Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5- ACD - G 3/4, G 1 - lockable - for padlocks - with pressure gauge - suitable for ATEX Version 2-in-1, Can be assembled into blocks Parts Filter pressure regulator, Lubricator Mounting orientation vertical Certificates suitable for ATEX Working pressure min./max. See table below Ambient temperature min./max. 14 ... 122 °F Medium temperature min./max. 14 ... 122 °F Medium Compressed air, Neutral gases Nominal flow Qn 12.5 Cv Regulator type Diaphragm-type pressure regulator Regulator function with relieving air exhaust Adjustment range min./max. 8 ... 116 psi Pressure supply single Filter reservoir volume 2.94 fl.oz. Filter element exchangeable Condensate drain See table below Lubricator reservoir volume 6.12 fl.oz. Type of filling Semi-automatic oil filling during operation, Manual oil filling Weight See table below Technical data Part No. Port Flow Working pressure min./max. Condensate drain Qn R412009298 G 3/4 12.5 Cv 22 ... 232 psi semi-automatic, open without pressure R412009299 G 3/4 12.5 Cv 22 ... 232 psi fully automatic, open without pressure R412009300 G 3/4 12.5 Cv 0 ... 232 psi fully automatic, closed without pressure R412009307 G 1 12.5 Cv 22 ... 232 psi semi-automatic, open without pressure R412009308 G 1 12.5 Cv 22 ... 232 psi fully automatic, open without pressure R412009309 G 1 12.5 Cv 0 ... 232 psi fully automatic, closed without pressure Part No. Weight R412009298 4.03 lbs R412009299 4.14 lbs R412009300 4.14 lbs R412009307 4.03 lbs R412009308 4.14 lbs R412009309 4.14 lbs PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Transcript of Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series...

Page 1: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 1 | AVENTICS

Maintenance unit, 2-part, Series AS5-ACD- G 3/4, G 1- lockable- for padlocks- with pressure gauge- suitable for ATEX

Version 2-in-1, Can be assembled into blocksParts Filter pressure regulator, LubricatorMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesNominal flow Qn 12.5 CvRegulator type Diaphragm-type pressure regulatorRegulator function with relieving air exhaustAdjustment range min./max. 8 ... 116 psiPressure supply singleFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowLubricator reservoir volume 6.12 fl.oz.Type of filling Semi-automatic oil filling during operation,

Manual oil fillingWeight See table below

Technical data

Part No. Port Flow Working pressure min./max. Condensate drainQn

R412009298 G 3/4 12.5 Cv 22 ... 232 psi semi-automatic, open without pressureR412009299 G 3/4 12.5 Cv 22 ... 232 psi fully automatic, open without pressureR412009300 G 3/4 12.5 Cv 0 ... 232 psi fully automatic, closed without pressureR412009307 G 1 12.5 Cv 22 ... 232 psi semi-automatic, open without pressureR412009308 G 1 12.5 Cv 22 ... 232 psi fully automatic, open without pressureR412009309 G 1 12.5 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Weight

R412009298 4.03 lbsR412009299 4.14 lbsR412009300 4.14 lbsR412009307 4.03 lbsR412009308 4.14 lbsR412009309 4.14 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 2: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 2 | AVENTICS

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Compressed air class 6 : 7 : -

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate

Protective guard Polyamide

Filter insert Polyethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 3: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 3 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connectionA7 = condensate drain1) Plastic reservoir and protective guard with window2) Semi-automatic condensate drain3) Fully automatic condensate drain4) Port for semi-automatic oil filling5) Mounting option for padlocks, max. shackle Ø 8

DimensionsDimensions in mm

A1 A2 A3 A7 A8 B C D E1 E2 G H1 H2 H3 L1 L2 M T7 V W

G 3/4 G 3/4 G 1/4 G 1/8 G 1/8 170 103 109 75 30.5 M50x1,5 250 266 239 41 60 58 8.5 38 63G 1 G 1 G 1/4 G 1/8 G 1/8 170 103 109 75 30.5 M50x1,5 250 266 239 41 60 58 8.5 38 63

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 4: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 4 | AVENTICS

Diagrams

Lubricator activation margin

p1 = working pressureqn = nominal flow

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 5: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 5 | AVENTICS

Maintenance unit, 3-part, Series AS5-ACT- G 3/4, G 1- lockable- for padlocks- with pressure gauge- suitable for ATEX

Version 3-part, Can be assembled into blocksParts Pressure regulator, Filter, LubricatorMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesNominal flow Qn 12.5 CvRegulator type Diaphragm-type pressure regulatorRegulator function with relieving air exhaustAdjustment range min./max. 8 ... 116 psiPressure supply singleFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowLubricator reservoir volume 6.12 fl.oz.Type of filling Semi-automatic oil filling during operation,

Manual oil fillingWeight See table below

Technical data

Part No. Port Flow Working pressure min./max. Condensate drainQn

R412009320 G 3/4 12.5 Cv 0 ... 232 psi fully automatic, closed without pressureR412009318 G 3/4 12.5 Cv 22 ... 232 psi semi-automatic, open without pressureR412009319 G 3/4 12.5 Cv 22 ... 232 psi fully automatic, open without pressureR412009329 G 1 12.5 Cv 0 ... 232 psi fully automatic, closed without pressureR412009327 G 1 12.5 Cv 22 ... 232 psi semi-automatic, open without pressureR412009328 G 1 12.5 Cv 22 ... 232 psi fully automatic, open without pressure

Part No. Weight

R412009320 5.9 lbsR412009318 5.79 lbsR412009319 5.9 lbsR412009329 5.9 lbsR412009327 5.79 lbsR412009328 5.9 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 6: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 6 | AVENTICS

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Compressed air class 6 : 7 : -

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate

Protective guard Polyamide

Filter insert Polyethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 7: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 7 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connectionA7 = condensate drain1) Plastic reservoir and protective guard with window2) Semi-automatic condensate drain3) Fully automatic condensate drain4) Port for semi-automatic oil filling5) Mounting option for padlocks, max. shackle Ø 8

DimensionsDimensions in mm

A1 A2 A3 A7 A8 B C D E1 E2 G H1 H2 H3 L1 L2 M T7 V W

G 3/4 G 3/4 G 1/4 G 1/8 G 1/8 255 103 109 75 30.5 M50x1,5 250 266 239 41 60 58 8.5 38 63G 1 G 1 G 1/4 G 1/8 G 1/8 255 103 109 75 30.5 M50x1,5 250 266 239 41 60 58 8.5 38 63

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 8: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 8 | AVENTICS

Diagrams

Lubricator activation margin

p1 = working pressureqn = nominal flow

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 9: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 9 | AVENTICS

Pressure regulator, Series AS5-RGS- G 3/4, G 1- Qn = 14.74 Cv- Standard pressure regulator- Activation Mechanical- lockable- for padlocks- suitable for ATEX

Parts Pressure regulatorMounting orientation AnyCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesRegulator type Diaphragm-type pressure regulator, Can

be assembled into blocksRegulator function with relieving air exhaustAdjustment range min./max. See table belowLock type for padlocksPressure supply singleActivation MechanicalInternal air consumption q,max. 0 CvWeight See table below

Technical data

Part No. Port Flow Working pressure min./max. Adjustment rangemin./max.

WeightQn

R412009101 G 3/4 14.74 Cv 2 ... 232 psi 2 ... 14 psi 2.2 lbsR412009103 G 3/4 14.74 Cv 2 ... 232 psi 2 ... 29 psi 2.2 lbsR412009105 G 3/4 14.74 Cv 3 ... 232 psi 3 ... 58 psi 2.2 lbsR412009107 G 3/4 14.74 Cv 8 ... 232 psi 8 ... 116 psi 2.2 lbsR412009109 G 3/4 14.74 Cv 8 ... 232 psi 8 ... 145 psi 2.2 lbsR412009111 G 3/4 14.74 Cv 8 ... 232 psi 8 ... 232 psi 2.2 lbsR412009100 G 3/4 14.74 Cv 2 ... 232 psi 2 ... 14 psi 2 lbsR412009102 G 3/4 14.74 Cv 2 ... 232 psi 2 ... 29 psi 2 lbsR412009104 G 3/4 14.74 Cv 3 ... 232 psi 3 ... 58 psi 2 lbsR412009106 G 3/4 14.74 Cv 8 ... 232 psi 8 ... 116 psi 2 lbsR412009108 G 3/4 14.74 Cv 8 ... 232 psi 8 ... 145 psi 2 lbsR412009110 G 3/4 14.74 Cv 8 ... 232 psi 8 ... 232 psi 2 lbsR412009113 G 1 14.74 Cv 2 ... 232 psi 2 ... 14 psi 2.2 lbsR412009115 G 1 14.74 Cv 2 ... 232 psi 2 ... 29 psi 2.2 lbsR412009117 G 1 14.74 Cv 3 ... 232 psi 3 ... 58 psi 2.2 lbsR412009119 G 1 14.74 Cv 8 ... 232 psi 8 ... 116 psi 2.2 lbsR412009121 G 1 14.74 Cv 8 ... 232 psi 8 ... 145 psi 2.2 lbsR412009123 G 1 14.74 Cv 8 ... 232 psi 8 ... 232 psi 2.2 lbsR412009112 G 1 14.74 Cv 2 ... 232 psi 2 ... 14 psi 2 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 10: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 10 | AVENTICS

Part No. Port Flow Working pressure min./max. Adjustment rangemin./max.

WeightQn

R412009114 G 1 14.74 Cv 2 ... 232 psi 2 ... 29 psi 2 lbsR412009116 G 1 14.74 Cv 3 ... 232 psi 3 ... 58 psi 2 lbsR412009118 G 1 14.74 Cv 8 ... 232 psi 8 ... 116 psi 2 lbsR412009120 G 1 14.74 Cv 8 ... 232 psi 8 ... 145 psi 2 lbsR412009122 G 1 14.74 Cv 8 ... 232 psi 8 ... 232 psi 2 lbs

Part No.

R412009101 1)R412009103 1)R412009105 1)R412009107 1)R412009109 1)R412009111 1)R412009100 2)R412009102 2)R412009104 2)R412009106 2)R412009108 2)R412009110 2)R412009113 1)R412009115 1)R412009117 1)R412009119 1)R412009121 1)R412009123 1)R412009112 2)R412009114 2)R412009116 2)R412009118 2)R412009120 2)R412009122 2)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi1) Pressure gauge enclosed separately, Suitable for use in Ex zones 1, 2, 21, 222) Order pressure gauge separately, Suitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .The rear pressure gauge connection on the pressure regulator is closed with a blanking plug, the front connection is open. Dependingon the customer application, a second blanking plug may be necessary. Please order separately (see accessories).Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Relieving exhaust (≤ 4.35 psi over set pressure)With rear exhaust (> 43.5 psi )

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 11: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 11 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connection1) Mounting option for padlocks, max. shackle Ø 8

DimensionsDimensions in mm

A1 A2 A3 B C D E1 F G L1 L2 M V W

G 3/4 G 3/4 G 1/4 85 103 109 75 112 M50x1,5 41 60 58 38 63G 1 G 1 G 1/4 85 103 109 75 112 M50x1,5 41 60 58 38 63

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 12: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 12 | AVENTICS

Diagrams

Pressure characteristics curve

p1 = working pressurep2 = secondary pressureqn = nominal flow* starting point

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = working pressurep2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 13: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 13 | AVENTICS

Pressure regulator, Series AS5-RGS-...-E11- G 1- Qn = 14.74 Cv- Standard pressure regulator- Activation Mechanical- lockable- with E11 locking

Parts Pressure regulatorMounting orientation AnyWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesRegulator type Diaphragm-type pressure regulator, Can

be assembled into blocksRegulator function with relieving air exhaustAdjustment range min./max. See table belowLock type with E11 lockingPressure supply singleActivation MechanicalInternal air consumption q,max. 0 CvWeight 2 lbs

Technical data

Part No. Port Flow Working pressure min./max. Adjustment range min./max.Qn

R412009099 G 1 14.74 Cv 8 ... 232 psi 8 ... 145 psiR412009158 G 1 14.74 Cv 3 ... 232 psi 3 ... 58 psi

Order pressure gauge separately, Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .The E11 locking is delivered without a key (see accessories for keys).The rear pressure gauge connection on the pressure regulator is closed with a blanking plug, the front connection is open. Dependingon the customer application, a second blanking plug may be necessary. Please order separately (see accessories).A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Relieving exhaust (≤ 4.35 psi over set pressure)With rear exhaust (> 43.5 psi )

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 14: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 14 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connection1) Order pressure gauge separately

DimensionsDimensions in mm

A1 A2 A3 B C D E1 F M

G 1 G 1 G 1/4 85 103 109 90 112 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 15: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 15 | AVENTICS

Diagrams

Pressure characteristics curve

p1 = working pressurep2 = secondary pressureqn = nominal flow* starting point

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = working pressurep2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 16: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 16 | AVENTICS

Pressure regulator, Series AS5-RGS- G 3/4, G 1- Qn = 16.77 Cv- Standard pressure regulator- Activation Pneumatically

Parts Pressure regulatorMounting orientation AnyWorking pressure min./max. 8 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesRegulator type Diaphragm-type pressure regulator, Can

be assembled into blocksRegulator function with relieving air exhaustAdjustment range min./max. 8 ... 232 psiPressure supply singleActivation PneumaticallyWeight 2.37 lbs

Technical data

Part No. Port FlowQn

R412009094 G 3/4 16.77 CvR412009095 G 1 16.77 Cv

Control pressure: see diagram, Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiOrder pressure gauge separately

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .The rear pressure gauge connection on the pressure regulator is closed with a blanking plug, the front connection is open. Dependingon the customer application, a second blanking plug may be necessary. Please order separately (see accessories).A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Relieving exhaust (≤ 4.35 psi over set pressure)With rear exhaust (> 43.5 psi )

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 17: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 17 | AVENTICS

Material

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connectionA4 = control pressure connection1) Order pressure gauge separately

DimensionsDimensions in mm

A1 A2 A3 A4 B C D E F

G 3/4 G 3/4 G 1/4 G 1/4 85 103 109 32.6 145G 1 G 1 G 1/4 G 1/4 85 103 109 32.6 145

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 18: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 18 | AVENTICS

Diagrams

Pressure characteristics curve

p1 = working pressurep2 = secondary pressureqn = nominal flow1) = Starting point

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = working pressurep2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 19: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 19 | AVENTICS

Diagramscontrol pressure characteristic

p1 = working pressurep2 = secondary pressurePS = control pressure

Circuit diagram

Application example

1) precision pressure regulator2) pressure regulator valve, pneumatically operated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 20: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 20 | AVENTICS

Filter pressure regulator, Series AS5-FRE- G 3/4, G 1- lockable- for padlocks- suitable for ATEX

Version 1-in-1, Can be assembled into blocksParts Filter pressure regulatorMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesNominal flow Qn 14.23 CvRegulator type Diaphragm-type pressure regulatorRegulator function with relieving air exhaustAdjustment range min./max. See table belowPressure supply singleFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowMax. Internal air consumption 0 CvWeight See table below

Technical data

Part No. Port Flow Working pressure min./max. Adjustment range min./max.Qn

R412009200 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009201 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009202 G 3/4 14.23 Cv 0 ... 232 psi 8 ... 116 psiR412009206 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009207 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009208 G 3/4 14.23 Cv 0 ... 232 psi 8 ... 145 psiR412009175 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009176 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009177 G 3/4 14.23 Cv 0 ... 232 psi 8 ... 116 psiR412009193 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009194 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009195 G 3/4 14.23 Cv 0 ... 232 psi 8 ... 145 psiR412009181 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009182 G 3/4 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009183 G 3/4 14.23 Cv 0 ... 232 psi 8 ... 116 psiR412009209 G 1 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009210 G 1 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009211 G 1 14.23 Cv 0 ... 232 psi 8 ... 116 psiR412009215 G 1 14.23 Cv 22 ... 232 psi 8 ... 145 psi

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 21: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 21 | AVENTICS

Part No. Port Flow Working pressure min./max. Adjustment range min./max.Qn

R412009216 G 1 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009217 G 1 14.23 Cv 0 ... 232 psi 8 ... 145 psiR412009184 G 1 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009185 G 1 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009186 G 1 14.23 Cv 0 ... 232 psi 8 ... 116 psiR412009190 G 1 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009191 G 1 14.23 Cv 22 ... 232 psi 8 ... 116 psiR412009192 G 1 14.23 Cv 0 ... 232 psi 8 ... 116 psiR412009196 G 1 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009197 G 1 14.23 Cv 22 ... 232 psi 8 ... 145 psiR412009198 G 1 14.23 Cv 0 ... 232 psi 8 ... 145 psi

Part No. Condensate drain Reservoir Protective guard Weight

R412009200 semi-automatic, open without pressure Polycarbonate Polyamide 2.39 lbs 1)R412009201 fully automatic, open without pressure Polycarbonate Polyamide 2.5 lbs 1)R412009202 fully automatic, closed without pressure Polycarbonate Polyamide 2.5 lbs 1)R412009206 semi-automatic, open without pressure Die cast zinc - 3.46 lbs 1)R412009207 fully automatic, open without pressure Die cast zinc - 3.57 lbs 1)R412009208 fully automatic, closed without pressure Die cast zinc - 3.57 lbs 1)R412009175 semi-automatic, open without pressure Polycarbonate Polyamide 2.18 lbs 2)R412009176 fully automatic, open without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009177 fully automatic, closed without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009193 semi-automatic, open without pressure Polycarbonate Polyamide 2.18 lbs 2)R412009194 fully automatic, open without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009195 fully automatic, closed without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009181 semi-automatic, open without pressure Die cast zinc - 3.26 lbs 2)R412009182 fully automatic, open without pressure Die cast zinc - 3.37 lbs 2)R412009183 fully automatic, closed without pressure Die cast zinc - 3.37 lbs 2)R412009209 semi-automatic, open without pressure Polycarbonate Polyamide 2.39 lbs 1)R412009210 fully automatic, open without pressure Polycarbonate Polyamide 2.5 lbs 1)R412009211 fully automatic, closed without pressure Polycarbonate Polyamide 2.5 lbs 1)R412009215 semi-automatic, open without pressure Die cast zinc - 3.46 lbs 1)R412009216 fully automatic, open without pressure Die cast zinc - 3.57 lbs 1)R412009217 fully automatic, closed without pressure Die cast zinc - 3.57 lbs 1)R412009184 semi-automatic, open without pressure Polycarbonate Polyamide 2.18 lbs 2)R412009185 fully automatic, open without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009186 fully automatic, closed without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009190 semi-automatic, open without pressure Die cast zinc - 3.26 lbs 2)R412009191 fully automatic, open without pressure Die cast zinc - 3.37 lbs 2)R412009192 fully automatic, closed without pressure Die cast zinc - 3.37 lbs 2)R412009196 semi-automatic, open without pressure Polycarbonate Polyamide 2.18 lbs 2)R412009197 fully automatic, open without pressure Polycarbonate Polyamide 2.29 lbs 2)R412009198 fully automatic, closed without pressure Polycarbonate Polyamide 2.29 lbs 2)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi1) Pressure gauge enclosed separately, Suitable for use in Ex zones 1, 2, 21, 222) Order pressure gauge separately, Suitable for use in Ex zones 1, 2, 21, 22

