Manual de Instruções para Bomba de Transferência F4B-11 ... de Lastro F4B... · Em caso dúvidas...
Transcript of Manual de Instruções para Bomba de Transferência F4B-11 ... de Lastro F4B... · Em caso dúvidas...
Manual de Instruções para
Bomba de Transferência F4B-11 Johnson Pump
Em caso dúvidas na instalação após a leitura do manual, favor entrar em
contato com nosso departamento técnico através do telefone ou email:
• (11) 3477-5655�
• email: [email protected]
Horários de atendimento:
Segunda-feira à quinta-feira: 8h – 18h
Sexta-feira: 8h – 17h
Rua Anhaia 982, Bom Retiro – SP
www.marineoffice.com.br
I N STR UCTION MAN UAL
OR IG I NAL I N STR UCTION S /TRAN S LATION OF OR IG I NAL I N STR UCTION S
R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S
PROD UCT
Flexible Impeller Pump Ultra BallastF4B-11 12/24 V DC
I B-410 R04 (12/2015)
7Original instructions
> English
Ultra Ballast — Self-priming, flexible impeller pumpflange mounted to DC motor 12/24 V
Typical applicationsThe Ultra Ballast Pump has been designed to pump water into ballast tanks. When reversed it will also pump water out of them.The pump can be obtained with an MC-97 impeller and a Polyurethane impeller.
Design featuresBody: BronzeImpeller: MC 97 rubber or polyurethaneSeal: Lip seal, NBR rubber or PolyurethaneO-ring: NBR rubberConnection: ½” Internal BSP/NPT or 1” hose (ø 25 mm)Liquidtemperature: Max +55°CMotor: 0,25 kW, 12/24 V DC with built in thermal protection Total enclosed ReversibleShaft: Stainless steelBearings: Permanent lubricated, sealed, ball bearings
The motor is ignition protected according to ISO 8846 (Small craft - Electrical devices - Protection against ignition of surrounding flammable gases).
Type designationType Part No F4B-12 (BSP) polyurethane impeller 12V 10-24690-09F4B-12 (BSP) polyurethane impeller 24V 10-24690-10F4B-1207 (NPTF) polyurethane impeller 12V 10-24690-11F4B-1207 (NPTF) polyurethane impeller 24V 10-24690-12
Pressure and capacity data (based on water at 20°C and at nomi-nal voltage of the motor)
Installation and maintenance
InstallationPump should be mounted in a dry, cool ventilated location.Pump may be mounted in any position without loss of efficiency; however, it is suggested that the pump head be down if vertical mounting is desired. Mount motor as close as possible to power source to obtain full voltage. The pump should be installed so that the motor is protected from rain, wash down or bilge water.Please note that pump body can be turned 180° in relation to motor. This changes flow direction.When using a vac-on-switch, mount it on the connection on the inlet side of the pump. When using a pressure switch, mount it on the connection on the outlet side of the pump.Don’t handle diesel fuel or other mineral oils with this pump. (For these liquids use pump type F4B-19)This pump cannot run against a closed outlet. Risk for overheating.
MC97PressureBar kPa psi l/min USGM 12V 24V0 0 0,0 54 14,0 14,5 70,1 10 1,5 53 13,8 15 7,50,3 30 4,4 49 12,7 16 80,6 60 8,7 44 11,4 18 90,9 90 13,1 38 9,9 20 101,2 120 17,4 31 8,1 22 111,5 150 21,8 22 5,7 24 12PolyurethanePressureBar kPa psi l/min USGM 12V 24V0 0 0,0 52 13,5 12 4,80,1 10 1,5 50 13,0 12,5 4,90,3 30 4,4 47 12,2 12,7 5,50,6 60 8,7 39 10,1 15,5 6,20,9 90 13,1 29 7,5 16,2 6,81,2 120 17,4 15 3,9 17,5 7,3
Ampere
8 Original instructions
> English
PlumbingUse hose that does not kink when bent, and also with sufficient wall thickness preventing collapse when used on suction side, eg. reinforced hoses.Hoses should be routed so that some water will remain in pump body to wet impeller for easy start up.Use a strainer at intake hose to prevent from trash and solids entering the pump. In order to ensure good priming always keep connections airtight.
