 4 N
1 3 29 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346 DEC Module 50/5 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 13 ∅13 mm, brushless, 12 Watt
Motor DataValues at nominal voltage
1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient18 Thermal resistance winding-housing19 Thermal time constant winding20 Thermal time constant motor21 Ambient temperature22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 50 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic)27 Max. force for press fits (static)
(static, shaft supported)28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs30 Number of phases31 Weight of motor
Connection with Hall sensors sensorless Pin 1 VHall 4.5…24 VDC Motor winding 1 Pin 2 Hall sensor 3 Motor winding 2 Pin 3 Hall sensor 1 Motor winding 3 Pin 4 Hall sensor 2 N.C. Pin 5 GND Pin 6 Motor winding 3 Pin 7 Motor winding 2 Pin 8 Motor winding 1 Adapter Part number Part number see p. 362 220300 220310 Connector Part number Part number Tyco 1-84953-1 84953-4 Molex 52207-1133 52207-0433 Molex 52089-1119 52089-0419 Pin for design with Hall sensors: FPC, 11-pol, Pitch 1.0 mm, top contact style
Planetary Gearhead∅13 mm0.2 - 0.35 NmPage 248
Recommended Electronics: Page
Notes 24
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
max
on
EC
mo
tor
176
12 24 4865300 65300 76000
171 85.5 53.959100 59400 70200
5 4.99 4.472.99 1.49 0.78860.2 64.3 68.234.5 18.4 11.487 87 87
0.348 1.3 4.220.018 0.072 0.2131.75 3.49 65470 2740 15901090 1020 11201.63 1.53 1.680.143 0.143 0.143
M 1:1
30100000
20000
40000
60000
80000
1.0 2.0 4.0
1.0 2.0 4.0
448825
5.0
3.0
3.0
448825 448826 448827448831 448832 448833
20.7 K/W 2.58 K/W 1.87 s 391 s -40…+135°C +155°C
< 7 N 0 mm > 7 N max. 0.1 mm
6 N 10 N 4 N
1 3 37.8 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346DEC Module 50/5 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 13 ∅13 mm, brushless, 30 Wattsterilizable
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 90 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Alignment of the electronic connections not specified.
Values listed in the table are nominal.
Connection A and B, motor (cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors (cable AWG 26) green VHall 3.8...24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3
Option: Inch-version size 5 available as standard version.
Planetary Gearheadsterilizable∅13 mm0.05 - 0.275 NmPage 249
Motor Data (provisional)
Recommended Electronics: Page
Notes 24Choke may be required
A with Hall sensorsB sensorless
maxon modular system Overview on page 20–25
Application Sterilization information
Sterilizable Devices Tested for 1000 sterilization cycles in an autoclave.
No need to dismantle.
Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
177177
max
on
EC
mo
tor
177
12 24 4873400 73400 73500
270 135 67.668000 68800 690007.76 8.05 8.045.2 2.69 1.34120 151 15877.3 48.6 25.589 90 90
0.155 0.494 1.890.00676 0.027 0.108
1.55 3.11 6.226140 3070 1540613 488 4652.31 1.84 1.750.36 0.36 0.36
M 1:1
50100000
20000
40000
60000
80000
1.0 4.0 5.0
3.0 6.0 9.0
448829
2.0 3.0
448828 448829 448830448834 448835 448836
17.9 K/W 0.703 K/W 0.693 s 394 s -40…+135°C +155°C
< 7 N 0 mm > 7 N max. 0.85 mm
6 N 7 N 4 N
1 3 44 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346DEC Module 50/5 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 13 ∅13 mm, brushless, 50 Wattsterilizable
Thermal data 17 Thermal resistance housing-ambient18 Thermal resistance winding-housing19 Thermal time constant winding20 Thermal time constant motor21 Ambient temperature22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 90 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic)27 Max. force for press fits (static)28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs30 Number of phases31 Weight of motor
Alignment of the electronic connections not specified.
Values listed in the table are nominal.
Connection A and B, motor (cable AWG 22) red Motor winding 1
black Motor winding 2 white Motor winding 3 Connection A, sensors (cable AWG 26) green VHall 3.8...24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3
Option: Inch-version size 5 available as standard version.
Motor Data (provisional)
A with Hall sensorsB sensorless
maxon Modular System Overview on page 20–25Planetary Gearheadsterilizable∅13 mm0.05 - 0.275 NmPage 249
Recommended Electronics: Page
Notes 24Choke may be required
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Application Sterilization information
Sterilizable Devices Tested for 1000 sterilization cycles in an autoclave.
No need to dismantle.
Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
max
on
EC
mo
tor
178
12 18 24 36 4844500 42200 42800 45800 39600
397 241 185 139 80.839300 37400 38100 41100 348007.85 8.01 8.09 7.56 7.873.41 2.18 1.68 1.14 0.75475.5 78 82.7 82.3 72.529.8 19.4 15.6 11.1 6.3579 80 80 80 79
0.403 0.928 1.53 3.24 7.560.0235 0.059 0.102 0.2 0.477
2.54 4.02 5.29 7.4 11.43760 2380 1810 1290 836598 549 524 565 5544.54 4.17 3.98 4.29 4.210.725 0.725 0.725 0.725 0.725
M 1:1
3070000
15000
30000
50000
1.0
2.0 6.04.0
400160
3.02.0
400160 405812 400161 405813 400162404079 405817 404080 405818 404081
400160
16.3 K/W 1.68 K/W 1.97 s 240 s -20…+100°C +155°C
< 3.5 N 0 mm > 3.5 N max. 0.14 mm
3 N 35 N 250 N 10 N
1 3 34 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2, 50/5 346EPOS2 24/2, Module 36/2 350EPOS2 24/5, EPOS2 50/5 351EPOS2 P 24/5 354EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 16 ∅16 mm, brushless, 30 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient18 Thermal resistance winding-housing19 Thermal time constant winding20 Thermal time constant motor21 Ambient temperature22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 70 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic)27 Max. force for press fits (static) (static, shaft supported)28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs30 Number of phases31 Weight of motor
Values listed in the table are nominal.
Connection A brown Motor winding 1 Pin 1 red Motor winding 2 Pin 2 orange Motor winding 3 Pin 3 yellow VHall 3…24 VDC Pin 4 green GND Pin 5 blue Hall sensor 1 Pin 6 violet Hall sensor 2 Pin 7 grey Hall sensor 3 Pin 8 Wiring diagram for Hall sensors see p. 33
Connection B (Cable AWG 24) brown Motor winding 1 red Motor winding 2 orange Motor winding 3
Motor Data
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
Connector: 8-pol 2.5 mm z.B. MKF 13268-6-0-808 Stocko Elektronik GmbH
Planetary Gearhead∅16 mm0.1 - 0.6 NmPage 254/255
Recommended Electronics: Page
Notes 24
for type A:Encoder MR128/256/512 CPT,Page 318
Planetary Gearhead∅22 mm0.5 - 1.0 NmPage 262Spindle Drive∅16 mmPage 296–298
179179
max
on
EC
mo
tor
179
12 2447800 45900
323 15342100 408007.66 7.853.51 1.7270.6 77.329.8 15.681 81
0.403 1.530.0168 0.07292.37 4.944030 1930685 6015.2 4.56
0.725 0.725
M 1:1
3070000
15000
30000
50000
1.0
2.0 6.04.0
405146
3.02.0 4.0
405146 405147405149 405150
16.3 K/W 1.68 K/W 1.97 s 240 s -40…+135°C 155°C
< 3.5 N 0 mm > 3.5 N max. 0.14 mm
3 N 43 N 250 N 10 N
1 3 34 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346DEC Module 50/5 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 16 ∅16 mm, brushless, 30 Wattsterilizable
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient18 Thermal resistance winding-housing19 Thermal time constant winding20 Thermal time constant motor21 Ambient temperature22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 70 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic)27 Max. force for press fits (static) (static, shaft supported)28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs30 Number of phases31 Weight of motor
Values listed in the table are nominal.
Connection A and B, motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3
Connection A, sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33
Motor Data
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
maxon modular system Overview on page 20–25Planetary Gearheadsterilizable ∅16 mm0.1 - 0.3 NmPage 256
Recommended Electronics: Page
Notes 24
Application Sterilization information
Sterilizable Devices Tested for 100 sterilization cycles in an autoclave.
No need to dismantle.
Orthopedic Drills & Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
max
on
EC
mo
tor
180
12 18 24 32 4837100 43400 43400 43400 41700327 272 204 153 96.2
32500 39200 39400 39500 3790017.2 16.9 17 17 17.15.82 4.48 3.39 2.54 1.63157 205 221 230 22451.4 52 42.2 32.8 20.585 86 87 87 87
0.233 0.346 0.569 0.976 2.340.02 0.033 0.059 0.104 0.2543.06 3.94 5.25 7 10.93120 2420 1820 1360 873238 213 197 190 1872.66 2.39 2.21 2.13 2.091.07 1.07 1.07 1.07 1.07
M 1:1
6070000
15000
30000
50000
2.0 6.0
8 1612
394216
8.0
4 20
4.0
394216 396916 395588 396928 405794397162 397294 397292 397295 405795
394216
10.3 K/W 1.2 K/W 2.53 s 299 s -20…+100°C 155°C
< 3.5 N 0 mm > 3.5 N max. 0.14 mm
3 N 35 N 250 N 10 N
1 3 58 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2, 50/5 346EPOS2 24/2, Module 36/2 350EPOS2 24/5, 50/5 351EPOS2 P 24/5 354EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 16 ∅16 mm, brushless, 60 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient18 Thermal resistance winding-housing19 Thermal time constant winding20 Thermal time constant motor21 Ambient temperature22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 70 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic)27 Max. force for press fits (static) (static, shaft supported)28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs30 Number of phases31 Weight of motor
Values listed in the table are nominal.