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 22: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 22 | AVENTICS

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Compressed air class 6 : 7 : -

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Filter insert Polyethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 23: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 23 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connectionA7 = condensate drain1) Plastic reservoir and protective guard with window2) Metal reservoir with level indicator3) Semi-automatic condensate drain4) Fully automatic condensate drain5) Mounting option for padlocks, max. shackle Ø 8

DimensionsDimensions in mm

A1 A2 A3 A7 B C D E1 G H1 H2 H3 H4 L1 L2 M T7 V W

G 3/4 G 3/4 G 1/4 G 1/8 85 103 109 75 M50x1,5 250 206 193.5 210.5 41 60 58 8.5 38 63G 1 G 1 G 1/4 G 1/8 85 103 109 75 M50x1,5 250 206 193.5 210.5 41 60 58 8.5 38 63

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 24: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 24 | AVENTICS

Diagrams

Pressure characteristics curve

p1 = working pressurep2 = secondary pressureqn = nominal flow* starting point

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = working pressurep2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 25: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 25 | AVENTICS

Filter pressure regulator, Series AS5-FRE- G 3/4, G 1- lockable- for padlocks- suitable for ATEX

Version 1-in-1, Can be assembled into blocksParts Filter pressure regulatorMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. 22 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesNominal flow Qn 13.21 CvRegulator type Diaphragm-type pressure regulatorRegulator function with relieving air exhaustAdjustment range min./max. 8 ... 116 psiPressure supply singleFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain semi-automatic, open without pressureMax. Internal air consumption 0 CvWeight 3.46 lbs

Technical data

Part No. Port Flow Condensate drainQn

R412009188 G 3/4 13.21 Cv semi-automatic, open without pressureR412009189 G 1 13.21 Cv semi-automatic, open without pressure

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiOrder pressure gauge separately, Suitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Compressed air class 7 : 7 : -

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 26: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 26 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Die cast zinc

Protective guard Polyamide

Filter insert Polyethylene

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connection1) Metal reservoir with level indicator2) Semi-automatic condensate drain3) Mounting option for padlocks, max. shackle Ø 8

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 27: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 27 | AVENTICS

DimensionsDimensions in mm

A1 A2 A3 B C D E1 G H1 L1 L2 M V W

G 3/4 G 3/4 G 1/4 85 103 109 75 M50x1,5 250 41 60 58 38 63G 1 G 1 G 1/4 85 103 109 75 M50x1,5 250 41 60 58 38 63

Diagrams

Pressure characteristics curve

p1 = working pressurep2 = secondary pressureqn = nominal flow* starting point

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = working pressurep2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 28: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 28 | AVENTICS

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 29: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 29 | AVENTICS

Filter pressure regulator, Series AS5-FRE- G 3/4, G 1- lockable- for padlocks- suitable for ATEX

Version 1-in-1, Can be assembled into blocksParts Filter pressure regulatorMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesNominal flow Qn 14.23 CvRegulator type Diaphragm-type pressure regulatorRegulator function with relieving air exhaustAdjustment range min./max. 8 ... 145 psiPressure supply singleFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowMax. Internal air consumption 0 CvWeight See table below

Technical data

Part No. Port Flow Working pressure min./max. Condensate drainQn

R412009218 G 3/4 14.23 Cv 22 ... 232 psi semi-automatic, open without pressureR412009219 G 3/4 14.23 Cv 22 ... 232 psi fully automatic, open without pressureR412009220 G 3/4 14.23 Cv 0 ... 232 psi fully automatic, closed without pressureR412009221 G 1 14.23 Cv 22 ... 232 psi semi-automatic, open without pressureR412009222 G 1 14.23 Cv 22 ... 232 psi fully automatic, open without pressureR412009223 G 1 14.23 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Weight

R412009218 2.18 lbsR412009219 2.29 lbsR412009220 2.29 lbsR412009221 2.18 lbsR412009222 2.29 lbsR412009223 2.29 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiOrder pressure gauge separately, Suitable for use in Ex zones 1, 2, 21, 22

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 30: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 30 | AVENTICS

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Compressed air class 7 : 7 : -

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate

Protective guard Polyamide

Filter insert Polyethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 31: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 31 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA3 = pressure gauge connectionA7 = condensate drain1) Plastic reservoir and protective guard with window2) Semi-automatic condensate drain3) Fully automatic condensate drain4) Mounting option for padlocks, max. shackle Ø 8

DimensionsDimensions in mm

A1 A2 A3 A7 B C D E1 G H1 H2 L1 L2 M T7 V W

G 3/4 G 3/4 G 1/4 G 1/8 85 103 109 75 M50x1,5 250 266 41 60 58 8.5 38 63G 1 G 1 G 1/4 G 1/8 85 103 109 75 M50x1,5 250 266 41 60 58 8.5 38 63

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 32: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 32 | AVENTICS

Diagrams

Pressure characteristics curve

p1 = working pressurep2 = secondary pressureqn = nominal flow* starting point

DiagramsFlow rate characteristic (setting range p2: 0.5 - 8 bar)

p1 = working pressurep2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 33: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 33 | AVENTICS

Filter, Series AS5-FLS- G 3/4, G 1- suitable for ATEX

Version Standard filter, Can be assembled intoblocks

Parts FilterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowWeight See table below

Technical data

Part No. Port Qn Working pressure min./max. Condensate drain

R412009000 G 3/4 7.93 Cv 22 ... 232 psi semi-automatic, open without pressureR412009001 G 3/4 7.93 Cv 22 ... 232 psi fully automatic, open without pressureR412009002 G 3/4 7.93 Cv 0 ... 232 psi fully automatic, closed without pressureR412009006 G 3/4 7.93 Cv 22 ... 232 psi semi-automatic, open without pressureR412009007 G 3/4 7.93 Cv 22 ... 232 psi fully automatic, open without pressureR412009008 G 3/4 7.93 Cv 0 ... 232 psi fully automatic, closed without pressureR412009009 G 1 7.93 Cv 22 ... 232 psi semi-automatic, open without pressureR412009010 G 1 7.93 Cv 22 ... 232 psi fully automatic, open without pressureR412009011 G 1 7.93 Cv 0 ... 232 psi fully automatic, closed without pressureR412009015 G 1 7.93 Cv 22 ... 232 psi semi-automatic, open without pressureR412009016 G 1 7.93 Cv 22 ... 232 psi fully automatic, open without pressureR412009017 G 1 7.93 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Reservoir Protective guard Weight

R412009000 Polycarbonate Polyamide 1.58 lbsR412009001 Polycarbonate Polyamide 1.7 lbsR412009002 Polycarbonate Polyamide 1.7 lbsR412009006 Die cast zinc, with window - 2.67 lbsR412009007 Die cast zinc, with window - 2.78 lbsR412009008 Die cast zinc, with window - 2.78 lbsR412009009 Polycarbonate Polyamide 1.58 lbsR412009010 Polycarbonate Polyamide 1.7 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 34: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 34 | AVENTICS

Part No. Reservoir Protective guard Weight

R412009011 Polycarbonate Polyamide 1.7 lbsR412009015 Die cast zinc, with window - 2.67 lbsR412009016 Die cast zinc, with window - 2.78 lbsR412009017 Die cast zinc, with window - 2.78 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Max. achievable compressed air class acc. to ISO 8573-1:2010 6 : 7 : -

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Filter insert Polyethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 35: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 35 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA7 = condensate drain1) Plastic reservoir and protective guard with window2) Metal reservoir with level indicator3) Semi-automatic condensate drain4) Fully automatic condensate drain

DimensionsDimensions in mm

A1 A2 A7 B C D H1 H2 H3 H4 M T7

G 3/4 G 3/4 G 1/8 85 103 109 250 266 254 270.5 58 8.5G 1 G 1 G 1/8 85 103 109 250 266 254 270.5 58 8.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 36: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 36 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 37: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 37 | AVENTICS

Filter, Series AS5-FLS- G 3/4, G 1- suitable for ATEX

Version Standard filter, Can be assembled intoblocks

Parts FilterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. 22 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain semi-automatic, open without pressureWeight See table below

Technical data

Part No. Port Qn Weight

R412009089 G 3/4 7.93 Cv 2.67 lbsR412009090 G 1 7.93 Cv 2.78 lbs

Nominal flow with secondary pressure 91.35 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Max. achievable compressed air class acc. to ISO 8573-1:2010 7 : 7 : -

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 38: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 38 | AVENTICS

Material

Threaded bushing Die cast zinc

Reservoir Die cast zinc

Filter insert Polyethylene

Dimensions

Dimensions

A1 = inputA2 = output1) Metal reservoir with level indicator2) Semi-automatic condensate drain

DimensionsDimensions in mm

A1 A2 B C D H1 M

G 3/4 G 3/4 85 103 109 250 58G 1 G 1 85 103 109 250 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 39: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 39 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 40: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 40 | AVENTICS

Filter, Series AS5-FLS- G 3/4, G 1- suitable for ATEX

Version Standard filter, Can be assembled intoblocks

Parts FilterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowWeight See table below

Technical data

Part No. Port Qn Working pressure min./max. Condensate drain

R412009003 G 3/4 7.93 Cv 22 ... 232 psi semi-automatic, open without pressureR412009004 G 3/4 7.93 Cv 22 ... 232 psi fully automatic, open without pressureR412009005 G 3/4 7.93 Cv 0 ... 232 psi fully automatic, closed without pressureR412009012 G 1 7.93 Cv 22 ... 232 psi semi-automatic, open without pressureR412009013 G 1 7.93 Cv 22 ... 232 psi fully automatic, open without pressureR412009014 G 1 7.93 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Weight

R412009003 1.58 lbsR412009004 1.7 lbsR412009005 1.7 lbsR412009012 1.58 lbsR412009013 1.7 lbsR412009014 1.7 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 41: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 41 | AVENTICS

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Max. achievable compressed air class acc. to ISO 8573-1:2010 7 : 7 : -

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate

Protective guard Polyamide

Filter insert Sintered bronze

Dimensions

Dimensions

A1 = inputA2 = output

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 42: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 42 | AVENTICS

A7 = condensate drain1) Plastic reservoir and protective guard with window2) Metal reservoir with level indicator3) Semi-automatic condensate drain4) Fully automatic condensate drain

DimensionsDimensions in mm

A1 A2 A7 B C D H1 H2 H3 H4 M T7

G 3/4 G 3/4 G 1/8 85 103 109 250 266 254 270.5 58 8.5G 1 G 1 G 1/8 85 103 109 250 266 254 270.5 58 8.5

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 43: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 43 | AVENTICS

Pre-filter, Series AS5-FLP- G 3/4, G 1- suitable for ATEX

Version Pre-filter, Can be assembled into blocksParts Pre-filterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowWeight See table below

Technical data

Part No. Port Qn Working pressure min./max. Condensate drain

R412009018 G 3/4 2.24 Cv 22 ... 232 psi semi-automatic, open without pressureR412009019 G 3/4 2.24 Cv 22 ... 232 psi fully automatic, open without pressureR412009020 G 3/4 2.24 Cv 0 ... 232 psi fully automatic, closed without pressureR412009024 G 3/4 2.24 Cv 22 ... 232 psi semi-automatic, open without pressureR412009025 G 3/4 2.24 Cv 22 ... 232 psi fully automatic, open without pressureR412009026 G 3/4 2.24 Cv 0 ... 232 psi fully automatic, closed without pressureR412009027 G 1 2.24 Cv 22 ... 232 psi semi-automatic, open without pressureR412009028 G 1 2.24 Cv 22 ... 232 psi fully automatic, open without pressureR412009029 G 1 2.24 Cv 0 ... 232 psi fully automatic, closed without pressureR412009033 G 1 2.24 Cv 22 ... 232 psi semi-automatic, open without pressureR412009034 G 1 2.24 Cv 22 ... 232 psi fully automatic, open without pressureR412009035 G 1 2.24 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Reservoir Protective guard Weight

R412009018 Polycarbonate Polyamide 1.57 lbsR412009019 Polycarbonate Polyamide 1.68 lbsR412009020 Polycarbonate Polyamide 1.68 lbsR412009024 Die cast zinc - 2.67 lbsR412009025 Die cast zinc - 2.78 lbsR412009026 Die cast zinc - 2.78 lbsR412009027 Polycarbonate Polyamide 1.57 lbsR412009028 Polycarbonate Polyamide 1.68 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 44: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 44 | AVENTICS

Part No. Reservoir Protective guard Weight

R412009029 Polycarbonate Polyamide 1.68 lbsR412009033 Die cast zinc - 2.67 lbsR412009034 Die cast zinc - 2.78 lbsR412009035 Die cast zinc - 2.78 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 1.45 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Recommended pre-filtering 5 µm

Max. achievable compressed air class acc. to ISO 8573-1:2010 2 : - : 3

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Filter insert Impregnated paper

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 45: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 45 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA7 = condensate drain1) Plastic reservoir and protective guard with window2) Metal reservoir with inspection glass3) Semi-automatic condensate drain4) Fully automatic condensate drain

DimensionsDimensions in mm

A1 A2 A7 B C D E1 H1 H2 H3 H4 M T7

G 3/4 G 3/4 G 1/8 85 103 109 5 250 266 254 270.5 58 8.5G 1 G 1 G 1/8 85 103 109 5 250 266 254 270.5 58 8.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 46: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 46 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 47: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 47 | AVENTICS

Pre-filter, Series AS5-FLP- G 3/4, G 1- contamination display integrated- suitable for ATEX

Version Pre-filter, Can be assembled into blocksParts Pre-filterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowcontamination display integratedWeight See table below

Technical data

Part No. Port Qn Working pressure min./max. Condensate drain

R412009021 G 3/4 2.24 Cv 22 ... 232 psi semi-automatic, open without pressureR412009022 G 3/4 2.24 Cv 22 ... 232 psi fully automatic, open without pressureR412009023 G 3/4 2.24 Cv 0 ... 232 psi fully automatic, closed without pressureR412009030 G 1 2.24 Cv 22 ... 232 psi semi-automatic, open without pressureR412009031 G 1 2.24 Cv 22 ... 232 psi fully automatic, open without pressureR412009032 G 1 2.24 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Weight

R412009021 0.796 lbsR412009022 0.904 lbsR412009023 0.904 lbsR412009030 0.796 lbsR412009031 0.904 lbsR412009032 1.68 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 1.45 psiSuitable for use in Ex zones 1, 2, 21, 22

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 48: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 48 | AVENTICS

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Recommended pre-filtering 5 µm

Max. achievable compressed air class acc. to ISO 8573-1:2010 2 : - : 3

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate

Protective guard Polyamide

Filter insert Impregnated paper

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 49: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 49 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA7 = condensate drain1) Plastic reservoir and protective guard with window2) Semi-automatic condensate drain3) Fully automatic condensate drain4) contamination display

DimensionsDimensions in mm

A1 A2 A7 B C D E1 H1 H2 M T7

G 3/4 G 3/4 G 1/8 85 103 109 23.7 250 266 58 8.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 50: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 50 | AVENTICS

A1 A2 A7 B C D E1 H1 H2 M T7

G 1 G 1 G 1/8 85 103 109 23.7 250 266 58 8.5

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 51: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 51 | AVENTICS

Microfilter, Series AS5-FLC- G 3/4, G 1- suitable for ATEX

Version Microfilter, Can be assembled into blocksParts MicrofilterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowWeight See table below

Technical data

Part No. Port Qn Working pressure min./max. Condensate drain

R412009036 G 3/4 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009037 G 3/4 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009038 G 3/4 1.63 Cv 0 ... 232 psi fully automatic, closed without pressureR412009042 G 3/4 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009043 G 3/4 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009044 G 3/4 1.63 Cv 0 ... 232 psi fully automatic, closed without pressureR412009045 G 1 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009046 G 1 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009047 G 1 1.63 Cv 0 ... 232 psi fully automatic, closed without pressureR412009051 G 1 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009052 G 1 1.63 Cv 22 ... 232 psi fully automatic, closed without pressureR412009053 G 1 1.63 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Reservoir Protective guard Weight

R412009036 Polycarbonate Polyamide 1.57 lbs 1)R412009037 Polycarbonate Polyamide 1.68 lbs 1)R412009038 Polycarbonate Polyamide 1.68 lbs 1)R412009042 Die cast zinc - 2.67 lbs 2)R412009043 Die cast zinc - 2.78 lbs 2)R412009044 Die cast zinc - 2.78 lbs 2)R412009045 Polycarbonate Polyamide 1.57 lbs 1)R412009046 Polycarbonate Polyamide 1.68 lbs 1)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 52: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 52 | AVENTICS

Part No. Reservoir Protective guard Weight

R412009047 Polycarbonate Polyamide 1.68 lbs 1)R412009051 Die cast zinc - 2.67 lbs 2)R412009052 Die cast zinc - 2.78 lbs 2)R412009053 Die cast zinc - 2.78 lbs 2)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 1.45 psi1) Suitable for use in Ex zones 1, 2, 21, 222) Reservoir with level indicator, Suitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Recommended pre-filtering 0.3 µm

Max. achievable compressed air class acc. to ISO 8573-1:2010 1 : - : 2

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Filter insert Borosilicate glass fiber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 53: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 53 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA7 = condensate drain1) Plastic reservoir and protective guard with window2) Metal reservoir with inspection glass3) Semi-automatic condensate drain4) Fully automatic condensate drain

DimensionsDimensions in mm

A1 A2 A7 B C D E1 H1 H2 H3 H4 M T7

G 3/4 G 3/4 G 1/8 85 103 109 5 250 266 254 270 58 8.5G 1 G 1 G 1/8 85 103 109 5 250 266 254 270 58 8.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 54: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 54 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 55: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 55 | AVENTICS

Microfilter, Series AS5-FLC- G 3/4, G 1- contamination display integrated- suitable for ATEX

Version Microfilter, Can be assembled into blocksParts MicrofilterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain See table belowcontamination display integratedWeight See table below

Technical data

Part No. Port Qn Working pressure min./max. Condensate drain

R412009054 G 3/4 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009060 G 3/4 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009055 G 3/4 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009056 G 3/4 1.63 Cv 0 ... 232 psi fully automatic, closed without pressureR412009061 G 3/4 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009062 G 3/4 1.63 Cv 0 ... 232 psi fully automatic, closed without pressureR412009063 G 1 1.63 Cv 22 ... 232 psi semi-automatic, open without pressureR412009069 G 1 1.63 Cv 0 ... 232 psi semi-automatic, open without pressureR412009064 G 1 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009065 G 1 1.63 Cv 0 ... 232 psi fully automatic, closed without pressureR412009070 G 1 1.63 Cv 22 ... 232 psi fully automatic, open without pressureR412009071 G 1 1.63 Cv 0 ... 232 psi fully automatic, closed without pressure

Part No. Reservoir Protective guard Weight

R412009054 Polycarbonate Polyamide 0.796 lbsR412009060 Die cast zinc, with window - 3.41 lbsR412009055 Polycarbonate Polyamide 0.904 lbsR412009056 Polycarbonate Polyamide 0.904 lbsR412009061 Die cast zinc, with window - 3.47 lbsR412009062 Die cast zinc, with window - 3.46 lbsR412009063 Polycarbonate Polyamide 0.796 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 56: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 56 | AVENTICS

Part No. Reservoir Protective guard Weight

R412009069 Die cast zinc, with window - 3.26 lbsR412009064 Polycarbonate Polyamide 0.904 lbsR412009065 Polycarbonate Polyamide 1.68 lbsR412009070 Die cast zinc, with window - 3.32 lbsR412009071 Die cast zinc, with window - 3.31 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 1.45 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.Also suitable for separation of fluid oil or water due to the design.