Electrical installationThe pump must be installed according to ISO 10133 (Small craft - Electrical system - Extra low voltage DC installation for continuous current). Note: The fuse must be ignition protected.The motor is equipped with built in ther-mal protection to prevent the motor from overheating. The protection is automati-cally restored when the motor is cooled.If the pump is connected with separate earth lead, this should be yellow/green and connected to the motor base.See the wiring table for correct installation. Choose wire size in accordance with total wire length (see table beside).The pump should be operated by a Polarity Reversing switch, through an over current protected distribution panel fitted with a 25 Amp/12V or 15 Amp/24V breaker or fuse.The wire connections must be sealed.Note: Before installation with electrical control systems, check that equipment to be used is of sufficient rated capacity to accept ampere draw of motor.
Wiring Table
+-
Black
Pump
Terminal fuse or overloadProtected Distribution Panel
Polarity Reversing Switch pt.no 01-47196
Red
Green/Yellow
Black
Bottom view of terminalarrangement
8
65
4
21To
mot
or re
d
To m
otor
bla
ck
To b
atte
ry (+
) pos
.
To b
atte
ry (-
) neg
.
8 2 46
Max 0,2 m
Wiring dimensions(based on 3% voltage drop)
Wire size Max wire lenght* in m 12V 24V2,5 mm² # 14 AWG 2,7 114 mm² # 12 AWG 4,4 17,66 mm² # 10 AWG 6,6 26,310 mm² # 6 AWG 11 16 mm² # 4 AWG 17,6 25 mm² # 2 AWG 27,4
*The wire length is the total distance from the battery to the pump and back to the battery. It is recommended to use a relay to shorten the main leaders.
OperationThe Ultra Ballast pump is reversible so it can both add liquid ballast and then pump it overboard when needed. As an alternative you may pump liquid ballast from one tank to another and reversed. At need for adding ballast you flip the switch to fill position and watch for indica-tors that tank is full, then switch pump off.To reduce ballast, flip switch to drain position. The pump will reverse to pump ballast back over board. Watch indicator for an empty tank and switch pump off. The same operation is used for ballast transfer between two tanks.
9Original instructions
> English
Self-priming (refers MC97-impeller)Pump is self-priming up to 4 m. Intake lines must be air-tight to ensure self-priming. Note: Pump will prime when impeller is dry but suction lift up to 4 m is only obtainable when impeller is lubricated with liquid being pumped or Johnson Impeller Lubricant. For permanent installations where suction lift exceeds 4 m, a foot valve should be used to assure priming on start up. ALWAYS USE JOHNSON IMPELLER LUBRICANT (glycerin) for impeller lubri-cation. Never use grease or mineral oils.
Self-priming (refers polyurethane impeller) The pump is self-priming up to 1.5 metres provided that the suction pipe is absolutely airtight. Note! The pump is self-priming when the impeller is dry, but to obtain suction heads up to 1.5 metres the impeller must be lubricated with the liquid to be pumped or Johnson Impeller Lubricant. For a permanent installation where the suction head exceeds 1.5 metres a foot valve should be fitted to ensure the pump can provide suction immediately after starting. ALWAYS USE JOHNSON IMPELLER LUBRICANT (glycerin) for lubricating the impeller. Never use grease or mineral oils.
Continuous dutyFor continuous duty 0,6 bar (60 kPa, 8,5 psi) maximum head is permissible. Max ambient temp is +60°C.
Dry runningDo not run dry for more than 30 seconds. Lack of liquid will burn the impeller and damage the seals.
Caution. Explosion Hazard.Do not pump gasoline, solvents, thinners or other flammable liquids.Do not handle highly concentrated or organic acids.
Caution. Explosion Hazard.Never operate a motor which in any way has been manipulated and lost it’s full enclosure.
Temperature Max ambient temperature: +60°C.The life of the impeller depends on the temperature of liquid being pumped. Tem-peratures between +5°C and +55°C give normal life. Higher or lower temperature will reduce the life.
Caution. The normal working temperature of the motor may reach approx. +80°C (surface temperature) which may burn your skin.
Freezing weather Drain unit by loosening the end cover. Glycol based anti-freezes can be used but do not use petroleum based anti-freeze compounds.
Waste handling/material recyclingAt the product’s end of life please dispose of the product according to applicable law. Where applicable please disassemble the product and recycle the parts material.
