    User Manual

    Chongqing Jinghong High-Tech Co., Ltd.

  • 8/10/2019 Manual CMTS

    2/20

    JH-HE2086 CMTS user manual

    Catalog

    Copyright Declaration ........................................................................................................................2

    Foreword ..............................................................................................................................3

    Packaging introduction.......................................................................................................................4

    JH-HE 2086 CMTS Operation Guide ...................................................................................................6

    Summary .........................................................................................................................................6 .1

    Brief Introduction .......................................................................................................................6 .2

    Features ......................................................................................................................................6 .3Index...............................................................................................................................................8

    CMTS equipment ports ...................................................................................................................9.1

    The appearance ..............................................................................................................................9.2

    The rear panel................................................................................................................................10.3

    Front panel indicator light ............................................................................................................10.4

    Getting started..........................................................................................................................11.1

    Cable connection.......................................................................................................................11.2

    Request of correlation servers...................................................................................................13.3

    Turn on and turn off ...................................................................................................................14

    Equipment parameter configuration ........................................................................................14.1

    Factory setting parameters ......................................................................................................14.2

    Startup steps of the equipment ...............................................................................................15.3

    Configure the inside up converter.............................................................................................15.4

  • 8/10/2019 Manual CMTS

    3/20

    CMTS basic commands ................................................................................................................17

    Commonly processing failure .....................................................................................................22.1

    CM unable to online....................................................................................................................22.2

    CM frequently missing...................................................................................................................23

    Common use indices......................................................................................................................23

    DHCP relay agency configuration...................................................................................................24

    . DHCP relay agency ...................................................................................................................24

    Setup CMTS network parameter and realize DHCP relay agent..............................................24

    Configure DHCP server ...........................................................................................................25

    1DHCP server installation..........................................................................................................25.2

    Configure the scope option...........................................................................................................25.3

    Deploy static router on DHCP server .......................................................................................33

    V

    DHCP relay agent function test .................................................................................................34

    The methods to control the quantity of the CM and to band the MAC address..............................35

    Operation step..........................................................................................................................35

    Create configuration files .........................................................................................................35

    1About configurefiles builder ....................................................................................................35.2

    Configuration file creation steps ...................................................................................................36.3

    Save configuration files .................................................................................................................40.4

    After saving the configuration files, put it in the directory that TFTP server appointed. .............40.5

    The advanced options configuration on DHCP server ..................................................................40.6

  • 8/10/2019 Manual CMTS

    4/20

    Summary......................................................................................................................................42

    Appendix 1 Configure the IP address to let the CMTS and the server in the same subnet .........44

    Appendix 2 Fix and configure TFTP server .....................................................................................48

    Copyright.2007

    Chongqing Jinghong High Tech Co., Ltd

    All rights reserved

    1

  • 8/10/2019 Manual CMTS

    5/20

    Copyright Declaration

    Chongqing Jinghong High-tech Co.,Ltd owns all the copyright of this manual. Without the

    permission of Jinghong, any organization or individual neither could reprint part nor complete

    content of this guide anyway. Chongqing Jinghong High-tech Co.,Ltd has the rights to modify thecontent, certainly not inform separately. The final explanation right of this guide belongs to

    Chongqing Jinghong High-tech Co.,Ltd.

    Chongqing Jinghong high-tech Co., Ltd copyright 2007

    Copyright.2007

    Chongqing Jinghong High Tech Co., Ltd

    All rights reserved

  • 8/10/2019 Manual CMTS

    6/20

    Foreword.

    The manual introduces wired and wireless environment based on DOCSIS agreement, how to

    install, configure and operate the CMTS. It can also guide users to find out and solve the problems.

    This manual is intended for broadband service providers and system administrators. Users of this

    manual must be familiar with items as following: Basic packet forwarding/switching protocols,

    including Ethernet bridging and TCP/IPl. Hybrid fiber/coax (HFC) cable networks for cable

    operators Fixed point-to-multipoint wireless transmission for wireless operators

    The guide primarily can be divided into three parts. The first part is the key point of this guide. It

    introduces the characteristic, fixing, configuration and common fault handing in detail with a lot of

    examples for analysis. The second part introduces how to construct CMTS IP network. The last part

    introduces the methods of controlling PC quantity under CM and how to bind MAC address of PC

    network card. In this guide, we try our best to bring forth new ideas. Provide users guidance with

    new added function & characteristic of JH-HE2086 CMTS and plenty of example analysis,.

