Nuclear Magnetic Resonance (NMR) Magnetic Resonance Imaging (MRI)
Magnetic Resonance Imaging
description
Transcript of Magnetic Resonance Imaging
![Page 1: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/1.jpg)
Magnetic Resonance Imaging
Maurice GoldmanMember Académie des sciences
![Page 2: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/2.jpg)
History of MRI
• MRI was born in 1973.
The parents:
• Paul Lauterbur (then at Stony Brooks),
• Sir Peter Mansfield (Nottingham, not yet Sir at the time)
were awarded the Nobel Prize in Physiology or Medicine in 2003.
![Page 3: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/3.jpg)
The principle
• The imaging is that of liquid samples, essentially water protons in living organisms (for medical MRI).
• If the (supposedly linear) sample is subjected to a field gradient, the position is coded by it is resonance frequency, and that’s all!
• If the sample is not linear, the problem gets more involved.
![Page 4: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/4.jpg)
Paul Lauterbur (Gordon Conference, spring 1973)
1- Excite a 2D slice by a rf pulse in a field gradient along Oz,
2-Apply a gradient along a perpendicular direction and look at the frequency dependence of the NMR signal,
3- Repeat at various orientations of the gradient,4- Deduce the 2D image by Back-Projection.5- Iterate as many times as necessary.
Dubbed “Zeugmatography”
![Page 5: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/5.jpg)
G
Strips selected by a given gradient direction
• The signal amplitude at each frequency is due to the cumulative contribution of the spins in adjacent sample strips
![Page 6: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/6.jpg)
Back Projection
-Assume uniform contribution along each strip.
Superposing these strip amplitudes for different orientations, yields the amplitudes for each pixel.
These are used for iteration.
Same approach as in CT scanner
![Page 7: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/7.jpg)
Peter Mansfield(Ampere summer school, Cracow, fall 1973)
Gives a lecture on
“NMR diffraction from static spins”, based essentially on the same idea of using field gradients, but initially thought to be able to resolve structures at the atomic level.
Recognizes that a more modest ambition on liquid samples might be easier to reach.
![Page 8: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/8.jpg)
Most common practice:Phase encoding
Kumar, Welti and Ernst (1975):same as 2D spectroscopy
• Slice selection with gradient Gz,• Blind phase encoding with gradient Gy during
time ,• Sampling with gradient Gx during time t• Repeat for various durations .
Drawback: relaxation during .
![Page 9: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/9.jpg)
Better sequence
Edelstein, Hutchison et al (1980):
Use always the same duration , but vary the amplitude of the gradient Gy.
![Page 10: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/10.jpg)
Schematic sequence
![Page 11: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/11.jpg)
Rationale of imaging
![Page 12: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/12.jpg)
![Page 13: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/13.jpg)
The strategy for imaging:
Perform an adequate filling of the reciprocal space and Fourier-
transform it.
That’s all, folks!
The gospel of MRI
![Page 14: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/14.jpg)
Filtered Back-ProjectionFourier transform in polar coordinates
![Page 15: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/15.jpg)
Phase encodingFourier transform in normal coordinates (FFT)
![Page 16: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/16.jpg)
Contrast production
Contrast agents
•Superparamagnetic particles•Gadolinium chelates
![Page 17: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/17.jpg)
Improvements
• Selective excitation by sinc pulse:
Sinc(x)=sin(x)/x
• Produce gradient echo to observe signal,
• Refocus magnetization to increase S/N,
• Series of specialized sequences for specific applications,
• Improved gradients, etc.
![Page 18: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/18.jpg)
Ex : True FISP sequence
![Page 19: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/19.jpg)
Ex : MARYSE Sequence
![Page 20: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/20.jpg)
Other measurements
• Flow :
phase imaging or presaturation of fov.
• Diffusion tensor:
bouncing on cell walls modifies apparent diffusion coefficient
![Page 21: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/21.jpg)
Single-shot sequences for fast imagingEx: Echo Planar Imaging (30 to 50 ms)
(P. Mansfield 1978)
![Page 22: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/22.jpg)
Various codings of reciprocal space
![Page 23: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/23.jpg)
Functional MRI (fMRI)
• Hemoglobin is diamagnetic
• Deoxyhemoglobin is paramagnetic. It decreases locally the relaxation times
• Images are obtained by difference
![Page 24: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/24.jpg)
Lauterbur (1973)two capillaries of water
![Page 25: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/25.jpg)
Mansfield, Maudsley (1977)cross section of finger
![Page 26: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/26.jpg)
Edelstein, Hutchison et al. (1980)chest (slice thickness 18.5 mm)
![Page 27: Magnetic Resonance Imaging](https://reader035.fdocuments.net/reader035/viewer/2022062217/56814876550346895db5801c/html5/thumbnails/27.jpg)
My radiologist (2008)head and brain (slice thickness sub mm )