Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL...

36
HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position Sensor

Transcript of Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL...

Page 1: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

STEM s.r.l.Sede Legale, Uffici e Stabilimento:

27010 Cura Carpignano PaviaVia della Meccanica, 2Zona Industriale Prado

ITALYTel. +39 0382.583011Fax +39 0382.583058e-mail: [email protected]://www.stemsrl.it

TCP

Pavi

a - e

d. 1

1/13

HALL EffectSensors

Magnetic Hall-Effect SwitchesMagnetic Hall-Effect Linear Position Sensor

Page 2: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

INDICE / INDEXSensori ad effetto hall / Hall effect sensors

Assi di attivazione dei sensori ad effetto hallHall effect sensors activation axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pag.3

Sensore Magnetico Lineare ad Effetto HALLCylindrical Magnetic Linear Hall-Effect Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E53H . . . . . . . . . .Pag.5

Sensore Cilindrico diam. 8 in PPS neroCylindrical uninflammable PPS Black body sensor diam. 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A08H . . . . . . . . . .Pag.8

Sensore semifilettato M12x1 nylon vetro autoestinguenteHalf-Threaded M12x1 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C12H . . . . . . . . . .Pag.9

Sensore cilindrico diam.12 nylon vetro autoestinguenteCylindrical diam.12 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C15H . . . . . . . . . .Pag.10

Sensore filettato M12x1 nylon vetro autoestinguenteThreaded M12x1 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C19H . . . . . . . . . .Pag.11

Sensore filettato M8x0,75 nylon vetro autoestinguenteThreaded M8x0,75 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D08P . . . . . . . . . .Pag.12

Sensore filettato M10x0,75 nylon vetro autoestinguenteThreaded M10x0,75 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D10P . . . . . . . . . .Pag.13

Sensore filettato M12x1 nylon vetro autoestinguenteThreaded M12x1 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D12P . . . . . . . . . .Pag.14

Sensore Cilindrico filettato M10x1 in ottone nichelatoCylindrical Threaded M10x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D101 . . . . . . . . . .Pag.15

Sensore Cilindrico filettato M12x1 in ottone nichelatoCylindrical Threaded M12x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D123 . . . . . . . . . .Pag.16

Sensore Cilindrico filettato M12x1 in ottone nichelatoCylindrical Threaded M12x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D125 . . . . . . . . . .Pag.17

Sensore Cilindrico filettato M12x1 in ottone nichelato con connettoreCylindrical Threaded M12x1 nickel-brass sensor with connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D125 . . . . . . . . . .Pag.18

Sensore Cilindrico filettato M12x1 in ottone nichelatoCylindrical Threaded M12x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D128 . . . . . . . . . .Pag.19

Sensore Cilindrico filettato M12x1 in ottone nichelato per Ruote DentateCylindrical Threaded M12x1 Gear Tooth nickel-brass Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D16H . . . . . . . . . .Pag.20

Sensore rettangolare nylon vetro autoestinguente 36 x 13Rectangular uninflammable nylon glass body sensor 36 x 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E512 . . . . . . . . . .Pag.21

Sensore rettangolare nylon vetro autoestinguente 36 x 13 con attivazione centraleRectangular uninflammable nylon glass body sensor 36 x 13 with central activation . . . . . . . . . . . . . . . . . . . . . . . . . . . .E514 . . . . . . . . . .Pag.22

Sensore rettangolare nylon vetro autoestinguente 40 x 13Rectangular uninflammable nylon glass body sensor 40 x 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E522 . . . . . . . . . .Pag.23

Sensore rettangolare multicontatto nylon vetro autoestinguente 40 x 13Rectangular uninflammable multicontact nylon glass body sensor 40 x 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E524 . . . . . . . . . .Pag.24

Sensore rettangolare nylon vetro autoestinguente 65 x 20Rectangular uninflammable nylon glass body sensor 65 x 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E53H . . . . . . . . . .Pag.25

Sensore rettangolare nylon vetro autoestinguente 25 x 14Rectangular uninflammable nylon glass body sensor 25 x 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E541 . . . . . . . . . .Pag.26

Sensore di Direzione e Velocità ad effetto HALL rettangolare PPS nero autoestinguente 92 x 25Direction & Speed HALL Effect Sensor Rectangular uninflammable PPS black body 92 x 25 . . . . . . . . . . . . . . . . . . . . .E57H DV . . . . . . .Pag.27

Sensore rettangolare nylon vetro autoestinguente 120 x 18Rectangular uninflammable nylon glass body sensor 120 x 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E80H . . . . . . . . . .Pag.28

Distanze di attivazione fra magneti e sensori hallActivation distances between magnets and hall sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pag.29

Connettori e TerminaliConnectors and Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pag.31

La società STEM S.r.l. fu fondata nel 1987 ed iniziò la propria attività produttiva nel 1988 costruendo sensori ma-gnetici di prossimità e unità magnetiche. Attualmente la STEM è in grado di fornire anche una completa gamma diprodotti dedicati al sistema di controllo per ascensori, al controllo livello liquidi ed ai sistemi di sicurezza per l’indu-stria. Nel 2002 sono stati ultimati i lavori di ampliamento del nuovo stabilimento necessari per meglio favorire la cre-scita della produzione; l’utilizzo di nuove e più avanzate attrezzature garantisce un aumento della qualità dei nostriprodotti grazie ad un costante controllo. La qualità del prodotto STEM è inoltre garantita sia dal conseguimento del-la certificazione ISO 9002, rilasciata dalla DNV Italia nel 1997, sia dall’omologazione TÜV, rilasciata nel 2000, perquanto riguarda i sensori STEM della serie C e della serie E6 che possono essere utilizzati anche nei sistemi di sicu-rezza essendo conformi alla vigente normativa UNI EN 81-1/2.

Stem S.r.l. has been founded in 1987 and begun its productive activity in 1988 with the construction of ProximityMagnetic Sensors and Magnetic Units. The actual development of the production offers to own customers a greatchoice of models for Lift Control Systems, Liquid level control and Safety Systems for Industy. In 2002 have beencompleted the enlargement of the new factory that will better favour the increase of the production; The use of newand more advanced equipments, guarantee a constant manufacturing control and increase the quality of our sensors.The quality of STEM’s products is guaranteed by the ISO 9002 certification, released by DNV Italy in 1997, and byTÜV homologation released in year 2000. STEM’s series C and E600 models, are conform to the UNI EN 81-1/2standard and suitable to be used in safety systems circuits.

