Many States and Local Utilities Offer Additional Rebates
description
Transcript of Many States and Local Utilities Offer Additional Rebates
PEERLESS® PINNACLE®
Rev2
PEERLESS® PINNACLE®
Rev2
Many States and Local Utilities Offer Additional RebatesVisit www.dsireusa.org/incentives to Find Rebates in Your Area.
PEERLESS® PINNACLE®
Rev2
PEERLESS® PINNACLE®
Rev2
Giannoni Stainless Steel Heat ExchangerMono Block
Bottom-Up Burner Connection Helps Keep Flue Gasses from
Backing out at Shut-Down
Top Vent Outlet for Simplified Vent
Connection
At the Heart of AllPureFire Heat Exchangers - the Stainless Steel Loop –
Highly Resistant to Corrosion
PEERLESS® PINNACLE®
Rev2
Giannoni Stainless Steel Heat ExchangerMono Block
Separate Condensate Drain Connections for Heat Exchanger
& Vent Connectors
Boiler Return
(In)
Boiler Supply (Out)
Supply Sensor
Return Sensor
Drain/Purge Valve(Supplied)
Baffle in Manifold to Separate
Supply & Return Water
PEERLESS® PINNACLE®
Rev2
Removable Front Plastic Cover - Removable Metal Side PanelsWell-Sealed Cabinet - Prevents Combustion Odors which
Promotes Healthy Indoor AirTop Connections – Fuel, Piping Wiring & Venting
Sleek & Functional Mono Design
Main Control
Left Side Panel
Front Cover
Vent & Air Connections
Fuel Gas Connection
System Return (In)
System Supply (Out)
Service SwitchDisplay
Condensate System
Blower & Gas Valve
PEERLESS® PINNACLE®
Rev2
Duo Block DesignStainless Steel Heat Exchanger
Bottom-Up Burner Mounting Helps Keep Flue Gasses from
Backing out at Shut-Down
Duo Design Allows Smaller Boiler Footprint
Top Vent Outlet Connection
PEERLESS® PINNACLE®
Rev2
Mono Block Design:4 Inputs: 50, 80, 110 & 140
2 Cabinet Sizes
PureFire 50 & 80 PureFire 110 & 140
PEERLESS® PINNACLE®
Rev2
Duo Design ConceptCondensate Deflector
in Upper Chamber Eliminates the Need
For 2nd Connection on Condensate Collector,
which is Sealed with a Cap
Cooled Exhaust Gas OutletCooled Exhaust Gas Outlet
Condensate Drain
Condensate Deflector
Target Wall
Condensate Drain
Manifold with Return Inlet
&Supply Outlet
After Second Exchange
After First Exchange
Burner
Hot Flue Gas from BurnerCooled Flue Gas After Second Exchange
Cooled Flue Gas After First Exchange
Manifold Between Exchangers
Before Second Exchange
Co
nd
ensa
teD
rip
Return Water
Supply Water
PEERLESS® PINNACLE®
Rev2
Removable Metal Side Panels & Improved Cabinet Seals
Top Connections for Fuel, Venting & Wiring – 8 Knockouts
Lower Left Side Brass Piping Connections
New Duo PureFire Design Features
PEERLESS® PINNACLE®
Rev2
Duo Heat Exchanger Tappings
Boiler Supply (Out)
Boiler Return
(In)
Return Sensor
Supply Sensor
Relief Valve
Drain/Purge Valve(Inside)
Flue Gas Sensor(Other Side)
Vent Pressure Switch(Front Side)
⅝” CondensateConnection
Baffle in Manifold to Separate Supply & Return Water
PEERLESS® PINNACLE®
Rev2
Duo Block Design - Inputs: 210 & 399mbh 2 Cabinet Sizes
PEERLESS® PINNACLE®
Rev2
PureFire 210 & 399 Ratings
Boiler Model
Input (MBH)Heating Capacity (MBH)
Net I=B=R Ratings (MBH)
AFUE (%)Appx Shipping Weight (lbs)
Minimum Maximum
PF-210 42 210 192 167 97.3 160
Boiler ModelInput (MBH) Gross
Output (MBH)
Net I=B=R Ratings (MBH)
Thermal Efficiency (%)
Combustion Efficiency (%)
Appx Shipping Weight (lbs)
Minimum Maximum
PF-399 80 399 373 324 93.4 95.5 250