Connection A brown Motor winding 1 Pin 1 red Motor winding 2 Pin 2 orange Motor winding 3 Pin 3 yellow VHall 3…24 VDC Pin 4 green GND Pin 5 blue Hall sensor 1 Pin 6 violet Hall sensor 2 Pin 7 gray Hall sensor 3 Pin 8 Wiring diagram for Hall sensors see p. 33 Connection B (Cable AWG 24) brown Motor winding 1 red Motor winding 2 orange Motor winding 3
Motor Data
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
Recommended Electronics: Page
Notes 24
for type A:Encoder MR128/256/512 CPT,Page 318
Planetary Gearhead∅22 mm0.5 - 1.0 NmPage 262
Spindle Drive∅16/22 mmPage 296–300
Planetary Gearhead∅22 mm0.5 - 2.0 NmPage 265
Planetary Gearhead∅16 mm0.2 - 0.6 NmPage 255
Connector: 8-pol 2.5 mm z.B. MKF 13268-6-0-808 Stocko Elektronik GmbH
181181
max
on
EC
mo
tor
181
12 2447700 55200406 247
42500 5070014.7 14.26.48 3.63147 20261.8 48.985 86
0.194 0.4910.00968 0.0291
2.38 4.134000 2310326 2753.66 3.081.07 1.07
M 1:1
6070000
15000
30000
50000
1.0 3.0 5.0
5 10 157.5
399264
7.0
2.5 12.5
399264 399263399696 399678
10.3 K/W 1.2 K/W 2.18 s 299 s -40…+135°C 155°C
< 3.5 N 0 mm > 3.5 N max. 0.14 mm
3 N 43 N 250 N 10 N
1 3 58 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344DEC Module 24/2 346DEC Module 50/5 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 16 ∅16 mm, brushless, 60 Wattsterilizable
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 70 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A and B, motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33
Motor Data
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
maxon modular system Overview on page 20–25Planetary Gearheadsterilizable ∅16 mm0.1 - 0.3 NmPage 256
Recommended Electronics: Page
Notes 24
Application Sterilization information
Sterilizable Devices Tested for 100 sterilization cycles in an autoclave.
No need to dismantle.
Orthopedic Drills & Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
max
on
EC
mo
tor
182
18 24 30 3667100 69600 65200 67000406 324 232 203
63600 66100 61700 6350011.8 11.6 12.2 11.34.92 3.78 2.96 2.37335 358 334 308131 109 76.3 60.589.4 89.6 89.5 88.9
0.137 0.22 0.393 0.5950.0224 0.037 0.0658 0.08962.55 3.28 4.37 5.13740 2910 2180 1870201 195 196 2183.46 3.35 3.37 3.751.64 1.64 1.64 1.64
M 1:1
60 W
20000
40000
60000
80000
1.5 4.3
5 10 15
475529
2.9
475529 475530 474510 477254
10.7 K/W 0.81 K/W 2.67 s 426 s -20…+100°C 120°C
< 3 N 0 mm > 3 N max. 0.14 mm
3 N 22 N 1410 N 12 N
1 3 80 g
ESCON Mod. 50/4 EC-S 343
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 19 ∅19 mm, brushless, 60 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 80 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3
Motor Data (provisional)
Recommended Electronics:
Notes 24
sensorless
183183
max
on
EC
mo
tor
24 30 3662200 60500 54400
272 208 14759200 57600 5160023.5 24.1 24.56.61 5.25 3.99589 610 559160 129 88.792 92.2 92.1
0.15 0.233 0.4060.010 0.017 0.0303.68 4.73 6.312600 2020 1510106 99.3 97.52.01 1.88 1.851.81 1.81 1.81
M 1:1
120 W100000
20000
40000
60000
80000
1.7 6.4 7.9
5 10 15
475523
3.2 4.8
20
475523 475524 467392475527 475528 474494
10.7 K/W 0.81 K/W 2.67 s 437 s -20…+100°C 155°C
< 3 N 0 mm > 3 N max. 0.14 mm
3 N 22 N 1410 N 12 N
1 3 82 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5, 70/10 344DEC Module 24/2, 50/5 346
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 19 ∅19 mm, brushless, 120 WattHigh Power
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 100 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A and B, motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33
Motor Data (provisional)
Recommended Electronics: Page
Notes 24
A with Hall sensorsB sensorless
max
on
EC
mo
tor
184
24 30 3662200 60500 54400
272 208 14759400 57700 5170022.5 24 24.56.35 5.24 3.99593 646 578161 137 91.692 92.4 92.2
0.149 0.22 0.3930.0103 0.017 0.03023.68 4.73 6.312600 2020 1510105 93.8 94.41.99 1.78 1.791.81 1.81 1.81
M 1:1
475521 475522 467168475525 475526 474493
10.7 K/W 0.808 K/W 2.46 s 437 s -40…+135°C 155°C
< 3 N 0 mm > 3 N max. 0.14 mm
3 N 22 N 1410 N 12 N
1 3 82 g
120 W100000
20000
40000
60000
80000
1.1 4.1 5.1
5 10 15
475521
2.1 3.1
20
ESCON 36/3 EC 342 ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344ESCON 70/10 344DEC Module 24/2, 50/5 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 19 ∅19 mm, brushless, 120 WattHigh Power, sterilizable
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 100 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A and B, motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33
Motor Data (provisional)
A with Hall sensorsB sensorless
Planetary Gearheadsterilizable ∅19 mm0.5 - 2.0 NmPage 258
Recommended Electronics: Page
Notes 24
maxon modular system Overview on page 20–25
Application Sterilization information
Sterilizable Devices Tested for 1000 sterilization cycles in an autoclave.
No need to dismantle.