Page 3: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

3

Il principio dell’effetto HALL prende il nome

dal fisico Edwin Hall che nel 1879 scoprì che

quando un conduttore o un semiconduttore, at-

traversato da corrente, è inserito perpendicolar-

mente in un campo magnetico è possibile misu-

rare una differenza di potenziale ai capi dell’e-

lemento sensibile.

L’effetto HALL è un dispositivo di commuta-

zione elettronico the fornisce un segnale logico

PNP o NPN.

The principle of the HALL effect takes the namefrom the physicist Edwin Hall that in 1879 di-scovered that when a conductor or a semicon-ductor, crossed from a current, is perpendicu-larly introduced to a magnetic field it is possi-ble to measure a potential difference to the si-des of the sensitive element.The HALL effect is a switching electronic devi-ce that supply a signal with PNP or NPN logi-cal.

Questi sensori forniscono un segnale molto

preciso, ripetibile e veloce (microsecondi)

adatto ad essere usato con un microprocessore

od un PLC. Alcuni modelli sono forniti di LED

per indicare lo stato del sensore; il LED è VER-

DE per le versioni con uscita NPN e ROSSO

per quelle PNP; la luce è guidata all’esterno

tramite un tappo di chiusura trasparente.

Una delle più importanti caratteristiche di que-

sto sensore è l’elevata resistenza agli shock

meccanici, punto debole dei tradizionali senso-

ri magnetici a contatto reed.

Il tipo di segnale può essere monostabile o bi-

stabile e l’uscita NPN o PNP.

This sensors provides a signal that is very pre-cise, repeatable and quick (microseconds) sui-table to be used with a microprocessor or aPLC. Some models are provided with an LEDthat shows the sensor's status; this LED isGREEN for NPN output versions and RED forPNP ones; the light is guided-out through atransparent back cap. One of the most impor-tant features of this sensor is the very high resi-stance to the mechanical shocks, weak point ofthe traditional magnetic sensors made with areed contact. The signal type could be mono-stable or bistable and the output type NPN orPNP.

ASSI DI ATTIVAZIONE DEI SENSORI AD EFFETTO HALLHALL EFFECT SENSORS ACTIVATION AXIS

Page 4: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

4

Uso di un sensore di Hall con un magnete ad anello a magnetizzazione multipolare.

E’ possible misurare la velocità di rotazione o il numero di giri per un posizionamento.

Use of Hall sensor with a ring ma-gnet that have a multi-pole magneti-zation. It's possible to measure therotation speed or the number of rota-tion for a positioning.

MONOSTABLE: il segnale

è normalmente spento in

assenza di campo magneti-

co.

Il dispositivo si accende in

presenza di un polo magne-

tico SUD sufficientemente

intenso e si rispegne in sua

assenza.

BISTABILE: L’effetto Hall

permane nel suo stato di ac-

ceso o spento fino a quando

un polo magnetico opposto non è applicato. Un

polo magnetico SUD accende il dispositivo; es-

so rimane acceso fino a quando un polo magne-

tico NORD viene applicato.

MONOSTABLE: the switchis normally OFF in the ab-sence of a magnetic field.

The device turns ON in thepresence of a sufficientlystrong SOUTH magneticpole and turns OFF wi-thout it.BISTABLE: the hall effectremains in either state (out-put ON or OFF) until an

opposite pole magnet is applied. A South ma-gnetic pole turns the device ON; the device willstay ON until a North magnetic pole is applied.

Page 5: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

5

SEN

SOR

E M

AGN

ETIC

O L

INEA

RE

AD E

FFET

TO H

ALL

MAG

NET

IC L

INEA

R H

ALL

EFFE

CT S

ENSO

RE5

3H

Sensore Magnetico Lineare ad Effetto HALLMagnetic Linear HALL Effect Sensor

The linear Hall effect sensor provides an analog outputproportional to the magnetic field. Therefore, by placingthe sensor laterally with respect to a cylindrical magnetpolarized NORTH-SOUTH it will be possible themeasurement of the linear displacement of the same (Fig.1), or the rotation angle in the case of using a toroidalmagnet (Fig. 2).

The sensor activation with frontal magnet (sensing of onepolarity only), although possible, is not recommended asit would give up half of the available dynamic signal.

The output of the sensor, suitably elaborated could becurrent type 4-20 mA or voltage type 2V-9.6 V. When thesensor will be in correspondence with the area in zeromagnetic field (the junction area between the north-southpolarity), the output signal will be in the center dynamics(for example in the case current output 16mA), while atthe ends of the magnet will reach the maximum and theminimum of its signal (4mA-20mA).

The maximum measurable displacement is proportional tothe size and type of the magnet (ferrite, neodymium,alnico ..) as well as to the distance between magnet andsensor, indicatively is possible to measure a maximumdisplacement of about 40-45mm with a good resolution.

Each sensor can be calibrated to ensure maximumrepeatability of the measure in function of thedisplacement and the temperature of the system. Ifrequested, it is also possible to obtain a linearization of theoutput curve, thanks to a special procedure for the signalconditioning. Stem offers a support service for systemdesign and for sensor calibration in production accordingto the customer specifications.

The main applications of the system are:

- Valves positioning (hydraulic and pneumatic)- Axes, positioning- Level sensors- Short linear shifts in general

Il sensore ad effetto hall lineare fornisce un’uscitaanalogica proporzionale al campo magnetico.Pertanto posizionando il sensore lateralmente rispetto adun magnete cilindrico polarizzato NORD-SUD si potràmisurare lo spostamento lineare dello stesso (fig.1),oppure un’ angolo di rotazione nel caso si utilizzi unmagnete toroidale (fig.2).

L’attivazione del sensore con magnete frontale (sensing diuna sola polarità), sebbene possibile, non è consigliabilein quanto si rinuncerebbe a metà della dinamica disegnale disponibile.