• 5:1 Turndown Ratio• Can Be Higher When Approval Agencies Raise Maximum• Higher Turndown with Large Inputs Are More Reliable & Have a Greater Impact on Efficiency• Vent Length As Much As 200’ Total Equivalent • Circulators
PF-210 – Taco 0014 or Grundfos UPS 26-99FCPF-399 – Taco1400-20 or Grundfos UP 32-80F
PEERLESS® PINNACLE®
Rev2
Full-Featured & Easy-To-Use Boiler Control
with Plain English Text Display No Need to Memorize Codes
Most Features are Pre-Programmed & Ready-to-go
PEERLESS® PINNACLE®
Rev2
New Features Scheduled for Release withPF-210 & PF-399 in 2009
Display Main Control
Same Location for Display As Mono Block Design
New Location for Main Control for Easy Access
PEERLESS® PINNACLE®
Rev2
All PureFire Boiler Controls Use Fuse Protection- Easily Replaceable Fuse -
Main Control
Fuse Size = 5mm x 20mm, 250 Volt, Slow Blow
Available at Radio Shack (Part# 270-1067) 4-Pack - $2.99
PEERLESS® PINNACLE®
Rev2
Molded Plastic JacketWith Tinted Clear Lens for Viewing Control Display
PEERLESS® PINNACLE®
Rev2
EBM-Papst Blowers Dungs Gas Valves
Extensively Field-Tested by Peerless
Patented Whirlwind Technology Promotes Better
Fuel/AirMixing for Better Combustion
Various Swirl Plates for Different Boiler Sizes
PEERLESS® PINNACLE®
Rev2
Dungs Gas Valve Operation
Adjust CO2 ONLY with Throttle Screw
Gas valves are preset at factory for fuel type
Fuel Pressure can be measured at Inlet Pressure Tap
PEERLESS® PINNACLE®
Rev2
Worgas Metal Mesh BurnersProvide Stable and Reliable Flame
Igniters & Flame SensorsProvide Dual Sensing of Burner Flame – Help Prevent Unnecessary Lockouts
PEERLESS® PINNACLE®
Rev2
Molded Plastic Vessels for Condensate Collection & Neutralizing
Optional for PF-210 & 399
PEERLESS® PINNACLE®
Rev2
Simplified Electrical ConnectionsPre-Wired Harnesses & Split Terminal Strips
PEERLESS® PINNACLE®
Rev2
Additional Features
Leveling Legs Courtesy Outlet
PEERLESS® PINNACLE®
Rev2
Features
Outdoor SensorFor Outdoor Reset
(Supplied as Standard Equipment)
Knock-out GrommetFor Low-Voltage WiresHelps Protect Wires &Keep Cabinet Sealed
PEERLESS® PINNACLE®
Rev2
Venting Options: PVC, CPVC & PP (M&G)with Stainless Steel, Concentric PVC & PP Termination Options
PEERLESS® PINNACLE®
Rev2
Control DisplaySample Screens
PEERLESS® PINNACLE®
Rev2
Control DisplaySample Screens
PEERLESS® PINNACLE®
Rev2
Control Features
Feature Description
Cascade Multiple boilers operate together in order to satisfy the heating or DHW demand.
One Hour RetryOne hour after a lockout on ignition or flame failure, the PUREFIRE control will reinitiate boiler operation.
Restore System Defaults
Allows the installer to reset all parameters to the factory defaults if desired. The installer can also save and restore site defaults.
Adjustable Blower Postpurge
This feature allows the installer to increase the blower postpurge to counteract the effects of high winds or unusual wind currents.
Flame Signal LogThis troubleshooting tool captures the flame signal at four increments during the two second flame proving period. This can help installers/service personnel to quickly diagnose problems with flame rectifications.
Fault HistoryThe PUREFIRE control allows service personnel to access the last 15 Blocking Errors and the last 15 Lockout Errors in addition to records of the interval between Errors.
