Main Menu Data Output Menu - SHIMADZU CORPORATION · Unit setting menu Calibration menu Zero / tare...

2
Menu Map Sheet For details on the organization of the menu settings and the method of operation of the menu, see "3. MENU SETTINGS" ( ^page 40). Main Menu Data Output Menu STAND POURING WIN| WIN|.U WIN- WIN-.U Z.TRC APL.FUNC TOOLS FORMULA TG.VAL LM.VAL OVR.RNG PARAM.W STB.MK BAND SYSTEM POINT PERIOD COMMA FAST SAMPLE SAMPLE OPTION General weighing mode WindowsDirect communication function Pouring mode Zero tracking function Application function mode Specific percentage reference Formulation Other functions Target value Permissible range Fast Checkweighing range upper limit Stability mark Weighing parameters System Decimal point indication Period Comma Stability detection range PERCENT Percentage weighing PCS Piece counting TARGT Target mode CHECK.W Checkweighing mode 0.5D 1D 10D 50D 100D 1000D Auto power-off HI.LIM Pass range upper limit LO.LIM Pass range lower limit UND.RNG Checkweighing range lower limit Item number ~ 100% reference AUTO.OFF START BAL.ID AUTO SEM.AUTO MANU COND.OUT RESET Start display Balance ID Menu settings output Menu reset Weighing mode OFF display All segments lit Backlight (TXB series only) PASS.WRD Password P.77 P.77 P.111 P.71 P.87 P.92 P.102 P.104 P.79 P.80 P.42 P.138 P.96 P.139 P.69 P.140 P.53 P.51 P.141 BC.LIT Weight display Press [MENU/ENTER]. MODE.5 Standard settings (MODE1 - MODE5) WIN| APL.PRN AUTO.PRN WIN|.U WIN- WIN-.U WindowsDirect communication function Application output Communication settings Auto print function Continuous output function COMM.SET WIN|.U WIN- WIN-.U WIN| WindowsDirect communication function MODE.1 MODE.2 MODE.3 MODE.4 MODE.U Baud rate BPS SEQ.PRN Output timing change function RET. 0 RET.50 Z.RET Zero return judgment Zero or negative value 50% [300] B. 300 [600] B. 600 [1200] B.1200 [2400] B.2400 Parity PARITY [4800] B.4800 [9600] B.9600 [19.2 K] B. 19.2K [38.4 K] B. 38.4K None P.NONE Odd P.ODD Even P.EVEN Delimiter DELIM CR CR LF LF CR+LF CR+LF Comma COMMA Stop bit STOP Handshake HAND.SHK None HS.OFF S. 1 1 bit S. 2 2 bits Hardware HS.HW DF. 1 Data format 1 Timer H.S.TIM Data format D.FORM Data format 2 DF. 2 Data format 3 DF. 3 Head byte D. HEAD Data length D. LEN Data format 4 DF. 4 Free format DF.FRE P.126 P.108 P.129 P.111 P.106 P.127 P.127 P.127 P.127 P.128 P.128 User-specified settings PRINT.F SOON Software HS.SW Weight display Press [PRINT] for 3 sec. LD. . LD.UL. LD. .Z LD.UL.Z LD.OK. On Ld On -Ld On 0Ld On -0Ld On OK MANU Key operation NO.FIL No filter CONV.K MIN.D Minimum indication User-specified units Conversion factors UNIT-U UNIT- UNIT- mg #1 g UNIT- kg #2 UNIT- ct Weight display Press [UNIT] for 3 sec. Other units cannot be selected in some countries due to legal restrictions. #1: mg cannot be selected on models whose minimum indication is 10 mg or greater. #2: kg cannot be selected on the TWC***L and TXC***L. P.85 P.84 P.83 CAL.EXE GLP.OUT GLP output function Calibration P.CAL E.TEST Calibration of the internal weight (TW series only) Calibration check using an external weight I.CAL I.TEST Span calibration using the internal weight (TW series only) E.CAL Span calibration using an external weight Calibration check using the internal weight (TW series only) P.142 P.64 P.57 P.62 P.56 P.60 Weight display Press [CAL] for 3 sec. Z.TRC Zero tracking function A.TARE Auto tare function SOON TARE.F Zero / tare timing change function P.71 P.74 P.72 P.75 Auto zero function A.ZERO Weight display Press [O/T] for 3 sec. Unit setting menu Calibration menu Zero / tare menu 321-56867-21A Sep. 2009 Press or to search for the menu option. Press to return to the previous menu option. (Pressing for around 3 seconds during menu operation returns you to the weighing mode.) Press to proceed to the next menu option. Refers to a page in the instruction manual. Press to confirm. The default settings (settings when the menu is reset)

Transcript of Main Menu Data Output Menu - SHIMADZU CORPORATION · Unit setting menu Calibration menu Zero / tare...