    Packaging introduction

    Thanks for buying and using CMTS produced by Chongqing Jinghong High-tech Co.,Ltd. In order to

    make the equipments operate chronically and stably, please read this user manual carefully before

    start.

    Warning: During the process of operation, pull out thecoaxial-cable on the back panel is strictly

    forbidden. Otherwise, you should be responsible for the damages caused by yourself. Make sure

    the working voltage to be 220V 10%. CMTS full packaging listBefore you install the system,

    inspect all items in the package to ensure that they are undamaged in shipment. Check for physical

    damage to the chassis, and any loose or missing connectors. Any problems, please contact your

    service representative for help. No. 1 2 3 4 5 Content description JH-HE2086 CMTS 100Base-T

    twisted-pair Power cable User Manual CD Quantity 1 2 1 2 1

    Important files in the CD: No. 1 2 3 4 File name CFGEDIT.EXE CMTS user manual.pdf cm.cfg

    SETUP.EXE File location CD\Configuration file editor CD\User Manual CD\CM Configuration

    Document CD\Network Management Software CD\Network Management Software CD\Network

    Management Software CD\Network Management Software CD\Network Management SoftwareDescription Configuration file editor for CM CMTS basic configuration and user guide CM

    Configuration File CMTS network management software install program CMTS network

    management software install authorized number CMTS management network management

    software default system login account authorization files for network management software to

    manage CMTS

  • 8/10/2019 Manual CMTS

    7/20

    SN.TXT CMTS option parameter.txt login account.txt

    permit_number.txt

    network management software user manual.pdf

    CD\User Manual

    CMTS network management software operate guide

    NoteAny other content that has not been listed in the table mentioned above are not provided

    by Chongqing Jinghong high-tech Co., Ltd

    JH-HE 2086 CMTS Operation Guide.

    This chapter mainly describes the appearance characteristics, installation, configuration and how

    to deal with general breakdown of the JH-HE 2086 CMTS with examples.

    Summary

    1Brief Introduction Chongqing Jinghong High-tech Co., Ltd is a professional manufacturer of

    CMTS (Cable Modem Termination System) equipment in China. Since the first CMTS being

    produced in January 2000, we have launched several models of products in CMTS series. JH-HE

    2086 is a new generation of CMTS that we launched in March 2007. Based on its original model,

    this improved version has a bunch of remarkable new functions. The product is compliant with

    DOCSIS1.1 standard. It offers not only gateway services to HFC network and external network, but

    also broadband data and video transmission services that based on IP. It is especially suitable for

    the Cable TV operators and Multi-service operators (MSO) to offer stable and reliable broadband

    services for their Bidirectional HFC network users. JH-HE 2086 CMTS adopts 1U structure. It has

    integrated digital upconverter so that users can set proper downstream frequencies according to

    the network situation discretionarily. The equipment has four upstream channels and one

    downstream channel. JH-HE 2086 CMTS use QNX OSa distributed, embedded, real-time

    operation system similar to UNIX (in accord with POSIX) - as its operation system. 2Features

    Compatible with both EURO DOCSIS1.1 &US DOCSIS1.1it also compatible with DOCSIS2.0 cable

    modem. Support QoS. Available in both 1X1(1DS,1US) ,1 X 2(1DS,2US),&1X4(1DS,4US). Available

    for VOIP service.