New or Enhanced in 2009
PEERLESS® PINNACLE®
Rev2
New Control Features Cascade Firing of Multiple Boilers
• Control up to16 Boilers in One System
• No Extra Controls Required, Only 1 System Sensor
• Automatic Rotation of Boilers (Lead/Lag)
• No Extensive Programming Required
- Most Options Are Pre-Selected, But Adjustable
• Boilers will be Fired Proportionally with Timed Start and
Stop for Maximum Efficiency & Longevity
• All PureFire™ Boilers will be Cascade Capable
- After the Release of the new PF-210 & PF-399
- Existing PF Boilers Can Be Easily Upgraded
• New Controls will be Compatible with Older Displays &
Vice Versa
PEERLESS® PINNACLE®
Rev2
Cascade Functions with Multiple Boilers
• The Control on Any Boiler can be the Master Control
• Simple Instructions Explain How to Designate the Master
Control and All Dependent Controls
• All Sensors and Non-Boiler Pumps are Wired to the Master
• Control & Status of All Boilers Including Resets can be
Done Through Master
• Each Dependent Boiler Controls Only Its Own Pump
• Boiler Controls are Interconnected in Parallel with only 1 Set of
Thermostat Wires Between Each Boiler
• Future PC Connections can be made to Any Dependent Control
PEERLESS® PINNACLE®
Rev2
Control FeaturesSafety & Efficiency
Feature Description
Freeze ProtectionActivates pumps if temperatures fall below the specified value. If the temperatures continue to fall, the boiler is activated.
Ramp Delay Step Modulation
This feature is used to prevent short cycling in systems using very small zones. The input rate is gradually increased from 20% to 100% over 2 minutes. When used, this only effects central heating operation.
Add’l Safety Functions
Allows the installer to choose between a low water cutoff and a flow switch for water level safety shutdown.
Vent Temperature Safety Limit
Reduces the firing rate if the vent temperature approaches the maximum limit of the vent material. If the vent temperature continues to climb, the PUREFIRE control will shut down the boiler.
Service Notification
If enabled, the PUREFIRE control will display a service notification after an installer defined number of hours or cycles. It can also display a notification based on a date of the installers choosing.
System TestThe PUREFIRE boiler will allow the installer to operate the boiler at low power, high power and ignition input for troubleshooting purposes.
PEERLESS® PINNACLE®
Rev2
Control FeaturesCentral Heating
Feature Description
Outdoor ResetThe PUREFIRE control changes the boiler supply target temperature to compensate for changes in load due to milder outdoor temperatures. This increases the efficiency of the boiler and is more comfortable.
System Type Presets
By choosing the heat distribution type (finned tube baseboard, hydro air, cast iron radiators, cast iron baseboard, low mass radiant or high mass radiant) the installer can automatically select practical boiler design and mild weather temperatures.
Temperature Boost
The temperature boost function increases the boiler supply target to recover more quickly from setback conditions.
Warm Weather Shutdown
The PUREFIRE control will shut down the boilers CH functions if the outdoor temperature is above an installer defined maximum. This prevents the boiler from running during warm weather.
Anti-CyclingThe anti-cycling function prevents rapid on/off cycling of the boiler. This includes an override function to be sure that all loads are satisfied.
PEERLESS® PINNACLE®
Rev2
Outdoor Reset
PEERLESS® PINNACLE®
Rev2
Central Heating Mode ChoicesCH Mode Display Text Description
0 Indoor ThermostatCall-for-Heat signal from thermostat with user selected boiler supply target setpoint temperature. (Factory Default)
1Thermostat and Outdoor Reset
Call-for-Heat signal from thermostat with boiler supply target temperature calculated using outdoor temperature.
2 Full Outdoor ResetContinuous heat demand with boiler supply target temperature calculated using outdoor temperature.
3 Permanent Demand Continuous heat demand with user selected boiler supply target temperature.
40-10 V Input to modulate Setpoint
This mode is not available at this time.
5 0-10 V Input to modulate Rate
This mode is not available at this time.
6 Hydro-Air UnitCall-for-Heat signal from a thermostat with user selected boiler supply target setpoint temperature optimized for hydro-air heating systems.
PEERLESS® PINNACLE®
Rev2
Control FeaturesDomestic Hot Water
Feature Description
DHW Tank Warm Hold
Prevents boiler from ramping up to high power if the DHW demand is only to keep the tank warm.
Limited DHW Priority
The PUREFIRE control provides DHW priority for boiler operation. However, the control will automatically switch between CH and DHW loads after an installer determined switch time.
DHW Heat DumpIf enabled, the DHW heat dump function serves to dump heat from the boiler system to the DHW tank after a CH demand has ended.
