Manning EC-F9-NH3 - MicroWatt Controls [Alberta, … EC-F9-NH3 sensor / transmitter The Manning...

2
Industry leading performance in ammonia detection technology Manning EC-F9-NH3 HWA6091 H_EC-F9-NH3_DS01017_V4.indd 1 11/25/2008 10:46:36 AM

Transcript of Manning EC-F9-NH3 - MicroWatt Controls [Alberta, … EC-F9-NH3 sensor / transmitter The Manning...

Page 1: Manning EC-F9-NH3 - MicroWatt Controls [Alberta, … EC-F9-NH3 sensor / transmitter The Manning EC-F9-NH3 with SensorCheck™ features industry-leading performance gas detection technology

Secondary headline

Industry leading performance in ammonia detection technology

Manning EC-F9-NH3

HWA6091 H_EC-F9-NH3_DS01017_V4.indd 1 11/25/2008 10:46:36 AM

Page 2: Manning EC-F9-NH3 - MicroWatt Controls [Alberta, … EC-F9-NH3 sensor / transmitter The Manning EC-F9-NH3 with SensorCheck™ features industry-leading performance gas detection technology

Man

ning

EC

-F9-

NH

3se

nso

r /

tran

smitt

er

The

Man

ning

EC

-F9-

NH

3 w

ith

Sen

sorC

heck

™ f

eatu

res

ind

ustr

y-le

adin

g

per

form

ance

gas

det

ecti

on

tech

nolo

gy

and

ad

ds

a b

uilt

-in

syst

em t

o m

oni

tor

and

p

red

ict

the

sens

or’s

ele

ctri

cal v

iab

ility

.

Amm

onia

Spe

cific

• Ra

pid

resp

onse

to a

mm

onia

• In

tern

al m

onito

ring

of 4

/20

mA

loop

circ

uitry

con

tinui

ty

Vers

atili

ty•

Can

be u

sed

with

any

Hon

eyw

ell A

nalyt

ics

read

out

• St

anda

rd ra

nge

of 1

00 p

pm c

an b

e re

scal

ed fo

r hig

her

rang

es•

Prov

ides

a li

near

out

put o

f 4/2

0 m

A as

a fu

nctio

n of

re

frige

rant

con

cent

ratio

n

Easy

Mai

nten

ance

• Qu

ick

and

easy

cal

ibra

tion

• Re

altim

e ca

libra

tion

elim

inat

es m

aint

enan

ce d

ownt

ime

Long

sen

sor

life

• Qu

ick

and

easy

cal

ibra

tion

ATM

OS™

Tec

hnol

ogy

• Al

low

s fo

r ope

ratio

n do

wn

to -

50 F

and

in c

onde

nsin

g hu

mid

ity e

nviro

nmen

ts o

r dur

ing

was

hdow

n•

Auto

mat

ical

ly ad

apts

to it

s en

viron

men

t and

pro

vides

ac

cura

te a

nd re

liabl

e pe

rform

ance

und

er th

e ha

rshe

st

cond

ition

s

Sens

orCh

eck™

Tec

hnol

ogy

• Ch

ecks

ope

ratin

g pa

ram

eter

s of

sen

sors

and

sen

ds a

no

tific

atio

n ou

tput

sig

nal i

f an

anom

aly

is id

entif

ied

• Te

sts

the

sens

or e

very

24

hour

s fo

r ele

ctric

al v

iabi

lity

• In

dica

tion

can

be d

etec

ted

by a

Man

ning

gas

mon

itor

or P

LC

Hous

ing

• NE

MA

1 #1

6 ga

uge

heav

y-du

ty s

teel

enc

losu

re•

Expl

osio

n-pr

oof d

esig

n av

aila

ble

Gen

eral

Des

crip

tion

The

Man

ning

EC

-F9-

NH

3 se

nsor

con

sist

s of

a

pair

of p

olar

ized

ele

ctro

des

isol

ated

from

the

ambi

ent a

ir by

a g

as p

erm

eabl

e m

embr

ane.