Orthopedic Drills & Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
185185
max
on
EC
mo
tor
12 24 36 4830400 35100 31600 34100
330 205 116 98.326700 31800 28400 3100020.4 20 19.9 19.55.7 3.25 1.93 1.54184 243 221 23749.1 37.4 20.4 17.785 86 86 86
0.244 0.641 1.76 2.710.0182 0.0546 0.152 0.2313.75 6.49 10.8 13.32550 1470 882 716166 145 144 1454.16 3.64 3.6 3.642.39 2.39 2.39 2.39
M 1:1
4060000
15000
30000
45000
1.0 2.0 3.0
5 15 2010
386658
4.0
386657 386658 386659 386660386661 386662 386663 386664
10 K/W 2 K/W 4.85 s 278 s -20…+100°C +155°C
< 4.5 N 0 mm > 4.5 N max. 0.14 mm
4 N 45 N 250 N 16 N
1 3 85 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5, 70/10 344DEC Module 24/2, 50/5 346EPOS2 24/2, Module 36/2 350EPOS2 24/5, 50/5, 70/10 351EPOS2 P 24/5 354EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 22 ∅22 mm, brushless, 40 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 60 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A brown Motor winding 1 Pin 1 red Motor winding 2 Pin 2 orange Motor winding 3 Pin 3 yellow VHall 3…24 VDC Pin 4 green GND Pin 5 blue Hall sensor 1 Pin 6 violet Hall sensor 2 Pin 7 grey Hall sensor 3 Pin 8 Wiring diagram for Hall sensors see p. 33
Connection B (Cable AWG 24) brown Motor winding 1 red Motor winding 2 orange Motor winding 3
Planetary Gearhead∅22 mm0.5 - 3.4 NmPage 265/266
Motor Data
Recommended Electronics: Page
Notes 24
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
Spindle Drive∅22 mmPage 299/300
for type A:Encoder MR128/256/512 CPT,Page 318
for type B:Resolveron request
Connector: 8-pol 2.5 mm z.B. MKF 13268-6-0-808 Stocko Elektronik GmbH
max
on
EC
mo
tor
186
12 24 36 4836100 41700 41800 44900327 198 132 110
31700 37800 37900 4100017.1 16.8 16.7 16.15.67 3.23 2.14 1.68155 204 210 21949.1 37.4 25.7 21.585 86 86 86
0.244 0.641 1.4 2.230.0182 0.0546 0.123 0.189
3.15 5.46 8.18 10.13030 1750 1170 941235 206 200 2065.2 4.54 4.41 4.562.11 2.11 2.11 2.11
M 1:1
4060000
15000
30000
45000
1.5 3.0 6.0
5 1510
386665
4.5
386665 386666 386667 386668386669 386670 386671 386672
10 K/W 2 K/W 4.85 s 278 s -40…+135°C 155°C
< 4.5 N 0 mm > 4.5 N max. 0.14 mm
4 N 53 N 250 N 16 N
1 3 85 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344ESCON 70/10 344DEC Module 24/2, 50/5 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 22 ∅22 mm, brushless, 40 Wattsterilizable
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 60 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A and B, motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33
Motor Data
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
Planetary Gearheadsterilizable ∅22 mm0.5 - 2.0 NmPage 268
Recommended Electronics: Page
Notes 24
maxon modular system Overview on page 20–25
Application Sterilization information
Sterilizable Devices Tested for 100 sterilization cycles in an autoclave.
No need to dismantle.
Orthopedic Drills & Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
187187
max
on
EC
mo
tor
18 24 4831000 29500 32200383 263 153
28300 27100 3000049 48.2 47.3
9.11 6.4 3.43643 690 856116 89.1 60.289 90 90
0.155 0.269 0.7970.0178 0.035 0.1185.53 7.75 14.21730 1230 67248.4 42.9 37.72.07 1.84 1.614.09 4.09 4.09
M 1:1
10060000
15000
30000
45000
2.0 4.0 8.0 12.0
10 3020
386673
40 50
6.0 10.0
386673 386674 386675386676 386677 386678
386673
7 K/W 1 K/W 4.92 s 355 s -20…+100°C 155°C
< 4.5 N 0 mm > 4.5 N max. 0.14 mm
4 N 40 N 250 N 16 N
1 3 128 g
ESCON 36/3 EC 342ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5, 70/10 344DEC Module 24/2, 50/5 346EPOS2 24/2, Module 36/2 350EPOS2 24/5, 50/5, 70/10 351EPOS2 P 24/5 354EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 22 ∅22 mm, brushless, 100 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 60 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A brown Motor winding 1 Pin 1 red Motor winding 2 Pin 2 orange Motor winding 3 Pin 3 yellow VHall 3…24 VDC Pin 4 green GND Pin 5 blue Hall sensor 1 Pin 6 violet Hall sensor 2 Pin 7 gray Hall sensor 3 Pin 8 Wiring diagram for Hall sensors see p. 33 Connection B (Cable AWG 24) brown Motor winding 1 red Motor winding 2 orange Motor winding 3
Planetary Gearhead∅22 mm0.5 - 3.4 NmPage 265/266
Motor Data
Recommended Electronics: Page
Notes 24
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
Spindle Drive∅22 mmPage 299/300
for type A:Encoder MR128/256/512 CPT,Page 318
for type B:Resolveron request
Connector: 8-pol 2.5 mm z.B. MKF 13268-6-0-808 Stocko Elektronik GmbH
max
on
EC
mo
tor
188
24 4232400 32700
195 11329400 3000041.9 41.86.03 3.48546 61277.4 50.190 91
0.31 0.8390.0438 0.131
7.06 12.21350 78159.4 53.62.55 2.294.09 4.09
M 1:1
10060000
15000
30000
45000
1.0 2.0 4.0
10 20 30
386679
3.0 5.0 6.0
386679 386680386681 386682
7 K/W 1 K/W 5.01 s 355 s -40…+135°C 155°C
< 4.5 N 0 mm > 4.5 N max. 0.14 mm
4 N 45 N 250 N 16 N
1 3 128 g
ESCON 36/3 EC 342 ESCON Mod. 50/4 EC-S 343ESCON Module 50/5 343ESCON 50/5 344ESCON 70/10 344DEC Module 24/2, 50/5 346
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 22 ∅22 mm, brushless, 100 Wattsterilizable
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 60 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection A and B, motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33
Motor Data
A with Hall sensorsB sensorless
A with Hall sensors B sensorless
Planetary Gearheadsterilizable ∅22 mm0.5 - 2.0 NmPage 268
Recommended Electronics: Page
Notes 24
maxon modular system Overview on page 20–25
Application Sterilization information
Sterilizable Devices Tested for 100 sterilization cycles in an autoclave.
