Match UPS Product Management July 2004. Contents. Range Topology Unique Selling Points Key Features Accessories Applications. - PowerPoint PPT Presentation

Transcript of Match UPS Product Management July 2004

Page 1: Match UPS Product Management July 2004

Match UPSProduct ManagementJuly 2004

Page 2: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

RangeTopologyUnique Selling PointsKey FeaturesAccessoriesApplications

Contents

Page 3: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

“Even a moment’s disruption can have devastating effects on power sensitive customers such as internet service providers, data centres, wireless telecommunications networks, on line traders, computer chip manufacturers and medical research centres. For these customers, power disruptions can result in data corruption, burned circuit boards, component damage, file corruption and lost customers.” - “Electrical Power Interruption Cost Estimates for Individual Industries, Sectors and US Economy” February 2002, US Dept of Energy, Office of Power Technologies

“The system and its data can become corrupt as a result of power failure…a UPS can protect the system if power is lost. A UPS usually provides…temporary power which may be enough to permit a graceful shutdown” - Special Publication 800-34 Contingency Planning Guide for Information Technology Systems, National Institute of Standards and

Technology, June 2002

Page 4: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Models available include

500, 700, 1000, 1500, 2200 & 3000VA tower models 700, 1000, 1500, 2200 & 3000VA 19inch rackmount models Longer runtime (L) version for 700VA and 1000VA 2200 and 3000VA with DC connector for additional batteries

Matching battery cabinets

Range

Page 5: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Control Inverter

Boost

Buck

Normal

Battery

SafetyRelay

AVRRelay

IN

OUT

Line Interactive

Topology

Page 6: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

A Line Interactive UPS provides:

Battery back up and voltage stabilisationAs well as providing back up power from the battery when the mains fails, the UPS filters the mains during normal operation, regulating the incoming voltage

Cost effective UPS protection Lower price compared to on line UPS

Topology

Page 7: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

A Line Interactive UPS provides:

Small break in powerDuring the switch from mains to battery, there is a small loss of power to the load (typically 2-4ms, not affecting most computer type loads)

Medium degree of protection When compared to on line (double conversion) UPS

Topology

Page 8: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Excellent High Voltage ProtectionThe Match UPS will protect itself and the

supported load up to 350VAC. Most UPS will damage themselves or the load if the input voltage exceeds 300V

Low ‘Green’ Power Consumption Compared to other line interactive UPS, the

power consumption is extremely low during normal operation

Unique Selling Points

Page 9: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Unique Selling Points

Optimised Sinewave Output The output waveform is sinusoidal with a linear load, and with a crest load is slightly flattened. This avoids high current peaks on the electronics and the battery, and still provides high efficiency.

This is the optimal solution between sinewave and stepwave UPS outputs. Stepwave UPS can cause some electronic equipment to malfunction.

Page 10: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Additional USPs, Match 2200 & 3000 Extremely wide input voltage window

At 165-275V (500-1500VA) and 140-305V (2200 & 3000VA), the output voltage is limited to 190-254V. This minimises the need for battery use, extending battery life

Battery charging even at 140VAC Even in poor mains conditions there is a fast recovery of battery power, increasing up time and battery life

High battery recharge current

When additional battery packs are connected, the charger current automatically increases to 10A, ensuring much faster recharge time

Page 11: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Additional USPs, Match 2200 & 3000

Deep battery calibration testThe actual battery capacity can be tested and calibrated. This ensures the predicted runtime stays accurate throughout the life of the UPS

Load dependent end of dischargeIf the discharge time is shorter, batteries may be discharged deeper. This features ensures maximum runtime is is given at any load level, without the risk of damaging the battery during longer power failures

Page 12: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Automatic voltage regulationThe buck and boost function minimises battery operation, increasing the battery life. With an inout voltage window of 165-275V, the output voltage is limited to 190-254V

Crest factor input acceptance 6:1The Match is especially suited for computer loads, and no oversizing is necessary

Key Features

Page 13: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Battery start (cold start)Allows the UPS to be switched on without mains power, for mobile applications or to perform a quick action during a mains failure

Extended communicationRS232, SNMP and contact interface communication (plug in options for Match 700L and above)

Key Features

Page 14: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Key Features – Superior Battery ManagementAutomatic monthly

battery testing

Charger off at end of discharge period

Automatic boost charge

2 hours battery recharge time

The UPS keeps running in normal operation over the test, rather than switching to battery. If the battery is damaged or empty, the load is still supported

Lowest battery temperature during mains operation

Prevents battery depletion beyond recharge capability

Safe battery test

Alerts the user that the batteries need to be replaced

For areas with poor mains, ensures a faster recharge time than with float charge only

On battery at less than 5% load, the UPS performs an automatic shutdown to protect the battery. This function can be disabled

Means that loads even in very poor mains areas can be supported more than once during a shift

The electronic design of the UPS means the battery temperature is very low, increasing battery life

No load shutdown

Page 15: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Accessories SNMP Card Can be used with Match 700L upwards

Presents UPS information across a network via: SNMP Agent (one or more NMS can monitor, manage and control the UPS) Web Server (UPS data in HTML format, so standard internet browser can be used to monitor UPS) Easy installation through RS232 slot SNMP box also available

Network Protection Software CD packed with UPS free of charge, with intelligent communication cable. Simple installation Virtually invisible operation under normal conditions Provides a graceful shutdown of load after a lengthy mains failure Supports all major operating systems DataShield supplied for JAVA supported operating systems

Page 16: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

Accessories Relay Interface Card Can be used with Match 700L upwards Easily installed into CardConnect slot at rear of UPS Provides 4 potential free contacts for:

Mains failure

General alarm

Battery low

Bypass active

and a 9 pole Sub-D connector

Manual Service Bypass Contains a manual bypass switch Allows for maintenance or testing of UPS with no interference to the protected load Pluggable as standard, but can be hardwired using the internal terminal strip

Page 17: Match UPS Product Management July 2004

Match UPSProduct Management

July 29th, 2004

PCs

Servers

Workstations

Hubs, switches and routers

Cash register systems (EPOS)

Fax, modem, ISDN adaptors

Applications

Page 18: Match UPS Product Management July 2004