Recommended pre-filtering 0.3 µm

Max. achievable compressed air class acc. to ISO 8573-1:2010 1 : - : 2

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Filter insert Borosilicate glass fiber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 57: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 57 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA7 = condensate drain1) Plastic reservoir and protective guard with window2) Metal reservoir with level indicator3) Semi-automatic condensate drain4) Fully automatic condensate drain5) contamination display

DimensionsDimensions in mm

A1 A2 A7 B C D E1 H1 H2 M T7

G 3/4 G 3/4 G 1/8 85 103 109 23.7 250 -- 58 8.5G 3/4 G 3/4 -- 85 103 109 23.7 -- 266 58 --G 1 G 1 G 1/8 85 103 109 23.7 250 -- 58 8.5G 1 G 1 -- 85 103 109 23.7 -- 266 58 --

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 58: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 58 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 59: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 59 | AVENTICS

Active carbon filter, Series AS5-FLA- G 3/4, G 1- suitable for ATEX

Version Active carbon filter, Can be assembledinto blocks

Parts Active carbon filterMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. 0 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesFilter reservoir volume 2.94 fl.oz.Filter element exchangeableCondensate drain withoutWeight See table below

Technical data

Part No. Port Qn Reservoir Protective guard Weight

R412009072 G 3/4 1.73 Cv Polycarbonate Polyamide 1.57 lbsR412009074 G 3/4 1.73 Cv Die cast zinc, with window - 0.827 lbsR412009075 G 1 1.73 Cv Polycarbonate Polyamide 1.57 lbsR412009077 G 1 1.73 Cv Die cast zinc, with window - 0.827 lbs

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 1.45 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Recommended pre-filtering 0.01 µm

Max. achievable compressed air class acc. to ISO 8573-1:2010 - : - : 1

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 60: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 60 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Filter insert Active carbon

Dimensions

Dimensions

A1 = inputA2 = output1) Plastic reservoir and protective guard with window2) Metal reservoir with inspection glass

DimensionsDimensions in mm

A1 A2 B C D H1 H2 M

G 3/4 G 3/4 85 103 109 242 246 58G 1 G 1 85 103 109 242 246 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 61: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 61 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 62: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 62 | AVENTICS

Standard oil-mist lubricator, SeriesAS5-LBS- G 3/4, G 1- suitable for ATEX

Version Oil-mist lubricator, Can be assembled intoblocks

Parts Standard oil-mist lubricatorMounting orientation verticalCertificates suitable for ATEXWorking pressure min./max. 8 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesLubricator reservoir volume 6.12 fl.oz.Type of filling Semi-automatic oil filling during operation,

Manual oil fillingWeight See table below

Technical data

Part No. Port Nominal flow Qn Reservoir Protective guard Weight

R412009225 G 3/4 16.06 Cv Polycarbonate Polyamide 1.68 lbs 1)R412009229 G 3/4 16.06 Cv Die cast zinc, with window - 1.68 lbs 1)R412009226 G 3/4 16.06 Cv Polycarbonate Polyamide 1.7 lbs 2)R412009231 G 1 16.06 Cv Polycarbonate Polyamide 1.68 lbs 1)R412009235 G 1 16.06 Cv Die cast zinc, with window - 1.68 lbs 1)R412009232 G 1 16.06 Cv Polycarbonate Polyamide 1.7 lbs 2)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi1) Suitable for use in Ex zones 1, 2, 21, 222) Suitable for use in Ex zones 1, 2, 21, 22, Electrical level detection

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Electrical level detection only with ST6 sensor with reed contact, sensor holder included in the scope of the delivery.Sensor not included in scope of delivery, sensor installation prepared.The entire preset drip quantity enters the pressure systemManual oil filling possible during operation at a maximum operating pressure of 10 bar.Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at "Customer information".Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Oil dosing at 1 Cv 1-2 drops

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 63: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 63 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Dimensions

Dimensions

A1 = inputA2 = output1) Plastic reservoir and protective guard with window2) Metal reservoir with inspection glass3) Holder for sensor4) Port for semi-automatic oil filling

DimensionsDimensions in mm

A1 A2 A7 A8 B C D E1 H1 H2 M T7

G 3/4 G 3/4 G 1/8 G 1/4 85 103 109 30.5 239 243 58 8.5G 1 G 1 G 1/8 G 1/4 85 103 109 30.5 239 243 58 8.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 64: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 64 | AVENTICS

Diagrams

Lubricator activation margin

p1 = working pressureqn = nominal flow

DiagramsFlow rate characteristic

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 65: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 65 | AVENTICS

Filling unit, electrically operated,Series AS5-SSU- Compressed air connection G 3/4, G 1- Pipe connection- ATEX optional

Version Poppet valve, Can be assembled intoblocks

Parts Filling valve, 3/2-directional valve,electrically operated

Nominal flow 8.89 CvNominal flow 1 ▶ 2 8.89 CvNominal flow 2 ▶ 3 3.76 CvWorking pressure min./max. 37 ... 145 psiMedium Compressed air, Neutral gasesMedium temperature min./max. 14 ... 122 °FAmbient temperature min./max. 14 ... 122 °FPilot InternalSealing principle Soft sealingMax. particle size 25 µmProtection class acc. to DIN EN61140,with plug

IP65

Protection class acc. to DIN EN61140,Without valve plug connector

See table below

Duty cycle 100 %Weight See table below

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 66: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 66 | AVENTICS

Technical data

Part No. Compressed air connection input Compressed air connection output Exhaust

R412009277 G 3/4 G 3/4 G 1/2R412009286 G 3/4 G 3/4 G 1/2R412009282 G 1 G 1 G 1/2R412009287 G 1 G 1 G 1/2R412009278 G 3/4 G 3/4 G 1/2R412009279 G 3/4 G 3/4 G 1/2R412009280 G 3/4 G 3/4 G 1/2R412009378 G 1 G 1 G 1/2R412009283 G 1 G 1 G 1/2R412009284 G 1 G 1 G 1/2R412009285 G 1 G 1 G 1/2

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 HzR412009277 - - -R412009286 - - -R412009282 - - -R412009287 - - -R412009278 24 V - -R412009279 - 110 V 110 VR412009280 - 220 V 230 VR412009378 24 V - -R412009283 24 V - -R412009284 - 110 V 110 VR412009285 - 220 V 230 V

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

R412009277 - - - -R412009286 - - - -R412009282 - - - -R412009287 - - - -R412009278 2 W - - -R412009279 - 1.6 VA 1.4 VA 2.2 VAR412009280 - 1.6 VA 1.4 VA 2.2 VAR412009378 2 W - - -R412009283 2 W - - -R412009284 - 1.6 VA 1.4 VA 2.2 VAR412009285 - 1.6 VA 1.4 VA 2.2 VA

Part No. Switch-on power Electrical connection Connector standardAC 60 Hz Pilot valve

R412009277 - - -R412009286 - - -R412009282 - - -R412009287 - - -

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 67: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 67 | AVENTICS

Part No. Switch-on power Electrical connection Connector standardAC 60 Hz Pilot valve

R412009278 - Plug, EN 175301-803, form C ISO 15217R412009279 1.6 VA Plug, EN 175301-803, form C ISO 15217R412009280 1.6 VA Plug, EN 175301-803, form C ISO 15217R412009378 - Plug, M12x1 -R412009283 - Plug, EN 175301-803, form C ISO 15217R412009284 1.6 VA Plug, EN 175301-803, form C ISO 15217R412009285 1.6 VA Plug, EN 175301-803, form C ISO 15217

Part No. basic valve with electrical connector

R412009277 Basic valve without pilot valveR412009286 Basic valve without pilot valve, with CNOMO subbaseR412009282 Basic valve without pilot valveR412009287 Basic valve without pilot valve, with CNOMO subbaseR412009278 Basic valve with pilot valveR412009279 Basic valve with pilot valveR412009280 Basic valve with pilot valveR412009378 Basic valve with pilot valveR412009283 Basic valve with pilot valveR412009284 Basic valve with pilot valveR412009285 Basic valve with pilot valve

Part No. Reverse polarity protection Weight Fig.

R412009277 - 1.96 lbs Fig. 1 1)R412009286 - 1.97 lbs Fig. 2 1)R412009282 - 1.96 lbs Fig. 1 1)R412009287 - 1.97 lbs Fig. 2 1)R412009278 Protected against polarity reversal 2.04 lbs Fig. 3 -R412009279 Protected against polarity reversal 2.04 lbs Fig. 3 -R412009280 Protected against polarity reversal 2.04 lbs Fig. 3 -R412009378 - 1.98 lbs Fig. 4 2)R412009283 Protected against polarity reversal 2.04 lbs Fig. 3 -R412009284 Protected against polarity reversal 2.04 lbs Fig. 3 -R412009285 Protected against polarity reversal 2.04 lbs Fig. 3 -

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi1) Suitable for use in Ex zones 1, 2, 21, 222) With adjustment screw lock

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.ATEX optional: The ATEX ID depends on the selected pilot valve.Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these mayprevent through connection of components.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 68: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 68 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Fig. 1: Filling unit without pilot valve with porting configuration for series DO16

A1 = inputA2 = outputA3 = ventilation port1) Adjustment screw for filling time

DimensionsDimensions in mm

A2 A3 B C D F K M

G 3/4 G 1/2 170 103 109 125 103.5 58G 1 G 1/2 170 103 109 125 103.5 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 69: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 69 | AVENTICS

Dimensions

Fig. 2: Filling unit with transition plate for pilot valve series DO30

A1 = inputA2 = outputA3 = ventilation port1) Transition plate with CNOMO porting configuration for pilot valve DO302) Adjustment screw for filling time

DimensionsDimensions in mm

A1 A2 A3 B C D E1 F K M N Q

G 3/4 G 3/4 G 1/2 170 103 109 14.2 125 103.5 58 M4 21G 1 G 1 G 1/2 170 103 109 14.2 125 103.5 58 M4 21

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 70: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 70 | AVENTICS

Dimensions

Fig. 3: Filling unit with pilot valve and port for electrical connector form C

A1 = inputA2 = outputA3 = ventilation port1) Connection for valve plug connector according to ISO 15217 (form C)2) Manual override3) Adjustment screw for filling time

DimensionsDimensions in mm

A1 A2 A3 B C D E1 F K M

G 3/4 G 3/4 G 1/2 170 103 109 25.1 125 103.5 58G 1 G 1 G 1/2 170 103 109 25.1 125 103.5 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 71: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 71 | AVENTICS

Dimensions

Fig. 4: Filling unit with pilot valve push-in fitting M12x1

A1 = inputA2 = outputA3 = ventilation port1) plug M122) Manual override3) Adjustment screw for filling time

DimensionsDimensions in mm

A1 A2 A3 B C D E1 F M

G 1 G 1 G 1/2 170 103 109 39 125 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 72: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 72 | AVENTICS

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)1) Switching point: adjustable filling time, fixed change-over pressure ≈ 0.5 x p1 (50%)2) Throttle fully opened* Adjustment screw rotations

DiagramsFlow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 73: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 73 | AVENTICS

Pin assignments

Pin assignment M12x1

3: +/-4: +/-

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 74: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 74 | AVENTICS

Filling unit, electrically operated,Series AS5-SSU- adjustable filling time and change-over pressure, Increased flow rate 2▶3- Compressed air connection G 1- Pipe connection- Electrical connection: Plug, M12x1- ATEX optional

Version Poppet valve, Can be assembled intoblocks

Parts Filling valve, 3/2-directional valve,electrically operated

Nominal flow 8.89 CvNominal flow 1 ▶ 2 8.89 CvNominal flow 2 ▶ 3 3.76 CvWorking pressure min./max. 37 ... 130 psiMedium Compressed air, Neutral gasesMedium temperature min./max. 14 ... 122 °FAmbient temperature min./max. 14 ... 122 °FPilot InternalSealing principle Soft sealingMax. particle size 25 µmProtection class acc. to DIN EN61140,with plug

IP65

Duty cycle 100 %Weight 2.04 lbs

Technical data

Part No. Compressed air connection input Compressed air connection output Exhaust

R412009381 G 1 G 1 G 1/2

Part No. Operationalvoltage

Power consumption Electrical connection

DC DC Pilot valveR412009381 24 V 2 W Plug, M12x1

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi, MO = Manual override

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.Actuating the electric priority circuit disrupts the slow pressure build-up and pressure p1 is immediately applied.Rear exhaust flow rate 2▶3 substantially increasedDo not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these mayprevent through connection of components.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 75: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 75 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = ventilation port1) plug M122) Manual override3) Adjustment screw lock4) Adjustment screw for filling time

DimensionsDimensions in mm

A1 A2 A3 B C D E1 F K M

G 1 G 1 G 1/2 170 103 109 39 125 103.5 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 76: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 76 | AVENTICS

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)Change-over pressure individually adjustable via electrical signal1) Switching point: adjustable filling time and change-over pressure

DiagramsFlow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 77: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 77 | AVENTICS

DiagramsRear exhaust 2 3

p2 = secondary pressureqn = nominal flow

Pin assignments

Pin assignment M12x1

3: +/-4: +/-

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 78: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 78 | AVENTICS

Filling unit, pneumatically operated,Series AS5-SSU- adjustable filling time- Compressed air connection G 3/4, G 1- Pipe connection- ATEX optional

Version Poppet valve, Can be assembled intoblocks

Pilot InternalSealing principle Soft sealingWorking pressure min./max. 0 ... 232 psiControl pressure min./max. 37 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesMax. particle size 40 µmWeight 2.04 lbs

Technical data

Part No. Port Pilot connection Exhaust Flow Flow FlowQn Qn 1▶2 Qn 2▶3

R412009276 G 3/4 G 1/8 G 1/2 8.89 Cv 8.89 Cv 3.76 Cv 1)R412009281 G 1 G 1/8 G 1/2 8.89 Cv 8.89 Cv 3.76 Cv 1)R412009289 G 1 G 1/8 G 1/2 8.89 Cv 8.89 Cv 3.76 Cv 2)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi1)  2) With adjustment screw lock

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these mayprevent through connection of components.Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 79: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 79 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = ventilation portA5 = control pressure connection1) Adjustment screw for filling time2) Adjustment screw lock

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 80: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 80 | AVENTICS

DimensionsDimensions in mm

A1 A2 A3 A5 B C D E1 F K M

G 3/4 G 3/4 G 1/2 G 1/8 170 103 109 20.2 125 103.5 58G 1 G 1 G 1/2 G 1/8 170 103 109 20.2 125 103.5 58

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)1) Switching point: adjustable filling time, fixed change-over pressure ≈ 0.5 x p1 (50%)2) Throttle fully opened* Adjustment screw rotations

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 81: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 81 | AVENTICS

DiagramsFlow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 82: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 82 | AVENTICS

Filling unit, pneumatically operated,Series AS5-SSU- adjustable filling time and change-over pressure- Compressed air connection G 1- Pipe connection

Version Poppet valve, Can be assembled intoblocks

Pilot InternalSealing principle Soft sealingWorking pressure min./max. 0 ... 232 psiControl pressure min./max. 37 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesMax. particle size 25 µmDuty cycle 100 %Protection class according to EN60529:2000, without electrical connector

IP65

Weight 2.04 lbs

Technical data

Part No. Port Pilot connection Exhaust Flow Flow FlowQn Qn 1▶2 Qn 2▶3

R412009379 G 1 G 1/8 G 1/2 8.89 Cv 8.89 Cv 3.76 Cv

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.Actuating the electric priority circuit disrupts the slow pressure build-up and pressure p1 is immediately applied.Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these mayprevent through connection of components.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 83: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 83 | AVENTICS

Material

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = ventilation portA5 = control pressure connection1) plug M122) Manual override3) Adjustment screw for filling time4) Adjustment screw lock

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 84: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 84 | AVENTICS

DimensionsDimensions in mm

A1 A2 A3 A5 B C D E1 F K

G 1 G 1 G 1/2 G 1/8 170 103 109 39 125 103.5

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)Change-over pressure individually adjustable via electrical signal1) Switching point: adjustable filling time and change-over pressure

DiagramsFlow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 85: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 85 | AVENTICS

Pin assignments

Pin assignment M12x1

3: +/-4: +/-

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 86: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 86 | AVENTICS

Filling valve, Series AS5-SSV- adjustable filling time- Compressed air connection G 3/4, G 1

Version Poppet valve, Can be assembled intoblocks

Sealing principle Soft sealingWorking pressure min./max. 37 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesMax. particle size 40 µmWeight 0.948 lbs