L’uscita del sensore, opportunamente condizionata puòessere in corrente 4-20ma oppure in tensione 2V-9,6V.Quando il sensore si troverà in corrispondenza della zonaa campo magnetico nullo (zona di giunzione tra le polaritàNORD-SUD), il segnale di uscita si troverà a centrodinamica (ad esempio 16 mA nel caso di uscita incorrente), mentre alle estremità del magnete siraggiungeranno il massimo ed il minimo del suo segnale(4mA-20mA).

Il massimo spostamento misurabile è proporzionale alladimensione ed al tipo di magnete (ferrite, neodimio,alnico..) nonché alla distanza tra magnete e sensore,indicativamente è possibile misurare uno spostamentomassimo di circa 40-45mm con una buona risoluzione.

Ogni sensore può essere calibrato in modo da garantire lamassima ripetibilità della misura in funzione dellospostamento e della temperatura del sistema. Su esplicitarichiesta è inoltre possibile ottenere una linearizzazionedella curva di uscita, grazie ad una particolare proceduradi condizionamento del segnale. A tal proposito Stemoffre un servizio di supporto sia in fase di progettazioneche per la calibrazione dei lotti di produzione secondo lespecifiche del cliente.

Le principali applicazioni del sistema sono:

- Posizionamento valvole idrauliche e pneumatiche- Posizionamento assi- Sensori di livello- Piccoli spostamenti lineari in genere

Page 6: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

6

SENS

ORE

AD E

FFET

TO H

ALL

LINE

ARE

HAL

L EF

FECT

LIN

EAR

SENS

ORS

PRINCIPIO DI MISURA

Il sensore sfrutta il principio fisico scoperto da Edwin Hall,per il quale sulle facce opposte di un conduttore elettrico,attraversato da corrente, e sottoposto ad un campomagnetico si sviluppa una differenza di potenzialeproporzionale all’intensità del campo magnetico.

Pertanto assemblando un magnete sulla parte inmovimento e mantenendo fisso il sensore si riesce amisurare con un’ottima risoluzione (<2/10 mm), lospostamento lineare della parte meccanica.L’uscita in corrente 4-20 mA proporzionale allospostamento garantisce una buona immunità al rumore.Il sensore è inoltre dotato di una uscita di errore chesegnala la mancata connessione della resistenza dimisura oppure la connessione di una resistenza di valorenon adeguato.

Il massimo spostamento misurabile è proporzionale alladimensione ed al tipo di magnete (ferrite, neodimio,alnico...) nonché alla distanza tra magnete e sensore.Ogni sensore può essere calibrato in modo da garantire lamassima ripetibilità della misura in funzione dellospostamento e della temperatura del sistema.A tal proposito Stem offre un servizio di supporto sia infase di progettazione che per la calibrazione dei lotti diproduzione secondo le specifiche del cliente.

PRINCIPALI BENEFIT DEL SISTEMA DI MISURA

• Sistema di misura senza contatto con la parte in movimento

• Misura di oggetti in movimento all’interno di parte plastiche o metalliche chiuse (non ferromagnetiche)

• Uscita analogica lineare 4-20 mA• Elevata sensibiltà • Grado di protezione IP67• Possibilità di linearizzare la curva di misura durante

la fase di calibrazione

PRINCIPALI APPLICAZIONI DEL SISTEMA

• Posizionamento valvole idrauliche e pneumatiche• Posizionamento assi • Sensori di livello• Spostamenti lineari in genere

WORKING PRINCIPLE

The sensor is based on the physical principle discoveredby Edwin Hall, for which on the opposite faces of theelectrical conductor, where current flows through, andsubjected to a magnetic field develops a differentialvoltage proportional to the intensity of the magnetic field.

Therefore assembling a magnet on the moving part andkeeping fixed the sensor it is possible to measure withgood resolution (<2/10 mm) the linear displacement of themovement part.The current output 4-20 mA proportional to thedisplacement ensures good noise immunity.The sensor is also equipped with an error output, tosignals the connection failure of the measurementresistance or a connection to a wrong resistance value.

The maximum measurable displacement is proportional tothe size and type of magnet (ferrite, neodymium, alnico ..)as well as to the distance between magnet and sensor.Each sensor can be calibrated to ensure maximumrepeatability of the measure in function of thedisplacement and the temperature of the system. Stemoffers a support service for system design and for sensorcalibration in production according to the customerspecifications.

MAIN BENEFIT OF THE MEASURING SYSTEM

• Measuring system without contact with the moving part

• Measurement of moving objects enclosed in a metal or plastics part (not ferromagnetic)

• Linear analogue output 4-20 mA• High sensitivity• Protection Degree IP67• Possibility to obtain a linear measurement curve

during the calibration phase

MAIN SYSTEM APPLICATIONS

• Hydraulic and pneumatic valve positioning• Axis positioning• Level sensors• General Linear displacement

Sensore Magnetico Lineare ad Effetto HALLSE

NSO

RE

MAG

NET

ICO

LIN

EAR

E AD

EFF

ETTO

HAL

LM

AGN

ETIC

LIN

EAR

HAL

L EF

FECT

SEN

SOR

E53H

Page 7: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

7

SENS

ORE

AD E

FFET

TO H

ALL

LINE

ARE

HAL

L EF

FECT

LIN

EAR

SENS

ORS

GRAFICI CURVE USCITA

Le curve di uscita sono strettamente dipendenti dal tipo dimagnete utilizzato, dalle sue dimensioni e dalla distanza

*1FSO = full scale output

OUTPUT CURVES

The output curves are strictly dependent on the type ofmagnet used, its size and the distance between sensorand magnet

DATI TECNICI / TECHNICAL DATA

Tensione di alimentazione / Power supply 10 - 30 VDC

Corrente massima assorbita senza carico /Maximum current consumption without load(Vsupply 30V)

28 mA

Uscita di segnalazione guasto in caso di caricosconnesso o resistenza troppo elevata / fault outputactive if load resistance not present or loadresistance too high

Open collector PNP Imax 100 mAVmax 30 V

Uscita in corrente proporzionale allo spostamentodel magnete / Linear output current

Min 4 mA +/- 0,5 mAMax 20 mA +/- 0,5 mA

Tempo di risposta dal 10% FSO*1 al 90% FSOResponse time from 10% FSO*1 al 90% FSO

