Mariner 5+3 Offshore Diesel Welder
Rental Centers Across North America
Red-D-Arc Welderentals is North America's leading provider of rental welding products andservices, with over 50,000 units in a fleet that includes welders, welding positioners and otherwelding-related equipment, for almost any type of welding process and application.
1-866-733-3272
500 AMP DC CC WELDER/GENERATOR
OFFSHORE PROTECTION PACKAGE
KUBOTA F2803 DIESEL ENGINE POWER
3kW 120 VAC AUXILIARY POWER
North America’s Largest Fleet of Welding and Positioning Equipment
Mariner 5+3 Offshore Diesel Welder
D503K 5+3HO
Overhead and Vertical
Normal Welding
Large Electrodes
Do Not TurnWhile Welding
350
300
250 200 150 100 90 70
400
350
300 250 200 15 0 125 90
Max
500
450
4
00
350 300 250 200 150 140 105
RED-D-ARCRED-D-ARCWelderentals
www.red-d-arc.com
Current Control Job Selector Electrode PolarityOff
(Switch is inoperative when CV Adaptor is installed.Change polarity by reversing leads at output studs.)
Nor
mal
Welding
Med
ium OCV
Rea
d Cu
rrent
on Blue Dial Low OCV
Read Current on Red Dial
OverHead and Vertical S
pecial Applications
Extra Low
OC
V High
OC
V
Rea
d Cur
rent
on
Silv
er D
ial
115VAC each 26 Amp Maximum Total
Adjust to Either Side of Center Mark in Desired Job
Range for Fine Current Adjustment
Increase
Made in Canada
Large
r Ele
ctro
des
Rated Output:400 Amps 36 Volts100% Duty Cycle97 Max O.C.V.1800 RPM No Load3000 Watt AC Auxiliary
Model RA - 400 - V3300
Code No.
Serial No.
Danger Use No Ether
1. Be sure the engine Stop control is pushed in.2.Turn the Start / Preheat switch to the Preheat position (Turn Counter Clockwise). Above 5oC (41oF) preheat for 5 seconds. Below 5oC (41oF) preheat for 15 seconds. (This will heat the glow plugs and the engine combustion chambers.)3. To crank and start the engine turn Start / Preheat switch (clockwise) to the start position. Release the switch when engine starts.4. If the engine does not start within 15 seconds, release the switch and repeat steps 2 and 3
Starting Instructions
1-800-245-3660
Neutral Bonded to FrameNeutre Raccorde au Bati
Specifications
DC AMPERAGE RANGE
MAXIMUM OCV
RATED CC OUTPUT
AUXILIARY POWER
WEIGHT
FUEL CAPACITY
FUEL CONSUMPTION
FUEL TYPE
FUEL FILTER
ENGINE OIL CAPACITY
ENGINE OIL TYPE
OIL FILTER
COOLANT CAPACITY
AIR FILTER ELEMENT
OPERATING SPEED
DIMENSIONS
Control Panel
50 - 575 A Stick
97 V
400 A at 36 VDC, 60% duty cycle
350 A at 34 VDC, 100% duty cycle
3,000 Watts
120 VAC, 26 A
Single-phase, 60 Hz
GFCI duplex receptacle
2480 lb (1125 kg)
32 gal (121 L)
1.79 gal (6.78 LPH) at rated load
No. 2-D (ASTM D975) only
Kubota 16631-43650
12.7 qt (12 L)
above CD grade
Kubota 15521-32430
8.67 qt (8.2 L)
Kubota TA040-93230
1800 RPM
H: 58" (1473 mm)
W: 31" (787 mm)
L: 87" (2210 mm)
Processes
Description
Stick Welding and Air Carbon Arc Gouging
Features
EngineKubota F2803-BG, liquid-cooled, five cylinder, 38.4 HP @ 1800 rpm, 167.56 cu.in. Engine modifications include automatic over-run protection which automatically shuts off the engine in the event of excessivespeed, an exhaust mounted spark arrrestor, and a lifetime pre-fuel cannister filter.
1. Job Selector (Reactor Controlled) 3. Polarity Switch2. 120 VAC, 15 A Duplex Receptacle 4. Current Control Rheostat
Battery ammeter, engine temperature gauge and engine hour meter arelocated on the front panel below the control panel
Fuel efficient, low noise level, F2803 Kubota diesel engine with special offshore modificationsEngine runs at a constant 1800 RPM for longer service intervals, long engine life and low operating costsEngine preheat provides excellent cold weather starting (with no ether required)Automatic low oil pressure engine shutdown protectionHigh output, copper wound generator provides excellent welding characteristicsFull-protective enclosure is finished in a salt-water resistant three-coat paintBattery ammeter, engine coolant temperature gauge, engine hour meter are standard Single 120 VAC, 15 A duplex receptacle (optional GFCI receptacle available)Standard remote control receptacleAvailable with optional CV wire feed module for constant-voltage welding processes
The Mariner 5+3 is a 400 amp @ 60% duty cycle, constant current, DC diesel engine-driven welder with 3,000 watts 120 VACauxiliary power. Its copper wound “pure DC” generator provides excellent welding characteristics and has enough power forgouging with up to 3/16" carbons. Output adjustment is via dual continuous output controls and the polarity of the outputterminals is selected via a two-position polarity switch. Fine current control can be adjusted remotely by connecting a rheostat-type remote control to the standard remote control receptacle. A specially-built protective enclosure minimizes saltwater intrusion and incorporates a built-in drip pan/reservoir to contain fluids in the event of an engine-oil or -coolant leak, aswell as easy-opening access panels for convenient equipment operation and maintenance. Welding generator enhancementsinclude modifications such as stainless steel brush holders for enhanced corrosion resistance in harsh environments.