Technical data

Part No. Port FlowQn

R412009272 G 3/4 10.16 Cv 1)R412009273 G 1 10.16 Cv 1)R412009275 G 1 10.16 Cv 2)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi1) Suitable for use in Ex zones 1, 2, 21, 222) With adjustment screw lock

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these mayprevent through connection of components.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 87: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 87 | AVENTICS

Material

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = output1) Adjustment screw for filling time2) Adjustment screw lock

DimensionsDimensions in mm

A1 A2 B C D F M

G 3/4 G 3/4 85 103 109 112 58G 1 G 1 85 103 109 112 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 88: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 88 | AVENTICS

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)1) Switching point: adjustable filling time, fixed change-over pressure ≈ 0.5 x p1 (50%)2) Throttle fully opened* Adjustment screw rotations

DiagramsFlow rate characteristic

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 89: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 89 | AVENTICS

Filling valve, pneumatically operated,Series AS5-SSV- adjustable filling time and change-over pressure- Compressed air connection G 3/4, G 1- Pipe connection

Version Poppet valve, Can be assembled intoblocks

Sealing principle Soft sealingWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesMax. particle size 40 µmWeight 0.948 lbs

Technical data

Part No. Port Pilot connection Flow Working pressure min./max.Qn 1▶2

R412009311 G 3/4 G 1/8 10.16 Cv 15 ... 232 psiR412009312 G 1 G 1/8 10.16 Cv 37 ... 232 psi

Nominal flow Qn at p1 = 91.35 psi and Δp = 14.5 psi

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 90: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 90 | AVENTICS

Material

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = control pressure connection1) Adjustment screw for filling time

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 91: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 91 | AVENTICS

Change-over pressure individually adjustable via pneumatic signal1) Switching point: adjustable filling time and change-over pressure

DiagramsFlow rate characteristic

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 92: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 92 | AVENTICS

Filling valve, electrically operated,series AS5-SSV- adjustable filling time and change-over pressure, Electr. connection: valve plug connectorM12x1- Compressed air connection G 3/4, G 1

Version Poppet valve with elect. priority circuit,Can be assembled into blocks

Sealing principle Soft sealingWorking pressure min./max. 37 ... 145 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesMax. particle size 25 µmDuty cycle 100 %Protection class according to EN60529:2000, without electrical connector

IP65

Weight 0.948 lbs

Technical data

Part No. Port FlowQn

R412009373 G 3/4 10.16 CvR412009374 G 1 10.16 Cv

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a restart after a mains pressurefailure or avoids emergency OFF switching. This also avoids dangerous, jerky cylinder movements.Actuating the electric priority circuit disrupts the slow pressure build-up and pressure p1 is immediately applied.Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these mayprevent through connection of components.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 93: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 93 | AVENTICS

Material

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = output1) plug M122) Manual override3) Adjustment screw for filling time4) Adjustment screw lock

DimensionsDimensions in mm

A1 A2 B C D E1 F M

G 3/4 G 3/4 85 103 109 39 112 58G 1 G 1 85 103 109 39 112 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 94: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 94 | AVENTICS

Diagrams

Secondary pressure while filling

p1 = working pressurep2 = secondary pressuret = filling time, adjustable via adjustment screw (throttle)Change-over pressure individually adjustable via electrical signal1) Switching point: adjustable filling time and change-over pressure

DiagramsFlow rate characteristic

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 95: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 95 | AVENTICS

Pin assignments

Pin assignment M12x1

3: +/-4: +/-

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 96: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 96 | AVENTICS

2/2-directional valve, electricallyoperated, Series AS5-SOV- Compressed air connection G 1- Pipe connection- NC- Electrical connection: Plug, ISO 15217, form C

Version Poppet valve, Can be assembled intoblocks

Parts 2/2-directional valve, electrically operatedNominal flow 12.7 CvWorking pressure min./max. 44 ... 145 psiMedium Compressed air, Neutral gasesMedium temperature min./max. 14 ... 122 °FAmbient temperature min./max. 14 ... 122 °FSealing principle Soft sealingMax. particle size 25 µmConnector standard ISO 15217Protection class acc. to DIN EN61140,with plug

IP65

Duty cycle 100 %Weight 2.5 lbs

Technical data

Part No. Compressed air connectioninput

Compressed air connection output Operationalvoltage

DCR412009301 G 1 G 1 24 V

Part No. Power consumption Electrical connection basic valve with electrical connectorDC Pilot valve

R412009301 2 W Plug, ISO 15217, form C Basic valve with pilot valve

Part No. Reverse polarity protection

R412009301 Protected against polarity reversal

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi, MO = Manual override

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 97: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 97 | AVENTICS

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = output1) Connection for valve plug connector according to ISO 15217 (form C)2) Manual override

DimensionsDimensions in mm

A1 A2 B C D E1 F

G 1 G 1 85 103 109 25.1 125

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 98: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 98 | AVENTICS

Diagrams

Flow rate characteristic 1 2

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 99: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 99 | AVENTICS

3/2-directional valve, electricallyoperated, Series AS5-SOV- Compressed air connection G 3/4, G 1- Pipe connection- ATEX optional

Version Poppet valve, Can be assembled intoblocks

Parts 3/2-directional valve, electrically operatedNominal flow 12.7 CvNominal flow 1 ▶ 2 12.7 CvNominal flow 2 ▶ 3 3.76 CvWorking pressure min./max. 37 ... 145 psiMedium Compressed air, Neutral gasesMedium temperature min./max. 14 ... 122 °FAmbient temperature min./max. 14 ... 122 °FSealing principle Soft sealingMax. particle size 5 µmProtection class acc. to DIN EN61140,with plug

See table below

Weight See table below

Technical data

Part No. Compressed air connection input Compressed air connection output Exhaust

R412009265 G 3/4 G 3/4 G 1/2R412009266 G 3/4 G 3/4 G 1/2R412009267 G 3/4 G 3/4 G 1/2R412009269 G 1 G 1 G 1/2R412009270 G 1 G 1 G 1/2R412009271 G 1 G 1 G 1/2R412009264 G 3/4 G 3/4 G 1/2R412009258 G 3/4 G 3/4 G 1/2R412009268 G 1 G 1 G 1/2R412009376 G 1 G 1 G 1/2R412009259 G 1 G 1 G 1/2

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 HzR412009265 24 V - -R412009266 - 110 V 110 VR412009267 - 220 V 230 VR412009269 24 V - -R412009270 - 110 V 110 VR412009271 - 220 V 230 VR412009264 - - -R412009258 - - -R412009268 - - -

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 100: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 100 | AVENTICS

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 HzR412009376 24 V - -R412009259 - - -

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

R412009265 2 W - - -R412009266 - 1.6 VA 1.4 VA 2.2 VAR412009267 - 1.6 VA 1.4 VA 2.2 VAR412009269 2 W - - -R412009270 - 1.6 VA 1.4 VA 2.2 VAR412009271 - 1.6 VA 1.4 VA 2.2 VAR412009264 - - - -R412009258 - - - -R412009268 - - - -R412009376 2 W - - -R412009259 - - - -

Part No. Switch-on power Protection class Electrical connection Connector standardAC 60 Hz Pilot valve

R412009265 - IP65 Plug, ISO 15217, form C ISO 15217R412009266 1.6 VA IP65 Plug, ISO 15217, form C ISO 15217R412009267 1.6 VA IP65 Plug, ISO 15217, form C ISO 15217R412009269 - IP65 Plug, ISO 15217, form C ISO 15217R412009270 1.6 VA IP65 Plug, ISO 15217, form C ISO 15217R412009271 1.6 VA IP65 Plug, ISO 15217, form C ISO 15217R412009264 - - - -R412009258 - - - -R412009268 - - - -R412009376 - IP65 Plug, M12x1 -R412009259 - - - -

Part No. basic valve with electrical connector

R412009265 Basic valve with pilot valveR412009266 Basic valve with pilot valveR412009267 Basic valve with pilot valveR412009269 Basic valve with pilot valveR412009270 Basic valve with pilot valveR412009271 Basic valve with pilot valveR412009264 Basic valve without pilot valveR412009258 Basic valve without pilot valve, with CNOMO subbaseR412009268 Basic valve without pilot valveR412009376 Basic valve with pilot valveR412009259 Basic valve without pilot valve, with CNOMO subbase

Part No. Reverse polarity protection Weight Fig.

R412009265 Protected against polarity reversal 1.49 lbs Fig. 3 -R412009266 Protected against polarity reversal 1.49 lbs Fig. 3 -

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 101: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 101 | AVENTICS

Part No. Reverse polarity protection Weight Fig.

R412009267 Protected against polarity reversal 1.49 lbs Fig. 3 -R412009269 Protected against polarity reversal 1.49 lbs Fig. 3 -R412009270 Protected against polarity reversal 1.49 lbs Fig. 3 -R412009271 Protected against polarity reversal 1.49 lbs Fig. 3 -R412009264 - 1.41 lbs Fig. 1 1)R412009258 - 1.37 lbs Fig. 2 1)R412009268 - 1.41 lbs Fig. 1 1)R412009376 - 1.43 lbs Fig. 4 -R412009259 - 1.37 lbs Fig. 2 1)

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi, MO = Manual override1) Suitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .ATEX optional: The ATEX ID depends on the selected pilot valve.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 102: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 102 | AVENTICS

Dimensions

Fig. 1: 3/2-directional valve without pilot valve with porting configuration for series DO16

A1 = inputA2 = outputA3 = ventilation port1) For pilot valve series DO16

DimensionsDimensions in mm

A1 A2 A3 B C D F M

G 3/4 G 3/4 G 1/2 63 103 80 125 42.5G 1 G 1 G 1/2 63 103 80 125 42.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 103: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 103 | AVENTICS

Dimensions

Fig. 2: 3/2 directional valve with transition plate (suitable for ATEX)

A1 = inputA2 = outputA3 = ventilation port1) Shut-off valve2) Transition plate3) Pilot valve4) Coil5) Electrical connectorSee accessories for pilot valve and coil

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 104: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 104 | AVENTICS

DimensionsFig. 3: 3/2 directional valve with pilot valve and connection for valve plug connector

A1 = inputA2 = outputA3 = ventilation port1) For valve plug connectors according to ISO 15217 (form C)2) Manual override

DimensionsDimensions in mm

A1 A2 A3 B C D F M

G 3/4 G 3/4 G 1/2 85 103 109 125 58G 1 G 1 G 1/2 85 103 109 125 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 105: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 105 | AVENTICS

Dimensions

Fig. 4: 3/2-directional valve with pilot valve push-in fitting M12x1

A1 = inputA2 = outputA3 = ventilation port1) plug M122) Manual override

DimensionsDimensions in mm

A1 A2 A3 B C D F M

G 1 G 1 G 1/2 85 103 109 125 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 106: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 106 | AVENTICS

Diagrams

Flow rate characteristic 1 2

p2 = secondary pressureqn = nominal flow

DiagramsRear exhaust 2 3

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 107: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 107 | AVENTICS

Pin assignments

Pin assignment M12x1

3: +/-4: +/-

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 108: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 108 | AVENTICS

3/2-directional valve, electricallyoperated, Series AS5-SOV-...-POS- With position inquiry, with integrated sensor- Compressed air connection G 3/4, G 1- Electrical connection: Plug, ISO 15217, form C

Version Poppet valve, Can be assembled intoblocks

Parts 3/2-directional valve, electrically operatedNominal flow 12.7 CvNominal flow 1 ▶ 2 12.7 CvNominal flow 2 ▶ 3 3.76 CvWorking pressure min./max. 37 ... 145 psiMedium Compressed air, Neutral gasesMedium temperature min./max. 14 ... 122 °FAmbient temperature min./max. 14 ... 122 °FSealing principle Soft sealingMax. particle size 25 µmProtection class acc. to DIN EN61140,with plug

IP65

Weight 1.01 lbs

Technical data

Part No. Compressed air connection input Compressed air connection output Exhaust

R412009382 G 3/4 G 3/4 G 1/2R412009388 G 1 G 1 G 1/2

Part No. Operationalvoltage

Power consumption Electrical connection

DC DC Pilot valveR412009382 24 V 2 W Plug, ISO 15217, form CR412009388 24 V 2 W Plug, ISO 15217, form C

Part No. Electrical connection Cable lengthSensor Sensor

R412009382 without wire end ferrule, tin-plated 3 mR412009388 without wire end ferrule, tin-plated 3 m

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psi

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 109: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 109 | AVENTICS

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .An ST6 sensor (contactless) is used to detect the switching position in the non-actuated state (position: exhaust).The sensor signal is visible on the front of the coverElectronic sensor R412003658 included in scope of delivery (assembled).For sensor connection, see the selection table.A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 110: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 110 | AVENTICS

Dimensions

3/2-directional valve with pilot valve and port for electrical connector form C

A1 = inputA2 = outputA3 = ventilation port1) Electr. connection: valve plug connector form C, ISO 152172) Manual override3) For version with sensor: cable length 3 m PUR.4) Optical switch status indicator

DimensionsDimensions in mm

A1 A2 A3 B C D F M

G 3/4 G 3/4 G 1/2 85 103 109 125 58G 1 G 1 G 1/2 85 103 109 125 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 111: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 111 | AVENTICS

Diagrams

Flow rate characteristic 1 2

p2 = secondary pressureqn = nominal flow

DiagramsRear exhaust 2 3

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 112: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 112 | AVENTICS

Pin assignments

Sensor pin assignment tin-plated wire ends

BN = brownBK = blackBU = blue

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 113: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 113 | AVENTICS

3/2-directional valve, pneumaticallyoperated, Series AS5-SOV- Compressed air connection G 3/4, G 1- Pipe connection- suitable for ATEX

Version Poppet valve, Can be assembled intoblocks

Sealing principle Soft sealingCertificates suitable for ATEXWorking pressure min./max. 0 ... 232 psiControl pressure min./max. 37 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesWeight 1.01 lbs

Technical data

Part No. Port Pilot connection Exhaust Flow Flow FlowQn Qn 1▶2 Qn 2▶3

R412009262 G 3/4 G 1/8 G 1/2 12.7 Cv 12.7 Cv 3.76 CvR412009263 G 1 G 1/8 G 1/2 12.7 Cv 12.7 Cv 3.76 Cv

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 114: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 114 | AVENTICS

Material

Threaded bushing Die cast zinc

Dimensions

Dimensions

A1 = inputA2 = outputA3 = ventilation portA5 = control pressure connection

DimensionsDimensions in mm

A1 A2 A3 A5 B C D E1 F M

G 3/4 G 3/4 G 1/2 G 1/8 85 103 109 20.2 125 58G 1 G 1 G 1/2 G 1/8 85 103 109 20.2 125 58

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 115: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 115 | AVENTICS

Diagrams

Flow rate characteristic 1 2

p2 = secondary pressureqn = nominal flow

DiagramsRear exhaust 2 3

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 116: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 116 | AVENTICS

Diagramscontrol pressure characteristic

minimum pilot pressure depending on working pressurePS = control pressureP= Working pressure

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 117: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 117 | AVENTICS

3/2-shut-off valve, mechanicallyoperated, Series AS5-BAV- G 3/4, G 1- lockable- for padlocks- suitable for ATEX

Version Ball valveActivation MechanicalLock type lockableActuating element rotary switchSealing principle metal/metal sealingCertificates suitable for ATEXWorking pressure min./max. 0 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesMax. particle size 25 µmWeight 1.82 lbs

Technical data

Part No. Compressed air connection Compressed air connectionInput Output

R412009260 G 3/4 G 3/4R412009261 G 1 G 1

Part No. Compressed air connection Flow Flow Lock typeExhaust Qn 1 ▶ 2 Qn 2▶3

R412009260 G 3/4 30.49 Cv 0.132 Cv for padlocksR412009261 G 3/4 30.49 Cv 0.132 Cv for padlocks

Part No. Locking base

R412009260 Steel, galvanizedR412009261 Steel, galvanized

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 118: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 118 | AVENTICS

The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Polytetrafluorethylene

Threaded bushing Die cast zinc

Actuating element Polyoxymethylene

Locking base Steel, galvanized

Dimensions

Dimensions

A1 = inputA2 = outputA3 = ventilation port1) Mounting option for padlocks, max. shackle Ø 8

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 119: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 119 | AVENTICS

DimensionsDimensions in mm

A2 A3 B C D E1 M

G 3/4 G 3/4 85 103 109 36 58G 1 G 3/4 85 103 109 36 58

Diagrams

Flow rate characteristic

p2 = secondary pressureqn = nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 120: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 120 | AVENTICS

Distributor, Series AS5-DIS- G 3/4, G 1- Distributor 2x- Distributor- suitable for ATEX

Version Distributor, Can be assembled into blocksParts DistributorMounting orientation AnyCertificates suitable for ATEXWorking pressure min./max. 0 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gasesWeight 1.43 lbs

Technical data

Part No. Port Nominal flow Nominal flow Nominal flowQn 1▶2 Qn 1▶3 Qn 1▶5

R412009250 G 3/4 18.29 Cv 8.64 Cv 12.2 CvR412009251 G 1 18.29 Cv 8.64 Cv 12.2 Cv

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

Suitable for direct mounting of a PE1 and PM1 series pressure sensor (flange version)Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 121: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 121 | AVENTICS

Dimensions

Dimensions

A1 = inputA2 = outputA3 = outputA5 = output1) Mounting thread for pressure sensor

DimensionsDimensions in mm

A1 A2 A3 A5 B C D M N Q S1 S2

G 3/4 G 3/4 G 3/4 G 3/4 85 103 109 58 M5 20 44.5 22G 1 G 1 G 3/4 G 3/4 85 103 109 58 M5 20 44.5 22

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 122: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 122 | AVENTICS

Distributor, Series AS5-DIN- G 3/4, G 1- Non-return valve- suitable for ATEX

Version Non-return valve, Can be assembled intoblocks

Parts DistributorMounting orientation AnyCertificates suitable for ATEXWorking pressure min./max. 6 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, Neutral gases

Technical data

Part No. Port Nominal flowQn 1▶2

R412009252 G 3/4 16.26 CvR412009253 G 1 16.26 Cv

Nominal flow Qn with secondary pressure p2 = 87 psi at Δp = 14.5 psiSuitable for use in Ex zones 1, 2, 21, 22

Suitable for use in Ex zones 1, 2, 21, 22A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about thevertical axis. Please see the operating instructions for further details.