No need to dismantle.
Orthopedic Drills & Saws Sterilization with steamSurgical Reamers Temperature +134°C ± 4°CArthroscopic Shavers Compression pressure up to 2.3 barSurgical Staplers Rel. humidity 100 %Dental Tools Cycle length 18 minutes
189189
max
on
EC
mo
tor
M 1:1
426448426449
25 100 150 20048 48 48 48
13300 13600 13800 1410063.9 53.4 54.9 56.5
11400 11700 12200 1320057.9 44 32.4 14.91.72 1.35 1.03 0.515460 346 295 25613.4 10.3 8.98 7.9387 86 85 84
3.59 4.64 5.35 6.050.626 0.626 0.626 0.62634.4 33.5 32.9 32.3278 285 290 29629 39.5 47.2 55.4
2.31 3.16 3.77 4.437.63 7.63 7.63 7.63
189
9.12 K/W 0.92 K/W 5.84 s 462 s -55 … +200°C +240°C
< 5 N 0 mm > 5 N max. 0.14 mm
8 N 98 N 250 N 16 N
1 3 210 g
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible winding temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
EC 22 ∅22 mm, brushless, 80 WattHeavy Duty – for applications in air
Values at nominal voltage and ambient temperature °C1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed1) rpm5 Nominal torque (max. continuous torque)1) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed / torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
1) Values for operation in thermal equilibrium.
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 20 000 rpm24 Axial play at axial load 25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor (sensorless)
Connection A, motor cable PTFE (AWG 19) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors cable PTFE (AWG 24) green VHall 4.5…24 V blue GND red Hall sensor 1 black Hall sensor 2 white Hall sensor 3 Connection B, motor cable PTFE (AWG 19) red Motor winding 1 black Motor winding 2 white Motor winding 3
Motor Data (provisional)
A with Hall sensorsB sensorless
Operating Range Comments
n [rpm] TA = 25°C
TA = 100°C
TA = 150°C
TA = 200°C
Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible win-ding temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
Application NoticeGeneral– extreme temperature applications– vibration tested (according to MIL-STD810F/Jan2000
Fig. 514.5C-10)– ultra-high vacuum applications
(low outgassing, can be baked out at 240°C)Aerospace– gas turbine starter/generators for aircraft engines– regulation of combustion enginesOil & Gas Industry– oil, gas and geothermal wellsRobotics– robotic exploration vehiclesIndustry– pumps and valves for liquid metal cooling systems/turbine fuel
and steam control– valve adjustment for gas and steam power plants
This motor contains leaded solder. It therefore does not fulfill the requirements for the permitted maximum concentration of hazardous substances in accordance with the EC directive 2011/65/EC (RoHS) for all applications. The motor may there-fore only be used for devices that are not subject to this directive.
25000
20000
15000
10000
5000
10 20 30 40 50 60
120 W
80 W
40 W
20 W
M [mNm]
0.5 I [A]1.0 1.5 2.0
max
on
EC
mo
tor
190
M 1:1
426450426451
25 100 150 20048 48 48 48
12900 13400 13600 13800384 177 183 1888410 8510 9130 10600149 120 92.2 55.84.48 3.61 2.88 1.86460 346 295 25613.4 10.3 8.98 7.9371 77 75 73
3.59 4.64 5.35 6.050.626 0.626 0.626 0.62634.4 33.5 32.9 32.3278 285 290 29629 39.5 47.2 55.4
2.31 3.16 3.77 4.437.63 7.63 7.63 7.63
0.793 K/W 0.754 K/W 4.78 s 40.2 s -55 … +200°C +240°C
< 5 N 0 mm > 5 N max. 0.14 mm
8 N 98 N 250 N 16 N
1 3 210 g
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible winding temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
M 1:1
EC 22 ∅22 mm, brushless, 240 WattHeavy Duty – for applications in oil
Values at nominal voltage and ambient temperature °C1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed1) rpm5 Nominal torque (max. continuous torque)1) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed / torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
1) Values in thermal steady state.
