Many States and Local Utilities Offer Additional Rebates

68

description

Many States and Local Utilities Offer Additional Rebates Visit www.dsireusa.org/incentives to Find Rebates in Your Area. Giannoni Stainless Steel Heat Exchanger Mono Block. Top Vent Outlet for Simplified Vent Connection. At the Heart of All - PowerPoint PPT Presentation

Transcript of Many States and Local Utilities Offer Additional Rebates

Page 1: Many States and Local Utilities Offer Additional Rebates
Page 2: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Page 3: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Many States and Local Utilities Offer Additional RebatesVisit www.dsireusa.org/incentives to Find Rebates in Your Area.

Page 4: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Page 5: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Giannoni Stainless Steel Heat ExchangerMono Block

Bottom-Up Burner Connection Helps Keep Flue Gasses from

Backing out at Shut-Down

Top Vent Outlet for Simplified Vent

Connection

At the Heart of AllPureFire Heat Exchangers - the Stainless Steel Loop –

Highly Resistant to Corrosion

Page 6: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Giannoni Stainless Steel Heat ExchangerMono Block

Separate Condensate Drain Connections for Heat Exchanger

& Vent Connectors

Boiler Return

(In)

Boiler Supply (Out)

Supply Sensor

Return Sensor

Drain/Purge Valve(Supplied)

Baffle in Manifold to Separate

Supply & Return Water

Page 7: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Removable Front Plastic Cover - Removable Metal Side PanelsWell-Sealed Cabinet - Prevents Combustion Odors which

Promotes Healthy Indoor AirTop Connections – Fuel, Piping Wiring & Venting

Sleek & Functional Mono Design

Main Control

Left Side Panel

Front Cover

Vent & Air Connections

Fuel Gas Connection

System Return (In)

System Supply (Out)

Service SwitchDisplay

Condensate System

Blower & Gas Valve

Page 8: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Duo Block DesignStainless Steel Heat Exchanger

Bottom-Up Burner Mounting Helps Keep Flue Gasses from

Backing out at Shut-Down

Duo Design Allows Smaller Boiler Footprint

Top Vent Outlet Connection

Page 9: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Mono Block Design:4 Inputs: 50, 80, 110 & 140

2 Cabinet Sizes

PureFire 50 & 80 PureFire 110 & 140

Page 10: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Duo Design ConceptCondensate Deflector

in Upper Chamber Eliminates the Need

For 2nd Connection on Condensate Collector,

which is Sealed with a Cap

Cooled Exhaust Gas OutletCooled Exhaust Gas Outlet

Condensate Drain

Condensate Deflector

Target Wall

Condensate Drain

Manifold with Return Inlet

&Supply Outlet

After Second Exchange

After First Exchange

Burner

Hot Flue Gas from BurnerCooled Flue Gas After Second Exchange

Cooled Flue Gas After First Exchange

Manifold Between Exchangers

Before Second Exchange

Co

nd

ensa

teD

rip

Return Water

Supply Water

Page 11: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Removable Metal Side Panels & Improved Cabinet Seals

Top Connections for Fuel, Venting & Wiring – 8 Knockouts

Lower Left Side Brass Piping Connections

New Duo PureFire Design Features

Page 12: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Duo Heat Exchanger Tappings

Boiler Supply (Out)

Boiler Return

(In)

Return Sensor

Supply Sensor

Relief Valve

Drain/Purge Valve(Inside)

Flue Gas Sensor(Other Side)

Vent Pressure Switch(Front Side)

⅝” CondensateConnection

Baffle in Manifold to Separate Supply & Return Water

Page 13: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Duo Block Design - Inputs: 210 & 399mbh 2 Cabinet Sizes

Page 14: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

PureFire 210 & 399 Ratings

Boiler Model

Input (MBH)Heating Capacity (MBH)

Net I=B=R Ratings (MBH)

AFUE (%)Appx Shipping Weight (lbs)