    Customized design for cost sensitive operators Support up stream frequency automatic jumping to

    avoid disturbing frequency point. According to detecting upstream data error-code status, CMTS

    could estimate whether the current Working frequency points were disturbed or not .Once

    disturbed, the CMTS will jump frequency to spare frequency point to avoid frequency disturbing.You can set five frequency points each time. Support upstream modulate mode and baud rate

    automatic change to insure perfect balance of Upstream transmit efficiency and the ability to

    resist disturbance. Support DHCP relay agent and PPPoE dial-up. Bandwidth limit of both upstream

    and downstream. Bandwidth limit of upstream and downstream to single CM could avoid

    impropriating from BT downloading. Different kind of service as requested of various users offer

    convenient management to CATV operators. Both CM and CPE could choose layer-2,layer-3 even

  • 8/10/2019 Manual CMTS

    8/20

    mixed layer-2 & layer-3 working mode. It can be configured and operated by CLICOMSNMP.

    Log into CMTS by Telnet, configure and operate CMTS by command lines ,it is convenient for

    network administrator to manage and maintain both network and users as well as remote log in to

    upgrade all software. Optional internal high integrated DHCP/TFTP services mode. While this

    CMTS is used for household and hotel, such kind of small network scope, itcan realize most simple

    way broadband access by its highly integrated internal DHCP/TFTP server to reduce installation

    and operating cost. Integrated RF digital up-converter. It is easy to set RF frequency and power

    level by the function key on the panel. Adopt high performance CPU to improve data processing

    capability. Web management interface for convenient and cost effective operating. VFD and

    Minimized 1U platform designcost effectiveeasy to be piled and expanded. 3

    Index 3.1

    Downstream index:

    Modulation:64QAM / 256QAM

    Frequency range:88-860 MHz

    Output power level:105-118 dBVupconverter output power

    Symbol rate: 6.952 Msymps

    Data rate: 41 Mbps64QAM- 55 Mbps (256QAM)

    FEC: Reed-Solomon

    Channel bandwidth: 8 MHz

    Output impedance: 753.2

    Upstream index:

    Modulation modeQPSK / 16QAM

    Frequency range565 MHz

    Symbol rate: 320 640 640 1280 1280 2560 400 2560 5120 800 5120 Kbps(QPSK) 10240

    Kbps(16QAM) 1600 3200 KHz

    upstream bandwidth200

    Input power level160 ksymps 320 ksymps 640 ksymps 1280 ksymps 2560 ksymps

    FECReed-Solomon

    44~74dBuV 47~77 dBuV 50~80 dBuV 50~83 dBuV 56~86 dBuV

  • 8/10/2019 Manual CMTS

    9/20

    Input impedance75

    Transfer mediaCATV HFC network.

    Protocols compliant withDOCSIS, Euro-DOCSIS, TCP/IP, ARP, ICMP, SNMP, etc.

    3.3 Physical index

    RF Port5 RF connectors(metric)1 downstream, 4 upstreams ( F type).

    LAN Port2 duplex 100/10BaseT RJ45 connectors

    Status display: 8 LED separately display state of upstream channels, downstream channel, power

    supply, network interface.

    Outside portComKeyboardVGA

    Shape dimension: width: 43cm

    Net weight6Kg

    Power consumption60W

    Operation environment0~40Relative humidity

    telnet 192.168.0.200. After displaying login connection, the system display "login:" after entering

    "user name" then press

    Enter. Input password (attention differentiates capital and small letter), then press Enter. The

    screen appears "$" prompt symbol (if the user name is root ,the prompt symbol is #) to

    indicate entering the command mode.

    Note: User name and password for system administration are preserved in system resources CD

    "CMTS option parameter.ini" document. Please take care of them properly.

    4.2physical parameter configuration command4.2.1Upstream channel configuration

    parameter display sentencedisplay us

    Notedisplay upstream channel IDfrequencyon/off status and upstream modulation mode.

    4.2.2upstream frequency, modulation mode, channel switch setup sentencesetus Note

    Execute this command; there will be a menu mode user input access as follows: Cchoice channel

    Q) quit Optional input: c / C Enterinput channel ID1-4enter channel physical parameter

    then setup secondmenu as follows: M) Setup modulation mode R) Setup baud rate F) Setup

    channel frequency S) Setup channel switch P) Display current setting status Q) Quit & save