Page 1: Main Menu Data Output Menu - SHIMADZU CORPORATION · Unit setting menu Calibration menu Zero / tare menu 321-56867-21A Sep. 2009 Press or to search for the menu option. Press to return

Menu Map SheetFor details on the organization of the menu settings and the method of operation of the menu, see "3. MENU SETTINGS" (^ page 40).

Main Menu Data Output Menu

STAND

POURING

WIN| WIN|.U WIN- WIN-.U

Z.TRC

APL.FUNC

TOOLS

FORMULA

TG.VAL

LM.VAL

OVR.RNG

PARAM.W STB.MK

BAND

SYSTEM POINT PERIOD

COMMA

FAST

SAMPLE

SAMPLE

OPTION

General weighing mode

WindowsDirect communication function

Pouring mode

Zero tracking function

Application function mode

Specific percentage reference

Formulation

Other functionsTarget value

Permissible range

Fast

Checkweighing range upper limit

Stability markWeighing parameters

System Decimal point indication

Period

Comma

Stability detection range

PERCENTPercentage weighing

PCSPiece counting

TARGTTarget mode

CHECK.WCheckweighing mode

0.5D

1D

10D

50D

100D

1000D

Auto power-off

HI.LIM Pass range upper limit

LO.LIM Pass range lower limit

UND.RNG Checkweighing range lower limit

Item number ~

100% reference

AUTO.OFF

START

BAL.ID

AUTO

SEM.AUTO

MANU

COND.OUT

RESET

Start display

Balance ID

Menu settings output

Menu reset

Weighing mode

OFF display

All segments lit

Backlight(TXB series only)

PASS.WRD Password

P.77

P.77

P.111

P.71

P.87

P.92

P.102

P.104

P.79

P.80

P.42

P.138

P.96

P.139

P.69

P.140

P.53

P.51

P.141

BC.LIT

Weight display

Press[MENU/ENTER].

MODE.5

Standard settings (MODE1 - MODE5)

WIN|

APL.PRN AUTO.PRN

WIN|.U WIN- WIN-.UWindowsDirect communication function

Application output

Communication settings

Auto print function

Continuous output function

COMM.SET

WIN|.U

WIN- WIN-.U

WIN|WindowsDirect communication function

MODE.1

MODE.2

MODE.3

MODE.4

MODE.UBaud rateBPS

SEQ.PRN

Output timing change function

RET. 0

RET.50

Z.RETZero return judgment

Zero or negative value

50%

[300]B. 300[600]B. 600[1200]B.1200[2400]B.2400

ParityPARITY

[4800]B.4800[9600]B.9600[19.2 K]B. 19.2K[38.4 K]B. 38.4K

NoneP.NONEOdd P.ODDEven P.EVEN

DelimiterDELIM CRCR

LFLFCR+LFCR+LFCommaCOMMA

Stop bitSTOP

HandshakeHAND.SHK NoneHS.OFF

S. 1 1 bit

S. 2 2 bits

HardwareHS.HW

DF. 1 Data format 1

TimerH.S.TIM

Data formatD.FORM

Data format 2DF. 2Data format 3DF. 3

Head byteD. HEAD

Data lengthD. LEN

Data format 4DF. 4

Free formatDF.FRE

P.126

P.108

P.129

P.111

P.106

P.127

P.127

P.127

P.127

P.128

P.128

User-specified settings

PRINT.F SOON

SoftwareHS.SW

Weight display

Press [PRINT] for 3 sec.

LD. .

LD.UL.

LD. .Z

LD.UL.Z

LD.OK.

On Ld

On -Ld

On 0Ld

On -0Ld

On OK

MANU Key operation

NO.FIL No filter

CONV.K

MIN.D

Minimum indicationUser-specified units

Conversion factors

UNIT-U

gUNIT-

UNIT-mg #1

g

UNIT-kg #2

UNIT-ct

Weight display

Press [UNIT] for 3 sec.

Other units cannot be selected in some countries due to legal restrictions.#1: mg cannot be selected on models

whose minimum indication is 10 mg or greater.

#2: kg cannot be selected on the TWC***L and TXC***L.

P.85

P.84

P.83 CAL.EXE

GLP.OUT GLP output function

Calibration

P.CAL

E.TEST

Calibration of the internal weight (TW series only)

Calibration check using an external weight

I.CAL

I.TEST

Span calibration using the internal weight (TW series only)

E.CALSpan calibration using an external weight

Calibration check using the internal weight (TW series only)

P.142

P.64

P.57

P.62P.56

P.60

Weight display

Press [CAL] for 3 sec.

Z.TRC Zero tracking function

A.TARE Auto tare function

SOONTARE.FZero / tare timing change function

P.71

P.74

P.72

P.75

Auto zero functionA.ZERO

Weight display

Press [O/T] for 3 sec.

