Math modelled approach to gas-exchange monitoring
-
Upload
cosmin-balan -
Category
Health & Medicine
-
view
292 -
download
1
Transcript of Math modelled approach to gas-exchange monitoring
![Page 1: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/1.jpg)
MATH-MODEL DRIVEN APPROACH TO GAS-EXCHANGE MONITORING
![Page 2: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/2.jpg)
Classic Approach to Gas-Exchange Monitoring
Normalized ratio /
difference
Equation / model
based monitoring
![Page 3: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/3.jpg)
Dead Space Ventilation
-two compartment modeling-
FACO2/ET CO2
V T
VDana
water
FEO2
FECO2
FIO2
FICO2
VA1
FAO21
FACO21
VCO2 VO2
Q1
Q
Q2=0
Q
VA2
FAO22
FACO22
VA2/f =VDalv
๐ญ๐ฐCO2 = 0
FACO22 = 0
FECO2 = ๐๐๐๐๐ด๐ฝ
PECO2
BTPS= FECO2 ร (๐๐๐ โ ๐๐)
VCO2 = FACO2 ร ๐๐ = ๐ ๐๐๐๐ ร ๐๐ ร ๐
FACO2 ร ๐๐ = FACO21 ร VA
1 = VCO2
๐ ๐๐๐๐ร ๐๐ = FACO21 ร VT โ (VDana
+VDalv)
VDana +V๐alv = Vdphys = VTร๐ ๐๐๐๐
๐โ๐ ๐๐๐๐
๐ ๐๐๐๐๐
VDana + V๐alv = Vdphys = VT ร ๐๐๐๐๐โ๐๐๐๐๐
๐๐๐๐
๐๐๐๐๐
![Page 4: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/4.jpg)
Bohr equation
VDanat/VT = ๐ท๐จ๐ช๐ถ๐โ๐ท๐ฌ๐ช๐ถ๐
๐ท๐จ๐ช๐ถ๐
Enghoff modification
VDphysiol/VT = ๐ท๐๐ช๐ถ๐โ๐ท๐ฌ๐ช๐ถ๐
๐ท๐๐ช๐ถ๐
Alveolar dead space by substraction VDalv/VT = Enghoff โ Bohr
VDalv/VT alv = ๐ท๐๐ช๐ถ๐โ๐ท๐๐๐ช๐ถ๐
๐ท๐๐ช๐ถ๐
Dead Space -fractions-
PACO2-alv mixed-EtCO2(mean)
EtCO2=mean!-(min+max)/2
![Page 5: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/5.jpg)
Dead Space Caveats
Shunt dependence ( โshunt dead spaceโ โ Suter,1975)
because assuming that PaCO2=PACO2 is flawed
Shunt dependence will spuriously elevate VD
Regions with โ Va/Q are poorly set apart from regions with
Va/Q = โ(true dead space) because CO2 solubility is rather
modest in comparison to acetone solubility, which is used in
MIGET and distingushes VD as regions with Va/Q>100)
Severe V/Q mismatch => โsloping alveolar plateauโ
Severe heterogeneity in ฯ => โsloping alveolar plateauโ
Sometimes PetCO2 > PaCO2
![Page 6: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/6.jpg)
Shunt dependence of VD
Bull Eur Physiopathol Respir 1984
Effect of right-to-left shunting on alveolar dead space.
Mecikalski et al
![Page 7: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/7.jpg)
Negative โ CO2
Great heterogeneity in RโขC product or/and severe V/Q mismatch
-sloping alveolar plateau-
![Page 8: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/8.jpg)
Negative โ CO2
ETCO2 is continuously estimated while PaCO2 is a mean value.
ETCO2 can be regarded as a regional and temporal specific parameter while PaCO2 is a global, mean
parameter with no regional or temporal attributes
A low ฯ CO2(FRC/VCO2) as in IACS or a non-homogeneous ฯ lung(RโขC) will facilitate negative
differences
![Page 9: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/9.jpg)
Slow alveoli are characterized by a high RC and this assigns them a constant,
moderate sloping.
