Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North...

12
Mandible Modular Fixation System. Comprehensive implant system for mandible trauma and reconstruction. Locking and reconstruction plates Trauma and microvascular plates IMF screw set

Transcript of Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North...

Page 1: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Mandible Modular Fixation System.Comprehensive implant system formandible trauma and reconstruction.

Locking and reconstructionplates

Trauma andmicrovascularplates

IMF screw set

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 3

Page 2: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

3 Synthes Mandible Modular Fixation System

The Synthes Mandible Fixation System provides a comprehensive plating system for mandibular trauma and reconstruction. The system includes numerous instrument options, and features the following plating choices:

2.0 mm Mandible Locking Plates (MLP)– A locking and nonlocking advanced plating system

for trauma, microvascular reconstruction and orthognathic surgery

– A variety of plates in four thicknesses and locked or nonlocked, self-drilling or self-tapping screws with StarDrive or PlusDrive recess

Locking Reconstruction Plates (LRP)– Choice of 2.4 mm or 3.0 mm screws

– A locking and nonlocking system for the option of locked or standard screw-and-plate fixation to achieve stability

– Indicated for trauma or reconstruction applications

Mandible Modular Fixation System

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 4

Page 3: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Synthes 2

2.4 mm Mandible Trauma Plates– Indicated for the fixation of mandibular fractures

– Features LC-DCP and universal fracture plates

2.4 mm Microvascular Plates– Low-profile, limited-contact plates for mandible

reconstruction

– For use in conjunction with a vascularized bone graft

IMF Screw Set– 2.0 mm screws with cruciform recess

– For temporary perioperative use in stabilizing the occlusion

– For simple, nondisplaced, adult mandibular andmaxillary fractures and orthognathic procedures

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 5

Page 4: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

2.0 mm Mandible Locking Plate Module

Provides locked or nonlocked, self-drilling or self-tapping, 2.0 mm screw-and-plate fixation.

Indications– Trauma– Reconstructive surgery– Orthognathic surgery

Features– Single implant system addresses a broad range of indications

– Low-profile plating system minimizes implant palpability

– Made of commercially pure (CP) titanium for biocompatibility

3 Synthes Mandible Modular Fixation System

Locking screws (with PlusDrive and StarDrive recess)– Available in self-drilling and self-tapping designs

– Special double-lead threads in screw head engage and lock in threaded plate holes, eliminating a need for two-piece locking screws

– One size screw (2.0 mm) fits all 2.0 mm mandible locking plates (MLP)

– Made of high-strength titanium alloy*

– Locking screws are color-coded blue for ease of identification (nonlocking self-tapping are gold, self-drilling are silver)

– PlusDrive recess improves retention with screwdriver blade, reduces stripping and cam-out and provides off-axis screw placement ability

Self-drilling tip

StarDrive recessPlusDrive recess

Cortex Locking

Self-drillingcortex

Emergency

Self-tapping tip

0.75 mmpitch

Conical double-lead locking threads

* Ti-6AI-7Nb

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 6

Page 5: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Synthes 4

Mandible locking plates– Four profiles accommodate a wide range of indications

– A variety of straight, angled and curved styles

– Hole spacing designed to optimize fixation in reconstructive surgery

– Design facilitates rapid three-dimensional contouring for improved anatomic fit

– Threaded plate hole accepts both nonlocking and locking 2.0 mm PlusDrive and StarDrive screws

– Mini plates for simple trauma; intermediate, large and extra plates for less stable trauma and microvascular reconstruction applications

1.0Mini

1.3Intermediate

1.5Large

2.0Extra

4.8

5.0

6.5

6.5

Locking design– Increases construct stability

– Decreases risk of screw back-out and subsequent loss of reduction

– Reduces the need for precise anatomic plate contouring

– Minimizes the risk of stripped screw holes

– Provides a positive stop for locking screws, especially when using the Synthes Battery Powered Screwdriver

– Preserves reduction intraoperatively by maintaining plate-to-bone position

Extra*(2.0 mm thick)

447.304

447.310

447.101

447.315

447.210

447.103 447.118

447.102

447.424

Large*(1.5 mm thick)

Intermediate*(1.3 mm thick)

Mini*(1.0 mm thick)

447.412

*Additional plates available in each thickness.

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 7

Page 6: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Locking Reconstruction Plate Module

Provides the option of locked or nonlocked screw and plate fixation to achieve stability

Indications– Trauma– Reconstruction*

Features– Choice of 2.4 mm or 3.0 mm locking, or 2.4 mm

nonlocking screws

– Low-profile plate-and-screw construct

– Commercially pure titanium for biocompatibility and MRI safety

*Plate fracture is possible when any plate bears the entire functionalload for extended periods. Therefore, the implantation of bone graft immediately or at a later date is necessary to support the construct. (See also Prein J. ed. (1998) Manual of Internal Fixation in the Cranio-Facial Skeleton.)

3 Synthes Mandible Modular Fixation System

Locking screws (with cruciform recess)– Special double-lead thread in the screw head engages

and locks in the threaded holes of the plate

– The locking feature eliminates the need for expansion screws

– Color-coding assists in locking screw size identification

2.4 mm (nonlocking)cortex screw

3.0 mmlocking screw

2.4 mm locking screw

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 8

Page 7: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Synthes 6

Locking reconstruction plates– Plate hole design offers both locking and nonlocking

options for trauma and reconstruction

– Selection includes various sizes of straight, angled,double-angled and condylar head plates

– Threaded plate hole accepts both 2.4 mm and 3.0 mmlocking screws for optimal fixation

– Reconstruction plate with condylar head available*

Important: The titanium locking reconstruction plate withcondylar head is not intended for use as a permanentprosthetic device, for patients with temporomandibularjoint disorders (TMD), or patients with traumatic injuries tothe temporomandibular joint (TMJ).