1ms

Risoluzione misurabile sullo spostamento delmagnete/ Linear Displacement Resolution

0,2 mm

Risoluzione uscita lineare / Linear output resolution <0,5 % FSO

Dimensione dispositivo sensoreMechanical dimensions

65 H x 20 W x 9 T (mm)

Limiti di temperatura operativeOperating temperature range

-30°C + 105°C

Limiti di temperatura di immagazzinamentoStorage temperature range

-30°C + 105°C

Classe di protezione / Protection class IP67

Conformità test EMCEMC Compliance

EN 61326-1: 2006, EN61000-6-2: 2006,EN61000-6-3: 2007, EN 61326-2-3: 2006

Magnetic Linear HALL Effect Sensor

SEN

SOR

E M

AGN

ETIC

O L

INEA

RE

AD E

FFET

TO H

ALL

MAG

NET

IC L

INEA

R H

ALL

EFFE

CT S

ENSO

RE5

3H

Page 8: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

Sensore effetto HALL diam. 8Cylindrical Hall-Effect sensor diam. 8

Corpo sensore in PPS neroUninflammable PPS black body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

A08H NEROBlack MN N.O. Contatto normalmente aperto uscita tipo: NPN

Normally open contact output type: NPN TB 4,4 0,35 tripolare neroblack tripolar

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Caratteristiche tecnicheTechnical features

A08H MN TB 0 140 A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max25 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY8

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

A08H

Page 9: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

9

Sensibilità - Sensibility

Sensore effetto HALL semifilettato M12x1Half-threaded M12x1 Hall Effect sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

C12H CN TB 0 140 M L A

Esempio di sigla di ordinazioneOrder code example

Caratteristiche tecnicheTechnical features

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C12H BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contactoutput type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C12H BLUBlue

CN N.C. Contatto normalmente chiuso tipo: NPNNormally closed contact type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / CableMemoriaMemorySerie

SeriesColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C12H BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar M

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

M = MEMORIA (SOLO PER VERSIONI BISTABILI) BIST. SENZA MEM. = -M = MEMORY (ONLY FOR BISTABLE VERSION) BIST. WITHOUT MEM. = -

L = LED; - = NO LED;L = LED; - = NO LED;

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 27 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

C12H

Page 10: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

10

Sensore effetto HALL diam. 12Cylindrical Hall-Effect sensor diam. 12

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Versioni multicontatto a richiesta Multicontact models on request

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C15H BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C15H BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / CableMemoriaMemorySerie

SeriesColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C15H BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar M

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 27 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche tecnicheTechnical features

C15H CN TB 0 140 M L A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

L = LED; - = NO LED;L = LED; - = NO LED;

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

C15H

M = MEMORIA (SOLO PER VERSIONI BISTABILI) BIST. SENZA MEM. = -M = MEMORY (ONLY FOR BISTABLE VERSION) BIST. WITHOUT MEM. = -

Page 11: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

11

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C19H BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C19H BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo: NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo: PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / CableMemoriaMemorySerie

SeriesColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

C19H BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar M

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI CON MEMORIA / BISTABLE SENSORS WITH MEMORY

Sensore effetto HALL filettato M12x1Threaded M12x1 Hall Effect sensor

Caratteristiche tecnicheTechnical features

C19H CN TB 0 140 M L A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

L = LED; - = NO LED;L = LED; - = NO LED;

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 27 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

C19H

M = MEMORIA (SOLO PER VERSIONI BISTABILI) BIST. SENZA MEM. = -M = MEMORY (ONLY FOR BISTABLE VERSION) BIST. WITHOUT MEM. = -

Page 12: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

12

Sensore effetto HALL cilindrico diam. 8Cylindrical Hall-Effect sensor diam. 8

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D08P BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D08P BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D08P BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Caratteristiche tecnicheTechnical features

D08P CN TB 0 140 A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D08P

Page 13: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

13

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D10P BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D10P BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo: NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo: PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D10P BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Sensore effetto HALL filettato M10x0,75Threaded M10x0,75 Hall Effect sensor

Caratteristiche tecnicheTechnical features

D10P CN TB 0 140 L A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

L = LED; - = NO LED;L = LED; - = NO LED;

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 27 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D10P

Page 14: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

14

Sensore effetto HALL diam. M12x1Cylindrical Hall-Effect sensor diam. M12x1

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D12P BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D12P BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D12P BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Caratteristiche tecnicheTechnical features

D12P CN TB 0 140 L A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

L = LED; - = NO LED;L = LED; - = NO LED;

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 27 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D12P

Page 15: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

15

Corpo sensore in Ottone nichelatoUninflammable Nickel-brass body sensor

Sensore effetto HALL filettato M10x0,75Threaded M10x0,75 Hall Effect sensor

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

TensioneVoltage

V

PotenzaPower

W

CorrenteCurrent

A

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

D101 SA 4,5 - 24 100 max 50 mA TE 5 0,5 TRIPOLARE NEROBLACK TRIPOLAR S

EN

SO

RI

AD

EF

FE

TT

O H

AL

LH

AL

L E

FF

EC

T S

EN

SO

RD1

01

Caratteristiche tecnicheTechnical features

D101 SA TE 0 198

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

Frequenza di manovra1 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max50 mA

Maximum output current

Grado di protezioneIP 55

Degree of protection

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

Page 16: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

16

Sensore effetto HALL diam. M12x1Cylindrical Hall-Effect sensor diam. M12x1

Corpo sensore in Ottone NichelatoNickel Brass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D123

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D123

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D123

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Caratteristiche tecnicheTechnical features

D123 CN TB 0 140 A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D123

Page 17: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

17

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D125

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D125

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D125

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Caratteristiche tecnicheTechnical features

D125 CN TB 0 140 A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

Sensore Effetto HALL Cilindrico Filettato M12x1Cylindrical Treaded Hall-Effect Sensor diam. M12x1

Corpo sensore in Ottone NichelatoNickel Brass body sensor

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D125

Page 18: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

Sensore Effetto HALL Cilindrico Filettato M12x1 con connettoreCylindrical Treaded Hall-Effect Sensor diam. M12x1 with connector