Fast alveoli are characterized by a low RC and this gives them a 2 phase sloping, the
second being responsible for the overshoot ( high FRC/VCO2 )
Eg. Obese patients ( Ecw high )
Negative โ CO2
![Page 10: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/10.jpg)
Dead Space as risk factor -Enghoffโs dead space-
PULMONARY DEAD-SPACE FRACTION AS A
RISK FACTOR FOR DEATH IN THE ACUTE
RESPIRATORY DISTRESS SYNDROME, NEJM
2002, Nuckton et al
![Page 11: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/11.jpg)
Dead Space as a PEEP setter
Optimum end-expiratory airway pressure in
patients with acute pulmonary failure, Suter et
al, NEJM 1975
![Page 12: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/12.jpg)
Dead Space as a PEEP setter
OL-PEEP
OL-PEEP
Monitoring dead space during recruitment and PEEP titration in an
experimental model, ICM 2006, Suarez-Sipmann et al. Recruitment=โ โEELV=โSTRAINst+dyn=โVD
![Page 13: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/13.jpg)
Dead Space as a PEEP setter - VD as an image of respiratory mechanics more than of gas excahnge -
Best PEEP=lowest dynamic and static STRAIN
Best E=Best Vd
VD obeys Hickling model (1998 )
VD shows histeresis
VD is mechanics as well as E and is decoupled from gas
excange ( PaO2 )
Compliance and Dead Space Fraction Indicate an Optimal Level
of Positive End-Expiratory Pressure After Recruitment in
Anesthetized Patients, Anesth Analg 2008, Maisch and Tusman
![Page 14: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/14.jpg)
Volumetric Capnography
ฮฒ
Integrating the CO2 and volume signals
The abscissa is represented by volume
3 phases, 2 slopes, one inflection point-the curve changes sign-
on SII
![Page 15: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/15.jpg)
Volumetric Capnography -phases and derived variables-
Phase I begins with the start of expiration and is completed after
โCO2>0.1% from baseline
Phase II starts at the end of phase I and ends at the intersection point of
slopes SII and SIII. Its inflection point (changes sign) is pretty much its
midpoint and likely represents the interface between Vdaw and alveolar gas,
that is the interface between convection and diffusion. It contains both
alveolar gas as well as Vdaw gas. RC influences phase II.
Phase III begins at the aforementioned intersection and ends with expiration.
This is gas inside the alveoli.
Slope II is an image of acini expiratory times. The more homogeneous the
expiration, the more the slope increases.
Slope III is again influenced by mechanical time constants but mostly by V/Q
mismatch. The slope increases with heterogeneity.
![Page 16: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/16.jpg)
VD
FOWLERโ
DRAGER
FLETCHERโ
NICO
TANG
Volumetric Capnography -the math behind the monitors-
![Page 17: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/17.jpg)
Volumetric Capnography FOWLER 1948 - VDana
![Page 18: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/18.jpg)
Ay=ABCD=PNCD
AMP=MNB=Ax
Ay=VTCO2
PNCD=PDร(PN+CD)/2=VTPDรmeanCO2alv
VTCO2=mean expCO2รVT=mean expCO2(VTPD + VTOP)
( VT โ VTOP) ร mean CO2alv= mean expCO2รVT
VTOP/VT= (meanCO2alv-mean expCO2 )/meanCO2alv
D
o
A P
M
N B
O
C
Ax
Ax
Ay
![Page 19: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/19.jpg)
Volumetric Capnography FLETCHER 1981 โ all VDs
![Page 20: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/20.jpg)