  • 8/10/2019 Manual CMTS

    10/20

    You can enter relative parameter setting by menu option

    Method

    parameter

    modulation

    symbol rate

    qpsk_2560k

    QPSK

    2560Ksym/sec

    qpsk_1280k

    QPSK

    1280Ksym/sec

    qpsk_640k

    QPSK

    640Ksym/sec

    qpsk_320k

    QPSK

    320Ksym/sec

    qpsk_160k

    QPSK

    160Ksym/sec

    q16d_2560k

  • 8/10/2019 Manual CMTS

    11/20

    16QAM

    2560Ksym/sec

    q16d_1280k

    16QAM

    1280Ksym/sec

    q16d_640k

    16QAM

    640Ksym/sec

    q16d_320k

    16QAM

    320Ksym/sec

    q16d_160k

    16QAM

    160Ksym/sec

    4.2.3Downstream channel configuration parameter display sentencedisplay ds

    Notedisplay downstream channel frequencymodulation mode and baud rate 4.2.4Setup

    downstream channel DOCSIS standard, modulation mode and baud rate sentencesetds Note

    Execute this command; there will be a menu mode user input access as follows:

    M) Setup modulation mode64QAM/256QAMS) Setup DOCSIS standardEUROA / USB

    P) Display current setting status Q) Quit & save 4.3TCP/IP configuration command4.3.1

    Setup CMTS network parameterincluding CMTS Ethernet accessCM subnetIP parameter of

    CPE subnetSentencesetnetwork NoteExecute this command and enter the first grade

    menu as follows: E) Setup Ethernet access parameter M) Setup CM subnet parameter CSetup

    CPE subnet parameter QQuit Choose menu and enter relative mode parameter second grade

  • 8/10/2019 Manual CMTS

    12/20

    menu, in this menu, you can setup IP add, subnet mask code, gateway IP add and access switch

    ,and so on.. As to CM,CPE subnet, you can also setup subnet working mode (layer-3 router /layer-2

    ) andnext station gateway parameter. 4.3.2Setup PPPOE protocol support Sentencepppoe

    ONorOFFNoteExecute this command according to parameter on/off switch PPPOE

    protocol support. 4.3.3Display CMTS TCP/IP configuration infoinclude CMTS IP addsubnet

    mask codegateway CM IP addsubnet mask codeCPE gateway IP addsubnet mask code

    external network gateway IP add and DHCP server IP addSentencedisplay net 4.4

    Control command to CM user:

    4.4.1Display online CM channel deployment and work status. Sentencedisplay cm 4.4.2

    Setup CM exchange visit control SentencecmevcalloworforbidNoteExecute this

    command, exchange visit control according to parameter allow/forbid. 4.5Other Command

    4.5.1CMTS restart Sentencecmtsreboot 4.5.2CMTS power off Sentencecmtsdown Note

    Run this command before you turn off the CMTS power supply. 4.5.3Display programs

    version number Sentenceshowvi 4.5.4Display system status SentencedisplayparameterParameterds us Display downstream channel parameter and work status Display upstream

    channel parameter and working status

    net Display network parameter cmevc pppoe Display exchange visit control function status Display

    PPPOE protocol support working status

    cm Display online CM channel distributing and working status NoteWhile inputfrequency

    parameterthe frequency value unit should be Hz As to different upstream channels

    connected to the same back-transfer cable ,the center frequency intervals should be 3.2 Hz

    After finishing all configuration, you must restart CMTS and then all those parameters you setup

    could be activated.

    4.6Operation command list Item 1 2 3 4 5 6 7 8 9 Command showvi cmtsdown cmtsreboot

    display setnetwork setds setus cmevc pppoe Function description Display programs version

    number CMTS power off CMTS restart Display CMTS sytem parameter CMTSCM gatewayCPE

    gatewaynext leap gateway and setup of DHCP server Downstream parameter setup upstream

    parameter setup CM exchange visit control setup Switch on/off PPPOE protocol support IP

    NotePlease pay special attention to letter capitalizations while inputting commands.

