Tim Whole Body Suite
MAGNETOM Symphony, A TimSystem features a uniquetelescopic patient table whichenables a full Field-of-View ofup to 200 cm, without increas-ing total system length. Noadditional table extension isrequired.
The table top has standardlength. For Whole-Body examsthe table simply travels furtherout at the rear side of the mag-net. Table movement to its fullextent can be controlled fromthe operator console.
The large FoV helps in imagingmetastases with sequences suchas TIRM (Turbo InversionRecovery). Whole-Body MRAngiography is possible on theentire volume with iPAT.
Max. scan range of 200 cm
Protocols and programs for
Whole-Body MR Angiographyand metastases detection
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
3/203
MAGNETOM Symphony A Tim System
iPAT Extensions (integrated Parallel Acquisition Techniques)
iPAT2 allows iPAT in 2 directionssimultaneously (phase-encoding direction and 3Ddirection for 3D sequences)
By applying PAT in 2 directionssimultaneously, the effectivePAT factor can be maximized,and PAT applications are
extended.Typical clinical applicationsare MR Angiography orultrafast isotropic T1-weighted3D imaging of the head.
CISS & DESS
Unique Siemens sequencesand protocols
3D DESS
(Double Echo Steady State):
T2/ T1-weighted
Excellent fluid-cartilagedifferentiation in orthopedicimaging
3D CISS
(Constructive Interference inSteady State):
Excellent visualization offine structures such as cranial
nerves High resolution imaging of
inner ear and spine
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
4/204
AutoAlign
Automated alignment of slicepositioning for head examina-tions. This option enables easyand accurate patient follow-up.AutoAlign references the 3DMR brain atlas and automaticallyaligns the slice positions in astandard reproducible way.
Automatic slice planning:no manual adjustments ofslice positioning necessary
Reproducibility: reviews allhead images in the sameposition and orientation
Follow-up: reapplies exactlythe same image position as inprevious examinations(supported by the Phoenixtechnique)
syngo Security
Security package for generalregulatory security rules
The option supports customersto achieve compliance withHIPAA (Health Insurance andAccountability Act).
User authentication
Restricts access to functionsand data through privilegesand permissions
Logs relevant data securityinformation in audit trail
MPPS
DICOM Modality PerformedProcedure Steps (MPPS) allowscommunication of informationabout the examinationsfrom the MR system to aninformation system (such asRIS systems). MPPS enablesprovision of data for billing,documentation and planningpurposes to an informationsystem.
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
5/205
MAGNETOM Symphony A Tim System
Advanced Cardiac
Special sequences and scanprotocols for MR studies of theheart
Morphology Heart andVessel Structure and ValveFunction
Dark-blood sequences using
breath-hold technique Ventricular Function and
Wall Motion
Dynamic CINE TrueFISPimaging of cardiac functionwith prospective andretrospective ECG triggering,with or without breath-holdtechnique
Cine imaging with echosharing for high temporalresolution
Triggered retrogated cine
imaging with arrythmiarejection for automaticadjustment of the number ofphases to the heart rate
Real-time cine TrueFISPimaging without need for ECGtriggering or breath-holdcommands
Real-time radial imagingfor high speed and highresolution cine studies
Visualization of myocardialcontractility using varioustagging techniques
Tissue characterization(differentiation of tissues withdifferent T1 values)
Ultrafast, high SNR sequencesfor first pass imaging usingTrueFISP iPAT and Half Fouriertechniques. These protocolsprovide multi-slice informationfor the assessment of coronaryheart disease (TrueFISP)
Robust and reproduciblecontrast between infarct andnormal myocardium withphase-sensitive Inversionrecovery. Adjustment of TI isno longer necessary with thistechnique
Protocols for pediatrics, plaqueimaging and stress imaging
Coronary Imaging
Dedicated sequences forcoronary imaging andangiography providing free
breathing navigator (1D PACE)and breath-hold techniques(2D and 3D FLASH andTrueFISP)
Requires PMU Wireless Physio Control option
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
6/206
Flow Quantification
Special sequences forquantitative flow determinationstudies
Measuring blood/CSF flownon-invasively
Requires PhysiologicalMeasurement Unit (PMU) option
RetroGated Flow
Dynamic representation oftemporally changing flow
Interactive Realtime
Sequences and hardware forinteractive real-time scanning.