Corpo sensore in Ottone NichelatoNickel Brass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact

SerieSeries

ContattoContact

Tipo di contattoContact Type

D125 MB N.O.Contatto normalmente aperto uscita tipo:

NPN e PNPNormally open contact output type:

NPN and PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact

SerieSeries

ContattoContact

Tipo di contattoContact Type

D125 BB BiContatto bistabile uscita tipo:

NPN e PNPNormally bistable output type:

NPN and PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI BISTABILI / BISTABLE SENSORS

Caratteristiche tecnicheTechnical features

D125 MB 00 3404 A x

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

CARATTERISTICHE SPECIALISPECIAL FEATURES

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

18

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D125

Page 19: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

Sensore Effetto HALL Cilindrico Filettato M12x1Cylindrical Treaded Hall-Effect Sensor diam. M12x1

Corpo sensore in Ottone NichelatoNickel Brass body sensor

19

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D128 BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D128 BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

D128 BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Caratteristiche tecnicheTechnical features

D128 CN TB 0 140 A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D128

Page 20: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

20

Sensore Cilindrico Filettato M12x1 per Ruote Dentate Cylindrical Treaded Gear Tooth Sensor diam. M12x1

Il sensore ad Effetto HALL D16H si attiva in prossimitàdi ogni dente dell’ingranaggio.

The Hall effect sensor D16H is activated in closeproximity to each tooth of the gear.

Corpo sensore in Ottone NichelatoNickel Brass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Schema di collegamentoConnection Scheme

CorpoBody Contatto / Contact Cavo / Cable

SerieSeries

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

D16H TN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN TB 4,4 0,35 tripolare nero

black tripolar

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Caratteristiche tecnicheTechnical features

D16H TN TB 0 140

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

Resistenza agli urti30 g / 11 ms

Impact Resistance

Resistenza alle vibrazioni0,35 mm 10-55 Hz

Impact Resistance

Temperatura di lavoro-40° C ... +90° C

Working Temperature

Tensione di alimentazione (Vs)12 Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Corrente di uscita max20 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Frequenza di manovraOperation frequency 12000 rpm MAX

conSPECIFICHE INGRANAGGIO

GEAR SPECIFICATIONS

Diametro / Diameter 120 mmSpessore / Thickness 6 mm

Spessore dente / Tooth width 3 mmSpessore gola / Valley width 3 mm

Profondità gola / Valley depth 3 mmMateriale / Material Low Carbon Steel

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

D16H

Page 21: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

21

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

E512

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E512 BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E512 BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo: NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo: PNPNormally closed contact output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Sensore effetto HALL rettangolareRectangular Hall Effect sensor

Caratteristiche tecnicheTechnical features

E512 CN TB 0 140 Y/Z V24 A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

ASSI DI ATTIVAZIONE DISPONIBILIAVAILABLE ACTIVATION AXES

V24 = MAX TENSIONE ALIMENTAZIONE 24 Vdc;V27 = MAX TENSIONE ALIMENTAZIONE 27 Vdc;V24 = MAX SUPPLY VOLTAGE 24 Vdc;V27 = MAX SUPPLY VOLTAGE 27 Vdc;

Assi di AttivazioneActivation Axis

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs) 9 ÷ 24 ± 10% VdcSupply Voltage (Vs) 9 ÷ 27 ± 10% Vdc

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITYSENSIBILITÀ (VEDI TABELLA): A, DSENSIBILITY (SEE TABLE BESIDE): A, D

Page 22: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

22

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E514 BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Sensore effetto HALL rettangolarecon attivazione centraleRectangular Hall Effect sensorwith central activation

Caratteristiche tecnicheTechnical features

E514 MN TB 0 140 Y/Z A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

ASSI DI ATTIVAZIONE DISPONIBILIAVAILABLE ACTIVATION AXES

POSSIBILITÀ DI ATTIVAZIONI DISPONIBILIAVAILABLE ACTIVATION POINT

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max 01 = 25 mAMaximum output current 02 = 100 mA

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

E514

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SENSIBILITÀ (VEDI TABELLA): A, DSENSIBILITY (SEE TABLE BESIDE): A, D

Sensibilità - Sensibility

Page 23: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

23

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

E522

Sensore effetto HALL rettangolareRectangular Hall Effect sensor

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E522 BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E522 BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo:NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo:PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E522 BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Caratteristiche tecnicheTechnical features

Esempio di sigla di ordinazioneOrder code example

E522 CN TB 0 140 X/Y/Z V24 A

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

ASSI DI ATTIVAZIONE DISPONIBILIAVAILABLE ACTIVATION AXES

V24 = MAX TENSIONE ALIMENTAZIONE 24 Vdc; V27 = MAX TENSIONE ALIMENTAZIONE 27 Vdc;V24 = MAX SUPPLY VOLTAGE 24 Vdc; V27 = MAX SUPPLY VOLTAGE 27 Vdc;

Assi di AttivazioneActivation Axes

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs) 9 ÷ 24 ± 10% VdcSupply Voltage (Vs) 9 ÷ 27 ± 10% Vdc

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Page 24: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

24

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

E524

Sensore effetto HALL rettangolare multicontattoRectangular Hall Effect multicontact sensor

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

AttivazioneContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E524 BLUBlue

S1S2 N.O. Contatto normalmente aperto uscita tipo: NPN

Normally open contact output type: NPN TB 4,4 0,35 tripolare neroblack tripolar

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

AttivazioneContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

E524 BLUBlue S3 N.O. Contatto normalmente aperto uscita tipo: NPN

Normally open contact output type: NPN NA 5 0,35

quadripolareneroblack

quadipolar

Caratteristiche tecnicheTechnical features

Esempio di sigla di ordinazioneOrder code example

E524 S1 TB 0 140 Y/Z A

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

ASSI DI ATTIVAZIONE DISPONIBILIAVAILABLE ACTIVATION AXES

POSSIBILITÀ DI ATTIVAZIONI DISPONIBILIAVAILABLE ACTIVATION POINT

CODICE / CODE ATTIVAZIONI / ACTIVATIONS SEGNALE DI USCITA / OUTPUT SIGNAL

S1 2 Singolo / Single

S2 1 - 3 Singolo / Single (1 OR 3)