Unit setting menu Calibration menu Zero / tare menu

321-56867-21A Sep. 2009

Press or to search for the menu option.

Press to return to the previous menu option.(Pressing for around 3 seconds during menu operation returns you to the weighing mode.)

Press to proceed to the next menu option.

Refers to a page in the instruction manual.

Press to confirm. The default settings (settings when the menu is reset)

Page 2: Main Menu Data Output Menu - SHIMADZU CORPORATION · Unit setting menu Calibration menu Zero / tare menu 321-56867-21A Sep. 2009 Press or to search for the menu option. Press to return

Display panel

1

b c d e f g h i j l n

2 3 4 5 6 7 8 9 0 a

mk

No. Display Name Description See:

1 Battery symbol Lit when the weight reading is stable. Also lit when the option currently set in menu setting is displayed. ^ P.33

2 Zero tracking symbol Lit when the zero tracking function is set ON. ^ P.71

3 Weight symbol This symbol is lit during calibration. ^ P.57 ^ P.62

4 Easy setting indicator Indicates what level the response and stability are currently set to. ^ P.78

5 Pouring symbol Lit when the pouring mode is set. ^ P.77

6 Formulation symbol Lit during mixing measurement (formulation) operations. ^ P.96

7 Menu lock symbol Lit while the menu is locked. ^ P.52

8 Menu operation key symbol During menu operation, indicates which of the menu operation keys can be used. ^ P.47

No. Display Name Description See:

9 Auto print symbol Lit when the Auto Print function is set. ^ P.108

0 Win symbol Lit when the WindowsDirect communication function has been set. ^ P.112

a Communication symbol Indicates that data is being exchanged with an external device. -

b Comparator symbol When the comparator function (Checkweighing) has been set, indicates the comparison judgment. ^ P.102

c Stability mark Lit when the weight reading is stable. Lit when the option currently set in menu setting is displayed.

^ P.48^ P.79

d Minus symbol Lit when the weight reading is negative. -

e Ready symbolLit during the standby mode (TX series only). Also, during weighing, lit to indicate the ready to weigh status, for example when using the formulation function.

^ P.43^ P.96

f Number symbol Lit when it is possible to enter numerical values. ^ P.49

g Hold symbol Lit when a value that is not the real-time weight reading (for example the indication of the unit weight in piece counting) is displayed.

^ P.90^ P.95

h Net weight symbolIndicates that the weight reading displayed in mixing measurement (formulation) is the net weight of the current component with the weight of the container and prior components. Also indicates that a measuring operation is in progress.

^ P.97

i Gross weight symbolIndicates that the weight reading displayed in mixing measurement (formulation) is the total weight of all of the components of the mixture with the weight of the container subtracted.

^ P.97

j Item number indication Shows the item number in the piece counting mode. ^ P.90

k Inverse triangle symbolWhen this symbol is lit when changing the position of the decimal point in the conversion factor with the user-specified units, numerical values can be entered without a decimal point.

^ P.50

l Piece counting symbol Lit while the piece counting mode is in effect. ^ P.90

mSpecific percentage weighing symbol

Lit when the specific percentage reference has been set for percentage weighing. ^ P.94

n Percentage weighing symbol Lit during percentage weighing. ^ P.95

Operation keysNo. Key Press Once and Release Press and Hold for About 3 Seconds

1 [BREAK] Switches between the operation and standby modes -

2 [CAL] Performs calibration Enters the calibration menu

3 [O/T] Tares the balance (setting it to zero) Opens the zero / tare menu

4 [PRINT] Outputs the weight reading to a peripheral device (printer or PC) Opens the data output menu

Menu operation keysNo. Key Press Once and Release Press and Hold for About 3 Seconds

5 [MENU/ENTER] Displays the main menu Shows the menu displayed last

6 [UNIT]

In the weighing mode: Used to select the unitWhen piece counting: Displays the unit weightWhen performing percentage weighing: Displays the reference weight

•••

In the weighing mode: Opens the unit setting menuWhen piece counting: Used to select the item numberWhen performing percentage weighing: Used to select the percentage reference

•••

7 [FUNC] Switches between the weighing mode and the application function mode Selects the minimum number of displayed digits

8 [Res] The response of the display is increased. -

9 [Stb] The stability of the display is increased. -

Operation Control Panel

7 FUNC8 Res 9 Stb

6 UNIT

7 [FUNC]8 [Res] 9 [Stb]

1BREAK

2CAL

3O/T

4PRINT

1BREAK

2CAL

3O/T

4PRINT

5 [MENU/ENTER]

6 [UNIT]

Operation keys Menu operation keys

Display panel

∗1 With the TXB series, is provided.

∗1