Uses ultrafast TrueFISP andother Gradient Echo sequencesfor high image contrast
Real-time reconstruction of theacquired data
The user can navigate in allplanes on-the-fly during dataacquisition
Real-time cardiacexaminations
Real-time interactiveslice positioning and sliceangulation
3D Magellan SpaceMouseincluded
TGSE (Turbo Gradient Spin Echo)
Ultrafast sequence providinghigh resolution imaging orextremely short acquisition
times
Hybrid Turbo Spin Echo/Gradient Echo used primarilyfor T2-weighted imaging
Shorter measurement time
Decreased RF powerdeposition
Improved visualization ofhemorrhage, due to magneticsusceptibility differences
High resolution imaging ofbrain and spine
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
7/20
MAGNETOM Symphony A Tim System
7
Inline Diffusion
Automatic real-time calculationof trace-weighted images andADC maps with Inline Technol-ogy. Compatible with single-shot diffusion weighted EPI
Inline Perfusion
Automatic real-time calculationof Global Bolus Plot (GBP),Percentage of Baseline atPeak map (PBP) and Time-to-Peak map (TTP) with Inlinetechnology
Inline BOLD Imaging
(Blood Oxygen Level Dependent)
Examination of intrinsicsusceptibility changes indifferent areas of the brain,induced by external stimulation(e.g. motor or visual)
Automatic real-time calculationof z-score (t-test) maps withInline technology, for variableparadigms
Compatible with single-shotEPI with high susceptibility
contrast for fast multi-sliceimaging
ART (Advanced RetrospectiveTechnique) for fully automatic3D retrospective motioncorrection, for 6 degrees offreedom (3 translations and3 rotations)
Mosaic images for efficientstorage and transfer of largedata sets
3D spatial filtering
Overlay of Inline calculatedt-test results on the EPI images
100
0
0 69.0 S
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
8/208
Advanced Functional Neuro
3D PACE (ProspectiveAcquisition CorrEction)
Prospective motion detectionand correction in the volumeto eliminate motion artifactsduring BOLD measurements
Fully automatic 3D prospectivemotion correction during data
acquisition, for 6 degrees offreedom (3 translations and3 rotations)
Motion correction coveringthe complete 3D volume
Provides high accuracy
Substantially reducedmotion-related artifacts int-test calculations
Significantly increasedsignal changes in the activatedneuronal volume
Increased functionalMRI (fMRI) sensitivity andspecificity
3D Inline fMRI
This specialized task cardemploys volume rendering andcut plane techniques to visualizeresults of BOLD imaging exami-nations overlayed on anatomical3D data sets. Volumes of inter-est can be interactively specifiedto plot their signal time course
over the underlying BOLD scans.Results can be stored andfilmed. During ongoing scansresults are displayed in realtime.
This 3D display of the resultsof functional brain mappingexaminations gives a betterunderstanding of the locationof functional activation withregard to cortical landmarksor brain lesions (e.g. tumors)
Multi-Directional DiffusionWeighted Imaging (DWI)
Measurements of multiple
diffusion directions andb-values
Suitable for investigation ofanisotropic diffusion in tissuesuch as calculation of diffusiontensors
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
9/209
MAGNETOM Symphony A Tim System
Single Voxel Spectroscopy
Integrated software packagewith sequences and protocolsfor proton spectroscopy
Streamlined for easypush-button operation
Matrix Spectroscopy phase-coherent signal combi-nation for maximum SNR
SVS techniques SE and STEAM
Short TEs available
Fully automated adjustmentsincluding localized shimmingand adjustment of watersuppression pulses
Also available:Interactive adjustments and
control of adjustments
Optimized protocols for brainapplications
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
10/2010
Chemical Shift Imaging
Integrated software packagewith sequences and protocolsfor chemical shift imaging (CSI)
Extension of the SVSpackage, offering the samelevel of user-friendliness andautomation
Matrix Spectroscopy
phase-coherent signalcombination for maximumSNR with configurableprescan-based normalizationfor optimal homgeneity
2D and 3D Chemical ShiftImaging
Hybrid CSI with combinedVoIume selection and Fieldof View (FoV) encoding
Short TEs available(30 ms for SE, 20 ms forSTEAM)
Automized shimming ofthe higher order shimmingchannels for optimalhomogeneity of the largerCSI volumes
Weighted acquisition, leadingto a reduced examination timecompared to full k-spacecoverage while keeping SNRand spatial resolution
Outer Volume Suppression
Spectral Suppression
Protocols for prostatespectroscopy
Advanced High Order Shim Option required.