As

amm

onia

diff

uses

into

the

sens

or, a

redo

x re

actio

n oc

curs

, gen

erat

ing

a cu

rrent

line

arly

pro

porti

onal

to

am

mon

ia g

as c

once

ntra

tion.

Unl

ike

man

y ot

her

amm

onia

sen

sors

, thi

s ga

s di

ffusi

on d

etec

tor

exhi

bits

exc

elle

nt z

ero

and

calib

ratio

n st

abilit

y ov

er

long

per

iods

of t

ime.

EC

cel

ls o

ften

last

3-4

yea

rs

in th

e re

frige

rate

d en

viro

nmen

ts o

f foo

d pr

oces

sing

an

d st

orag

e w

areh

ouse

s. T

his

sens

or c

an p

rovi

de

dire

ct in

put i

nto

PLC

’s a

nd c

ompu

ter c

ontro

l sy

stem

s th

at a

ccep

t a li

near

4/2

0 m

A s

igna

l eith

er

dire

ctly

from

the

sens

or o

r fro

m a

ny M

anni

ng m

ulit-

chan

nel s

tand

alo

ne a

larm

con

sole

s w

ith re

lay

or

anal

og o

utpu

t.

Appl

icat

ions

•B

aker

ies

•B

ever

age,

Bot

tling

Pla

nts

•B

last

,Spi

ralF

reez

ers

•C

hem

ical

Man

ufac

turin

g•

Gas

Bot

tling

Pla

nts

•C

oole

rs•

Duc

t-M

ount

edS

enso

rs•

Equi

pmen

tRoo

ms

•Fo

odP

roce

ssin

g•

Frui

t,Ve

geta

ble

Pro

cess

ing

•Ic

eC

ream

Sto

rage

•Pe

ntho

uses

•Pe

rimet

erM

onito

ring

•Po

tabl

eW

ater

Pla

nts

•Po

ultr

y,M

eat,

Fish

Pro

cess

ing

•N

Ox

Red

uctio

n(p

ower

pla

nts)

•R

efrig

erat

ion

Sys

tem

s•

Sto

rage

Fre

ezer

s•

Turb

ine

Inle

tCoo

ling

•W

iner

ies

Avai

labl

ew

itha

nop

tiona

lLC

Dth

ata

llow

sre

alti

me

disp

lay

of g

as c

once

ntra

tion.

The

eas

y to

read

di

spla

yal

low

sfo

rqui

ckv

isua

lerro

reve

nts

upon

st

artu

p an

d tro

uble

shoo

ting

and

can

be c

alib

rate

d w

ithou

tav

oltm

eter

.The

EC

-F9-

NH

3w

ithL

CD

is

desi

gned

to w

ork

in th

e ha

rshe

st e

nviro

nmen

ts

incl

udin

g ch

emic

al w

ashd

own.

Tech

nica

l sum

mar

y

Gene

ral S

peci

ficat

ion

Use

El

ectro

chem

ical

(diff

usio

n) ty

pe s

enso

r tha

t wor

ks in

con

junc

tion

with

any

Hon

eyw

ell A

nalyt

ics

read

out o

r ala

rm u

nit.

Read

outs

ha

ve b

uilt

in v

isua

l and

aud

ible

ala

rms,

as

wel

l as

rela

y ou

tput

for v

entil

atio

n fa

n ac

tivat

ion,

cen

tral a

larm

tie-

in, e

tc. T

he

Man

ning

EC-

F9-N

H3 c

an p

rovid

e a

linea

r 4/2

0 m

A si

gnal

inpu

t int

o PL

C’s.

Com

mon

Ope

ratio

n

Oper

atio

n In

uni

ts w

ithou

t the

opt

iona

l LCD

mod

ule,

a g

roup

of L

ED’s

are

inst

alle

d to

the

PCB.

In u

nits

with

the

optio

nal L

CD, t

wo

exte

rnal

pu

sh b

utto

ns, “

Acce

pt”

and

“Scr

oll”

are

used

to n

avig

ate

test

func

tions

and

ope

ratin

g m

odes

.

