manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping...

7
UNIVER GROUP Automotive U N M 5 0 N N 1 3 4 5 K 6 N H 7 4 7 5 1 3 2 2 6 UNM50 Automotive Serie Taglia Versione UN = Unità di bloccaggio UNIVERSAL standard NAAMS con regolazione continua angolo d’apertura da: 0° a 135° max M = Pneumatica con azionamento manuale 50 = Ø 50 mm Posizione pressore Filetto alimentazioni Uscita albero quadro Sensore di posizione N = Senza sensore (con piastra di chiusura) K = Sensore elettronico PNP (ottico) (DF-K) N = Senza pressore Unità di bloccaggio UNIVERSAL con azionamento manuale standard NAAMS R L N = Singolo lato destro = Singolo lato sinistro = Entrambi i lati G = Gas NH = NPT NW_Rev. 00_0820

Transcript of manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping...

Page 1: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNIVER GROUP Automotive

U N M 5 0 N N1 3 4 5

K6

N H7

4

7

5

1 32

2

6

UNM50

Automotive

Serie TagliaVersione

UN = Unità di bloccaggio UNIVERSAL

standard NAAMS con regolazione continua angolo d’apertura da:

0° a 135° max

M = Pneumaticacon azionamento manuale

50 = Ø 50 mm

Posizione pressore

Filetto alimentazioni

Uscita albero quadro Sensore di posizione

N = Senza sensore (con piastra di chiusura)K = Sensore elettronico PNP (ottico) (DF-K)

N = Senza pressore

Unità di bloccaggio UNIVERSAL con azionamentomanuale standard NAAMS

RLN

= Singolo lato destro= Singolo lato sinistro= Entrambi i lati

G = GasNH = NPT

NW_Rev. 00_0820

Page 2: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNM50NNKG

50 mm 1250 Nm 280 Nm 3,5 Kg

Rev. 00 26.08.20

Min./Max. operating pressure: 0,4 / 0,6 MPa

Operating temperature: 5° ÷ 45° C

Opening angle: adjustable

Without armWith manual leverElectronic sensor with M12 swivel connector, from 0° to 90°Supply voltage: 10 ÷ 30 VdcIP code: IP 65

Pneumatic ports on both sides

UNIVERSAL Power clamps

Bore

Ø

Holding

moment

Clamping moment

(0,5 MPa)

Weight

(clamping arm not included)

* : TOLERANCE BETWEEN DOWELS ± 0,02, BETWEEN SCREW HOLES ± 0,1**: THE MEASURES REFER TO NAAMS STANDARD***: AREA TO ACCESS ANGLE ADJUSTMENT****: DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED

Subject to technical modifi cations without notice

Page 3: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNM50NNKNH

50 mm 1250 Nm 280 Nm 3,5 Kg

Rev. 00 04.05.20

Min./Max. operating pressure: 0,4 / 0,6 MPa

Operating temperature: 5° ÷ 45° C

Opening angle: adjustable

Without armWith manual leverElectronic sensor with M12 swivel connector, from 0° to 90°Supply voltage: 10 ÷ 30 VdcIP code: IP 65

Pneumatic ports on both sides

Bore

Ø

Holding

moment

Clamping moment

(0,5 MPa)

Weight

(clamping arm not included)

* : TOLERANCE BETWEEN DOWELS ± 0,02, BETWEEN SCREW HOLES ± 0,1**: THE MEASURES REFER TO NAAMS STANDARD***: AREA TO ACCESS ANGLE ADJUSTMENT****: DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED

Subject to technical modifi cations without notice

UNIVERSAL Power clamps

Page 4: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNM50NLKG

50 mm 1250 Nm 280 Nm 3,5 Kg

Rev. 00 26.08.20

Min./Max. operating pressure: 0,4 / 0,6 MPa

Operating temperature: 5° ÷ 45° C

Opening angle: adjustable

Without armWith manual leverElectronic sensor with M12 swivel connector, from 0° to 90°Supply voltage: 10 ÷ 30 VdcIP code: IP 65

Pneumatic ports on both sides

Bore

Ø

Holding

moment

Clamping moment

(0,5 MPa)

Weight

(clamping arm not included)

* : TOLERANCE BETWEEN DOWELS ± 0,02, BETWEEN SCREW HOLES ± 0,1**: THE MEASURES REFER TO NAAMS STANDARD***: AREA TO ACCESS ANGLE ADJUSTMENT****: DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED

Subject to technical modifi cations without notice

UNIVERSAL Power clamps

Page 5: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNM50NLKNH

50 mm 1250 Nm 280 Nm 3,5 Kg

Rev. 00 26.08.20

Min./Max. operating pressure: 0,4 / 0,6 MPa

Operating temperature: 5° ÷ 45° C

Opening angle: adjustable

Without armWith manual leverElectronic sensor with M12 swivel connector, from 0° to 90°Supply voltage: 10 ÷ 30 VdcIP code: IP 65

Pneumatic ports on both sides

Bore

Ø

Holding

moment

Clamping moment

(0,5 MPa)

Weight

(clamping arm not included)

* : TOLERANCE BETWEEN DOWELS ± 0,02, BETWEEN SCREW HOLES ± 0,1**: THE MEASURES REFER TO NAAMS STANDARD***: AREA TO ACCESS ANGLE ADJUSTMENT****: DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED

Subject to technical modifi cations without notice

UNIVERSAL Power clamps

Page 6: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNM50NRKG

50 mm 1250 Nm 280 Nm 3,5 Kg

Rev. 00 26.08.20

Min./Max. operating pressure: 0,4 / 0,6 MPa

Operating temperature: 5° ÷ 45° C

Opening angle: adjustable

Without armWith manual leverElectronic sensor with M12 swivel connector, from 0° to 90°Supply voltage: 10 ÷ 30 VdcIP code: IP 65

Pneumatic ports on both sides

Bore

Ø

Holding

moment

Clamping moment

(0,5 MPa)

Weight

(clamping arm not included)

* : TOLERANCE BETWEEN DOWELS ± 0,02, BETWEEN SCREW HOLES ± 0,1**: THE MEASURES REFER TO NAAMS STANDARD***: AREA TO ACCESS ANGLE ADJUSTMENT****: DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED

Subject to technical modifi cations without notice

UNIVERSAL Power clamps

Page 7: manuale standard NAAMS - UNIVER GROUP · UNIVERSAL Power clamps Bore Ø Holding moment Clamping moment (0,5 MPa) Weight (clamping arm not included) * : TOLERANCE BETWEEN DOWELS ±

UNM50NRKNH

50 mm 1250 Nm 280 Nm 3,5 Kg

Rev. 00 26.08.20

Min./Max. operating pressure: 0,4 / 0,6 MPa

Operating temperature: 5° ÷ 45° C

Opening angle: adjustable

Without armWith manual leverElectronic sensor with M12 swivel connector, from 0° to 90°Supply voltage: 10 ÷ 30 VdcIP code: IP 65

Pneumatic ports on both sides

Bore

Ø

Holding

moment

Clamping moment

(0,5 MPa)

Weight

(clamping arm not included)

* : TOLERANCE BETWEEN DOWELS ± 0,02, BETWEEN SCREW HOLES ± 0,1**: THE MEASURES REFER TO NAAMS STANDARD***: AREA TO ACCESS ANGLE ADJUSTMENT****: DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED

Subject to technical modifi cations without notice

UNIVERSAL Power clamps