Technical information

Technical information

Material

Housing Polyamide

Front plate Acrylonitrile butadiene styrene

Seals Acrylonitrile butadiene rubber

Threaded bushing Die cast zinc

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 123: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 123 | AVENTICS

Dimensions

usage

1) Filter pressure regulator2) Non-return valve3) Lubricator4) Compressed air

DimensionsDimensions

A1 = inputA2 = output

DimensionsDimensions in mm

A1 A2 B C D

G 3/4 G 3/4 85 103 112G 1 G 1 85 103 112

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 124: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 124 | AVENTICS

Diagrams

Flow rate characteristic

p1 = Working pressurep2 = Secondary pressureqn = Nominal flow

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 125: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 125 | AVENTICS

Reservoir, Series AS5-CLS/ -CLP/ -CLC- for filters, pre-filters and microfilters- Material Polycarbonate, Die cast zinc- suitable for ATEX

Version ReservoirCertificates suitable for ATEXWorking pressure min./max. 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed airFilter reservoir volume 2.94 fl.oz.Weight See table below

Technical data

Part No. Condensate drain Reservoir

R412009338 semi-automatic, open without pressure PolycarbonateR412009339 fully automatic, open without pressure PolycarbonateR412009340 fully automatic, closed without pressure PolycarbonateR412009344 semi-automatic, open without pressure Die cast zinc, with windowR412009345 fully automatic, open without pressure Die cast zinc, with windowR412009346 fully automatic, closed without pressure Die cast zinc, with window

Part No. Protective guard Weight Fig.

R412009338 Polyamide 0.19 lbs Fig. 1R412009339 Polyamide 0.256 lbs Fig. 2R412009340 Polyamide 0.256 lbs Fig. 2R412009344 - 1.5 lbs Fig. 1R412009345 - 1.63 lbs Fig. 2R412009346 - 1.63 lbs Fig. 2

Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 126: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 126 | AVENTICS

Dimensions

Fig. 1

Dimensions

Part No. A B C

R412009338 60 165.3 64.7R412009344 60 165.3 64.7

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 127: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 127 | AVENTICS

Dimensions

Fig. 2

Dimensions

Part No. A4 A B

R412009339 G 1/8 60 182R412009340 G 1/8 60 182R412009345 G 1/8 60 182R412009346 G 1/8 60 182

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 128: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 128 | AVENTICS

Reservoir, Series AS5-CLA- for active carbon filter- Material Polycarbonate, Die cast zinc- suitable for ATEX

Version ReservoirCertificates suitable for ATEXWorking pressure min./max. 0 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed airFilter reservoir volume 2.94 fl.oz.Weight See table below

Technical data

Part No. Reservoir Protective guard Weight

R412009347 Polycarbonate Polyamide 0.19 lbsR412009349 Die cast zinc, with window - 1.7 lbs

Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 129: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 129 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. A B

R412009347 60 157.5R412009349 60 157.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 130: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 130 | AVENTICS

Reservoir, Series AS5-CBS- for lubricator- Material Polycarbonate, Die cast zinc- suitable for ATEX

Version ReservoirCertificates suitable for ATEXWorking pressure min./max. 0 ... 232 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed air, OilLubricator reservoir volume 6.12 fl.oz.Weight See table below

Technical data

Part No. Electrical level indicator Reservoir Protective guard Weight

R412009351 with external query Polycarbonate Polyamide 0.19 lbsR412009352 - Polycarbonate Polyamide 0.738 lbsR412009358 - Die cast zinc, with window - 1.5 lbs

Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Reservoir Polycarbonate, Die cast zinc

Protective guard Polyamide

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 131: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 131 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. A B

R412009351 60 154.8R412009352 60 154.8R412009358 60 154.8

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 132: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 132 | AVENTICS

Mounting plate, Series AS5-MBR-...-Ambient temperature min./max. 14 ... 122 °FWeight 0.869 lbs

Technical data

Part No.

R412009368

Scope of delivery incl. 2 mounting screws 3x10 (Torx 10 IP) DIN EN ISO 10664

Technical information

Material

Housing Steel, galvanized

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 133: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 133 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. A C D E F H I L M N O P R T U

R412009368 70 52 172 79 3 82 121 22 45 18.5 98 6.5 7 16 124

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 134: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 134 | AVENTICS

Mounting clip, Series AS5-MBR-...-W03Ambient temperature min./max. 14 ... 122 °FWeight 0.264 lbs

Technical data

Part No.

R412009370

Scope of delivery incl. 2 mounting screws M6x90-4.8-A2R according to EN ISO 7046-1 (countersunk screw with type H X-slot), 1x O-ringSuitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Housing Polyamide

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 135: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 135 | AVENTICS

Dimensions

Dimensions

L = Mounting screwM = O-ring

Dimensions

Part No. A B C D E F G H I K L M N

R412009370 162 102 140 10 57 8.5 10 17.5 10 87 M6x90 37x2,3 138.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 136: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 136 | AVENTICS

Block assembly kit, Series AS5-MBR-...-W04

Ambient temperature min./max. 14 ... 122 °FWeight 0.165 lbs

Technical data

Part No.

R412009371

Scope of delivery incl. 2 mounting screws M6x90-4.8-A2R according to EN ISO 7046-1 (countersunk screw with type H X-slot), 1x O-ringSuitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Housing Polyamide

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 137: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 137 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. B C D L M

R412009371 102 57 17 M6x90 37x2,3

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 138: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 138 | AVENTICS

Block assembly kit, Series AS5-MBR-...-W05- G 3/4 - G 1

Ambient temperature min./max. 14 ... 122 °FWeight 1.5 lbs

Technical data

Part No. Port

R412009366 G 3/4R412009367 G 1

Scope of delivery incl. 4 mounting screws M6x90-4.8-A2R according to EN ISO 7046-1 (countersunk screw with type H X-slot), 2x O-ring

Technical information

Material

Housing Die cast zinc, painted

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 139: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 139 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. A1 A B C1 C2 D E F G H I J K L M N

R412009366 G 3/4 160 102 72.5 72.5 10 57 8.4 10 30 10 127 41 M6x90 37x2,3 87R412009367 G 1 160 102 72.5 72.5 10 57 8.4 10 30 10 127 41 M6x90 37x2,3 87

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 140: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 140 | AVENTICS

Block assembly kit, Series AS3/AS5-MBR-...-W07

Ambient temperature min./max. 14 ... 122 °F

Technical data

Part No. Port

R412010122 G 1/4

scope of delivery incl. seal

Technical information

Material

Housing Polyamide

Seal Acrylonitrile butadiene rubber

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 141: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 141 | AVENTICS

Dimensions

DimensionsDimensions in mm

Part No. A B C D

R412010122 102 80 18 G 1/4

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 142: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 142 | AVENTICS

Panel nut, Series AS-MBR-...-W06- for AS5, NL4

Weight 0.02 lbsThe delivered product may vary from thatin the illustration.

Technical data

Part No. Port Scope of delivery

1829234071 M50x1.5 2 piece

Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Housing Plastic

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 143: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 143 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. For series A B C

1829234071 AS5, NL4 M50x1,5 64 7.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 144: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 144 | AVENTICS

Pressure gauge, Series PG1-SAS- Back port- Background color Black- Scale color White, Grey- Viewing window Polystyrene- Units bar- Units psi

Version Bourdon tube pressure gaugeStandardization EN 837-1Class 2,5Ambient temperature min./max. -40 ... 140 °FMedium Compressed airMain scale unit (outside) barMain scale color (outside) WhiteSecondary scale unit (inside) psiSecondary scale color (inside) GreyBackground color BlackPointer color WhiteWeight See table below

Technical data

Part No. Compressed airconnection

Nominaldiameter

Range of application Display range Operating pressure Scale value

R412004407 G 1/4 1.57 inch 0 ... 1.2 bar 0 ... 1.6 bar 0 ... 23 psi 0.05R412004408 G 1/4 1.57 inch 0 ... 2 bar 0 ... 2.5 bar 0 ... 36 psi 0.1R412004409 G 1/4 1.57 inch 0 ... 3.2 bar 0 ... 4 bar 0 ... 58 psi 0.1R412004410 G 1/4 1.57 inch 0 ... 4 bar 0 ... 6 bar 0 ... 87 psi 0.2R412004411 G 1/4 1.57 inch 0 ... 8 bar 0 ... 10 bar 0 ... 145 psi 0.2R412004412 G 1/4 1.57 inch 0 ... 12 bar 0 ... 16 bar 0 ... 232 psi 0.5R412004413 G 1/4 1.97 inch 0 ... 1.2 bar 0 ... 1.6 bar 0 ... 23 psi 0.05R412004414 G 1/4 1.97 inch 0 ... 2 bar 0 ... 2.5 bar 0 ... 36 psi 0.1R412004415 G 1/4 1.97 inch 0 ... 3.2 bar 0 ... 4 bar 0 ... 58 psi 0.1R412004416 G 1/4 1.97 inch 0 ... 4 bar 0 ... 6 bar 0 ... 87 psi 0.2R412004417 G 1/4 1.97 inch 0 ... 8 bar 0 ... 10 bar 0 ... 145 psi 0.2R412004418 G 1/4 1.97 inch 0 ... 12 bar 0 ... 16 bar 0 ... 232 psi 0.5R412007898 G 1/4 1.97 inch 0 ... 20 bar 0 ... 25 bar 0 ... 362 psi 1R412004419 G 1/4 2.48 inch 0 ... 1.2 bar 0 ... 1.6 bar 0 ... 23 psi 0.05R412004420 G 1/4 2.48 inch 0 ... 2 bar 0 ... 2.5 bar 0 ... 36 psi 0.1R412004421 G 1/4 2.48 inch 0 ... 3.2 bar 0 ... 4 bar 0 ... 58 psi 0.1R412004422 G 1/4 2.48 inch 0 ... 4 bar 0 ... 6 bar 0 ... 87 psi 0.2R412004423 G 1/4 2.48 inch 0 ... 8 bar 0 ... 10 bar 0 ... 145 psi 0.2R412004424 G 1/4 2.48 inch 0 ... 12 bar 0 ... 16 bar 0 ... 232 psi 0.5

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 145: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 145 | AVENTICS

Part No. Weight

R412004407 0.176 lbs -R412004408 0.176 lbs -R412004409 0.176 lbs -R412004410 0.176 lbs -R412004411 0.176 lbs -R412004412 0.176 lbs -R412004413 0.198 lbs -R412004414 0.198 lbs -R412004415 0.198 lbs -R412004416 0.198 lbs -R412004417 0.198 lbs 1)R412004418 0.198 lbs 1)R412007898 0.198 lbs -R412004419 0.22 lbs -R412004420 0.22 lbs -R412004421 0.22 lbs -R412004422 0.22 lbs -R412004423 0.22 lbs -R412004424 0.22 lbs -

1) Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Housing Acrylonitrile butadiene styrene

Thread Brass

Viewing window Polystyrene

Seal Polytetrafluorethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 146: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 146 | AVENTICS

Dimensions

Dimensions

1) Gasket thread

DimensionsDimensions in mm

Compressed air connection Nominal diameter Ø A B C D E F 1) SW

G 1/4 1.57 inch 39 47.5 26.5 13 7.2 3.7 14G 1/4 1.97 inch 49 47.5 26.5 13 7.2 3.7 14G 1/4 2.48 inch 62 47 29 13 7.2 3.7 14

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 147: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 147 | AVENTICS

Pressure gauge, Series PG1-SAS-ADJ- Back port- with adjustable work area display- Background color Black- Scale color White, Grey- Viewing window Polystyrene- Units bar- Units psi

Version Bourdon tube pressure gaugeVersion with adjustable work area displayStandardization EN 837-1Class 2,5Ambient temperature min./max. -40 ... 140 °FMedium Compressed airWork area adjustable work area displayWork Area Display, Color Red, GreenMain scale unit (outside) barMain scale color (outside) WhiteSecondary scale unit (inside) psiSecondary scale color (inside) GreyBackground color BlackPointer color WhiteWeight 0.22 lbs

Technical data

Part No. Compressed airconnection

Nominaldiameter

Range of application Display range Operating pressure Scale value

R412007867 G 1/4 1.97 inch 0 bar ... 1.2 0 bar ... 1.6 0 ... 23 psi 0.05R412007868 G 1/4 1.97 inch 0 bar ... 2 0 bar ... 2.5 0 ... 36 psi 0.1R412007869 G 1/4 1.97 inch 0 bar ... 3.2 0 bar ... 4 0 ... 58 psi 0.1R412007870 G 1/4 1.97 inch 0 bar ... 4 0 bar ... 6 0 ... 87 psi 0.2R412007871 G 1/4 1.97 inch 0 bar ... 8 0 bar ... 10 0 ... 145 psi 0.2R412007872 G 1/4 1.97 inch 0 bar ... 12 0 bar ... 16 0 ... 232 psi 0.5

To set the operating range, the cover (inspection glass) must be removed. To do this, carefully lift the inspection glass by inserting apointed or flat object in the slot provided for this purpose on the housing circumference.

Technical information

Technical information

Material

Housing Acrylonitrile butadiene styrene

Thread Brass

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 148: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 148 | AVENTICS

Material

Viewing window Polystyrene

Seal Polytetrafluorethylene

Dimensions

Dimensions

1) Gasket thread

DimensionsDimensions in mm

Compressed air connection Nominal diameter Ø A B C D E F SW

G 1/4 1.97 inch 49 47.5 26.5 13 7.2 3.7 14

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 149: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 149 | AVENTICS

Pressure gauge, Series PG1-DIM- for differential pressure measurement for prefilters and microfilters- flange version- Background color White- Scale color Black- Viewing window Polystyrene- Units bar- suitable for ATEX

Version Diaphragm pressure gaugeMounting orientation verticalAmbient temperature min./max. 32 ... 140 °FMedium Compressed airColor for differential pressure range Green, RedMain scale unit (outside) barMain scale color (outside) BlackBackground color WhitePointer color BlackWeight 0.28 lbs

Technical data

Part No. Range of application Display range Operating pressure Scale value

1827231072 0 ... 0.5 bar 0 ... 0.5 bar 0 ... 232 psi 0.1

Suitable for use in Ex zones 1, 2, 21, 22

Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Technical information

Material

Housing Polyamide, fiber-glass reinforced

Viewing window Polystyrene

Seal Acrylonitrile butadiene styrene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 150: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 150 | AVENTICS

Dimensions

Dimensions

1) Input pressure p12) Output pressure p23) Mounting screw and 2 O-rings included in scope of delivery

DimensionsDimensions in mm

A B C E F G H

68 52 50 6 24 M5 22

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 151: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 151 | AVENTICS

contamination display- for prefilters and microfilters

Weight 0.055 lbs

Technical data

Part No.

R412006363

2 mounting screws and 2 O-rings supplied loose, Suitable for use in Ex zones 1, 2, 21, 22

Technical information

Material

Material Polyamide

Dimensions

Dimensions

1) Flow direction2) Display in initial state: green (= Δp 0.35 bar )Display turns red on contamination of the filter element (= Δp ≥ 0.35 bar ).

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 152: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 152 | AVENTICS

DimensionsDimensions in mm

Part No. A B C D

R412006363 43 24 5.5 24

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 153: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 153 | AVENTICS

3/2-directional valve, Series DO16- 3/2- Plate connection- Electrical connection : Plug, ISO 15217, form C- Manual override : without detent, with detent- With spring return

Version Poppet valveActivation ElectricallySealing principle Soft sealingWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed airMax. particle size 5 µmOil content of compressed air 0 ... 5 mg/m³Nominal flow 1 ▶ 2 See table belowNominal flow 2 ▶ 3 See table belowProtection class acc. to DIN EN61140,Electrically

Class I

Protection class,with connection IP65Duty cycle 100 %Mounting on manifold strip PRS stripmounting screws M3Weight 0.077 lbs

Technical data

Part No. MO Operationalvoltage

Operationalvoltage

DC AC 50 Hz0820048002 24 V -0820048004 - 24 V0820048005 - -0820048001 - 230 V0820048026 24 V -0820048028 - 24 V0820048101 - 230 V0820048029 - -0820048025 - 230 V0820048102 24 V -0820048126 24 V -

Part No. Operationalvoltage

Voltage tolerance Voltage tolerance Voltage tolerance

AC 60 Hz DC AC 50 Hz AC 60 Hz0820048002 - -10% / +15% - -0820048004 - - -10% / +15% -0820048005 110 V - - -10% / +15%0820048001 - - -10% / +15% -

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 154: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 154 | AVENTICS

Part No. Operationalvoltage

Voltage tolerance Voltage tolerance Voltage tolerance

AC 60 Hz DC AC 50 Hz AC 60 Hz0820048026 - -10% / +15% - -0820048028 - - -10% / +15% -0820048101 - - -10% / +15% -0820048029 110 V - - -10% / +15%0820048025 - - -10% / +15% -0820048102 - -10% / +15% - -0820048126 - -10% / +15% - -

Part No. Power consumption Holding power Holding power Switch-on powerDC AC 50 Hz AC 60 Hz AC 50 Hz

0820048002 2 W - - -0820048004 - 1.6 VA - 2.2 VA0820048005 - - 1.4 VA -0820048001 - 1.6 VA - 2.2 VA0820048026 2 W - - -0820048028 - 1.6 VA - 2.2 VA0820048101 - 1.6 VA - 2.2 VA0820048029 - - 1.4 VA -0820048025 - 1.6 VA - 2.2 VA0820048102 2 W - - -0820048126 2 W - - -

Part No. Switch-on power Nominal flow 1 ▶ 2 Nominal flow 2 ▶ 3 Working pressure min./max.AC 60 Hz

0820048002 - 0.025 Cv 0.036 Cv 0 ... 145 psi0820048004 - 0.025 Cv 0.036 Cv 0 ... 145 psi0820048005 2 VA 0.025 Cv 0.036 Cv 0 ... 145 psi0820048001 - 0.025 Cv 0.036 Cv 0 ... 145 psi0820048026 - 0.025 Cv 0.036 Cv 0 ... 145 psi0820048028 - 0.025 Cv 0.036 Cv 0 ... 145 psi0820048101 - 0.016 Cv 0.019 Cv 0 ... 87 psi0820048029 2 VA 0.025 Cv 0.036 Cv 0 ... 145 psi0820048025 - 0.025 Cv 0.036 Cv 0 ... 145 psi0820048102 - 0.02 Cv 0.026 Cv 0 ... 116 psi0820048126 - 0.02 Cv 0.026 Cv 0 ... 116 psi

Nominal flow Qn at 87 psi and Δp = 14.5 psi, MO = Manual override

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 155: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 155 | AVENTICS

Technical information

Material

Housing polyphenylene sulfide, Polyamide, fiber-glass reinforced

Seals Acrylonitrile butadiene rubber

Dimensions

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 156: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 156 | AVENTICS

3/2-directional valve, Series DO30- 3/2- Pilot valve width : 30 mm- Plate valve with pipe connection- Compressed air connection output : CNOMO- Electrical connection : Plug, EN 175301-803, form A- Manual override : without detent, with detent- With spring return- suitable for ATEX

Version Poppet valveActivation ElectricallySealing principle Soft sealingStandards CNOMO / NFE 49-003-1Working pressure min./max. 0 ... 145 psiAmbient temperature min./max. 14 ... 122 °FMedium temperature min./max. 14 ... 122 °FMedium Compressed airMax. particle size 5 µmOil content of compressed air 0 ... 5 mg/m³Nominal flow 1 ▶ 2 See table belowNominal flow 2 ▶ 3 See table belowProtection class,with connection IP65Compatibility index 15Duty cycle 100 %Mounting on manifold strip P-stripmounting screws M4Weight 0.132 lbs

Technical data

Part No. MO Compressed air connection Compressed air connectionInput Output

0820019985 CNOMO CNOMO0820019980 CNOMO CNOMO

Part No. Compressed air connection Nominal flow 1 ▶ 2 Nominal flow 2 ▶ 3Exhaust

0820019985 M5 0.069 Cv 0.091 Cv0820019980 M5 0.066 Cv 0.081 Cv

Part No. basic valve with electrical connector ATEX

0820019985 Basic valve without coil suitable for ATEX0820019980 Basic valve without coil suitable for ATEX

Nominal flow Qn at 87 psi and Δp = 14.5 psi, MO = Manual overridepilot valve without coil

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 157: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 157 | AVENTICS

The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 5.4 °F .The oil content of compressed air must remain constant during the life cycle.Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available inthe MediaCentre).

ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coilscatalog page.

Technical information

Technical information

Material

Housing Plastic

Seals Fluorocaoutchouc

Dimensions

Dimensions

t = depth

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 158: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 158 | AVENTICS

Coil, Series CO1- Cable with valve plug connector- Power consumption,DC 3.25 W- Holding power,AC 2.9-3 VA- Switch-on power,AC 3-3.1 VA- ATEX

Certificates ATEXATEX class G II 2G Ex mb IIC T4 GbATEX class D II 2D Ex mb tb IIIC T130°C Db IP65Ambient temperature min./max. -4 ... 122 °FProtection class IP65Duty cycle ED 100 %Compatibility index 14Weight See table below

Technical data

Part No. Operationalvoltage

Operationalvoltage

Operationalvoltage

DC AC 50 Hz AC 60 Hz1827414297 - 230 V 230 V1827414298 - 230 V 230 V1827414299 - 110 V 110 V1827414303 24 V - -1827414304 24 V - -

Part No. Voltage tolerance Voltage tolerance Power consumption Holding powerDC AC 50 Hz DC AC 50 Hz

1827414297 - -10% / +10% - 3 VA1827414298 - -10% / +10% - 3 VA1827414299 - -10% / +10% - 2.9 VA1827414303 -10% / +10% - 3.25 W -1827414304 -10% / +10% - 3.25 W -

Part No. Switch-on power WeightAC 50 Hz

1827414297 3.1 VA 0.838 lbs1827414298 3.1 VA 2.01 lbs1827414299 3 VA 0.838 lbs1827414303 - 0.838 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 159: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 159 | AVENTICS

Part No. Switch-on power WeightAC 50 Hz

1827414304 - 2.01 lbs

Dimensions

Dimensions

L = cable length1) Cable ID band with serial number

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 160: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 160 | AVENTICS

Valve plug connector, series CON-VP- Socket, form C, 2+E, angled, 90°- open cable ends, 3-pin- with cable- unshielded

Ambient temperature min./max. -4 ... 176 °FOperationalvoltage

See table below

Protection class IP67Mounting screw tightening torque 0.3 ft./lbs.Weight See table below

Technical data

Part No. Operationalvoltage

Max. current Protective circuit Contact assignment

1834484213 230 V, AC/DC 6 A - 2+E1834484215 230 V, AC/DC 6 A - 2+E1834484205 24 V, AC/DC 6 A Z-diode 2+E1834484207 24 V, AC/DC 6 A Z-diode 2+E1834484209 230 V, AC/DC 6 A Varistor 2+E1834484211 230 V, AC/DC 6 A Varistor 2+E1834484236 24 V, AC/DC 6 A Z-diode 2+E

Part No. LED status display Number of wires Cable length Weight Fig.

1834484213 - 3 9.84 ft. 0.403 lbs Fig. 2 -1834484215 - 3 16.4 ft. 0.679 lbs Fig. 2 -1834484205 Yellow 3 9.84 ft. 0.408 lbs Fig. 2 1)1834484207 Yellow 3 16.4 ft. 0.657 lbs Fig. 2 1)1834484209 Yellow 3 9.84 ft. 0.428 lbs Fig. 2 1)1834484211 Yellow 3 16.4 ft. 0.628 lbs Fig. 2 1)1834484236 Yellow 3 32.81 ft. 1.26 lbs Fig. 2 1)

1) Scope of delivery incl. flat gasket

The specified protection class is only valid in assembled and tested state.

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 161: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 161 | AVENTICS

Technical information

Material

Seals caoutchouc/butadiene caoutchouc

Cable sheath Polyvinyl chloride

Dimensions

Fig. 1

1) 0° female insert

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 162: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 162 | AVENTICS

DimensionsFig. 2

2) 180° female insert

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 163: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 163 | AVENTICS

Round plug connector, Series CON-RD- Socket, M12x1, 5-pin, A-coded, angled, 90°- open cable ends- for DeviceNet- with cable- unshielded

Ambient temperature min./max. -40 ... 185 °FOperationalvoltage

48 V, AC/DC

Protection class IP65Wire cross-section 0 in²Weight See table below

Technical data

Part No. Max. current Number of wires Cable length Weight

1834484259 4 A 4 9.84 ft. 0.286 lbs1834484260 4 A 4 16.4 ft. 0.445 lbs1834484261 4 A 4 32.81 ft. 0.853 lbs

The specified protection class is only valid in assembled and tested state.

Technical information

Technical information

Material

Cable sheath Polyurethane

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 164: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 164 | AVENTICS

Dimensions

Dimensions

L = length

Pin assignments

Pin assignment socket

(1) BN=brown(2) WH=white(3) BU=blue(4) BK=black(5) not assigned

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 165: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 165 | AVENTICS

Round plug connector, Series CON-RD- Socket, M12x1, 5-pin, A-coded, straight, 180°- open cable ends- with cable- unshielded

Ambient temperature min./max. -13 ... 158 °FOperationalvoltage

48 V, AC/DC

Protection class IP67Wire cross-section 0 in²Weight See table below

Technical data

Part No. Max. current Number of wires Cable length Weight

1834484256 4 A 4 9.84 ft. 0.289 lbs1834484257 4 A 4 16.4 ft. 0.443 lbs1834484258 4 A 4 32.81 ft. 0.877 lbs

The specified protection class is only valid in assembled and tested state.

Technical information

Technical information

Material

Cable sheath Polyurethane

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 166: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 166 | AVENTICS

Dimensions

Dimensions

L = length

Pin assignments

Pin assignment socket

(1) BN=brown(2) WH=white(3) BU=blue(4) BK=black(5) not assigned

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 167: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 167 | AVENTICS

Round plug connector, Series CON-RD- Socket, M12x1, 4-pin, A-coded, straight, 180°- UL (Underwriters Laboratories)- unshielded

Connection type ScrewsAmbient temperature min./max. -40 ... 185 °FOperationalvoltage

48 V, AC/DC

Protection class IP67Weight 0.029 lbs

Technical data

Part No. Max. current

1834484177 4 A

Technical information

Material

Housing Polyamide

Dimensions

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 168: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 168 | AVENTICS

Pin assignments

Pin assignment socket

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 169: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 169 | AVENTICS

Round plug connector, Series CON-RD- Socket, M12x1, 4-pin, A-coded, angled, 90°- unshielded

Connection type ScrewsAmbient temperature min./max. -40 ... 185 °FOperationalvoltage

48 V, AC/DC

Protection class IP67Weight 0.035 lbs

Technical data

Part No. Max. current suitable cable-Ø min./max

1834484178 4 A 0.16 inch

The specified protection class is only valid in assembled and tested state.

Technical information

Technical information

Material

Housing Polyamide

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 170: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 170 | AVENTICS

Dimensions

Dimensions

Pin assignments

Pin assignment socket

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 171: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 171 | AVENTICS

Adapter, Series CON-VP- Socket, form C, 2+E, angled, 90°- Plug, M12x1, 3-pin, A-coded, straight, 180°- unshielded- with LED Yellow

Ambient temperature min./max. 14 ... 212 °FOperationalvoltage

24 V, DC

Protection class IP65Protective circuit VaristorMounting screw tightening torque 0.44 ft./lbs.

Technical data

Part No. Max. current Protective circuit Contact assignment LED status display

R412009553 1 A Varistor 2+E Yellow

Technical information

Material

Housing Polyurethane

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 172: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 172 | AVENTICS

Dimensions

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 173: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 173 | AVENTICS

Transition plate, Series AS1, AS2, AS3,AS5

Weight 0.055 lbs

Technical data

Part No.

R412006360

Scope of delivery incl. 4 mounting screws, 2 O-rings

Adapter plate for assembling a series DO30 pilot valve with CNOMO porting configuration on a 3/2-way shut-off valve without pilot

Technical information

Technical information

Material

Material Aluminum

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 174: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 174 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. A B C D E

R412006360 30 M4 30 21 10

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 175: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 175 | AVENTICS

Adapter- For connection of pneumatic actuation, G 1/8- G 1/8- AS1, AS2, AS3, AS5

Weight 0.042 lbs

Technical data

Part No. Port G

R412006359 G 1/8

Delivery incl. 2 mounting screws M3x20, Flat gasket

Technical information

Material

Material Aluminum

Dimensions

Dimensions

Part No. A B C D E

R412006359 16 26,5 G 1/8 9.7 16

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 176: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 176 | AVENTICS

Adapter for external pilot air

Technical data

Part No.

R412025904

Delivery incl. 1 seal plate, 1 screw 3x10, 1 screw DIN 84-M3x18

Dimensions

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 177: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 177 | AVENTICS

Mounting aid- Assembly aid for permanent actuation of manual override ("press") on pilot valve DO16 withelectrical push-in fitting, form C.

Technical data

Part No.

R412019278

Scope of delivery incl. 1 mounting screw, 1 O-ring

Technical information

Material

Housing Aluminum

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 178: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 178 | AVENTICS

Dimensions

1) ISO 15217, form C

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 179: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 179 | AVENTICS

Mounting aid- Assembly aid for permanent actuation of manual override ("press") on pilot valve DO16 withelectrical connection M12x1.

Weight 0.051 lbs

Technical data

Part No.

R412015193

Mounting the assembly aid to the pilot valve using valve plug connector M12x1

Technical information

Technical information

Material

Housing Aluminum

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 180: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 180 | AVENTICS

Dimensions

1) M12x1

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 181: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 181 | AVENTICS

mortise lock- for AS2, AS3, AS5

Technical data

Part No. Type

R412007959 Standard locking, with keyR412006374 E11 locking, without key

Technical information

Material

Housing Steel

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 182: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 182 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. A B C D E

R412007959 25 13 R10 Ø8 20R412006374 25 13 R10 Ø8 20

Dimensions

Application example

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 183: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 183 | AVENTICS

Key for E11 locking

Technical data

Part No. Delivery unit

R961403407 1 piece

Dimensions

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 184: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 184 | AVENTICS

Pressure sensor, Series PE5- Operating pressure -14.5 ... 0, -14.5 ... 14, 0 ... 87, 0 ... 145, 0 ... 174 psi- electronic- Output signal analog 4 ... 20 mA- Output signal digital 2 outputs, 1 output- IO-Link- Electr. connection Plug, M12x1, 4-pin- Compressed air connection Internal thread, G 1/4

Type electronicCertificates CE declaration of conformity, cULus,

RoHS, Conforms with REACH, Free ofsubstances that impair surface wetting inthe coating process

Compressed air connection Internal thread, G 1/4Ambient temperature min./max. 32 ... 140 °FMedium temperature min./max. 32 ... 140 °FMedium Compressed air (max. 40 μm)Max. oil content of compressed air 40 mg/m³Measurement Relative pressureDisplay LCD display, 4 digits, Color setting: green

or redUnits displayed bar, psi, kPa, MPa, inHgSwitching logic NO/NC (adjustable)Shock resistance max. 30 gVibration resistance 5 g (10 - 150 Hz)Precision (% of full scale value) ±1.5% in temperature range of 10 - 30°C,

± 2 % including temperature driftRepeatability (% of full scale value) ± 0,2 %Switching time 5 msSwitching point adjustable 0 ... 100%Resetting point adjustable 0 ... 100%Hysteresis adjustableDelayed hysteresis adjustableWindow function adjustableDC operating voltage,min./max. 17 ... 30 V DCAnalog output 0 - 10 V DC, 4 - 20 mAQuiescent current consumption 40 mAAnalog output linearity ± 0.5% of the final valueMaximum load (analog current output) 600 ΩShort circuit resistance Max. 600 ohms (current output), Min. 3K

ohms (voltage output)Mounting types Directly on hat rail and wall mounting, For

panel installation using mounting kit, viadouble nipple

Protection class IP65, IP67 with connections assembledElectr. connection Plug, M12x1, 4-pinWeight 0.088 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 185: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 185 | AVENTICS

Technical data

Part No. Operating pressure range Protection against overpressuremin./max.

R412010761 -14.5 ... 0 psi 72.5 psiR412010769 -14.5 ... 0 psi 72.5 psiR412010775 -14.5 ... 0 psi 72.5 psiR412010763 -14.5 ... 14 psi 72.5 psiR412010771 0 ... 87 psi 217.5 psiR412010765 0 ... 87 psi 217.5 psiR412010777 0 ... 87 psi 217.5 psiR412010773 0 ... 145 psi 217.5 psiR412010767 0 ... 145 psi 217.5 psiR412010779 0 ... 145 psi 217.5 psiR412010782 0 ... 174 psi 232 psiR412010806 0 ... 174 psi 232 psi

Part No. Output signal Output signalAnalog digital

R412010761 - 2 outputs-PNP, NPN, Push-pullR412010769 1 output-0 - 10 V DC-4 ... 20 mA 1 output-PNP, NPN, Push-pullR412010775 - 1 output-PNP, NPN, push-pull, 1x IO-LinkR412010763 - 2 outputs-PNP, NPN, Push-pullR412010771 1 output-0 - 10 V DC-4 ... 20 mA 1 output-PNP, NPN, Push-pullR412010765 - 2 outputs-PNP, NPN, Push-pullR412010777 - 1 output-PNP, NPN, push-pull, 1x IO-LinkR412010773 1 output-0 - 10 V DC-4 ... 20 mA 1 output-PNP, NPN, Push-pullR412010767 - 2 outputs-PNP, NPN, Push-pullR412010779 - 1 output-PNP, NPN, push-pull, 1x IO-LinkR412010782 - 2 outputs-PNP, NPN, Push-pullR412010806 - 1 output-PNP, NPN, push-pull, 1x IO-Link

Part No. Fig.

R412010761 Fig. 1R412010769 Fig. 1R412010775 Fig. 1R412010763 Fig. 1R412010771 Fig. 1R412010765 Fig. 1R412010777 Fig. 1R412010773 Fig. 1R412010767 Fig. 1R412010779 Fig. 1R412010782 Fig. 1R412010806 Fig. 1

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 186: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 186 | AVENTICS

Alternative pressure connection (G1/4) on the rear side (closed with plug)Display color selectable, red or greenThe IO-Link device description (IODD) for the PE5 pressure sensor is available for download in the Media Centre.

Technical information

Technical information

Material

Housing Polycarbonate

Seals Acrylonitrile butadiene rubber

Blanking plug Polyoxymethylene

Electr. connection Aluminum, black anodized

Dimensions

Fig. 1

1) M12x1 electrical connection2) Mounting for hat rail and wall mounting

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 187: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 187 | AVENTICS

3) Alternative pressure connection (G1/4) closed with plug4) Pressure connection G1/4

DimensionsFig. 2

1) M12x1 electrical connection2) Mounting for hat rail and wall mounting3) Alternative pressure connection (G1/4) closed with plug4) Pressure connection, tubing Ø 4 mm

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 188: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 188 | AVENTICS

DimensionsDisplay and operation area

1) LCD display2) Control panel with 3 buttons

Diagrams

Operating mode PNP

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 189: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 189 | AVENTICS

DiagramsOperating mode NPN

DiagramsOperating mode Push-pull

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 190: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 190 | AVENTICS

DiagramsHysteresis function: switching and resetting behavior dependent on pressure p and time t In case

H: HysteresisSP = switching pointRP = resetting pointOut (NC): switch output, break contactOut (NO): switch output, make contact

DiagramsHysteresis function: switching and resetting behavior dependent on pressure p and time t In case

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 191: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 191 | AVENTICS

DiagramsDelayed hysteresis function: switching and resetting behavior depending on pressure p and time

H: HysteresisSP = switching pointRP = resetting pointOut (NC): switch output, break contactOut (NO): switch output, make contactdS: switching delaydR = reset delay1) period of pressure over the switching point dS: pressure sensor does not switch2) Period of pressure over the switching point > dS: pressure sensor switches3) Period of pressure under the resetting point > dR: pressure sensor switches

DiagramsWindow function: switching and resetting behavior depending on pressure p and time t

FH: pressure band, upper valueFL: pressure band, lower valueOut (NC): switch output, break contact

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 192: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 192 | AVENTICS

Out (NO): switch output, make contact

Circuit diagram

Block diagram 1x PNP and 1x analog

RL = storable postion

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 193: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 193 | AVENTICS

Circuit diagramBlock diagram 1x NPN and 1x analog

RL = storable postion

Pin assignments

Pin assignments M12x1

operational voltage + UBPin 2: switch output Out2, analog: A or V, digital: PNP, NPN, push-pullPin 3: 0 VPin 4: switch output Out1, digital: PNP, NPN, push-pull

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 194: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 194 | AVENTICS

Pressure sensor, Series PE2- Operating pressure 0 ... 14, 0 ... 232 psi- electronic- Output signal analog 4 ... 20 mA- Output signal digital 1 x PNP, 2 x PNP- Electr. connection Plug, M12x1, 5-pin- Compressed air connection Internal thread, G 1/4, Flange with O-ring, Ø 5x1,5

Type electronicFunction 1 x PNP, 2 x PNP, 1x PNP and 1x analogMounting orientation AnyCertificates CE declaration of conformity, EMVWorking pressure min./max. See table belowAmbient temperature min./max. 14 ... 167 °FMedium temperature min./max. 14 ... 167 °FMedium Compressed air, Neutral gasesMeasurement Relative pressureDisplay OLEDUnits displayed bar, mbar, psi, kPa, MPa, %Switching logic Hysteresis function NO/NC

(programmable), Window function NO/NC(programmable)

Operating pressure display 2 LEDShock resistance max. 30 gVibration resistance 5 g (10 - 150 Hz)Precision (% of full scale value) ± 1 % including temperature driftSwitching time 10 ms at loads 100 kΩ, > 10 ms at loads >

100 kΩSwitching point Adjustable ≥ 0.5% ... 100% FSResetting point Adjustable 0% FS to SP -0.5% FS (or

+0.5% FS when SP 0)Hysteresis adjustableSwitching/reset delay adjustableDC operating voltage,min./max. 15 ... 32 V DCAnalog output 1 x PNP, 1 x analog 4-20 mAQuiescent current consumption 50 mAMaximum load (analog current output) 600 ΩShort circuit resistance short circuit resistantMounting types via through holesProtection class IP65Electr. connection Plug, M12x1, 5-pinWeight 0.661 lbs

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 195: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 195 | AVENTICS

Technical data

Part No. Type Operating pressure rangemin./max.