Az/Axyz = PaCO2 ร VDanat/PaCO2 ร VT = VDanat/VT
Ax = VTCO2 = EtCO2mean ร Vtalv
Ay = Vtalv ร ( PaCO2 - meanEtCO2 )
Vtalv ร meanEtCO2 = Vtalveficient ร PaCO2
Ay = Vtalv ร PaCO2 โ Vtalveficient ร PaCO2
Ay = PaCO2 ร Vdalv => Ay/Axyz = VDalv/VT
(Ay+Az)/Axyz = VDphys/VT
![Page 21: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/21.jpg)
Volumetric Capnography TANG 2006 โ all VDs
![Page 22: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/22.jpg)
Vdana and Vdalv can be read simultaneously on the abscissa
Volumetric Capnography TANG 2006 โ all VDs
![Page 23: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/23.jpg)
=225 ml
=160 ml
=65 ml
Volumetric Capnography TANG 2006 โ all VDs
Vdana and Vdalv can be read simultaneously on the abscissa
![Page 24: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/24.jpg)
We draw perpendiculars so that AOJA = AHJI (Fowler)
and AOKB = AFEDK (Tang)
VT = OC ; VDanat = OA (Fowler) ; VDphys = OB (Tang)
PECO2 = AODC /VT
VDphys Enghoff = VT ร (1-PECO2/PaCO2) =
= VT ร (1-AODC/ (PaCO2รVT))
G F E
D
H
I
K
J
C
J
A B C
D
E F G
H
I
K
AODC = AOKB + ABKDC = ABKDC+AFEDK = ABCEF
VDphys Enghoff = VTร[1-ABCEF/(PaCO2รVT) ]=
= VTร[1-(PaCO2รBC)/(PaCO2รVT)]
= OB = VDphys Tang
![Page 25: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/25.jpg)
Volumetric Capnography assessing recruitment/recruitability
Volumetric capnography for monitoring lung function during mechanical
ventilation, Yearbook of Intensive Care Medicine 2006, Suarez โ Sipmann et
al
![Page 26: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/26.jpg)
Volumetric Capnography assessing recruitment/recruitability
Volumetric capnography for monitoring lung function during mechanical
ventilation, Yearbook of Intensive Care Medicine 2006, Suarez โ Sipmann et
al
![Page 27: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/27.jpg)
Volumetric Capnography assessing recruitment/recruitability
Lung Recruitment Improves the Efficiency of Ventilation and Gas
Exchange During One-Lung Ventilation Anesthesia, Anesth and Analg,
Tusman, Suarez Sipmann et al., 2004
![Page 28: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/28.jpg)
How Tusman et al have confused Graf
Bohr equation
VDphysiol/VT = ๐ท๐จ๐ช๐ถ๐โ๐ท๐ฌ๐ช๐ถ๐
๐ท๐จ๐ช๐ถ๐
PACO2-alv mixed-
EtCO2(mean)
![Page 29: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/29.jpg)
The answer lies in slopes
![Page 30: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/30.jpg)
Diffusion Limitation - one compartment modeling -
V T
VDana water
FEO2
FECO2
FIO2
FICO2
CvO2
Q
CcO2
PcO2
CaO2
Q
VCO2 VO2
VA
PAO2
PACO2
๐๐๐๐๐๐๐ ๐๐๐๐๐๐๐๐๐๐ ๐ท๐จ๐ช๐ถ๐ = ๐ฌ๐ป๐ช๐ถ๐๐๐๐๐
PAO2=PIO2 - PACO2 ร ๐ญ๐ฐ๐ถ๐ +๐โ๐ญ๐ฐ๐ถ๐
๐น
RDIFF = ๐
๐ซ๐ณ๐ถ๐
RDIFF = ๐ท๐จ๐ถ๐โ๐ท๐๐ถ๐
๐ฝ๐ถ๐
RDIFF, when computed through a one compartment model, is nothing but a global parameter,
It does not set apart any of the gas-exchange abnormalities.
![Page 31: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/31.jpg)
Shunt Model - two compartments, one parameter -
FACO2/ET CO2
V T
VDana
water
FEO2
FECO2
FIO2
FICO2
VA1
FAO21
FACO21
VCO2 VO2
Q1
Q
Q0 or
Qshunt
Q=Q1+ Q0
VA0= 0
CvO2
CaO2 CvO2
CcO21 PcO2
1
CaO2= 1/Q ร ๐ธ๐๐ช๐๐ถ๐๐๐
๐=๐
๐ช๐๐ถ๐ = ๐/๐ธ ๐ธ๐๐๐๐๐ร ๐ช๐๐ถ๐+ ๐ธโ๐ธ๐๐๐๐๐ ๐ช๐๐ถ๐๐
๐๐๐๐๐ = ๐ช๐๐ถ๐
๐โ๐ช๐๐ถ๐๐ช๐๐ถ๐
๐โ๐ช๐๐ถ๐
PAO2=FIO2ร ๐ท๐ฉโ๐ท๐จ๐ช๐ถ๐
๐น๐ธ (simplified alv.eq.)
๐ท๐จ๐ช๐ถ๐ ๐๐๐๐ ๐๐, ๐๐ ๐๐๐๐๐๐๐ ๐๐ ๐๐๐ ๐๐๐ ๐๐, ๐ฌ๐ป๐ช๐ถ๐๐๐๐๐ .