Service instructions (see page27-28)
Disassembly1. Back off the endcover screws (7), re- move the endcover (5) and O-ring (6).2. Pull out the impeller (3) using a slip joint plier.3. Back off and remove the nuts (8) and washers (9) holding the body. Separate the body from the motor.4. Remove the lip seal (4).5. Do not disassemble the motor.
10 Original instructions
> English
Assembly1. Moisten the new lip seal with soapy water (5% soft soap), mount the seal with the lip facing towards the impeller.2. Lubricate the motor shaft with glycerin of the like. Fit the body to the motor.3. Lubricate inside the pump body where the impeller should be placed with Johnson Impeller Lubricant, provided with the spare Impeller. Also lubricate the surface of the end cover. Never use grease or mineral oils for lubrication.
4. Fit the impeller with a rotating movement in the intended direction of the pump rotation.5. Lubricate the O-ring with glycerin and fit it in its position and fasten the end cover.
Waste handling/ material recyclingAt the products end of life, please dis-pose of the product according to ap-plicable law. Where applicable, please disassemble the product and recycle the parts material.
ImpellerThe impeller, pt.no. 09-824P-1 (MC-97) or 09-824P-2 (polyurethane), is a very important security device and should be replaced every year with a Johnson original impeller.Always lubricate Impeller at replace-ment with Johnson Impeller Lubricant, provided with the spare kit.
AccessoriesPolarity Reversing Switch KitPart No. 09-47196
27
ReservdelslistaParts listTeilliste
Pos Nos Benämning Description Bezeichnung Art No
1 1 Pumphus (-19) Body (-19) Gehäuse (-19) 01-24452-1 Pumphus (-1907) Body (-1907) Gehäuse (-1907) 01-24452-2 2 1 Motor 12 V Motor 12 V Motor 12 V 01-24676-01 Motor 24 V Motor 24 V Motor 24 V 01-24676-02 3 1 Impeller Impeller Impeller 09-824P-1 4 1 Läpptätning Lip seal Lippendichtung 0.2233.007 5 1 Lock Endcover Deckel 01-42398 6 1 O-ring O-ring O-Ring 0.2173.476 7 6 Skruv Screw Schraube 0.0279.501 8 2 Mutter Nut Mutter 0.0185.068 9 2 Bricka Washer Scheibe 0.0353.208 10 1 O-ring O-ring O-Ring 0.2173.470 11 2 Plugg Plug Stopfen 0.2500.805 12 4 Fot kit Foot kit Fuß 09-47194 1 Service kit Service kit Ersatzteilsatz 09-47193
Pos Nos Description Descripción Descrizione Art No
1 1 Corps (-19) Cuerpo (-19) Corpo (-19) 01-24452-1 Corps (-1907) Cuerpo (-1907) Corpo (-1907) 01-24452-2 2 1 Moteur 12 V Motor 12 V Motore 12 V 01-24676-01 Moteur 24 V Motor 24 V Motore 24 V 01-24676-02 3 1 Rotor Propulsor Girante 09-824P-1 4 1 Joint à lèvre Junta de labio Corteco 0.2233.007 5 1 Couvercle Cubierta Coperchio 01-42398 de extremo 6 1 Joint torique Junta tórica O-Ring 0.2173.476 7 6 Vis Tornillo Vite 0.0279.501 8 2 Ecrou Tuerca Dado 0.0185.068 9 2 Rondelle Arandela Rondella 0.0353.208 10 1 Joint torique Junta tórica O-Ring 0.2173.470 11 2 Bouchon Tapón Presa 0.2500.805 12 4 Kit de plot élastique Kit de pie Kit di piede 09-47194 1 Kit de reparation Kit de Kit di servizio 09-47193 mantenimiento
Liste des piècesLista de piezas
Elenco delle parti
**
**
**
**
*
*
28
Vikt 3 kgWeight 3 kgGewicht 3 kgPoids 3 kgPeso 3 kg
Dim. mm
IN
NIARDOTREVOC
IN
ROTATION
L
SWEDEN
O
JOHNSON PUMP AB
OSEN
1000±10
Ø25,4
G
120
34 (2x)
2
5545±1,5
12
7 5 6 11 3 1 4 89
10 14
12
2 13
208
61
WasherØ5,3/20x1,5
Spacer sleeve
Rubber foot
16,5
5Ø