S3 1 - 3 Separati / Separated

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SENSIBILITÀ (VEDI TABELLA): A, M, DSENSIBILITY (SEE TABLE BESIDE): A, M, D

Page 25: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

25

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

E53H

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI BISTABILI / BISTABLE SENSORS

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E53H BLUBlue

MN N.O. Contatto normalmente aperto uscita tipo: NPNNormally open contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

MP N.O. Contatto normalmente aperto uscita tipo: PNPNormally open contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E53H BLUBlue

CN N.C. Contatto normalmente chiuso uscita tipo: NPNNormally closed contact output type: NPN

TB 4,4 0,35 tripolare neroblack tripolar

CP N.C. Contatto normalmente chiuso uscita tipo: PNPNormally closed contact output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E53H BLUBlue

BN Bi Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TC 4,4 0,35 tripolare grigiogrey tripolar

BP Bi Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

SENSORI MONOSTABILI N.C. / MONOSTABLE SENSORS N.C.

Sensore effetto HALL rettangolareRectangular Hall Effect sensor

Caratteristiche tecnicheTechnical features

E53H CN TB 0 140 X/Y/Z L A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

ASSI DI ATTIVAZIONE DISPONIBILIAVAILABLE ACTIVATION AXES

L = LED; - = NO LED;L = LED; - = NO LED;

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Sensibilità - Sensibility

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

BASSA - POLARITÀ SUDM =

LOW - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITYSENSIBILITÀ (VEDI TABELLA): A, M, D (SOLO PER VERSIONE MONOSTABILE)SENSIBILITY (SEE TABLE BESIDE): A, M, D (ONLY FOR MONOSTABLE VERSION)

Page 26: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

26

Sensore effetto HALL rettangolareRectangular Hall Effect sensor

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E541 BLUBlue MN N.O. Contatto normalmente aperto uscita tipo: NPN

Normally open contact output type: NPN TB 4,4 0,35 tripolare neroblack tripolar

SENSORI MONOSTABILI N.O. / MONOSTABLE SENSORS N.O.

Caratteristiche tecnicheTechnical features

E541 MN TB 0 140 Z A

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

ASSI DI ATTIVAZIONE DISPONIBILIAVAILABLE ACTIVATION AXES

Frequenza di manovra10 KHz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Corrente di uscita max60 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

Sensibilità - Sensibility

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

ALTA - POLARITÀ SUDA =

HIGH - SOUTH POLARITY

ALTA - POLARITÀ NORD e SUDD =

HIGH - NORTH & SOUTH POLARITY

SE

NS

OR

I A

D E

FF

ET

TO

HA

LL

HA

LL

EF

FE

CT

SE

NS

OR

E541

SENSIBILITÀ (VEDI TABELLA): A, DSENSIBILITY (SEE TABLE BESIDE): A, D

Page 27: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

27

Corpo sensore in PPS Nero autoestinguenteUninflammable PPS Black body sensor

Sensore di Direzione e Velocità ad Effetto HALLDirection & Speed Hall Effect Sensor

SE

NS

OR

E D

I D

IRE

ZIO

NE

E V

EL

OC

ITÀ

DIR

EC

TIO

N &

SP

EE

D S

EN

SO

RE5

7H D

V

Schema di collegamentoConnection Scheme Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

E57H NEROBlack DV

OUT 1 - OUT 2 - OUT 3 - OUT 4

Contatto MONOSTABILE uscita tipo:NPN o PNP

MONOSTABLE contact output type:NPN o PNP

EE 5,8 6 x AWG24 esapolare grigiogrey esapolar

Caratteristiche tecnicheTechnical features

E57H DV EE P 140 PP 1S

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

PP = USCITA PNP / NN = USCITA NPNPP = OUTPUT PNP / NN = OUTPUT NPN

- = TIMEOUT OUT1 - OUT2 5 sec.1S = TIMEOUT OUT1 - OUT2 1 sec.

Frequenza di manovra100 Hz

Operation frequency

Tensione di alimentazione (Vs)9 ÷ 27 +1 -10% Vdc

Supply Voltage (Vs)

Temperatura di lavoro-30° C ... +85° C

Working Temperature

Tensione di uscita tipo NPN0 Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs

Output Voltage Type PNP

Corrente di uscita max100 mA

Maximum output current

Grado di protezioneIP 67 (IEC 60529)

Degree of protection

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

Applicazione del sistema / System application• Tramite le uscite OUT1 (LED rosso) e OUT2 (LED verde) è possibile monitorare la direzione della parte in movimento

• Using the outputs OUT1 (RED LED), OUT2 (GREEN LED) it's possible to check the direction of the movement part• Tramite le uscite OUT3 e OUT4 è possibile calcolare l'informazione di velocità come indicato sotto.

• Using the output OUT3 and OUT4 a speed information can be calculated using the below formula.

DIREZIONE 1 / DIRECTION 1 USCITE PNP *2 / PNP OUTPUTS *2 DIREZIONE 2 / DIRECTION 2

V [m/s] = 0,03/t

*2 in caso di uscite NPN la polarità dei segnali è invertita *2 in case of NPN outputs, signal polarity is reversed

Page 28: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

28

Sensore effetto HALL rettangolareRectangular Hall Effect sensor

Corpo sensore in nylon vetro autoestinguenteUninflammable nylon glass body sensor

SEN

SOR

E BI

STAB

ILE

MEC

CAN

ICO

ad

EFFE

TTO

HAL

LM

ECH

ANIC

AL B

ISTA

BLE

HAL

L EF

FECT

SEN

SOR

E80H

Caratteristiche tecnicheTechnical features

Esempio di sigla di ordinazioneOrder code example

SERIESERIES

TIPO CONTATTOCONTACT TYPE

TIPO CAVOCABLE TYPECARATTERISTICHE CABLAGGIOWIRING FEATURES

LUNGHEZZA IN cmLENGHT IN cm

Caratteristiche CablaggioWiring Features

0 = STANDARD (COME DISEGNO)STANDARD (LIKE DRAW)