R412010848 PE2-P1-G014-V10-010-M012 0 ... 14 psiR412010849 PE2-P1-F001-V10-010-M012 0 ... 14 psiR412010853 PE2-P2-G014-V10-010-M012 0 ... 14 psiR412010856 PE2-PA-G014-V10-010-M012 0 ... 14 psiR412010850 PE2-P1-G014-000-160-M012 0 ... 232 psiR412010851 PE2-P1-F001-000-160-M012 0 ... 232 psiR412010854 PE2-P2-G014-000-160-M012 0 ... 232 psiR412010855 PE2-P2-F001-000-160-M012 0 ... 232 psiR412010857 PE2-PA-G014-000-160-M012 0 ... 232 psiR412010858 PE2-PA-F001-000-160-M012 0 ... 232 psi

Part No. Protection against overpressure Output signal Output signal Compressed air connectionAnalog digital

R412010848 145 psi - 1 x PNP Internal thread, G 1/4R412010849 145 psi - 1 x PNP Flange with O-ring, Ø 5x1,5R412010853 145 psi - 2 x PNP Internal thread, G 1/4R412010856 145 psi 4 ... 20 mA 1 x PNP Internal thread, G 1/4R412010850 580 psi - 1 x PNP Internal thread, G 1/4R412010851 580 psi - 1 x PNP Flange with O-ring, Ø 5x1,5R412010854 580 psi - 2 x PNP Internal thread, G 1/4R412010855 580 psi - 2 x PNP Flange with O-ring, Ø 5x1,5R412010857 580 psi 4 ... 20 mA 1 x PNP Internal thread, G 1/4R412010858 580 psi 4 ... 20 mA 1 x PNP Flange with O-ring, Ø 5x1,5

Part No. Fig.

R412010848 Fig. 1R412010849 Fig. 2R412010853 Fig. 1R412010856 Fig. 1R412010850 Fig. 1R412010851 Fig. 2R412010854 Fig. 1R412010855 Fig. 2R412010857 Fig. 1R412010858 Fig. 2

Menu navigation is based on the VDMA specification with an additional plain text menu.

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 196: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 196 | AVENTICS

Technical information

Material

Housing Aluminum, Vibration-ground

Seals Fluorocaoutchouc

Electr. connection Aluminum with polymer insert

At the flange connection: Nitrile butadiene rubber and fluororubber

Dimensions

Fig. 1

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 197: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 197 | AVENTICS

DimensionsFig. 2

1) cylinder screw M5x35 (included in scope of delivery)2) O-ring Ø5x1,5 (included)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 198: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 198 | AVENTICS

DimensionsDisplay and operation area

1) LED for switch output 12) LED for switch output 23) Display (pressure, operating modes, navigation)4) Confirm menu/menu item selection5) Button for menu item/parameter change selection

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 199: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 199 | AVENTICS

Diagrams

Pressure-voltage characteristics curve

SP = switching pointRP = resetting pointNO = Switching function openNC = Switching function closed without currentDS = Delay for the switching pointDR = Delay for the resetting point

Circuit diagram

Block diagram 1 x PNP

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 200: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 200 | AVENTICS

Circuit diagramBlock diagram 2 x PNP

Circuit diagramBlock diagram 1x PNP and 1x analog

Pin assignments

Pin assignments

pin 1: signal + UB, color: brown pin 2: signal: out 2 (PNP)/analog 4 - 20 mA, color: white pin 3: signal: 0 volt, color: blue pin 4: signal:out 1 (PNP), color: black pin 5: signal: FE, color: gray

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 201: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 201 | AVENTICS

Pressure Switches, Series PM1- Operating pressure -13.05 ... 0, -13.05 ... 43, 2.9 ... 232 psi- Mechanical- Spring-loaded bellow, adjustable- Electr. connection Plug, EN 175301-803, form A- Compressed air connection Internal thread, G 1/4, Flange with O-ring, Ø 5x1,5

Type MechanicalFunction change-over contact (mechanical)Mounting orientation AnyWorking pressure min./max. See table belowAmbient temperature min./max. -4 ... 176 °FMedium temperature min./max. 14 ... 176 °FMedium Compressed airMeasurement Relative pressureSwitching element microswitch (input/output)Protection against overpressure 1160 psiMax. switching frequency 1,5 HzShock resistance max. 15 gVibration resistance 10 g (60 - 500 Hz)Repeatability (% of full scale value) ± 1 %Switching point adjustableHysteresis max. switching pressure differenceDC operating voltage,min./max. 12 ... 30 V DCOperational voltage AC,min./max. 12 ... 250 V ACMounting types via through holesProtection class IP65Electr. connection Plug, EN 175301-803, form AWeight 0.353 lbs

Technical data

Part No. Type Operating pressure range Compressed air connectionmin./max.

R412010711 PM1-M3-G014 -13.05 ... 0 psi Internal thread, G 1/4R412022752 PM1-M3-G014 -13.05 ... 43 psi Internal thread, G 1/4R412010712 PM1-M3-G014 2.9 ... 232 psi Internal thread, G 1/4R412010713 PM1-M3-G014 2.9 ... 232 psi Internal thread, G 1/4R412010714 PM1-M3-F001 -13.05 ... 0 psi Flange with O-ring, Ø 5x1,5R412010715 PM1-M3-F001 2.9 ... 232 psi Flange with O-ring, Ø 5x1,5R412010718 PM1-M3-F001 2.9 ... 232 psi Flange with O-ring, Ø 5x1,5

Part No. Scope of delivery Fig.

R412010711 With valve plug connector Fig. 1 -R412022752 Without valve plug connector Fig. 1 -R412010712 Without valve plug connector Fig. 1 1)R412010713 With valve plug connector Fig. 1 1)R412010714 With valve plug connector Fig. 2 -R412010715 Without valve plug connector Fig. 2 1)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 202: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 202 | AVENTICS

Part No. Scope of delivery Fig.

R412010718 With valve plug connector Fig. 2 1)

1) Min. switching pressure range 0.2 bar falling/0.5 bar rising

Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.Notice:Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!The microswitch has silver-plated contacts.Please observe the pin assignment when selecting plug connectors.

Technical information

Technical information

Material

Housing Aluminum

Seals Acrylonitrile butadiene rubber

Electr. connection Brass, nickel-plated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 203: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 203 | AVENTICS

Dimensions

Fig. 1

1) Valve plug connector2) Adjustment screw, self-holding

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 204: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 204 | AVENTICS

DimensionsFig. 2

1) Valve plug connector2) Adjustment screw, self-holding3) cylinder screw M5x30 (included in scope of delivery)4) O-ring Ø5x1,5 (included)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 205: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 205 | AVENTICS

Diagrams

differential switching pressure characteristic curve (-09 – 0 bar)

A) p1 (-), min.B) p1 (-), max.p1 (+) = upper switching pressure with increasing pressurep1 (-) = lower switching pressure with decreasing pressure

Diagramsdifferential switching pressure characteristic curve (02 - 16 bar)

A) p1 (-), min.B) p1 (-), max.p1 (+) = upper switching pressure with increasing pressurep1 (-) = lower switching pressure with decreasing pressureΔ p1 = max. operating pressure difference or hysteresisExample:

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 206: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 206 | AVENTICS

p1 (+) = 8 bar > p1(-) = 7.6 barΔ p1 = 0.4 bar

Diagramsmax. permissible continuous current I max. [A] with ohmic load

U [V] I [A] 1) I [A] 2)

30 5 348 5 1,260 5 0,8

125 5 0,4250 5 –

reference cycle: 30/min., reference temperature: + 30 °C1) AC2) DC

Diagramsmax. permissible continuous current I max. [A] with inductive load

U [V] I [A] 1) 3) I [A] 2) 4)

30 3 248 3 0.5560 3 0.4

125 3 0.15250 3 –

reference cycle: 30/min., reference temperature: + 30 °C1) AC2) DC3) cos ≈ 0,7°4) L/R ≈ 10 ms

Pin assignments

PIN assignment for valve plug connectors

Pin 1 2 3 4

Allocation +UB break contact NO (make contact) GND

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 207: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 207 | AVENTICS

Pressure Switches, Series PM1- Operating pressure -13.05 ... 0, 2.9 ... 232 psi- Mechanical- Spring-loaded bellow, adjustable- Electr. connection Plug, M12x1- Compressed air connection Internal thread, G 1/4, Flange with O-ring, Ø 5x1,5

Type MechanicalFunction change-over contact (mechanical)Mounting orientation AnyWorking pressure min./max. See table belowAmbient temperature min./max. -4 ... 176 °FMedium temperature min./max. 14 ... 176 °FMedium Compressed airMeasurement Relative pressureSwitching element microswitch (input/output)Protection against overpressure 1160 psiMax. switching frequency 1,5 HzShock resistance max. 15 gVibration resistance 10 g (60 - 500 Hz)Repeatability (% of full scale value) ± 1 %Switching point adjustableHysteresis max. switching pressure differenceDC operating voltage,min./max. 12 ... 30 V DCOperational voltage AC,min./max. 12 ... 30 V ACMounting types via through holesProtection class IP67Electr. connection Plug, M12x1Weight 0.331 lbs

Technical data

Part No. Type Operating pressure range Compressed air connectionmin./max.

R412010716 PM1-M3-G014 -13.05 ... 0 psi Internal thread, G 1/4R412010717 PM1-M3-G014 2.9 ... 232 psi Internal thread, G 1/4R412010719 PM1-M3-F001 -13.05 ... 0 psi Flange with O-ring, Ø 5x1,5R412010720 PM1-M3-F001 2.9 ... 232 psi Flange with O-ring, Ø 5x1,5

Part No. Fig.

R412010716 Fig. 1 -R412010717 Fig. 1 1)R412010719 Fig. 2 -R412010720 Fig. 2 1)

1) Min. switching pressure range 0.2 bar falling/0.5 bar rising

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 208: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 208 | AVENTICS

Switching function increasing pressure: contact switches from 1-2 to 1-3.Switching function decreasing pressure: contact switches from 1-3 to 1-2.Notice:Too-high currents can damage contacts. Inductive or capacitive loads must be equipped with appropriate spark-quenching!The microswitch has silver-plated contacts.

Technical information

Technical information

Material

Housing Aluminum

Seals Acrylonitrile butadiene rubber

Electr. connection Brass, nickel-plated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 209: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 209 | AVENTICS

Dimensions

Fig. 1

1) Adjustment screw, self-holding2) Detent position

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 210: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 210 | AVENTICS

DimensionsFig. 2

1) Adjustment screw, self-holding2) cylinder screw M5x30 (included in scope of delivery)3) O-ring Ø5x1,5 (included)4) Detent position

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 211: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 211 | AVENTICS

Diagrams

differential switching pressure characteristic curve (-09 – 0 bar)

A) p1 (-), min.B) p1 (-), max.p1 (+) = upper switching pressure with increasing pressurep1 (-) = lower switching pressure with decreasing pressure

Diagramsdifferential switching pressure characteristic curve (02 - 16 bar)

A) p1 (-), min.B) p1 (-), max.p1 (+) = upper switching pressure with increasing pressurep1 (-) = lower switching pressure with decreasing pressureΔ p1 = max. operating pressure difference or hysteresisExample:

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 212: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 212 | AVENTICS

p1 (+) = 8 bar > p1(-) = 7.6 barΔ p1 = 0.4 bar

Diagramsmax. permissible continuous current I max. [A] with ohmic load

U [V] I [A] 1) I [A] 2)

30-250 3A30 / 48 / 60 / 125 3 / 1,2 / 0,8 / 0,4

reference cycle: 30/min., reference temperature: + 30 °C1) AC2) DC

Diagramsmax. permissible continuous current I max. [A] with inductive load

U [V] I [A] 1) 3) I [A] 2) 4)

30-250 3A30 / 48 / 60 / 125 2 / 0,55 / 0,4 / 0,2

reference cycle: 30/min., reference temperature: + 30 °C1) AC2) DC3) cos ≈ 0,7°4) L/R ≈ 10 ms

Pin assignments

Pin assignments

Pin 1 2 3 4

Allocation +UB break contact No function NO (make contact)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 213: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 213 | AVENTICS

Sensor, Series ST6- 6 mm T-slot- with cable- Plug, M12, 4-pin, with knurled screw- UL certification- Reed- Direct mounting for series PRA, PRE, CCI, KPZ, SSI, GPC, CVI- Indirect mounting for series TRB, ITS, CCL-IS, MNI, CSL-RD, ICM, KHZ, TRR

Certificates CE declaration of conformity, cULus,RoHS

Ambient temperature min./max. -22 ... 176 °FProtection class IP65, IP67Switching point precision ±0,1 mTMin./max. DC operating voltage 10 ... 30 V DCMin./max. AC operating voltage 10 ... 30 V ACHysteresis ≥ 0,2 mTSwitching logic NO (make contact)Switching capacity Reed, 3-pin: max. 6 WLED status display YellowVibration resistance 10 - 55 Hz, 1 mmShock resistance 30 g / 11 ms

Technical data

Part No. for Type of contact Cable lengthL

R412022876 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed 0.984 ft.

Part No. Voltage drop U at Imax DC switching current, max.

R412022876 ≤ 0,1 V 0.3 A

Part No. AC switching current, max. Max. switching frequency

R412022876 0.5 A 400 Hz

Part No. Version

R412022876 Protected against polarity reversal

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 214: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 214 | AVENTICS

Technical information

Material

Housing Polyamide

Cable sheath Polyurethane

Locking screw Stainless steel

Dimensions

Dimensions

1* = switching point 2* = locking screw 3* = LED window, transparentL = cable lengthX = PNP: 11,6 mm, reed: 8,3 mm

Pin assignments

Pin assignments

Pin 1 3 4

Allocation (+) (OUT) (-)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 215: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 215 | AVENTICS

Sensor, Series ST6- 6 mm T-slot- with cable- Plug, M8, 3-pin, with knurled screw- UL certification- Reed- Direct mounting for series PRA, PRE, CCI, KPZ, SSI, GPC, CVI- Indirect mounting for series TRB, ITS, CCL-IS, MNI, CSL-RD, ICM, KHZ, TRR

Certificates CE declaration of conformity, cULus,RoHS

Ambient temperature min./max. -22 ... 176 °FProtection class IP65, IP67Switching point precision ±0,1 mTMin./max. DC operating voltage 10 ... 30 V DCMin./max. AC operating voltage 10 ... 30 V ACHysteresis ≥ 0,2 mTSwitching logic NO (make contact)Switching capacity Reed, 3-pin: max. 6 WLED status display YellowVibration resistance 10 - 55 Hz, 1 mmShock resistance 30 g / 11 ms

Technical data

Part No. for Type of contact Cable sheath

R412022873 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed PolyurethaneR412022875 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed Polyvinyl chlorideR412022874 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed Polyurethane

Part No. Cable lengthL

Voltage drop U at Imax DC switching current, max.

R412022873 0.984 ft. I*Rs 0.3 AR412022875 0.984 ft. I*Rs 0.3 AR412022874 1.64 ft. I*Rs 0.3 A

Part No. AC switching current, max. Max. switching frequency

R412022873 0.5 A 400 HzR412022875 0.5 A 400 HzR412022874 0.5 A 400 Hz

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 216: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 216 | AVENTICS

Part No. Version

R412022873 Protected against polarity reversalR412022875 Protected against polarity reversalR412022874 Protected against polarity reversal

Technical information

Material

Housing Polyamide

Cable sheath Polyurethane, Polyvinyl chloride

Locking screw Stainless steel

Dimensions

Dimensions

1* = switching point 2* = locking screw 3* = LED window, transparentL = cable lengthX = electronic: 11,6 mm, Reed: 8,3 mm

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 217: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 217 | AVENTICS

Pin assignments

Pin assignments

Pin 1 3 4

Allocation (+) (OUT) (-)

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 218: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 218 | AVENTICS

Sensor, Series ST6- 6 mm T-slot- with cable- open cable ends, 3-pin- UL certification- Reed- Direct mounting for series PRA, PRE, CCI, KPZ, SSI, GPC, CVI- Indirect mounting for series TRB, ITS, CCL-IS, MNI, CSL-RD, ICM, KHZ, TRR

Certificates CE declaration of conformity, cULus,RoHS

Ambient temperature min./max. -22 ... 176 °FProtection class IP65, IP67, IP69KSwitching point precision ±0,1 mTMin./max. DC operating voltage 10 ... 30 V DCMin./max. AC operating voltage 10 ... 30 V ACHysteresis ≥ 0,2 mTSwitching logic NO (make contact)Switching capacity Reed, 2-pin: max. 10 W, Reed, 3-pin:

max. 6 WLED status display YellowVibration resistance 10 - 55 Hz, 1 mmShock resistance 30 g / 11 ms

Technical data

Part No. for Type of contact Cable lengthL

R412022869 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed 9.84 ft.R412022870 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed 16.4 ft.R412022871 PRA, PRE, CCI, KPZ, SSI, GPC, CVI Reed 32.81 ft.