Minimum Maximum

PF-210 42 210 192 167 97.3 160

Boiler ModelInput (MBH) Gross

Output (MBH)

Net I=B=R Ratings (MBH)

Thermal Efficiency (%)

Combustion Efficiency (%)

Appx Shipping Weight (lbs)

Minimum Maximum

PF-399 80 399 373 324 93.4 95.5 250

• 5:1 Turndown Ratio• Can Be Higher When Approval Agencies Raise Maximum• Higher Turndown with Large Inputs Are More Reliable & Have a Greater Impact on Efficiency• Vent Length As Much As 200’ Total Equivalent • Circulators

PF-210 – Taco 0014 or Grundfos UPS 26-99FCPF-399 – Taco1400-20 or Grundfos UP 32-80F

Page 15: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Full-Featured & Easy-To-Use Boiler Control

with Plain English Text Display No Need to Memorize Codes

Most Features are Pre-Programmed & Ready-to-go

Page 16: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

New Features Scheduled for Release withPF-210 & PF-399 in 2009

Display Main Control

Same Location for Display As Mono Block Design

New Location for Main Control for Easy Access

Page 17: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

All PureFire Boiler Controls Use Fuse Protection- Easily Replaceable Fuse -

Main Control

Fuse Size = 5mm x 20mm, 250 Volt, Slow Blow

Available at Radio Shack (Part# 270-1067) 4-Pack - $2.99

Page 18: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Molded Plastic JacketWith Tinted Clear Lens for Viewing Control Display

Page 19: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

EBM-Papst Blowers Dungs Gas Valves

Extensively Field-Tested by Peerless

Patented Whirlwind Technology Promotes Better

Fuel/AirMixing for Better Combustion

Various Swirl Plates for Different Boiler Sizes

Page 20: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Dungs Gas Valve Operation

Adjust CO2 ONLY with Throttle Screw

Gas valves are preset at factory for fuel type

Fuel Pressure can be measured at Inlet Pressure Tap

Page 21: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Worgas Metal Mesh BurnersProvide Stable and Reliable Flame

Igniters & Flame SensorsProvide Dual Sensing of Burner Flame – Help Prevent Unnecessary Lockouts

Page 22: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Molded Plastic Vessels for Condensate Collection & Neutralizing

Optional for PF-210 & 399

Page 23: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Simplified Electrical ConnectionsPre-Wired Harnesses & Split Terminal Strips

Page 24: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Additional Features

Leveling Legs Courtesy Outlet

Page 25: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Features

Outdoor SensorFor Outdoor Reset

(Supplied as Standard Equipment)

Knock-out GrommetFor Low-Voltage WiresHelps Protect Wires &Keep Cabinet Sealed

Page 26: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Venting Options: PVC, CPVC & PP (M&G)with Stainless Steel, Concentric PVC & PP Termination Options

Page 27: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Control DisplaySample Screens

Page 28: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Control DisplaySample Screens

Page 29: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Control Features

Feature Description

Cascade Multiple boilers operate together in order to satisfy the heating or DHW demand.

One Hour RetryOne hour after a lockout on ignition or flame failure, the PUREFIRE control will reinitiate boiler operation.

Restore System Defaults

Allows the installer to reset all parameters to the factory defaults if desired. The installer can also save and restore site defaults.

Adjustable Blower Postpurge

This feature allows the installer to increase the blower postpurge to counteract the effects of high winds or unusual wind currents.

Flame Signal LogThis troubleshooting tool captures the flame signal at four increments during the two second flame proving period. This can help installers/service personnel to quickly diagnose problems with flame rectifications.

Fault HistoryThe PUREFIRE control allows service personnel to access the last 15 Blocking Errors and the last 15 Lockout Errors in addition to records of the interval between Errors.