PEERLESS® PINNACLE®
Rev2
DHW Mode Choices
DHW Mode Display Text Description
0 No DHW No domestic hot water tank is used. (Factory Default)
1 DHW store with sensorThe domestic hot water tank is equipped with a temperature sensor. The PUREFIRE control modulates the boiler firing rate based on tank temperature.
2 DHW store with thermostat
The domestic hot water tank is equipped with a thermostat. The PUREFIRE control responds to the demand from the thermostat and modulates the boiler firing rate targeting the DHW boiler setpoint
PEERLESS® PINNACLE®
Rev2
Pump Mode Choices
Pump Mode
Display Text Description Detail
0DHW or CH & DHW pump
The General pump is on when the CH pump runs on CH demand. The DHW pump runs on DHW demand. Either the CH or DHW pump runs; they never run at the same time. (Factory Default)
1General pump with 3-way valve
The General pump is always on when burner is on. A line voltage (120 VAC) 3-way valve is operated to supply water to the DHW tank.
2Manifold with pump for DHW
The General pump is always on when the burner is on. The CH pump runs on CH demand. The DHW pump runs on DHW Demand. Either the CH or DHW pump runs; they never run at the same time.
PEERLESS® PINNACLE®
Rev2
Typical Cast Iron Boiler PipingParallel Piping Conversion to Primary/Secondary
PEERLESS® PINNACLE®
Rev2
Primary/Secondary PipingDHW Piped into Primary Loop
XX
Zone Relay
PEERLESS® PINNACLE®
Rev2
Primary/Secondary PipingDHW Piped into Boiler Loop
XX
Zone Relay
PEERLESS® PINNACLE®
Rev2
Low Voltage Wiring
PEERLESS® PINNACLE®
Rev2
Line Voltage Wiring
PEERLESS® PINNACLE®
Rev2
Wiring for PF-210 & PF-399
PEERLESS® PINNACLE®
Rev2
Line Voltage Wiring – High Amp Circ Pumps PureFire main control has a max amp draw of 5 amps including gas valve & other internal loads.
Total amp draw of all operating Circulators must be less than about 4.5 amps.
For example the General Circulator + the CH Circulator or the DHW circulator must be less than 4.5 amps.
If the circulator amp draw is higher than 4.5 amps, it must be isolated using a relay.
A RIB2401B relay may be used for circulator motors up to 1 horsepower.
The wiring schematic below shows how to wire isolation relays to the circulators.
PEERLESS® PINNACLE®
Rev2
Accessories
System Pipe SensorTo Aid in System Mixing
For Multiple Boiler Systems
DHW SensorFor Optional Control of Indirect Water Heater -
Control Tank Temp From Boiler
PEERLESS® PINNACLE®
Rev2
Accessories
Wall Mounting BracketNow Included with Boiler
For All Four Sizes:50, 80, 110, 140
Stainless Steel TableAdjustable Legs
PEERLESS® PINNACLE®
Rev2
Simple Fuel Conversion - LP & NG Conversion Kit Included with Every Boiler
No Orifices to Install or Remove
Spelled Out in the Conversion Kit:
Adjust Throttle Screw WITH CO/CO2 Meter
PEERLESS® PINNACLE®
Rev2
TESTING EQUIPMENT IS REQUIRED
Electronic CO/CO2 Combustion Analyzers are CRITICAL for Maintaining Safe & Efficient Operation of ANY 90+ Efficiency Equipment
Allowable Carbon Monoxide (CO) emission levels in Pinnacle flue gases: Hi-Fire <100 ppm
Lo-Fire < 20 ppm
PEERLESS® PINNACLE®
Rev2
All PureFire Boilers are Thoroughly Tested At the Factory
Factory Test Record Sheet Is Included with IOM Manual
PEERLESS® PINNACLE®
Rev2
More Control Features Maximum Input Limits
New in 2010
• Limit the Maximum Input on Any Boiler for Best Efficiency
• Limits can be on either Central Heating, DHW or Both with Their Own Limits
• Ideal for Applications Where DHW Load is Greater Than CH Load or Vice-Versa
• Boiler Can be Sized for Future Expansion Without Sacrificing Efficiency Now
PEERLESS® PINNACLE®
Rev2
Optional Boiler Interface BoardNew in 2010
• Allows boiler(s) to be connected to a Building Management System (BMS)
• Can be Used with Existing Boiler Control to Receive an External 0-10 Volt Signal to
Control Boiler Setpoint.