    Commonly processing failure

    1CM unable to online Cable Modem registered or not. Whether TFTPsimple file transfer

    protocolservice running on DHCP server or not and configured correctly. The matter of Cable

    Modem configuration files. Observe spectra through frequency spectrograph565MHz

    observe if there is constant noise jamming in upstream channel. Detect whether there is

  • 8/10/2019 Manual CMTS

    13/20

    downstream signal on cable through field-intensity meter or frequency spectrograph, and whether

    the downstream signal intensity is in the CM input level range. Whether the entry level of CMTS

    upstream channel is suitable. Visit the web of CM to view status, and lookup the malfunction.

    Change a Cable Modem. Notethe correlation technique indices, please refer to the ninth item

    in the common use indices. 2CM frequentlymissing. Observe spectra through frequency

    spectrograph565MHzobserve if there is gusty noise disturbing upstream channel. Circuit

    reason made the downstream channel Signal-to Noise RateSNRtoo low. Whether there is

    interference source around Cable Modem, such as radio emission antenna and so on. Change a

    Cable Modem.

    Common use indices

    Transmission level of Cable Modem68118dBVInput level of reversing amplifier>80

    dBVInput level of feedback optical transmitter7595 dBVThe input level of CMTS

    4486 dBVit is related to upstream transmission rateSuggest to configure it with60dBV. The input level of Cable Modem4575 dBVmaximum not exceeding 90dBV; The

    SNR of HFC network upstream is required not below 20 dB. DOCSIS protocol requires the indices

    not below 25dBthere is in favor of allowanceNotethe effective way to detect whether

    bidirectional HFC network fits for CMTS operation is: user transmits a signal that frequency range

    is 5-42or 65MHz 100 dBVyoud better use a signal produce instrument. If the

    incoming level of CMTS reaches 60 dBV it can satisfy the equipment operating requirement. The

    power level of every upstream signal that entering upstream mixer should be the same.

    DHCP relay agency configuration

    This part mainly introduces the conception of DHCP relay agency and its mode. It also presentedhow to configure and test DHCP server

    . DHCP relay agency

    The relay agent is a procedure that transfers DHCP / BOOTP info between client PC and server

    indifferent subnet. According to RFC, a standard documentation describes protocol design and

    relative operation, DHCP/BOOTP relay agent is a part of DHCP and BOOTP standard and function.

    DHCP relay agent transfer broadcasting mode DHCP/BOOTP info from one of its connected

    physical port (e.g. both upstream and downstream channels ) to other physical ports even other

    long-distance subnet. Jinghong CMTS DHCP relay agent function can transfer DHCP requests from

    network of CM, CPE and DHCP server then divided CM and CPE into different network section.

    Setup CMTS network parameter and realize DHCP relay agent

    In those network of CM and CPE (HFC plant), CMTS, as gateway, needs to configure gateway add.

    Of CPE and CM (please check network management software user manual for more details). The

    gateway adds Should be at the same network section as CPE and CM that worked under DHCP

    field but can not conflict with each other. In order to enable the DHCP requests could be sent to

  • 8/10/2019 Manual CMTS

    14/20

    correct DHCP server, you should setup DHCP server IP add on CMTS. (Please check NMS user

    manual 6.3 for more details) Suppose that an HFC plant IP programming is as follows: (all later

    parameters in this article should take this supposed parameter as the standard) 1CM IP add

    is172.16.4.0 / 22 2CPE IP add is172.16.8.0 / 22 3DHCP server and CMTS Ethernet network is

    172.168.0.0 / 24more details are as followsDHCP server IP add172.168.0.18 mask code

    255.255.255.0

    CMTS Ethernet port IP add172.168.0.200 mask code255.255.255.0 4Take CMTS RFaccess as

    gateway of CM and CPE, as followsCM gateway IP add172.16.4.1 mask code255.255.252.0

    the gateway of / 22CPE gateway IP add172.16.8.1 mask code255.255.252.0the

    gateway of network 172.16.8.0 / 22network 172.16.4.0

    Configure DHCP server

    Configuration of CMTS is just one of the part to realize DHCP relay agent , on the other side, you

    have to configure the DHCP server, the procedure is as follows: Confirm TFTP Server root defaul troute, click ok 1DHCP server installation The steps are of configuring and installation of DHCP.