๐บ๐จ๐ถ๐ ๐๐๐๐ ๐๐ ๐๐๐๐๐๐๐ ๐๐๐๐ ๐ท๐จ๐ถ๐ ๐๐๐๐๐๐ ๐๐๐ ๐๐ ๐ ๐๐๐๐๐๐๐๐๐๐ ๐ถ๐ซ๐ช ๐๐๐๐๐๐๐๐
SO2= ๐ท๐ถ๐๐+ ๐๐๐๐ท๐ถ๐
โ ๐ ร ๐๐, ๐๐๐ + ๐ -1
๐ต๐๐๐, ๐ช๐๐ถ๐ ๐๐๐๐ ๐๐ ๐๐๐๐๐๐๐๐ ๐๐๐๐: CcO2=(Hbร ๐บ๐ถ๐ ร ๐. ๐๐) + (๐ท๐ถ๐ ร ๐. ๐๐๐๐)
![Page 32: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/32.jpg)
True Shunt - FIO2 = 1 trial -
CcO2-CaO2/
CcO2-Cv02
True shunt(S1)
at FiO2=1, there is S2>S1 through
resorbtion atelectasis.
V/Q mismatch
![Page 33: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/33.jpg)
V/Q Mismatch Model - two compartments, one parameter -
FAO2 VA
FACO2/ET CO2
V T
VO2
VDana
water
FEO2
FECO2
FIO2
FICO2
VA-VA2
PAO21
PACO21
VCO2
1 VO2
1
Q1
Q
Q2
Q=Q1+ Q2
CaO2=CcO2 CvO2
CcO21 PcO2
1
FAO21
FAO22
VA2
PAO22
PACO22
VCO2
2 VO2
2
PcO22 CcO2
2
PcO2n=PAO2
n โPO2=PAO2-PcO2=PAO2-PaO2
๐ช๐๐ถ๐๐ = ๐ท๐๐ถ๐
๐๐ถ๐ถ๐+๐ฏ๐ ๐ถ๐ซ๐ช ๐ท๐๐ถ๐๐
CcO2
2 = PcO22ฮฑO2 + Hb ODC(PcO2
2)
๐ฝ๐ถ๐๐ = ๐ โ ๐๐จ๐ ร ๐ฝ๐จ ร ๐ญ๐ฐ๐ถ๐โ ๐ญ๐จ๐ถ๐
๐
VO21 = Qร ๐. ๐ ร (๐ช๐๐ถ๐
๐โ ๐ช๐๐ถ๐)
๐ฝ๐ถ๐๐ = ๐๐จ๐ ร ๐ฝ๐จ ร ๐ญ๐ฐ๐ถ๐โ ๐ญ๐จ๐ถ๐
๐
VO22 = Qร ๐. ๐ ร (๐ช๐๐ถ๐
๐โ ๐ช๐๐ถ๐)
๐๐จ๐ =๐ฝ๐จ๐๐ฝ๐จ
= ๐ญ๐จ๐ถ๐โ ๐ญ๐จ๐ถ๐
๐
๐ญ๐จ๐ถ๐๐โ ๐ญ๐จ๐ถ๐
๐
![Page 34: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/34.jpg)
Monoparametric
gas exchange monitoring
V/Q mismatch
Alveolar deadspace Rdiff
Shunt
![Page 35: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/35.jpg)
Fitting one parameter models to data
84
86
88
90
92
94
96
98
100 SaO2
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
FEO2
Shunt=21%
fA2=0.27
Shunt=11%
fA2=0.19
Shunt=10%
fA2=0.14
Shunt=8%
fA2=0.14
Dashed red line Alveolar dead space model
Vdalv/VT=53%
Diffusion limitation model
Rdiff=42kPa/(l/min)
V/Q model
fA2=0.27
Solid orange line Shunt model
Shunt=15.5%
stands for SaO2/FEO2 for the same
patient.
using all necessary data, it is
calculated for each of these four
points shunt and fA2 according to
previous equations.
fitting parameter model to data =
finding the one parameter value that will
subsequently describe patientโs data
with utmost precision
one parameter models show dependence on inspired O2 fraction
they cannot appropriately describe gas-exchange
![Page 36: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/36.jpg)
Beginnings of Two Parameter Models
The PIO2 vs. SpO2 diagram: A non-invasive measure of pulmonary oxygen
exchange, EUROPEAN JOURNAL OF ANAESTHESIOLOGY 1995, Sapsford and
Jones - Cambridge
The two parameters are shunt and V/Q mismatch +
PACO2/R effect measured as % and as P I O2-PcO2
(kPa) respectively
Mass balance for O2 in blood and air, ODC equation,
computer algorithm based on fitting the model
parameters to P I O2/SaO2 data pairs
![Page 37: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/37.jpg)
Beginnings of Two Parameter Models
A noninvasive method for evaluating the effect of thoracotomy on shunt and
perfusion inequality, ANAESTHESIA 1997, Gray and Jones
![Page 38: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/38.jpg)
Beginnings of Two Parameter Models - course of family of curves -
Noninvasive assessment of shunt and ventilation/perfusion ratio in neonates with
pulmonary failure, Arch Dis Child Fetal Neonatology Ed. 2001, J G Jones et al
![Page 39: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/39.jpg)
We need the numbers
In A there is dependency of PIO2 vs SaO2 on aVDO2.
