Maximize PV Rooftop Space and Energy Output
with Horizontal String Inverter Accessory
![Page 2: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/2.jpg)
q This webinar will be available afterwards at www.solarpowerworldonline.com & email
q Q&A at the end of the presentation q Hashtag for this webinar: #SolarWebinar
Before We Start
![Page 3: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/3.jpg)
Steven Bushong Solar Power World
Moderator Presenters
Efrem Tagliamonte Advanced Energy Industries
Tucker Ruberti Advanced Energy Industries
![Page 4: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/4.jpg)
Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory
![Page 5: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/5.jpg)
About AE
PV Industry Leader with Proven Reliability • Invented transformerless 3-Phase string inverters • 230,000+ units and 3+ GW installed since 2007 • Estimated 99.8% global fleet availability
30-year Focus on Power Conversion Solutions • Founded in 1981 in Ft. Collins Colorado • 5 major sites: Fort Collins, Colorado; Bend, Oregon; Toronto, Ontario; Metzingen,
Germany, and Shenzhen, China • Dedicated solar applications and service organization
Profitable, Diversified and Public (AEIS:NASDAQ) • Solar Product Line: PV inverters and energy management solutions • Precision Power Product Line: Power conversion solutions for thin-film and industrial
applications • Consistently profitable and no debt
![Page 6: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/6.jpg)
String Inverters – NEC 2011/2014 Combiner
Fused Recombiner
Inverter
1000VDC Integral Combiner AFCI Compliant Rapid Shutdown Floating Design
Inverters:
3TL evolving to meet all code requirements, at lower costs
![Page 7: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/7.jpg)
NEC 2014 Key Issue 690.12: Rapid Shutdown of PV Systems on Buildings
• PV system circuits on builds must comply with new rapid shutdown rules only if they are more than 10 feet from a PV array, or extend more than 5 feet into a building
• The rapid shutdown requires that the array conductors be limited to 30 volts and 240 watts within 10 seconds
• This effectively requires either string inverters, or contactor combiners with remote disable functions because the rapid shutdown is not practical or economical
![Page 8: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/8.jpg)
3TL “Rapid Shutdown” Challenges
• Using the inverter as the combiner and disconnect creates challenges: • Direct sun exposure • Snow and moisture • Inverter shade contribution to the array
![Page 9: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/9.jpg)
Easy to Install - Horizontal
1 – Mount the inverter to the horizontal bracket 2 – Attach the sunshade and display window cover 3 – Attach the fan bracket to the inverter 4 – Wire the fan to the analog sensor terminal 5 – Attach side panels
Enables reliable compliance with “Rapid Shutdown”
![Page 10: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/10.jpg)
Challenge – Sun and Snow Exposure
![Page 11: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/11.jpg)
Challenge – Shading from Inverter
![Page 12: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/12.jpg)
Deep Dive – Side by Side Comparison
![Page 13: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/13.jpg)
Improved Thermal Performance vs Vertical
![Page 14: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/14.jpg)
String Inverter Horizontal Mounting Benefits • Eliminate combiner boxes and fused recombiners of central
inverters • Enable cost effective compliance with NEC 2011 and NEC 2014 • Provides a OEM-engineered solution for mounting string inverters
on roofs • Improves thermal performance and protects from rain and snow • Minimizes shade and maximizes roof space for power generation
![Page 15: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/15.jpg)
String Inverters – Energy Delivered
=
Energy earnings impacted by inverter performance
DC Power
X X X
Inverter Efficiency
MPPT Efficiency
Inverter Availability
![Page 16: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/16.jpg)
DC Power
More energy harvest or fewer inverters - more flexibility to choose
= DC Power x Inverter Efficiency x MPPT Efficiency x Inverter Availability
Widest range in the industry q Max DC Ratio – 1.75 q Wide MPP – 200V wakeup
![Page 17: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/17.jpg)
DC Power – Rooftop Case 1 – Fixed AC
Same AC
$1.9M Earned in 20yrs
DC ratio allows $ Generation on ↑ WDC
![Page 18: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/18.jpg)
DC Power – Rooftop Case 1 – Fixed DC
Same DC
$100k Savings Now
DC ratio allows $ Material Savings on ↓ WAC
![Page 19: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/19.jpg)
Inverter Efficiency
Widest range in the industry q CEC Efficiency – 98.0% q Real-world Efficiency
Beats PVSYST models using 3-level curve by 1-2%
= DC Power x Inverter Efficiency x MPPT Efficiency x Inverter Availability
Wide performance band, Forgiving design flexibility
![Page 20: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/20.jpg)
Inverter Efficiency – Modeling
PVSYST doesn’t have enough resolution
PVSYST Efficiency Curves
![Page 21: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/21.jpg)
Inverter Efficiency – In Practice Real-world Performance
q String voltage and inverter efficiency aligned in optimal region
q A shift for project design flexibility still yields acceptable performance
Design Flexibility
![Page 22: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/22.jpg)
MPPT Efficiency
MPP Tracking Leader q Published to EN 50530 q Real-world 99.7 - 99.9% precision
= DC Power x Inverter Efficiency x MPPT Efficiency x Inverter Availability
More time harvesting, less time waiting
![Page 23: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/23.jpg)
Inverter Availability Proven In the Industry
q High MTBF Proven reliability over 3+GW Fleet
q Fast MTTR Simplified spares stocking – just inverters Simplified service requirements – inverter swap RMA warranty process – ship back defect for a new unit
= DC Power x Inverter Efficiency x MPPT Efficiency x Inverter Availability
Simplified Planning in Operations
![Page 24: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/24.jpg)
Availability Review Uptime Detail: q Operation per year = 8760 Hrs x .5 (for daytime only) = 4380 Hrs/Yr q Down time for planned maintenance per inverter = 0 Hrs/Yr q Downtime for unplanned maintenance per inverter = 1.8 Hrs/Yr
Example for 100 Inverters:
Estimated Uptime= Operational Time/Total Time =(1− 100 x 1.8/100 x 4,380 ) x 100%=𝟗𝟗.𝟗𝟔% q Safe contingency for guaranteed performance is 99.5% without a maintenance contract. q 20 Year O&M cost $216k for the total project in parts + labor
Increased uptime, Decreased O&M Costs
![Page 25: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/25.jpg)
To find out more…
Home Page: http://solarenergy.advanced-energy.com/ Solar Products: http://solarenergy.advanced-energy.com/solar-inverters String Calcs: http://aedesign.advanced-energy.com/Default.aspx?ReturnUrl=%2f Reference Library: http://solarenergy.advanced-energy.com/en/reference_library.html
![Page 26: Maximize PV Rooftop Space & Energy Output with Horizontal String Inverter Accessory](https://reader037.fdocuments.net/reader037/viewer/2022103002/55a4074b1a28ab22538b458b/html5/thumbnails/26.jpg)
Questions? Steven Bushong Solar Power World [email protected] Twitter: @Solar2Steven
Efrem Tagliamonte Advanced Energy Industries [email protected]
Tucker Ruberti Advanced Energy Industries [email protected]