P = PUNTALINICONNECTORS

SENSORI BISTABILI / BISTABLE SENSORS

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

MARRONEBrown

BLUBlue

NEROBlack

E80H NEROBlack

BN

Bi

Contatto bistabile uscita tipo: NPNNormally bistable output type: NPN

TP 4,4 0,35tripolaregrigio

grey tripolarBP Contatto bistabile uscita tipo: PNPNormally bistable output type: PNP

Schema di collegamentoConnection Scheme

Corpo / Body Contatto / Contact Cavo / Cable

SerieSeries

ColoreColour

ContattoContact

Tipo di contattoContact Type

CavoCable

DiametroDiameter

mm

ConduttoriConductors

mm2

CaratteristicheFeatures

E80H NEROBlack BR Bi

RELAY DI SCAMBIO

CHANGE-OVER RELAYTP 4,4 0,35

tripolaregrigio

grey tripolar

E80H BN TP 0 140BN - BP BR

Frequenza di manovramax 5 Hz max 5 Hz

Operation frequency

Temperature di esercizio-25° C ... +85 °C -30° C ... +85 °C

Degree of protection

Potenza massima dissipata900 mW 1,2 W

Max power dissipation

Tensione di alimentazione (Vs)5 ÷ 24 ± 10% Vdc 5 ÷ 24 ± 10% Vdc

Supply Voltage (Vs)

Tensione di uscita tipo NPNVdc Vdc

Output Voltage Type NPN

Tensione di uscita tipo PNPVs Vs

Output Voltage Type PNP

Corrente di uscita max100 mA 1 A

Maximum output current

Grado di protezioneIP 55 (IEC 60529)

Degree of protection

Page 29: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

29

D 1 = distanze massime di intervento al bordo (mm)

D 2 = distanze massime di intervento al centro (mm)

D 1 = maximum operating distances to the edge (mm)

D 2 = maximum operating distances to the center (mm)

CONTATTO

Plastoferrite (dimensioni in mm)

CONTACT

Plastoferrite (dimensions in mm)

60 x 20 x 6 80 x 20 x 6 80 x 20 x 12

ON OFF ON OFF ON OFF

BD 25 25 31 31 35 35

CONTATTO

Plastoferrite (dimensioni in mm)

CONTACT

Plastoferrite (dimensions in mm)

150 x 15 x 6 200 x 15 x 6 150 x 20 x 6 150 x 15 x 8

D 1 D 2 D 1 D 2 D 1 D 2 D 1 D 2

NO 28 38 27 35 29 40 29 37

DISTANZE DI ATTIVAZIONE FRA MAGNETI E SENSORI HALLACTIVATION DISTANCES BETWEEN MAGNETS

AND HALL SENSORS

PLASTOFERRITE / PLASTOFERRITE

Sensori monostabili / Monostable sensors

Sensori bistabili / Bistable sensors

Distanze massime di intervento (mm).

Maximum operating distances (mm).

Page 30: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

30

Monostabile / MonostableLATO SUD (ON)Consente l’attivazioneSOUTH POLE (ON)Activation allowed

Bistabile / BistableLATO SUD (ON)SOUTH POLE (ON)

LATO NORD (OFF)NORTH POLE (OFF)

DISTANZE DI ATTIVAZIONE FRA MAGNETI E SENSORI HALLACTIVATION DISTANCES BETWEEN MAGNETS AND HALL SENSORS

FERRITE E NEODIMIO / FERRITE AND NEODYM

Distanze massime di intervento / Maximum operating distances

Di seguito riportiamo le distanze di attivazione per i sensori adeffetto Hall monostabili e bistabili con magneti in ferrite e neo-dimio di varie forme e dimensioni. I monostabili si attivano so-lo con la polarità SUD dei magneti; i bistabili si attivano conpolarità SUD e si disattivano con polarità NORD.

Following we report the activation distances for the Hall effectsensors, monostables and bistables, with ferrite and neodymmagnets of different shapes and dimensions. Monostables areactivated only with SOUTH polarity; bistables are activatedwith SOUTH polarity and deactivated with NORTH polarity.

MAGNETENO MONOSTABILE BISTABILE

MAGNETNO MONOSTABLE BISTABLE

D mm D ON/OFF mm

MF A020 004 010Ferrite / Ferrite

32 35

MF P020 014 012Ferrite / Ferrite

30 32

MF P026 017 008Ferrite / Ferrite

34 35

MF P032 020 010Ferrite / Ferrite

40 43

MF P040 016 008Ferrite / Ferrite

38 41

MF DIAM 028 005Ferrite / Ferrite

33 33

MF AZ23 Z04 010Ferrite / Ferrite

35 36

MN DIAM 018 003Neodimio / Neodym

36 37

MN DIAM 018 005Neodimio / Neodym

41 44

MN DIAM 020 003Neodimio / Neodym

38 40

M613 FC GB A000Ferrite / Ferrite

17 17

M613 NC GB A000Neodimio / Neodym

27 26

Per le dimensioni vedere pag. 49. For dimensions consult page 49.

Page 31: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

31

CONNETTORI E TERMINALICONNECTORS AND TERMINALS

La STEM è in grado di fornire sensori con terminali e connetto-

ri di vario tipo a seconda delle esigenze del cliente; sono anche

disponibili precablaggi di uno o più sensori su morsetti a vite

secondo le diverse combinazioni di utilizzo.

STEM is suitable to supply sensors with varied terminals andconnectors according to the customer’s requests; one or moresensors prewiring on plug-in screw terminals are alsoavailable for different sensors combinations.