LCD

disp

lay

(opt

iona

l) 2

line

by 8

alp

ha n

umer

ic c

hara

cter

s an

d co

ntin

uous

bac

klig

ht

Outp

ut

Isol

ated

4/2

0 m

A, 7

00 o

hms

max

. at 2

4 VD

C. S

igna

l out

put r

educ

es to

0.5

mA

to in

dica

te a

faul

t con

ditio

n. R

S-48

5, M

odbu

s

RTU

prot

ocol

Accu

racy

+

/- 5

% g

ener

ally,

but

lim

ited

by a

vaila

ble

calib

ratio

n ga

s ac

cura

cy. E

nclo

sure

con

tain

s no

mov

ing

parts

, con

tribu

ting

to a

ccu

racy

leve

ls.

Envi

ronm

enta

l IP

ratin

g In

door

use

, IP

44 in

acc

orda

nce

with

EN6

0529

:199

2

Oper

atio

nal

Hum

idity

5-

100%

RH

(con

dens

ing)

Tem

pera

ture

-4

5°C

to +

49°C

/ -5

0°F

to +

120°

F, AT

MOS

equ

ippe

d en

viro-

adap

tive

tech

nolo

gy re

quire

d fo

r ref

riger

ated

are

as o

r out

door

s

Sens

or P

ress

ure

Lim

it 0-

10 P

SIG

Stor

age

-40°

C to

+80

°C /

-40°

F to

+17

6°F,

20 to

80%

RH (n

on c

onde

nsin

g)

Com

mon

Mod

ule

Com

mun

icat

ion

4/20

mA

outp

ut: #

18/3

shi

elde

d ca

ble

(Bel

den

8770

or e

qual

), ca

ble

runs

< 1

,500

ft. R

S-48

5: fo

r com

mun

icat

ion

cabl

e, u

se

24 A

WG

twis

ted

pair,

shi

elde

d (B

elde

n #9

841

or e

qual

), ca

ble

runs

up

to 2

,000

ft. F

or p

ower

cab

le u

se 1

4 AW

G (B

elde

n

#510

0UE

or e

qual

), ca

ble

runs

up

to 1

,000

feet

.

Pow

er S

ourc

e 24

VDC

, 0.5

am

p m

ax.

Repe

atab

ility

+

/- 2

% fu

ll sc

ale

Sens

or S

peci

ficat

ions

Sens

or P

ress

ure

Lim

its 0

-10

PSIG

Resp

onse

Tim

e T5

0 =

10

seco

nds

T100

< 1

sec

ond

for c

once

ntra

tion

> 1

% N

H3

Rang

es

0-10

0 pp

m (s

tand

ard)

0-25

0 pp

m0-

500

ppm

0-10

00 p

pm

Sens

or V

iabi

lity

Test

Se

nsor

Chec

k, a

n in

tern

al m

icro

proc

esso

r det

erm

ines

the

sens

or’s

ele

ctric

al v

iabi

lity

ever

y 24

hou

rs. I

f the

via

bilit

y te

st fa

ils, a

n

0.5

mA

sign

al w

ill id

icat

e a

faul

t. An

inte

rnal

ligh

t will

show

if a

sen

sor i

s dr

ied

up o

r dis

conn

ecte

d.

Encl

osur

e NE

MA

1, g

aske

ted,

#16

gau

ge s

teel

(sta

ndar

d). S

tain

less

ste

el o

r exp

losi

on-p

roof

des

igns

, inc

ludi

ng m

odifi

ed e

nclo

sure

s fo

r lo

w te

mpe

ratu

res,

ven

tilat

ion

duct

s, e

tc. a

re a

vaila

ble.

Wei

ght

3 lb

s.

EC-F

9-NH

3 w

ith L

CD o

ptio

n

HW

A60

91 H

_EC

-F9-

NH

3_D

S010

17_V

4.in

dd

2-3

11/2

5/20

08

10:4

6:44

AM