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 20 000 rpm24 Axial play at axial load 25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor (sensorless)
Connection A, motor cable PTFE (AWG 19) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection A, sensors cable PTFE (AWG 24) green VHall 4.5…24 V blue GND red Hall sensor 1 black Hall sensor 2 white Hall sensor 3 Connection B, motor cable PTFE (AWG 19) red Motor winding 1 black Motor winding 2 white Motor winding 3
Motor Data (provisional)
A with Hall SensorsB sensorless
Operating Range Comments
n [rpm] TA = 25°C
TA = 100°C
TA = 150°C
TA = 200°C
Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible winding temperature will be reached during continuous ope-ration at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
Application NoticeGeneral– extreme temperature applications– vibration tested according to MIL-STD810F/Jan2000
Fig. 514.5C-10– operation in oil and high pressure (only minimal
lubrication, therefore use under rated ambient condi-tions is not suggested)
Oil & Gas Industry– oil, gas and geothermal wells
This motor contains leaded solder. It therefore does not fulfill the requirements for the permitted maximum concentration of hazardous substances in accordance with the EC direc-tive 2011/65/EC (RoHS) for all applications. The motor may therefore only be used for devices that are not subject to this directive.
Reference medium: Shell Tellus oil T15Operation in oil of different viscosity will affect the motor data.
25000
20000
15000
10000
5000
20 40 60 80 100 120 M [mNm]
1.0 I [A]2.0 3.0 4.0
140
240 W200 W
140 W
80 W
Planetary Gearhead∅22 mm2.0 - 4.0 NmPage 267
maxon modular system Overview on page 20–25
191191
max
on
EC
mo
tor
3664100242
6220035.16.74158029494
0.1220.0145.36178040.62.325.45
M 3:2
250
10000
20000
5 10
10 20 30 40 50
351144
30000
40000
50000
60000
70000
2.5 7.5 12.5
351144
6.54 K/W 0.1 K/W 0.509 s 332 s -20…+100°C +125°C
< 9 N 0 mm > 9 N max. 0.14 mm
0.025 mm 7 N 87 N 5000 N 20 N
1 3 240 g
ESCON Mod. 50/5 343ESCON 50/5 344ESCON 70/10 344 24
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 25 ∅25 mm, brushless, 250 WattHigh Speed
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 70 000 rpm24 Axial play at axial load
25 Radial play 26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection motor (Cable AWG 18) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection sensors (Cable AWG 26) green VHall 3…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3
Motor Data
Recommended Electronics: Page
Notes
max
on
EC
mo
tor
192
12 18 18 24 36 4815100 14300 13100 11000 14700 11300662 404 349 199 211 104
13400 12700 11500 9450 13200 974044.6 45.2 45.9 47.2 43.8 45.96.51 4.15 3.82 2.46 2.07 1.23428 443 407 355 454 35357.2 37.4 31.4 17.3 19.7 8.8480 81 81 80 81 80
0.21 0.481 0.573 1.39 1.83 5.430.03 0.0752 0.09 0.226 0.285 0.8567.48 11.8 13 20.5 23.1 401280 806 737 465 414 23935.8 32.7 32.6 31.5 32.8 32.57.49 6.86 6.82 6.59 6.87 6.820 20 20 20 20 20
M 1:2
118891 118892 118888 118889 118893 118890
5.4 K/W 2.5 K/W 14.8 s 1180 s -20…+100°C +125°C
< 8 N 0 mm > 8 N max. 0.14 mm
5.6 N 98 N 1200 N 28 N
1 3 270 g
ESCON Mod. 50/5 343ESCON Mod. 50/4 EC-S 343ESCON 50/5 344ESCON 70/10 344DEC Module 50/5 346EPOS2 24/5, 50/5, 70/10 351EPOS2 P 24/5 354EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 32 ∅32 mm, brushless, 80 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. permissible speed1) 25 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection motor (Cable AWG 22) red Motor winding 1 black Motor winding 2 white Motor winding 3 Connection sensors (Cable AWG 26)1)
green VHall 4.5…24 VDC blue GND red/grey Hall sensor 1 black/grey Hall sensor 2 white/grey Hall sensor 3 Wiring diagram for Hall sensors see p. 33 1) Not lead through in combination with resolver.
