Magnetic Resonance Imaging

27
Magnetic Resonance Imaging Maurice Goldman Member Académie des sciences

description

Magnetic Resonance Imaging. Maurice Goldman Member Académie des sciences. History of MRI. MRI was born in 1973. The parents: Paul Lauterbur (then at Stony Brooks), Sir Peter Mansfield (Nottingham, not yet Sir at the time) were awarded the Nobel Prize in Physiology or Medicine in 2003. - PowerPoint PPT Presentation

Transcript of Magnetic Resonance Imaging

Page 1: Magnetic Resonance Imaging

Magnetic Resonance Imaging

Maurice GoldmanMember Académie des sciences

Page 2: Magnetic Resonance Imaging

History of MRI

• MRI was born in 1973.

The parents:

• Paul Lauterbur (then at Stony Brooks),

• Sir Peter Mansfield (Nottingham, not yet Sir at the time)

were awarded the Nobel Prize in Physiology or Medicine in 2003.

Page 3: Magnetic Resonance Imaging

The principle

• The imaging is that of liquid samples, essentially water protons in living organisms (for medical MRI).

• If the (supposedly linear) sample is subjected to a field gradient, the position is coded by it is resonance frequency, and that’s all!

• If the sample is not linear, the problem gets more involved.

Page 4: Magnetic Resonance Imaging

Paul Lauterbur (Gordon Conference, spring 1973)

1- Excite a 2D slice by a rf pulse in a field gradient along Oz,

2-Apply a gradient along a perpendicular direction and look at the frequency dependence of the NMR signal,

3- Repeat at various orientations of the gradient,4- Deduce the 2D image by Back-Projection.5- Iterate as many times as necessary.

Dubbed “Zeugmatography”

Page 5: Magnetic Resonance Imaging

G

Strips selected by a given gradient direction

• The signal amplitude at each frequency is due to the cumulative contribution of the spins in adjacent sample strips

Page 6: Magnetic Resonance Imaging

Back Projection

-Assume uniform contribution along each strip.

Superposing these strip amplitudes for different orientations, yields the amplitudes for each pixel.

These are used for iteration.

Same approach as in CT scanner

Page 7: Magnetic Resonance Imaging

Peter Mansfield(Ampere summer school, Cracow, fall 1973)

Gives a lecture on

“NMR diffraction from static spins”, based essentially on the same idea of using field gradients, but initially thought to be able to resolve structures at the atomic level.

Recognizes that a more modest ambition on liquid samples might be easier to reach.

Page 8: Magnetic Resonance Imaging

Most common practice:Phase encoding

Kumar, Welti and Ernst (1975):same as 2D spectroscopy

• Slice selection with gradient Gz,• Blind phase encoding with gradient Gy during

time ,• Sampling with gradient Gx during time t• Repeat for various durations .

Drawback: relaxation during .

Page 9: Magnetic Resonance Imaging

Better sequence

Edelstein, Hutchison et al (1980):

Use always the same duration , but vary the amplitude of the gradient Gy.

Page 10: Magnetic Resonance Imaging

Schematic sequence

Page 11: Magnetic Resonance Imaging

Rationale of imaging

Page 12: Magnetic Resonance Imaging
Page 13: Magnetic Resonance Imaging

The strategy for imaging:

Perform an adequate filling of the reciprocal space and Fourier-

transform it.

That’s all, folks!

The gospel of MRI

Page 14: Magnetic Resonance Imaging

Filtered Back-ProjectionFourier transform in polar coordinates

Page 15: Magnetic Resonance Imaging

Phase encodingFourier transform in normal coordinates (FFT)

Page 16: Magnetic Resonance Imaging

Contrast production

Contrast agents

•Superparamagnetic particles•Gadolinium chelates

Page 17: Magnetic Resonance Imaging

Improvements

• Selective excitation by sinc pulse:

Sinc(x)=sin(x)/x

• Produce gradient echo to observe signal,

• Refocus magnetization to increase S/N,

• Series of specialized sequences for specific applications,

• Improved gradients, etc.

Page 18: Magnetic Resonance Imaging

Ex : True FISP sequence

Page 19: Magnetic Resonance Imaging

Ex : MARYSE Sequence

Page 20: Magnetic Resonance Imaging

Other measurements

• Flow :

phase imaging or presaturation of fov.

• Diffusion tensor:

bouncing on cell walls modifies apparent diffusion coefficient

Page 21: Magnetic Resonance Imaging

Single-shot sequences for fast imagingEx: Echo Planar Imaging (30 to 50 ms)

(P. Mansfield 1978)

Page 22: Magnetic Resonance Imaging

Various codings of reciprocal space

Page 23: Magnetic Resonance Imaging

Functional MRI (fMRI)

• Hemoglobin is diamagnetic

• Deoxyhemoglobin is paramagnetic. It decreases locally the relaxation times

• Images are obtained by difference

Page 24: Magnetic Resonance Imaging

Lauterbur (1973)two capillaries of water

Page 25: Magnetic Resonance Imaging

Mansfield, Maudsley (1977)cross section of finger

Page 26: Magnetic Resonance Imaging

Edelstein, Hutchison et al. (1980)chest (slice thickness 18.5 mm)

Page 27: Magnetic Resonance Imaging

My radiologist (2008)head and brain (slice thickness sub mm )