MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140...

6
COMPATIBILITY (ISO 2943:1999) Full with fluids: HH-HL-HM-HV-HTG (according to ISO 6743/4) For fluids different than the above mentioned, please contact our Sales Department. WORKING TEMPERATURE From -25° to +110° C MATERIALS Head: Aluminium alloy Bowl: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass PRESSURE (ISO 10771-1:2002) Max working: 2 MPa (20 bar) Test: 4 MPa (40 bar) Bursting: 6 MPa (60 bar) Collapse, differential for the filter element (ISO 2941): 300 kPa (3 bar) BYPASS VALVE Setting: 170 kPa (1,7 bar) ± 10% PH APPLICATION EXAMPLE COMPONENTS PRESSURE FILTERS

Transcript of MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140...

Page 1: MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140 6.190 990 3.390 4.360 6.520 c b a kg 0,20 0,60 1,00 1,35 % ),/7(5 +286,1*) ),/7(5

COMPATIBILITY (ISO 2943:1999)

Full with fl uids: HH-HL-HM-HV-HTG(according to ISO 6743/4)For fl uids different than the above mentioned, please contact our Sales Department.

WORKING TEMPERATURE

From -25° to +110° C

MATERIALS

Head:Aluminium alloy

Bowl:Steel

Bypass valve:Polyammide

Seals:NBR Nitrile

Indicator housing:Brass

PRESSURE (ISO 10771-1:2002)

Max working:2 MPa (20 bar)

Test:4 MPa (40 bar)

Bursting:6 MPa (60 bar)

Collapse, differential for the fi lter element (ISO 2941): 300 kPa (3 bar)

BYPASS VALVE

Setting: 170 kPa (1,7 bar) ± 10%

PH

APPLICATION EXAMPLE

COMPONENTS

P R E S S U R E F I L T E R S

Page 2: MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140 6.190 990 3.390 4.360 6.520 c b a kg 0,20 0,60 1,00 1,35 % ),/7(5 +286,1*) ),/7(5

FILTER HOUSING

kg

FPH31

FPH40

FPH50

FPH52

3/8” - 1/2”M18 x 1,5

3/4” - 1”

1” 1/4

1” 1/2

81

114

156

156

8,5

10,5

13

13

114

150

240

240

50

50

90

90

-

-

20

20

42

50

80

80

70

85

135

135

15

12

56

56

10

13

13

13

114

204

180

250

44

58

62

62

27

35

45

45

20

20

25

25

1,3

3,2

6,1

6,8

D1 D3 E E1 E2 E3 E4 E5 E6 H1 H2 H4 RD2

19

30

38

38

H3

INSTALLATION DRAWINGPH P R E S S U R E F I LT E R S

E1

E5E6

D3

H4

E4

E3E2

E

D1

H4

H3

H1

R

D2

D1

Page 3: MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140 6.190 990 3.390 4.360 6.520 c b a kg 0,20 0,60 1,00 1,35 % ),/7(5 +286,1*) ),/7(5

FILTER ELEMENTArea (cm2)

Media F+ Media C+A B C

ERA31

ERA40

ERA50

ERA52

70

99

130

130

28

40

63

63

93

178

148

208

620

3.010

4.140

6.190

990

3.390

4.360

6.520

C

BB

A

kg

0,20

0,60

1,00

1,35

N.B. Indicatorseries 70 only on request

ORDERING AND OPTION CHART PHP R E S S U R E F I LT E R S

Page 4: MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140 6.190 990 3.390 4.360 6.520 c b a kg 0,20 0,60 1,00 1,35 % ),/7(5 +286,1*) ),/7(5

Δp (kPa)

15

FPH 31

0 30 60 75 90

10

20

30

40

l/min

1/2"

45

3/8"

Δp (bar)

0,1

0,2

0,3

0,4Δp (kPa)

100

FPH 40-50-52

0 200 400 500 600

10

20

30

40

l/min300

3/4"

Δp (bar)

0,1

0,2

0,3

0,4

N.B. All the curves have been obtained with mineral oil having a kinematic viscosity 30 cSt and specifi c gravity 0,9 kg/dm3; for fl uids with different features, please consider the factors described in the fi rst part of this catalogue. All the curves are obtained from test done at the UFI HYDRAULIC DIVISION Laboratory, according to the specifi cation ISO 3968:2005. In case of discrepancy, please check the contamination level, viscosity and features of the fl uid in use.

PH

FILTER HOUSING PRESSURE DROP(mainly depending on the port size)

The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 50 kPa (0,5 bar).

PRESSURE DROP CURVES (Δp)

FLUID SPEED(when selecting the fi lter size, we suggest to consider also the max recommended fl uid speed (in pressure lines normally 5 < v < 10 m/s).