Page 32: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

AnnotazioniAnnotazioniNotesNotes

Page 33: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

AnnotazioniAnnotazioniNotesNotes

Page 34: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

Impaginazione STEM S.r.l.Stampato presso la Tipografia Commerciale Pavese - Pavia

Edizione stampata nel mese di Novembre 2013

Page 35: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

INDICE / INDEXSensori ad effetto hall / Hall effect sensors

Assi di attivazione dei sensori ad effetto hallHall effect sensors activation axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pag.3

Sensore Magnetico Lineare ad Effetto HALLCylindrical Magnetic Linear Hall-Effect Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E53H . . . . . . . . . .Pag.5

Sensore Cilindrico diam. 8 in PPS neroCylindrical uninflammable PPS Black body sensor diam. 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A08H . . . . . . . . . .Pag.8

Sensore semifilettato M12x1 nylon vetro autoestinguenteHalf-Threaded M12x1 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C12H . . . . . . . . . .Pag.9

Sensore cilindrico diam.12 nylon vetro autoestinguenteCylindrical diam.12 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C15H . . . . . . . . . .Pag.10

Sensore filettato M12x1 nylon vetro autoestinguenteThreaded M12x1 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C19H . . . . . . . . . .Pag.11

Sensore filettato M8x0,75 nylon vetro autoestinguenteThreaded M8x0,75 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D08P . . . . . . . . . .Pag.12

Sensore filettato M10x0,75 nylon vetro autoestinguenteThreaded M10x0,75 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D10P . . . . . . . . . .Pag.13

Sensore filettato M12x1 nylon vetro autoestinguenteThreaded M12x1 uninflammable nylon glass body sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D12P . . . . . . . . . .Pag.14

Sensore Cilindrico filettato M10x1 in ottone nichelatoCylindrical Threaded M10x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D101 . . . . . . . . . .Pag.15

Sensore Cilindrico filettato M12x1 in ottone nichelatoCylindrical Threaded M12x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D123 . . . . . . . . . .Pag.16

Sensore Cilindrico filettato M12x1 in ottone nichelatoCylindrical Threaded M12x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D125 . . . . . . . . . .Pag.17

Sensore Cilindrico filettato M12x1 in ottone nichelato con connettoreCylindrical Threaded M12x1 nickel-brass sensor with connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D125 . . . . . . . . . .Pag.18

Sensore Cilindrico filettato M12x1 in ottone nichelatoCylindrical Threaded M12x1 nickel-brass sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D128 . . . . . . . . . .Pag.19

Sensore Cilindrico filettato M12x1 in ottone nichelato per Ruote DentateCylindrical Threaded M12x1 Gear Tooth nickel-brass Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D16H . . . . . . . . . .Pag.20

Sensore rettangolare nylon vetro autoestinguente 36 x 13Rectangular uninflammable nylon glass body sensor 36 x 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E512 . . . . . . . . . .Pag.21

Sensore rettangolare nylon vetro autoestinguente 36 x 13 con attivazione centraleRectangular uninflammable nylon glass body sensor 36 x 13 with central activation . . . . . . . . . . . . . . . . . . . . . . . . . . . .E514 . . . . . . . . . .Pag.22

Sensore rettangolare nylon vetro autoestinguente 40 x 13Rectangular uninflammable nylon glass body sensor 40 x 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E522 . . . . . . . . . .Pag.23

Sensore rettangolare multicontatto nylon vetro autoestinguente 40 x 13Rectangular uninflammable multicontact nylon glass body sensor 40 x 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E524 . . . . . . . . . .Pag.24

Sensore rettangolare nylon vetro autoestinguente 65 x 20Rectangular uninflammable nylon glass body sensor 65 x 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E53H . . . . . . . . . .Pag.25

Sensore rettangolare nylon vetro autoestinguente 25 x 14Rectangular uninflammable nylon glass body sensor 25 x 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E541 . . . . . . . . . .Pag.26

Sensore di Direzione e Velocità ad effetto HALL rettangolare PPS nero autoestinguente 92 x 25Direction & Speed HALL Effect Sensor Rectangular uninflammable PPS black body 92 x 25 . . . . . . . . . . . . . . . . . . . . .E57H DV . . . . . . .Pag.27

Sensore rettangolare nylon vetro autoestinguente 120 x 18Rectangular uninflammable nylon glass body sensor 120 x 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E80H . . . . . . . . . .Pag.28

Distanze di attivazione fra magneti e sensori hallActivation distances between magnets and hall sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pag.29

Connettori e TerminaliConnectors and Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pag.31

La società STEM S.r.l. fu fondata nel 1987 ed iniziò la propria attività produttiva nel 1988 costruendo sensori ma-gnetici di prossimità e unità magnetiche. Attualmente la STEM è in grado di fornire anche una completa gamma diprodotti dedicati al sistema di controllo per ascensori, al controllo livello liquidi ed ai sistemi di sicurezza per l’indu-stria. Nel 2002 sono stati ultimati i lavori di ampliamento del nuovo stabilimento necessari per meglio favorire la cre-scita della produzione; l’utilizzo di nuove e più avanzate attrezzature garantisce un aumento della qualità dei nostriprodotti grazie ad un costante controllo. La qualità del prodotto STEM è inoltre garantita sia dal conseguimento del-la certificazione ISO 9002, rilasciata dalla DNV Italia nel 1997, sia dall’omologazione TÜV, rilasciata nel 2000, perquanto riguarda i sensori STEM della serie C e della serie E6 che possono essere utilizzati anche nei sistemi di sicu-rezza essendo conformi alla vigente normativa UNI EN 81-1/2.

Stem S.r.l. has been founded in 1987 and begun its productive activity in 1988 with the construction of ProximityMagnetic Sensors and Magnetic Units. The actual development of the production offers to own customers a greatchoice of models for Lift Control Systems, Liquid level control and Safety Systems for Industy. In 2002 have beencompleted the enlargement of the new factory that will better favour the increase of the production; The use of newand more advanced equipments, guarantee a constant manufacturing control and increase the quality of our sensors.The quality of STEM’s products is guaranteed by the ISO 9002 certification, released by DNV Italy in 1997, and byTÜV homologation released in year 2000. STEM’s series C and E600 models, are conform to the UNI EN 81-1/2standard and suitable to be used in safety systems circuits.

Page 36: Magnetic Hall-Effect Linear Position Sensor Magnetic Hall-Effect … · TCP Pavia - ed. 11/13 HALL Effect Sensors Magnetic Hall-Effect Switches Magnetic Hall-Effect Linear Position

STEM s.r.l.Sede Legale, Uffici e Stabilimento:

27010 Cura Carpignano PaviaVia della Meccanica, 2Zona Industriale Prado

ITALYTel. +39 0382.583011Fax +39 0382.583058e-mail: [email protected]://www.stemsrl.it

TCP

Pavi

a - e

d. 1

1/13

HALL EffectSensors

Magnetic Hall-Effect SwitchesMagnetic Hall-Effect Linear Position Sensor