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
11/2011
MAGNETOM Symphony A Tim System
Breast Biopsy Software
Easy to use syngo-basedpost-processing software helpsfinding the coordinates forneedle insertion for biopsy orlocalization of breast lesions
Allows calculation of the coor-dinates after clicking the centerof the lesion and the 0 marker of
the breast biopsy device Printout of working sheet
Multi-lesion calculation
Prerequisites:
Breast Biopsy Device
Loop Flex coil, large
IDEA Integrated Development Environment for Applications
Extensive programmingenvironment used to createand modify pulse sequences,offering a maximum offlexibility
Based on C++ for Windows XP
Sequences and RF pulses aredisplayed in a visual interface
Allows direct accessto the Image CalculationEnvironment (ICE), andto all protocols
Testing the generated code isextensively supported by thedebugger and the simulationprogram
IDEA is also usable on anystan-dard PC with operatingsystem Windows XP makingdevelopments independent ofthe MR system
Processing Plug-ins
For development ormodification of user-definedimage processing steps whichmay be integrated into themeasurement protocols
Individual processing issecured by a number offunctions (e.g. TTP and MTT),useful for neuro or perfusionimaging
Prerequisite:
IDEA training course
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
12/20
On account of certain regional limitations of sales rights
and service availability, we cannot guarantee that all
products included in this brochure are available throughthe Siemens sales organization worldwide. Availability and
packaging may vary by country and is subject to change
without prior notice.
The information in this document contains general
technical descriptions of specifications and options as well
as standard and optional features which do not always have
to be present in individual cases.
Siemens reserves the right to modify the design,
packaging, specifications and options described herein
without prior notice. Please contact your local Siemens
sales representative for the most current information.
Note: Any technical data contained in this document may
vary within defined tolerances. Original images always lose
a certain amount of detail when reproduced.
Please find fitting accessories:
www.siemens.com/medical-accessories
Siemens AG
Wittelsbacherplatz 2
D-80333 Muenchen
Germany
Headquarters
Siemens AG, Medical Solutions
Henkestr. 127, D-91052 Erlangen
Germany
Telephone: +49 9131 84-0
www.siemens.com/medical
Contact
In the USA
Siemens Medical Solutions USA, Inc.
51 Valley Stream Parkway
Malvern, PA 19355
Telephone: +1 888-826-9702
Telephone: +1 610-448-4500
Telefax: +1 610-448-2254
In Japan
Siemens-Asahi
Medical Technologies Ltd.
Takanawa Park Tower 14F
20-14, Higashi-Gotanda 3-chome
Shinagawa-ku
Tokyo 141-8644
Telephone: +81 3 5423 8411
In AsiaSiemens Medical Solutions
Asia Pacific Headquarters
The Siemens Center
60 MacPherson Road
Singapore 348615
Telephone: +65 6490 6000
Telefax: +65 6490 6001
In Germany
Siemens AG, Medical Solutions
Magnetic Resonance
Henkestr. 127, D-91052 Erlangen
Germany
Telephone: +49 9131 84-0
06.2005, Siemens AG
Order No. A91001-M2220-G13-E3-7600
Printed in Germany
PA 06053.5
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
13/20
Data
MAGNETOM Symphony, A Tim SystemPost-processing Packages
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
14/202
All post-processing packagesare separately available for theMR Main Console (MRC) orMR Satellite Console (MRSC)
Image Filter
For noise reduction in theMR images and better edgedefinition
Uses high-pass and low-passfiltering
Automatically adjusts to thelocal image content (adaptivefiltering)
Argus Function
Automated tool for cardiacfunction evaluation
Fully automatic imagesegmentation
Easy user guidance withgraphical selection of ED, ES,basal and apical slices
Global function and regionalwall motion analysis with colorresults
Argus Flow
Automated tool for analysis ofblood and CSF flow
Semi-automatic detection of
regions of interest over time Color-coded display of velocity
values
Calculation of flow andvelocity parameters with colorresults
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
15/203
MAGNETOM Symphony A Tim System
Argus Dynamic Signal
Automated tool for dynamicdata analysis
Manual or automaticsegmentation
Automatic compensationof contours in regard totranslation or deformationof organs over time
Sector-based or ROI-basedevaluation
Evaluation of Time-to-Peak,Peak Value, Uptake Slope,Area under the Curve
Graphical display of results inparameterized bulls eye plots
Vessel View
Interactive analysis ofvessel disease using MR orCT angiography data
Viewing with VRT, MPR orMIP mode
Automatic or semi-automaticdetection of vessel segments
Quantification of changesin vessel size
Protocol-based softwarefor workflow support
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
16/204
3D VRT Volume Rendering Technique
3D visualization for clearerdepiction of complex anatomyand relationship of anatomy in3D for contrast MR Angiographyand VIBE imaging
More productive surgicalplanning and discussion withreferring physicians
Integrated with other 3Dfunctionality
Color image creation
Color gallery of icon presets
Additional threshold-basedsegmentation of 3D objects
Volume measurements
Image Fusion
Image fusion of multiple 3Ddata sets with alpha blending,i.e. overlay of two images withmanual setting of the opacity
Multiple 3D data sets fromdifferent modalities (MR, CT,Nuclear Medicine, PET)
Visual alignment, automaticregistration, or landmarkbased registration
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
17/205
MAGNETOM Symphony A Tim System
Neuro Perfusion Evaluation
Dedicated task card forquantitative processing ofneuro perfusion data
Color display of relativeMean Transit Time (relMTT),relative Cerebral Blood Volume(relCBV), and relative CerebralBlood Flow (relCBF)
Flexible selection ofArterial Input Function (AIF)for reliable analysis. Thisfunction takes into accountthe dynamics over time of thecontrast agent enhancement.