Planetary Gearhead∅32 mm0.75 - 4.5 NmPage 272
Motor Data
Recommended Electronics: Page
Notes 24
Planetary Gearhead∅32 mm0.75 - 6.0 NmPage 274–278
Encoder HED_5540500 CPT, 3 channelsPage 326/328Resolver Res 26∅26 mm10 VPage 337
Spindle Drive∅32 mmPage 301–303
193193
max
on
EC
mo
tor
15 24 42 489840 9840 10100 9840617 386 230 193
9090 9120 9380 9150171 165 161 16512.2 7.39 4.24 3.692620 2660 2740 2760181 115 69.1 59.689 89 89 89
0.0829 0.209 0.608 0.8060.0329 0.0843 0.246 0.337
14.5 23.2 39.6 46.4659 412 241 2063.77 3.71 3.7 3.572.12 2.09 2.08 2.0153.8 53.8 53.8 53.8
M 1:2
369146
100 150 20050
5 15 2010
170
369146 393023 393024 393025
5.21 K/W 1.05 K/W 18.7 s 1910 s -40…+100°C +155°C
< 9 N 0 mm > 9 N max. 0.14 mm
23 N 106 N
5500 N 75 N
1 3 580 g
ESCON Mod. 50/5 343ESCON Mod. 50/4 EC-S 343ESCON 50/5 344ESCON 70/10 344DEC Module 50/5 346EPOS2 24/5, 50/5, 70/10 351EPOS2 P 24/5 354EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 40 ∅40 mm, brushless, 170 Watt
Motor Data (provisional)
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data 17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 18 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static)
(static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor
Values listed in the table are nominal.
Connection motor (Cable AWG 16) red Motor winding 1 Pin 1 black Motor winding 2 Pin 2 white Motor winding 3 Pin 3 N.C. Pin 4 Connector Part number Molex 39-01-2040 Connection sensors (Cable AWG 26) yellow Hall sensor 1 Pin 1 brown Hall sensor 2 Pin 2 grey Hall sensor 3 Pin 3 blue GND Pin 4 green VHall 3…24 VDC Pin 5 N.C. Pin 6 Connector Part number Molex 430-25-0600 Wiring diagram for Hall sensors see p. 33
Planetary Gearhead∅42 mm3 - 15 NmPage 283Planetary Gearhead∅52 mm4 - 30 NmPage 287
Recommended Electronics: Page
Notes 24
Encoder HED_5540500 CPT, 3 channelsPage 326/328Resolver Res 26∅26 mm10 VPage 337Brake AB 3224 VDC0.4 NmPage 374
max
on
EC
mo
tor
194
12 12 18 18 24 24 36 36 48 489780 5650 10300 5930 10500 6090 9360 5400 10200 58601530 577 1120 419 879 328 471 177 411 1548410 4370 9000 4680 9290 4840 8150 4190 8960 4640174 186 171 184 169 183 179 191 174 18716.2 9.65 11.2 6.72 8.55 5.13 5.29 3.14 4.21 2.521380 872 1540 931 1600 952 1560 911 1650 962119 43.6 93.3 32.6 74.8 25.6 43.1 14.5 37.2 12.579 79 80 79 80 79 81 80 81 80
0.101 0.275 0.193 0.552 0.321 0.936 0.836 2.48 1.29 3.850.0266 0.0797 0.0542 0.163 0.0917 0.275 0.263 0.788 0.395 1.19
11.5 20 16.5 28.6 21.4 37.1 36.3 62.8 44.5 77.1827 478 579 334 445 257 263 152 214 1247.22 6.58 6.78 6.46 6.67 6.49 6.07 6 6.22 6.188.99 8.19 8.44 8.05 8.32 8.08 7.56 7.48 7.75 7.7119 119 119 119 119 119 119 119 119 119
M 1:4
136202 136196 136203 136197 136204 136198 136205 136200 136206 136201
136204
1.9 K/W 0.9 K/W 15.4 s 1600 s -20…+100°C +125°C
1
< 20 N 0 mm > 20 N max. 0.14 mm
16 N 182 N 5000 N 140 N
1 3 850 g IP54*
ESCON Mod. 50/5 343ESCON Mod. 50/4 EC-S 343ESCON 50/5 344ESCON 70/10 344DEC Module 50/5 346EPOS2 50/5, 70/10 351EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 45 ∅45 mm, brushless, 150 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 15 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor Protection to
Values listed in the table are nominal.
Connection motor (Cable AWG 16) Cable 1 Motor winding 1 Cable 2 Motor winding 2 Cable 3 Motor winding 3 Connection sensors (Cable AWG 24)1)
white Hall sensor 3 brown Hall sensor 2 green Hall sensor 1 yellow GND grey VHall 4.5 … 24 VDC Wiring diagram for Hall sensors see p. 33 1) Not lead through in combination with resolver.
Option Temperature monitoring, PTC resistance Micropille
110°C, R 25°C < 0.5 kW, R 105°C = 1.2…1.5 kW, R 115°C = 7…13 kW, R 120°C = 18…35 kW
Planetary Gearhead∅42 mm3 - 15 NmPage 283
Motor Data
Recommended Electronics: Page
Notes 24
Planetary Gearhead∅52 mm4 - 30 NmPage 288
Encoder HEDL 9140500 CPT, 3 channelsPage 331Resolver Res 26∅26 mm10 VPage 337Brake AB 2824 VDC0.4 NmPage 373
* Protection level only when installed with flange-side seal.