    Configure DHCP server on windows2003, according to the following steps: 1.1On the control

    panel, double click Add or remove programs. 1.2In the dialog box Add or remove

    programs, click Add/remove windows component . 1.3In the page windows components

    Wizard, below subassembly, click network service, then click details. 1.4in the dialog box

    network service, in the network service subassembly, select Dynamic Host Configuration

    ProtocolDHCPcheck box, then click OK button. 2Configure the scope option After

    configuring DHCP server, we will set up scope. You can setup the scope follow the steps below. 2.1

    open DHCP from Administrative tools. 2.2In the DHCP manager, click add server option

    in the operation menu. It will pop a dialog box named as add server, in the this server blank ,

    input DHCP server IP address. Then click OK(chart 2-1).

    chart 2-1 2.3

    In the DHCP manager, click servers name with right button, and click newscope, in the dialog

    box new scope wizard, click Next . Input a scope name randomly. Then click Next(chart 2-2,

    chart 2-3).

    chart 2-2

    Chart 2-3 2.4The guide required us to define IP address range. Refer to the assumption in

    preceding context, we can set address segment from 172.168.0.10----172.168.0.230 and subnet

    mask is 255.255.252.0. Then click Next (chart 2-4).

    Chart 2-4 2.5 The guide will prompt you to add exclusions. Exclusions are addresses or a range of

  • 8/10/2019 Manual CMTS

    15/20

    addresses that are not distributed by the server. If there is no exclusion, click next to continue.

    chart 2-5.

    Chart 2-5 2.6The guide will prompt you input lease duration, default with 8 days. Select default

    or input lease duration you state.chart 2-6

    Chart 2-6 2.7The guide will prompt you to configure DHCP options. You may select no or yes.

    Here we select No. (chart 2-7)

    Chart 2-7 2.8Click Finish, the scope setup finished. 2.9After setup the scope, you need to

    configure scope option, 2.9.1 Scope optionRouter (this address is 172.168.0.1) Start-up server

    host name (TFTP server IP address). If TFTP server runs on DHCP server, the IP addresses of TFTP

    and DHCP servers are the same.

    DNS server

    e.g.: DNS server address is 61.128.128.68

    or 61.128.128.67

    Start-up file nameCM configuration file name.This file must locate in the directory that TFTP

    server appointed. 2.10If you want to configure these scope options, click scope options with

    right button.(chart 2-8)

    Chart 2-8 Select configure options to pop the dialog box Server Options. Select the options

    that you want to configure. You must configure the router option(chart 2-9), DNS server(chart 2-

    10), Boot server host name(chart 2-11), Bootfile Name(chart 2-12).

    Chart 2-9

    chart 2-10

    chart 2-11

    Chart 2-12 2.11After all the scopes have been configured, click apply, and finish. The

    options configured will appear in the DHCP manager scope option listchart 2-13

    Chart 2-13 2.12For the scope setup for DHCP is in inactive status, you should activate it so as to

    work normally. Right button click DHCP scope, then click activation in the pop-up menu.chart

    2-14.

    Chart 2-14 2.13When finish configuration, there will appear scope list. Show as following chart

    (chart 2-15).

  • 8/10/2019 Manual CMTS

    16/20

    Chart 2-15 2.1.4 The method of testing whether the DHCP server configured successfully, connect

    a PC to DHCP server to see whether it can acquire right IP address.Deploy static router on

    DHCP server If CM or CPE works at layer-3 router mode, the CMCPE & DHCP server will work at

    different network, therefore, the DHCP server will send info to CM/CPE, It must make sure that

    gateway sent to CM/CPE points to CMTS WAN access. See as following: 1CM IP add is172.16.4.0

    / 22 2CPE IP add is172.16.8.0 / 22 3DHCP server and CMTS Ethernet network is 172.168.0.0 /

    24more details are as followsDHCP server IP add172.168.0.18 mask code255.255.255.0

    CMTS Ethernet port IP add172.168.0.200 mask code255.255.255.0 4Take CMTS RF access

    as gateway of CM and CPE, as followsCM gateway IP add172.16.4.1 mask code

    255.255.252.0the gateway of network 172.16.4.0 / 22CPE gateway IP add172.16.8.1 mask

    code255.255.252.0the gateway of network 172.16.8.0 / 22Configuration of static router of

    DHCP server is as following: Purpose network172.16.4.0 mask code255.255.252.0 gateway

    172.168.0.200(cmts WAN access) Purpose network172.16.8.0 mask code255.255.252.0

    gateway172.168.0.200(cmts WAN access) NoteThe external network router related to CMTS

    must be setup to CPE network static router then the CPE could visit that external network.