New or Enhanced in 2009

Page 30: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

New Control Features Cascade Firing of Multiple Boilers

• Control up to16 Boilers in One System

• No Extra Controls Required, Only 1 System Sensor

• Automatic Rotation of Boilers (Lead/Lag)

• No Extensive Programming Required

- Most Options Are Pre-Selected, But Adjustable

• Boilers will be Fired Proportionally with Timed Start and

Stop for Maximum Efficiency & Longevity

• All PureFire™ Boilers will be Cascade Capable

- After the Release of the new PF-210 & PF-399

- Existing PF Boilers Can Be Easily Upgraded

• New Controls will be Compatible with Older Displays &

Vice Versa

Page 31: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Cascade Functions with Multiple Boilers

• The Control on Any Boiler can be the Master Control

• Simple Instructions Explain How to Designate the Master

Control and All Dependent Controls

• All Sensors and Non-Boiler Pumps are Wired to the Master

• Control & Status of All Boilers Including Resets can be

Done Through Master

• Each Dependent Boiler Controls Only Its Own Pump

• Boiler Controls are Interconnected in Parallel with only 1 Set of

Thermostat Wires Between Each Boiler

• Future PC Connections can be made to Any Dependent Control

Page 32: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Control FeaturesSafety & Efficiency

Feature Description

Freeze ProtectionActivates pumps if temperatures fall below the specified value. If the temperatures continue to fall, the boiler is activated.

Ramp Delay Step Modulation

This feature is used to prevent short cycling in systems using very small zones. The input rate is gradually increased from 20% to 100% over 2 minutes. When used, this only effects central heating operation.

Add’l Safety Functions

Allows the installer to choose between a low water cutoff and a flow switch for water level safety shutdown.

Vent Temperature Safety Limit

Reduces the firing rate if the vent temperature approaches the maximum limit of the vent material. If the vent temperature continues to climb, the PUREFIRE control will shut down the boiler.

Service Notification

If enabled, the PUREFIRE control will display a service notification after an installer defined number of hours or cycles. It can also display a notification based on a date of the installers choosing.

System TestThe PUREFIRE boiler will allow the installer to operate the boiler at low power, high power and ignition input for troubleshooting purposes.

Page 33: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Control FeaturesCentral Heating

Feature Description

Outdoor ResetThe PUREFIRE control changes the boiler supply target temperature to compensate for changes in load due to milder outdoor temperatures. This increases the efficiency of the boiler and is more comfortable.

System Type Presets

By choosing the heat distribution type (finned tube baseboard, hydro air, cast iron radiators, cast iron baseboard, low mass radiant or high mass radiant) the installer can automatically select practical boiler design and mild weather temperatures.

Temperature Boost

The temperature boost function increases the boiler supply target to recover more quickly from setback conditions.

Warm Weather Shutdown

The PUREFIRE control will shut down the boilers CH functions if the outdoor temperature is above an installer defined maximum. This prevents the boiler from running during warm weather.

Anti-CyclingThe anti-cycling function prevents rapid on/off cycling of the boiler. This includes an override function to be sure that all loads are satisfied.

Page 34: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Outdoor Reset

Page 35: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Central Heating Mode ChoicesCH Mode Display Text Description

0 Indoor ThermostatCall-for-Heat signal from thermostat with user selected boiler supply target setpoint temperature. (Factory Default)

1Thermostat and Outdoor Reset

Call-for-Heat signal from thermostat with boiler supply target temperature calculated using outdoor temperature.

2 Full Outdoor ResetContinuous heat demand with boiler supply target temperature calculated using outdoor temperature.

3 Permanent Demand Continuous heat demand with user selected boiler supply target temperature.

40-10 V Input to modulate Setpoint

This mode is not available at this time.

5 0-10 V Input to modulate Rate

This mode is not available at this time.

6 Hydro-Air UnitCall-for-Heat signal from a thermostat with user selected boiler supply target setpoint temperature optimized for hydro-air heating systems.

Page 36: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Control FeaturesDomestic Hot Water

Feature Description

DHW Tank Warm Hold

Prevents boiler from ramping up to high power if the DHW demand is only to keep the tank warm.