Part No. Voltage drop U at Imax DC switching current, max.

R412022869 I*Rs 0.3 AR412022870 ≤ 0,1 V 0.3 AR412022871 I*Rs 0.3 A

Part No. AC switching current, max. Max. switching frequency

R412022869 0.5 A 400 HzR412022870 0.5 A 400 HzR412022871 0.5 A 400 Hz

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 219: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 219 | AVENTICS

Part No. Version Fig.

R412022869 Protected against polarity reversal Fig. 2R412022870 Protected against polarity reversal Fig. 2R412022871 Protected against polarity reversal Fig. 2

open cable ends, 3-pin

No cULus certification for 230 V variant.

Technical information

Technical information

Material

Housing Polyamide

Cable sheath Polyurethane

Locking screw Stainless steel

Dimensions

Fig. 1

1* = switching point 2* = locking screw 3* = LED window, transparentL = cable lengthBN=brown, BU=blue

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 220: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 220 | AVENTICS

DimensionsFig. 2

1* = switching point 2* = locking screw 3* = LED window, transparentL = cable lengthBN = brown, BK = black, BU = blueX = electronic: 11.6 mm

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 221: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 221 | AVENTICS

QR1-S standard series- Straight fitting- External thread- G 1/2- push-in fitting- Ø 8, Ø 10, Ø 12, Ø16, Ø 14- QR1-S-RPN

Working pressure min./max. -13 ... 145 psiAmbient temperature min./max. 32 ... 140 °FWeight See table below

Technical data

Part No. Port G Port D Delivery unit Weight

R412005001 G 1/2 Ø 8 10 piece 0.114 lbs2121010120 G 1/2 Ø 10 10 piece 0.128 lbs2121012120 G 1/2 Ø 12 10 piece 0.125 lbsR412005006 G 1/2 Ø16 10 piece 0.147 lbs2121014120 G 1/2 Ø 14 10 piece 0.141 lbs

The series QR1 (plastic) and QR2 (metal) can not be combinedThread seal with captive O-ring

For further information about assembling and tolerances of adaptable tubing can be found in the “Technical information” document(available in the MediaCentre).

Technical information

Technical information

Material

Material nickel-plated

Housing Brass, nickel-plated

Seal Acrylonitrile butadiene rubber

Tooth lock washer Stainless steel

Release ring Polyoxymethylene

Release ring holder Die cast zinc, Brass, nickel-plated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 222: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 222 | AVENTICS

Material

Thread Brass, nickel-plated

Dimensions

Dimensions

Dimensions

Part No. Port D Port G A B C SW1 SW2 X Y

R412005001 Ø 8 G 1/2 25.7 8.5 18.5 14 6 16 142121010120 Ø 10 G 1/2 27.4 8.5 21 17 8 19 172121012120 Ø 12 G 1/2 29.5 8.5 23 21 10 23 21R412005006 Ø16 G 1/2 36.3 8.5 25.5 24 10 27 242121014120 Ø 14 G 1/2 25.6 8.5 24.6 24 11 25 23

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 223: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 223 | AVENTICS

QR1-S standard series- Elbow fitting- External thread- G 1/2- push-in fitting- Ø 8, Ø 10, Ø 12, Ø 14, Ø16- QR1-S-RVT

Working pressure min./max. -13 ... 145 psiAmbient temperature min./max. 32 ... 140 °FWeight See table below

Technical data

Part No. Port G Port D Delivery unit Weight

R412005093 G 1/2 Ø 8 10 piece 0.108 lbs2122010120 G 1/2 Ø 10 10 piece 0.111 lbs2122012120 G 1/2 Ø 12 10 piece 0.124 lbs2122014120 G 1/2 Ø 14 5 piece 0.146 lbsR412005098 G 1/2 Ø16 5 piece 0.168 lbs

Weight per piece

The series QR1 (plastic) and QR2 (metal) can not be combinedThread seal with captive O-ring

For further information about assembling and tolerances of adaptable tubing can be found in the “Technical information” document(available in the MediaCentre).

Technical information

Technical information

Material

Material nickel-plated

Housing Polybutyleneterephthalate

Seal Acrylonitrile butadiene rubber

Tooth lock washer Stainless steel

Release ring Polyoxymethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 224: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 224 | AVENTICS

Material

Release ring holder Die cast zinc, Brass, nickel-plated

Thread Brass, nickel-plated

Dimensions

Dimensions

Dimensions

Part No. Port D Port G A B C E SW X Y

R412005093 Ø 8 G 1/2 12.5 8.5 18.5 22.6 24 16 142122010120 Ø 10 G 1/2 14.1 8.5 21 27 24 19 142122012120 Ø 12 G 1/2 15.8 8.5 22.5 29.2 24 23 212122014120 Ø 14 G 1/2 17.1 8.5 24.6 32.1 24 25 23R412005098 Ø16 G 1/2 18.2 8.5 24.8 33.3 24 27 24

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 225: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 225 | AVENTICS

Series QR2-S, standard- Straight fitting- External thread- G 1/2- push-in fitting- Ø 12, Ø 14, Ø16- QR2-S-RPN

Working pressure min./max. -13 ... 232 psiAmbient temperature min./max. -4 ... 176 °FWeight See table below

Technical data

Part No. Port G Port D Delivery unit Weight Fig.

1823373054 G 1/2 Ø 12 5 piece 0.106 lbs Fig. 11823373055 G 1/2 Ø 14 5 piece 0.141 lbs Fig. 1R412007955 G 1/2 Ø16 1 piece 0.159 lbs Fig. 1

Weight per piece

The series QR1 (plastic) and QR2 (metal) can not be combinedThread seal with captive O-ring

For further information about assembling and tolerances of adaptable tubing can be found in the “Technical information” document(available in the MediaCentre).

Technical information

Technical information

Material

Housing Brass, nickel-plated

Seal Acrylonitrile butadiene rubber

Tooth lock washer Stainless steel

Release ring Brass, nickel-plated

Thread Brass, nickel-plated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 226: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 226 | AVENTICS

Dimensions

Fig. 1

DimensionsFig. 2

Dimensions

Part No. Port D Port G Ø E H L A* SW 1 SW 2 Fig.

1823373054 Ø 12 G 1/2 24 11 31 20 10 18 Fig. 11823373055 Ø 14 G 1/2 24 11 34 22 12 21 Fig. 1R412007955 Ø16 G 1/2 24 11 37 12 24 - Fig. 1

* Insertion depth

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 227: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 227 | AVENTICS

Series QR2-S, standard- Elbow fitting, rotatable- External thread- G 1/2- push-in fitting- Ø 10, Ø 12, Ø 14, Ø16- QR2-S-RVT

Working pressure min./max. -13 ... 232 psiAmbient temperature min./max. -4 ... 176 °FWeight See table below

Technical data

Part No. Port G Port D Delivery unit Weight

R412007589 G 1/2 Ø 10 5 piece 0.101 lbs1823391840 G 1/2 Ø 12 5 piece 0.143 lbs1823391841 G 1/2 Ø 14 5 piece 0.154 lbsR412007956 G 1/2 Ø16 1 piece 0.185 lbs

Weight per piece

The series QR1 (plastic) and QR2 (metal) can not be combinedThread seal with captive O-ring

For further information about assembling and tolerances of adaptable tubing can be found in the “Technical information” document(available in the MediaCentre).

Technical information

Technical information

Material

Housing Brass, nickel-plated

Seal Acrylonitrile butadiene rubber

Tooth lock washer Stainless steel

Release ring Brass, nickel-plated

Thread Brass, nickel-plated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 228: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 228 | AVENTICS

Dimensions

Dimensions

Part No. Port D Port G ØB ØE H L L1 A* SW

R412007589 Ø 10 G 1/2 15 25 11 30 27 19 161823391840 Ø 12 G 1/2 17 25 11 33.5 28 20 201823391841 Ø 14 G 1/2 20 25 11 33.5 31 22 20R412007956 Ø16 G 1/2 23 25 11 38 33 23.5 20

* Insertion depth

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 229: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 229 | AVENTICS

Series NU2- Swivel banjo connection 1-fold- External thread- G 3/8, G 1/2- plug-in with tube nut- Ø 8, Ø 13- NU2-S-RW1

Working pressure min./max. -13 ... 145 psiAmbient temperature min./max. 14 ... 140 °FWeight See table below

Technical data

Part No. Port G Port D Delivery unit Weight

1823391296 G 3/8 Ø 8 2 piece 0.123 lbsR412007839 G 3/8 Ø 13 2 piece 0.174 lbsR412007838 G 1/2 Ø 13 2 piece 0.216 lbs

Weight per piece

For further information about assembling and tolerances of adaptable tubing can be found in the “Technical information” document(available in the MediaCentre).

Technical information

Technical information

Material

Housing Aluminum, anodized

Seal Polyvinyl chloride

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 230: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 230 | AVENTICS

Dimensions

Dimensions

for fabric-reinforced plastic tubing

Dimensions

Part No. Port D Port G B H L L1 L2 L3 SW1 SW2

1823391296 Ø 8 G 3/8 21 12.5 43 47 35 15.5 22 22R412007839 Ø 13 G 3/8 22.9 12.5 47 49 37 18.5 22 30R412007838 Ø 13 G 1/2 22.9 14 49.5 55 40 18.5 27 30

Connection D = inside diameter of the tubing to be used

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 231: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 231 | AVENTICS

Double nipple, Series PE5- External thread

Weight 0.088 lbs

Technical data

Part No. Port G Port D Delivery unit

R412010015 G 1/4 G 1/8 2 pieceR412010016 G 1/4 G 1/4 2 piece

Dimensions

Dimensions

1) sealing ring Polytetrafluorethylen2) O-ring - acrylonitrile butadiene rubber3) Housing - brass, nickel-plated

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 232: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 232 | AVENTICS

Dimensions

Part No. Port G Port D L1 L2 L3 SW

R412010015 G 1/4 G 1/8 30 10 8.5 17R412010016 G 1/4 G 1/4 30 10 8.5 17

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 233: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 233 | AVENTICS

Blanking screw- External thread- G 1/8, G 1/4- FPT-S-RIO

Working pressure min./max. 0 ... 232 psiAmbient temperature min./max. -4 ... 176 °F

Technical data

Part No. Port G Delivery unit

1823462004 G 1/8 10 piece1823462003 G 1/4 10 piece

Technical information

Material

Material Brass

Dimensions

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 234: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 234 | AVENTICS

Dimensions

Port G ØE L L1 L2 SW1

G 1/8 8 8 5 2 5G 1/4 11 11 7 3.5 6

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 235: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 235 | AVENTICS

plugs

Technical data

Part No. Type Suitable for Delivery unit

R412010124 plugs Pressure gauge connection: G 1/4 10 piece

Technical information

Material

Housing Polyamide

Seal Acrylonitrile butadiene rubber

Dimensions

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 236: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 236 | AVENTICS

Reducing nipple- External thread- G 3/4- Internal thread- G 1/4- FPT-S-RDZ

Working pressure min./max. 0 ... 870 psiAmbient temperature min./max. -4 ... 158 °F

Technical data

Part No. Port G Port D Delivery unit

1823391301 G 3/4 G 1/4 5 piece

Technical information

Material

Material Brass, nickel-plated

Seal Polyvinyl chloride, hard

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 237: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 237 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port D Port G H L1 SW

1823391301 G 1/4 G 3/4 19 7 32

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 238: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 238 | AVENTICS

Sealing ring- Acrylonitrile butadiene styrene

Working pressure min./max. -13 ... 232 psiAmbient temperature min./max. 14 ... 140 °F

Technical data

Part No. Delivery unit

R412010148 10 pieceR412010149 10 pieceR412010150 10 piece

For inserting into the O-ring groove when using series QR1 and QR2 fittings.

Technical information

Material

Material Acrylonitrile butadiene styrene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 239: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 239 | AVENTICS

Dimensions

Dimensions

Part No. usage Type d D s

R412010148 AS2 For compressed air connection G 3/8 17.9 22.5 1.5R412010149 AS3 For compressed air connection G 1/2 22.4 26.4 1.5R412010150 AS5 For compressed air connection G 1 36.9 41.9 1.8

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 240: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 240 | AVENTICS

Silencers, series SI1- Sintered bronze

Working pressure min./max. 0 ... 145 psiAmbient temperature min./max. -13 ... 176 °FMedium Compressed airSound pressure level 85 dBWeight 0.077 lbsComment Flow characteristic curves can be found

under “Diagrams”.

Technical data

Part No. Compressed air connection Flow Delivery unitQn

1827000035 G 1/2 2 Cv 2 piece

Weight per pieceNominal flow Qn at p1 = 87 psi (absolute) freely discharged. Sound pressure level measured at 87 psi against atmosphere at 3.281 ft.distance.

Technical information

Material

Silencers Sintered bronze

Thread Brass

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 241: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 241 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port G L1 L2 SW

1827000035 G 1/2 12 19.5 27

Sound pressure level measured at 6 bar at 1 m distance

Diagrams

Flow diagram 1827000032

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 242: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 242 | AVENTICS

DiagramsFlow diagram 1827000031

DiagramsFlow diagram 1827000033

DiagramsFlow diagram 1827000034

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 243: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 243 | AVENTICS

DiagramsFlow diagram 1827000035

DiagramsFlow diagram 8145003400

DiagramsFlow diagram 8145001000

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 244: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 244 | AVENTICS

Silencers, series SI1- Polyethylene

Working pressure min./max. 0 ... 145 psiAmbient temperature min./max. -13 ... 176 °FMedium Compressed airSound pressure level 88 dBWeight 0.029 lbsComment Flow characteristic curves can be found

under “Diagrams”.

Technical data

Part No. Compressed air connection Flow Delivery unitQn

1827000022 G 1/2 7 Cv 1 piece

Weight per pieceNominal flow Qn at p1 = 87 psi (absolute) freely discharged. Sound pressure level measured at 87 psi against atmosphere at 3.281 ft.distance.

Technical information

Material

Silencers Polyethylene

Thread Polyethylene

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 245: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 245 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port G Ø D L1 L2

1827000022 G 1/2 23.3 66.5 11

Diagrams

Flow diagram 1827000018

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 246: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 246 | AVENTICS

DiagramsFlow diagram 1827000019

DiagramsFlow diagram 1827000020

DiagramsFlow diagram 1827000021

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 247: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 247 | AVENTICS

DiagramsFlow diagram 1827000022

DiagramsFlow diagram 1827000023

DiagramsFlow diagram 1827000024

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 248: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 248 | AVENTICS

Silencers, series SI1- Sintered bronze

Working pressure min./max. 0 ... 145 psiAmbient temperature min./max. -13 ... 176 °FMedium Compressed airSound pressure level 90 dBWeight 0.176 lbsComment Flow characteristic curves can be found

under “Diagrams”.

Technical data

Part No. Compressed air connection Flow Delivery unitQn

1827000003 G 1/2 7.1 Cv 2 piece

Weight per pieceNominal flow Qn at p1 = 87 psi (absolute) freely discharged. Sound pressure level measured at 87 psi against atmosphere at 3.281 ft.distance.

Technical information

Material

Silencers Sintered bronze

Thread Brass

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 249: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 249 | AVENTICS

Dimensions

Dimensions

Dimensions

Part No. Port G SW Ø D L1 L2

1827000003 G 1/2 27 14.5 44 12

Diagrams

Flow diagram 1827000006

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 250: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 250 | AVENTICS

DiagramsFlow diagram 1827000003

DiagramsFlow diagram 1827000004

DiagramsFlow diagram 1827000005

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 251: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 251 | AVENTICS

DiagramsFlow diagram 5324001110

DiagramsFlow diagram 5324001170

DiagramsFlow diagram 5324001120

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 252: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 252 | AVENTICS

DiagramsFlow diagram 5324001140

DiagramsFlow diagram 1827000000

DiagramsFlow diagram R412004817

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 253: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 253 | AVENTICS

DiagramsFlow diagram 1827000001

DiagramsFlow diagram 1827000002

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 254: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 254 | AVENTICS

Series RV1- Qn 1▶2 = 2.67-34.05 Cv- thread-in- External thread- G 3/4- Uncollected

Version Poppet valveCertificates CE declaration of conformityWorking pressure min./max. 0 ... 290 psiOpening pressure of valve See table belowAmbient temperature min./max. -4 ... 212 °FMedium Compressed air

Technical data

Part No. Port 1 Opening pressure of valve FlowQn 1▶2

R412007544 G 3/4 0.5 bar 2.67 CvR412007684 G 3/4 1 bar 3.84 CvR412007545 G 3/4 3.5 bar 8.88 CvR412007546 G 3/4 6 bar 13.91 CvR412007547 G 3/4 6.5 bar 14.99 CvR412007548 G 3/4 8 bar 17.94 CvR412007549 G 3/4 10 bar 21.97 CvR412007550 G 3/4 11 bar 23.98 CvR412007551 G 3/4 12.5 bar 27 CvR412007552 G 3/4 16 bar 34.05 Cv

The specified performance values are achieved at a 10% (PE 14.5 psi , 1.45 psi ) pressure increase, measured with compressed airat 68 °F .

Technical information

PDF creation date: 18.04.2019 LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01

Page 255: Maintenance unit, 2-part, Series AS5- ACD · Page 1 | AVENTICS Maintenance unit, 2-part, Series AS5-ACD - G 3/4, G 1

Page 255 | AVENTICS

Technical information

Material

Housing Brass

Seals Fluorocaoutchouc

Dimensions

Dimensions

G = connection 1

Dimensions

Part No. Port G Ø D H L SW T [Nm] NW

R412007544 G 3/4 32 106 12 30 60 20R412007684 G 3/4 32 106 12 30 60 20R412007545 G 3/4 32 106 12 30 60 20R412007546 G 3/4 32 106 12 30 60 20R412007547 G 3/4 32 106 12 30 60 20R412007548 G 3/4 32 106 12 30 60 20R412007549 G 3/4 32 116 12 30 60 20R412007550 G 3/4 32 116 12 30 60 20R412007551 G 3/4 32 116 12 30 60 20R412007552 G 3/4 32 116 12 30 60 20

T = maximum torqueNW = nominal width