195195
max
on
EC
mo
tor
24 24 36 36 48 488670 5000 10400 6010 10700 6160897 341 834 312 656 2447970 4300 9730 5320 10000 5490311 331 312 341 316 34712.5 7.51 10.2 6.21 7.94 4.864400 2540 5750 3320 6110 3530167 55.8 175 58.3 143 47.786 85 87 86 87 87
0.143 0.43 0.206 0.617 0.336 1.010.0565 0.17 0.0883 0.265 0.149 0.448
26.3 45.5 32.8 56.9 42.7 73.9364 210 291 168 224 1291.98 1.98 1.82 1.82 1.76 1.764.34 4.34 3.99 3.99 3.85 3.85209 209 209 209 209 209
M 1:4
136210 136207 136211 136208 136212 136209
136210
1.7 K/W 1.1 K/W 31 s 1570 s -20…+100°C +125°C
< 20 N 0 mm > 20 N max. 0.15 mm
16 N 182 N
5000 N 180 N
1 3 1150 g IP54*
ESCON Mod. 50/5 343ESCON Mod. 50/4 EC-S 343ESCON 50/5 344ESCON 70/10 344DEC Module 50/5 346EPOS2 50/5, 70/10 351EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
May 2014 edition / subject to change maxon EC motor
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 45 ∅45 mm, brushless, 250 Watt
Motor DataValues at nominal voltage
1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 12 000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static)
(static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor Protection to
Values listed in the table are nominal.
Connection motor (Cable AWG 16) Cable 1 Motor winding 1 Cable 2 Motor winding 2 Cable 3 Motor winding 3 Connection sensors (Cable AWG 24)1)
white Hall sensor 3 brown Hall sensor 2 green Hall sensor 1 yellow GND grey VHall 4.5…24 VDC Wiring diagram for Hall sensors see p. 33 1) Not lead through in combination with resolver.
Option Temperature monitoring, PTC resistance Micropille
110°C, R 25°C < 0.5 kW, R 105°C = 1.2…1.5 kW, R 115°C = 7…13 kW, R 120°C = 18…35 kW
Planetary Gearhead∅42 mm3 - 15 NmPage 283Planetary Gearhead∅52 mm4 - 30 NmPage 288
Recommended Electronics: Page
Notes 24
Encoder HEDL 9140500 CPT, 3 channelsPage 331Resolver Res 26∅26 mm10 VPage 337Brake AB 2824 VDC0.4 NmPage 373
Planetary Gearhead∅62 mm8 - 50 NmPage 289
* Protection level only when installed with flange-side seal.
max
on
EC
mo
tor
196
48 485370 3100733 304
4960 2680747 8309.38 5.85
11800 6820139 46.486 85
0.345 1.030.273 0.8284.9 147113 65
0.457 0.4573.98 3.98831 831
M 1:4
167132 167131
167131
1.3 K/W 0.5 K/W 33.9 s 1200 s -20…+100°C +125°C
< 30 N 0 mm > 30 N max. 0.14 mm
24 N 392 N 6000 N 240 N
1 3 2450 g IP54*
ESCON Mod. 50/5 343ESCON Mod. 50/4 EC-S 343ESCON 50/5 344ESCON 70/10 344DEC Module 50/5 346EPOS2 70/10 351EPOS3 70/10 EtherCAT 357MAXPOS 50/5 360
maxon EC motor May 2014 edition / subject to change
Stock programStandard programSpecial program (on request)
Part Numbers
Specifications Operating Range Comments
n [rpm] Continuous operationIn observation of above listed thermal resistance (lines 17 and 18) the maximum permissible wind-ing temperature will be reached during continuous operation at 25°C ambient.= Thermal limit.
Short term operationThe motor may be briefly overloaded (recurring).
Assigned power rating
maxon Modular System Overview on page 20–25
EC 60 ∅60 mm, brushless, 400 Watt
Values at nominal voltage1 Nominal voltage V2 No load speed rpm3 No load current mA4 Nominal speed rpm5 Nominal torque (max. continuous torque) mNm6 Nominal current (max. continuous current) A7 Stall torque mNm8 Stall current A9 Max. efficiency %
Characteristics10 Terminal resistance phase to phase W11 Terminal inductance phase to phase mH12 Torque constant mNm/A13 Speed constant rpm/V14 Speed/torque gradient rpm/mNm15 Mechanical time constant ms16 Rotor inertia gcm2
Thermal data17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing 19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature
Mechanical data (preloaded ball bearings)23 Max. speed 7000 rpm24 Axial play at axial load
25 Radial play preloaded26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported) 28 Max. radial load, 5 mm from flange
Other specifications29 Number of pole pairs 30 Number of phases 31 Weight of motor Protection to Values listed in the table are nominal. Connection motor (Cable AWG 16) Cable 1 Motor winding 1 Cable 2 Motor winding 2 Cable 3 Motor winding 3 Connection sensors (Cable AWG 24)1)
white Hall sensor 3 brown Hall sensor 2 green Hall sensor 1 yellow GND grey VHall 4.5 … 24 VDC blue Temperature sensor (PTC) pink Temperature sensor (PTC) 1) Not lead through in combination with resolver. Temperature monitoring, PTC resistance Micropille
110°C, R 25°C < 0.5 kW, R 105°C = 1.2…1.5 kW, R 115°C = 7…13 kW, R 120°C = 18…35 kW Wiring diagram for Hall sensors see p. 33
Planetary Gearhead∅81 mm20 - 120 NmPage 290
Motor Data
Recommended Electronics: Page
Notes 24
Encoder HEDL 9140500 CPT, 3 channelsPage 331Resolver Res∅26 mm10 VPage 337Brake AB 4124 VDC2.0 NmPage 375
* Protection level only when installed with flange-side seal.