Limited DHW Priority

The PUREFIRE control provides DHW priority for boiler operation. However, the control will automatically switch between CH and DHW loads after an installer determined switch time.

DHW Heat DumpIf enabled, the DHW heat dump function serves to dump heat from the boiler system to the DHW tank after a CH demand has ended.

Page 37: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

DHW Mode Choices

DHW Mode Display Text Description

0 No DHW No domestic hot water tank is used. (Factory Default)

1 DHW store with sensorThe domestic hot water tank is equipped with a temperature sensor. The PUREFIRE control modulates the boiler firing rate based on tank temperature.

2 DHW store with thermostat

The domestic hot water tank is equipped with a thermostat. The PUREFIRE control responds to the demand from the thermostat and modulates the boiler firing rate targeting the DHW boiler setpoint

Page 38: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Pump Mode Choices

Pump Mode

Display Text Description Detail

0DHW or CH & DHW pump

The General pump is on when the CH pump runs on CH demand. The DHW pump runs on DHW demand. Either the CH or DHW pump runs; they never run at the same time. (Factory Default)

1General pump with 3-way valve

The General pump is always on when burner is on. A line voltage (120 VAC) 3-way valve is operated to supply water to the DHW tank.

2Manifold with pump for DHW

The General pump is always on when the burner is on. The CH pump runs on CH demand. The DHW pump runs on DHW Demand. Either the CH or DHW pump runs; they never run at the same time.

Page 39: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Typical Cast Iron Boiler PipingParallel Piping Conversion to Primary/Secondary

Page 40: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Primary/Secondary PipingDHW Piped into Primary Loop

XX

Zone Relay

Page 41: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Primary/Secondary PipingDHW Piped into Boiler Loop

XX

Zone Relay

Page 42: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Low Voltage Wiring

Page 43: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Line Voltage Wiring

Page 44: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Wiring for PF-210 & PF-399

Page 45: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Line Voltage Wiring – High Amp Circ Pumps PureFire main control has a max amp draw of 5 amps including gas valve & other internal loads.

Total amp draw of all operating Circulators must be less than about 4.5 amps.

For example the General Circulator + the CH Circulator or the DHW circulator must be less than 4.5 amps.

If the circulator amp draw is higher than 4.5 amps, it must be isolated using a relay.

A RIB2401B relay may be used for circulator motors up to 1 horsepower.

The wiring schematic below shows how to wire isolation relays to the circulators.

Page 46: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Accessories

System Pipe SensorTo Aid in System Mixing

For Multiple Boiler Systems

DHW SensorFor Optional Control of Indirect Water Heater -

Control Tank Temp From Boiler

Page 47: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Accessories

Wall Mounting BracketNow Included with Boiler

For All Four Sizes:50, 80, 110, 140

Stainless Steel TableAdjustable Legs

Page 48: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Simple Fuel Conversion - LP & NG Conversion Kit Included with Every Boiler

No Orifices to Install or Remove

Spelled Out in the Conversion Kit:

Adjust Throttle Screw WITH CO/CO2 Meter

Page 49: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

TESTING EQUIPMENT IS REQUIRED

Electronic CO/CO2 Combustion Analyzers are CRITICAL for Maintaining Safe & Efficient Operation of ANY 90+ Efficiency Equipment

Allowable Carbon Monoxide (CO) emission levels in Pinnacle flue gases: Hi-Fire <100 ppm

Lo-Fire < 20 ppm

Page 50: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

All PureFire Boilers are Thoroughly Tested At the Factory

Factory Test Record Sheet Is Included with IOM Manual

Page 51: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

More Control Features Maximum Input Limits

New in 2010

• Limit the Maximum Input on Any Boiler for Best Efficiency

• Limits can be on either Central Heating, DHW or Both with Their Own Limits

• Ideal for Applications Where DHW Load is Greater Than CH Load or Vice-Versa

• Boiler Can be Sized for Future Expansion Without Sacrificing Efficiency Now

Page 52: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Optional Boiler Interface BoardNew in 2010

• Allows boiler(s) to be connected to a Building Management System (BMS)

• Can be Used with Existing Boiler Control to Receive an External 0-10 Volt Signal to

Control Boiler Setpoint.