Given that aVDO2 is dependent on Q, we infer Q dependency.
Simply eyeballing might not be enough. We need the numbers.
In B there is dependency on Hb. Hb is nonetheless more
stable.
The PIO2 vs. SpO2 diagram: A non-invasive measure of pulmonary oxygen
exchange, EUROPEAN JOURNAL OF ANAESTHESIOLOGY 1995, Sapsford and
Jones - Cambridge
![Page 40: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/40.jpg)
Reverse avDO2 dependency - monitoring cardiac output -
Cardiac output estimation using pulmonary mechanics in mechanically
ventilated patients, Biomedical Engineering Online 2010, Sundaresan et al
![Page 41: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/41.jpg)
Refinement of the two parameter models
โขRdiff(โPO2) Shunt
โขAlveolarDS(โPO2) Shunt
โขV/Q mismatch(โPO2) Shunt
Mathematical models of pulmonary gas exchange - validation and application to
postoperative hypoxaemia , Aalborg Hospital, Denmark, Soren Kjaergaard
![Page 42: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/42.jpg)
V/Q mismatch and Shunt Model - three compartments, 2 parameters -
FAO2 VA
FACO2/ET CO2
V T
VO2
VDana
water
FEO2
FECO2
FIO2
FICO2
VA-VA2
PAO21
PACO21
VCO2
1 VO2
1
Q1
Q=Qc+ Qshunt
Q2
Qc=Q1+ Q2
CaO2
CvO2 Q
CcO21 PcO2
1
FAO21
FAO22
VA2
PAO22
PACO22
VCO2
2 VO2
2
PcO22 CcO2
2
PcO
2n=
PAO
2n
โPO
2=
PAO
2-P
cO2
Qshunt
CcO2 PcO2
๐ฝ๐ถ๐ = ๐ โ ๐๐จ๐ ร ๐ฝ๐จ ร ๐ญ๐ฐ๐ถ๐โ ๐ญ๐จ๐ถ๐๐ + ๐๐จ๐ ร ๐ฝ๐จ ร ๐ญ๐ฐ๐ถ๐ โ ๐ญ๐จ๐ถ๐
fA2 = VA2/VA
FAO2 = (1-fA2)ร ๐ญ๐จ๐ถ๐
๐+ ๐๐จ๐ ร ๐ญ๐จ๐ถ๐๐
๐ฝ๐ถ๐ = ๐ฝ๐ถ๐๐+ ๐ฝ๐ถ๐
๐ = ๐ธ ร (๐ช๐๐ถ๐ โ ๐ช๐๐ถ๐)
VO2 = Q1 ร ๐ช๐๐ถ๐๐โ ๐ช๐๐ถ๐ + ๐ธ๐ ร (๐ช๐๐ถ๐
๐โ ๐ช๐๐ถ๐)
๐ช๐๐ถ๐ = Q1/ ๐ธ๐ ร ๐ช๐๐ถ๐๐+ Q2/ ๐ธ๐ ร ๐ช๐๐ถ๐
2
CaO2 = (1-shunt) ร ๐ช๐๐ถ๐ + shunt ร ๐ช๐๐ถ๐
๐ช๐๐ถ๐๐ = ๐ท๐๐ถ๐
๐๐ถ๐ถ๐+๐ฏ๐ ๐ถ๐ซ๐ช ๐ท๐๐ถ๐๐
CcO2
2 = PcO22ฮฑO2 + Hb ODC(PcO2
2)
![Page 43: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/43.jpg)
Fitting two parameter models to data
All three models are equivalent in assessing
shunt
All three models are equivalent in assessing
โPO2
VDalv inferred from an O2 based 2 parameter
model is NOT equivalent to the one determined
from a CO2 based model
Rdiff is not supported by MIGET as an
important constituent of gasexchange
disturbances
VDalv O2 based has no meaning in day to day
clinical practice
![Page 44: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/44.jpg)
V/Q mismatch and Shunt Model - shunt and fA2 impact on ODC -
SHUNT V/Q or fA2
![Page 45: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/45.jpg)
Predicting risk of hypoxemia
V/Q mismatch vs Shunt
![Page 46: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/46.jpg)
Predicting risk of hypoxemia
DISCRIMINATING BETWEEN THE EFFECT OF SHUNT AND REDUCED VA/Q ON ARTERIAL OXYGEN
SATURATION IS PARTICULARLY USEFUL IN CLINICAL PRACTICE, J Clin Monit and Comp 2000, Jones et al
![Page 47: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/47.jpg)
MIGET at the bedside
![Page 48: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/48.jpg)
![Page 49: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/49.jpg)
![Page 50: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/50.jpg)
PaO2/FIO2