* Titanium Locking Reconstruction Plate, with condylar head, 5 x 20 holes, right (449.648)

2.4 mm Titanium Locking Reconstruction Plate, with angle, 6 x 23 holes, right (449.633)

2.4 mm Titanium Locking Reconstruction Plate, 20 holes (449.621)

2.4 mm Titanium Locking Reconstruction Plate, with double angle, 5 x 22 x 5 holes (449.637)

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 9

Page 8: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

2.4 mm Mandible Trauma Module

Indications– Mandible trauma

– Reconstruction

Features– Mandible trauma plates available in straight, angled

or crescent shapes

– LC-DCP and universal fracture plates used in conjunctionwith a tension band plate to rigidly fix the fracture

– Longer length 2.4 mm screws, in pop-up rack, for lagscrew fixation

– Made of commercially pure (CP) titanium for biocompatibility

3 Synthes Mandible Modular Fixation System

TensionBand

Universal Fracture

Lag Screws

2.4 mm Titanium Compression Tension Band Plate, 6 holes(449.110)

2.4 mm Titanium LC-DCP Plate, 5 holes (449.15)

2.4 mm Titanium Universal FracturePlate, 8 holes (449.38)

2.4 mm Titanium Universal FracturePlate, with angle, 4 x 4 holes(449.84)

2.4 mm Titanium Crescent LC-DCPPlate, 6 holes (449.26)

25438-J5303D_25438-J5303D 9/13/10 7:20 AM Page 10

Page 9: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

2.4 mm Microvascular Module

Indications– For mandible reconstruction

Features– Single, continuous plate is flush, yet provides proper

projection of the mandible

– Limited plate-to-bone contact improves vascularity beneath plate

– Low plate-screw profile reduces palpability and is more easily contoured

– Notched plate design aids in three-dimensional contouring

– Made of commercially pure (CP) titanium for biocompatibility

Synthes 8

2.4 mm Titanium Microvascular Plate, with angle, 6 x 18 holes, right (449.446)

2.4 mm Titanium Microvascular Plate, with double angle, 5 x 22 x 5 holes (449.451)

2.4 mm Titanium Microvascular Plate, 12 holes (449.412)

25438-J5303D_25438-J5303D 9/13/10 7:20 AM Page 11

Page 10: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

IMF Screw Set

For temporary, perioperative use in stabilizing the occlusionin simple, adult mandibular and maxillary fractures and orthognathic procedures

– Not intended for long-term stabilization or definitive management of facial fractures

Indications– Indirect stabilization of the maxilla and mandible following

craniofacial and mandibular trauma or reconstruction

Contraindications– Severely comminuted and/or displaced fractures

– Unstable, segmented maxillary or mandibular arches

– Combined maxillary and mandibular fractures

– Pediatric injuries

Implant features– 2.0 mm screws, available in 8 mm and 12 mm

thread lengths

– Made of extra-hard 316L stainless steel for maximum strength

– Self-drilling and self-tapping for easy, one-step insertion

– Groove under screw head secures wires or elastics

– Cruciform recess works with existing Synthesinstrumentation

– Two cross holes in the screw align with the cruciform head slots, simplifying wire passage

System features– Simplified intermaxillary fixation technique when

compared to arch bars

– Reduces application time

– Minimizes the potential risk of wire punctures

– Can easily be applied or removed in the OR, ER or office setting

Patient comfort benefits– Minimal hardware

– Reduced soft tissue trauma

– Improved postoperative oral hygiene

3 Synthes Mandible Modular Fixation System

25438-J5303D_25438-J5303D 9/13/10 7:20 AM Page 12

Page 11: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Mandible Modular Fixation System

Graphic case options– 3-high (one instrument level and

two implant levels, holds up to 4 insert trays)

– 4-high (two instrument levels and two implant levels, holds up to 8 insert trays)

– 4-high, long (two instrument levels and two implant levels, holds up to 12 insert trays)

– Customized instrument and implant options

Note: For additional information onthe instruments, implants, cases, andinsert trays for this system, please refer to the Synthes Mandible Instrumentand Set Information brochure.

Synthes 10

25438-J5303D_25438-J5303D 9/13/10 7:20 AM Page 13

Page 12: Mandible Modular Fixation System TGsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North Americ… · or crescent shapes – LC-DCP and universal fracture plates used in conjunction

Synthes CMF1302 Wrights Lane EastWest Chester, PA 19380Telephone: (610) 719-5000To order: (800) 523-0322Fax: (610) 251-9056

Synthes (Canada) Ltd.2566 Meadowpine BoulevardMississauga, Ontario L5N 6P9Telephone: (905) 567-0440To order: (800) 668-1119Fax: (905) 567-3185

© 2004 Synthes, Inc. or its affiliates. All rights reserved. LC-DCP, PlusDrive and Synthes are trademarks of Synthes, Inc. or its affiliates. Printed in U.S.A. 8/10 J5303-D

www.synthes.com

25438-J5303D_25438-J5303D 9/13/10 7:19 AM Page 2