• Can be Used to Connect to an External Alarm for Boiler Shutdown Through Lockout or Block Error.

• Order as PFA-1 InterFace Board Kit (54271)

Page 53: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Optional Boiler Interface Board

Page 54: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Coming Soon: PC Software & USB Connection For Control

Page 55: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Ratings & Designations

•The PureFire™ Name has been Granted Trademark Status.

•PF50, PF80, PF110 & PF140 have been Approved for Mobil Homes and Manufactured Homes.

•PF50, PF80, PF110 & PF140 have been Certified to the Strict California Air Quality Standards (SCAQMD)

Page 56: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Selling PureFire

• Literature, Features and Benefits Sheets• Extended Warranties• Advertising Support• Custom ads available• PB Energy Calculator• Best Practices Training

Page 57: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Page 58: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

PureFire Extended Warranty Program

• Standard Program -1 Yr parts and labor from 31st day after install

– Free if warranty card is returned

• PUREFIRE Introductory Program - $99 cost (PF50, 80, 110, 140

& PF210) or $179 (PF399) to Contractor/Dealer for a 5 Year

Parts and Labor Program - 10 Year program Cost - $279 (PF50,

80, 110, 140 & PF210) or $432 (PF399).

• Program Administered by CornerStone United, a US/Canadian

Warranty Administrator

* Installer MUST Sign Up to be Registered Warranty Dealer

Page 59: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

PureFire Warranty Form & Extended Warranty Form

Page 60: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Parts of Peerless Extended Warranty Dealer Forms

Page 61: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Peerless Extended Warranty Brochure

Page 62: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Energy Saving Calculator• Used by Installers to Help Sell High Efficiency to

Homeowners by Showing Fuel Savings• Easy to Use 4-Step procedure with Slide Windows and Most Factors

Provided. Building Heat Loss & Fuel Type are Needed.

• Handy Size, Attractive and Loaded with Information

• Current Cost: $6 each (Oil Version & Natural Gas/LP Version) or $10

for both

Page 63: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

AD Program for PureFire

• Custom ads on IMUS in the morning• Trade magazines• Local Meetings – Co-Op• PureFire PB Trailer for Live Fire Training• Trade Shows• Local Advertising Opportunities

Page 64: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Page 65: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Financing• What is EnergyLoan? • The EnergyLoan is a special

financing program offered by AFC First as a FannieMae Approved Energy Loan Lender and in cooperation with our Approved Contractor/Dealers.

• EnergyLoan is an unsecured loan program with preferential interest rates and terms designed to make fast and affordable financing from $1,000 to $20,000 available to homeowners for most types of improvements that improve the energy efficiency of your home.

• No Home Equity is Required - You can qualify even if you are a new homeowner.

• "No Payment for 3 Months" Deferred First Payment Available

• No Closing Costs - The EnergyLoan has no fees of any kind.

• Term of Up to 10 Years with No Pre-Payment Penalty - Lower payments, but the flexibility to pay extra principal or pay the loan off early.

• Rates of 9.99% to 12.99%

Page 66: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Payment CalculatorAMOUNT

3 Year 5 Year 10 Year

$2,500 $ 81 $ 56 $ 39

$5,000 $ 161 $ 111 $ 78

$7,500 $ 242 $ 167 $ 116

$10,000 $ 342 $ 233 $ 155

$12,500 $ 427 $ 291 $ 194

$15,000 $ 513 $ 349 $ 233

$17,500 $ 598 $ 407 $ 272

$20,000 $ 683 $ 465 $ 310

Estimated payment is based on interest rates ranging from 9.99% to 12.99% APR. Actual rate and payment depends on customer's credit, term and other factors

Page 67: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

Page 68: Many States and Local Utilities Offer Additional Rebates

PEERLESS® PINNACLE®

Rev2

THE END