Risk indicator as in Berlin ARDS definition
Global gas - exchange parameter
Non independent behavior with respect to shunt,
avDO2, PaCO2, RQ, Hb
Non independent parameter when FIO2 is varied
![Page 51: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/51.jpg)
PaO2/FIO2 FIO2 dependency according to shunt
avD02 is constant, that is constant metabolism
Three shunt values
At each shunt value, PaO2/FIO2 shows FIO2 dependence
![Page 52: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/52.jpg)
PaO2/FIO2 FIO2 dependency according to avDO2
avD02 varies, that is changing CO for a constant VO2
Same shunt value
At each avDo2 value, PaO2/FIO2 shows FIO2 dependence
![Page 53: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/53.jpg)
PaO2/FIO2 FIO2 dependency according to shunt
Shunt varies from 0% to 30%
Thick lines stand for clinically important SaO2 (92%-98%)
At each shunt value, PaO2/FIO2 shows FIO2 dependence
![Page 54: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/54.jpg)
PaO2/FIO2 FIO2 dependency according to V/Q
โPO2 ( image of V/Q ) varies from 0 kPa to 30 kPa
Thick lines stand for clinically important SaO2 (92%-98%)
At each โPO2 value, PaO2/FIO2 shows FIO2 dependence
![Page 55: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/55.jpg)
PaO2/FIO2 FIO2 dependency โ switching risk groups
Six pacients, graphs with SaO2/FIO2 and PaO2/FIO2 FIO2 dependency, two models are used โ shunt and shunt+V/Q,
thick lines pertain to SaO2 = 92%-98%, dashed line is shunt model whereas solid line is the other PaO2/FIO2 FIO2
dependency brings about different risk groups even though shunt or V/Q do not really change.
![Page 56: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/56.jpg)
FiO2โ FiO2โ
normal Mild hO2 ALI ARDS
Shunt model Nr =23
Nr=15
Nr=40
Nr=38
Normal =64 23 14 27 0
Mild hO2 =20 0 1 13 6
ALI=14 0 0 0 14
ARDS=18 0 0 0 18
Shunt+V/Q mism Nr=42 Nr=19 Nr=31 Nr=24
Normal=56 39 12 5 0
Mild hO2 =19 3 6 9 1
ALI=23 0 1 16 6
ARDS=18 0 0 1 17
PaO2/FIO2 FIO2 dependency โ switching risk groups
N > 350 ; mild hypoxemia = 300 โ350 ; ALI = 201-300 ; ARDS < 200
![Page 57: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/57.jpg)
PaO2/FIO2 FIO2 dependency โ switching risk groups
risk group โswitchingโโ is 50% for shunt model and 38% for two
parameter model
by โ FiO2 (SpO2=92-98%)
- shunt model ALI 14โ40
- shunt model ARDS 18โ38
- two parameter model ALI 23โ31
- two parameter model ARDS 18โ24
The shunt model has a poor fit to the data
PaO2/FiO2 is FIO2 dependent (use the same FIO2 when tracking
evolution)
PaO2/FiO2 is a poor gas exchange tracker
![Page 58: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/58.jpg)
โPerhaps more appropriate would be to replace the PaO2/FiO2 ratio
with two parameters, a parameter to describe the oxygenation
problems due to V/Q mismatch and one to describe oxygenation
problems due to shunt.โ
Kjaergaard and Rees, Critical Care 2007
![Page 59: Math modelled approach to gas-exchange monitoring](https://reader034.fdocuments.net/reader034/viewer/2022051502/58ee36391a28abec578b45e7/html5/thumbnails/59.jpg)