800

750

700

650

600

550

500

450

400

350

300

250

200

150

100

50

0

FLO

W R

ATE

[l

/min

]

1/2”3/8” 3/4” 1” 1” 1/4 1” 1/2

PORT SIZE

Recommended range

P R E S S U R E F I LT E R S

5 <

v <

10 m

/s

1” 1/4 1” 1/2 1"

Page 5: MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140 6.190 990 3.390 4.360 6.520 c b a kg 0,20 0,60 1,00 1,35 % ),/7(5 +286,1*) ),/7(5

15

ERA 31

0 30 60 75 90

25

50

75

100Δp (kPa)

l/min

FA FB FCFD

CC

45

CD

Δp (bar)

0,25

0,5

0,75

1

50

ERA 40

0 100 200 250 300

25

50

75

100Δp (kPa)

l/min

FA FB FC

FDCC

150

CD

Δp (bar)

0,25

0,5

0,75

1

50

ERA 50

0 100 200 250 300

25

50

75

100Δp (kPa)

l/min

FAFB

FC

FDCC

150

CD

Δp (bar)

0,25

0,5

0,75

1

100

ERA 52

0 200 400 500 600

25

50

75

100Δp (kPa)

l/min

FA FB FC

FD

CC

300

CD

Δp (bar)

0,25

0,5

0,75

1

25

FPH 31

0 50 75 100 125 150

100

200

300

400

l/min

Δp (kPa)Δp (bar)

1

2

3

4

100

FPH 40-50-52

0 200 300 400 500 600

100

200

300

400

l/min

Δp (kPa)Δp (bar)

1

2

3

4

N.B. All the curves have been obtained with mineral oil having a kinematic viscosity 30 cSt and specifi c gravity 0,9 kg/dm3; for fl uids with different features, please consider the factors described in the fi rst part of this catalogue. All the curves are obtained from test done at the UFI HYDRAULIC DIVISION Laboratory, according to the specifi cation ISO 3968:2005. In case of discrepancy, please check the contamination level, viscosity and features of the fl uid in use.

PHThe “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and

of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 50 kPa (0,5 bar).

PRESSURE DROP CURVES (Δp)

CLEAN FILTER ELEMENT PRESSURE DROP WITH F+ AND C+ MEDIA

(depending both on the internal diameter of the element and on the fi lter media)

BYPASS VALVE PRESSURE DROPWhen selecting the fi lter size, these curves must be taken into account if it is foreseen that any fl ow peak is to be absorbed by the bypass valve,

it also must be of proper confi guration to avoid pressure peaks. The valve pressure drop is directly proportional to fl uid specifi c gravity.

P R E S S U R E F I LT E R S

Page 6: MATERIALS · 2018. 4. 4. · era50 era52 70 99 130 130 28 40 63 63 93 178 148 208 620 3.010 4.140 6.190 990 3.390 4.360 6.520 c b a kg 0,20 0,60 1,00 1,35 % ),/7(5 +286,1*) ),/7(5

A NE RHPB XB X

CLOGGING INDICATORA visual or visual-electrical diffe-rential indicator is available as an option and allows monitoring of the element conditions, giving an exact indication of the right time to replace the element.

FLEXIBILITY OF MOUNTINGA second outlet, usually plugged, provides an optional mounting con-figuration allowing a common PH series unit to be used on variety of applications.

STRONG CONSTRUCTIONThe materials and the design ensu-re a superior resistance to fatigue even at working pressures up to 2000 kPa (20 bar).

NO LEAKSThe end caps with captive O-rings ensure a perfect seal between filter element and housing.

“LONG LIFE” FILTER ELEMENTThe filter elements are designed with a very large filter area giving a highest dirt holding capacity.

For further technical informations and other options see page 182-183.

P R E S S U R E F I LT E R SPH

5B

T0

6B - 7B

SERIES 31

CLOGGING INDICATOR

SPARE PARTS ELEMENTS (For filling up see table “Ordering and option chart”)

FILTER ELEMENT CLOGGING INDICATORFILTER HOUSING

521.0075.2

521.0076.2

521.0077.2

521.0077.2

NBR FKM

FPH31

FPH40

FPH50

FPH52

521.0006.2

521.0007.2

521.0008.2

521.0008.2

FPH31

FPH40

FPH50

FPH52

008.0149.1

008.0048.1

008.0094.1

008.0094.1

Is this datasheet the latest release? Please check on our website.

SERIES P1

SPARE SEAL KIT

SPARE SPRING

Tech

nica

l dat

a su

bjec

t to

varia

tions

with

out p

rior n

otic

e. P

H -

EN

- 03

a/20

11

Differential