    VDHCP relay agent function test

    Establish a simple network status, connect one CM at least. Pay attention to that whether the CM

    could got IP add of CM working field after distance measurement and whether it can download

    configuration files successfully after got the IP add. Once the CM got IP add and download

    configuration files and then registersuccessfully, connect at least one PC to CM, setup it into

    automatically got IP add mode. Detect whether the PC could got IP add in the CPE working field.

    All mentioned above successfully tested, it indicates that the DHCP relay agent works at a normal

    status.

    The methods to control the quantity of the CM and to band the MAC address

    Operation step

    1. Handtailor special configuration files for the CMs which need to limit the number of PC and tie

    the MAC to PC. 2. Put the configuration file to the list that the TFTP severs selected. 3. Hold an IP

    address for the CM in the action scope of DHCP servers. 4. Configure the action field in the

    reserved address. Change the configure files name in the option into the configure files name

    which the CM cunstom-builted. 5. After restart the CM, it will download the configure files. The

    files include the information about the number of PC and the MAC address. 6. Configuration goes

    into effect when the files download successfully. Connect a HUB with CM, and connect a PC with

    HUB. PC cant get rightIP address when the MAC addresses of PC net card and that set in the

    configuration files are different.

    Create configuration files

    1About configure files builder Configuration files editor is a professional tool software. It can

    create configuration files based on the necessary. For example, it can configure the PC quantity

    that connect with the CM (16 at most), configure the highest upstream rate(bit/s), tie the MAC

    address of the PC net card that connected with theCM. There are various kinds of configuration

  • 8/10/2019 Manual CMTS

    17/20

    file builder, e.g. TurboNet, 3COM and TBCwe suggest you use Turbonets config. File editor. Run

    cfgedit.exe, see chart 3-1:

    3-1

    2Configuration file create steps 2.1Clickinsert here..there is edit interfacesee3-23-

    3

    3-2

    3-3 See 3-3In the type window, You can make choice about downstream frequency point,

    upstream channel, network visit control and COS parameters, and so on. 2.2Choose Network

    Access in the picture above (this is a must-do option, the default result is pitch on, while the value

    is 1, it indicates that it allows terminal visiting network under CM), input 1 in the value space. 2.3

    Setup max number of PC under CM.Clickinsert here..see 3-3

    typecolumnsMaximum

    number in of CPEs,input quantity of PC in the valuecolumnsee3-4

    3-4 2.4Setup downstream & upstream parameter which including speed rate and burst out

    parameters. Firstly, choose Class of server Encodings, then choose Class IDMax. Upstream

    RateMax.downstream Rate, setup their max downstream & upstream speed rate, input

    speed rate value in value (unit: bps/s, while 0 indicates there is no speed limitation), see edit

    interface following:3-53-63-7unfolded as

    3-5

    3-6

    3-7 2.5Bind MAC add ofthe PC under CM. Click insert here..,choose CPE Ethernet MAC

    Addressin the type column of the unfolded edit interface, input MAC add of CPE in the value

    column.see3-8

    3-8

    NotePlease separate MAC adds by drop, if you want to bind several CPE, repeat those steps of

    2.5. 2.6CM configuration files creation finished. See3-9

    3-9 NoteThe quantity of bind MAC add should not be more than the quantity of PC under CM

    3Save configuration files After finishing all configuration files, click Save As ...in the file

    column, save the config. File as another file name. Our general operation is that name that file

  • 8/10/2019 Manual CMTS

    18/20

    name as the MAC add of CM , e.g.the MAC add is 00:02:5e:00:00:78, the config. Files name of

    the CM should be 00025e000078.cfg 4After saving the configuration files, put it in the

    directory that TFTP server appointed.