• Can be Used to Connect to an External Alarm for Boiler Shutdown Through Lockout or Block Error.
• Order as PFA-1 InterFace Board Kit (54271)
PEERLESS® PINNACLE®
Rev2
Optional Boiler Interface Board
PEERLESS® PINNACLE®
Rev2
Coming Soon: PC Software & USB Connection For Control
PEERLESS® PINNACLE®
Rev2
Ratings & Designations
•The PureFire™ Name has been Granted Trademark Status.
•PF50, PF80, PF110 & PF140 have been Approved for Mobil Homes and Manufactured Homes.
•PF50, PF80, PF110 & PF140 have been Certified to the Strict California Air Quality Standards (SCAQMD)
PEERLESS® PINNACLE®
Rev2
Selling PureFire
• Literature, Features and Benefits Sheets• Extended Warranties• Advertising Support• Custom ads available• PB Energy Calculator• Best Practices Training
PEERLESS® PINNACLE®
Rev2
PEERLESS® PINNACLE®
Rev2
PureFire Extended Warranty Program
• Standard Program -1 Yr parts and labor from 31st day after install
– Free if warranty card is returned
• PUREFIRE Introductory Program - $99 cost (PF50, 80, 110, 140
& PF210) or $179 (PF399) to Contractor/Dealer for a 5 Year
Parts and Labor Program - 10 Year program Cost - $279 (PF50,
80, 110, 140 & PF210) or $432 (PF399).
• Program Administered by CornerStone United, a US/Canadian
Warranty Administrator
* Installer MUST Sign Up to be Registered Warranty Dealer
PEERLESS® PINNACLE®
Rev2
PureFire Warranty Form & Extended Warranty Form
PEERLESS® PINNACLE®
Rev2
Parts of Peerless Extended Warranty Dealer Forms
PEERLESS® PINNACLE®
Rev2
Peerless Extended Warranty Brochure
PEERLESS® PINNACLE®
Rev2
Energy Saving Calculator• Used by Installers to Help Sell High Efficiency to
Homeowners by Showing Fuel Savings• Easy to Use 4-Step procedure with Slide Windows and Most Factors
Provided. Building Heat Loss & Fuel Type are Needed.
• Handy Size, Attractive and Loaded with Information
• Current Cost: $6 each (Oil Version & Natural Gas/LP Version) or $10
for both
PEERLESS® PINNACLE®
Rev2
AD Program for PureFire
• Custom ads on IMUS in the morning• Trade magazines• Local Meetings – Co-Op• PureFire PB Trailer for Live Fire Training• Trade Shows• Local Advertising Opportunities
PEERLESS® PINNACLE®
Rev2
PEERLESS® PINNACLE®
Rev2
Financing• What is EnergyLoan? • The EnergyLoan is a special
financing program offered by AFC First as a FannieMae Approved Energy Loan Lender and in cooperation with our Approved Contractor/Dealers.
• EnergyLoan is an unsecured loan program with preferential interest rates and terms designed to make fast and affordable financing from $1,000 to $20,000 available to homeowners for most types of improvements that improve the energy efficiency of your home.
• No Home Equity is Required - You can qualify even if you are a new homeowner.
• "No Payment for 3 Months" Deferred First Payment Available
• No Closing Costs - The EnergyLoan has no fees of any kind.
• Term of Up to 10 Years with No Pre-Payment Penalty - Lower payments, but the flexibility to pay extra principal or pay the loan off early.
• Rates of 9.99% to 12.99%
PEERLESS® PINNACLE®
Rev2
Payment CalculatorAMOUNT
3 Year 5 Year 10 Year
$2,500 $ 81 $ 56 $ 39
$5,000 $ 161 $ 111 $ 78
$7,500 $ 242 $ 167 $ 116
$10,000 $ 342 $ 233 $ 155
$12,500 $ 427 $ 291 $ 194
$15,000 $ 513 $ 349 $ 233
$17,500 $ 598 $ 407 $ 272
$20,000 $ 683 $ 465 $ 310
Estimated payment is based on interest rates ranging from 9.99% to 12.99% APR. Actual rate and payment depends on customer's credit, term and other factors
PEERLESS® PINNACLE®
Rev2
PEERLESS® PINNACLE®
Rev2
THE END
THANK YOU