BOLD Evaluation
(Blood Oxygen Level Dependent)
Dedicated task card foradvanced post-processingof BOLD data sets
Offline calculation of t-testmaps from original fMRI data,e.g. with different filtersettings as in the Inlinecalculation
Colored overlay of functionaland anatomic data
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
18/206
3D Offline fMRI (only for MRSC)
This dedicated task card employsvolume rendering and cut planetechniques to visualize resultsof BOLD imaging examinationsoverlayed on anatomical 3D datasets. Volumes of interest can beinteractively specified to plottheir signal time course over theunderlying BOLD scans. Results
can be stored and filmed
The 3D display of the results offunctional brain mappingexaminations gives a betterunderstanding of the locationof functional activation withregard to cortical landmarks orbrain lesions (e.g. tumors)
Spectroscopy Evaluation
Integrated software packagewith extensive graphical displayfunctionality
Comprehensive anduser-friendly evaluation ofspectroscopy data
Display of CSI data as coloredmetabolite images or spectraloverview maps, overlayed onanatomical images
Export of spectroscopy data to
a user-accessible file format Relative quantification of
spectra, compilation of thedata to result table
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
19/207
MAGNETOM Symphony A Tim System
Spine Composing
Composing of images for spineexaminations
Automatic and manualcomposing of Whole Spineimages
Measurement on composedimages (angle, distance)
-
8/14/2019 MAGNETOM Symphony Tim Appl Packs
20/20
On account of certain regional limitations of sales rights
and service availability, we cannot guarantee that all
products included in this brochure are available throughthe Siemens sales organization worldwide. Availability and
packaging may vary by country and is subject to change
without prior notice.
The information in this document contains general
technical descriptions of specifications and options as well
as standard and optional features which do not always have
to be present in individual cases.
Siemens reserves the right to modify the design,
packaging, specifications and options described herein
without prior notice. Please contact your local Siemens
sales representative for the most current information.
Note: Any technical data contained in this document may
vary within defined tolerances. Original images always lose
a certain amount of detail when reproduced.
Please find fitting accessories:
www.siemens.com/medical-accessories
Siemens AG
Wittelsbacherplatz 2
D-80333 Muenchen
Germany
Headquarters
Siemens AG, Medical Solutions
Henkestr. 127, D-91052 Erlangen
Germany
T l h 49 9131 84 0
Contact
In the USA
Siemens Medical Solutions USA, Inc.
51 Valley Stream Parkway
Malvern, PA 19355
Telephone: +1 888-826-9702
Telephone: +1 610-448-4500
Telefax: +1 610-448-2254
In Japan
Siemens-Asahi
Medical Technologies Ltd.
Takanawa Park Tower 14F
20-14, Higashi-Gotanda 3-chome
Shinagawa-ku
Tokyo 141-8644
Telephone: +81 3 5423 8411
In AsiaSiemens Medical Solutions
Asia Pacific Headquarters
The Siemens Center
60 MacPherson Road
Singapore 348615
Telephone: +65 6490 6000
Telefax: +65 6490 6001
In Germany
Siemens AG, Medical Solutions
Magnetic Resonance
Henkestr. 127, D-91052 Erlangen
G
06.2005, Siemens AG
Order No A91001-M2220-G13-F3-7600