    The advanced options configuration on DHCP server

    Step 1: the reservation item in scope in DHCP, open new reservation dialog box, as the following

    chart showschart 3-10:

    Chart 3-10 Step 2: Input CM MAC address in MAC address blank.

    Step 3: Choose DHCP only in the sustaining type. Step 4: Click add. Step 5: Click the IP address

    in reservation list. Show as the following chartchart 3-11:

    Chart 3-11 Step 6:Right button click on this IP address. Show as the following chartchart 3-12:

    Chart 3-12 Step 7:Click configuration option to open the reservation option dialog box. And then

    select 067 Boot file Name item to input the CM custom-built configuration files name in the

    string value. For example 00025e000078.cfg. Show as the following chart(chart 3-13):

    Chart 3-13 Step 8:After configuration finished, there will be configuration file name provided for

    the CM in the configuration option list, Show as the following chart. (chart 3-14):

    Chart 3-14

    Summary

    In a word, if you want to control the PC quantity, and to tie up PC MAC address, you must

    customize a configuration file for the CM, in the file, besides several necessary options, it must

    includes maximum CPE quantity(Maximum No. of), CPE network card MAC address tied up. After

    configuration finished, you may give this file a name that easy to be recorded, youd better give it

    as the CM MAC address. Secondly, in the scope at DHCP server, set up reserved IP address, and

    reserved scope option for CM, the reserved scope option mainly is 067 Bootfile Name, you

    should fill in this item the custom-built configuration file name for the CM, after finished, restart

    the CM, the CM acquire this configuration file, the configuration will go into operation.

    Appendix 1

    Configure the IP address to let the CMTS and the server in the same subnet

    . CautionThe IP address of server must be in the same subnet as CMTS. The default IP

    address of JH-HE 2086 CMTS is172.168.0.200/24, use WAN port.

    Step 1:On the server, right button click my network places, select properties, open the window

  • 8/10/2019 Manual CMTS

    19/20

    like the following chart (chart 4-1).

    Chart 4-1 Step 2:Right button click Local Area Connections, select properties to open the

    window as the following(chart 4-2).

    Chart 4-2 Step 3: Select Internet ProtocolTCP/IPproperties to open the page as following

    clickchart 4-3. Input the IP address that in the same subnet with CMTS.

    Chart 4-3 Step 4: Click advanced button to open the window as following chartchart 4-4.

    Chart 4-4 Step 5: In the advanced TCP/IP dialog box, click add button to open the window as

    following chartchart 4-5.

    Chart 4-5 Step 6:Input 192.168.0.82 in the IP address blank, subnet mask255.255.255.0. Click

    add, then returnchart 4-6.

    Chart 4-6 Prompt: The additive IP address(192.168.0.82) is the IP address of network management

    port subnet.

    Notice: The configuration above is suitable for the situation that CMTS andsevers are in the same

    subnet. Step 7:Click OK, finish the configuration.

    Appendix 2

    Fix and configure TFTP server

    Step 1:Insert system resources CD provided by Jinghong corporation, find \CD\Assistant

    Software\3com tftp server file. Step 2:Open this file, and double click setup icon to preparing the

    install shield wizardchart 5-1.

    Chart 5-1 Step 3: In the installation interface, click next button. (chart 5 -2).

    Chart 5-2

    Step 4:Click Next button. Or click Browse to select installation path. Then click Next button.

    chart

    5-3

    Chart 5-3 Step 5: Click Next button to affirm the default program name, or input name you want

  • 8/10/2019 Manual CMTS

    20/20

    to use, then click Next buttonchart 5-4.

    Chart 5-4 Step 6:Click Finish button to finish the TFTP server installationchart 5-5.

    Chart 5-5 Step 7: Run TFTP software. Show as following chartchart 5-6: Click "View"and

    choose "Options"5-6

    Chart 5-6 Step 8: Confirm TFTP Server root default route, click ok Step 9: Copy JH.CFG file to

    appointed folder of TFTP Server rootdefault route. NoteCM.CFG file is located at a folder

    named CM configuration file in the CD offered by Jinghong company